Stop Motor Burnouts!

advertisement
ICM400
T HREE -P HASE V OLTAGE M ONITOR
Stop Motor Burnouts!
High performance, low cost model, front and
back side protection, 7 bright fault LEDs,
integral short-cycle protection, easy set up, fully
adjustable features, 190 to 630 VAC...
3-Position Reset Switch, 50/60 Hz...
• Choose from 3 easy-to-select reset modes
– Full Manual, Full Automatic, Auto Front/Manual Back
Features
Specifications
• Bright LEDs Show Modes and Identity Faults
– Load energized LED
– Lockout LED
– Back fault LED
– Low voltage LED
– Control voltage LED
– Front fault LED
– High voltage LED
• Knob-adjustable Variables
–User may easily select and adjust setpoints on unit:
• Line voltage: 190 to 600 VAC
• Voltage unbalance: 2 to 25%
• Delay on break period: .1 to 5 minutes
• Fault interrogation: 1 to 15 seconds
• Low Cost, High Performance
–Full line protection and fault identification without
costly LCD readout
• Integral Delay on Break Timer
–Knob-adjustable from .1 to 5 minutes, helps prevent
rapid system recycling
• Easy to Install and Configure
–Wiring diagram on unit
–Installation and application guide included
Mode of Operation
At power up, the ICM400 evaluates the incoming power for
proper phase sequence, amplitude, and symmetry (voltage
unbalance). If the three phase input at the line side connections
is within user set parameters, the internal relay is energized and
the load energize LED is turned on. Continuity will be across
terminals 4 and 6.
If connections are made to the load side terminals, the ICM400
will transfer monitoring over to the load side only. When a critical
fault condition (phase loss or phase reversal) is present, the relay
will immediately de-energize and the load energize LED will turn
off. Continuity will be across terminals 4 and 5.
If a non critical fault condition (unbalance, high or low voltage)
is present, the ICM400 will ignore it for the interrogation delay
time. If it is still present following the interrogation delay time,
the relay will de-energize and the load energized LED will turn
off. Continuity will be across terminals 4 and 5. The relay will
not energize if any fault conditions exist. The integral adjustable
delay on break timer will prevent short-cycling.
LIS41-1
Phone
315.233.5266
Input
• Line Voltage: Universal (190-630 VAC)
• Frequency: 50/60 Hz
Output
• Type: Relay
• Form: SPDT
• Voltage Range: 240 VAC (maximum: 10 amps)
• Frequency: 50/60 Hz
Contactor Load Side (Back)
• Line Voltage: Universal (190-630 VAC)
• Frequency: 50/60 Hz
• Load side monitoring is optional
Control Operating Temperature
• Operating Temperature: -40ºC to +75ºC
(-40ºF to +167ºF)
• Storage Temperature: -40ºC to +85ºC
(-40ºF to +185ºF)
Phase Unbalance Protection
• Voltage Unbalance: 2 to 25% adjustable
Over/Under Protection
• Under: Fixed at ±12%
• Over Voltage: Fixed at ±12%
• Hysteresis: ±6%
Phase Loss Protection
• Phase Loss condition = <25% of nominal for any given phase.
System will shut down should this condition occur.
Delay on Break Timer
• Control Voltage: 18-240 VAC
• Time Delay: .1 to 5 minutes adjustable
Fault Interrogation Delay
• Time Delay: 1 to 15 seconds adjustable
• Provides a delay between fault detection and system shutdown,
eliminating nuisance trips/unnecessary shutdowns
Mechanical
• Mounting: Surface mount using (2) #8 screws
• Termination: Screw terminals
• Weight: 12 ounces (341 grams)
• Dimensions: 6.5” x 4.25” x 1.4” (16.5 x 10.8 x 3.5 cm)
Installation and Setup
• Application Guide included with unit
All features and specifications subject to change without notice.
Application Assistance
800.365.5525
visit us at: www.icmcontrols.com
Fax
315.233.5276
Wiring Diagram
LI1
LI2
LI3
LINE LINE LINE
3
2
1
LOAD LOAD LOAD
3
2
1
Control
Voltage
L01
L02
L03
* Thermostat, pressure switch, etc.
L0AD
System Diagram
Line
Voltage
Control Transformer
*
LI
NE
0C 3
T
MA HR
DE EE
P
LI
IN PH 1 /N
NE
0B 2
TH A90-6 IC
E SE 30 M40
US V V
A OL A 0
1-80 TAC
5
0-36GE0-6
0H
5-55MO
z
25 NIT
LI
3
LI
2
LI
1
LR
30
32
0
LO
0C AD3
LI
NE
0A 1
OR
LO
LO
0B AD2
1
LO
IN
TE
IN RRFAUL
SE OG T
CO AT
ND IO
S N
2
LO
3
LO
0A AD1
48
0
38
5
E
EN LO
ER AD
D GIZE
AM
P
CO
M
AD
57
30
10
JU
5
ST
0
0
20 190
8
UN% VO
BA LT
LA AG
NC E
E
CO
VO
19 LTNTRO
-24 AG
0 VA E L
C
8%
25
%
IN
FO JUMSTAL
2%
R
24 PER L
AN CO
VA
TY TI OL
C
PE CIPA IN
T’S TOG
TA R
T
1
Contactor
3
4
60
8
6%
4%
.1
LT
AG
0
23
4
LO
CK
15
FR OU
FA ON T
UL T
FABACK T
1
VO HI ULT
LT GH
AG
VO LO
E
LT W
AG
E
3
VO
1
12
9
6
RE
FR SE
M ON T
AU AN T BAMOD
TO
CK E
M
AU AN
TO
TI LO
M
CK
MINE DE OU
UT LA T
ES Y IN
3
2
AL
5
RU
6
AR
M
N
Thermostat
Compressor
* Install jumper for 24 VAC anticipator type thermostats.
Download