NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD (B) Qualified Person Endorsement : T LTA Endorsement : Project Title : STANDARD INSTALLATION DETAILS Drawing Title : TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (POB/LINKWAY/TAXI STAND/BUS SHELTER) Designed TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (POB / LINKWAY / TAXI STAND / BUS SHELTER) NURLY Scale SCALE: NTS N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1001 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1001-.dgn Sheet 1 of 1 A4 NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD(B) Qualified Person Endorsement : LTA Endorsement : Project Title : STANDARD INSTALLATION DETAILS Drawing Title : TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER/LINKWAY) Designed TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER / LINKWAY) NURLY SCALE: NTS Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1002 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1002-.dgn Sheet 1 of 1 A4 NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD(B). Qualified Person Endorsement : LTA Endorsement : Project Title : STANDARD INSTALLATION DETAILS Drawing Title : TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER) Designed TYPICAL SINGLE LINE DIAGRAM FOR NEW OG-BOX (BUS SHELTER) NURLY SCALE: NTS Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1003 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1003-.dgn Sheet 1 of 1 A4 NOTES: 1. CONTRACTOR IS RESPONSIBLE TO REPLACE ITEM * TO A 32A RATING AND PROVIDE THE LINKWAY VICINITY AS SHOWN IN SLD(B). Qualified Person Endorsement : T LTA Endorsement : Project Title : STANDARD INSTALLATION DETAILS Drawing Title : TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (DBO BUS SHELTER/POB/LINKWAY/TAXI STAND) Designed NURLY TYPICAL SINGLE LINE DIAGRAM FOR EXISTING OG-BOX (DBO BUS SHELTER / POB / LINKWAY / TAXI STAND) Scale Checked MALVIN HO Drawn Approved MELVYN THONG Date SCALE: NTS N.T.S. JULI JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1004 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1004-.dgn Sheet 1 of 1 A4 LAND TRANSPORT AUTHORITY LOGO UV RESISTANT WINDOW C/W NEOPRENE SEAL NAME PLATE LAND TRANSPORT AUTHORITY LOGO CONTRRACT NO: SERIAL NO: YEAR MANUFACTURE: SPANNERS INTERNATIONAL PTE LTD 6 CHANGI NORTH STREET 1 SPANNERS BUILDING SINGAPORE 498825 ISO Certified 9002Company WEATHERPROOF TO IP 54 ABLOY MASTER KEY FOR POWERGRID 300 2 NOS. POWER GRID KWH METER ABLOY MASTER KEY AS PER LTA’s REQUIREMENTS REMOVEABLE PLATE Qualified Person Endorsement : PLINTH C/W OPENING FOR CABLE ENTRY 2 NOS 50mm HEAVY DUTY UPVC PIPE FOR POB ELECTRICAL DISTRIBUTION LTA Endorsement : 2 NOS 100mm HEAVY DUTY uPVC LEAD IN C/W 90^ LONG BEND PIPES FOR POWER GRID INCOMING CABLING SIDE VIEW FRONT INTERNAL VIEW EXTERNAL VIEW 2 NOS 50mm HEAVY DUTY uPVC PIPE FOR FUTURE BUS SHELTER ELECTRICAL DISTRIBUTION Project Title : STANDARD INSTALLATION DETAILS TYPICAL DETAIL OF OG-BOX SCALE: NTS Drawing Title : TYPICAL DETAIL OF POB OG-BOX Designed NURLY Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1005 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1005-.dgn Sheet 1 of 1 A4 Back EXTERNAL BACK DOOR FIX PLATE 100mm HEAVY DUTY UPVC PIPE FOR POB/LINKWAY ELECTRICAL DISTRIBUTION 2 NOS 100mm HEAVY DUTY UPVC LEAD IN C/W 90^ LONG BEND PIPES FOR POWER GRID INCOMING CABLING PARTITION 100mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ELECTRICAL DISTRIBUTION SUPPORT FOR BREAKER GLASS PARTITION 50mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ADVERTISING PANEL EXTERNAL FRONT DOOR EXTERNAL FRONT DOOR Front PLAN VIEW Overall Length = min 1120mm Depth = min 450mm Depth = min 450mm Overall Length = min 1120mm 420 POWER POWER GRID GRID 1 KWH 1 KWH METER METER Qualified Person Endorsement : GLASS GLASS POB/LINKWAY SUPPORT FOR BREAKER FIX PLATE BUS SHELTER LTA Endorsement : BI Supply and Installed By PG EXTERNAL FRONT DOOR PARTITION REMOVABLE PLATE REMOVABLE PLATE REMOVABLE PLATE Project Title : Y STANDARD