CI/SfB (35)Xy 11/2015 metal leaflet Hook-On b-h 300 system 02 f-h 600 system 09 k-h 400 system 16 r-h 200 system 23 r-h 215 system 30 D-H 700 system 37 Metal product CI/SfB (35)Xy 11/2015 b-h 300 system Linear grid :::: 4 B-H 300 SYSTEM Linear grid Specification System Armstrong ceiling system B-H 300, Hook-On solution with visible grid, with optional swing-down "Window» function, suspension height min. 100 mm Panel Material galvanised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or further materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* rectangular panel square edged long sides CA / DA (30 - 55 mm) short sides E1 / F1 (30 mm) Gap solution 3 mm gap, with black gasket one long and short side Service integration standard round or rectangular cut-outs plus customised options on request Special capabilities - trapezoidal panel solution - curved panel solution - chilled ceiling solution - can be combined with other Armstrong products Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Configurable dimensions panel length (A) 600 - 3000 mm panel width (B) 275 - 1350 mm Grid system U-profile + C-profile 100 mm Further suspension methods on request Perimeter solution Range of standards trims in steel and aluminium plus custom bulkheads available * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns BENEFITS n C ombining functionality with stylish simplicity n C reates a linear visual effect n C -profiles alignment with partitions to help fixing/support for partitions. n R emarkably versatile n Various design options for the profile and panel (linear, radial, crossed) n Easy access to the ceiling void APPLICATION AREA n Used in large office environments and flexible with partitioning systems... Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Project: Palazzo Uffici, Milano (IT) :::::::: Architect: Genius Loci Architettura s.r.l Other perforation patterns available on request. Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 5 :::: :::: 6 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance in terms of sound absorption, sound attenuation and sound reduction. These performance values will depend upon the perforation and the acoustic infill. Please contact us for more information on the available factory fitted acoustic options. Standard colours Cross-section RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss expansion bolt M6 ceiling void threaded rod M6 hanger for Bandraster profile Thermal Conductivity wall anchor RAL 9010 Global White RAL 9006 clamping bracket U-profile RAL 9007 Special colours Other RAL and NCS colours available on request rectangular panel system B-H 300 ~68 98 (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece plug-in clip Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specifications of requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. C-profile perimeter trim visible side max. M/2 Longitudinal-section Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Environmental expansion bolt M6 Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). threaded rod M6 ceiling void clamping bracket U-profile rectangular panel system B-H 300 Acoustics Safe & Healthy % perimeter trim ISO 14021 Light reflectance (%) up to aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified Premium OP19 up to 30 up to 30 visible side max. M/2 Recycled content (%) Premium B15 ~68 98 Bandraster profile Sustainability depends on perforation depends on perforation 0.65 1.00 C A Humidity Fire reaction Resistance (%) up to Bioguard Cleanability paint option 10 A2-s2, d0 95 wipeable moist cloth (3) 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ 0.10 44 19 A1 95 scrubbable 0.60 0.90 41 31 20 15 A2-s1, d0 A2-s2, d0 95 95 Scratch resistance M = module size / A = panel length / B = panel width ✔ ✔ wipeable moist cloth wipeable moist cloth (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ ✔ ✔ ✔ Item No. Designation Item No. BPM 311067 Designation BPM 300100 U-profile BPM 300119 connector for U-profile BPM 300120 plug-in clip BPM 300144 wall anchor for C-profile BPM 300140 wall anchor BPM 311205 partition holder for C-profile BPM 300121 clamping bracket BPM 311303 hexagonal bolt M6 x 16 mm BPM 311111 expansion bolt M6 x 30 mm BPM 311103 hexagonal nut M6 BPM 311099 threaded rod M6 x 1‘000 mm BPM 311305 washer M6 18 x 1.6 mm BPM 215500 C-profile 