TIME DELAY / CLASS J FUSES

advertisement
SMARTSPOT INDICATOR AMP-TRAP 2000*
SHsawmurt
TIME DELAY / CLASS J FUSES
AJT
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1
AJT1
AJT1-1/4
AJT1-1/2
AJT1-6/10
AJT1-8/10
AJT2
AJT2-1/4
AJT2-1/2
AJT2-8/10
AJT3
AJT3-2/10
AJT3-1/2
AJT4
4-1/2
AJT4-1/2
AJT5
AJT5-6/10
AJT6
AJT6-1/4
AJT7
AJT8
AJT9
AJT10
AJT12
AJT15
AJT1 7-1/2
AJT20
25
30
35
40
45
50
60
70
AJT25
AJT30
AJT35
AJT40
AJT45
AJT50
AJT60
AJT70
AJT80
AJT90
AJT1 00
AJT110
125
AJT125
AJT150
AJT175
AJT200
AJT225
AJT250
AJT300
AJT350
AJT400
AJT450
AJT500
AJT600
1-1/4
1-1/2
1-6/10
1-8/10
2
2-1/4
2-1/2
2-8/10
3
3-2/10
3-1/2
4
5
5-6/10
6
6-1/4
7
8
9
10
12
15
17-1/2
20
80
90
100
110
150
175
200
225
250
300
350
400
450
500
600
Recommended Fuse Blocks
With Box Connectors tor
Amp-trap Class J Fuses
Fuse
Ampere
Rating
Catalog Number
0-30
31-60
61-100
101-200
201-400
401-600
600V OR LESS
1Pole
3 pole
US3J1I
US6J1I
61036J
62001 J
64031 J
663 U
US3J3I
US6J3I
61038J
62003J
64033J
6633J
A variety of pole configurations and termination
provisions is available.
Note: Indicator Not availible (1-7a)
H°h1
|
M
(-
1-60A
-E-jj
B—•)
70-600A
A
AMPERE
B
In.
mm
In.
mm
1-30
2-1/4
13/16
1-1/16
31-60
2-3/8
61-100
4-5/8
57
60
117
101-200
5-3/4
146
1-5/8
201-400
7-1/8
181
2-1/8
21
27
27
41
54
401-600
8
203
2-1/2
64
1-1/16
D
C
RATING
In.
mm
F
E
In.
mm
1-3/8
2-1/8
1/8
3.2
3/4
3/16
4.8
1-1/8
1/4
6.3
1-5/8
19
29
41
3/8
9.5
2
51
In.
1
1-7/8
mm
-
In.
25
35
48
54
G
H
mm
-
In.
mm
-
In.
mm
-
3-5/8
92
3/8
10
9/32
4-3/8
111
3/8
9/32
7
7
5-1/4
133
152
17/32
10
14
13/32
11/16
18
17/32
6
Optional Indicator/Microswitch Mount (El) dimensions:
A
^
iUt>
1 .2«
(31 .«)
J
•^—
N
Note:
Fuses with the El option will receive
the AOS-S or AOS-Q Add-On-Switch
th
r AOS^S 1
1
1
1
1 El
1
.67
(17.0)
n
—M_3~
-Q
L
J
CATALOG NUMBER
A
AJT(70-100)-EI
2.80
(71.0)
AJT(110-200)-EI
3.22
(81.8)
AJT(225-400)-EI
3.24
(82.2)
AJT(450-600)-EI
3.61
(91.8)
70—t
( 1 7 8)
Q.
-£Q—
A3
10
13
Shawmut
US3J & US6J 600 VOLT / ULTRASAFE™ FUSE HOLDERS
Catalog Numbers & Descriptions - For use with 30A Class J Fuses
CATALOG NO.