INSTALLATION DETAILS 2 NOS 100mm HEAVY DUTY UPVC LEAD IN C/W 90^ LONG BEND PIPES FOR POWER GRID INCOMING CABLING PLINTH C/W OPENING FOR CABLE ENTRY 50mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ADVERTISING PANEL 100mm HEAVY DUTY UPVC PIPE FOR BUS SHELTER ELECTRICAL DISTRIBUTION 100mm HEAVY DUTY UPVC PIPE FOR POB/LINKWAY ELECTRICAL DISTRIBUTION EXTERNAL BACK VIEW EXTERNAL VIEW INTERNAL SIDE VIEW INTERNAL FRONT VIEW Drawing Title : TYPICAL DETAIL OF POB OG-BOX SIDE VIEW Designed A NURLY Scale TYPICAL DETAIL OF OG-BOX N.T.S. SCALE: NTS Drawing No. : Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Rev. - L/ROAD/MES/SD/1006 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1006-.dgn Sheet 1 of 1 A4 1 2 3 7500 750 3000 3000 1500 1500 750 1500 1500 EARTH PIT (TOTAL RESISTANCE < 10ohm) MS ANGLE ROOF FASCIA TO ENGR’S DTL A M.S. RHS POST UNDERNEATH TO ENGR’S DTL ROOF CAPPING @ 1500mm C/C TO MFR’S DTL PVC CABLE IN FLEXIBLE CONDUIT MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1 mm THK TOP PANEL TO SO’S APPROVAL 3 PROPOSED 1 x 18W (IP 65) LIGHT FITTING 50 X 50 X 3 THK ALUM. ANGLE PLATE FOR BUS STOP ADDRESS & NUMBER SIGN PLATE BUS STOP ADDRESS & NUMBER SIGN PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION Qualified Person Endorsement : TYPICAL LIGHTING LAYOUT PLAN SCALE: NTS 1 2 3 7500 750 3000 3000 750 EARTH PIT (TOTAL RESISTANCE < 10ohm) ROOF EAVES ABOVE LTA Endorsement : 2 NOS. 50mm HEAVY DUTY UPVC PIPE C/W PULL WIRE NOTICE BOARD WITH ALUM. FRAME C/W 10mm THK. TEMPERED GLASS 600 REFUSE BIN A NEW OG BOX M.S. RHS POST @ 3000 mm C/C TO ENGR’S DTL ALUM. SEAT TO DTL 2 NOS. 100mm HEAVY DUTY UPVC HEAD-IN 90^ LONG BEND PIPES FOR POWERGRID’S INCOMING CABLE 3 1400 100 1 NO. 50mm HEAVY DUTY UPVC PIPE C/W PULL WIRES FROM 0G-BOX TO ADVERTISING PANEL 1400 1 NO. ELECT. PIPE FOR ADVERTISEMENT PANEL (AP) TO BE LOCATED AT THE DOWNSTREAM EDGE OF BUS SHELTER Project Title : STANDARD INSTALLATION DETAILS CONC. SLAB TO ENGR’S DTLS COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL 200 WIDE YELLOW LINE IN HOT APPLIED THERMOPLASTIC ROAD MARKING MATERIALS LINE OF ROAD KERB OR ROAD RESERVE LINE Drawing Title : TYPICAL LIGHTING LAYOUT PLAN AND LIGHTNING PROTECTION SYSTEM FOR BUS SHELTER (WITH OR WITHOUT RAILING) Designed NURLY ROAD Scale N.T.S. TYPICAL LIGHTNING PROTECTION SYSTEM LAYOUT PLAN $FILE$ Drawn JULI Approved MELVYN THONG Date JULY 2007 Rev. - L/ROAD/MES/SD/1007 Rev. $TIME$ MALVIN HO Drawing No. : SCALE: NTS $DATE$ Checked Date By Description Chk’d App’d CAD File Name : LROADMES-SD1007-.dgn Sheet 1 of 1 A4 A 1 2 3000 3 MIN. 600 300 2700 7500 750 3000 1500 3000 1500 750 1500 1500 MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1 mm THK TOP PANEL TO SO’S APPROVAL BUS STOP ADDRESS & NUMBER SIGN PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION (TO BE BOLTED TO ALUM. ANGLE PLATE) MS ANGLE ROOF FASCIA TO ENGR’S DTL PROPOSED 1 x 18W (IP65) LIGHT FITTING 3^ FALL LIGHT FITTING TO M&E SPECS & SHALL NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING M.S. RHS TO ENGR’S DETAIL 1000 PVC CABLE IN PVC FLEXIBLE CONDUIT M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C 1000 TO ENGR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. LIGHT FITTING TO M&E SPECS M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL NEW OG BOX (IP55) LOCATION SHALL BE SUBJECTED TO SITE CONDITIONS AND POWERGRID’S APPROVAL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL ELECTRICAL CABLE IN PVC FLEXIBLE PIPE IN SUPPORT POST CONC. SLAB TO ENGR’S DTL COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL NOTICE BOARD WITH ALUM. FRAME REFUSE BIN TO BE FIXED IN POSITION ALUM SEAT TO DETAIL C/W 10mm THK. TEMPERED GLASS ALUM. SEAT TO DTL 300 CONC. SLAB TO ENGR’S DTLS COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL CONDUIT ENCASED IN CONCRETE CABLE ENTRY ACCESS PANEL (REFER TO TYPICAL SUPPORT POST DETAIL) FFL FFL ROAD FOOTING TO ENGR’ S DETAIL 6m PVC EARTH BONDING CABLE IN 25mm HEAVY DUTY UPVC PIPE 2 NOS 50mm HEAVY