Turck Networks Part Number Key

advertisement
Network I/O and Media Part Number Keys
On-Machine Modular I/O
BL67 Gateways Part Number Key
BL67 Slices Part Number Key
BL 67 - GW - EN - IP - DN -
BL 67 -
8
BL67 Bases Part Number Key
DO - 0.5A
-
P
Special Connector Options
T = Built-in 7/8-16 UN (minifast ®) tee on
CAN
open Gateway
Modular IO System
Environment
67 = On-Machine IP67
System
Discrete IO Secondary Descriptor
67 = On-Machine IP67
System
DN= DeviceNet™ Master
Gateway Type
Ethernet Type
Number of IO
GW
PG
(blank) = Modbus TCP/IP
IP = EtherNet/IP
PN = PROFINET
1
2
4
8
16
= Standard Gateway
= Programmable Gateway
Network
EN =
DPV1
DP=
DN=
CO
Ethernet
= PROFIBUS DPV1
PROFIBUS DPVO
DeviceNet
= CANopen
=
=
=
=
=
Unique Identifier
P = PNP, positive switching
N = NPN, negative switching
PD= PNP, positive switching with per port
Diagnostics
NO = Normally Open Relays
Modular IO System
Environment
Subnet Type
BL 67 - B - 1 M16 - 14 - 0.5M -
Modular IO System
P = Paired Base, (eg: in 4M12 standard pinout has
0 and 4 on first connector, P base has 0 and 1
on first connector)
Environment
VO= Power Feed base that only refreshes Output
voltage and carries input voltage from previous
segment
67 = On-Machine IP67 System
IO Descriptors
Base
Output Descriptors
0.1A = 100mA outputs
0.5A = 500mA outputs
2A = 2A outputs
R = Relay Outputs
1 Channel
2 Channels
4 Channels
8 Channels
16 Channels
Length of built-in Cordset
Number of Connectors
1
2
4
8
Analog Descriptors
I = Current
V = Voltage
PT = RTD
TC = Thermocouple
Type of IO
DI = Digital Inputs
DO = Digital Outputs
XSG = Configurable Digital Inputs or Outputs
AI = Analog Inputs
AO= Analog Outputs
RFID = Radio Frequency Identification
CNT/ENC
= High Speed Counter
SSI = SSI Encoder Interface
CVI = CANopen Valve Interface
RS232 = RS232 Serial
RS485/422 = RS485 or RS422 Serial
PF = Power Feed
VI = Available power pins are directly connected to
backplane power, not fused by slice.
B = Base
=
=
=
=
1 Connector
2 Connectors
4 Connectors
8 Connectors
Number of Pins
Type of Connectors
M8=
M12
M16
M23
RSM
picofast ® - M8x1
= eurofast ® - M12x1
= versafast ® - M16x0.75
= multifast ® - M23x1
= Male minifast ® Power connector - 7/8-16UN
(blank) = Standard Number for connector
4 = 4 Pins
8 = 8 Pins
14 = 14 Pins
19 = 19 Pins
On-Machine Flexible Block I/O
piconet I/O System Part Number Key
BL Compact Part Number Key
S DP L - 04 04 D - 1 003
BLC DN - 8 M12 L T 4AI-VI - 8DI-P
Generic Identifier
I/O Type Position #2
Refer to documentation for specifics
Flexible Block I/O Station
Network
Number of Additional Network Connections
Network
EN =
IP =
PN=
DP=
DN=
CO =
NN =
0 = Single Fieldbus connection (Non-SNNE
modules only)
DN = DeviceNet
DP = PROFIBUS DP
CO = CANopen
Modbus TCP/IP
EtherNet/IP™
PROFINET
Profibus ® DP
DeviceNet™
CANOPEN
Module used on
Piconet Fiber-Optic Network
1 = Both Input and Output Fieldbus Connection
Signal Type
Number of IO Ports
