Main Switches catalogue 15 Main switches & isolators MCCBs, load break switches & isolating switches This section includes moulded case circuit breakers and load break switches which are utilised for the switching, protection and distribution of low voltage installations. MCCBs characteristics C.4 MCCBs & accessories selection guide C.6 MCCBs x160 C.10 MCCBs x250 C.12 MCCBs h250 C.14 MCCBs h630 C.16 MCCBs h1000 C.19 MCCBs h1600 C.21 Load break switches C.23 Load break switches characteristics C.25 Earth leakage relays and toroids C.26 Ph 1300 850 253 | customerservice@hagerelectro.com.au | Fx 1300 424 372 Main Switches & Isolators C.2 Expert tips - MCCBs 16A to 1600A Easy mounting and safety The new range of MCCBs provide safe and easy solutions for low voltage electrical circuits protection. The state of the art circuit breakers offer both designers and installers a wide range of range perfectly meets features and benefits. With special attention being given to ergonomics, the reliability requirements for main incoming devices in commercial premises: strength, reliability, efficient protection and standards compliant selection. The advantages for you: Technical data: • Easy to install • Comply with IEC 60947-2 • Quick, easy and safe mounting of accessories • 6 frame sizes: x160, x250, h250, h630, h1000, h1600 • Wide range of rated current ratings and breaking capacities • Breaking capacity: 25, 40, 50, 70kA • Range of termination accessories • Thermal magnetic and electronic trip units • DIN rail profile up to 250A • 1 pole to 4 poles • Current limiting type • Complete range of accessories • International certification and approvals C.2 Expert tips 1 2 3 4 Design by Hager In harmony with Hager enclosures and modular products. Electronic trip unit (LSI) Provides total selectivity along with generator protection. Breaking capacity 25 to 70kA, Icu 415V AC, covers all applications. Easy auxiliary mounting Easy opening of secondary cover, clip-in type auxiliaries. 5 6 7 8 Visibility of auxiliaries A clear window indicates the type of auxiliary mounted in the breaker. Integrated padlocking Provides a convenient solution for maintenance. Full accessory range Rotary handles, padlocks, motor operators, terminal covers... Flexible connection Collar terminals, front and rear connections, straight connections, spreaders... C.3 MCCBs - characteristics Product Reference Number of poles [No.] Electrical characteristics Rated current In [A] Current rated range [A] Rated service voltage, (AC) Ue [V] Frequencyf [Hz] Rated insulation voltage Ui [V] Rated impulse withstand voltage Uimp [kV] Rated ultimate short-circuit breaking capacity, (Icu) (AC) 50-60 Hz 220/230 V Icu [kA] x160 TM MCCB HHA 3-4 35 85 85 Rated HNA 160 16-160 220-440 50/60 690 8 x250 TM MCCB HNB 3-4 250 100-250 220-440 50/60 800 8 (AC) 50-60 Hz 380/415 V Icu (AC) 50-60 Hz 480/500/525 V Icu (AC) 50-60 Hz 660/690 V Icu (DC) 250 V - 2 poles in series Icu service short-circuit breaking capacity, (Ics) (AC) 50-60 Hz 220/230 V Ics [kA] [kA] [kA] [kA] 25 10 40 10 40 9 [kA] 25 40 40 (AC) 50-60 Hz 380/415 V Ics (AC) 50-60 Hz 480/500/525 V Ics (AC) 50-60 Hz 660/690 V Ics (DC) 250 V - 2 poles in series Ics Rated short-circuit making capacity Icm Rated short-time withstand current for 1s Icw Category of use (EN 60947-2) Calibration temperature Derating40°C 50°C 55°C 60°C 65°C Suitability for isolation Electric endurance in number of cycles Mechanical endurance in number of operations Operating temperature Storage temperature Power loss (at In for 3P) Reference standard Releases: switch Releases: TM (thermomagnetic) T fixed, M fixed T adjustable, M fixed T adjustable, M adjustable Thermal adjustment value Magnetic adjustment value [kA] [kA] [kA] [kA] [kA] [kA] 20 20 20 Releases: LSI (electronic) Long delay Short delay - 5 A 50°C 100% 100% 94% 91% 88% ok 10000 20000 -25 to +70°C -35 to +70°C 60 IEC 60947-2 ok ok ok 0,63 to 0.8 to 1 x