Electric Infrared Heating Controls Pre-Wired Contactor Panels • Factory pre-wired for quick installation, • Step-down transformer and secondary with the following optional equipment: fusing for 24V or 120V control circuit. Snow & Ice Detector (APS-3C) • 3-Phase load rated. Single & Two-Stage Thermostats • Fuses are NOT included. Two-stage thermostats require a • NEMA 1 Enclosures. minimum 2-contactors. • Max 50-Amp branch circuit fusing. Note: Contact factory for 3R, 4, 4X, & NEMA 12 “special” built models. IMPORTANT FUSING INFORMATION Fuses are NOT included since panels can be used with various infrared heat sources. Quartz Lamp Heat Sources: Use FRS-600V (or equal) “Time Delay” fuses; Class RK-5. Quartz Tube & metal Sheath Heat Sources: Use KTS-R 600V (or equal) “Fast Acting” fuses; Class RK-1. Fuse circuits as close to calculated load as possible. Circuits less than 35 Amps will require the use of fuse reducers. FPC2120 Manufactured in U.S.A. 120-V Control System UPC# 686334 4459902 4460002 4460102 4460202 4460302 4460402 4460502 4460602 4460702 4460802 4460902 4461002 4461102 4461202 4461302 4461402 Model FPC8110 FPC2110 FPC7110 FPC4110 FPC8120 FPC2120 FPC7120 FPC4120 FPC8140 FPC2140 FPC7140 FPC4140 FPC8160 FPC2160 FPC7160 FPC4160 24-V Control System UPC# 686334 4864302 4864402 4864502 4864602 4864702 4864802 4864902 4865002 4865102 4865202 4865302 4865402 4865502 4865602 4865702 4865802 Cabinet Size (In.) Max. Amps Model FPC8210 FPC2210 FPC7210 FPC4210 FPC8220 FPC2220 FPC7220 FPC4220 FPC8240 FPC2240 FPC7240 FPC4240 FPC8260 FPC2260 FPC7260 FPC4260 50 100 200 300 Volts Depth Width Height WT. (Lbs.) 6.75 16 24 52 6.75 16 24 70 6.75 24 30 88 6.75 30 36 106 208 240 277/480 480 208 240 277/480 480 208 240 277/480 480 208 240 277/480 480 LIST 1752 1891 1752 2142 2336 2142 3143 3337 3143 3865 4061 3865 Portable Electric Infrared Heat Panels Features • Portable panels are built to withstand rigors of industrial and heavy-commercial applications, such as auto collision repair shops. • 20 Gauge Steel frame, base, and housing construction. • 3” Steel casters for high stability and ease of mobility • Gold anodized Aluminum reflectors and end caps allow 10% faster cure time than polished Aluminum reflectors, especially in paint and dust-laden atmospheres. • Elements achieve full temperature in less than 2 minutes • Fused disconnect switches are installed on the back of each unit. • Units are positioned with adjustable hinges allowing the user to use direct heat more precisely to the target area. • Gentle but effective medium-wave radiant heat can quickly boost, flash-off, or cure a variety of finishes, and lessens the chance of blistering and/or overheating the coating. • Medium-wave infrared heating elements are also effective for flash-off of water-based clear coatings being mandated by environmental agencies in many states. HP-5-QT HP-11-QT General Curing Guidelines Solvent Based Water Based Two Component Water Based Acrylic enamel & Urethane Clear Coat & Primer Primer Primer Clear Coat Polyurethane Clear Coat High Solids Top Coat Curing Time 3-5 mins 3-6 mins 8-20 mins 3-10 mins 12-30 mins 10-30 mins Note: Curing times will vary depending on material and shop conditions. This chart is based on distances of 18-24” away from the target area. Material Type Standard Models UPC# 686334 884129 884136 884143 Model HP-5-QT HP-6-QT HP-11-QT WATTS VOLTS AMPS 4,800 6,400 11,200 240 20 26.7 46.7 Dimension (In.) HEAT CABLE SOURCES TYPE (20’) Width Height 4 44-5/8 12-3 SO 56-1/2 4 66-5/8 7 6-3 SO 89-1/2 Heated Area (In.) Wt. LIST Width Height 40 116 2725 44 141 3150 61 77 225 5800 75