D = Discrete Signals
A = Analog Signals
S = Special Signals
1
2
4
6
8
16
Module Type
Number of Output Signals
L = Linking Module
B = Block Module
E = Extension Module
00 = No Ouputs
02 = 2 Outputs
04 = 4 Outputs
08 = 8 Outputs
Number of Input Signals
00
02
04
08
=
=
=
=
=
=
=
=
=
=
4DI-P
4DI-N
4DI-PD
8DI-P
8DI-N
8DI-PD
8XSG-PD
4DO-0.5A-P
4DO-2A-P
4DO-2A-N
4DIDO-PD
8DO-0.5A-P
8DO-0.5A-N
8DO-R-NO
CVI
2RFID-S
2RFID-A (PROFIBUS DP only)
4AI-VI
4AI4AO-VI
4AO-V
2AI2AO-VI
1 port
2 ports
4 ports
6 ports
8 ports
16 ports (only with M8 connectors)
Type of Connectors
M8 = picofast ® (8 mm)
M12 = eurofast ® (12 mm)
M16 = versafast ® (16 mm)
No Inputs
2 Inputs
4 Inputs
8 Inputs
Housing Style
I/O Type Position #1
S = Small Housing - One I/O slice
M = Medium Housing - One I/O slice
L = Large Housing - Two I/O slices
4DI-P
4DI-N
4DI-PD
8DI-P
8DI-N
8DI-PD
8XSG-PD
4DO-0.5A-P
4DO-2A-P
4DO-2A-N
4DIDO-PD
8DO-0.5A-P
8DO-0.5A-N
8DO-R-NO
CVI
2RFID-S
Auxilliary Power Connector
(blank) = No Aux Power Connector
T = Aux Power Present
2AI-I
2AI-V
2AO-I
2AO-V
2AI-PT
2AI-TC
1RS232
1RS485-422
1SSI
1CNT
2RFID-A (PROFIBUS DP only)
4AI-VI
4AI4AO-VI
4AO-V
2AI2AO-VI
2AI-I
2AI-V
2AO-I
2AO-V
2AI-PT
2AI-TC
1RS232
1RS485-422
1SSI
1CNT
On-Machine Block I/O
Ethernet, PROFIBUS ® DP AIM Station Part Number Key
DeviceNet™, AS-I ® AIM Station Part Number Key
F X EN - IOM 8 8 0001 - IP - DN
F DN P - L 04 04
G
-
- T T
-
V
Connector Material
Subnet Type
Fixed I/O Station
DN = DeviceNet Master
Ethernet Type Indicator
Diagnostic Type
MB
IP
PN
L = Standard Diagnostics; Group Diagnostics
X = Deluxe Diagnostics; Per Port Input
Diagnostics, Per Point Output Diagnostics
Network
EN = Ethernet
DP= Profibus ® DP
=
=
=
=
= Modbus TCP/IP
= EtherNet/IP™
= PROFINET
4
8
12
16
Configurable Input or Output Points
Static Input and Output Points
Input Only
Output Only
=
=
=
=
=
=
=
=
=
=
DN
ASi
Housing Style
P
L
Q
4
4 Output Points
8 Output Points
12 Output Points
16 Output Points
8 Input Points
12 Input Points
16 Input Points
20 Input Points
24 Input Points
32 Input Points
=
=
=
=
T = minifast ® Pass Through, both male and
female
M = minifast ® drop, single male
W = minifast ® drop, single male, rotated keyway
C = eurofast ® Pass Through, both male and
female
E = eurofast ® Drop, single male
= DeviceNet ® Stations
= AS-I Stations
Refer to documentation for specifics
Number of Input Points
8
12
16
20
24
32
Aux Power Connector
Network
Generic Identifier
Number of Output Points
IO Type
XSG
IOM
IM
OM
(blank) = Nickel Plated Brass
V = Stainless Steel
Fixed IO Station
8 I/O Ports/Aux power/220 mm long
8 I/O Ports/197 mm long
4 I/O Ports/148 mm long
4 I/O Ports/125 mm long
DeviceNet Connector Configuration
T = minifast ®, Pass Through, both male and female
S = minifast ®, Pass Through, both male and female,
screw terminal through back of module
M = minifast ®, Drop, single male
W = minifast ®, Drop, single male, rotated keyway
C = eurofast ®, Pass Through, both male and female