DUTY UPVC PIPES ELEVATION 1 2 NOS 100mm HEAVY DUTY UPVC PIPES LEAD IN 90^ LONG BEND PIPES FOR POWERGRID INCOMING CABLING SECTION A-A CATCH BASIN AND UPVC PIPE IN (REFUSE BIN NOT SHOWN FOR CLARITY) Scale 1 :20 TYPICAL FRONT ELEVATION OF BUS SHELTER (WITHOUT RAILING) TYPICAL SECTION OF BUS SHELTER (WITHOUT RAILING) SCALE: NTS SCALE: NTS REF. DWG. NO. L/STLBS/AR/STD/0002 Qualified Person Endorsement : ACCORDANCE WITH THE CURRENT LTA STANDARD DETAILS OF ROAD ELEMENTS A 1 2 3000 3 300 MIN. 600 2700 7500 750 3000 1500 3000 1500 750 1500 1500 LTA Endorsement : MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1 mm THK TOP PANEL TO SO’S APPROVAL BUS STOP ADDRESS & NUMBER SIGN PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION (TO BE BOLTED TO ALUM. ANGLE PLATE) PROPOSED 1 x 18W (IP65) LIGHT FITTING MS ANGLE ROOF FASCIA TO ENGR’S DTL 3^ FALL LIGHT FITTING TO M&E SPECS & SHALL M.S. RHS TO ENGR’S DETAIL 1000 M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C 1000 NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING PVC CABLE IN PVC FLEXIBLE CONDUIT TO ENGR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. LIGHT FITTING TO M&E SPECS M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL NEW OG BOX (IP55) LOCATION SHALL BE SUBJECTED TO SITE CONDITIONS AND POWERGRID’S APPROVAL S/S RAILING TO BE PROVIDED WHERE THERE IS SUDDEN GREAT DIFFERENCE IN LEVEL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL ELECTRICAL CABLE IN PVC REFUSE BIN TO BE FIXED IN POSITION Project Title : FLEXIBLE PIPE IN SUPPORT POST CONC. SLAB TO ENGR’S DTL COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL NOTICE BOARD WITH ALUM. FRAME ALUM SEAT TO DETAIL C/W 10mm THK. TEMPERED GLASS BONDING TO ALUMINIUM SEAT ALUM. SEAT TO DTL STANDARD INSTALLATION DETAILS 300 CONDUIT ENCASED IN CONCRETE FFL FFL ROAD CABLE ENTRY ACCESS PANEL (REFER TO TYPICAL SUPPORT POST DETAIL) Drawing Title : FOOTING TO ENGR’ S DETAIL 6m PVC EARTH BONDING CABLE IN 25mm HEAVY DUTY UPVC PIPE 2 NOS 50mm HEAVY DUTY UPVC PIPES TYPICAL ELECTRICAL INSTALLATION DETAILS ELEVATION 1 2 NOS 100mm HEAVY DUTY UPVC PIPES LEAD IN 90^ LONG BEND PIPES FOR POWERGRID INCOMING CABLING SECTION A-A (REFUSE BIN NOT SHOWN FOR CLARITY) Scale 1 :20 REF. DWG. NO. L/STLBS/AR/STD/0004 FOR BUS SHELTER (WITH AND WITHOUT RAILING) CATCH BASIN AND UPVC PIPE IN ACCORDANCE WITH THE CURRENT LTA STANDARD DETAILS OF ROAD ELEMENTS TYPICAL FRONT ELEVATION OF BUS SHELTER (WITH RAILING) TYPICAL SECTION OF BUS SHELTER (WITH RAILING) SCALE: NTS SCALE: NTS Designed NURLY Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1008 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1008-.dgn Sheet 1 of 1 A4 A 3000 300 2700 1500 MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL ´ S/S SCREW CENTRE LINE OF LIGHT FITTING K S/S SCREW - C MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE - WITH MIN. 1mm THK.TOP PANEL TO SO’S APPROVAL 3^ FALL ISOLATOR / BONDING TAPE BETWEEN ALUM. ROOF FRAME & M.S. MEMBER 3%%d ISOLATOR / BONDING TAPE BETWEEN ALUM. ROOF FRAME & M.S. MEMBER 200 3%%d DETAIL 2 DETAIL 2 Scale 1:5 K - M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL C LIGHT FITTING TO M&E SPECS & SHALL NOT PROTRUDE FROM M.S. RAFTER / - CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL ELECTRICAL CABLE CONCEALED IN PVC FLEXIBLE CONDUIT IN SUPPORT POST ´ M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL ´ 50 mm PVC FLEXIBLE CONDUIT ELECTRICAL CABLE CONCEALED IN PVC FOR INCOMING CABLES TO M&E DETAIL FLEXIBLE CONDUIT TO M&E DWG. & SPEC. Qualified Person Endorsement : OPENING FOR INCOMING CABLES COVERED BY POST CAPPING (TO BE PROVIDED AT 1ST & LAST POST ONLY) M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL SECTION B-B G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. SECTION B-B DETAIL 1 1 DETAIL Scale 1:5 M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL Scale 1:5 M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL SECTION C-C TERMINAL BLOCK CONNECTOR MOUNTED ON TEAKWOOD BLOCK