™ Pipe Hangers Supports Seismic Bracing UL Listed for Fire Sprinkler Installations TOLCO™ is a brand of TOLCO™ Fire Protection Support Systems Supporting the Flow. www.tolco.com Revision 5/24/2001 a brand of Catalog Forward Warning This catalog has been created with an acute awareness of the field problems of the piping contractor. We have sought and received input from engineers, installers, field inspectors and others closely involved with the installation of piping systems. This is where needs are discovered, and where products and services are genuinely tested. Pipe hanger products included in this catalog are intended for installation and service only as described herein. TOLCO™ is proud to present a complete and versatile line of pipe hangers and related products. The TOLCO line has been methodically developed to effectively address support problems in the commercial and industrial piping fields. A thorough knowledge of our customers’ needs and problems was no less important than the development of our manufacturing skills in the emergency of TOLCO as a leader in the pipe hanger industry. Our people are equipped to respond quickly to your product and service needs on both standard items and specialized metal fabrication. We are aware that these products have been used (often without incident) for purposes and in ways other than those for which they were designed and manufactured. Examples of which are: use of products as erection tools; use of beam clamps on a beam not specified for them; use of concrete inserts as an anchor for pulling pipe to proper elevation; suspension of one clevis hanger under another resulting in cumulative load greater than specified capability. In such cases of misapplication or improper use, we cannot be held responsible for injuries or property damage. TOLCO pipe hanger products are carefully designed and manufactured to industry standards. Care should be exercised by installers and end users to install, use and maintain these products properly to avoid any possible on-the-job accidents. Custom Fabrication Designs We have expanded our manufacturing capacity in response to the growing demand for customized metal fabrication and special hangers. When some detail of construction or piping arrangement makes it necessary to deviate from standard types of hangers, TOLCO is equipped to furnish hangers and supports of any required type. These products combine proven designs and standards with new innovations that enhance their utility. Product design and specifications are subject to change without notice. Approvals and Specifications TOLCO, as a member of the American Pipe Fittings Association, is cooperating with engineers and architects in the preparation of specifications covering hanger requirements and the interpretation of applicable piping safety codes. All TOLCO products are carefully manufactured to meed the highest standards in the industry. All products, as a minimum conform to Manufacturers Standardization Society MSS-SP-58, and to the allowable stresses specified in the ANSI B31.1 code for pressure piping. Finishes Most hangers are available in: stainless steel, electro-galvanized or hot-dipped galvanized. Other special finishes are available upon request. Items ordered hot-dip galvanized may be supplied with electro-galvanized threaded components unless otherwise specified. If you require a finish not listed in the product data of a specific hanger, please consult our factory. Index Figure numbers in this catalog are in numerical order. Terms and Conditions of Sale For conditions and terms of sale, please consult our current price guide. Many TOLCO Products are also listed, approved or conform to: Underwriter’s Laboratories UL-203 Factory Mutual Engineering National Fire Protection Association NFPA-13, NFPA-13R, NFPA-13D and NFPA-24 Federal Specification WW-H-171EE Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com www.tolco.com Revision 4/26/2005 Index — Pipe Hangers and Straps Fig. 1 Fig. 1F Standard Clevis Hanger Standard Clevis Hanger MSS-SP-69, Type 1 with Felt Lining WW-H-171E, Type 1 Page 7 Page 5 Fig. 1PVC PVC Coated Clevis Hanger MSS-SP-69, Type 1 WW-H-171E, Type 1 Page 7 Fig. 2FWON Fig. 2F Fig. 2WON Adjustable Band Hanger Adjustable Band Hanger Adjustable Band Hanger w/o Swivel Nut with Felt Lining w/o Swivel Nut with Felt Lining MSS-SP-69, Type 10 MSS-SP-69, Type 7 MSS-SP-69, Type 10 WW-H-171E, Type 10 WW-H-171E, Type 7 WW-H-171E, Type 10 Page 9 Page 10 Page 10 Fig. 200WON Trimline Band Hanger w/o Swivel Nut MSS-SP-69, Type 7 WW-H-171E, Type 7 Page 42 Fig. 1CBS Cross Bolt Spacer Page 6 Fig. 2 Adjustable Band Hanger MSS-SP-69, Type 10 WW-H-171E, Type 10 Page 8 Fig. 2NFPA Trimline Band Hanger with Reducer Rod Size MSS-SP-69, Type 10 WW-H-171E, Type 10 Page 8 Fig. 24 Hanger for CPVC Plastic Pipe, Double Fastener Strap Type Side Mount Page 20 Fig. 200 Trimline Band Hanger MSS-SP-69, Type 10 WW-H-171E, Type 10 Page 40 Fig. 3 J-Hanger for Pipe or Conduit MSS-SP-69, Type 5 Page 11 Fig. 23 Hanger for CPVC Plastic Pipe, Double Fastener Strap Type Page 19 Fig. 22 Hanger for CPVC Plastic Pipe Single Fastener Type Page 17 Fig. 22C Combination Hanger Restrainer Application for CPVC Plastic Pipe Page 18 Fig. 120RWA (B) Retrofit Wrap Around U-Hanger Clamp MSS-SP-69, Type 4 WW-H-171E, Type 4 Page 38 Fig. 120RWA (A) Retrofit Wrap Around U-Hanger Clamp Page 38 Fig. 28 Fig. 26 Nail Plate Page 22 Fig. 3PVC J-Hanger with PVC Coating MSS-SP-69, Type 5 Page 11 Fig. 3F J-Hanger with Felt Lining MSS-SP-69, Type 5 Page 11 Standoff Hanger and Restrainer for CPVC Plastic Pipe Page 23 Fig. 120 U-Hanger Page 37 Fig. 324 Pipe Roller Hanger MSS-SP-69, Type 43 WW-H-171E, Type 44 Page 43 NOTE: For more information on TOLCO products, please see TOLCO™ Pipe Hangers and Support Systems Catalog. 2 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 4/26/2005 Index — Pipe Clamps Fig. 4B Seismic Pipe Clamp Page 14 Fig. 4 Standard Pipe Clamp MSS-SP-69, Type 4 WW-H-171E, Type 4 Page 12 Fig. 4A Pipe Clamp for Sway Bracing Page 13 Fig. 4F Standard Pipe Clamp with Felt Lining MSS-SP-69, Type 4 WW-H-171E, Type 4 Page 12 Fig. 4PVC PVC Coated Pipe Clamp Page 12 Fig. 6 Riser Clamp MSS-SP-69, Type 8 WW-H-171E, Type 8 Page 16 Fig. 6F Riser Clamp with Felt Lining MSS-SP-69, Type 8 Ww-H-171E, Type 8 Page 16 Fig. 6PVC PVC Coated Riser Clamp MSS-SP-69, Type 8 WW-H-171E, Type 8 Page 16 Beam Clamps and Accessories Fig. 61T Threaded Top Hook Page 27 Fig. 65 Steel Reversible "C" Type Beam Clamp with Lock Nut 3/4" Opening MSS-SP-69, Type 19 & 23 WW-H-171E, Type 23 Page 28 Fig. 66 Steel Reversible "C" Type Beam Clamp with Lock Nut 11/4" Opening MSS-SP-69, Type 19 & 23 WW-H-171E, Type 23 Page 28 Fig. 69 Beam Clamp Retaining Strap Page 31 Fig. 69R Retrofit Capable Beam Clamp Retaining Strap Page 32 Fig. 130 Beam Clamp with Bolt and Nut Page 39 Upper Attachments Fig. 42 Angle Bracket Page 24 Fig. 50 Side Beam Bracket Page 24 Fig. 51 Side Beam Bracket for NFPA Pipe Sizing Page 25 Fig. 58 Threaded Side Beam Bracket Page 26 Fig. 78 All Steel Ceiling Plate Page33 NOTE: For more information on TOLCO products, please see TOLCO™ Pipe Hangers and Support Systems Catalog. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 3 www.tolco.com Revision 5/24/2001 Index — Concrete Inserts Fig. 109A Concrete Deck Insert Page 35 Fig. 109F Concrete Insert Page 36 Threaded Products & Accessories Fig. 98 Rod Stiffener Page 34 Seismic Brace Attachments Fig. 4L Longitudinal “In-Line” Sway Brace Attachment Page 15 Fig. 907 4-Way Longitudinal Sway Brace Attachment Page 48 Fig. 981 Retrofit Universal Sway Brace Attachment Page 53 Fig. 25 Surge Restrainer Page 21 Fig. 800 Adjustable Sway Brace Attachment to Steel Page 44 Fig. 909 No-Thread Swivel Sway Brace Attachment Page 49 Fig. 990 Cable Sway Brace Attachment Page 54 Fig. 910 Swivel Sway Brace Fitting Page 50 Fig. 991 Cable Sway Brace Attachment Page 55 Fig. 825 Bar Joist Sway Brace Attachment Page 45 Fig. 825A Bar Joist Sway Brace Attachment Page 46 Fig. 975 Straight Sway Brace Fitting Page 51 Fig. 906 Sway Brace Multi-Fastener Adapter Page 47 Fig. 980 Universal Swivel Sway Brace Attachment Page 52 Fig. 1000 Fig. 1001 "Fast Clamp" Sway Brace Attachment Sway Brace Attachment Page 57 Page 56 Fig. 2002 Sway Brace Attachment Page 58 NOTE: For more information on TOLCO products, please see TOLCO™ Pipe Hangers and Support Systems Catalog. 4 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Component of State of California OSHPD Approved Seismic Restraints System Fig. 1 - Standard Clevis Hanger Size Range — Size 1/2" thru 36" pipe. Material — Carbon Steel Function — Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Note — When an oversized clevis is used, a pipe spacer should be placed over the cross bolt to assure that the lower U-strap will not move in on the bolt. When attaching seismic bracing to clevis hangers, a Fig. 1 CBS (cross bolt spacer) must be installed. See TOLCO™ Seismic Restraint Approval Guidelines. APPROVALS — Underwriters’ Laboratories Listed in the USA (UL), Canada (cUL) 3/4" thru 8". FM Approved 3/4" - 11/2", 6" - 8".Conforms to Federal Specification WW-H-171E, Type 1, and Manufacturers Standardization Society SP-58, Type 1. Also available to accommodate rod schedule per National Fire Protection Association (NFPA) Pamphlet 13. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Maximum Temperature — 650°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel. Dimensions • Weights Pipe Size Rod Size A STD NFPA B C D Max. Rec. Load Lbs. Approx. Wt./100 1/2 3/4 1 3/8 3/8 3/8 3/8 3/8 3/8 21⁄16 27⁄8 31⁄4 13⁄16 17⁄8 21⁄16 1 1 1 610 610 610 36 38 42 11⁄4 11⁄2 2 3/8 3/8 3/8 3/8 3/8 3/8 39⁄16 37⁄8 47⁄16 21⁄4 23⁄8 23⁄4 1 1 1 610 610 610 46 49 55 21⁄2 3 31⁄2 1/2 1/2 1/2 3/8 3/8 3/8 55⁄16 515⁄16 67⁄16 31⁄4 31⁄2 33⁄4 1 11⁄4 11⁄4 1130 1130 1130 124 140 152 4 5 6 8 10 12 5/8 5/8 3/4 3/4 7/8 7/8 3/8 1/2 1/2 1/2 5/8 5/8 73⁄8 815⁄16 913⁄16 129⁄16 161⁄4 191⁄4 41⁄4 51⁄4 51⁄2 71⁄8 95⁄8 115⁄8 11⁄2 11⁄2 11⁄2 2 31⁄4 31⁄2 1430 1430 1940 2000 3600 3800 190 235 317 428 918 1143 14 16 18 1 1 1 — — — 2013⁄16 2115⁄16 247⁄16 125⁄16 127⁄16 1315⁄16 313⁄16 35⁄8 37⁄8 4200 4600 4800 1543 1925 2243 20 *24 *30 *36 11⁄4 11⁄4 11⁄4 11⁄2 — — — — 265⁄16 313⁄8 387⁄8 48 147⁄16 171⁄2 217⁄8 273⁄4 4 41⁄4 5 53⁄4 4800 4800 6000 9500 4161 4835 6940 18103 *Furnished with pipe spacer to support maximum load rating OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 5 www.tolco.com Revision 5/24/2001 Fig. 1CBS - Clevis Bolt Spacer Component of State of California OSHPD Approved Seismic Restraints System Size Range — Size 1" thru 20" clevis hanger Material — Carbon Steel Function — Used as a spacer at a seismic brace location to keep clevis hanger from collapsing during seismic event. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Note — Fig. 1CBS fits easily over the cross bolt and attaches by pinching tabs down. Finish — Mil Galvanized Note — Available in HDG finish or Stainless Steel materials. 6 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/24/2001 Fig. 1F — Felt Lined Standard Clevis Hanger Fig. 1PVC — PVC Coated Standard Clevis Hanger Size Range — Size 1/2" thru 8" pipe. Material — Carbon Steel Insulation Material — 3/16" felt Function — The Fig. 1F is designed for the suspension of copper tube so as to prevent electrolysis between tube and hanger. The Fig. 1PVC is designed for steel or other pipe types of same O.D. Both Fig. 1F and Fig. 1PVC act to reduce noise and vibration in pipe or tube system. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Maximum Temperature — 650°F Finish — Plain Note —When Fig. 1F is used for steel or other pipe types, consult factory for proper size hanger. Available in Electro-Galvanized and HDG finish or Stainless Steel. Order By — Figure number, nominal tube size and finish Fig. 1F Fig. 1PVC Dimensions • Weights Pipe Size Rod Size A STD NFPA B C D Max. Rec. Load Lbs. Approx. Wt./100 1/2 3/4 1 3/8 3/8 3/8 3/8 3/8 3/8 27⁄8 31⁄16 33⁄8 1 111⁄16 17⁄8 1 1 1 610 610 610 36 38 43 11⁄4 11⁄2 2 3/8 3/8 3/8 3/8 3/8 3/8 33⁄4 41⁄16 41⁄2 21⁄16 23⁄16 29⁄16 1 1 1 610 610 610 47 50 56 21⁄2 3 31⁄2 1/2 1/2 1/2 3/8 3/8 3/8 51⁄2 61⁄8 63⁄4 31⁄16 35⁄16 39⁄16 1 11⁄4 11⁄4 1130 1130 1130 125 141 153 4 5 6 8 5/8 5/8 3/4 3/4 3/8 1/2 1/2 1/2 75⁄8 87⁄8 10 123⁄4 41⁄16 51⁄16 55⁄16 615⁄16 11⁄2 11⁄2 11⁄2 2 1430 1430 1940 2000 191 236 318 429 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 7 www.tolco.com Revision 3/31/2003 Fig. 2 — Adjustable Band Hanger Fig. 2NFPA — Adjustable Band Hanger with Reduced Rod Size Range — Size 21/2" thru 4" pipe. Material — Carbon Steel, Pre-Galvanized Function — Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Finish — Pre-Galvanized Note — Available in Stainless Steel materials. Order By — Figure number, pipe size and material Component of State of California OSHPD Approved Seismic Restraints System Dimensions • Weights * ** 8 Pipe Size Rod Size A B C Max. Rec. Load Lbs. 21⁄2 3 31⁄2 4 5 6 1/2* 1/2* 1/2* 5/8* 5/8** 3/4** 53⁄4 6 73⁄8 73⁄8 9 93⁄8 41⁄4 41⁄8 51⁄4 5 61⁄8 61⁄2 15⁄8 11⁄4 21⁄8 15⁄8 21⁄4 17⁄8 600 600 600 1000 1250 1250 Approx Wt./100 Fig. 2 Fig. 2NFPA 41 45 52 59 97 139 3/8" nut is used when NFPA rod sizing is requested. 