E = eurofast ®, Drop, single male
Type of IO
(blank) = non-discrete
L = NPN/PNP, Individual Open and Short-circuit
Detection
P = PNP, Individual Open and Short-circuit Detection
S = PNP, Group Short-circuit Detection, Earth Ground
Pin 5
C = Combined - PNP input and PNP Output
X = Universal - PNP Input or PNP Output
N = NPN, Group Short-circuit Detection, Earth Ground
Pin 5
E = E-Connect Safety Station
G = 0.5A Outputs
Analog Description
I = Current input for analog module
V/I = Current or Voltage input for analog module
IO Description
G = 0.5 Amp Outputs
H = 1.4 or 2.0 Amp Outputs
AI = Analog Input
Number of Inputs
00
01
02
04
08
12
16
=
=
=
=
=
=
=
0 Inputs
1 Inputs
2 Inputs
4 Inputs
8 Inputs
12 Inputs
16 Inputs
Number of Outputs
00
01
02
03
04
08
16
=
=
=
=
=
=
=
0 Outputs
1 Output
2 Outputs
3 Outputs
4 Outputs
8 Outputs
16 Outputs
In-Cabinet Modular I/O
BL20 Slices Part Number Key
BL20 Gateways Part Number Key
BL 20 -
BL20 Bases Part Number Key
BL 20 - E - 16 DO - 24VDC - 0.5A - P
- GW - EN - IP - DN
BL 20 - S 6 T - S.. Discrete I/O Secondary Descriptor
Subnet Type
Modular IO System
DN= DeviceNet Master
Environment
Ethernet Type
Environment
20 = In-Cabinet IP20 System
(Blank) =
Modbus TCP/IP
IP = EtherNet/IP™
PN= PROFINET
20 = In-Cabinet IP20 System
Economy
(blank)= Standard Gateway
(Screw or Tension Clamp, up to 72 slices)
E = Economy Gateway
(Tension Clamp Only, up to 32 slices)
Network
EN = Ethernet IP
DPV1 = PROFIBUS DPV1
DNET = DeviceNet™
CANOPEN = CANopen
Gateway Type
GW = Standard Gateway
GWBR =
Standard Gateway (DeviceNet and CANOPEN only)
PG= Programmable Gateway
P = PNP, positive switching
N = NPN, negative switching
NO = Normally Open Relays
NC = Normally Closed Relays
CO = 1 Normally Open, 1 Normally Closed
NAMUR =
NAMUR Digital Inputs
Modular I/O System
I/O Descriptor
Output Descriptors
0.5A = 500mA outputs
2A = 2A outputs
R = Relay Outputs
Number of Terminal Rows
Connection Technology
3 = 3 Rows
4 = 4 Rows
6 = 6 Rows
T = Tension Clamp
S = Screw Terminal
Number of I/O
1
2
4
8
16
32
=
=
=
=
=
=
1 Channel
2 Channel
4 Channel
8 Channel
16 Channel
32 Channel
Analog Descriptors
I(0/4…20MA) = Current
U(-10/0…+10VDC) = Voltage
U/I = Voltage or Current
PT/NI-2/3 = 2 or 3 wire RTD
THERMO-PI = Thermocouple
RFID Transceivers Part Number Key
Environment
20 = In-Cabinet IP20 System
T N LR -
XSG - E
Type of IO
S = PNP Inputs
SN= NPN/PNP Inputs
XSG = Universal PNP Input or
500 mA Output
Note: Available combinations:
SBB
= Signal, Power, Power
SBBC
= Signal, Power, Power, C-Rail Term.
Operating Voltage Rating
SBBS
= Signal, Power, Power, Signal
(blank) = 24 Volts - Direct Current
24VDC = 24 Volts - Direct Current
120/230VAC = 120 or 230 Volts - Alternating Current
SBBSBB
= Signal, Power, Power, Signal, Power, Power
SBC
= Signal, Power, C-Rail Term.
SBCS
= Signal, Power, C-Rail Term., Signal
SBCSBC
= Signal, Power, C-Rail Term., Signal, Power, C-Rail Term.
