65 BENDING RADIUS Radius (R) Outer diameter (D) During installation During installation During installation Fixed instalation Fixed instalation (Unarmoured or unscreened cables) R = 6x D R = 6x D R = 9x D R = 4x D R = 6x D LKSM-HF During installation LKSM-EMC Fixed instalation LKSM-VFD LKMSM-HF LKAM-HF LKSM-FRHF LKAM-FRHF RFE-HF RFE-HF(i) RFA-HF RFA-HF(i) RFE-FRHF RFE-FRHF(i) RFA-FRHF RFA-FRHF(i) PBS (Armoured or screened cables) R = 9x D R = 6x D Cable outer diameter, mm. 1 – 10 10,1 – 20 20,1 – 30 Tolerance ±0,5mm ±1,0mm ±1,5mm Cable outer diameter, mm. 30,1 – 40 40,1 – 50 50,1 – 60 < 25mm < 25mm > 25mm < 25mm > 25mm 8/2010 DIAMETER TOLERANCE LKM-HF LKMM-HF LKM-FRHF LKEM-HF Tolerance ±2,0mm ±2,5mm ±3,0mm CORE IDENTIFICATION 0,6/1kV Normal type G-type with earth conductor) 1-core BK 2-cores BN BU 3-cores BN BK 4-cores 5-cores GY Y/G BU BN BU BN Y/G BN GY BK GY BK 1 3 Y/G BU GY BN BK 3 Y/G 4 6 5 4 2 2 7-cores and above 7 6 1 2 5 Black numbers on white base 3 1 4 5 Black numbers on white base Last core yellow/green. BU = Blue, BN = Brown, BK = Black, GY = Grey, Y/G = Yellow/Green 250V Pair number 1 2 3 4 5 6 etc. 60V (PBS) TECHNICAL INFORMATION Recommended minimum bending radius, ( R ) : a b 1 3 5 7 9 11 2 4 6 8 10 12 TECHNICAL INFORMATION 66 CURRENT RATING "Current rating (A) at an ambient temperature of 45°C according to the standard IEC 60092-352 0,6/1 kV +90°C marine cables." Current carrying capacities in continous service at maximum rated conductor temperature of +90°C. For class 2 conductor cables Size N Factor, n mm2 8/2010 For continuous service. Continuous service for a cable is to be considered as a current-carrying service (with constant load) having a duration longer than three times the thermal time constant of the cable, i.e. longer than the critical duration(see short time duty). 1,5 2,5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 25 mm2 35 mm2 50 mm2 70 mm2 95 mm2 120 mm2 150 mm2 185 mm2 240 mm2 300 mm2 1 2 3 4 5 7 10 12 14 16 19 24 27 37 1 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 0,85 20 26 34 44 61 82 108 133 167 206 249 288 331 377 444 511 0,7 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421 0,7 16 21 28 36 50 67 89 110 137 169 205 237 272 311 365 421 0,58 13 17 23 30 42 56 – – – – – – – – – – 0,52 12 16 – – – – – – – – – – – – – – 0,46 11 14 – – – – – – – – – – – – – – 0,44 10 13 – – – – – – – – – – – – – – 0,41 9 12 – – – – – – – – – – – – – – 0,40 9 12 – – – – – – – – – – – – – – 0,37 9 11 – – – – – – – – – – – – – – 0,35 8 11 – – – – – – – – – – – – – – 0,33 8 10 – – – – – – – – – – – – – – 0,30 7 9 – – – – – – – – – – – – – – For class 5 conductor cables Size N Factor, n 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 