100 mm BPM 300118G connector for C-profile hanger for C-profile 7 :::: Detail A B-H 300 panel hexagonal bolt M6 hexagonal nut M6 washer M6 Detail B grid system For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet Fall 1 Fall A wall anchor for C-profile expansion bolt M6 threaded rod M6 clamping bracket plug-in clip wall anchor Fall A Fall 1 hanger for C-rofile connector for U-profile connector for C-profile U-profile wall anchor for C-profile used as cross-connector partition holder for C-profile C-profile Project: Palazzo Uffici, Milano (IT) :::::::: Architect: Genius Loci Architettura s.r.l Detail C suspension methods optional B-H 300 Easy panel with hinge-down function optional B-H 300 Swing panel with swing-down function clamping bracket with threaded rod U-profile hanger with threaded rod combi Nonius hanger with Nonius to part combi Nonius hanger with eye wire Metal product CI/SfB (35)Xy 11/2015 f-h 600 system Corridor ceiling :::: 11 F-H 600 System Corridor ceilings Specification System F-H 600 System Armstrong ceiling system F-H 600, Hook-On solution with concealed grid, installation height min. 170 mm for wall bracket at perimeter with 5 - 65 mm shadow gap between wall and panel F-H 600 Swing Function Armstrong ceiling system F-H 600 Swingdown, Hook-On solution with visible grid, installation height min. 155 mm for wall bracket at perimeter with 0 - 72 mm shadow gap between wall and profile with integrated swing-down function Panel material Galvinised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or other materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* F-H 600 System Rectangular panel square edged Long sides CA / DA (30 - 55 mm) Short sides E4 / F4A (30 mm) with standard notching F-H 600 Swing Function Rectangular panel square edged Long sides CA / DA (45 - 55 mm) Short sides E2 / F2 (40 mm) with standard notching Gap solution F-H 600 System 0 mm gap on long side, without gasket Variable shadowgap on short side to cover wall tolerances F-H 600 Swing Function 3 mm gap, with black gasket on one long and two short sides Configurable dimensions F-H 600 System Panel length 600 - 3000 mm Panel width 275 - 1350 mm F-H 600 Swing Function Panel length 600 - 3000 mm Panel width 247 - 750 mm Grid system F-H 600 System Wall bracket attached to the wall in combination with J-bar, optional perimeter trim to cover the gap F-H 600 Swing Function Wall bracket attached to the wall in combination with G-profile Service integration Standard round or rectangular cut-outs according to customer needs *F or further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. standard perforation patterns BENEFITS n Free-span solution n Rectangular panel, adapted to corridor or circulation area width n Meets visual and individual project requirements n Easy, quick access to ceiling void due to the swing-down function n Perimeter trim is not part of the standard solution. It’s available as an option APPLICATION AREA n Corridors where the panels simply span between walls. Project: Terna, Roma (IT) :::::::: Architect: Gabriele Napolitano, S&PA Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Open area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Other perforation patterns available on request. Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 12 :::: :::: 13 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance in terms of sound absorption, sound attenuation and sound reduction. These performance values will depend upon the perforation and the acoustic infill. Please contact us for more information on the available factory fitted acoustic options. Standard colours CROSS-SECTION - F-H 600 RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Installations Thermal Conductivity Wall bracket RAL 9010 Global White RAL 9006 F-H 600 rectangular panel RAL 9007 Special colours Other RAL and NCS colours available on request Humidity Exposure Visible side Up to 95% RH (for short term exposure). 