- Standard Format
RFID Tags Part Number Key
Q 80 L 400
-
T W - B S 10x1.5 - 19 -
- H1147 L /S1126
-
K
Manufacturer
Firmware Description
Manufacturer
Memory Amount
(Blank) = Part Number Specific - Refer to
documentation for
details
E = eurofast ® connector - male only
T = TURCK
(blank) = Standard Firmware
T = TURCK
Writability
Embeddability
/S1126 = Extended Firmware to
read SL1 Tags
B128
B256
K2 =
K8 =
PNP Inputs
NPN/PNP Inputs
= Universal PNP Input or 500 mA Output
Drive Interface
Number of IO Points
4 = 4 points of IO
16 = 16 points of IO
32 = 32 points of IO
S = Signal Terminal
B = Power/Signal Terminal
C = C-Rail Terminal
Connectors and Mounting
Number and Type of IO
S =
SN=
XSG
DR=
20 = In-Cabinet IP20 System
S = Single Module
B = Block Module
P = Power Module
AIM Stations Part Number Key
AS = AS-interface
DN= Devicenet ®
DP= Profibus DP
CJ = Cold Junction - For use with
Thermocouple slice
(Blank) =
Standard
E = Economy Module
RFID System - BL
Network
Environment
Type of Terminal (see note for available combinations)
In-Cabinet Block I/O
Fixed IO Station
B = Power Base that only feeds power to
the right
Type of Module
DI = Digital Inputs
DO = Digital Outputs
AI = Analog Inputs
AIH = Hart Analog Inputs
AO= Analog Outputs
AOH = Hart Analog Outputs
RFID-A =
Radio Frequency Identification
RFID-S =
Radio Frequency Identification
SWIRE =
SWIRE Master for Motor Starters
CNT = High Speed Counter
SSI = SSI Encoder Interface
RS232 =
RS232 Serial
RS485-422 = RS485 or RS422 Serial
PF = Power Feed
BR= Bus Refreshing
4
Modular IO System
Economy Modules
Type of I/O
F DN 20 - 4 S -
Unique Identifier
Number of IO Points
N = Non-Embeddable in metal
B = Embeddable in metal
Connector Orientation
(blank) = connector directly out lengthwise
of transceiverL
= connector out widthwise of transceiver
Range Identifier
(blank) = Standard Range
LR = Long Range
ER = Extended Range - Only reads SL1
tags
Connector Type
H1147 = eurofast ® embedded connector
RS4.47T = eurofast ® with embedded
cordset
4 = 4 points of IO
Barrel Material
(blank) = Nickel Plated Brass
E = Stainless Steel
Length in Meters of Embedded Cordset
Housing Style
M =
Q =
S =
CK=
Threaded Barrel
Square or Rectangular Faced
Ring
Cube
IP Rating
(blank) = IP68
WD = IP69K (Washdown)
Second Size Dimension
First Size Dimension / Ring Diameter
Second Dimension Description
(blank) = Square or Round housing
L = Length
R = Read Only
W = Read/Write
Unique Identifier
Tag Style
R =
Q =
L =
B =
WB =
C =
I =
Round
Rectangular in Housing
Label
Bolt
Wristband
Plastic Card
Raw Inlay
=
=
=
=
Stainless Steal
Steal
Delrin
Plastic
M
MF
= Embeddable in metal
= Embeddable in metal
HT
= High Temperature
MG = Magnet
For Label Tags
S = Synthetic Material
PF = Paper Face
Second Dimension
Housing Material
V
S
D
P
= 128 Bytes
= 256 Bytes
2 Kilobytes
8 Kilobytes
First Dimension
Ethernet Switches
Power Supplies
Ethernet Switches Part Number Key
Power Supplies Part Number Key
SE 20 - 84 X T - RJ 5 2 2
Ethernet Switch
Environment
(blank) = On-Machine Mountable - IP67
20 = In-Cabinet Mountable - IP20
PSU 67 - 1 1 - 24 4 0 /M
Connector Material
Power Supply Unit
2 = Nylon
4 = Nickel Plated Brass
PSU
Connector Material
Housing Material
Environment
2 = Nylon
67 = On Machine Mountable - IP67
0 = Nickel Plated
Brass
Number of Pins
Number of Ports
Number of Input Connectors
Output Current Rating
84 = 8 pin
44 = 4-pin D-coded
5 = 5 Ports
9 = 9 Ports
1 = 1 Input Connector
2 = 2 Amps
4 = 4 Amps
8 = 8 Amps
Type of Switch
Connector Type
X = Unmanaged
M = Managed
RJ = RJ45
E = eurofast ®
Number of Output Connectors
1 = 1 Output Connector
2 = 2 Output Connectors
Output Voltage
24 = 24 VDC
Power Connection
(blank) = 5 pin minifast ®
4 = 4 pin minifast ®
T = Terminal Strip
minifast ® Network Media
picofast ® Network Media
minifast ® Network Cordsets Part Number Key