1/2" nut is used when NFPA rod sizing is requested. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 40 43 50 56 95 105 www.tolco.com Revision 3/31/2003 Fig. 2F - Adjustable Band Hanger with Felt Lining Size Range — 1/2" thru 6" copper tubing Material — Carbon Steel, Pre-Galvanized Function — Recommended for the suspension of copper tube so as to prevent electrolysis. The felt lining also acts to reduce noise in copper or other pipe types. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Conforms to Federal Specification WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish — Pre-Galvanized Note — When used for steel or other pipe types, consult factory for proper size. Available in Stainless Steel materials. Order By — Figure number and copper tube size Dimensions • Weights Copper Tube Size Rod Size A B C Max. Rec. Load Lbs. Approx. Wt./100 1/2 3/4 1 3/8 3/8 3/8 31/8 31/8 33/8 25/8 21⁄2 25/8 13/8 11/8 11/8 400 400 400 12 12 13 11⁄4 11⁄2 2 3/8 3/8 3/8 33/4 37/8 41⁄4 27/8 27/8 3 11⁄4 11/8 1 400 400 400 14 15 16 21⁄2* 3* 31⁄2* 1/2 1/2 1/2 53/4 6 73/8 41/8 4 51⁄4 13/4 11⁄2 13/8 600 600 600 41 46 53 4* 5** 6** 5/8 5/8 3/4 73/8 9 93/8 5 61/8 61⁄2 17/8 21⁄2 21⁄4 1000 1250 1250 60 98 140 * 3/8" nut is used when requested. ** 1/2" nut is used when requested. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 9 www.tolco.com Revision 5/24/2001 Fig. 2WON - Adjustable Band Hanger w/o Swivel Nut Fig. 2FWON - Felt Lined Band Hanger w/o Swivel Nut Size Range — (Fig. 2WON) Size 1/2" thru 8" pipe. (Fig. 2F WON) 1/2" thru 8" copper tube Material — Pre-Galvanized Steel Function — Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Conforms to Federal Specification WW-H-171E, Type 7, and Manufacturers Standardization Society SP-69, Type 7, 3/4" thru 6". Finish — Pre-Galvanized Note — Available in Stainless Steel materials. Order By — Figure number and pipe size Fig. 2WON Fig. 2F WON Dimensions • Weights Pipe Size Rod Size A B C D Max. Rec. Load Lbs. Approx. Wt./100 1/2 3/4 1 3/8 3/8 3/8 25⁄8 25⁄8 27⁄8 21⁄8 2 21⁄8 11⁄4 1 1 400 400 400 14 14 16 11⁄4 11⁄2 2 3/8 3/8 3/8 33⁄8 31⁄2 33⁄4 21⁄2 21⁄2 21⁄2 11⁄4 1 7/8 400 400 400 17 18 20 21⁄2 3 31⁄2 1/2* 1/2* 1/2* 5 51⁄2 63⁄4 31⁄2 35⁄8 45⁄8 11⁄2 11⁄4 2 600 600 600 27 40 48 4 5 6 8 5/8* 5/8** 3/4** 3/4** 63⁄4 81⁄2 91⁄4 121⁄4 43⁄8 55⁄8 57⁄8 77⁄8 11⁄2 21⁄8 15⁄8 25⁄8 1000 1250 1250 1250 53 91 99 120 * 3/8" nut is used when NFPA rod sizing is requested. ** 1/2" nut is used when NFPA rod sizing is requested. 10 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Component of State of Fig. 3 - J-Hanger for Pipe or Conduit California OSHPD Approved Seismic Restraints System Fig. 3F - Felt Lined J-Hanger for Copper Tubing Fig. 3PVC - PVC Coated J-Hanger for Pipe or Conduit Size Range — 1/2" thru 12" pipe Material — Carbon Steel Function — Recommended for the suspension of non-insulated pipe, or insulated pipe with Fig. 220 shield. Side hole allows for wall mounting. Fig. 3F and Fig. 3PVC are designed to reduce noise and vibration and/or prevent electrolysis between pipe and hanger. Approvals — Conforms to Manufacturers Standardization Society SP-69, Type 5. Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Electro-Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number, pipe size and finish Fig. 3 Fig. 3PVC Fig. 3F Dimensions • Weights Copper Tube Size Rod Size A B C D E F Max. Rec. Load Lbs. Approx. Wt./100 1/2 3/4 1 3/8 3/8 3/8 25⁄8 27⁄8 215⁄16 13⁄4 17⁄8 115⁄16 7/16 7/16 7/16 11⁄2 111⁄16 113⁄16 115⁄166 21⁄8 25⁄16 400 400 400 18 21 22 11⁄4 11⁄2 2 3/8 3/8 3/8 31⁄4 39⁄16 311⁄16 2 23⁄16 21⁄8 7/16 7/16 7/16 21⁄16 27⁄16 29⁄16 25⁄8 27⁄8 31⁄16 400 400 400 25 27 29 21⁄2 3 31⁄2 1/2 1/2 1/2 47⁄16 413⁄16 51⁄8 27⁄16 29⁄16 25⁄8 9/16 9/16 9/16 33⁄16 31⁄2 33⁄4 35⁄8 41⁄16 43⁄8 500 500 500 64 72 84 4 5 6 5/8 5/8 3/4 61⁄8 63⁄4 73⁄4 33⁄16 31⁄4 39⁄16 9/16 9/16 9/16 45⁄8 51⁄16 513⁄16 53⁄16 53⁄4 65⁄8 550 550 600 138 162 249 8 10 7/8 7/8 93⁄16 103⁄4 315⁄16 37⁄8 9/16 9/16 615⁄16 75⁄8 8 91⁄8 760 760 291 315 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 11 www.tolco.com Revision 5/31/2005 Component of State of California OSHPD Approved Seismic Restraints System Fig. 4 - Standard Pipe Clamp Fig. 4F - Standard Pipe Clamp Felt Lined Fig. 4PVC - Standard Pipe Clamp PVC Coated Size Range — (Fig. 4) Size 1/2" thru 30" pipe. Size Range — (Fig. 4F) Size 1/2" thru 21/2" copper tubing Material — Carbon Steel Function — Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shields. (Use Fig. 330 Weldless Eye Nut, Fig. 102 Eye Rod or Fig. 101 Welded Eye Rod.) Also recommended for attachment of sway bracing up to 31/2" pipe size, for larger pipe sizes use Fig. 4A. Fig. 4F and Fig. 4PVC are designed to reduce noise and vibration and/or prevent electrolysis. Approvals — Underwriters’ Laboratories Listed in the USA (UL), Canada (cUL) 3/4" - 8", and approved by Factory Mutual Engineering, 3/4" - 8". Federal Specification WW-H-171E, Type 4, 11/2" thru 24" and Manufacturers Standardization Society SP-69, Type 4. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note — When the Fig. 4 is used as a sway brace, to ensure performance, the UL Listing requires that it must be used with other TOLCO™ brace products. Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size and finish. Fig. 4F Order Note — When ordering Fig. 4F allow for 3/16" felt on each half of clamp. Fig. 4 Fig. 4PVC Dimensions • Weights Max. Design Load Lbs. For Service Temp. 650° 750°F Pipe Size A B C D Bolt Size 1/2 3/4 1 37⁄16 39⁄16 39⁄16 1/4 1/4 1/4 11⁄8 11⁄4 11⁄4 11⁄8 11⁄4 15⁄16 5/16 5/16 5/16 500 500 500 445 445 445 29 31 35 11⁄4 11⁄2 2* 43⁄16 49⁄16 59⁄16 1/2 5/16 1/2 13⁄8 15⁄8 2 111⁄16 17⁄8 21⁄4 5/16 5/16 3/8 500 800 1040 445 715 930 40 42 93 21⁄2* 3* 31⁄2* 67⁄16 7 711⁄16 9/16 5/8 3/8 21⁄2 23⁄4 31⁄8 23⁄4 31⁄16 33⁄8 1/2 1/2 1/2 1040 1040 1040 930 930 930 126 141 154 4 5 6 81⁄2 93⁄4 115⁄8 5/8 3/4 3/4 35⁄16 37⁄8 47⁄8 311⁄16 43⁄8 51⁄8 5/8 5/8 3/4 1040 1040 1615 930 930 1440 229 261 537 8 10 12 135⁄16 161⁄2 181⁄2 1 1 1 55⁄8 71⁄4 81⁄4 6 71⁄4 81⁄4 3/4 7/8 7/8 1615 2490 2490 1440 2220 2220 625 1378 1574 14 16 18 20 23 257⁄8 11⁄8 11⁄8 11⁄4 9 101⁄4 111⁄2 9 101⁄4 111⁄2 7/8 7/8 1 2490 2490 3060 2220 2220 2730 2103 2314 3276 Approx. Wt./100 121⁄2 121⁄2 11⁄8 3060 2730 3863 20 28 13⁄8 24 331⁄2 15⁄8 151⁄4 151⁄4 11⁄4 3060 2730 5222 30 417⁄8 2 19 19 13⁄4 3500 3360 10511 *Meets UL 203A requirements for attachment of sway bracing. Horizontal design load for 1/2"-2" - 380#, 21⁄2" - 395#, 3" - 435#, 31⁄2" - 540# 12 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/5/2006 Component of State of California OSHPD Approved Seismic Restraints System Fig. 4A - Pipe Clamp for Sway Bracing Size Range — 4" thru 8" pipe. For sizes smaller than 4" use TOLCO™ Fig. 4. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) 4" thru 8". Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Installation Instructions — The Fig. 4A is the "braced pipe" attachment component of a longitudinal, lateral or riser brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install — Place the Fig. 4A over the pipe to be braced. Attach TOLCO transitional fitting, either Fig. 980, 910 or 909, to the clamp ears. Tighten bolts and nuts; torque requirement is a minimum of 50 ft. lbs. Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size and finish Fig. 4A - Longitudinal Brace Dimensions • Weights Pipe Sizes A B C D Bolt Size Max. Horizontal Design Load Approx. Wt./100 4 5 6 8 81⁄2 93⁄4 111⁄2 131⁄4 9/16 9/16 5/8 3/4 33⁄8 37⁄8 5 611⁄16 311⁄16 43⁄8 51⁄8 61⁄8 1/2 1/2 1/2 1/2 2015 2015 2015 2015 221 253 513 601 TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 13 www.tolco.com Revision 5/5/2006 Fig. 4B - Pipe Clamp for Sway Bracing Component of State of California OSHPD Approved Seismic Restraints System Size Range — 3/4" thru 8" pipe. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. Features — This product's design incorporates concentric loading of the "brace pipe", connection components and fasteners which is critical to the performance of seismic bracing assemblies. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restrains Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size and finish. Installation Instructions — The Fig. 4B is the "braced pipe" attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be Shown with two TOLCO™ followed. Fig. 980’s and Schedule 40 brace pipe. To Install — Place the Fig. 4B over the pipe to be braced. Attach other TOLCO transitional fitting, Fig. 909, 910 or 980. Tighten bolts and nuts. Transitional fitting attachment can pivot for adjustment to proper brace angle. Fig. 4B - Hanger/Longitudinal Brace Dimensions • Weights Pipe Sizes Rod Size A B C D Bolt Size Max. Design Load Lbs. Approx. Wt./100 3/4 1 11⁄4 3/8 3/8 3/8 1 1 1 27⁄8 31⁄4 39⁄16 25⁄8 215⁄16 31⁄4 5/16 5/16 5/16 330 330 330 56 60 74 11⁄2 2 21⁄2 3/8 3/8 1/2 1 11⁄2 13⁄4 313⁄16 51⁄8 55⁄8 37⁄16 45⁄8 53⁄8 5/16 5/16 3/8 330 440 440 79 156 176 3 31⁄2 4 1/2 1/2 5/8 17⁄8 2 2 63⁄4 71⁄4 85⁄8 61⁄8 63⁄4 71⁄4 3/8 3/8 1/2 660 660 800 198 219 288 5 6 8 5/8 3/4 7/8 2 21⁄8 21⁄8 97⁄8 1015⁄16 137⁄16 85⁄16 91⁄2 111⁄2 5/8 5/8 3/4 980 980 1200 390 448 691 TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. 14 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/5/2006 Fig. 4L Longitudinal “In-Line” Sway Brace Attachment Size Range — 2½" through 8" IPS. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. Approvals — Underwriter's Laboratories Listed in the USA (UL) and Canada (cUL) 2½" through 8". Installation Instructions — The Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install — Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in electro-galvanized and HDG finish. Order By — Figure number, pipe size and finish. Dimensions • Weights Sizes A C D Bolt Size Max. Rec. Load Lbs. Approx. Wt./100 21⁄2 3 4 5 6 8 67⁄16 7 81⁄2 93⁄4 111⁄2 131⁄4 21⁄2 23⁄4 33⁄8 37⁄8 5 611⁄16 23⁄4 31⁄16 311⁄16 43⁄8 51⁄8 61⁄8 1/2 1/2 1/2 1/2 1/2 1/2 2015 2015 2015 2015 2015 2015 253 268 348 380 640 728 Longitudinal Brace 4-Way Riser Brace (Plan view) TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 15 www.tolco.com Revision 5/24/2001 Fig. 6 - Riser Clamp Fig. 6F - Felt Lined Riser Clamp Fig. 6PVC - PVC Coated Riser Clamp Size Range — (Fig. 6) 1/2" thru 20" pipe (Fig. 6F) 1/2" thru 21/2" copper tubing (Fig. 6PVC) 1/2" thru 6" pipe Material — Carbon Steel Insulation Material — (Fig. 6F) 3/16" felt. Function — Used for supporting vertical piping. Approvals — Underwriters’ Laboratories Listed in the USA (UL), Canada (cUL) 1/2" - 8". Factory Mutual Engineering Approved, 3/4" thru 8". Conforms to Federal Specification WW-H-171E, Type 8, 3/4" thru 20" and Manufacturers Standardization Society SP-69, Type 8. Maximum Temperature — 650°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — (Fig. 6 and Fig. 6PVC) pipe size and finish. (Fig. 6F) copper tube size and finish. (Fig. 6F is available for Iron Pipe Size, consult factory. Fig. 6 Fig. 6PVC Fig. 6F Dimensions • Weights 16 Pipe Size A B C Bolt Size Max. Rec. Load Lbs. Approx. Wt./100 1/2 3/4 1 91⁄4 91⁄4 99⁄16 1/2 1/2 1/2 11⁄8 11⁄8 11⁄4 3/8 3/8 3/8 255 255 255 144 144 147 11⁄4 11⁄2 2 911⁄16 103⁄8 103⁄4 1/2 1/2 1/2 13⁄8 11⁄2 2 3/8 3/8 3/8 255 255 255 150 153 165 21⁄2 3 31⁄2 11 12 13 5/8 5/8 5/8 21⁄4 3 31⁄4 3/8 3/8 1/2 390 530 670 228 246 264 4 5 6 131⁄2 141⁄2 151⁄8 3/4 3/4 7/8 33⁄8 43⁄8 47⁄8 1/2 1/2 1/2 810 1160 1570 347 385 564 8 10 12 14 16 18 20 181⁄2 201⁄4 223⁄4 24 26 28 30 1 1 1 11⁄8 11⁄8 11⁄4 13⁄8 53⁄4 71⁄4 81⁄4 9 101⁄4 111⁄2 121⁄2 5/8 5/8 5/8 5/8 3/4 3/4 3/4 2500 2500 2700 2700 2900 2900 2900 1017 1138 1759 1922 3245 3372 3499 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 3/31/2003 Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Type Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger to support only CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCO™ Fig. 23, Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design* protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been know to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Note — Fastener into light gauge metal may be ordered separately. Minimum acceptable: #10 x 1" Hardened Self Threading Screw with 5/16" hex washer head. Order By — Figure number and CPVC pipe size. * Patent Pending Dimensions • Weights CPVC Pipe Size A B C Max. Hanger Spacing (Ft.) Fastener Hex Head Size Approx. Wt./100 3/4 1 11⁄4 11⁄2 2 27⁄16 211⁄16 31⁄16 35⁄16 33⁄4 15⁄16 17⁄16 15⁄8 13⁄4 21⁄8 13⁄16 13⁄16 13⁄16 13⁄16 13⁄16 51⁄2 6 61⁄2 7 8 5/16 5/16 5/16 5/16 5/16 9 9 11 12 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 17 www.tolco.com Revision 3/31/2003 Fig. 22C - Combination Hanger & Restrainer Application Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Designed to support a CPVC pipe away from the corner of a beam. This position allows for easy installation of drops or risers without adding additional wood blocks. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) for use as a combination hanger and restrainer. Finish — Pre-Galvanized Note — Approved UL Listed fastener into wood is furnished with the product. A fastener into light gauge metal may be ordered separately. Minimum acceptable #10 x 1" hardened self threading screw with 5/16" hex washer head. Order By — Fig. 22C application is composed of two standard Fig. 22 models — order two singles for each hanger and restrainer application required. 