5 - 65 Quality Standard Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specifications or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Sustainability *Wall bracket can be swept and installed without perimeter trim, for a gap of 0 - 90 mm Longitudinal-section Environmental Our metal panels have an average of up to 30% recycled content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Acoustics Ceiling void Wall bracket Perimeter trim option to cover gap Safe & Healthy % Microperforation Rd 1522 (2) Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity resistance (%) up to Cleanability up to up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 Bioguard paint option Scratch resistance ✔ ✔ wipeable moist cloth (3) Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Item No. BPM 311007 ✔ ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ J-bar 5 - 65 Perimeter trim option to cover gap* F-H 600 rectangular panel Extra Microperforation Rg 0701 (2) Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Ceiling void (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece Designation Wall bracket BPM 300026 J-bar BPM 300343 Connector for J-bar BPM 311303 Hexagonal bolt M6 x 16 mm BPM 311103 Hexagonal nut M6 BPM 311305 Washer M6 18 x 1.6 mm J-bar Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Visible side 14 :::: :::: 15 F-H 600 System F-H 600 Swing Function Detail A F-H 600 rectangular panel Detail B Grid system Detail A F-H 600 rectangular panel Detail B Grid system Fall 2 Wall bracket Fall 4A Fall A Fall A Wall bracket Fall A Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Fall A Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Fall 2 Fall 4 Connector for J-bar J-bar G-profile Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Swing-down function Item No. Wall bracket Designation BPM 311007 Wall bracket BPM 300171 G-profile BPM 311303 Hexagonal bolt M6 x 16 mm BPM 311103 Hexagonal nut M6 BPM 311305 Washer M6 18 x 1.6 mm For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet F-H 600 Swing rectangular panel G-profile Metal product CI/SfB (35)Xy 11/2015 k-h 400 system Tartan grid :::: 18 K-H 400 SYSTEM Tartan grid Specification System Armstrong ceiling system K-H 400, Hook-On solution with visible grid, with optional hinge-down “Easy” function with optional swing-down “Swing” function suspension height min. 85 mm Panel material galvanised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or other materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* rectangular panel square edged long sides CA / DA (30 - 55 mm) short sides E1 / F1 (30 mm) Gap solution 3 mm gap, with black gasket on long and short side Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Configurable dimensions panel length (A) 600 - 2850 mm panel width (B) 275 - 1350 mm (panel width for Swing option 247 - 750 mm) Grid system crossing-box 100 x 100 mm with customised C-profile 100 mm width Perimeter solution range of standards trims in steel and aluminium plus custom bulkheads available Service integration standard round or rectangular cut-outs plus customised options on request. Special capabilities - triangular panel solution - truncated pyramid solution - chilled ceiling solution - can be combined with other Armstrong products * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns BENEFITS n Solution for square and/or rectangular room partitioning n Easily installed and removed n Grid can be emphasised by using contrasting colours n C-profiles can connect to the partition systems to integrate lighting systems efficiently n Decorative solutions achieved through a variety of panel design options (square mega panel, rectangular, triangular) APPLICATION AREA n Ideal for breaking up large spaces. Project: International Book Club - City Madrid (SP) :::::::: Architect: Stitzman Staiff, David S. Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Open area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Other perforation patterns available on request. Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 19 :::: :::: 20 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance in terms of sound absorption, sound attenuation and sound reduction. These performance values will depend upon the perforation and the acoustic infill. Please contact us for more information on the available factory fitted acoustic options. Standard colours Cross-section RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss expansion bolt M6 threaded rod M6 ceiling void hexagonal nut M6 Thermal Conductivity crossing-box (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 custom C-profile wall anchor rectangular panel system K-H 400 Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specifications