W K M
minifast ® Network Receptacle Part Number Key
57x - *M
7/8-16UN (minifast)
R K F
Length in Meters
R = Straight
W = Right Angle
Network
25 =
39 =
43/63
45 =
47 =
48 =
49 =
53 =
57 =
58 =
66 =
Gender
K = Female Connector, Female Threads
S = Male Connector, Male Threads
Coupling Nut Material
(Blank) = Nylon
M = Nickel Plated Brass
V = Stainless Steel
AS-interface ®
Data Highway Plus (Blue Hose ®)
= CC-Link
PROFIBUS ®-DP
Genius I/O
PROFIBUS ®-PA
FOUNDATION™ fieldbus
SDS
DeviceNet™
Seriplex™
Interbus-S
V
picofast ® Network Cordsets Part Number Key
57x *M /NPT
P K G Z
7/8-16UN (minifast) Receptacle
Connection Thread
M8x1 (picofast)
Gender
(Blank) = ½-14 NPSM Threads
/NPT = ½-14 NPT Threads
/14.5 = ½-14 NPT Full Length Threads
/14.75 = ¾-14 NPT Full Length Threads
/M20 = M20 Threads
Connector Configuration
K = Female Connector, Female Threads
S = Male Connector, Male Threads
57x - *M
Length in Meters
K = Female Connector
S = Male Connector
Network
57 = DeviceNet
Length in Meters
Designator for Receptacle
Connector Configuration
G = Straight
W = Right Angle
Network
Mounting Style
25 =
39 =
43/63
45 =
47 =
48 =
49 =
53 =
57 =
58 =
66 =
(Blank) = Front Mount
P = Back Panel Mount
Housing Material
(Blank) = Nickel Plated Brass
K = Nylon
V = Stainless Steel
Connection Type
(Blank) = Leads or PCB Pins
L = Solder Cup
AS-interface ®
Data Highway Plus (Blue Hose ®)
= CC-Link
PROFIBUS ®-DP
Genius I/O
PROFIBUS ®-PA
FOUNDATION™ fieldbus
SDS
DeviceNet™
Seriplex™
Interbus-S
Locking Method
(blank) = male snap Lock (No Locking Sleeve)
Z = female snap Lock (Locking Sleeve)
M = M8x1 Threaded Coupling Nut
F = fixed thread (3-pin male only)
V = Stainless Steel
eurofast ® Network Media
eurofast ® Network Receptacles Part Number Key
eurofast ® Network Cordsets Part Number Key
R S C W V
F S FD
57x *M
M12x1 (eurofast) Cordset
V
57x - *M
M12x1 (eurofast) Receptacle
Length in Meters
Length in Meters
R = Straight
W = Right Angle
Gender
Network
K = Female Connector, Female Threads
S = Male Connector, Male Threads
25 = AS-interface ®
C
G
S
T
=
=
=
=
42 = PROFINET
44 = Ethernet (4-pin)
45 = PROFIBUS ®-DP
47 = Genius I/O
Keying Options
(Blank) = Standard Key
D = D-coding Key
W = Reverse Key
Housing Style
(Blank) = Front Mount
FD = Standard Back Panel Mount
FDE = Back Panel Mount, Large Body
S = Shielded to Receptacle Housing
SDE = Shielded Back Panel Mount, Large Body
43/63 = CC-Link
Large Plug Body
Robust Large Plug Body
Shielded to Coupling Nut
Small Plug Body
25 =
39 =
42 =
43/63
44 =
45 =
47 =
48 =
49 =
53 =
57 =
58 =
66 =
84 =
K = Female Connector, Female Threads
S = Male Connector, Male Threads
39 = Data Highway Plus (Blue Hose ®)
Plug Body
Network
Gender
48 = PROFIBUS ®-PA
Keying Options
49 = FOUNDATION™ fieldbus
(Blank) = Standard Key
D = D-coding Key
W = Reverse Key
53 = SDS
57 = DeviceNet™
58 = Seriplex™
AS-interface®
Data Highway Plus (Blue Hose®)
PROFINET
= CC-Link
Ethernet (4-pin)
PROFIBUS®-DP
Genius I/O
PROFIBUS®-PA
FOUNDATION™ fieldbus
SDS
DeviceNet™
Seriplex™
Interbus-S
Ethernet (8-pin)
Coupling Nut Material
66 = Interbus-S
Coupling Nut Material
(Blank) = Nickel Plated Brass
V = Stainless Steel
84 = Ethernet (8-pin)
(Blank) = Nickel Plated Brass
K = Nylon
U = PVDF
V = Stainless Steel
RJ Network Media
RJ Network Cordsets Part Number Key
W RJ45 E S F
44x - *M
Connector Configuration
Length in Meters
(blank) = Straight Connector
W = Right Angle Connector
Connection Style
Network
RJ45 = RJ45 Connector, 8 pins - 8 Connections
RJ11 = RJ11 Connector, 6 pins - 4 Connections
RJ25 = RJ25 Connector, 6 pins - 6 Connections
42 = PROFINET
44 = Ethernet (4-pin)
84 = Ethernet (8-pin)
Right Angle Connection Style
Gender
E = standards for external tab. Tab is on the
outside away from the cable
I = Stands for Internal tab. The tab is to the
inside. Towards the cable.