Y SECTION C-C PVC CABLE + 2.5m PVC EARTH CABLE IN FLEXIBLE CONDUIT LTA Endorsement : - Scale 1:5 TEAKWOOD FOR MOUNTING FLAT BAR TO SUPPORT TEAKWOOD BLOCK M8 ALUMINIUM COPPER BOLT TO STEEL SUPPORT POST OPENING FOR INCOMING CABLES COVERED SEE DETAIL X BY POST CAPPING (TO BE PROVIDED AT 1ST & LAST POST ONLY) B 750 1500 ALUMINIUM OR STEEL SUPPORT POST - 100 100 40 EARTH PIT (TOTAL EARTH RESISTANCE <10 ohms) 25mm x 3mm COPPER TAPE B 40 - CABLE GLAND FOR ARMOURED CABLE 10 FFL C1 WELDED ALL-ROUND TO 300x300x20 THK MS PLATE Y - SECTION Y-Y BUS STOP ADDRESS & NUMBER SIGN 10mm THK NON SHRINK GROUT PLATE TO FACE ONCOMING TRAFFIC IN ACCORDANCE TO LTA STD DRAWING NO. LTA/ARCH/CF/97/8/13 LATEST REVISION (TO BE BOLTED TO ALUM. ANGLE PLATE) ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL GASKET DETAIL X ´ ´ MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL Project Title : CONC. SLAB TO ENGR’S DTL COMPLETE WITH 25mm x 3mm COPPER TAPE 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL RC FOOTING TO ENGR’S DETAIL MS BASE PLATE TO ENGR’S DETAIL STANDARD INSTALLATION DETAILS TYPICAL SUPPORT POST DETAIL FROM OG BOX TO FIRST LIGHTING POINT Scale 1:5 ARMOURED CABLE IN UPVC PIPE M.S. ANGLE ROOF FASCIA ISOLATOR / BONDING TAPE BETWEEN TO ENGR’S DETAIL ALUM. ROOF FRAME & M.S. MEMBER MS RHS TO ENGR’S DETAIL LIGHT FITTING MOUNTING BRACKET TO CONTRACTOR PROPOSAL M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL TYPICAL SUPPORT POST DETAIL Drawing Title : LIGHT FITTING TO M&E SPECS & SHALL NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING SECTION K-K SECTION K-K TYPICAL CABLE ENTRY DETAIL FOR BUS SHELTER Scale 1:5 Designed NURLY Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - L/ROAD/MES/SD/1009 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1009-.dgn Sheet 1 of 1 A4 2800 2800 370 2060 370 370 EQ 2060 370 EQ EQ EQ MIN. 10mm THK. ALUM. HONEY COMB ROOF PANEL COMPLETE MIN. 10mm THK. ALUM. HONEY COMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL 12%%d 12%%d ´ OF POB DECK ´ OF POB DECK AND ROOF AND ROOF CHS HOT-DIPPED GALVANISED M.S. MEMBER CHS HOT-DIPPED GALVANISED M.S. MEMBER TO ENGR’S DETAIL COMPLETE WITH SPRAY COATING FINISH TO SO’S APPROVAL TO ENGR’S DETAIL COMPLETE WITH SPRAY COATING FINISH TO SO’S APPROVAL MIN. 40 TO ENGR’S DETAIL COMPLETE WITH SPRAY COATING FINISH TO SO’S APPROVAL PURPOSE MADE BOND CONTRACTOR TO ENSURE THAT BONDED IN ACCORDANCE TO CP33 REQUIREMENTS CHS HOT-DIPPED GALVANISED M.S. POST PURPOSE MADE BOND CONTRACTOR TO ENSURE THAT BONDED IN ACCORDANCE TO CP33 REQUIREMENTS CHS HOT-DIPPED GALVANISED M.S. POST TO ENGR’S DETAIL COMPLETE WITH SPRAY COATING FINISH TO SO’S APPROVAL MIN. 40 MIN. 40 MIN. 40 1800 1800 45mm S.S. RAILING 15mm S.S. ROD AT NOT MORE THAN 100mm CLEAR 15mm S.S. ROD AT NOT MORE THAN 100mm CLEAR BI-METALLIC BOND/CLAMP AND ALUMINIUM CONDUCTOR TAPE BOLTED ON BEARING PLATE CONCRETE SURFACE PAINTED OVER TO PREVENT ALUMINIUM TAPE TO HAVE DIRECT CONTACT WITH CONCRETE SURFACE (SEE DETAIL X) 2200 675 FFL OF POB DECK BI-METALLIC BOND/CLAMP AND ALUMINIUM CONDUCTOR TAPE BOLTED ON BEARING PLATE. CONCRETE SURFACE PAINTED OVER TO PREVENT ALUMINIUM TAPE TO HAVE DIRECT CONTACT WITH CONCRETE SURFACE 45mm S.S. RAILING BI-METALLIC BOND/CLAMP AND ALUMINIUM CONDUCTOR TAPE BOLTED ON BEARING PLATE CONCRETE SURFACE PAINTED OVER TO PREVENT ALUMINIUM TAPE TO HAVE DIRECT CONTACT WITH CONCRETE SURFACE (SEE DETAIL X) 675 700 FFL OF POB DECK TYPICAL CROSS BEAM FALL FALL 2200 TO ENGR’S DETAIL UPVC PIPE SEALED WITH APPROVED SEALANT TO PREVENT WATER INGRESS 700 TYPICAL CROSS BEAM FALL FALL TO ENGR’S DETAIL DETAIL X 75 75 PLANTING TROUGH WITH WATERPROOFING PLANTING TROUGH WITH WATERPROOFING MEMBRANE TO SO’S APPROVAL MEMBRANE TO SO’S APPROVAL PIPE SLEEVE PIPE SLEEVE 20mm THK PRECASTED GRANOLITHIC 20mm THK PRECASTED GRANOLITHIC CHIPPING FINISHED TO S.O’S APPROVAL CHIPPING FINISHED TO S.O’S APPROVAL 625 625 Y - 10x10mm CHAMFER 10x10mm CHAMFER 25mm x 3mm ALUMINIUM TAPE RC COLUMN TO ENGR’S DETAIL WITH RC COLUMN TO