Timers P111644 P111643 P111642 Just enough light ! Time switches Contents Presentation 2 Choice table MIN, MI Ns, MINp, MINt and PRE switch-off warning 4 Technical data MIN MINs MINp, MINt PRE switch-off warning 5 6 7 8 Dimensions UT00656EN MIN, MINs, MINp, MINt and PRE switch-off warning 9 version: 2.1 Just enough light! By automatically switching off lighting, ventilation, etc. after a user-set time delay, MIN timers provide both savings and comfort. Since several control push-buttons may be connected, MIN timers are ideal for controlling stairway lighting. Energy savings Whatever the type of building or infrastructure, it is important nowadays to optimize your energy costs. With the MIN timer’s adjustable time delay, you can optimize your lighting and avoid pointless consumption. Energy savings can be improved using the MINt impulse relay function to reduce even more the time the load is switched on. Stairway, corridor or hall lighting Easy installation Extremely simple to implement and install, the timers fit all electrical and modular enclosures. P111649 For MINs, MINp and MINt, mechanical compatibility with the electrical distribution comb busbar makes installation easier. Convenient use MIN timers are used to manage and control lighting whenever you wish. One or more light sources may be controlled from one or more points. They are controlled by simply pressing a push-button. The switch-off warning function prevents you from finding yourself in the dark at the end of the time delay. version: 2.1 UT00656EN P111648 > MIN P111642 Electromechanical timer, adjustable time delay from 1 to 7 min. Silent electronic timer, adjustable time delay from 0.5 to 20 min. > PRE P111646 Switch-off warning, only used with MIN and MINs. P111643 P111644 UT00656EN > MINs > MINp Silent electronic timer with switch-off warning, adjustable time delay from 0.5 to 20 min. > MINt Silent electronic timer with switch-off warning and impulse relay function, adjustable time delay from 0.5 to 20 min. version: 2.1 Timers MIN, MINs, MINp, MINt, PRE Choice table MIN, MINs These timers allow closing and then opening of a contact in a determined time. MINp, MINt This timer allows closing and then opening of a contact in a determined time, and it also provides warning that the lighting is about to be switched off by flickering of the lamplight. (switch-off warning). The MINt timer is the same as MINp with an “impulse relay” additional function (see ”MINt” technical data). PRE This is used in association with MIN or MINs timers and only on incandescent lighting circuits (not used on fluorescent, fluocompact lamps and very low voltage halogen lamps). It provides warning that the lighting is about to be switched off by reducing the brightness by 50 % during the 20 to 60 s warning time. Catalogue numbers MIN MINs MINp MINt PRE 15363 CCT15232 CCT15233 CCT15234 15376 230 V AC 50 Hz 1 to 7 min. 230 V AC 50/60 Hz 0.5 to 20 min. < 6 VA 16 A -25 to +50 °C 2 ■ Automatic ■ 230 V AC 50/60 Hz 0.5 to 20 min. 1h < 6 VA 16 A -25 to +55 °C 2 ■ Automatic ■ ■ ■ 230 V AC 50/60 Hz 20 to 60 s 1 VA 16 A -10 to +50 °C 2 ■ Selector switch 230 V AC 50/60 Hz 0.5 to 20 min. 1h < 6 VA 16 A -25 to +55 °C 2 ■ Automatic ■ ■ Technical data Voltage (+10 %, -15 %) Frequency Adjustable time delay Long time delay Consumption Switching capacity (cos φ = 1) Operating temperature Width (9 mm modules) 1 screw connection per pole for cables up to 6 mm² Selection of the type of connection (3 or 4 wires) Mechanical compatibility with electrical distribution comb busbar Switch-off warning function Impulse relay function version: 2.1 -10 to +50 °C 2 ■ ■ UT00656EN MIN P111648 Functions These timers allow closing and then opening of a contact in a determined time. Technical data MIN. b v v b b b b b b b b Two operating modes triggered by switch on front face: automatic mode: operation in timing mode, time delay adjustable from 1 to 7 min., setting in steps of 15 s using knob, pressing a push-button renews the time delay. manual override mode: constant lighting. Voltage: 230 V AC ± 10 %. Frequency: 50 Hz. Consumption during operation: 1 VA maxi. Consumption of connected luminous push-buttons: 50 mA maxi. Degree of protection: IP 20B. Operating temperature: -10 °C to +50 °C. Contact rating: 16 A, cos φ = 1. Load table: Type of lighting Max. power 230 V incandescent and halogen lamps Non-corrected/ serial-corrected/ dual mounted fluorescent tubes with conventional ballast Fluocompact lamps with conventional ballast Parallel-corrected fluorescent tubes with conventional ballast Fluorescent tubes with electronic ballast Fluocompact lamps with electronic ballast 2300 W 2300 VA 2000 VA 1300 VA (70 F) 300 VA 9 x 7 W, 6 x 11 W, 5 x 15 W, 5 x 20 W b Control circuit: connected luminous push-buttons; timer inoperative via selfprotection if consumption above 50 mA maximum. b Switch-off warning: external via use of PRE product. Connection b Connection terminals: 1 screw connection per pole for cables up to 6 mm². b Connection type: 3 or 4 wires with selector switch on the side of the product. L L 4 wires L 4 wires 3 N 4 R N or 3 wires L 3 N 4 N A1 A2 3 or R 3 wires MIN + PRE Catalogue number Type MIN Specific shield for terminal blocks insulation UT00656EN version: 2.1 Cat. no. 15363 15359 Timers MINs P111642 Functions These timers allow closing and then opening of a contact in a determined time. Technical data MINs. b v v b b b b b b b b b b b Two operating modes