or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. visible side perimeter trim max. M/2 Longitudinal-section Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Environmental Our metal panels have an average of up to 30% recycled content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). expansion bolt M6 threaded rod M6 ceiling void hexagonal nut M6 wall anchor rectangular panel system K-H 400 Sustainability Acoustics Safe & Healthy perimeter trim % max. M/2 Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity resistance (%) up to Cleanability up to Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) Premium B15 Premium OP19 up to 30 85 up to 30 depends on perforation up to 30 depends on perforation 0.10(L) 0.65 1.00 Not Classified C A 0.10 0.60 0.90 crossing-box custom C-profile 44 41 31 19 20 15 A1 A2-s1, d0 A2-s2, d0 95 scrubbable 95 wipeable moist cloth 95 wipeable moist cloth Bioguard paint option Scratch resistance ✔ ✔ M = module size / A = panel length / B = panel width Item No. BPM 215004 customised ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ ✔ ✔ Designation crossing-box 100 x 100 mm custom C-profile 100 mm BPM 300144 wall anchor BPM 311111 expansion bolt M6 x 30 mm BPM 311099 threaded rod M6 x 1‘000 mm BPM 311103 hexagonal nut M6 visible side 21 :::: Detail A K-H 400 panel Detail B grid system layout options expansion bolt M6 Fall 1 Fall A threaded rod M6 wall anchor Fall A Fall 1 hexagonal nut M6 crossing-box Module with 1 mega panel Module with 2 rectangular panels Module with 2 rectangular panels and light integration Module with 3 rectangular panels Module with 4 rectangular panels Module with 4 square tiles (suspended by a J-bar in the middle) Module with a diagonal custom C-profile and 2 triangular panels Module with 4 elements to build up a truncated pyramid, with a centre tile or service integration Module with octagonal crossing-boxes and diagonal custom C-profile, with 4 triangular panels custom C-profile For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet optional K-H 400 Easy panel with hinge-down function optional K-H 400 Swing panel with swing-down function Metal product CI/SfB (35)Xy 11/2015 r-h 200 system Rectangular panels / planks :::: 25 R-H 200 SYSTEM RECTANGULAR PANELS / PLANKS Specification System Armstrong ceiling system R-H 200, Hook-On solution with concealed grid, suspension height min. 105 mm Panel material galvanised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or other materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* rectangular panel square edged long sides CA / DA (40 - 55 mm) short sides E1 / F4 (30 mm) Gap solution 3 mm gap, with black gasket on one long and one short side Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Standard modules 1800 x 400 mm 2100 x 400 mm 2400 x 400 mm 2700 x 400 mm 3000 x 400 mm Configurable dimensions panel length (A) 600 - 3000 mm panel width (B) 275 - 1350 mm Grid system U-profile + J-bar, security bracket optional available, further suspension methods on request Perimeter solution Range of standards trims in steel and aluminium plus custom bulkheads available. Service integration standard round or rectangular cut-outs plus customised options on request. Special capabilities - trapezoidal panel solution - curved panel solution - segmented vault or wave ceiling solution - can be combined with other Armstrong products * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns BENEFITS n Versatile system and simple design n Concealed grid for a monolithic effect n Good acoustic properties n Ease of installation (alignment) and fully demountable n Easy access to the ceiling void n Maintenance friendly system Project: The City of St. Gallen (CH) CONTRACTOR: Phonex AG APPLICATION AREA n Suitable for large open plan / circulation areas Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Open area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Other perforation patterns available on request. Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 26 :::: :::: 27 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance in terms of sound absorption, sound attenuation and sound reduction. These performance values will depend upon the perforation and the acoustic infill. Please contact us for more information on the available factory fitted acoustic options. Standard colours Cross-section RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Expansion bolt M6 Ceiling void Threaded rod M6 Hanger for J-bar Plug-in clip Thermal Conductivity Wall anchor (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece RAL 9010 Global White RAL 9006 U-profile Clamping bracket RAL 9007 Special colours Other RAL and NCS colours available on request J-bar Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Perimeter trim Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specifications or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. R-H 200 rectangular panel Visible side Longitudinal-section Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Environmental Our metal panels have an average of up to 30% recycled content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Expansion bolt M6 Threaded rod M6 Ceiling void Clamping bracket R-H 200 rectangular panel Sustainability Acoustics Safe & Healthy Perimeter trim % Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity resistance (%) up to Cleanability up to Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) Premium B15 Premium OP19 up to 30 85 up to 30 depends on perforation up to 30 depends on perforation 0.10(L) 0.65 1.00 Not Classified C A 0.10 0.60 0.90 U-profile J-bar 44 47 31 19 21 15 A1 A2-s1, d0 A2-s2, d0 95 scrubbable 95 wipeable moist cloth 95 wipeable moist cloth Bioguard paint option Scratch resistance ✔ ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ ✔ ✔ Visible side M = module size / A = panel length / B = panel width Item No. Designation Item No. Designation BPM 300100 U-profile BPM 300026 J-bar BPM 300119 Connector for U-profile BPM 300343 Connector for J-bar BPM 300120 Plug-in clip BPM 300307 Hanger for J-bar BPM 300140 Wall anchor BPM 311303 Hexagonal bolt M6 x 16 mm BPM 300121 Clamping bracket BPM 311103 Hexagonal nut M6 BPM 311111 Expansion bolt M6 x 30 mm BPM 311305 Washer M6 18 x 1.6 mm BPM 311099 Threaded rod M6 x 1‘000 mm BPM 300216 Security bracket BPM 300208 Extraction tool for R-H 200 28 :::: Detail A R-H 200 panel Detail B Security clip option Fall 1 R-H 200 rectangular panel Fall A J-bar Security clip Fall A Fall 4 Extraction tool Detail C Grid system Detail D Suspension methods Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Expansion bolt M6 Threaded rod M6 Clamping bracket Plug-in clip Wall anchor Connector for U-profile Connector for J-bar U-profile Plug-in clip Hanger for J-bar J-bar Clamping bracket Hanger for U-profile Combi Nonius hanger with Nonios top-part Combi Nonius hanger with eye wire Project: The City of St. Gallen (CH) CONTRACTOR: Phonex AG Metal product CI/SfB (35)Xy 11/2015 r-h 215 system Rectangular panels / planks :::: 32 R-H 215 SYSTEM RECTANGULAR PANELS / PLANKS Specification System Armstrong ceiling system R-H 215, Hook-On solution with concealed grid, with optional revision opening Power Swing, suspension height min. 100 mm Panel material galvanised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or further materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* rectangular panel square edged long sides CA / DA (40 - 55 mm) short sides E8 / F8 (12 mm) Gap solution 3 mm gap, with black gasket on one long and one short side Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Standard modules 1800 x 400 mm 2100 x 400 mm 2400 x 400 mm 2700 x 400 mm 3000 x 400 mm Configurable dimensions panel length (A) 600 - 3000 mm panel width (B) 275 - 1350 mm Perimeter solution Range of standards trims in steel and aluminium plus custom bulkheads available. Service integration standard round or rectangular cut-outs plus customized options on request. Special capabilities - trapezoidal panel solution - facetted ceiling solution - can be combined with other Armstrong products Grid system U-profile + H-profile 35, security bracket optional available, further suspension methods on request * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns BENEFITS n Versatile system and simple design n Concealed grid for a monolithic effect n Good acoustic properties n Ease of installation (alignment) and fully demountable n Easy access to the ceiling void n Maintenance friendly system APPLICATION AREA n Suitable for large open plan / circulation areas Project: Train station Zürich Löwenstrasse (CH) :::::::: Architect: Dürig AG Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Open area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Other perforation patterns available on request. Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 33 :::: :::: 34 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a variety of factory fitted acoustic infill options. Please contact us for more information. Standard colours Cross-section 20% gloss 12% gloss 30% gloss 30% gloss expansion bolt M6 ceiling void threaded rod M6 Thermal Conductivity (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece plug-in clip hanger for H-profile 35 wall anchor RAL 9010 Global White RAL 9006 U-profile clamping bracket RAL 9007 Special colours Other RAL and NCS colours available on request ~67 Up to 95% RH (for short term exposure). H-profile 35 Quality Standard Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. perimeter trim Armstrong is a certified EN ISO 9001:2008 Quality Assumed Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. rectangular panel system R-H 215 max. M/2 Longitudinal-section Environmental Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). expansion bolt M6 threaded rod M6 ceiling void clamping bracket Acoustics H-profile 35 U-profile ~67 rectangular panel system R-H 215 Sustainability visible side Safe & Healthy perimeter trim visible side % max. M/2 Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity Resistance (%) up to Cleanability up to Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Bioguard paint option Scratch resistance ✔ ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ M = module size / A = panel length / B = panel width Item No. Designation Item No. Designation BPM 300100 U-profile BPM 311400 H-profile 35 BPM 300119 connector for U-profile BPM 300343 connector for H-profile 35 BPM 300120 plug-in clip BPM 300307 hanger for H-profile 35 BPM 300140 wall anchor BPM 311303 hexagonal bolt M6 x 16 mm BPM 300121 clamping bracket BPM 311103 hexagonal nut M6 BPM 311111 expansion bolt M6 x 30 mm BPM 311305 washer M6 18 x 1.6 mm BPM 311099 threaded rod M6 x 1‘000 mm BPM 300216 security bracket 98 Humidity Exposure 98 RAL 9010 Global White RAL 9006 RAL 9007 35 :::: Detail A R-H 215 panel Detail C grid system hexagonal bolt M6 hexagonal nut M6 washer M6 Fall 8 Fall A Detail E suspension methods expansion bolt M6 threaded rod M6 clamping bracket plug-in clip Fall A Fall 8 wall anchor connector for U-profile connector for H-profile 35 Detail B R-H 215 Power Swing panel Fall 2 Fall A plug-in clip U-profile Fall A hanger for H-profile 35 clamping bracket with threaded rod U-profile hanger with threaded rod combi Nonius hanger with Nonius to part combi Nonius hanger with eye wire H-profile 35 Fall 2 For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet optional R-H 215 Power-Swing panel with swing-down function as revision opening Detail D security bracket H-profile 35 rectangular panel system R-H 215 security bracket Project: OBERWAID Health resort & Medical Center, St Gallen (CH) :::::::: Architect: Carlos Martinez Architekten AG SOLUTION: R-H 215 Plain Metal product CI/SfB (35)Xy 11/2015 D-H 700 system Floating Ceilings :::: 39 D-H 700 SYSTEM Floating Ceilings Specification System Armstrong ceiling system D-H 700, Island Hook-On solution with concealed grid, suspension height min. 105 mm Panel material galvanised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or other materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* standard panel rectangular panel square edged long sides CA / DA (30 - 50 mm) not visible, short sides E4 / F4 (50 mm) visible Execution* end panel rectangular panel square edged one long side CA (30 - 50 mm not visible, one long side DA (50 mm) visible short sides E4 / F4 (50 mm) visible Execution* single panel rectangular panel square edged long sides CA / DA (50 mm) visible short sides E4 / F4 (50 mm) visible Gap solution 0 mm gap, without gasket Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Configurable dimensions panel length (A) 600 - 2750 mm (in steps of 25 mm) panel width (B) 250 - 600 mm (in steps of 25 mm) Grid system U-profile cross-connected with security bracket to secure end panels Service integration standard round or rectangular cut-outs plus customised options on request Special capabilities - chilled ceiling solution - can be combined with other Armstrong products * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns BENEFITS n Modular concept for optimum flexibility n Visually defines a space n Freedom in design n Modern absorber solution for exposed soffits n Meets demanding acoustic requirements n Integration of lighting, air conditioning and other equipment n Quick and easy to install APPLICATION AREA n A contemporary design and acoustic solution for all market segments. Chilled beams or chilled ceiling elements can be integrated within D-H 700. Project: Siemens, Roma (IT) :::::::: Architect: SPA Group Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Other perforation patterns available on request. Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 40 :::: :::: 41 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a variety of factory fitted acoustic infill options. Please contact us for more information. Standard colours Cross-section RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss expansion bolt M6 threaded rod M6 Thermal Conductivity ceiling void (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 cross-connector for U-profile plug-in clip Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). 2 x thread cutting screw M6 2 x hexagonal nut M6 hanger for U-profile plug-in clip U-profile Quality Standard Services Integration Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specifications or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. thread cutting screw M6 rectangular panel system D-H 700 visible side U-profile Longitudinal-section Environmental Our metal panels have an average of up to 30% recycled content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). expansion bolt M6 threaded rod M6 ceiling void 2 x hexagonal nut M6 hanger for U-profile Sustainability security bracket 2 x plug-in clip cross-connector for U-profile 2 x thread cutting screw M6 Safe & Healthy end panel system D-H 700 standard panel system D-H 700 % ISO 14021 For chilled ceilings or additional acoustic inlays the bending height of the panel will change from 50mm to 65mm. Recycled content (%) Light reflectance (%) Fire reaction Humidity resistance (%) up to Cleanability Bioguard paint option Scratch resistance Extra Microperforation Rg 0701 (2) up to 30 80 A2-s2, d0 95 wipeable moist cloth (3) ✔ ✔ Microperforation Rd 1522 (2) up to 30 65 A2-s2, d0 95 wipeable moist cloth (3) Standard Perforation Rg 2516 (2) up to 30 U-profile 70 A2-s2, d0 95 Item No. ✔ wipeable moist cloth (3) Plain / Unperforated (1) up to 30 85 A1 95 scrubbable Premium OP19 up to 30 depends on perforation A2-s2, d0 95 wipeable moist cloth ✔ ✔ ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. Designation Item No. Designation BPM 300100 U-profile BPM 311099 threaded rod M6 x 1‘000 mm BPM 300119 connector for U-profile BPM 311103 hexagonal nut M6 BPM 300120 plug-in clip BPM 315710 cross-connector for U-profile BPM 300366 hanger for U-profile BPM 311195 thread cutting screw M6 x 10 mm BPM 311111 expansion bolt M6 x 30 mm BPM 315711 security bracket H = 50 mm visible side 42 :::: Detail A D-H 700 standard panel Detail D grid system Fall 4 Fall A U-profile expansion bolt M6 cross-connector for U-profile Fall A threaded rod M6 2 x hexagonal nut M6 connector for U-profile Fall 4 hanger for U-profile security bracket (for end panels only) Detail B D-H 700 end panel 2 x plug-in clip 4 x thread cutting screw M6 Fall 4 Fall A plug-in clip 2 x plug-in clip 2 x plug-in clip Fall A Fall 4 Detail C D-H 700 single panel Fall 4 Fall A Fall A Fall 4 For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet Modular option 1 Modular option 2 Single panel End panel End panel End panel Standard panel Standard panel Standard panel Standard panel End panel layout options Single panel option PROJECT : Siemens, Roma (IT) :::::::: ARCHITECT : SPA Group Belgium & Luxembourg Armstrong Building Products B.V. Postbus 3803 4800 DV Breda Netherlands Tel.: +32 02 223 00 72 Fax: +31 (0) 76 521 04 07 e-mail: benelux-info@armstrong.com www.armstrongplafonds.be Germany & Switzerland Armstrong Building Products Kundenservice Office Building Quadrium Claudius Prinsenlaan 126 4818 CP Breda Netherlands Tel.: +49 (0) 251 7603 210 Fax: +49 (0) 251 7603 593 e-mail: deutsche-info@armstrong.com www.armstrongdecken.de www.armstrong-decken.at www.armstrong.ch Firmensitz Armstrong Building Products GmbH Robert-Bosch-Str. 10 48153 