ENGLISH CAT5 VIDEO INTERCOM SYSTEM Quick Installatin Manual C5-ENG-MR6AT3-V1 090S604 Read this manual through before installation and doing any operation. ATTENTION: This is an Quick Installation Manual, addressing Wiring and Programming of the standard one-building intercom system, for the complete and advanced multi-building systems, please visit our website at www.extel.com?? for the detail technical documents. -1- CONTENT 1. System Wiring ------------------------------------3 2. MR6L Doorstation Installation------------------4 3. C5-F4 Distributor Installation-------------------6 4. AT3 Monitor Installations and Settings-------7 5. Power Supply and Cable------------------------8 6. System Configurations(MR6L)-----------------9 7. Specifications-------------------------------------13 -2- 1. System Wiring Connect to next C5-F4 C5-F4 C5-F4 ML-ML+ L+ L- L+ L- ML+ ML- P+ P+ ON - 18 V DC lock P+ P- SW1 OFF MR6L PS2 -3- 1 2 3 4 5 6 7 8 9 * 0 # 2. MR6L Doorstation Installation The MR6L doorstation is a digital station with 128*128 pixels LCD screen, color CCD camera, night view LED, and digital keypad. Visitors can call the apartment by dial the room number on the keypd or search the namelist on the screen to call. (When the doorstation is in standby, press '9#' to display the user namelist, use the '8' / '0' key to scroll to last/next page, use the 1 to 7 key to call the corresponding room) Users can open the door by using the Unlock Code(the door open password). When the doorstation is in standby, press '#' key, then input the 4 digit password to open the door. Microphone Camera Lens Night view LED LCD screen 1 2 3 4 5 6 7 8 9 * 0 # Digital Keypad Loudspeaker -4- How to open the back cover: How to adjust the camera angle: Mounting Raincover and MR6L: 6 14 m m step 1: fixed the Raincover on the wall step 2: put MR6L into the Raincover 382 mm step 3: screw the block step 4: plug in the block cover 42 mm -5- 3. C5-F4 Distributor Installation The C5-F4 is a 4 output distributor for the C5 system. There are two mounting measures: bar mounting or dirrect wall mounting. 140mm P+ P- Trunk Bus D C B A 88mm C5-F4 distributor A/B/C/D port: Connect to Monitors Trunk Bus: Bus cable input/output. Connect to last C5-F4(or doorstation), and connect to next C5-F4 Power In-use Data P-: Power negative input. (Ground) P+: Power positive input. (15~18V DC) 32mm 36mm upward 62mm 70mm HI 13mm 120 set to 120 for the last C5-F4 on the building, the others must be set to HI. 84mm Dirrect wall mounting: Bar mounting: -6- 4. AT3 Monitor Installations and Settings 1. AT3 monitor mounting: 2. AT3 monitor room address(room code) and time settings: 1.Power the monitor. Enter into the Main --> setup --> installation --> (input password: 2412) to open the configuration page. 2. Input Numbers: use the + / - button to add/minus current digit, press ►button to switch to next digit, after 4 digit are input, press ► button again to confirm. 3. select and enter Room Address... item to modify the room code. alarm monitor setup intercom setup Doorstation Tone -- 01 Camera Tone -- 10 Guard unit Tone -- 05 No Disturb Set -- off Installation... Exit exit H o m e I n t e l l eg e n t S y s t e m H o m e I n t e l l eg e n t S y s t e m installation Alarm in/out delay -- 40 Date and Time set... Room Address... Other settings... Informations... 2412 Password: 0 *** 1 2 3 4 5 * Exit H o m e I n t e l l eg e n t S y s t e m H o m e I n t e l l eg e n t S y s t e m 3. Change AT3 monitor language: 1. Get into the main page, when the 'setup' item is highlighted, press and hold the UNLOCK button for 3 seconds to get into the Language select page. 2. Use the + / - button to scroll up/down, press ► button to confirm the selected language. -7- alarm monitor intercom setup exit H o m e I n t e l l eg e n t S y s t e m 6 7 8 9 0 # 5. Power Supply and Cables The PS2 is the power supply for the system. It provides the power for the doorstation, distributors, monitors and electronic lock. The maximum number of monitors it can support is 20, that is to say, if there are more than 20 moniotrs in the building, additional power supply is needed. ML+, ML- of door station E-lock (power-off-to-unlock type, 13~16V DC) P+, P- of the door station or distributor E-lock (power-on-to-unlock type, 18V DC) ON OFF LK-TEST SW3 L+ L- L+ L- ML+ML- P+ P- AC-IN UNLOCK 18V-OUT DC-OUT SW1 ON OFF 13~15V-OUT BAT+ BAT- AC AC PTR1 GND AC AC 287 mm VR1 100~240 V AC 247 mm Cables and distance: Power supply cable: RVVP 2*1.0 mm2 Distance: from doorstation to the last distributor: 600 m Max. Data Cable: Catalogue-5 cable, 0.5 mm2+ Distance: from doorstation to the last distributor: 200m Max. from distributor to monitor: 30m Max. -8- 6. System Configurations(MR6L) 1. About room code(address): Room Code(also called room address) is a code asign to each monitor, to didentify deferent monitors; each monitor have a unique room code in one buidling.