ENGR’S DETAIL WITH 20mm THK PRECASTED GRANOLITHIC CHIPPING FINISHED TO S.O’S APPROVAL 20mm THK PRECASTED GRANOLITHIC CHIPPING FINISHED TO S.O’S APPROVAL Qualified Person Endorsement : M5 COUNTERSUNK BOLT NUT INSERT LIGHTNING PROTECTION BI-METALLIC CONNECTOR TEST BOX 25mm x 3mm COPPER TAPE STAINLESS STEEL COVER PLATE LTA Endorsement : Y - 25mm x 3mm ALUMINIUM CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE ELEVATION VIEW (WITH COVER) ELEVATION VIEW (WITHOUT COVER) 25mm x 3mm ALUMINIUM CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE 150mm x 150mm TEST LINK BOX AT 1500mm HEIGHT FROM GROUND LEVEL (SURFACE MOUNT) IN ACCORDANCE TO CP33 REQUIREMENTS (SEE TYPICAL LIGHTNING PROTECTION TEST BOX AT POB) 150mm x 150mm TEST LINK BOX AT 1500mm HEIGHT FROM GROUND LEVEL (SURFACE MOUNT) IN ACCORDANCE TO CP33 REQUIREMENTS (SEE TYPICAL LIGHTNING PROTECTION TEST BOX AT POB) ENCASED HEAVY DUTY UPVC PIPES 25mm x 3mm ALUMINIUM TAPE STAINLESS STEEL COVER PLATE BI-METALLIC CONNECTOR Project Title : 25mm x 3mm COPPER TAPE R.C. COLUMN ENCASED HEAVY DUTY UPVC PIPES 25mm x 3mm COPPER CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE STANDARD INSTALLATION DETAILS 50mm PVC PIPE FOR LIGHTING CIRCUITS TO OG BOX TO M&E SPECIFICATIONS 25mm x 3mm COPPER CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE SECTION Y-Y EARTH PIT (TOTAL EARTH RESISTANCE 10ohms) R.C. GRATING FOOTPATH LEVEL R.C. GRATING EARTH PIT (TOTAL EARTH RESISTANCE 10ohms) FOOTPATH LEVEL ROAD LEVEL Drawing Title : TYPICAL LIGHTNING PROTECTION TEST BOX AT POB TO ROADSIDE DRAIN EARTH ROD ROAD LEVEL TYPICAL LIGHTNING PROTECTION SYSTEM TO ROADSIDE DRAIN EARTH ROD FOR COVERED PEDESTRIAN OVERHEAD BRIDGE PILE CAP TO ENGR’S DETAIL Designed NURLY PILE CAP TO ENGR’S DETAIL FOR COVERED POB (NON-EXPRESSWAY) Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : FOR COVERED POB (EXPRESSWAY) Rev. - L/ROAD/MES/SD/1010 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1010-.dgn Sheet 1 of 1 A4 LOCATION OF SUPPORT POST FOR FUTURE COVER MIN. 40 LOCATION OF SUPPORT POST FOR FUTURE COVER MIN. 40 MIN. 40 MIN. 40 1800 1800 45mm S.S. RAILING BI-METALLIC BOND/CLAMP AND ALUMINIUM CONDUCTOR TAPE BOLTED ON BEARING PLATE. CONCRETE SURFACE PAINTED OVER TO PREVENT ALUMINIUM TAPE TO HAVE DIRECT CONTACT WITH CONCRETE SURFACE 45mm S.S. RAILING 15mm S.S. ROD AT NOT MORE THAN 100mm CLEAR S.S. LIGHTING ENCASEMENT TO DETAIL LIGHT FITTING TO M&E SPEC. & SO’S APPROVAL 25mm x 3mm ALUMINIUM CONDUCTOR TAPE 2200 675 FFL OF POB DECK BI-METALLIC BOND/CLAMP AND ALUMINIUM CONDUCTOR TAPE BOLTED ON BEARING PLATE CONCRETE SURFACE PAINTED OVER TO PREVENT ALUMINIUM TAPE TO HAVE DIRECT CONTACT WITH CONCRETE SURFACE (SEE DETAIL X) 25mm x 3mm ALUMINIUM CONDUCTOR TAPE 700 675 FALL 2200 FFL OF POB DECK TYPICAL CROSS BEAM FALL BI-METALLIC BOND/CLAMP AND ALUMINIUM CONDUCTOR TAPE BOLTED ON BEARING PLATE CONCRETE SURFACE PAINTED OVER TO PREVENT ALUMINIUM TAPE TO HAVE DIRECT CONTACT WITH CONCRETE SURFACE (SEE DETAIL X) S.S. LIGHTING ENCASEMENT TO DETAIL TO ENGR’S DETAIL UPVC PIPE SEALED WITH APPROVED SEALANT TO PREVENT WATER INGRESS 700 TYPICAL CROSS BEAM FALL FALL TO ENGR’S DETAIL DETAIL X 75 75 PLANTING TROUGH WITH WATERPROOFING PLANTING TROUGH WITH WATERPROOFING MEMBRANE TO SO’S APPROVAL PIPE SLEEVE MEMBRANE TO SO’S APPROVAL PIPE SLEEVE 100mm PVC PIPE WITH 5mm HOLES 100mm PVC PIPE WITH 5mm HOLES PERFORATION AT 100mm C/C ALL DIRECTIONS PERFORATION AT 100mm C/C ALL DIRECTIONS 20mm THK PRECASTED GRANOLITHIC 20mm THK PRECASTED GRANOLITHIC CHIPPING FINISHED TO S.O’S APPROVAL CHIPPING FINISHED TO S.O’S APPROVAL 625 Y - 625 25mm x 3mm ALUMINIUM TAPE RC COLUMN TO ENGR’S DETAIL WITH RC COLUMN TO ENGR’S DETAIL WITH 20mm THK PRECASTED GRANOLITHIC CHIPPING FINISHED TO S.O’S APPROVAL 20mm THK PRECASTED GRANOLITHIC CHIPPING FINISHED TO S.O’S APPROVAL M5 COUNTERSUNK BOLT NUT INSERT Qualified Person Endorsement : LIGHTNING PROTECTION BI-METALLIC CONNECTOR TEST BOX 25mm x 3mm COPPER TAPE STAINLESS STEEL COVER PLATE Y LTA Endorsement : - ELEVATION