For class 5 conductor cables 1 2 3 4 5 1 94 123 153 196 240 284 0,85 80 105 130 167 204 241 0,7 66 86 107 137 168 199 0,7 66 86 107 137 168 199 0,58 55 – – – – – Size N Factor, n 120mm2 150mm2 185mm2 240mm2 300mm2 1 2 3 4 5 1 331 381 429 507 582 0,85 281 324 365 431 495 0,7 232 267 300 355 407 0,7 232 267 300 355 407 0,58 – – – – – SHORT CIRCUIT CURRENT Maximum permissible short circuit current. 0,6/1 kV +90°C marine cables. Based on formula: Ik = 226 X S t X S t X In 234 + Tk 234 + Tb Formula 1: Ik = 146 Ik S t Tk = = = = Maximum permissible short circuit current. Cross-section of the conductor in mm2. Duration of the short circuit in s. Maximum rated conductor temperature, short circuit, °C Tb = Maximum rated conductor temperature, normal, °C Formula 1: For 0,6/1kV cable with XLPE or HF90 with maximum operating temperature of +90°C (Tb) and short circuit temperature of +250°C (Tk). Cross-section of the conductor in mm2 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Duration of the short circuit in s. 0,2 0,5 0,8 1,3 2,0 3,3 5,2 8,2 11,4 16,3 22,9 31,0 39,2 49,0 60,4 78,4 97,9 0,5 1 2 3 0,3 0,2 0,2 0,1 0,5 0,4 0,3 0,2 0,8 0,6 0,4 0,3 1,2 0,9 0,6 0,5 2,1 1,5 1,0 0,8 3,3 2,3 1,7 1,3 5,2 3,7 2,6 2,1 7,2 5,1 3,6 3,0 10,3 7,3 5,2 4,2 14,5 10,2 7,2 5,9 19,6 13,9 9,8 8,0 24,8 17,5 12,4 10,1 31,0 21,9 15,5 12,6 38,2 27,0 19,1 15,6 49,6 35,0 24,8 20,2 61,9 43,8 31,0 25,3 Short circuit current in kA 10 0,1 0,1 0,2 0,3 0,5 0,7 1,2 1,6 2,3 3,2 4,4 5,5 6,9 8,5 11,1 13,9 67 SHORT TIME DUTY If a cable is intended to supply motor or equipment operating for periods of half an hour or one hour, its current rating given in table “current rating”, may be increased using the relevant correction factors given by formula: correction = factor 1,12 1-exp(-ts/T) ( ts = service time, min. T = Time constant, min.) T = 0,245 x d 1,35 (d = Overall diameter of the cable, mm.) Overall diameter of the cable, mm. Service time, min. 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 Time Critical constant, duration, min. min. 30 60 T 3x T 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,059 1,059 1,061 1,126 1,255 1,403 1,554 1,705 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,058 1,066 1,105 1,173 1,254 1,341 0,245 0,625 1,08 1,59 2,15 2,75 3,39 4,06 4,76 5,48 14,0 24,2 35,6 48,2 61,6 0,735 1,87 3,24 4,78 6,46 8,26 10,2 12,2 14,3 16,5 41,9 72,5 107 145 185 Intermittent service Correction factor for intermittent service according to the standard IEC 60092-352 The correction factor given hereby has been roughly calculated for periods of 10 min, of which 4 min are with a constant load and 6 min without load. Intermittence period = 10min. Intermittence ratio = 40%. Fi= 1-exp(-10/T) 1-exp(-4/T) 8/2010 Correction factor. TECHNICAL INFORMATION Short time duty according to the standard IEC 60092-352 0,6/1 kV +90°C marine cables. Overall diameter of the cable, mm. Correction factor. 