(see the AT3 monitor installation and settings section to set room code) 2. About Debug State: All settings of the doorstation will be done by getting into the Debug State. > > D E B U G S TAT E < < --------------------------#-# Program Guide 0-# Redial Last Nbrs 1-# Download from PC 2 - # D e b u g To o l s [9008] 1 4 7 # 2 5 8 0 3 6 9 * ---------Options---------< > Vo l u m e A d j u s t < > Auto Dial Back < > Display Net Data < ●> D i s p l a y A l a r m < > Guard Unit Online --------------------------- System Ready System Ready Video Entry System Video Entry System When Door Station is in standby, press '#' key input '9008', then input the Admin Code. (66666666 by default) Video Entry System Debug State menu is launched When the screen is Debug State, press '#9009' to exit. 3. About Default Set: The Default Set is very important. When the settings of the doorstation is totally mess up in anyway, the most quick and easy way to solve the problem is to launch the default setting of the doorstation. The default settings is already have all the right settings for one-building system, that means the system will work normally without any additional settings. > > D E B U G S TAT E < < --------------------------#-# Program Guide 0-# Redial Last Nbrs 1-# Download from PC 2 - # D e b u g To o l s ---------Options---------< > Vo l u m e A d j u s t < > Auto Dial Back < > Display Net Data < ●> D i s p l a y A l a r m < > Guard Unit Online >> Program Guide << --------------------------- [1] Configuration --------------------------- [1] [2] [3] [4] [5] [6] [7] [8] [9] -1. -2. -3. -4. -5. -6. -7. -8. -9. Configuration Unlock Setting Monitor Program Information Operating Options Access Security Card Management System Maintain Advanced Config Net Address [001] Multi DS Mode [0] Unlock Timing [1] Monitoring Nbrs [2] Intercom Video [1] Camera Power On [0] Doorplate Mode [1] Admin. Code Default Set --------------------------- --------------------------Press 1~9 to select * Back --------------------------Press 1~9 to select * Back Video Entry System Video Entry System Video Entry System In Debug State, press '#' key twice In Program Guide, press '1' key -9- press '9' key, then input Admin Code and'#'to confirm 4. Change Admin Code(administrator password): The Admin Code is the password to access the doorstation Debug State. The default Admin Code is '66666666'. Note that if the Default Set have been applied, the Admin Code will also be set to default. > > D E B U G S TAT E < < --------------------------#-# Program Guide 0-# Redial Last Nbrs 1-# Download from PC 2 - # D e b u g To o l s ---------Options---------< > Vo l u m e A d j u s t < > Auto Dial Back < > Display Net Data < ●> D i s p l a y A l a r m < > Guard Unit Online >> Program Guide << --------------------------- [1] Configuration --------------------------- [1] [2] [3] [4] [5] [6] [7] [8] [9] -1. -2. -3. -4. -5. -6. -7. -8. -9. Configuration Unlock Setting Monitor Program Information Operating Options Access Security Card Management System Maintain Advanced Config Net Address [001] Multi DS Mode [0] Unlock Timing [1] Monitoring Nbrs [2] Intercom Video [1] Camera Power On [0] Doorplate Mode [1] Admin. Code Default Set --------------------------- --------------------------Press 1~9 to select * Back --------------------------Press 1~9 to select * Back Video Entry System Video Entry System Video Entry System In Debug State, press '#' key twice press '1' press '8' >> [1][8] Change Admin Code Input the new Admin Code and then press '#'key to confirm -------- <********> * Back # Save Video Entry System 5. Change Unlcok Code: There are two Unlock Code can be used, user can use any one of them to open the door. there are '1111' and '2222' by default. > > D E B U G S TAT E < < --------------------------#-# Program Guide 0-# Redial Last Nbrs 1-# Download from PC 2 - # D e b u g To o l s ---------Options---------< > Vo l u m e A d j u s t < > Auto Dial Back < > Display Net Data < ●> D i s p l a y A l a r m < > Guard Unit Online >> Program Guide << --------------------------- [2] Unlock Setting --------------------------- [1] [2] [3] [4] [5] [6] [7] [8] [9] -1. -2. -3. -4. -5. -6. -7. -8. Configuration Unlock Setting Monitor Program Information Operating Options Access Security Card Management System Maintain Advanced Config Unlock Code 1 [1111] Unlock