(Blank) = Male
F
= Female
Shielding
(blank) = Unshielded
S = Shielded
Network Conduit Adapters
Network Conduit Adapter Part Number Key
BCA
49 SC -
Designator for Conduit Adapter
=
=
=
=
=
=
Designator for Conduit Adapter with I/O
Number of Outputs
Number of Inputs
Network
AS-interface
Ethernet (4-pin)
PROFIBUS-PA
FOUNDATION fieldbus
DeviceNet
Ethernet (8pin)
Housing
ASI
DN
2 = Nylon
= AS-interface
= DeviceNet
Type of I/O
(blank) = Inputs on same connector as Outputs
S = PNP, Group Input Short-circuit Detection, Earth Ground Pin 5
C = Combined -Inputs on different connector than outputs
G = 0.5A Outputs
Number of Ports
1 = 1 port
2 = 2 ports
(blank)= None
SC
= Short-circuit
Connector Type
E = eurofast ®
M = minifast ®
Special Modifier
/40
BCS - ASI - CSG 2 2
3 = Stainless Steel
4 = Nickel-Plated Brass
Protection
/P
/PS
- M 1 2 3
Connector Material
Network
25
44
48
49
57
84
Network Conduit Adapter with I/O Part Number Key
= Stainless Steel Cover Screws
= Stainless Steel Cover Screws and Special Gasket for PVC Coated
Conduit Bodies
= DeviceNet 4-pin Aux. Power
Network Junctions
In-Cabinet Network Junction Part Number Key
On-Machine Network Junctions Part Number Key
JB BS - 57 SC
JR BS - 57 SC -
- M 6 3 3 M
12 R
Type of Housing
picofast Connector Type
Type of Network Junction
Mounting Method
JB = Junction Box
JT = Junction Tee
M = Threads
S = Snap
JR = Junction Rail
(blank) = Standard 35mm DIN Rail
R = Extended Rail Mount
Connector Material
Network
Number of Ports
1 = Nickel-Plated Brass
3 = Stainless Steel
25 = AS-interface®
48 = PROFIBUS®-PA
49 = FOUNDATION™ fieldbus
57 = DeviceNet™
4
6
8
10
12
Network
25 = AS-interface ®
43/63 = CC-Link
45 = PROFIBUS ®-DP
48 = PROFIBUS ®-PA
49 = FOUNDATION™ fieldbus
53 = SDS
57 = DeviceNet™
Housing
0 =
1 =
2 =
3 =
4 =
11/12
Aluminum (DeviceNet only)
Aluminum (JBBS only)
Fiberglass (JBBS only)
Polyurethane (JTBS only)
Hytrel (JTBS only)
= Nylon (DeviceNet only)
Number of Ports
Protection
(blank) = None
SC= Short-Circuit
VM = Voltage Monitoring
4 = 4 ports
6 = 6 ports
8 = 8 ports
Connector Type
DeviceNet Bus Connector Type
(Blank) =
minifast Bus Connectors
FS = Male M12 Bus Connectors
FS/VM =
Male M12 Bus Connector with Voltage Monitoring
E = eurofast
M = minifast
P = picofast
=
=
=
=
=
4 ports
6 ports
8 ports
10 ports
12 ports
Protection
(blank) = None
SC
= Short-Circuit
VM = Voltage-Monitoring
Unique Identifier
TR = Embedded Terminating Resistor
Download