triggered by switch on front face: timer mode: time delay adjustable from 0.5 to 20 min., permanent mode: constant lighting. Pressing on a push-button renews the time delay. Voltage: 230 V AC +10 %, -15 %. Frequency: 50/60 Hz. Consumption during operation: < 6 VA Consumption of connected luminous pushbuttons: 150 mA maxi. Insulation class: class II. Degree of protection: IP 20B. Operating temperature: -25 °C to +50 °C. Contact rating: 16 A, cos φ = 1. Switch-off warning: external via use of PRE product. Load table: Type of lighting Max. power 230 V incandescent and halogen lamps Non-corrected/ serial-corrected/ dual mounted fluorescent tubes with conventional ballast Fluocompact lamps with conventional ballast Parallel-corrected fluorescent tubes with conventional ballast Fluorescent tubes with electronic ballast Fluocompact lamps with electronic ballast 2300 W 2300 VA 1500 VA 400 VA (42 μF) 300 VA 9 x 7 W, 7 x 11 W, 7 x 15 W, 7 x 20 W, 7 x 23 W Connection b Connection terminals: 1 screw connection per pole for cables up to 6 mm². b Connection type: 3 or 4 wires with automatic selection of the control push-button connection. b Mechanical compatibility with electrical distribution comb busbars. L L 4 wires L 4 wires 3 N 4 R N or 3 wires L 3 N 4 N A1 A2 3 or R 3 wires MINs + PRE Catalogue number Type MINs version: 2.1 Cat. no. CCT15232 UT00656EN MINp, MINt P111643 Functions This timer allows closing and then opening of a contact in a determined time, and it also provides warning that the lighting is about to be switched off by flickering of the lamplight. (switch-off warning). The MINt timer is the same as MINp with an “impulse relay” additional function (see ”MINt”). Technical data P111644 MINp. MINt. b Time delay adjustable from 0.5 to 20 min. b Three operating modes triggered by switch on front face: v timer mode with warning function built into the device. The lamp blinks 40 and 30 s before the end of the time delay, v timer mode mode without ”switch-off warning” function, v permanent mode : constant lighting. b Timer mode operation: v pressing a push-button for longer than 2 s: lighting will last for 1h. Pressing again a push-button for less than 2 s relaunch the time delay of 1h and pressing again a push-button for more than 2 s switches off the light. v for MINp, pressing a push-button for less than 2 s launch the pre-set time delay, pressing again a push-button for less than 2 s relaunch the pre-set time delay, v for MINt, pressing a push-button for less than 2 s launch the pre-set time delay, pressing again a push-button for less than 2 s, switches off the light (impulse relay mode). b Voltage: 230 V AC +10 %, -15 %. b Frequency: 50/60 Hz. b Consumption during operation: < 6 VA. b Consumption of connected luminous push-buttons: 150 mA maxi. b Insulation class: class II. b Degree of protection: IP 20B. b Operating temperature: -25 °C to +50 °C. b Contact rating: 16 A, cos φ = 1, b Load table: Type of lighting 230 V incandescent and halogen lamps Non-corrected/ serial-corrected/ dual mounted fluorescent tubes with conventional ballast Fluocompact lamps with conventional ballast Parallel-corrected fluorescent tubes with conventional ballast Fluorescent tubes with electronic ballast Fluocompact lamps with electronic ballast Max. power 3600 W 3600 VA (1) 1500 VA (1) 1200 VA (120 μF) (1) 1000 VA 34 x 7 W, 27 x 11 W, 24 x 15 W, 22 x 23 W (1) The ”switch-off warning” function is not available for these types of loads. Connection b Connection terminals: 1 screw connection per pole for cables up to 6 mm². b Connection type: 3 or 4 wires with automatic selection of the control push-button connection. b Mechanical compatibility with electrical distribution comb busbars. L 4 wires L 3 N 4 R N or 3 wires Catalogue numbers Type MINp MINt UT00656EN version: 2.1 Cat. no. CCT15233 CCT15234 Timers PRE switch-off warning P111646 Functions This is used in association with MIN or MINs timers and only on incandescent lighting circuits (not used on fluorescent, fluocompact lamps and very low voltage halogen lamps). It provides warning that the lighting is about to be switched off by reducing the brightness by 50% during the 20 to 60 s warning time. Technical data PRE. b Only to be used with the MIN et MINs timers. b 50 % reduction in brightness during warning time. b Time adjustable from 20 to 60 s. b Voltage: 230 V AC ± 10 %. b Frequency: 50/60 Hz. b Operating temperature: -10 °C to +50 °C. b Maximum power: 2300 W for incandescent lamps only. b Not compatible with fluorescent lamps, fluocompact lamps and very low voltage halogen lamps. Connection b Connection terminals: 1 screw connection per pole for cables up to 6 mm². b Connection type: 3 or 4 wires. L A1 A2 min 3 R N Catalogue numbers Type PRE Specific shield for terminal blocks insulation version: 2.1 Cat. no. 15376 15359 UT00656EN MIN, MINs, MINp, MINt, PRE Dimensions MIN 5 63 18 38 83 83 45 MINs, MINp, MINt 6 60 44 18 24 85 89 45 72 PRE 60 6 44 18 89 UT00656EN version: 2.1 26 45 73 Notes 10 version: 2.1 UT00656EN Notes UT00656EN version: 2.1 11 Notes 12 version: 2.1 UT00656EN 35, rue Joseph Monier CS 30323 F- 92506 Rueil Malmaison Cedex RCS Nanterre 954 503 439 Capital social 896 313 776 € www.schneider-electric.com UT00656EN As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper Design: Schneider Electric Photos: Schneider Electric Printed: © 2010 - Schneider Electric - All rights reserved. Schneider Electric Industries SAS 01-2010