Spec Sheet

advertisement
GLA-UPS
Green Light® Uninterruptible Power Supply
The GLA-UPS provides a complete protection solution for Green Light
systems. In the event of a power failure, the GLA-UPS includes an
auto-restart feature that eliminates the need to perform an on-site
restart of the system. In addition, the GLA-UPS features a
recycle/reset button with sequential outlet start-up for proper system
rebooting.
> 60-second delay-on AC outlet
> Battery backup, surge protection and EMI/RFI filtering
> 3 widely-spaced AC outlets
> Recycle/reset button with sequential outlet start-up
> IEC power input connector accepts included 6-inch power
cord
> Diagnostic/Overload LEDs
> Resettable circuit breaker prevents dangerous system
overloads
> Auto-restart capability eliminates the need to perform an
on-site restart
> 550VA/300 watts standby UPS system
SPECIFICATIONS
TELCO OUT: (2) 4-pin RJ11 female;
Protected dual-line telephone/modem device connections
CABLE IN: (1) F-type coaxial, female;
Coaxial cable or antenna source connection
CABLE OUT: (1) F-type coaxial, female;
Protected TV/receiver or modem device connection
G: (1) Binding post, chassis ground lug
INPUT 120V 47-63Hz 12A : (1) IEC-320 C14 chassis plug;
Line Power Input, mates with 6 in power cord, included
UPS/Power Conditioner
Buttons
Output Power Capacity: 300 Watts (550 VA) @ 115/120 Volts AC nominal
Output Frequency Regulation: LINE MODE: passes line frequency of 60Hz
+/-10%
BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz
Waveform Type: Sine wave
Transfer Time: 4 milliseconds
Power Line Surge Protection: Rated for 1038 Joules
Filtering: EMI / RFI AC noise suppression
Voltage Regulation: BATTERY MODE: PWM sine wave output 115V +/-5%
Maximum Output Current: 12 Amps per outlet, 12 Amps total
LED Indicators
Power Requirements
Input Voltage: 120 Volts AC
Input Frequency: 60 Hz
Rated Input Current (at max load): 10 Amps
Recommended Electrical Service: 15 Amps 120 Volts
ON/OFF : (1 green) lights continuously to indicate that the UPS is ON and
supplying AC power (Utility or BATT)
OVERLOAD/CHECK BATTERY: (1 red) lights continuously after self test to
indicate capacity of the battery-supported outlets has been exceeded
Environmental
Temperature: 32° to 104°F (0° to 40°C)
Humidity: 10% to 95% RH (non-condensing)
Heat Dissipation: 31.5 BTU/Hr (AC mode, full load); 223.9 BTU/Hr (Battery
mode, full load)
Dimensions
Battery
Internal Battery: 12 Volts
Backup Runtime: ~10 minutes @ half load (150 Watts);
~3 minutes @ full load (300 Watts)
Recharging Time: < 9 hours from 10% to 90%
Battery Life: 3 to 6 years under normal use
Connectors
AUX: (2) NEMA 5-15R female;
Grounded AC power outlets, switched
MODEM: (1) NEMA 5-15R female
ROUTER: (1) NEMA 5-15R female;
Grounded AC power outlets, delayed-switched
TELCO IN: (1) 4-pin RJ11 female;
Dual-line telephone line connection
www.crestron.com
Power/Test: (1) Turns all output banks on or off, forces cold-start to battery
when held
Circuit Breaker (rear): Disrupts power to all outputs in case of an overload
condition, press to reset
800.237.2041
Height: 8.4 in (21.2 cm)
Width: 6.8 in (17.2 cm)
Depth: 3 in (7.5 cm)
GLA-UPS
GLA-UPSGreen
Green Light® Uninterruptible Power Supply
Weight
7.8 lb (3.5 kg)
Crestron Electronics, Inc. 15 Volvo Drive | Rockleigh, NJ 07647
Tel: 800.237.2041 / 201.767.3400 | Fax: 201.767.1905
www.crestron.com
All brand names, product names and trademarks are the property of their respective owners.
©2016 Crestron Electronics, Inc. | 15 Volvo Drive | Rockleigh, NJ 07647
Specifications subject to change without notice. 10/2/2016
Download