Münster Germany Armstrong Metalldecken AG Breitfeldstrasse 8 9015 St. Gallen Switzerland Tel.: +41 (0) 71 313 63 63 Fax: +41 (0) 71 313 64 00 e-mail: gema@armstrong.com www.armstrong.ch www.gema.biz Zentralschweiz Armstrong Metalldecken AG Büro / Lager Zentralschweiz Grossweid 9 6026 Rain Switzerland Tel.: +41 (0) 41 921 63 63 Fax: +41 (0) 41 921 63 80 e-mail: gema@armstrong.com www.armstrong.ch www.gema.biz Armstrong Plafonds Métalliques SA Bureau et Dépôt Suisse Romande Avenue de Châtelaine 87 1219 Châtelaine Suisse Tel.: +41 (0) 22 731 60 70 Fax: +41 (0) 22 731 60 74 e-mail: gema@armstrong.com www.armstrong.ch www.gema.biz Austria Armstrong Metalldecken GmbH Bundesstrasse 70 6830 Rankweil Austria Tel.: +43 (0) 55 22 34 44-0 Fax: +43 (0) 55 22 34 44-8 e-mail: gema@armstrong-decken.at www.armstrong-decken.at www.gema.biz Armstrong Metalldecken GmbH Messendorferstrasse 6 8041 Graz Austria Tel.: +43 (0) 316 471 584 Fax: +43 (0) 316 471 584-10 e-mail: gema@armstrong-decken.at www.armstrong-decken.at www.gema.biz Spain & Portugal Armstrong Building Products SAS Immeuble Paryseine 3, allee de la Seine 94854 Ivry-sur-Seine Cedex France Phone: + 34 91 642 04 99 info-espana@armstrong.com www.armstrongtechos.es France Armstrong Building Products SAS Bureaux Commerciaux France Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-Seine France Tel.: 0800 41 36 43 Fax: +33 1 45 21 04 11 e-mail: info-France@armstrong.com www.armstrongplafonds.fr Siège social Armstrong Building Products SAS 67 rue de Salins – CS 20089 25302 Pontarlier Cedex France Italy & Greece Armstrong Building Products Uffi cio Commerciale Italia Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-Seine France Tel.: +39 02 66 22 76 50 Fax: +39 02 66 20 14 27 e-mail: info-italia@armstrong.com www.armstrongsoffitti.it Netherlands Armstrong Building Products B.V. Postbus 3803 4800 DV Breda Netherlands Tel.: (+31) 076 523 02 00 Fax: (+31) 076 521 04 07 e-mail: benelux-info@armstrong.com www.armstrongceilings.nl United Kingdom Armstrong World Industries Ltd Building Products Division Armstrong House 38 Market Square Uxbridge UB8 1NG United Kingdom Tel.: 0800 371 849 Fax: +44 1895 274287 e-mail: sales-support@armstrong.com www.armstrongceilings.co.uk Republic of Ireland Armstrong World Industries Ltd. 108 Greenlea Road Terenure Co Dublin 6W Ireland Tel.: 1800 409002 Tel.: (+353) 1 499 1701 Fax: (+353) 1 490 7061 e-mail: sales-support@armstrong.com www.armstrongceilings.ie Central Europe North (DK/EE/FIN/IS/LT/LV/N/PL/S) Armstrong Building Products BV Sp. z o.o. Oddział w Polsce ul. Domaniewska 37 02-672 Warszawa Poland Tel.: (+48) 22 337 86 10/ 86 11 Fax: (+48) 22 337 86 12 e-mail: service-ce@armstrong.com Latvia: www.armstrong.lv Lithuania: www.armstrong.lt Norway: www.armstrong.no Poland: www.armstrongsufity.pl Sweden: www.armstrong.se Central Europe South (AL/BA/BG/CZ/HR/HU/KO/ MD/ME/MK/RO/RS/SK/SI) Armstrong Building Products Lighthouse building, Jankovcova 1569/2c, 170 00 Praha 7, Czech Republic Tel.: +420 725 477 588 e-mail: service-ce@armstrong.com Czech Republic: www.armstrong.cz Hungary: www.armstrong.co.hu Romania: www.armstrong.ro Serbia: www.armstrong.rs Slovakia: www.armstrong.sk Slovenia: www.armstrong.si www.armstrongceilings.eu Eastern Europe CIS Armstrong Moscow GmbH Mosfi lmovskaya Street 38A, Moscow 119285, Russian Federation Tel.: +7 (495) 258 5100 Fax: + 7 (495) 258 5103 e-mail: info-cis@armstrong.com Russian Federation: www.armstrongceilings.ru MIDDLE EAST / AFRICA / TURKEY Armstrong World Industries Ltd Africa Middle East Turkey Division Armstrong House 38 Market Square Uxbridge UB8 1NG Tel.: +44 01895 202097 Fax: +44 01895 272928 e-mail: sales-support@armstrong.com www.armstrong.eu Israël: www.armstrong.co.il South Africa: www.armstrong-ceilings.co.za Middle East Regional Office, Dubai, UAE & French Speaking Africa Offi ce No. 2003, 20th Floor Gold Crest Executive Tower Jumeirah Lakes Towers P.O. Box 73831 Dubai, United Arab Emirates Tel.: +971 4 453 4545 Fax: +971 4 453 4546 info-me@armstrong.com www.armstrong.ae Turkey Armstrong Europa GmbH Mimar Sinan Mah. Mimar Sinan Cad. No: 35/2 Cekmekoy Istanbul Turkey Gsm: +90 542 772 49 22 Gsm: +90 544 293 5931 www.armstrong.com.tr etulpar@armstrong.com 10/2015 - PAS1205 - Armstrong Building Products - RCS Besançon B 784 131 575 Printed on chlorine free paper. Western Europe