VIEW (WITH COVER) ELEVATION VIEW (WITHOUT COVER) 25mm x 3mm ALUMINIUM CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE 25mm x 3mm ALUMINIUM CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE ENCASED HEAVY DUTY UPVC PIPES 150mm x 150mm TEST LINK BOX AT 1500mm HEIGHT FROM GROUND LEVEL (SURFACE MOUNT) IN ACCORDANCE TO CP33 REQUIREMENTS (SEE TYPICAL LIGHTNING PROTECTION TEST BOX AT POB) 150mm x 150mm TEST LINK BOX AT 1500mm HEIGHT FROM GROUND LEVEL (SURFACE MOUNT) IN ACCORDANCE TO CP33 REQUIREMENTS (SEE TYPICAL LIGHTNING PROTECTION TEST BOX AT POB) 25mm x 3mm ALUMINIUM TAPE STAINLESS STEEL COVER PLATE BI-METALLIC CONNECTOR Project Title : 25mm x 3mm COPPER TAPE R.C. COLUMN ENCASED HEAVY DUTY UPVC PIPES 25mm x 3mm COPPER CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE STANDARD INSTALLATION DETAILS SECTION Y-Y 25mm x 3mm COPPER CONDUCTOR TAPE ENCASED IN 50mm HEAVY DUTY UPVC PIPE EARTH PIT (TOTAL EARTH RESISTANCE 10ohms) R.C. GRATING FOOTPATH LEVEL R.C. GRATING EARTH PIT (TOTAL EARTH RESISTANCE 10ohms) FOOTPATH LEVEL TYPICAL LIGHTNING PROTECTION TEST BOX AT POB ROAD LEVEL TO ROADSIDE DRAIN EARTH ROD Drawing Title : ROAD LEVEL TYPICAL LIGHTNING PROTECTION SYSTEM TO ROADSIDE DRAIN EARTH ROD FOR UNCOVERED PEDESTRIAN OVERHEAD BRIDGE PILE CAP TO ENGR’S DETAIL Designed NURLY PILE CAP TO ENGR’S DETAIL FOR UNCOVERED POB (NON-EXPRESSWAY) Scale N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : FOR UNCOVERED POB (EXPRESSWAY) Rev. - L/ROAD/MES/SD/1011 Rev. $DATE$ $TIME$ $FILE$ Date By Description Chk’d App’d CAD File Name : LROADMES-SD1011-.dgn Sheet 1 of 1 A4 750 ¨81 ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL ELECTRICAL CABLE CONCEALED IN PVC FLEXIBLE CONDUIT TO M&E DWG. & SPEC. M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA ALUM FLASHING PIECE BOLTED AT BOTH END FOR ELECT. CABLES TO M&E DWG. & SPEC. LIGHT FITTING TO M&E SPEC & SHALL NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING 50 x 50 x 3 ALUM ANGLE PLATE M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL LIGHT FITTING TO M&E SPEC & SHALL NOT PROTRUDE FROM M.S. RAFTER / CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING ELECTRICAL CABLE CONCEALED IN PVC FLEXIBLE CONDUIT IN SUPPORT POST M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL 750 SECTION C-C SECTION C-C Scale 1:5 ´ M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL ´ 50 mm PVC FLEXIBLE CONDUIT FOR INCOMING CABLES TO M&E DETAIL LIGHT FITTING TO M&E SPEC OPENING FOR INCOMING CABLES COVERED (DESIGN TO REFER TO ARCH DWG) BY POST CAPPING (TO BE PROVIDED AT 1ST & LAST POST ONLY) SECTION B-B Scale 1:5 SECTION B-B SECTION J-J TYPICAL LONGITUDINAL CROSS SECTION AT ROOF WITH LEVEL DIFFERENCE TYPICAL LONGITUDINAL CROSS SECTION AT ROOF WITH LEVEL DIFFERENCE Qualified Person Endorsement : Scale 1:5 REF. DWG. NO. L/STLLW/AR/STD/1002 A MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL 300 S/S SCREW S/S SCREW MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE C WITH MIN. 1mm THK.TOP PANEL TO SO’S APPROVAL - 3^ FALL ISOLATOR / BONDING TAPE BETWEEN ALUM. ROOF FRAME & M.S. MEMBER ISOLATOR / BONDING TAPE BETWEEN ALUM. ROOF FRAME & M.S. MEMBER Y - LTA Endorsement : DETAIL 2 Scale 1:5 M8 ALUMINIUM COPPER BOLT TO STEEL SUPPORT POST 25mm x 3mm COPPER TAPE LIGHT FITTING TO M&E SPEC & SHALL NOT PROTRUDE FROM M.S. RAFTER / C CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING - ALUMINIUM OR STEEL SUPPORT POST G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. ELECTRICAL CABLE CONCEALED IN PVC FLEXIBLE CONDUIT IN SUPPORT POST Y - M.S. RHS POST @ 3000 mm C/C TO ENGR’S DETAIL SECTION Y-Y M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL 750 DETAIL X 1500 DETAIL 1 DETAIL 1 ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL Scale 1:5 Project Title : GASKET ´ ´ M.S. ANGLE ROOF FASCIA PVC CABLE + 2.5m PVC EARTH CABLE IN FLEXIBLE CONDUIT MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL TO ENGR’S DETAIL TERMINAL BLOCK CONNECTOR MOUNTED ON TEAKWOOD