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 1,000 1,001 1,012 1,042 1,083 1,127 1,170 1,208 1,242 1,273 1,433 1,490 1,518 1,534 1,544 8/2010 TECHNICAL INFORMATION 68 SHORT CIRCUIT FACTORS Short circuit factors for single (1) core cables Cross-section of the conductor in mm2 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Duration of the short circuit in s. 0,2 0,5 1 2 3 23,3 27,2 32,6 38,4 46,0 55,0 65,3 73,7 85,9 95,2 106,9 115,2 127,2 137,3 150,7 166,0 14,7 17,2 20,6 24,3 29,1 34,8 41,3 46,6 54,3 60,2 67,6 72,9 80,4 86,8 95,3 105,0 10,4 12,2 14,6 17,2 20,6 24,6 29,2 33,0 38,4 42,6 47,8 51,5 56,9 61,4 67,4 74,2 7,4 8,6 10,3 12,1 14,5 17,4 20,6 23,3 27,2 30,1 33,8 36,4 40,2 43,4 47,6 52,5 6,0 7,0 8,4 9,9 11,9 14,2 16,9 19,0 22,2 24,6 27,6 29,8 32,8 35,4 38,9 42,9 Short circuit factors for two (2) core cables Cross-section of the conductor in mm2 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Duration of the short circuit in s. 0,2 0,5 1 2 3 27,2 32,6 38,4 45,6 54,4 64,5 77,7 84,6 98,9 114,3 – – – – – – 17,2 20,6 24,3 28,8 34,4 40,8 49,2 53,5 62,6 72,3 – – – – – – 12,2 14,6 17,2 20,4 24,3 28,8 34,8 37,9 44,2 51,1 – – – – – – 8,6 10,3 12,1 14,4 17,2 20,4 24,6 26,8 31,3 36,1 – – – – – – 7,0 8,4 9,9 11,8 14,0 16,7 20,1 21,9 25,5 29,5 – – – – – – Short circuit factors for three (3) and four (4) core cables Short circuit factors for cables with a core no. from five (5) to thirtyseven (37) The conductor in mm2 The conductor in mm2 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Duration of the short circuit in s. 0,2 0,5 1 2 3 32,6 38,9 45,0 54,4 65,3 78,0 91,7 108,8 120,9 134,4 151,3 163,2 181,4 198,0 214,7 236,0 20,6 24,6 28,5 34,4 41,3 49,3 58,0 68,8 76,5 85,0 95,7 103,2 114,7 125,2 135,8 149,3 14,6 17,4 20,1 24,3 29,2 34,9 41,0 48,7 54,1 60,1 67,7 73,0 81,1 88,6 96,0 105,5 10,3 12,3 14,2 17,2 20,6 24,7 29,0 34,4 38,2 42,5 47,8 51,6 57,4 62,6 67,9 74,6 8,4 10,0 11,6 14,0 16,9 20,1 23,7 28,1 31,2 34,7 39,1 42,1 46,8 51,1 55,4 60,9 5x1,5 5x2,5 5x4 5x6 5x10 5x16 7x1,5 7x2,5 10x1,5 10x2,5 12x1,5 12x2,5 14x1,5 14x2,5 16x1,5 16x2,5 19x1,5 19x2,5 24x1,5 24x2,5 27x1,5 27x2,5 37x1,5 37x2,5 Duration of the short circuit in s. 0,2 0,5 1 35,0 45,3 52,2 65,3 74,2 93,3 40,8 51,0 44,5 58,3 49,0 62,8 49,0 62,8 54,4 68,0 54,4 74,2 61,2 81,6 61,2 81,6 70,0 90,7 22,1 28,7 33,0 41,3 46,9 59,0 25,8 32,3 28,2 36,9 31,0 39,7 31,0 39,7 34,4 43,0 34,4 46,9 38,7 51,6 38,7 51,6 44,2 57,4 15,6 20,3 23,4 29,2 33,2 41,7 18,3 22,8 