18 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/24/2001 Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Order By — Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights CPVC Pipe Size A B C Max. Hanger Spacing (Ft.) Fastener Hex Head Size Approx. Wt./100 3/4 1 11⁄4 31⁄8 33⁄8 43⁄16 19⁄16 111⁄16 23⁄32 13⁄16 13⁄16 13⁄16 51⁄2 6 61⁄2 5/16 5/16 5/16 9 9 11 11⁄2 2 47⁄16 47⁄8 27⁄32 27⁄16 13⁄16 13⁄16 7 8 5/16 5/16 12 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 19 www.tolco.com Revision 5/24/2001 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount Size Range — 3/4" thru 2" CPVC pipe Material — Carbon Steel, Pre-Galvanized Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish — Pre-Galvanized Order By — Figure number and pipe size * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights CPVC Pipe Size A B C Max. Hanger Spacing (Ft.) Fastener Hex Head Size Approx. Wt./100 3/4 1 11⁄4 25⁄16 25⁄8 3 15⁄32 15⁄16 11⁄2 13⁄16 13⁄16 13⁄16 51⁄2 6 61⁄2 5/16 5/16 5/16 9 9 11 11⁄2 2 31⁄4 311⁄16 15⁄8 127⁄32 13⁄16 13⁄16 7 8 5/16 5/16 12 15 20 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 3/24/2003 Fig. 25 - Surge Restrainer Size Range — One size fits 3/4" thru 2" pipe. Material — Steel Function — Designed to be used in conjunction with TOLCO™ Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the bank hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association (NFPA 13, 1999 Edition), 6-2.3.3, 62.3.4 and A-6i-2.3.3 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters’ Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre-Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 21 www.tolco.com Revision 6/12/2006 Fig. 26 - Nail Plate Sizes - Small – 11/2" x 23/4" Large – 3" x 23/4" Material – Carbon Steel Finish – Plain Function – To prevent damage to plastic pipe or conduit from installation of fasteners after pipe has been installed, such as drywall screws, nails etc. The Small size is designed to be installed on the side of a 2x4, while the Large size is designed for either a 4x4 or two stacked 2 x4’s such as at the base and at the top of framing walls. Installation – Designed to be installed into wood structural member adjacent to the pipe. No fasteners required. Order By - Figure Number and size (small or large) Small Large 22 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com www.tolco. Revision 5/24/2001 Fig. 28 - "Stand-Off" Hanger & Restrainer for CPVC Plastic Pipe Size Range — 3/4" through 2" Material — Carbon Steel, Pre-Galvanized Function — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand-Off" design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attached easily to wood structure with two hex head self-threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" extension socket eliminating impact tool damage to pipe. • U.L. Listed as a hanger and a restrainer for fire sprinkler piping. Approvals — Underwriters' Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by — Figure number and pipe size. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Dimensions • Weights 23 Pipe Size A 3/4 1 11⁄4 11⁄2 2 31⁄32 35⁄16 35⁄8 4 41⁄2 B C Approx. Wt. 2 23⁄16 23⁄8 21⁄2 211⁄16 31⁄2 31⁄2 31⁄2 31⁄2 35⁄8 .180 .210 .225 .310 .340 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 23 ™ www.tolco.com ® Revision 5/24/2001 a brand of Fig. 42 - Angle Bracket Material — Carbon Steel Function — Recommended for supporting pipe at various distances from wall or column. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, size and finish Dimensions • Weights Pipe Size A B Hole Size Max. Rec. Load Lbs. 1 2 3 4 3 4 3 4 2 3 2 3 7/16 7/16 9/16 9/16 180 180 390 390 Approx. Wt./100 46 65 85 115 Fig. 50 - Side Beam Bracket Size Range — 3/8" thru 7/8" rod Material — Carbon Steel Function — Recommended for attaching hanger rod to side of beams or walls. Approvals — 3/8", Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod size and finish Dimensions • Weights Pipe Size A B C Hole Size Max. Rec. Load Lbs. 3/8 1/2 5/8 2 2 2 3/4 3/4 3/4 2 2 2 7/16 9/16 11/16 700 700 700 35 35 32 3/4 7/8 21⁄2 21⁄2 3/4 3/4 21⁄2 21⁄2 13/16 15/16 1250 1250 110 100 24 Approx. Wt./100 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 24 ™ www.tolco.com ® Revision 5/24/2001 a brand of Fig. 51 - Side Beam Bracket for NFPA Rod and Fastener Sizing Size Range — 3/8" and 1/2" rod, 1/2" thru 8" pipe Material — Carbon Steel Function — Recommended for attaching hanger rod to side of beams or walls. Designed to accommodate current rod schedule and fastener requirements per National Fire Protection Association (NFPA) Pamphlet 13. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod size and finish Dimensions • Weights Pipe Rod Size Size 1/2 - 2 21⁄2 - 4 5-6 8 25 3/8 3/8 1/2 1/2 Hole Size A B C H-1 H-2 Max. Rec. Load Lbs. 2 2 21⁄2 21⁄2 3/4 3/4 3/4 3/4 2 2 21⁄2 21⁄2 7/16 9/16 9/16 11/16 7/16 7/16 9/16 9/16 700 700 1250 1250 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Approx. Wt./100 35 34 71 70 25 www.tolco.com Revision 5/24/2001 Fig. 58 - Threaded Side Beam Bracket Size Range — 3/8" rod, pipe sizes 1/2" thru 4" Material — Carbon Steel Function — Practical and economical bracket used to support piping from wood, concrete or steel beams. Features — Unique design allows rod to be easily threaded into bracket. Offset design permits unlimited rod adjustment. Center mounting hole will accept 3/8" and 1/2" fastener bolts. Per NFPA 13: 1/2" thru 2" pipe requires 3/8" fastener, 21/2" thru 4" pipe requires 1/2" fastener.* Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL), and Factory Mutual Engineering approved thru 4" pipe. *Note — Additionally UL has listed the Fig. 58 with fasteners as shown in table below. Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number and finish Dimensions • Weights Pipe Size Qty. 2 2 21⁄2 - 4 31⁄2 4 4 4 2 1 1 2 2 2 2 Fastener Type Material #16 x 2 Drive Screws Wood 3/8 Lag Bolt Wood 1/2 Lag Bolt Wood 1/4 x 11⁄2 Lag Bolt Wood 1/4 x 2 Lag Bolts* Wood 1/4 x 1 tek screws 14 gauge 1/4 x 1 tek screws 16 gauge * No pre-drilling required Dimensions • Weights Pipe Size Rod Size A B C Max. Rec. Load Lbs. 1/2 thru 4 3/8 23⁄4 11⁄2 11⁄8 300 26 Approx. Wt./100 14 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 26 www.tolco.com Revision 5/24/2001 Fig. 61T - Bar Joist Hanger Size Range — 3/8" thru 1/2" rod sizes Material — Carbon Steel Function — Designed to hook on top chord of metal bar joist. Hanger rod is threaded into product and secured with a washer and nut. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL) for up to 4" pipe with 3/8" rod, up to 6" pipe with 1/2" rod. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, rod size, and thickness of bar joist. Dimensions • Weights Pipe Size Rod Size Max. Rec. Load Lbs. Up to 4 6 3/8 1/2 300 600 27 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 27 www.tolco.com Revision 5/24/2001 Fig. 65 and Fig. 66 - Reversible C-Type Beam Clamps 3/4" and 11⁄4" Throat Openings Size Range — (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material — Carbon Steel with hardened cup point set screw and jam nut Function — Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Federal Specification WW-H-171E, Type 23 and Manufacturers Standardization Society SP-69, Type 19. Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish Fig. 65 Patent #4,570,885 Fig. 65 Dimensions • Weights Rod Size A B C D E F 3/8 1/2 5/8 13⁄16 11⁄2 11⁄2 3/4 3/4 3/4 1 1 1 7/16 9/16 9/16 1 11⁄4 11⁄4 Max. Rec. Approx. Load Lbs.* Wt./100 610 1130 1130 28 55 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size A B C D E F 3/8 1/2 5/8 13⁄16 11⁄2 11⁄2 11⁄4 11⁄4 11⁄4 1 1 1 7/16 9/16 9/16 1 11⁄4 11⁄4 Max. Rec. Approx. Load Lbs.* Wt./100 610 1130 1130 28 55 55 * Max. loads for clamp with set screw in up or down position. 28 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System www.tolco.com Revision 5/31/2005 Fig. 67SS - Stainless Steel Reversible C-Type Beam Clamps 3/4" and 11⁄4" Throat Openings Size Range — 3/8" and 1/2" rod sizes Material — All Stainless Steel (T-316 or T-304) Function — Recommended for hanging from steel beams where flange thickness does not exceed 3/4". Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Approvals — Underwriters’ Laboratories LIsted in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Manufacturers’ Standardization Society SP-69, Type 19. Meets or exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8" rod will support 1/2" through 4" pipe, 1/2" rod will support 1/2" through 8" pipe. Order By — Figure number and rod size Fig. 67SS Dimensions • Weights Pipe Size A B C D E F G 1/2 - 4 5, 6, 8 3/8 1/2 17⁄8 17⁄8 11⁄2 13⁄4 3/4 13/16 3/4 3/4 7/8 7/8 11⁄8 11⁄8 Stock Size Test Load Approx. Wt./100 5/16 x 1 3/8 x 11⁄2 1500 lbs. 4050 lbs. 47 84 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 29 www.tolco.com Revision 5/31/2005 Fig. 68SS - Stainless Steel Reversible C-Type Beam Clamps 3/4" and 11⁄4" Throat Openings Size Range — 3/8" and 1/2" rod sizes Material — All Stainless Steel (T-316 or T-304) Function — Recommended for hanging from steel beams where flange thickness does not exceed 11⁄4" (Fig. 68SS). Features — All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Approvals — Underwriters’ Laboratories LIsted in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Conforms to Manufacturers’ Standardization Society SP-69, Type 19. Meets or exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, 3/8" rod will support 1/2" through 4" pipe, 1/2" rod will support 1/2" through 8" pipe. Order By — Figure number and rod size Fig. 68SS Dimensions • Weights Pipe 30 Size A B C D E F Stock Size Test Load Approx. Wt./100 1/2 - 4 5, 6, 8 3/8 1/2 21⁄16 21⁄4 2 21⁄4 3/4 13/16 11⁄4 11⁄4 11⁄8 11⁄4 3/8 x 11⁄2 1/2 x 2 1500 lbs. 4050 lbs. 84 170 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/13/2005 Fig. 69 - Beam Clamp Retaining Strap Size Range — 3/8" thru 7/8" rod by 4" thru 16" length.* Function — To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Important Note — Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind such as a hex nut or the beveled locking slot on the TOLCO™ Fig. 69R will provide a more secure reliable installation. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Component of State of California OSHPD Approved Seismic Restraints System B Finish — Pre-Galvanized Order By — Figure number, type, length “B” and rod size being used with beam clamp Note — Minimum return on Strap: 1". Dimensions • Weights Type Rod Size A Hole Size B 1 3/8 1/2 5/8 3/4 3/8 - 7/8 7/16 9/16 11/16 13/16 Specify Specify Specify Specify Specify Specify 2 3 * Longer lengths are available, consult factory. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 31 www.tolco.com Revision 8/31/2001 Fig. 69R - Retrofit Capable Beam Clamp Retaining Strap Size Range — 3/8" and 1/2" rod; 4" thru 16" length.** Material — Pre-Galvanized Steel Function — To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (1999) 6-4.7.1. Features — Beveled locking slot* is precisely formed to align with the threaded section of a hanger rod or set screw and engage the unit securely. May be used as shown in section “A-A” or inverted. Allows easy installation for new construction or retrofit applications. Important Note — Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking mechanism of some kind, such as the beveled locking slot of the Fig. 69R or a hex nut tightened against other types of retaining straps will provide a more secure and reliable installation. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Pre-Galvanized Order By — Figure number, rod or set screw size and length Note — Minimum return on Strap: 1". * Patent #5,947,424 Dimensions • Weights Rod Size A 3/8" 1/2" 32 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Length Specify Specify www.tolco.com Revision 3/31/2003 Fig. 78 - All Steel Ceiling Plate Size Range — 3/8" rod Material — Carbon Steel Features — Attachment to wood beams, ceilings, metal decks or walls. Can also be welded to steel beams. Approvals — Underwriters’ Laboratories Listed in the USA (UL) and Canada (cUL). Factory Mutual Engineering approved. Additionally, (UL) has listed the Fig. 78 with fasteners as shown in the table below. Finish — Plain and Electro-Galvanized Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, rod size and finish A C B E D(2) Patent #5,702,077 UL Listed Fastener Table Pipe Size Qty Fastener Type 11⁄4 Material 1/2 - 2 21⁄2 - 4 1/2 - 2 2 2 2 #14 x A-point hex-washer-head sheet metal screw 1/4 x 11⁄2 wood screws* 1/4 x 1 tek screws 1/2 - 2 1/2 - 2 2 2 #14 x 11⁄4 A-point hex-washer-head sheet metal screw #14 x 2 A-point-hex-washer-head sheet metal screw Wood Wood Metal (18 gauge) Wood Wood thru 5/8" gyp board * No pre-drilling Dimensions • Weights Pipe Size A B C 1/2 - 2 5-6 3 21⁄8 11⁄8 D E 5/16 3/8 Consult factory for data Max. Rec. Load Lbs.* Approx. Wt./100 150 15 * Minimum safety factor of 5 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 33 ™ www.tolco.com www.tolco.com ® Revision 5/24/2001 a brand of Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved Seismic Restraints System Size Range — Secures 3/8" thru 7/8" hanger rod Material — Carbon Steel Function — Secures channel to hanger rod for vertical seismic bracing. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish — Electro Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number 34 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Component of State of California OSHPD Approved Seismic Restraints System Fig. 109A - Concrete Deck Insert Size Range — 3/8" thru 7/8" rod Material — Carbon Steel Function — For use in metal deck formed concrete to attach hanger rods. Allows for pre-positioning of hanger rods in poured concrete decks. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraints Systems Guidelines. Hangers certified by a registered professional engineer to conform to Section 6-1.1 of NFPA #13 (1999) and Section 9.1.1.2 of NFPA #13 (2002). Finish — Plate: Plain Steel. Rod: Electro-Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number, rod size and finish. Custom rod lengths are available. Consult factory. Spacing/Load Chart for 3000 PSI Light Weight Concrete over 20 GA Steel Deck Rod Size Max. Pipe Size Max. Hanger Spacing Max. Rec Loads 3/8 1/2 5/8 4" 15'-0" 8" 15'-0" Consult Factory Consult Factory 1144 1158 1430 3/4 7/8 Consult Factory Consult Factory Consult Factory Consult Factory 2000 2000 NOTES: 1. Mounting holes are standard. If the plate is not mechanically secured to the deck ribs, a jam nut is required to prevent the anchor bolt from laying over when concrete is poured. 2. Minimum spacing between inserts shall be not less than 41⁄2" for 3/8" and 6" for 1/2" Max. Rec. Loads shown include safety factory of 5. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 35 ™ www.tolco.com www.tolco.com Revision 8/13/2001 Revision 5/24/2001 ® a brand of Component of State of California OSHPD Approved Seismic Restraints System Fig. 109F - Concrete Insert Size Range — 3/8" thru 7/8" rod Material — Carbon Steel Function — Designed to be embedded in concrete to provide a point of support. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL) for 3/8" and 1/2". Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain anchor bolt with Electro-Galvanized hardware and plate. Note — For rod sizes 5/8" - 11⁄2" refer to Fig. 107F. Available in Stainless Steel or HDG finish on request. Order By — Figure number, rod size and finish. Note — The Hex or Jam Nut has NO value in determining the loads. Their function is to assist in locking the Coupling snug to the bottom of the deck form preventing the concrete from leaking into the coupling threads. Any other suitable locking device may be substituted if desired. Dimensions • Weights Design Load Vertical Design Load Shear Hard Rock Lt. Wt. Hard Rock Lt. Wt. Hard Rock Lt. Wt. Depth De min. (in.) 3/8 1/2 5/8 1255 2321 780 735 1392 468 978 978 1278 733 733 958 777 980 688 525 679 445 31⁄2 31⁄2 4 2 2 2 3/4 7/8 1346 2321 806 1392 1278 1278 958 958 927 1166 619 803 4 4 21⁄2 6 Rod Size 36 Design Load 45° “E” Embedment OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Component of State of California OSHPD Approved Seismic Restraints System Fig. 120 - “U” Hanger Size Range — Size 3/4" thru 8" pipe Material — Carbon Steel Function — Used to support piping from wood beams where no contraction is expected. Used extensively in automatic fire sprinkler systems. Approvals — Meets or exceeds the requirements of National Fire Protection Association (NFPA), Pamphlet 13. Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Maximum Temperature — 750°F Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size, length and finish Dimensions • Weights Pipe Size A Fastener Size Max Rec. Load Lbs.*** 3/4 1 11⁄4 5/16 5/16 5/16 16 x 2* 16 x 2* 16 x 2* 250 250 250 11⁄2 2 21⁄2 5/16 5/16 3/8 16 x 2* 16 x 2* 3/8 x 21⁄2** 250 250 320 3 31⁄2 4 5 6 8 3/8 3/8 3/8 1/2 1/2 1/2 3/8 3/8 1/2 1/2 1/2 5/8 21⁄2** 21⁄2** 3** 3** 3** 3** 320 560 560 560 760 x x x x x x * Drive screw ** Lag bolt *** With minimum safety factor of 5 Fastener schedule per NFPA OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 37 www.tolco.com www.tolco.com Revision 5/24/2001 Fig. 120RWA (Models A&B) Retrofit Wrap Around U-Hanger Clamp Component of State of California OSHPD Approved Seismic Restraints System Size Range — Model A 1" thru 2" pipe Model B 1" thru 8" pipe Material — Carbon Steel Function — Clamp Models “A” and “B” are designed to restrain movement of the pipe within standard U-hangers as is required by NFPA 13. Where retrofit capability is crucial, the Fig. 120RWA is a labor efficient alternative to the standard TOLCO™ Fig. 120W Wrap Around U-Hanger. Features — Model “A” is installed fast and easily by hand. No tools are necessary. Model “B” installs easily by tightening two hex nuts. Both Models feature a unique bracing slot that locks onto a standard U-hanger to become a solid unit that will stabilize the pipe during seismic activity or sprinkler head activation. Models “A” and “B” are designed to be used in retrofit or new construction applications. Both Models will clamp to existing U-Hangers without restriction to leg angle Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. NFPA 13 (1999) A-6-2.3.3. Finish — Model “A”, Galvanized. Model “B”, Plain and Galvanized. Consult factory for Stainless Steel material. Order By — Figure number, model, type numbers and pipe size Ordering Note — Order Model “A” by pipe size (1" thru 2"). Order Model “B” by the following type and pipe size: Type 1 — (1" and 11⁄4" pipe size) Type 2 — (11⁄2" and 2" pipe size) Type 3 — (21⁄2" and 3" pipe size) Type 4 — (4" pipe size) Type 6 — (5" and 6" pipe size) Type 8 — (8" pipe size) Important Note — The bracing slot feature is sized to fit the U-Hanger rod schedule as required by NFPA 13 as follows: 5/16" rod for up to 2" pipe 3/8" rod for 21⁄2" - 6" pipe 1/2" rod for 8" pipe For other rod size requirements consult factory. 38 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Model A Model B www.tolco.com Revision 1/13/2004 Fig. 130 - Beam Clamp with Bolt and Nut Size Range — Fig. 130-1 = TJI 35 Fig. 130-2 = — Fig. 130-3 = TJI 25 Fig. 130-4 = TJI 55 & 65 Fig. 130-5 = TJI 75 Fig. 130-6 = TJI 96 Material — Carbon Steel Function — Effective and economical method of hanging from “Trus Joist” type beams. Use with Fig. 102 Eye Rod. Approvals — Sizes 1, 2, 3 and 4 Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL) listed through 4" pipe. All Fig. 130 Beam Clamps meet requirements of Factory Mutual Engineering and NFPA 13, through 4" pipe. Finish — Electro-Galvanized Note — Available in HDG finish or Stainless Steel materials. Order By — Figure number with dash designation and finish or by H&W of beam and finish. Dimensions • Weights Size Beam Dimensions Approx. 130- A H W Wt./100 1 2 3 31⁄4 31⁄2 31⁄4 11⁄2 13⁄4 11⁄2 25⁄16 21⁄2 13⁄4 65 70 58 4 5† 6† 31⁄2 35⁄8 41⁄2 11⁄2 13⁄4 21⁄2 31⁄2 31⁄2 37⁄8 83 86 101 * Max. Rec. Load 500 lbs. **Safety Factor of 5 † Larger bolts and I-rods are required for 5" and 6" pipe sizes OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 39 ™ www.tolco.com www.tolco.com ® Revision 5/24/2001 Revision 5/24/2001 a brand of Fig. 200 - “Trimline” Adjustable Band Hanger Size Range — 1/2" thru 8" pipe Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. • (21⁄2" thru 8" Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Mil. Galvanized. For Stainless Steel materials, order TOLCO™ Fig. 200WON. Order By — Figure number and pipe size Dimensions • Weights Pipe Size 40 Rod Size Inch Metric A B Max. Rec. Load Lbs. Approx. Length 1/2 3/4 1 3/8 3/8 3/8 8mm or 10mm 8mm or 10mm 8mm or 10mm 31⁄8 31⁄8 33⁄8 25⁄8 21⁄2 25⁄8 400 400 400 11 11 12 11⁄4 11⁄2 2 3/8 3/8 3/8 8mm or 10mm 8mm or 10mm 8mm or 10mm 33⁄4 37⁄8 41⁄2 27⁄8 27⁄8 3 400 400 400 13 14 15 21⁄2 3 31⁄2 3/8 3/8 3/8 10mm 10mm 10mm 55⁄8 57⁄8 73⁄8 41⁄8 4 51⁄4 600 600 600 27 29 34 4 5 6 8 3/8 1/2 1/2 1/2 10mm 12mm 12mm 12mm 73⁄8 91⁄8 101⁄8 131⁄8 5 61⁄4 63⁄4 83⁄4 1000 1250 1250 1250 35 66 73 136 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/31/2001 Fig. 200H - Heavy Duty Band Hanger (for Trapeze) Size Range — 1/2" thru 4" trapeze pipe size. Used to support up to 8" pipe. Material — Carbon Steel — Pre-Galvanized to G40 Spec Function —Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features — Furnished with 3/8" or 1/2" adjusting threaded ring nut. Approvals — Underwriters’ Laboratories listed in the USA (UL) and Canada (cUL). Conforms to Federal Specification WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature — 650°F Finish — Pre-Galvanized Order By — Figure number, pipe size and rod size. Important Design Note — Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 41 www.tolco.com www.tolco.com Revision 5/24/2001 Fig. 200WON - “Trimline” Adjustable Band Hanger w/o Swivel Nut Size Range — 1/2" thru 8" pipe Material — Carbon Steel Function — Recommended for the suspension of fire sprinkler and non-insulated pipe or insulated pipe with Fig. 220 shield. Generally installed with two hex nuts. Features — Flared edges on sizes 1/2" thru 2". Eases installation and protects CPVC pipe from any abrasion. Approvals — Underwriters’ Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering approved. Conforms to Federal Specifications WW-171E, Type 7 and Manufacturers Standardization Society SP-69, Type 7 Maximum Temperature — 650°F Finish — Mil. Galvanized to G-90 Note — Available in Stainless Steel materials Order By — Figure number and pipe size Dimensions • Weights Pipe 42 Size Rod Size A B C Max. Rec. Load Lbs. Approx. Length 1/2 3/4 1 3/8 3/8 3/8 21⁄2 21⁄2 27⁄8 2 2 21⁄8 400 400 400 8 8 9 11⁄4 11⁄2 2 3/8 3/8 3/8 33⁄8 31⁄2 33⁄4 21⁄2 21⁄2 21⁄2 400 400 400 10 11 12 21⁄2 3 31⁄2 3/8 3/8 3/8 51⁄8 53⁄8 63⁄4 35⁄8 31⁄2 45⁄8 600 600 600 24 27 32 4 5 6 8 3/8 1/2 1/2 1/2 63⁄4 83⁄8 93⁄8 123⁄8 41⁄2 51⁄2 6 8 1000 1250 1250 1250 33 60 68 130 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Component of State of California OSHPD Approved Seismic Restraints System Fig. 324 - Pipe Roll Hanger Size Range — 21⁄2" thru 24" pipe Material — Cast iron and carbon steel Function — For supporting pipe where movement may occur due to thermal expansion. Approvals — Conforms to Federal Specification WW-H-171E, Type 44, 1" thru 20", and Manufacturers Standardization Society SP-69, Type 43. Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note — When pipe line is insulated, total outside diameter f pipe and covering should be used to determine size of anger; also see Figs. 260-1 to 265-4. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Dimensions • Weights Pipe Size Rod Size A B* C Max. Rec. Load Lbs. Approx. Wt./100 21⁄2 3 31⁄2 1/2 1/2 1/2 515⁄16 65⁄8 71⁄4 35⁄16 315⁄16 43⁄8 17⁄8 23⁄16 29⁄16 225 310 390 171 224 250 4 5 6 5/8 5/8 3/4 77⁄8 91⁄8 103⁄16 51⁄16 61⁄8 71⁄16 27⁄8 37⁄16 41⁄16 475 685 780 372 649 869 8 10 12 7/8 7/8 7/8 121⁄2 155⁄16 179⁄16 93⁄16 113⁄8 131⁄2 51⁄16 65⁄16 77⁄16 780 965 1200 1368 1909 3001 14 16 18 1 1 1 201⁄4 223⁄8 241⁄2 145⁄8 165⁄8 185⁄8 87⁄16 95⁄16 103⁄8 1200 1200 1400 3578 4150 5382 20 24 11⁄4 11⁄2 263⁄4 319⁄16 205⁄8 245⁄8 2611⁄16 1313⁄16 1600 1600 7317 12600 D OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 43 ™ www.tolco.com www.tolco.com ® Revision 5/24/2001 Revision 8/30/2002 a brand of Fig. 800 - Adjustable Sway Brace Attachment to Steel Size Range — 4" thru 18" beam width Material — Carbon Steel Function — Seismic brace attachment to steel. Features — This product’s design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure connection to steel where drilling and/or welding of brace connection could present structural issues. Comes completely assembled ready for installation. The Fig. 800 must be used with one of the TOLCO™ Fig. 900 series brace fittings (ordered separately). Installation Instructions — Tighten set bolts against flange until bolt head breaks off. Tighten hex head bolts into clamp body until lock washers are fully flat. Application Note — Allows bracing in either lateral or longitudinal direction. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, type number and size number. Important Structural Note: TOLCO Steel Fig. 65/66 components were used during structural testing and are required to achieve the listed results. Malleable iron components must never be substituted because of their serious potential for fracture and failure. Dimensions • Weights *Max. Design Loads/Lbs. Type 1 2 Flange Thickness Along Max. (In.) Beam 3/4 11⁄4 1265 1265 Across Beam 2015 2015 Dimensions • Weights *Max. Design Loads/Lbs. Size 1 2 3 4 5 6 7 44 Fits Beam Range (In.) 4 6 8 10 12 14 16 - 6 8 10 12 14 16 18 Along Beam Across Beam 1265 1265 1265 1265 1265 1265 1265 2015 2015 2015 2015 2015 2015 2015 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System www.tolco.com Revision 5/24/2001 Fig. 825 - Bar Joist Sway Brace Attachment Size Range — One size accommodates all TOLCO Fig. 900 Series sway brace attachments. Maximum Horizontal Design Load 2015 lbs. Material — Carbon Steel Function — *To attach sway and hanger assemblies bracing to steel bar joist structural members. Features — This product’s design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist. Break off head bolt design assures verification of proper installation. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Important Structural Note: The TOLCO Fig. 825 has significant UL established design loads, however, structural issues related to the steel joist member require restricted location installation for all bracing. Steel Joist Manufacturers require that all earthquake bracing connections be within 6" of the cord panel point. Installation of the Fig. 825 must be limited to the outer third sections of the joist span. For installations within the center third section of the joist span, use UL Listed TOLCO Fig. 825A. Finish — Plain, Electro-Galvanized and HDG Order By — Figure number and finish *Important Note — The Fig. 825 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 825 must be used only with other TOLCO bracing products. US Patent #6,098,942, Canada Patent #2,286,659 Component of State of California OSHPD Approved Seismic Restraints System Maximum Design Load 2015 Lbs. Weight/100 237.5 Lbs. UL Listed as Hanger Attachment 6" Pipe Max. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 45 www.tolco.com www.tolco.com Revision 5/24/2001 Fig. 825A - Bar Joist Sway Brace Attachment Size Range — One size accommodates all TOLCO Fig. 900 Series sway brace attachments. Maximum Horizontal Design Load 1265 lbs. Material — Carbon Steel Function — *To attach sway bracing to steel bar joist structural members. Features — This product’s design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist. Break off head bolt design assures verification of proper installation. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OHSPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Important Structural Note: The TOLCO Fig. 825A has significant UL established design loads, however, structural issues related to the steel joist member require restricted location installation for all bracing. Steel Joist Manufacturers require that all earthquake bracing connections be within 6" of the cord panel point. Installation of the Fig. 825A is not restricted to the two outer third sections of the joist. For greater design loads, refer to TOLCO Fig. 825. Finish — Plain Order By — Figure number and finish *Important Note — The Fig. 825A is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 825A must be used only with other TOLCO bracing products. Patent #6,098,942 46 Maximum Design Load 1265 Lbs. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Fig. 906 - Sway Brace Multi-Fastener Adapter Size Range — Use with 1" and 11⁄4" TOLCO UL listed 900 Series Earthquake Brace Attachments. Material — Carbon Steel Application — Allows sway brace fittings to develop greater load carrying ability by providing multiple fastener attachments. The National Fire Protection (NFPA) provides information on fastener loads to various structures. Refer to NFPA Pamphlet 13 (1996) Edition, Table 4-14.4.3.5.6. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) only when used with TOLCO 900 Series Earthquake Brace Attachments. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number and specify dimensions H1 and H2. Component of State of California OSHPD Approved Seismic Restraints System Dimensions • Weights A B C D H1 H2 Approx. Wt./100 12 9 2 1/4 Specify Specify Varies OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 47 ™ www.tolco.com www.tolco.com ® Revision 5/24/2001 Revision 05/05/2005 a brand of Fig. 907 - 4-Way Longitudinal Sway Brace Attachment Size Range — 1" x 1", 1" x 11⁄4" and 11⁄4" x 11⁄4" bracing pipe. Material — Carbon Steel, hardened cone (or cup) point engaging screw Function — For bracing pipe against sway and seismic disturbances, Functions as as longitudinal brace connection when attached to a lateral brace pipe. Bracing connection must be positioned as close as physically possible to the braced pipe (No more than 3" away). Must be used only with TOLCO bracing components. When used in conjunction with TOLCO Fig. 1000, this combination bracing restricts piping movement in tension and compression both laterally and longitudinally. Features — Universal swivel design allows the Fig. 907 to achieve any angle of attachment required. Pipe end requires no threads — simply slide bracing pipes through fittings and tighten each set screw until lock washer is fully compressed, or extends 20 ft.-lbs. Application Note — Length of bracing pipe per NFPA 13, Table 6-4.5.8 (L/ R=200); 1" schedule 40 pipe maximum 7’0": 11/4" schedule 40 pipe maximum 9’0". Alternative pipe materials are currently under review. Please consult factory. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, bracing pipe sizes and finish. Important Note — The Fig. 907 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 907 must be used only with other TOLCO bracing products. The Fig. 907 is not intended for use with the Fig. 1001 Sway Brace Attachment. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Dimensions • Weights Pipe Size A B Max. Design Load Lbs.* Approx. Wt./100 1x1 1 x 11⁄4 11⁄4 x 11⁄4 43⁄4 51⁄16 53⁄8 43⁄4 413⁄16 51⁄4 655* 655* 655* 103 107 109 * Load will accommodate up to 4" pipe at maximum spacing. 48 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System www.tolco.com Revision 5/24/2001 Fig. 909 - No-Thread Swivel Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range — 1" bracing pipe. For brace pipe sizes larger than 1", use TOLCO Fig. 980. Material — Carbon Steel, hardened cone point engaging screw Function — The structural component of a sway and seismic bracing system. Features — This product’s design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (1999 Edition) Table 6-4.5.9 indicates clearly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. All steel construction eliminates deficiencies associated with malleable type attachments. Fastener can be mounted to all surface angles. Application Note — The Fig. 909 is used in conjunction with the TOLCO Fig. 1000, Fig. 1001, or Fig. 4 (A) pipe clamp, and joined together with bracing pipe. Install per NFPA 13 and/or TOLCO State of California OSHPD Approved Seismic Restraint Manual. The required type, number and size of fasteners used for the structure attachment fitting shall be in accordance with NFPA 13 and/or OSHPD. Installation — Extend bracing pipe through opening. Tighten cone point engaging screw until head bottoms out or minimum torque 23 ft./lbs. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, pipe size and finish. Important Note — The Fig. 909 is precision manufactured to perform its function as a critical component of a complete bracing assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer’s installation instructions. To ensure performance, the UL Listing requires that the Fig. 909 must be used only with other TOLCO bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Dimensions • Weights Pipe Size A B H* Max. Design. Load Lbs. Max. Design Load Lbs. w/Washer Approx. Wt./100 1 6 15⁄8 17/32 2015 2765 91 * Available with hole sizes to accommodate up to 3/4" fastener. Consult Factory. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 49 www.tolco.com Revision 5/24/2001 Fig. 910 - Swivel Sway Brace Fitting Size Range — 1" and 11⁄4" bracing pipe. For brace pipe sizes larger than 11⁄4", use TOLCO Fig. 980. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; the Fig. 910 is used in conjunction with the Fig. 1001, Fig. 1000 or with a Fig. 4A Pipe Clamp and joined together with a brace pipe per NFPA 13. Features — This product’s design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (1999 Edition) Table 6-4.5.9 indicates clearly that fastener table load values are based only on concentric loading. Universal swivel design allows Fig. 910 to be attached at any surface angle. All steel construction. NFPA 13 (1999 Edition) Table 6-4.5.8: 1" Schedule 40 bracing pipe maximum 7’0". 11⁄4" Schedule 40 bracing pipe maximum 9’0". Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note — The Fig. 910 Swivel Attachment and the Fig. 1001, Fig. 1000, or Fig. 4A Pipe Clamp make up a sway brace system of (UL) Listed attachments and bracing materials which satisfies the requirements of Underwriters’ Laboratories and the National Fire Protection Association (NFPA). Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number, pipe size and finish. Note — Specific weight load conditions may require more than one fastener to the building surface. Sway brace attachments may be ordered with multiple and/or larger fastener mounting holes. Consult the factory. The Fig. 910 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 910 must be used only with other TOLCO bracing products. Component of State of California OSHPD Approved Seismic Restraints System Dimensions • Weights 50 Pipe Size A B C D Hole Size E F Max. Design Load Lbs. Approx. Wt./100 1 11⁄4 2 13⁄16 11⁄2 15⁄16 3 3 9/16 9/16 25⁄16 25⁄16 2 25⁄16 2015 2015 88 99 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com ™ www.tolco.com ® Revision 5/24/2001 a brand of Fig. 975 - Straight Sway Brace Fitting Size Range — 1" bracing pipe. For brace pipe sizes larger than 1", use TOLCO Fig. 980. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbances. The building attachment component of a sway brace system; the Fig. 975 is used in conjunction with the Fig. 1000, Fig. 1001 or with a Fig. 4A Pipe Clamp and joined together with a brace pipe per NFPA 13. Features — Open design allows for easy checking of thread engagement. All steel construction eliminates deficiencies associated with malleable type attachments. Application Note — Length of bracing pipe per National Fire Protection Association Pamphlet NFPA 13, Table 4-5.4.3.5.1(B): 1" Schedule 40 bracing pipe maximum 7’0". Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Figure number and finish. Note — Specific weight load conditions may require more than one fastener to the building surface. Sway brace attachments may be ordered with multiple and/or larger fastener mounting holes. Consult the factory. Use Fig. 975 in straight position only. Bending of this fitting alters the material strength. Use Fig. 909 or Fig. 910 when angle fitting is required. Important Note — The Fig. 975 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 975 must be used only with other TOLCO bracing products. Dimensions • Weights Pipe Size A B C Hole Size Max. Design Load Lbs. Approx. Wt./100 1 4 31⁄2 11⁄2 9/16 2015 88 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 51 www.tolco.com Revision 3/28/2003 Fig. 980 - Universal Swivel Sway Brace Attachment Component of State of Size Range — One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, and all structural California OSHPD Approved steel up to 1/4" thick. Seismic Restraints System Material — Carbon Steel Function — Multi-functional attachment to structure or braced pipe fitting. Features — This product’s design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (1999 Edition) Table 6-4.5.9 H indicates clearly that fastener table load values are based only on concentric loading. Fits multiple sizes of bracing pipe, strut or structural steel. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Application Note — Install per NFPA 13 and/or TOLCO A State of California (OSHPD) Approved Seismic Restraint Manual. B Installation — Place bracing component into jaw fully and tighten bolt until head breaks off. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note — The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000 , Fig. 2001 or Fig. 4A Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters’ Laboratories and the National Fire Protection Association (NFPA) Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number and finish. Important Note — The Fig. 980 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 980 must be used only with other TOLCO bracing products. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Dimensions • Weights * 52 A B H* Max. Design Load Lbs. Approx. Wt./100 51⁄4 17⁄8 17/32 2765 132 Available with hole sizes to accommodate up to 3/4" fastener. Consult factory. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/5/2006 Fig. 981 - Fast Attach — Universal Swivel Sway Brace Attachment Component of State of Size Range — One size fits bracing pipe 1" thru 2", TOLCO 12 gauge channel, California OSHPD Approved Seismic Restraints System and all structural steel up to 1/4" thick. Material — Carbon Steel Function — Multi-functional attachment to hanger rod, trapeze rod, structure or braced pipe fitting. Features — Fits multiple sizes of bracing pipe, strut or structural steel. Swivel allows adjustment to various surface angles. Break-away bolt head assures verification of proper installation torque. Unique “fast attach” yoke design allows Fig. 981 to be installed using hanger rods 3/8" through 3/4" in size. “Stackable” design allows installation of both lateral and longitudinal braces, as well as opposing braces, to be easily installed on a single hanger rod, with no disassembly. The retrofit yoke has a visual verification of proper installation torque. Tighten existing hex nut down until the slight gap in the yoke assembly closes completely. Installation — The Fig. 981 is the “braced pipe” attachment component of a lateral or longitudinal brace assembly. It is intended to be combined with the pipe hanger, all-thread rod, “bracing pipe” and TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 and or OSHPD guidelines should be followed. To Install — Spin nut on top of hanger counterclockwise to loosen the nut and raise it above the top of the hanger. Attach Fig. 981 by slipping the open side of the 981 yoke onto the all thread rod above the top of the hanger. Be sure that the concave indented side of the Fig. 981 yoke is facing upward away from the top of the hanger toward the loosened hex net. Spin the hex nut clockwise and tighten securely. Insert brace pipe into the jaw of the 981 and tighten the cone point set bolt until the hex head breaks off ensuring proper installation torque. Pivot brace pipe to proper angle and attach to structure using a TOLCO swivel structural attachment Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraint Systems Guidelines, approved by the California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Electro-Galvanized Note — Available in Electro-Galvanized finish. Order By — Figure number, rod size 3/8" thru 3/4" and finish. US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Dimensions • Weights A B C D Max. Design Load Lbs. Approx. Wt./100 51⁄8 41⁄8 11⁄4 21⁄4 2015 88 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 53 www.tolco.com www.tolco.com Revision 5/24/2001 Component of State of California OSHPD Approved Seismic Restraints System Fig. 990 - Cable Sway Brace Attachment Size Range — 1/8", 3/16" and 1/4" pre-stretched cable. 3/8" thru 11⁄4" hanger rod bolt or fastener. Material — Carbon Steel Function — Cable attachment for sway bracing. Attaches sway brace to structure or to hanger. To be used with 7 x 19 strand core pre-stretched galvanized aircraft cable. Features — Cable easily slides into oversized front arch opening. Breakaway hex nuts assure verification of proper installation. Will mount to any surface angle. Approvals — Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint System Guidelines. Finish — Electro-Galvanized Order By — Figure number, cable size and mounting hole size. Note — Order 990H for hanger rod, bolt or fastener hole size 1" thru 11⁄4". Dimensions • Weights Cable Diameter A B 1/8" 3/16" 1/4" 45⁄16" 5" 5" 2" 21⁄4" 25⁄8" Maximum Design Load Lbs. 975* 2050* 3150* * Maximum load rating controlled by cable breaking strength. 54 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/15/2005 Fig. 991 - Fast Attach — Cable Sway Brace Attachment Size Range — 1/8", 3/16" and 1/4" pre-stretched cable. Fits rod size 3/8" thru 3/4". Material — Carbon Steel Function — Cable attachment for sway bracing. Attaches sway brace to hanger rod. To be used with 7 x 19 strand core pre-stretched galvanized aircraft cable. Features — Fits multiple sizes of cable. Cable easily slides into oversized front arch opening. Swivel allows adjustment to various surface angles. Break-away hex nuts assure verification of proper installation torque. Unique “Fast-Attach” yoke design allows Fig. 991 to be installed using hanger rods 3/8" through 3/4" in size. “Stackable” design allows installation of both lateral and longitudinal braces, as well as opposing braces, to be easily installed on a single hanger rod, with no disassembly. The retrofit yoke has a visual verification of proper installation torque. Tighten existing hex nut down until the slight gap in the yoke assembly closes completely. Approvals — Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint System Guidelines. Finish — Electro-Galvanized Order By — Figure number, rod size 3/8" through 3/4" US AND INTERNATIONAL PATENT APPLICATION IN PROCESS. Component of State of California OSHPD Approved Seismic Restraints System Dimensions • Weights Cable Diameter A B 1/8" 3/16" 1/4" 53⁄4" 63⁄4" 63⁄4" 21⁄8" 21⁄2" 21⁄2" Maximum Design Load Lbs. 975* 2050* 3150* * Maximum load rating controlled by cable breaking strength. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 55 www.tolco.com www.tolco.com Revision 5/24/2001 Fig. 1000 - “Fast Clamp” Sway Brace Attachment Size Range — Pipe size to be braced: 1" thru 6" Schedule 10 thru 40.* Pipe size used for bracing: 1" and 11⁄4" Schedule 40 IPS. * Additionally (UL) approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 — 8 ft. lbs. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1000 is used in conjunction with a TOLCO™ Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13* or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features — Can be used to brace Schedules 7 thru 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of bracing pipe. Can be used as 4-way riser brace. Can be used as longitudinal brace with Fig. 907. All steel construction eliminates structural deficiencies associated with casting type sway brace fittings. Comes assembled and individually packaged with illustrated installation instructions — sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Application Note — Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond the Fig. 1000 is recommended. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Order first by pipe size to be braced, followed by pipe size used for bracing, figure number and finish. Important Note — The Fig. 1000 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 1000 must be used only with other TOLCO bracing products. Component of State of California OSHPD Approved Seismic Restraints System Maximum Design Load 1" thru 4" pipe size — 2015 lbs. 6" size — 1265 lbs. TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. 56 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 8/01/2003 Fig. 1001 - Sway Brace Attachment Component of State of Size Range — Pipe size to be braced: 21⁄2" thru 8" IPS.* Pipe size used California OSHPD Approved 1 for bracing: 1" and 1 ⁄4" Schedule 40 IPS. Seismic Restraints System Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: The Fig. 1001 is used in conjunction with a TOLCO™ 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features — *Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note — Position Fig. 1001 over the pipe to be braced Maximum Design Load and tighten two hex head cone point set bolts until heads bottom Sch 7 - 1600 lbs. out. A minimum of 1" pipe extension is recommended. Sch 10 & 40 w/1" Brace Pipe - 2015 lbs. Approvals — Underwriters Laboratories Listed in the USA (UL) Sch 10 & 40 w/11⁄4" Brace Pipe - 2765 lbs. and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note — The Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 1001 must be used only with other TOLCO bracing products. The Fig 1001 is not intended for use with the Fig. 907 4-Way Longitudinal Brace Attachment. NATIONAL AND INTERNATIONAL PATENT APPLICATION IN PROCESS OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 57 www.tolco. Revision 8/30/2002 Fig. 2002 - Sway Brace Attachment Size Range — Pipe size to be braced: 21⁄2" thru 8" all steel schedules, copper, plastic, FRP, cast iron and ductile iron. Consult factory when bracing other than steel. The Fig. 2002 accepts brace pipes sizes 11⁄2" and 2" steel schedule 10 through schedule 40. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: The Fig. 2002 is used in conjunction with a TOLCO™ 900 Series sway brace attachments and joined together with bracing pipe. Install per NFPA 13 and/or TOLCO State of California OSHPD Approved Seismic Restrain Manual. Features — Unique design will not damage thin wall, plastic, copper or ductile iron pipe. Easy verification of proper installation by tightening bolts until ears touch. Installation — Place Fig. 2002 over pipe to be braced. Slide bracing pipe through attachment and tighten hex nuts until ears touch. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Figure number, pipe size to be braced, pipe size used for bracing (11⁄2" or 2") and finish. Important Note — The Fig. 2002 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that the Fig. 2002 must be used only with other TOLCO bracing products. 58 Component of State of California OSHPD Approved Seismic Restraints System Maximum Design Load 2015 Lbs. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/24/2001 Reference Material Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 59 www.tolco.com Revision 5/24/2001 TOLCO Cross Reference Chart 60 TOLCO GRINNELL B-LINE MCO PHD SUPER STRUT CARPENTER & PATERSON EMPIRE INDUSTRIES 1 1A 1CBS 1C.I. 1F 1LD 1LDF 1PVC 1LDPVC 1V 2 2F 2FWON 2WON 3 3F 4 4A 4B 4C.I. 4F 4H 4L 4PVC 5 6 6F 6PVC 7 8 9 9X 14 14X 20 20S 21 21F 22 23 24 25 27A 28 30 30L 30M 30H 31-M 31-O 32 33 34 35 40 41 42 260 300 — 590 — 65 — — — — — — — — 67 — 212 212FP — — — 216 — — 295 261 — — 103 100 600 599 595 594 262 — — — — — — — — — 194 — 195 199 — — — 47 49 52 — — — B3100 B3108 — B3102 B3100F B3104 B3104F B3100C B3104C B3106 B3170 B3170NFF B3172F B3172 B3690 B3690F B3140 — — — — B3142 — — B3144 B3373 — B3373C B3148 B3149 B3132 B3132W B3134 B3134W B3180 B3256 — — — — — — — — B3068 — B3066 B3067 — — B3147 B3084 B3086 B3085 B3190 B3191 — 400 415 — 405 400FL 410 410FL 420 — — 100 100FL — 105 418 418FL 450 — — — — 451 — — 452 510 — 520 700 705 517 516 — — — — 8EG — 107 108 109 — — — 348 351 352 353 — — 712 373 374 374A 457 458 319 450 430 — 420 450F 440 440F 453 — 450V 151 151F 180F 180 970 97-F 520 — — — — 522 — — 525 550 — 553 535 545 580 585 590 595 825 830 — — — — — — — — — 850 855 860 — — 840 — 904 903 820 810 910 C710 CX710 — CI1710 C710F CL710 — C710P — — C727 C727F C725 C727 C711 C711F C725 — — — — — — — C726 C720 — C720P C720L CX725 C724 W724 — — 164 — — — — — — — — — C736 — C739M C739H — — RCS — — — C704A C704 — 100 100EL — 100C.I. — 200 — 100PVC — 200VT 800 — — — — — 175 — — — — 298 — — 304 126 — 126PVC 179 267 159 258 158DB 260 114 — — — — — — — — — 69 — 84 139 — — 127 — — — 227 227S 152 11 11X — 11CI — 110 — 110PC — 11V 31 — — — — — 212 — — — — 216 — — 189 50 — 49PC 95 97 97 599 595 75 231 180 — — — — — — — — 820 — 801 802 — — — — 67 68 146 145 53 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/24/2001 TOLCO Cross Reference Chart TOLCO GRINNELL B-LINE MCO PHD SUPER STRUT CARPENTER & PATERSON EMPIRE INDUSTRIES 50 51 52 58 60 61 61T 62 64 65 66 68 69 69R 70 70R 70S 71 78 81 81PVC 82 82PVC 83 84 99 100 101 101L 102 102L 103 104 105 106 107 107F 108 109 109F 110 111 113 114 115 116 117 118 119 120 120MJ 120RWAA 120RWAB 120W 122 123 124 202 206 — — 227 — — 133-134 95 92 93 93 89, 87 — 135 136R — 135 128R CT65 — CT121 — — — — 146 278 278X 248 248X 140 — 142 — — — — — — 137 120 — — — — — 60 — — — — — — — — — B3060 — B3070 — — B3042 — B3050 B351L — B3033 B3033 B3367 — B655 B656 — B3220 B3199 B3104CT B3104CTC B3373CT B3373CTC B3195CT B3195CT — — B3211 B3211X B3210 B3210X B3205 B3212 B3213 — — — — B3019 B2501 B3188 B3501 — — — B3234 — B3248 — — — — — — — — — 325 — 326 — — 359 — 361 200 300 310 — 255C — 25 25R 26S — — 402 — 511 — — — 51 50 40W — 40 — — — — 46 — — — 370A — 150 — 10 10H 11 — 13 340 12 — — — — — — — — — — 925 — — — — 610, 620 250 350 — 360 359 — 100 105 104 — 940 442 — 552 554 982 980 10 20 55 — 50 — 15 60 40 — 70 — — 885 — 90 95, 110 110 110H 130 135 134 960 136 80 — — — — — — — 540 AB201 542 — — — — C755T-C757T C775L C777 C778 M778 U568 — H119 H119R — — M742R CTL710 — CT720 — C716 — — H104 E157 — E156 — — — E151 — — — — C745 — H115 HL115 E145 — E147 — E148 C781 EF147 — — — — — — — — 303 — — — 45 6 — 15 238 192 — — 18 — 123 123R — 123W 95 100CT 100PVC 126CT — — — 94 — 93 341 22 306 133 31 28 — 177 — — — — 283 222 165 103 103 706 176 102 — 44 — — — — — 59 — 202 — — — 159 158 — 218 21L 62 61 — 22R — 51 51R — — — 110CT 110PC 50CT 50CTI or 59PC — — 54 — 26W — 26 — 57 — 55 — 77 — 81 — — 137 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 56 52 52 72 52L 75 52F — — — — — — 83 84 61 ™ www.tolco.com www.tolco.com ® Revision 5/24/2001 Revision 5/24/2001 a brand of TOLCO™ Cross Reference Chart 62 TOLCO GRINNELL B-LINE MCO PHD SUPER STRUT CARPENTER & PATERSON EMPIRE INDUSTRIES 125 126 130 200 200WON 202 203 207 209 210 219 220 244H 244HR 244C 244CR 260-1 261-11/2 262-2 263-21/2 264-3 265-4 301CT 302 303 304 305 306 307 309 309N 310 310N 312 313 315 316 316T 317 317/319 318/319 318 322 323 324 325 326 327 328 329 330 331 332 333 335 336 337 — — — 69 — CT69 — — — — 168 167 — — — — 160 161 162 163 164 165 CT138R 138R 108 66 66 114 110R 181 — 282 285N 102 191 — — — — 264 — 259 171 — 181 175 177 271 274 218, 229 290 230 299 157 217 14 — DS16 B3228 — B3170NF 105 B3170CT B3170CTC — — — — B3151 — — — — B3160 B3161 B3162 B3163 B3164 B3165 B3198HCT B3198H B3173 B3083WO B3083WO B3224 B3222 B3014 B3014N B2500 N2500 B3096 B3092 B3093 B3088 B3088T B3095 B3093 B3092 B3090 B3114R B3121 B3110 B3120 B3122 B3117SL B3118SL B3054 B3200 B3202 B3201 B3203 B3045 B3040 B3082 43 42 356 130 — 101 102 — — — — 125 126 — 127 — 630 631 632 633 634 635 456 455 — 320L 320W — 47 282 282N 355 355N — 724 722 — — 720 — — 721 605 621 610 615 620 617 619 360 35 30 31 26 369 363 321 48 45 — — — E151D E150S — — — CT727 CT727P — — — — C790 — — — — C789 C789A C789B C789C C789D C789E MT718 M718 — C789W/O C780W/HW — E120 — — 452 AB102 — — C786 — — — C786 — C785 — C729-2½ C729-2 CR729A RC729 C730C C730D M732 E120A F112 F111 M129 C769 — C747 166 — — 800 1A 800CT 