BLOCK STANDARD INSTALLATION DETAILS TEAKWOOD FOR MOUNTING OPENING FOR INCOMING CABLES COVERED SEE DETAIL X BY POST CAPPING (TO BE PROVIDED AT 1ST & LAST POST ONLY) B B 40 - FLAT BAR TO SUPPORT TEAKWOOD BLOCK CABLE GLAND FOR ARMOURED CABLE EARTH PIT (TOTAL EARTH RESISTANCE <10 ohms) 100 ISOLATOR / BONDING TAPE BETWEEN M.S. ANGLE ROOF FASCIA ALUM. ROOF FRAME & M.S. MEMBER TO ENGR’S DETAIL 100 MS RHS TO ENGR’S DETAIL FFL C1 WELDED ALL-ROUND TO 300x300x20 THK MS PLATE Drawing Title : LIGHT FITTING MOUNTING BRACKET TO CONTRACTOR PROPOSAL M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL TYPICAL CABLE ENTRY DETAIL LIGHT FITTING TO M&E SPEC. & SHALL NOT PROTRUDE FROM M.S. RAFTER / 10mm THK NON SHRINK GROUT FOR SINGLE POST COVERED LINKWAY CONTRACTOR TO PROPOSE FIXING BRACKET FOR LIGHT FITTING SECTION K-K SECTION K-K Scale 1:5 Designed REF. DWG. NO. L/STLLW/AR/STD/1002 CONC. SLAB TO ENGR’S DTL COMPLETE WITH 25mm x 3mm COPPER TAPE Checked Approved 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL NURLY MALVIN HO MELVYN THONG RC FOOTING TO ENGR’S DETAIL Scale MS BASE PLATE TO ENGR’S DETAIL TYPICAL SUPPORT POST DETAIL ARMOURED CABLE IN UPVC PIPE N.T.S. Drawn JULI Date JULY 2007 FROM OG BOX TO FIRST LIGHTING POINT Scale 1:5 Drawing No. : TYPICAL CROSS SECTION FOR SINGLE POST COVERED LINKWAY $TIME$ $FILE$ - L/ROAD/MES/SD/1012 Rev. $DATE$ Rev. Date By Description Chk’d App’d CAD File Name : LROADMES-SD1012-.dgn Sheet 1 of 1 A4 750 ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL ¨81 MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL ELECTRICAL CABLE CONCEALED IN PVC FLEXIBLE CONDUIT TO M&E DWG. & SPEC. M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. ALUM FLASHING PIECE BOLTED AT BOTH END LIGHT FITTING TO M&E SPEC. / CONTRACTOR TO M.S. ’C’ CHANNEL RAFTER TO ENGR’S DETAIL PROPOSE MOUNTING BRACKET FOR LIGHT FITTING M.S. SUPPORT POST @ 3000 mm C/C TO ENGR’S DETAIL 50 X 50 X 3 ALUM ANGLE PLATE M.S. SUPPORT POST @ 3000 mm C/C TO ENGR’S DETAIL MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL SECTION C-C SECTION C-C Scale 1:5 ALUM. ROOF CAPPING FOR ROOF PANEL ELECTRICAL CABLE CONCEALED IN PVC TO MFR’S DETAIL FLEXIBLE CONDUIT IN SUPPORT POST 750 1500 750 ALUM. ROOF CAPPING FOR ROOF PANEL TO MFR’S DETAIL GASKET ´ ´ M.S. ANGLE ROOF FASCIA MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL TO ENGR’S DETAIL 40 ISOLATOR / BONDING TAPE BETWEEN ALUM. ROOF FRAME & M.S. MEMBER LIGHT FITTING TO M&E SPEC (DESIGN TO REFER TO ARCH DWG) M.S. RHS TO ENGR’S DETAIL M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL 100 LIGHT FITTING MOUNTING BRACKET TO CONTRACTOR PROPOSAL LIGHT FITTING TO M&E SPEC. / CONTRACTOR TO PROPOSE MOUNTING BRACKET FOR LIGHT FITTING SECTION E-E M.S. SUPPORT POST @ 3000 mm C/C TO ENGR’S DETAIL TYPICAL LONGITUDINAL CROSS SECTION AT ROOF WITH LEVEL DIFFERENCE SECTION D-D TYPICAL LONGITUDINAL CROSS SECTION AT ROOF WITH LEVEL DIFFERENCE Scale 1:5 SECTION D-D Scale 1:5 REF. DWG. NO. L/STLLW/AR/STD/2002 Qualified Person Endorsement : Y A - B 2400 300 1800 300 1200 M8 ALUMINIUM COPPER BOLT TO STEEL SUPPORT POST 25mm x 3mm COPPER TAPE MIN. 10mm THK. ALUM. HONEYCOMB ROOF PANEL COMPLETE ALUMINIUM OR STEEL SUPPORT POST WITH MIN. 1mm THK.TOP PANEL TO SO’S APPROVAL C LTA Endorsement : 3^ FALL ISOLATOR / BONDING TAPE BETWEEN - ALUM. ROOF FRAME & M.S. MEMBER S/S SCREW Y - SECTION Y-Y DETAIL X M.S. ANGLE ROOF FASCIA TO ENGR’S DETAIL LIGHT FITTING TO M&E SPEC. / CONTRACTOR TO PROPOSE MOUNTING BRACKET FOR LIGHT FITTING 80 CENTRE OF LIGHT FITTING C ´ - PVC FLEXIBLE CONDUIT FOR M.S. ’C’ CHANNEL RAFTER @ 3000 mm C/C TO ENGR’S DETAIL INCOMING CABLES TO M&E DETAIL ELECTRICAL CABLE CONCEALED IN PVC M.S. SUPPORT POST @ 3000 mm C/C FLEXIBLE CONDUIT IN SUPPORT POST TO ENGR’S DETAIL ´ G.I. PIPE ALONG BACK OF M.S. FASCIA FOR ELECT. CABLES TO M&E DWG. & SPEC. 1720 BOTTOM OPENING FOR INCOMING CABLES Project Title : COVERED BY POST CAPPING (TO BE PROVIDED AT 1ST & LAST POST) M.S. SUPPORT POST @ 3000 mm C/C TO ENGR’S DETAIL SECTION