Code 2 [2222] Code Error Alert [0] Code Mode [1] Code Range ... Code Check ... Code Nbrs [0] Change Program Code --------------------------- --------------------------Press 1~9 to select * Back --------------------------Press 1~9 to select... * Back Video Entry System Video Entry System Video Entry System -10- 6. Change doorstation language: There are 8 operating languages can be selected: 0. Chinese 1. English 2. French 3. Portuguese > > D E B U G S TAT E < < --------------------------#-# Program Guide 0-# Redial Last Nbrs 1-# Download from PC 2 - # D e b u g To o l s ---------Options---------< > Vo l u m e A d j u s t < > Auto Dial Back < > Display Net Data < ●> D i s p l a y A l a r m < > Guard Unit Online 4. Spanish 5. German 6. Italian 7. Dutch >> Program Guide << --------------------------- [9] Advanced Config --------------------------- [1] [2] [3] [4] [5] [6] [7] [8] [9] -1. -2. -3. -4. -5. -6. -7. -8. -9. Configuration Unlock Setting Monitor Program Information Operating Options Access Security Card Management System Maintain Advanced config To n e S e l e c t Image Memo Vo i c e M e m o Name List HMC M o n i t o r Ve r s i o n Call Mode L ad nmgi u A n a. gCeo d e Timing [11] [0] [0] [1] [0] [0] [0] [1] --------------------------- --------------------------Press 1~9 to select * Back --------------------------Press 1~9 to select * Back Video Entry System Video Entry System Video Entry System In Debug State, press '#' key twice press '9' press '8' >>[9][8] Language Input the number for each language according to the language table, press '#' to confirm (0~7) * Back 7. Name List function: #Save Video Entry System The namelist can be eddit by using the digital keypad of the doorstation, the input method is similar as mobile phones. By default, the namelist function is on. > > D E B U G S TAT E < < --------------------------#-# Program Guide 0-# Redial Last Nbrs 1-# Download from PC 2 - # D e b u g To o l s ---------Options---------< > Vo l u m e A d j u s t < > Auto Dial Back < > Display Net Data < ●> D i s p l a y A l a r m < > Guard Unit Online >> Program Guide << --------------------------- [9] Advanced Config --------------------------- [1] [2] [3] [4] [5] [6] [7] [8] [9] -1. -2. -3. -4. -5. -6. -7. -8. -9. Configuration Unlock Setting Monitor Program Information Operating Options Access Security Card Management System Maintain Advanced config To n e S e l e c t Image Memo Vo i c e M e m o Name List HMC M o n i t o r Ve r s i o n Call Mode Admin. Code Timing [11] [0] [0] [1] [0] [0] [0] --------------------------- --------------------------Press 1~9 to select * Back --------------------------Press 1~9 to select * Back Video Entry System Video Entry System Video Entry System -11- To use the namelist function, the Name List item must be set to '1'(enable), which is the default setting. >>[9][4] >>[9][4].2 Name List [Add_008] Name List 1. Add 2. Modify - 3. Initialise Line 1: _ [ ] Line 2: [ ] (0~2) Press 1~3 to select * Back #Save Video Entry System Press '2#' to enter * Back #Save Video Entry System (123) * Back #Save Video Entry System Press '1' to add new names, press '2' to modify the existing names, press '3' to initialise to the default. The first 4 digit are for the Room Code input(the address of the room), after 4 digit have been input, it will switch to Line 1 and the input mode will switch to ABC input mode automatically. Line 2 is for the names that are too long for one line. After the name has been input, press '#' to save. Button 1: Button 2: Button 3: Button 4: Button 5: Button 6: Button 7: Button 8: Button 9: Button * : Button 0: Switch the letter between capitalization and lowercase. A, B, C, (a, b, c) D, E, F, (d, e, f) G, H, I, (g, h, i) J, K, L, (j, k, l) M, N, O, (m, n, o) P, Q, R, S, (p, q, r, s) T, U, V, (t, u, v) W, X, Y, Z, (w, x, y, z) Cancel Space blank, İ, Ş, Ç, Ü, Ğ, Ö -12- 7. Specifications Doorstation: ●● Power supply: DC 15~18V (supplied by PS2) ●● Camera Lens 1/3 inch color CCD ●● Power consumption: Standby 0.5W; Working status 15W ●● Screen: 128*128 pixels LCD ●● Video signal: 1Vp-p, 75Ω, CCIR standard ●● Wiring: 6 wires, polar Distributor: ●● Power supply: ●● Power consumption: DC 15~18V (supplied by PS2) Standby 0.3W; Working status 3W Monitor: ●● Power supply for indoor monitor: ●● Power consumption: DC 15~18V (supplied by system) Standby 0.5W; Working status 15W (for kits) ●● Monitor screen: 5 Inch color TFT-LCD ●● Display Resolutions: 960(R, G, B) x 234 pixels ●● Video signal: 1Vp-p, 75Ω, CCIR standard ●● Wiring: 6 wires, polar -13- The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved. C5-ENG-MR6AT3-V1 090S604