800PVC — — — — 265P — — — — 351 352 353 354 355 356 81CT — — — — 38 12 — 650-266-75 — — 137 — 137 — — — — — 125 — 110 140 39 109 — 53 293 — 132 276 — 92 14 — 59 — — 31 310 C10CTI — — — — — 167 — — — — 1900 1901 1902 1903 1904 1905 41HCT 41H — — — 114 47 — — — — 422 — 425 or 427 — — 420 426 427 427 277 271 272 275 274 279S 280S 229 131 320 909 157 156 155 — 153 — 47W 47D 160 170 165 — 165 — 651 653 654 655 656 658 512H 508 500 900-1 900 44 32 950 950N — — 875 880 882 — 871 880 875 876 882 490 — 470 460 480 486 487 630 35 960 38 25 — 635 — OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/24/2001 TOLCO™ Cross Reference Chart TOLCO GRINNELL B-LINE MCO PHD SUPER STRUT CARPENTER & PATERSON EMPIRE INDUSTRIES 343 405 406 420 421 421C 422 425 426 427 428 429 430 431 432 500 505 506 568 580 581 582 598 650 800 825 825A 906 907 909 910 975 980 981 990 991 1000 1001 2002 55 — — — 256 — 255 — 280 436 437 438-1 438-2 438-3 — 178 247 — B268 80-V 81H 82A-G 98A-G 296 — — — — — — 112 — — — — — — — — B3080 B3256 B3257 — B3281 — — — B3891 — — B3891 B3892 B3893 371 — — 650 651 — — — 640 — — 640-1 640-2 640-3 — 625 — — — — — — — — — — — — — — 335AB 335A — — — — — — — 936 — — — 670-678 — — — 690 — — 690-1 690-2 690-3 — — — — — — — — — — — — — — — — — 890 — — — — — — — — — — — — PG794 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 220 — — — — — — — — — — — — — — 478 — — 568 — — — — — — — — — — — — — — — — — — — — 69 — — — — — — — 4000 Series — — 4100 Series — — — — — 35 — — — — — — — — — — — — — — — — — — — — — B3264 — — — — — — — — — — — — — — — — — — — — — — — OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 63 ™ www.tolco.com ® Revision 5/24/2001 a brand of Cross Reference Chart - Grinnell to TOLCO™ 64 GRINNELL TOLCO GRINNELL TOLCO GRINNELL TOLCO GRINNELL TOLCO 14 47 49 52 55 60 65 CT65 66 67 69 CT69 80-V 81H 82A-G 89, 87 92 93 95 98A-G 100 103 108 110R 112 114 120 CT121 CT138R 128R 133-134 135 136R 137 138R 140 142 146 157 160 161 162 163 164 336 33 34 35 343 118 1LD 81 305 3 200 202 580 581 582 69 65 66 64 598 8 7 303 307 910 306 111 82 301CT 78 62 70, 71 70R 110 302 103 105 100 333 260-1 261-11/2 262-2 263-21/2 264-3 178 181 191 192 194 195 199 202 206 212 212FP 216 217 227 230 247 248 248X 255 256 257 259 260 261 262 264 B268 271 274 278 278X 280 282 285N 290 295 296 299 300 436 437 438-1 438-2 438-3 500 324 313 312 30 30M 30H 50 51 4 4A 4H 335 60 331 505 102 102L 422 421 426 318 1 6 20 317/319 568 327 328 101 101L 426 309, 309N 310N 330 5 650 332 1A 427 428 429 430 431 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1CBS 1F 1LDF 2 2F 2FWON 2WON 3F 4B 4C.I. 4F 6F 20S 21 21F 22 23 24 25 30L 31M 31O 32 40 41 42 52 58 61 69R 70S 83 84 99 104 106 107 107F 108 109 109F 113 114 115 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 120W 122 123 124 125 126 130 200WON 203 207 209 210 244H 244HR 244C 244CR 315 316 317 316T 318/319 323 337 405 406 420 421 425 432 506 800 825 825A 906 907 909 975 980 981 990 991 1000 1001 2002 165 167 168 171 175 177 265-4 220 219 322 325 326 590 594 595 599 600 218, 229 1C.I. 14X 14 9X 9 329 — — — — — — 116 117 119 120 120MJ 120RWA OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com www.tolco. Revision 5/24/2001 Cross Reference Chart - B-Line to TOLCO™ B-LINE TOLCO B-LINE TOLCO B-LINE TOLCO B-LINE TOLCO DS16 B351L B655 B656 B2500 N2500 B2501 B3014 B3014N B3019 B3033 B3040 B3042 B3045 B3050 B3054 B3060 B3066 B3067 B3068 B3070 B3080 B3082 B3083WO B3083 B3084 B3085 B3086 B3088 B3088T B3090 B3092 B3093 B3095 B3096 B3100 B3100C B3100F B3102 B3104 B3104C B3104CT B3104CTC B3104F B3106 B3108 B3110 B3114 B3117SL B3118SL 125 64 70 70R 310 310N 109F 309 309N 109 68 336 61 335 62 329 50 30M 30H 30 52 343 337 304 305 33 35 34 316 316T 318 318/319 317/319 317 312 1 1PVC 1F 1C.I. 1LD 1LDPVC 81 81PVC 1LDF 1V 1A 324 322 327 328 B3121 B3122 B3132 B3132W B3134 B3134W B3140 B3142 B3144 B3147 B3148 B3149 B3151 B3160 B3161 B3162 B3163 B3164 B3165 B3170 B3170CT B3170CTC B3170NFF B3172 B3172F B3173 B3180 B3188 B3190 B3191 B3195CT B3198H B3198HCT B3199 B3200 B3201 B3202 B3203 B3205 B3210 B3210X B3211 B3211X B3212 B3213 B3220 B3224 B3228 B3234 B3248 323 326 9 9X 14 14X 4 4H 5 32 7 8 220 260-1 216-11/2 262-2 263-21/2 264-3 265-4 2 202 203 2F 2WON 2FWON 303 20 110 40 41 83 302 301CT 78 330 332 331 333 103 102 102L 101 101L 104 105 71 306 126 116 118 B3256 B3257 B3264 B3281 B3367 B3373 B3373C B3373CT B3373CTC B3501 B3690 B3690F B3891 B3892 B3893 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 405 406 500 421 69 6 6PVC 82 82PVC 111 3 3F 426 430 431 1CBS 4A 4B 4C.I. 4F 6F 20S 21 21F 22 23 24 25 30L 31M 31O 42 51 58 60 65 66 69R 70S 84 99 100 106 107 107F 108 113 114 115 117 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 120 120MJ 120RWA 120W 122 123 124 130 200 200WON 207 209 210 219 244H 244HR 244C 244CR 420 421C 422 425 427 428 432 505 506 568 580 581 582 598 650 800 825 825A 906 907 909 910 975 980 981 990 991 1000 1001 2002 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 65 ™ www.tolco.com ® Revision 5/24/2001 a brand of Cross Reference Chart - MCO to TOLCO™ 66 MCO TOLCO MCO TOLCO MCO TOLCO MCO TOLCO 8EG 10 10H 11 12 13 25 25R 25S 26 30 31 35 40 40W 42 43 46 47 50 51 100 100FL 102 105 125 126 127 130 150 200 255C 282 282N 300 310 319 320L 320W 321 325 326 335A 335AB 340 348 351 352 353 355 355N 21 113 114 115 119 117 70 70R 70S 333 331 332 330 102 101 126 125 106 307 100 99 2 2F 203 200WON 220 244H 244C 200 110 64 69 309 309N 64 66 42 304 305 337 50 52 975 910 118 30 30L 30M 30H 310 310N 356 359 360 361 363 367 370A 371 373 374 374A 400 400FL 402 40 410 410FL 41 418 418FL 450 451 452 455 456 457 458 470 510 511 516 517 605 610 615 617 619 620 621 625 630 631 632 633 634 635 640 640-1 640-2 640-3 651 130 61 329 62 336 335 109 343 33 34 35 1 1F 81 1C.I. 1LD 1LDF 1A 3 3F 4 4H 5 302 301CT 40 41 20 6 82 9X 9 322 324 325 327 328 326 323 500 260-1 261-11/2 262-2 263-21/2 264-3 265-4 426 429 430 431 421 651 700 705 712 720 721 722 724 — 420 — — — — — — — — 520 — — — — 107 108 109 — — — — — — — — — — — — — — — — — — — — — — — — — 421 7 8 32 317 318 315 313 1CBS 1PVC 1LDPVC 1V 2FWON 4A 4B 4C.I. 4F 6F 6PVC 14 14X 20S 21F 22 23 24 25 31M 31O 51 58 60 68 69R 71 78 81PVC 82PVC 83 84 101l 102L 103 104 107 107F 108 109F 111 116 120 — — — — — — — 101 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 120MJ 120RWAA 120RWAB 120W 122 123 124 202 207 209 210 219 244HR 244CR 303 306 312 316 316T 317/319 318/319 405 406 421C 422 425 427 428 432 505 506 568 580 581 582 598 650 800 825A 906 907 909 980 981 990 991 1000 1001 2001 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com ™ www.tolco.com ® Revision 5/24/2001 a brand of Cross Reference Chart - PHD to TOLCO™ PHD TOLCO PHD TOLCO PHD TOLCO PHD TOLCO 10 15 20 25 32 35 38 40 44 45 47D 47W 48 50 55 60 70 80 90 95, 110 100 104 105 110 110H 130 134 135 136 151 151F 153 160 165 170 180 180F 250 350 359 360 420 430 440 440F 450 450F 450V 453 460 470 99 103 100 333 307 330 332 105 306 126 210 209 125 102 101 104 107 120 110 111 70 70S 70R 113 114 115 117 116 119 2 2F 203 219 244H/244C 220 2WON 2FWON 64 65 69 69 1C.I. 1A 1LD 1LDF 1 1F 1V 1PVC 325 324 480 486 487 490 500 508 512H 520 522 525 535 545 550 552 553 554 580 585 590 595 610, 620 630 635 651 653 654 655 656 658 670-678 690 810 820 825 830 840 850 855 860 871 875 876 880 882 885 890 900 900-1 903 904 910 326 327 328 322 303 302 301CT 4 4H 5 7 8 6 82 6PVC 82PVC 9 9X 14 14X 62 329 336 260-1 261-11/2 262-2 263-21/2 264-3 265-4 421 426 41 40 20 20S 32 30L 30M 30H 316T 317/319 318/319 317 318 109 975 305 304 35 34 42 925 930 936 940 950 950N 960 970 970F 980 982 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 52 118 343 78 309 309N 331 3 3F 84 83 1CBS 1LDPVC 4A 4B 4PVC 4C.I. 4F 4L 6F 21 21F 22 23 24 25 28 30 31M 31O 33 50 51 58 60 61 61T 66 69R 71 81PVC 101L 102L 106 107F 108 109F 120MJ 120RWAA 120RWAB 120W — — — — — — — — — — — — — — — — — — — — — — — 690-1 690-2 690-3 — — — — — — — — — — — — — — — — — — — — — — — 122 124 130 200 200WON 202 207 244HB 244CR 310 310N 316 323 335 337 405 406 420 421C 422 425 427 428 429 430 431 432 500 505 506 568 580 581 582 598 650 800 825 825A 906 907 909 910 980 981 990 1000 1001 2002 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 67 www.tolco.com Revision 5/24/2001 Cross Reference Chart - Super Strut to TOLCO™ 68 SUPER STRUT TOLCO SUPER STRUT TOLCO SUPER STRUT TOLCO AB102 F111 F112 H104 H115 H119 H119R HL115 E120 E120A M129 E145 E147 EF147 E148 E150S E151 E151D E156 E157 164 AB201 C475 452 540 542 U568 C704 C704A C710 C710F C710P CI710 CL710 CTL710 CX710 C711 C711F C716 M718 C720 C720L C720P CT720 C724 W724 C725 C725 C726 C727 C727 310N 332 331 100 110 70 70R 111 307 330 333 113 115 119 117 126 105 125 102 101 20 51 109 310 50 52 69 41 40 1 1F 1PVC 1C.I. 1LD 81 1A 3 3F 83 302 6 7 6PVC 82 9 9X 2FWON 4 5 2 2WON C727F CT727 CT727P C729-2 C729-2½ CF729A RC729 C730C C730D M732 C736 C739H C739M M742R C747 C755T-C757T C777 C769 C775L C778 M778 C780W/HW C780W/O C781 C785 C786 C789 C789A C789B C789C C789D C789E C790 PG794 RCS — — — — — — — — — — — — — — — — 2F 202 203 324 323 325 326 327 328 329 30 30H 30M 78 337 62 65 335 64 66 68 305 304 118 318 317/319 260-1 260-11/2 262-2 263-21/2 264-3 265-4 220 421 32 1CBS 1LDF 1LDPVC 1V 4B 4C.I. 4F 4H 4L 4PVC 6F 14 20S 21 21F 22 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 23 24 25 28 30L 31M 31O 33 34 35 42 58 60 61 61T 69R 70S 71 81PVC 82PVC 84 89 101L 102L 103 104 106 107 107F 108 109F 114 116 120 120MJ 120RWA 120W 122 123 124 130 200 200WON 207 209 210 219 244HR 244C 244CR 303 SUPER STRUT TOLCO — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 306 309 309N 312 313 316 316T 317 318/319 322 336 343 405 406 420 421C 422 425 426 427 428 429 430 431 432 500 505 506 568 580 581 582 598 650 800 825 825A 906 907 909 910 975 980 981 990 991 1000 1001 2002 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com ™ www.tolco.com ® Revision 5/24/2001 a brand of Cross Reference Chart - Carpenter & Paterson to TOLCO™ CARPENTER & CARPENTER & CARPENTER & CARPENTER & TOLCO TOLCO TOLCO PATERSON PATERSON PATERSON PATERSON 6 12 14 15 18 28 31 33 38 39 44 45 53 59 69 84 85 92 93 94 100 102 103 109 110 114 123 125 126 127 132 133 137 137 139 140 152 158 165 166 175 176 177 179 192 200 220 222 227 258 260 61 307 336 62 69 105 104 102 306 325 120 60 328 123 30 30M 78 335 101 99 1 118 115 326 323 20 70 318 6 32 331 103 312 315 30H 324 42 9 113 125 4 117 107 7 65 1LD 343 111 40 9X 14X 267 276 283 293 298 303 304 306 341 351 352 353 354 355 356 399 478 706 800 800 100C.I. 100CT 100EL 100PVC 100PVC 123R 123W 126CT 126PVC 158DB 1A 200VT 227S 265P 650-266-75 800CT 800PVC 81CT — — — — — — — — — — — — — 8 332 110 329 4H 50 5 102L 101L 260-1 260-11/2 262-2 263-21/2 264-3 265-4 568 500 116 2 200 1C.I. 81 1A 1PVC 81PVC 70R 71 82 6PVC 14 200WON 1V 41 220 309N 202 203 301CT 1CBS 1F 1LDF 1LDPVC 2F 2FWON 3 3F 4A 4B 4C.I. 4F 4L — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 4PVC 6F 20S 21 21F 22 23 24 25 27 27A 28 30L 31-M 31-O 33 34 35 51 52 58 61T 66 68 69R 70S 82PVC 83 84 100 106 107F 108 109 114 119 120MJ 120RWAA 120W 122 124 126 130 207 209 210 219 244H 244HR 244C 244CR — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com TOLCO 302 303 304 305 309 310 310N 313 316 316T 317 317/319 318/319 322 327 330 333 337 405 406 421 421C 422 425 426 427 428 429 430 431 432 505 506 580 581 582 598 650 800 825A 906 907 910 975 980 981 990 991 1000 1001 2002 69 www.tolco.com Revision 5/24/2001 Cross Reference Chart - Empire Industries to TOLCO™ 70 EMPIRE INDUSTRIES TOLCO EMPIRE INDUSTRIES TOLCO EMPIRE INDUSTRIES TOLCO 11 26 31 31 35 47 50 51 52 53 54 55 56 57 59 61 62 67 68 69 72 75 75 77 80 81 83 84 95 97 110 114 137 145 146 150 155 156 157 158 159 167 180 189 202 212 216 218 229 231 255 256 1 102 2 200 506 307 6 70 115 42 99 105 113 103 125 66 65 34 35 343 116 14X 118 107 209 108 123 124 7 8 1LD 306 110 41 40 130 336 335 333 61 60 220 20S 5 50 4 4H 62 329 20 421C 421 271 272 273 275 277 310 320 420 422 426 427 427 595 599 600 801 802 320 909 1900 1901 1902 1903 1904 1905 110CT 110PC 110PC 11CI 11V 11X 131 21L 22R 26W 279S 280S 310CTI 4000 Series 4100 Series 41H 41HCT 425 or 427 49PC 50CT 50CTI or 49PC 51R 52F 52L 81N — — 323 324 326 325 322 200WON 331 317 312 317/319 318/319 318 14 9X 9 30M 30H 30 332 260-1 260-11/2 262-2 263-21/2 264-3 265-4 81 1PVC 81PVC 1C.I. 1V 1A 330 64 69 101 327 328 202 426 429 302 301CT 313 6PVD 82 82PVC 70R 119 117 309N 1CBS 1F — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1LDF 1LDPVC 2F 2FWON 3 3F 4A 4B 4C.I. 4F 4L 4PVC 6F 21 21F 22 23 24 25 27 27A 28 30L 31-M 31-O 33 51 52 58 61T 68 69R 70S 71 78 83 84 100 101L 102L 104 106 107F 109 109F 111 114 120 120MJ 120RWAA 120W 122 EMPIRE INDUSTRIES TOLCO — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 126 203 307 210 219 244H 244HR 244C 244CR 303 304 305 309 310 310N 315 316 316T 337 405 406 422 425 427 428 430 431 432 500 505 568 580 581 582 598 650 800 825A 906 907 909 910 975 980 981 990 991 1000 1001 2002 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com www.tolco.com Revision 5/24/2001 TOLCO to MSS and Federal Specification Cross Reference TOLCO 1 1A 1LD 2 2NFPA 2WON 3 4 4 CI 4H 5 6 20 20S 30L 30M 30H 62 64 65 66 