B-B SECTION B-B Scale 1:5 PVC CABLE + 2.5m PVC EARTH CABLE IN FLEXIBLE CONDUIT STANDARD INSTALLATION DETAILS TERMINAL BLOCK CONNECTOR MOUNTED ON TEAKWOOD BLOCK TEAKWOOD FOR MOUNTING SEE DETAIL X B B - - Drawing Title : FLAT BAR TO SUPPORT TEAKWOOD BLOCK 100 40 100 CABLE GLAND FOR ARMOURED CABLE EARTH PIT (TOTAL EARTH RESISTANCE <10 ohms) OPENING FOR INCOMING CABLES COVERED FFL TYPICAL CABLE ENTRY DETAIL FFL BY POST CAPPING (TO BE PROVIDED AT 1ST & LAST POST ONLY) C1 WELDED ALL-ROUND TO 300x300x20 THK MS PLATE FOR DOUBLE POST COVERED LINKWAY CONC. SLAB TO ENGR’S DTL COMPLETE WITH 20mm THK GRANOLITHIC FINISHES TO SO’S APPROVAL 10mm THK NON SHRINK GROUT Designed M.S. BASE PLATE TO ENGR’S DETAIL NURLY RC FOOTING TO ENGR’S DETAIL 25mm x 3mm COPPER TAPE TYPICAL CROSS SECTION Scale Scale 1:5 N.T.S. Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 ARMOURED CABLE IN UPVC PIPE Drawing No. : FROM OG BOX TO FIRST LIGHTING POINT TYPICAL CROSS SECTION FOR DOUBLE POST COVERED LINKWAY $DATE$ $TIME$ $FILE$ Rev. - L/ROAD/MES/SD/1013 Rev. Date By Description Chk’d App’d CAD File Name : LROADMES-SD1013-.dgn Sheet 1 of 1 A4 1 2 3 5 4 6 7 8 9 750 750 750 3000 3000 3000 3000 3000 10 3000 3000 750 BONDING DETAILS TO ROOF SPECIALIST’S REQUIREMENTS 750 ¨81 750 ¨81 BONDING TO UPPER ROOF LIGHTNING PROTECTION SYSTEM (BONDING DETAILS TO ROOF SPECIALIST’S REQUIREMENTS) ALUM FLASHING PIECE J MS ANGLE ROOF FASCIA TO ENGR’S DETAIL L/STLLW/AR/STD/1006 BONDING DETAILS TO ROOF SPECIALIST’S REQUIREMENTS SUPPORT POST TO ENGR’S DETAIL 200 MS ANGLE ROOF FASCIA TO ENGR’S DETAIL BONDING TO UPPER ROOF LIGHTNING PROTECTION SYSTEM (BONDING DETAILS TO ROOF SPECIALIST’S REQUIREMENTS) 820 (CLEAR) FFL SUPPORT POST TO ENGR’S DETAIL EARTH PIT OG BOX FFL FFL SUPPORT POST TO ENGR’S DETAIL FRONT ELEVATION WITH LEVEL DIFFERENCE OG BOX ON CONC. PLINTH TO M&E DTLS FRONT ELEVATION OF LIGHTNING PROTECTION LAYOUT PLAN (LOCATION TO BE DETERMINED ON SITE & TO POWERGRID’S APPROVAL) Scale 1:50 1 2 750 3 3000 4 3000 5 3000 6 3000 7 3000 3000 750 ROOF CAPPING TO MFR’S DETAIL MS ANGLE ROOF FASCIA TO 200 BONDING DETAILS TO ROOF SPECIALIST’S REQUIREMENTS ENGR’S DETAIL 820 (CLEAR) SUPPORT POST TO ENGR’S DETAIL OG BOX FFL Qualified Person Endorsement : EARTH PIT OG BOX ON CONC. PLINTH TO M&E DTLS (LOCATION TO BE DETERMINED ON SITE & TO POWERGRID’S APPROVAL) FRONT ELEVATION 1 (WITHOUT LEVEL DIFFERENCE) FRONT ELEVATION OF OG BOX POSITION Scale 1:50 1 2 750 3 3000 1500 4 3000 1500 1500 5 3000 1500 1500 6 3000 1500 1500 7 3000 1500 1500 3000 1500 750 1500 1500 LTA Endorsement : (LOCATION TO BE DETERMINED ON SITE & TO RO APPROVAL) SUPPORT POST TO ENGR’S DETAIL A K K L/STLLW/AR/STD/1006 ROOF CAPPING TO MFR’S DETAIL MS ANGLE ROOF FASCIA TO ENGR’S DETAIL ROOF CAPPING TO MFR’S DETAIL MS ANGLE ROOF FASCIA TO ENGR’S DETAIL 1 MIN. 10mm THK. ALUM. HONEY COMB ROOF PANEL - COMPLETE WITH MIN. 1mm THK. TOP PANEL TO SO’S APPROVAL ROOF PLAN OF LINKWAY (WITHOUT LEVEL DIFFERENCE) LIGHTNING PROTECTION LAYOUT PLAN Project Title : Scale 1:50 1 2 750 3 3000 3000 4 5 3000 3000 1500 6 STANDARD INSTALLATION DETAILS 7 3000 3000 750 1500 OG BOX ON CONC. PLINTH TO M&E DTLS 200 820 (CLEAR) A (LOCATION TO BE DETERMINED ON SITE & TO POWERGRID’S APPROVAL) ROOF EAVES ABOVE Drawing Title : OG BOX SUPPORT POST TO ENGR’S DETAIL 2 NOS. 100mm HEAVY DUTY UPVC PIPE TYPICAL OG BOX POSITION FOR COVERED LINKWAY EXPANSION JOINT AT REGULAR INTERVAL EMBEDED UNDER GROUND FOR POWERGRID INCOMING CABLES TO M&E SPEC. & APPROVAL (LOCATION & ORIENTATION TO BE DETERMINED ON SITE) ALONG CENTRE OF GRID TO ENGR’S DETAIL CONC. SLAB TO ENGR’S DTLS COMPLETE WITH 20mm THK. GRANOLITHIC FINISHES TO SO’S APPROVAL Designed NURLY Scale LINE OF ROAD KERB N.T.S. ROAD 1 Checked MALVIN HO Drawn JULI Approved MELVYN THONG Date JULY 2007 Drawing No. : Rev. - Rev. $DATE$ $TIME$ $FILE$ - L/ROAD/MES/SD/1014 LAYOUT PLAN OF LINKWAY (WITHOUT LEVEL DIFFERENCE) OG BOX POSITION LAYOUT PLAN Date By Description Chk’d App’d CAD File Name : LROADMES-SD1014-.dgn Sheet 1 of 1 A4