Fill level measurement Ultrasonic fill level sensor for liquids and solid materials Type: Sonicont USN Description With the Sonicont USN ACS -CONTROL -SYSTEM GmbH provides an ultrasonic sensor for continuous, non-contact level measurement of bulk solids and liquids. Along with the closed, smooth user interface with optical keys the compact stainless steel case with rotatable display allows optimal usability in any position. The Sonicont USN can be combined with up to 4 freely adjustable switching points and is suitable for measuring ranges from 2 to 8m. This sensor is suitable for a variety of measurement tasks and can be used in all container shapes - and this with an accuracy of ≤ 0.2% resp. 2 mm. The viewing angle optimized 2 „ TFT color display ensures an excellent displaying of the measured values and easy readability. Also the analog output 0 (4) ... 20 mA and 0 .. 10V is switchable. Intelligent data management is possible through the Bluetooth interface and a built-in data logger function to record measured values. USN 050 USN 020 USN 080 The modern transmitter has extensive diagnostic functions for system analysis and still allows easy setup and operation through the clear and easy navigation. The Soncicont USN is also able to detect flow rates and currents. The mathematical formulas for this are already stored in the device. Application • Measurement range: Liquids: USN 020: 2m; USN 050: 5m; USN 080: 8 m Solids: USN 020: 1m; USN 050: 2m; USN 080: 3,5 • High range • Low blocking distance • TFT-Display • Analog output (0)4-20 mA and 4 switching outputs • Accuracy ≤ 0,2% Specials Your benefits • • • • • • Easy installation and operation due to well-arranged menu Large display - values readable from far away Data logger for recording of measured values Closed smooth user interface - no dirt holes Excellent presentation of the measured values Clear text menu navigation solid materials liquids non-contact measurement up to 8m measuring range 0/4...20mA 4x PNP data logger bluetooth Order code . . . . . . . . page |04| ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de |1| Technical data Technical data Power supply: Output 0/4...20 mA: 9..30 VDC, reverse polarity protected Output 0…10 V: 14..30 VDC, reverse polarity protected Stromaufnahme: Output Output Output Output Blocking distance: USN 020: < 0,2m; USN 050: < 0,25m; USN 080: <0,35 m 0/4...20 mA max. 130 mA US = 9 V / S1/S2/S3/S4 0mA / Bluetooth On 0/4...20 mA min. 70 mA US = 9 V / S1/S2/S3/S4 0mA / Bluetooth Off 0...10 V max. 80 mA US = 9 V / S1/S2/S3/S4 0mA / Bluetooth On 0...10 V min. 50 mA US = 9 V / S1/S2/S3/S4 0mA / Bluetooth Off Analog output Signal: (0)4...20mA / 0...10V, adjustable Reaction time: ≤1s Measurement range Liquids: USN 020: 2m; USN 050: 5m; USN 080: 8 m Solids: USN 020: 1m; USN 050: 2m; USN 080: 3,5 m PNP-switching output Number: 0/2/4 depending on the device version Function: PNP-switch on +L Output current: ≤ 250 mA Standby time: ≤1s current limited, short circuit protected Bluetooth Interface Version: Bluetooth 2.1 +EDR Class: 2 Range: ≤ 10m Electrical connection Version: Plug M12 4/5/8pole, depending on the device version Measurement accuracy Linearity deviation: ≤ ± 2 mm oder ±0,2 % of set measuring range (greater) Temperature deviation: ≤ ±0,06% FS / 10 K (Zero / Span) Materials Process connection: (medium contact) PVDF Connection housing: CrNi-Steel User interface: PC/PES Gaskets: (medium contact) EPDM – Etylene-propylene diene monomer Ambient conditions Ambient temperature: -20°C...+50°C Extension Backlight LCD ≤ 80% >> -20°C...+60°C Backlight LCD ≤ 60% >> -20°C...+70°C Process temperatures: -40...+85°C Process pressure ranges: 0,3...2 bar Protection: IP68 [≤ 1 mWs-1h] EN/IEC 60529 Connection Signal 0/4…20 mA / 0…10 V Wire colors standard connection cable M12: BN = brown, WH = white, BU = blue | 2 | Signal 0/4…20 mA / 0…10 V / 2x PNP switching output Wire colors standard connection cable M12: BN = brown, WH = white, BU = blue, BK = black, GY = grey Signal 0/4…20 mA / 0…10 V / 4x PNP switching output Wire colors standard connection cable M12: WH = white, BN = brown, GN = green, YE = yellow, GY = grey, PK = pink, BU = blue, RD = red ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de Type: Dimension drawings Connection housing Sonicont USN Type G10 G 1“ ISO 228-1 Type G15 G ½“ ISO 228-1 Type G20 G 2“ ISO 228-1 ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de |3| Order code model 020 measuring range liquid up to 2m / solid up to 1m 050 measuring range liquid up to 5m / solid up to 2m 080 measuring range liquid up to 8m / solid up to 3,5m process connection G10 G 1“, ISO 228-1 (only at USN 020) G15 G 1½“, ISO 228-1 (only at USN 050) G20 G 2“, ISO 228-1 (only at USN 080) M K R electronic - output 3-wire, signal 0/4…20mA - 0…10V 3-wire, signal 0/4…20mA - 0…10V, 2x PNP 3-wire, signal 0/4…20mA - 0…10V, 4x PNP 0 1 2 3 Y electronic - function without Bluetooth-Interface Data logger with time stamp, battery powered Bluetooth-Interface / Data logger with time stamp, battery powered others material process connection (medium contact) PVDF / steel 1.4404/316L or 1.4571/316Ti P C material connection housing CrNi-Steel S electrical connection plug M12 Order code Equipment | 4 | USN P Order information LKZ0405PUR-AS LKZ0410PUR-AS LKZ0505PUR-AS LKZ0510PUR-AS LKZ0805PUR-AS BKZ0412-VA BKZ0512-VA C S model connection cable 5 m, 4-pole, shielded connection cable 10 m, 4-pole, shielded connection cable 5 m, 5-pole, shielded connection cable 10 m, 5-pole, shielded connection cable 5 m, 8-pole, shielded Matching cable socket, VA-nut Matching cable socket, VA-nut (at 0...10 V) ACS-CONTROL-SYSTEM GmbH | Lauterbachstr. 57| 84307 Eggenfelden | +49 (0)8721 / 9668-0 | www.acs-controlsystem.de | info@acs-controlsystem.de Stand 01/2013 Sonicont