DESCRIPTION
US3J1
US3J2
US3J3
US3J1I
US3J2I
US3J3I
US3JN
US3J2PAK
US3J3PAK
US3J4PAK
1 Pole
2 Pole
3 Pole
1 Pole with Indicator
2 Pole with Indicators
3 Pole with Indicators
1 Pole - Neutral
2 Pole Assembling Kit
3 Pole Assembling Kit
4 Pole Assembling Kit
Catalog Numbers & Descriptions - For use with 60A Class J Fuses
CATALOG NO.
DESCRIPTION
US6J1
US6J2
US6J3
US6J1I
US6J2I
US6J3I
US6JN
US6J2PAK
US6J3PAK
US6J4PAK
1 Pole
2 Pole
3 Pole
1 Pole with Indicator
2 Pole with Indicators
3 Pole with Indicators
1 Pole - Neutral
2 Pole Assembling Kit
3 Pole Assembling Kit
4 Pole Assembling Kit
Dimensions
US6J
US3J
DIMENSION
mm
In
mm
In
A
B
C
D
E
F
G
H
J
80
106
6.5
56
114
3
32.5
65
975
3.15
4.17
0.26
2.20
4.49
0.12
1.28
2.56
3.84
89
115
6.5
62
122
3
40
80
120
3.50
4.53
0.26
2.44
4.80
012
1.57
3.15
4.72
Terminal screws: Phillips/slot head
Suggested screw torque: 30A 35 in-ibs.
60A - 45 in-lbs.
Connector type: Pressure plate
Wire range: #2 to #14 (solid/stranded Cu)
Load-break disconnect: No
H5
SMARTSPOT INDICATOR AMP-TRAP 2000'
AJT
SHawmut
TIME DELAY / CLASS J
SMARTSPOT™ WITH MAXIMUM CIRCUIT
PROTECTION
Amp-trap 2000® SmartSpot™ AJT fuses now
provide a visual open fuse indicator. With advanced
material technology added to the existing product
line the AJT fuse provides EC Type "2" (No Damage)
protection to main, feeder, and branch circuits, for all
types of loads — yet, they require only half the
mounting space needed for 600VAC Class RK fuses.
AJT's time delay characteristics for handling harmless in-rush currents, its current limiting ability (the
most current limiting UL fuse class!), and wide range
of ratings (from 1 to 600 Amperes) — give excellent
protection for all your applications.
Features/Benefits
HIGHLIGHTS:
APPLICATIONS:
i Smart Spot Indicator
Time Delay
> Highly Current Limiting
DC Ratings
Optional Mechanical
Indicator
(70 to 600A fuses)
>>
>
>
Motor Circuits
Mains
Feeders
Branch Circuits
Lighting, Heating
& General Loads
Transformers
Control Panels
> Circuit Breaker Back-up
> Bus Duct
Load Centers
Solid State SmartSpot Indicator
> Time delay for motor starting and transformer inrush
SOOkA interrupting rating - self-certified,
UL witnessed tests
Extremely current limiting for low peak let-thru current
Most current limiting UL class fuse
Small footprint requires less mounting space and
allows smaller, more economical fuse blocks
Easy 2-to-1 selectivity for prevention of nuisance
shutdowns
Unique Class J dimensions prevent replacement errors
High-visibility orange label gives instant recognition
> Metal-embossed date and catalog number for
traceability and lasting identification
> Fiberglass body provides dimensional stability in harsh
industrial settings
High-grade silica filler ensures fast arc quenching
Optional El Indicator/Switch mount for AJT70 to
600 open fuse indication
Ratings
AC: 1 to 600A
600VAC, 200kA I.R.
(self certified for
600VAC, SOOkA I.R.,
UL witnessed)
DC: 1 to 600A
500VDC, 100kAI.R.
Approvals
AJT (1-600):
> UL Listed to
Standard 248-8
> DC Listed to UL
Standard 198L
> CSA Certified to
Standard C22.2
No. 248.8
IEC 269-2-1
AJT (70-600) El:
UL Component
Recognized
DC Tested to UL
Standard 198L
(§5U
A2
Download