19,9 26,1 21,9 28,1 21,9 28,1 24,3 30,4 24,3 33,2 27,4 36,5 27,4 36,5 31,3 40,6 2 3 11,1 14,3 16,5 20,6 23,5 29,5 12,9 16,1 14,1 18,4 15,5 19,9 15,5 19,9 17,2 21,5 17,2 23,5 19,4 25,8 19,4 25,8 22,1 28,7 9,0 11,7 13,5 16,9 19,2 24,1 10,5 13,2 11,5 15,1 12,6 16,2 12,6 16,2 14,0 17,6 14,0 19,2 15,8 21,1 15,8 21,1 18,1 23,4 69 VOLTAGE DROP Size 1,5 mm2 2,5 mm2 4 mm2 6 mm2 10 mm2 16 mm2 25 mm2 35 mm2 50 mm2 70 mm2 95 mm2 120 mm2 150 mm2 185 mm2 240 mm2 300 mm2 Resistance at +20°C ohm/km Resistance at +90°C ohm/km Voltage reduction mV/Am *) Resistance at +45°C ohm/km Current rating A **) Voltage reduction mV/m ***) 12,1 7,41 4,61 3,08 1,83 1,15 0,727 0,524 0,387 0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 15,4 9,45 5,88 3,93 2,33 1,47 0,927 0,668 0,493 0,342 0,246 0,195 0,158 0,1264 0,0961 0,0766 30,9 18,9 11,8 7,85 4,67 2,93 1,85 1,34 0,99 0,68 0,49 0,39 0,32 0,25 0,19 0,15 13,3 8,14 5,06 3,38 2,01 1,26 0,798 0,575 0,425 0,294 0,212 0,168 0,136 0,1088 0,0828 0,0660 23 30 40 52 72 96 127 157 196 242 293 339 389 444 522 601 0,61 0,49 0,41 0,35 0,29 0,24 0,20 0,18 0,16 0,14 0,12 0,11 0,10 0,096 0,086 0,078 TECHNICAL INFORMATION Cable types: LKM-HF, LKSM-HF, LKAM-HF, LKM-FRHF, LKSM-FRHF (Cables with class 2 conductor) Cable types: LKM-HF FLEX, LKSM-HF FLEX, LKEM-HF (Cables with class 5 conductor) 0,75mm2 1,0mm2 1,5mm2 2,5mm2 4mm2 6mm2 10mm2 16mm2 25mm2 35mm2 50mm2 70mm2 95mm2 120mm2 150mm2 185mm2 240mm2 300mm2 Resistance at +20°C ohm/km Resistance at +90°C ohm/km Voltage reduction mV/Am *) Resistance at +45°C ohm/km Current rating A **) Voltage reduction mV/m ***) 26,0 19,5 13,3 7,98 4,95 3,30 1,91 1,21 0,780 0,554 0,386 0,272 0,206 0,161 0,129 0,106 0,0801 0,0641 33,2 24,9 17,0 10,18 6,31 4,21 2,44 1,54 0,995 0,706 0,492 0,347 0,263 0,205 0,164 0,135 0,102 0,082 66,3 49,7 33,9 20,4 12,6 8,42 4,87 3,09 1,99 1,41 0,98 0,69 0,53 0,41 0,33 0,27 0,20 0,16 28,6 21,4 14,6 8,76 5,44 3,62 2,10 1,33 0,857 0,608 0,424 0,299 0,226 0,177 0,142 0,116 0,088 0,070 14 17 22 30 39 50 71 94 123 153 196 240 284 331 389 444 522 601 0,80 0,73 0,64 0,53 0,42 0,36 0,30 0,25 0,21 0,19 0,17 0,14 0,13 0,12 0,11 0,10 0,09 0,08 Cable types: LKSM-HF 250V, RFE-HF, RFE-HF(i), RFA-HF, RFA-HF(i), RFE-FRHF, RFE-FRHF(i), RFA-FRHF, RFA-FRHF(i) Size 0,5 mm2 0,75 mm2 1,5 mm2 Resistance at +20°C ohm/km Maximum conductor temperature, °C Resistance at +45°C ohm/km Voltage reduction mV/Am at +45°C Resistance at +90°C ohm/km Voltage reduction mV/Am at +90°C 40,4 26,0 12,8 90 90 90 44,4 28,6 14,1 88,7 57,1 28,1 51,5 33,2 16,3 103,0 66,3 32,6 *) at +90°C **) For continuous service (single core, ambient temperature +45°C) ***) at maximum current rating for continuous service at +45°C 8/2010 Size