68 81 82 110 200 200WON 202 203 220 260-1 261-11⁄2 MSS-SP-69 Federal Spec. Ww-H-171E Type 1 Type 1 — Type 10 Type 10 Type 7 Type 5 Type 4 Type 4 Type 4 Type 3 Type 8 Type 26 Type 26 Type 31 Type 32 Type 33 Type 21 Type 23 Type 19 Type 19 Type 19 — Type 8 Type 24 Type 10 Type 7 Type 10 Type 10 Type 40 Type 39 Type 39 Type 1 Type 1 Type 12 Type 10 Type 10 Type 7 — Type 4 Type 4 Type 4 Type 3 Type 8 Type 26 Type 26 Type 32 Type 33 Type34 Type 21 Type 23 Type 23 Type 23 Type 23 Type 12 Type 8 Type 24 Type 10 Type 7 Type 10 Type 10 Type 41 Type 40A & 40B Type 40A & 40B TOLCO MSS-SP-69 Federal Spec. Ww-H-171E 262-2 263-21⁄2 264-3 265-4 301CT 302 303 304 305 306 307 309 310 317 318 317A 322 324 327 328 329 330 331 332 335 336 343 499 500 568 580 582 598 650 Type 39 Type 39 Type 39 Type 39 Type 12 Type 12 Type 11 Type 22 Type 22 Type 15 Type 16 Type 18 Type 18 Type 36 Type 37 Type 38 Type 41 Type 43 Type 44 Type 46 Type 30 Type 17 Type 13 Type 14 Type 25 Type 27 Type 57 Type 58 Type 49 Type 51 Type 54 & 55 Type 51 Type 51 Type 50 Type 40A & 40B Type 40A & 40B Type 40A & 40B Type 40A & 40B Type 25 Type 25 Type 11 Type 22 Type 22 Type 15 Type 16 Type 18 Type 19 Type 37 Type 38 Type 39 Type 42 Type 44 Type 45 Type 47 Type 30 Type 17 Type 13 Type 14 Type 53 Type 54 — — Type 50 Type 51 Type 52 Type 51 Type 51 — OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 71 ™ www.tolco.com ® Revision 5/24/2001 a brand of Beam Dimensions American Standard Channels — C Shapes Designation Flange Depth & Wt. Width "x" Lbs. "Y" C3 C3 C3 C4 C4 C5 C5 C6 C6 C6 C7 C7 C7 C8 C8 C8 C9 C9 C9 C10 C10 C10 C10 C12 C12 C12 C15 C15 C15 C18 C18 C18 C18 72 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 4.1 5.0 6.0 5.4 7.25 6.7 9.0 8.2 10.5 13.0 9.8 12.25 14.75 11.5 13.75 18.75 13.4 15.0 20.0 15.3 20.0 25.0 30.0 20.7 25.0 30.0 33.9 40.0 50.0 42.7 45.8 51.9 58.0 13⁄8 11⁄2 15⁄8 15⁄8 13⁄4 13⁄4 17⁄8 17⁄8 2 21⁄8 21⁄8 21⁄4 21⁄4 21⁄4 23⁄8 21⁄2 21⁄2 21⁄2 25⁄8 25⁄8 23⁄4 27⁄8 3 3 3 31⁄8 33⁄8 31⁄2 33⁄4 4 4 41⁄8 41⁄4 Ave. Thickness "Z" .250 .313 .313 .375 .375 .375 .438 .438 .500 .625 .625 American Standard I Beams — S Shapes Designation Flange Depth & Wt. Width "x" Lbs. "Y" S3 S3 S4 S4 S5 S5 S6 S6 S7 S7 S8 S8 S10 S10 S12 S12 S12 S12 S15 S15 S18 S18 S20 S20 S20.3 S20.3 S24 S24 S24 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 5.7 23⁄8 7.5 21⁄2 7.7 25⁄8 9.5 23⁄4 10.0 3 14.75 31⁄4 12.5 33⁄8 17.25 35⁄8 15.3 35⁄8 20.0 37⁄8 18.4 4 23.0 41⁄8 25.4 45⁄8 35.0 5 31.8 5 35.0 51⁄8 40.8 51⁄4 50.0 51⁄2 42.9 51⁄2 50.0 55⁄8 54.7 6 70.0 61⁄4 66.0 61⁄4 75.0 63⁄8 86.0 7 96.0 71⁄4 80.0 7 90.0 71⁄8 100.0 71⁄4 Ave. Thickness "Z" .250 .313 .313 .375 .375 .438 .500 .563 .688 .625 .688 .813 .938 .875 American Standard Wide Flange — W Shapes Designation Flange Depth & Wt. Width "x" Lbs. "Y" W4 W5 W6 W8 W8 W8 W8 W8 W8 W8 W8 W8 W8 W10 W10 W10 W10 W10 W10 W10 W10 W10 W10 W10 W12 W12 W12 W12 W12 W12 W12 W12 W12 W12 W12 W12 W12 W12 W14 W14 W14 W14 W14 W14 W14 W14 W14 W14 W14 x 13 x 19 x 25 x 18 x 21 x 24 x 28 x 31 x 35 x 40 x 48 x 58 x 67 x 22 x 26 x 33 x 39 x 45 x 49 x 54 x 60 x 68 x 77 x 88 x 26 x 30 x 35 x 40 x 45 x 50 x 53 x 58 x 65 x 72 x79 x 87 x 96 x 106 x 30 x 34 x 38 x 43 x 48 x 53 x 61 x 68 x 74 x 82 x 90 4 5 51⁄8 51⁄4 51⁄4 61⁄2 61⁄2 8 8 81⁄8 81⁄8 81⁄4 81⁄4 53⁄4 53⁄4 8 8 8 10 10 101⁄8 101⁄8 101⁄4 101⁄4 61⁄2 61⁄2 61⁄2 8 8 81⁄8 10 10 12 12 121⁄8 121⁄8 121⁄8 121⁄4 63⁄4 63⁄4 63⁄4 8 8 8 10 10 101⁄8 101⁄8 141⁄2 Ave. Thickness "Z" .375 .430 .455 .330 .400 .400 .465 .435 .495 .560 .685 .810 .935 .360 .440 .435 .530 .620 .560 .615 .680 .770 .870 .990 .380 .440 .520 .515 .575 .640 .575 .640 .605 .670 .735 .810 .900 .990 .385 .455 .515 .530 .595 .660 .645 .720 .785 .855 .710 Designation Flange Depth & Wt. Width "x" Lbs. "Y" W14 W14 W14 W14 W16 W16 W16 W16 W16 W16 W16 W16 W16 W18 W18 W18 W18 W18 W18 W18 W18 W18 W21 W21 W21 W21 W21 W21 W21 W21 W24 W24 W24 W24 W24 W24 W27 W27 W27 W27 W30 W30 W30 W30 W33 W33 W33 W36 W36 W36 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x 99 109 120 132 36 40 45 50 57 67 77 89 100 50 55 60 65 71 76 86 97 106 62 68 73 83 93 101 111 122 76 84 94 104 117 131 94 102 114 146 108 116 134 132 118 130 141 135 150 160 145⁄8 145⁄8 145⁄8 143⁄4 7 7 7 71⁄8 71⁄8 101⁄4 101⁄4 103⁄8 103⁄8 71⁄2 71⁄2 71⁄2 75⁄8 75⁄8 11 111⁄8 111⁄8 111⁄4 81⁄4 81⁄4 81⁄4 83⁄8 83⁄8 121⁄4 123⁄8 123⁄8 9 9 91⁄8 123⁄4 123⁄4 127⁄8 10 10 101⁄8 14 101⁄2 101⁄2 101⁄2 101⁄2 111⁄2 111⁄2 111⁄2 12 12 12 Ave. Thickness "Z" .780 .860 .940 1.030 .630 .505 .565 .630 .715 .665 .760 .875 .985 .570 .630 .695 .750 .810 .680 .770 .870 .940 .615 .685 .740 .835 .930 .800 .875 .960 .680 .770 .875 .750 .850 .960 .745 .830 .930 .975 .760 .850 .930 1.000 .740 .855 .960 .790 .940 1.020 ™ www.tolco.com ® Revision 5/24/2001 a brand of ™ Decimals of a Foot Inch 0" 0 1/16 1/8 3/16 1/4 5/16 3/8 7/16 1/2 9/16 5/8 11/16 3/4 13/16 7/8 15/16 0 .0052 .0104 .0156 .0208 .0260 .0313 .0365 .0417 .0469 .0521 .0573 .0625 .0677 .0729 .0781 1" 2" 3" 4" 5" 6" 7" 8" 9" 10" 11" .0833 .0085 .0938 .0990 .1042 .1094 .1146 .1198 .1250 .1302 .1354 .1406 .1458 .1510 .1563 .1615 .1667 .1719 .1771 .1823 .1875 .1927 .1979 .2031 .2083 .2135 .2188 .2240 .2292 .2344 .2396 .2448 .2500 .2552 .2604 .2656 .2708 .2760 .2812 .2891 .2917 .2969 .3021 .3073 .3125 .3177 .3229 .3281 .3330 .3385 .3438 .3490 .3542 .3594 .3646 .3724 .3750 .3802 .3854 .3906 .3958 .4010 .4063 .4118 .4167 .4219 .4271 .4323 .4375 .4427 .4479 .4557 .4583 .4635 .4688 .4740 .4792 .4844 .4896 .4948 .5000 .5052 .5104 .5156 .5208 .5260 .5313 .5391 .5417 .5469 .5521 .5573 .5625 .5677 .5729 .5781 .5833 .5885 .5938 .5990 .6042 .6094 .6146 .6224 .6250 .6302 .6354 .6406 .6458 .6510 .6563 .6615 .6667 .6719 .6771 .6823 .6875 .6927 .6979 .7057 .7083 .7135 .7188 .7240 .7292 .7344 .7396 .7448 .7500 .7552 .7604 .7656 .7708 .7760 .7813 .7891 .7917 .7969 .8021 .8073 .8125 .8177 .8229 .8221 .8333 .8385 .8438 .8490 .8542 .8594 .8646 .8724 .8750 .8802 .8854 .8906 .8958 .9010 .9063 .9115 .9167 .9219 .9271 .9323 .9375 .9427 .9479 .9557 .9583 .9635 .9688 .9740 .9792 .9844 .9896 .9948 Decimals of an Inch Fraction Decimal 1/32 1/16 3/32 1/8 5/32 3/16 7/32 1/4 9/32 5/16 11/32 3/8 13/32 7/16 15/32 1/2 .0312 .0625 .0937 .1250 .1562 .1875 .2187 .2500 .2812 .3125 .3437 .3750 .4062 .4375 .4687 .500 Fraction Decimal 17/32 9/16 19/32 5/8 21/32 11/16 23/32 3/4 25/32 13/16 27/32 7/8 29/32 15/16 31/32 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com .5312 .5625 .5937 .6250 .6562 .6875 .7187 .7500 .7812 .8125 .8437 .8750 .9062 .9375 .9687 73 www.tolco.com Revision 5/24/2001 Steel Pipe Data Schedule 40 & 80 Pipe Size Sched. No. 3/8 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 1/2 3/4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4 Wall Wt. Per Water Weight Thickness Foot per Ft./Lbs O.D. .675 .840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 .091 .126 .109 .147 .113 .154 .133 .179 .104 .191 .145 .200 .154 .218 .203 .276 .216 .300 .226 .318 .237 .337 .567 .738 .850 1.087 1.130 1.473 1.678 2.171 2.272 2.996 2.717 3.631 3.652 5.022 5.790 7.660 7.570 10.250 9.110 12.510 10.790 14.980 .083 .061 .132 .101 .230 .186 .374 .311 .647 .555 .882 .765 1.452 1.279 2.072 1.834 3.200 2.860 4.280 3.850 5.510 4.980 Pipe Size Sched. No. 5 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 20 API 6 8 10 12 14 16 18 20 24 30 36 O.D. 5.563 6.625 8.625 10.750 12.750 14.000 16.000 18.000 20.000 24.000 30.000 36.000 Wall Wt. Per Water Weight Thickness Foot per Ft. Lbs. .258 .375 .280 .432 .322 .500 .365 .593 .406 .687 .437 .750 .500 .843 .563 .937 .593 1.031 .687 1.218 .500 .500 14.620 20.780 18.970 28.570 28.550 43.390 40.480 64.400 53.600 88.60 63.00 107.000 83.000 137.000 105.000 171.000 123.000 209.000 171.000 297.000 158.000 190.000 8.660 7.870 12.510 11.290 21.600 19.800 34.100 31.100 48.500 44.000 58.500 51.200 76.500 69.700 97.200 88.500 120.400 109.400 174.200 158.200 286.000 417.000 Copper Tube Data Type L Type K Nom. Tube Size O.D. Tubing O.D. 1/4 3/8 1/2 5/8 3/4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4 5 6 3/8 1/3 5/8 3/4 7/8 11⁄8 13⁄8 15⁄8 21⁄8 25⁄8 31⁄8 35⁄8 41⁄8 51⁄8 61⁄8 .375 .500 .625 .750 .875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 74 Wall Wt. Per Water Weight Thickness Foot per Ft./Lbs .030 .035 .040 .042 .045 .050 .055 .060 .070 .080 .090 .100 .110 .125 .140 .126 .198 .285 .362 .455 .655 .884 1.140 1.75 2.480 3.330 4.290 5.380 7.610 10.200 .034 .062 .100 .151 .209 .357 .546 .767 1.341 2.064 2.949 3.989 5.188 8.081 11.616 Nom. Tube Size O.D. Tubing O.D. 1/4 3/8 1/2 5/8 3/4 1 11⁄4 11⁄2 2 21⁄2 3 31⁄2 4 5 6 3/8 1/2 5/8 3/4 7/8 11⁄8 13⁄8 15⁄8 21⁄8 25⁄8 31⁄8 35⁄8 41⁄8 51⁄8 61⁄8 .375 .500 .625 .750 .875 1.125 1.375 1.625 2.125 2.625 3.125 3.625 4.125 5.125 6.125 Wall Wt. Per Water Weight Thickness Foot per Ft. Lbs. .035 .049 .049 .049 .065 .065 .065 .072 .083 .095 .109 .120 .134 .160 .192 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com .145 .269 .344 .418 .641 .839 1.040 1.360 2.050 2.920 4.000 5.120 6.510 9.670 13.870 .032 .055 .094 .144 .188 .337 .527 .743 1.310 2.000 2.960 3.900 5.060 8.000 11.200 www.tolco.com Revision 5/24/2001 a brand of Cast Iron Pipe Data American Water Works Assn. (AWWA) Mechanical Joint Pipe Class 150. Approximately same weight for Bell & Spigot. Flanged cast iron pipe add weight of flanges Pipe Size 3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 O.D. C.I. Pipe 3.96 4.80 6.90 9.05 11.10 13.20 15.30 17.40 19.50 21.60 25.80 32.00 38.30 44.50 50.80 Wall Thickness .32 .35 .38 .41 .44 .48 .51 .54 .58 .62 .73 .85 .94 1.05 1.14 Wt. Per Foot 12.2 16.4 25.7 36.7 48.7 62.9 78.8 95.0 114.7 135.9 190.4 277.3 368.9 479.1 595.2 Standard No Hub “Soil Pipe” Pipe Size 2 3 4 5 6 8 10 O.D. I.D. 2.25 3.25 4.25 5.25 6.25 8.38 10.50 1.89 2.89 3.89 4.87 5.85 7.94 9.98 Wt. of Water per Ft./Lbs. 3.73 5.72 12.80 23.10 35.50 51.00 69.30 90.30 114.00 141.50 201.00 312.00 449.00 612.00 803.00 Extra Heavy “Soil Pipe” Pipe Size 2 3 4 5 6 8 10 O.D. I.D. 2.38 3.50 4.50 5.50 6.50 8.62 10.75 2.00 3.00 4.00 5.00 6.00 8.00 10.00 Load Carrying Capacities of Threaded Steel Rod Rod Diameter In. 3/8 1/2 5/8 3/4 7/8 1 11/8 11/4 11/2 13/4 2 21/2 21/2 * Root Area Thread Sq. In. .068 .126 .202 .302 .419 .552 .693 .889 1.293 1.744 2.300 3.023 3.719 Max. Safe Load in Lbs. @650°F* 610 1130 1810 2710 3770 4960 6230 8000 11630 15700 20700 27200 33500 Max. Rec. Load in Lbs. @ 750°F* 540 1010 1610 2420 3360 4420 5560 7140 10370 14000 18460 24260 29800 Weight per Ft./Lbs. .376 .668 1.040 1.500 2.400 2.670 3.380 4.170 6.010 8.180 10.680 13.520 16.960 Maximum recommended load based on minimum safety factor of 5. Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 951.737.5599 • Fax: 951.737.0330 Customer Service • 800.786.5266 www.tolco.com Fittings Wrot and cast copper pressure fittings • Wrot and cast copper drainage fittings • Wrot copper PEXlink® fittings • Cast copper alloy flared fittings • Cast copper alloy flanges • ABS and PVC DWV fittings • Schedule 40 PVC pressure fittings • CPVC CTS fittings • CPVC CTS-to-metal transition fittings • Schedule 80 PVC and CPVC systems • CPVC metric piping systems Valves & Actuation Pressure-rated bronze, iron and alloy-iron gate, globe and check valves • Pressure-rated bronze ball valves • Boiler specialty valves • Commercial and industrial butterfly valves • Circuit balancing valves • Carbon and stainless steel ball valves • ANSI flanged steel ball valves • Pneumatic and electric actuators and controls • Grooved ball and butterfly valves • High performance butterfly valves • UL/FM fire protection valves • Low-pressure gate, globe, check and ball valves • Bronze specialty valves • Frostproof sillcocks • Quarter-turn supply stops • MSS specification valves • PVC ball valves • CPVC CTS ball valves • Just Right® recirculating valves Chemtrol® Thermoplastic pipe, valves and fittings in PVC, Corzan® CPVC, polypropylene and PVDF Kynar® • Chem-Aire® thermoplastic compressed air piping systems • Pneumatic and electric actuation systems Corzan® is a registered trademark of Noveon, IP Holdings Corp. Kynar® is a registered trademark of ATOFINA Chemical, Inc. Supporting the Flow. ™ eNIBCO® A suite of services designed to make customers more efficient • More cost-effective • More informed • EDI—Electronic Data Interchange • VMI—Vendor Managed Inventory • NIBCO.com • NIBCOpartner.com • eNIBCO will continuously develop new products to deliver the competitive advantage. Every solution begins with TOLCO . ™ TOLCO™ Office / Manufacturing 1375 Sampson Avenue Corona, California 92879 USA Phone: Fax: 951.737.5599 951.737.0330 We're committed to supporting all of your flow Pipe Hangers • Pipe Supports TOL-Strut Channel • Seismic Bracing ™ Customer Service: Phone: 800.786.5266 control needs. We can provide creative solutions for your most challenging bracing and support applications. Solutions that make your installations easier, safer and more cost-effective. For solutions that will support your flow-control applications, call on us. We're TOLCO, a product line committed to quality, service and innovation— Supporting the Flow. C-TOLFP-0105 www.tolco.com NIBCO INC. World Headquarters 1516 Middlebury Street Elkhart, IN 46515-1167 USA Customer Service: Phone: 800.234.0227 Fax: 800.234.0557 Technical Service: Phone: 888.446.4226 www.nibco.com