gate products

advertisement
Models SL 1000, SW 2000, & BG 3000
Wiring Specifications
Wiring Type
Wiring Gauge
Maximum Distance
Power Wiring
12 AWG Wire
300 Feet
10 AWG Wire
500 Feet
8 AWG Wire
750 Feet
6 AWG Wire
1000 Feet
4 AWG Wire
2000 Feet
16 - 24 AWG
3000 Feet
Control Wiring
SL 1000
Dual
(Shielded Wire Recommended)
16 –18 AWG
3000 Feet
(Twisted & Shielded Wire Mandatory)
Dual Operation Interconnections
Recv 1
Recv 2
Xmit 1
Xmit 2
Recv 1
Main Unit
Input
Manual Inputs
Cycle
Fire
Exit Loop
Shadow Loop
Inside/Outside Interrupt
Interrupt Bar
Inside/Outside Photo
Radio
Maglock
24 Vac Terminal – X3 Only
Recv 2
Xmit 1
Xmit 2
Secondary Unit
Hardware Features
Terminal
TB2
TB9
TB9
TB10
TB10
TB16
TB11
TB3
TB6
TB4
TB7
Intended Use
Three Button Control (Does not activate Timer)
Access Controls/Telephone Entry Systems
Fire Department Entrance Switch
External Exit Loop Vehicular Detector
Shadow Loop Detector Input
External Vehicular Detection Loop Input
Miller or Gate Edge Input
Photo Eye entrapment protection Input
Radio Receiver Systems
Control Relay for Magnetic Locks
Accessory Power up to 200mA (Ex. Loop Detectors)
Adjustments
B3
X3
Part Numbers B3 = SN1110168; X3 = SN1110173
Right Obstruction Sensitivity
R78
R89
Current Sensitivity Threshold During Opening*
Left Obstruction Sensitivity
R81
R160
Current Sensitivity Threshold During Closing*
Start-Up Sensitivity
R119
R203
Current Sensing Delay Time at Startup
Reclose Timer
R94
N/A
Time Delay Before Closing
Processor Board
* Right Hand Operation – S2 switch set to the right
Doc 01-20246, Rev D
SL 1000, SW 2000, & BG 3000
Programming Settings B3 Series @ Switch S1
Timer
ATG (Anti-Tailgate)
Main Unit or Single/Secondary Unit
Operator Type
Swing
Slide
Barrier
Linear
S1 - 3
Off
On
Off
On
S1 – 1
S1 – 2
S1 – 5
On - Timer Enabled
On - ATG Enabled
On - Main or Single
Off – Timer Disabled
Off – ATG Disabled
Off – Secondary Unit
Dual Operation
S1 - 4
On
Off
Off
On
BI-part
BI-part Latch
Tandem
Trap
S1 - 6
On
On
Off
Off
S1 - 7
Off
On
Off
On
Programming Settings X3 Series
To Enter Programming
Step
-
Input
Enter * * * + 0 0 0 0 0 0 + #
Factory Default
—
To Program
-
Step Number + Input + #
—
To Verify
-
Step Number + # (= Input)
—
To Exit Programming
00
00+#
—
Gate Type
01
0 - Slide, 1 - Swing, 2 – Barrier, 3 Linear
0
Unit Type
02
0 - Single, 1 – Main Unit, 2 – Secondary Unit
0
Pair Type
03
0 - Bipart, 1 - Bipart Latch, 2 – Not Used, 3 - Tandem
0
ATG (Anti-tailgate)
06
0 - Off, 1 – On
0
Reclose Time
08
0 - Disable, 1 - 250 Seconds
30
Obstruction Sense (close)
11
12 - 499 Inches Of Backup During “Close” Cycle
12
Obstruction Sense (open)
12
12 - 499 Inches Of Backup During “Open” Cycle
12
Interrupt Bar (closing)
13
12 - 499 Inches Of Backup During “Close” Cycle
12
Interrupt Bar (opening)
14
12 - 499 Inches Of Backup During “Open” Cycle
12
Return to Factory Default
15
101010 Partial, 191919 Complete
—
Set Password
17
Set Date, Day & Time
19
Any Combination of 6 Digit Numbers
yy+mm+dd+d(ay)+HH+MM
ex: 00+05+09+3+16+30 equates to Tuesday May 9,
2000 @ 4:30 PM
000000
—
At LiftMaster, we are Dedicated to
Outstanding Service and Superior Quality.
SW 2000
Doc 01-20246, Rev D