In 6-8-10-13 x In (200A) 5-7-9-11 In (250A) - Time delay Terminations Standard terminal type Maximum terminal capacity Terminal width Terminal shields Cage terminal Extended connections Rear connections Dimensions Height mm Width 3P mm 4Pmm Depth mm Weight 3P kg 4Pkg - - cage 95 mm2 ok integrated ok no lugs 185 mm2 (cage) 25 ok ok ok ok 130 75 100 68 0,715 0,95 165 105 140 68 1,3 1,6 C.4 [W] mm 5 5 A 50°C 100% 100% 95% 93% 90% ok 10000 20000 -25 to +70°C -35 to +70°C 39 IEC 60947-2 ok ok ok 0,63 to 0.8 to 1 x In - h400 TM MCCB HND 3-4 h630 LSI MCCB HND HED 3-4 h1000 LSI MCCB HNE HEE 3-4 h1600 LSI MCCB HNF HEF 3-4 250 40-125-250 220-690 50/60 800 8 400 250-400 220-690 50/60 800 8 630 250-630 220-690 50/60 800 8 1000 800-1000 220-690 50/60 800 8 1600 1250-1600 220-690 50/60 800 8 85 100 85 85 100 50 25 7,5 - 70 45 20 - 50 30 20 40 50 30 20 70 30 20 85 100 85 85 85 25 10 7,5 B 40°C 100% 95% 90% 80% 80% ok 10000 30000 -25 to +70°C -35 to +70°C 75 IEC 60947-2 - 70 45 15 - 50 30 15 40 A 50°C 100% 100% 95% 92% 89% ok 4500 15000 -25 to +70°C -35 to +70°C 75 IEC 60947-2 ok ok 0,63 to 0.8 to 1 x In 6-8-10-12 x In 50 30 15 50 30 15 0,4 to 1 x Ir 2,5 to 10 x Ir - 100 100 100 70 30 20 - 50 45 25 - 70 65 45 - 75 75 B (400A) - A (630A) 40°C 100% 100% 95% 90% 80% ok 4500 15000 -25 to +70°C -35 to +70°C 150 IEC 60947-2 - 85 (800A) 100 (800A) 75 (1000A) 75 (1000A) 50 50 30 30 20 20 B (800A) - A (1000A) 40°C 100% 100% 95% 90% 80% ok 4500 15000 -25 to +70°C -35 to +70°C 150 IEC 60947-2 - 50 45 25 B 40°C 100% 100% 95% 90% 80% ok 4500 15000 -25 to +70°C -35 to +70°C 170 IEC 60947-2 - 50 50 34 - ok 0,4 2,5 2,5 0,1 ok 0,4 to 1 x In 2,5 to 10 x Ir - ok 0,4 2,5 2,5 0,1 0,1 - 0,2s lugs 120 mm2 (cage) 25 ok ok ok ok lugs 240 mm2 (cage) 30 ok ok ok ok lugs 30 ok integrated ok lugs 45 ok integrated ok lugs 45 ok integrated ok 165 105 140 97 2,5 3,3 260 140 185 97 4,2 5,6 260 140 185 97 4,3 5,7 273/433 210 280 99,5 11 14,8 370/570 210 280 140 27 31 to 1 x Ir to 10 x Ir (400A) to 8 x Ir (630A) - 0,2s 85 (800A) 75 (1000A) 50 30 20 - to 1 x Ir to 10 x Ir (800A) to 8 x Ir (1000A) - 0,2s Main Switches & Isolators h250 LSI MCCB HNC HEC 3-4 0,1 - 0,2s C.5 MCCBs & accessory selection guide MCCB’s Terminal connectors HHA125U Frame Trip Unit Pole 3 X160 TM 4 3 x250 4 Frame x160 x250 C.6 HNB160U In (A) 25 kA 40 kA 25 40 63 80 100 125 160 25 40 63 80 100 125 160 160 200 250 160 200 250 HHA025U HHA040U HHA063U HHA080U HHA100U HHA125U HHA160U HHA026U HHA041U HHA064U HHA081U HHA101U HHA126U HHA161U - HNA025U HNA040U HNA063U HNA080U HNA100U HNA125U HNA160U HNA026U HNA041U HNA064U HNA081U HNA101U HNA126U HNA161U HNB160U HNB200U HNB250U HNB161U HNB201U HNB251U HYB031H HYA015H Terminal connectors Collar Straight Spreader Rear HYA005H HYA013H HYA014H - HYA006H HYA013H HYA015H - HYB001H HYB010H HYB011H HYB031H HYB002H HYB010H HYB012H HYB032H Shunt Trips - SH Under Voltage - UV Motor Operator Auxilliary Contact (1C/O) HXA004H HXA014H HXB040H HXA021H Operating Voltage Shunt Trips - SH Under Voltage - UV Motor Operator Auxilliary Contact (1C/O) AUX, AX Alarm, AL (1NO + 1NC) (1NO +1NC) 24V DC 48V DC HXA001H HXA002H HXA011H - - 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 48V DC 100 - 120V AC 230 - 240V AC 200 - 240V AC 380 - 450V AC HXA003H HXA004H HXA005H HXA001H HXA002H HXA003H HXA004H HXA005H HXA013H HXA014H HXA015H HXA011H HXA013H HXA014H HXA015H HXB040H HXB042H - HXA024H HXA021H HXA024H HXA021H HXA024H Interlock Phase Barrier DIN rail adaptor Rotary Handle Padlock HXB065H HYA019H HYA033H HXA031H HXA039H Interlock Phase Barrier DIN rail adaptor Rotary Handle Direct Extended Padlock HYA027H HYB022H Terminal covers Collar Straight Spreader Rear HYA027H HYA021H HYA023H - - HYA019H HYA033H HXA030H HXA031H HXA039H HYA028H HYA022H HYA024H - - HYA019H HYA033H HXA030H HXA031H HXA039H HYB027H HYB021H HYB023H HYB025H HXB065H HYB019H - HXB030H HXB031H HXA039H HYB028H HYB022H HYB024H HYB026H HXB065H HYB019H - HXB030H HXB031H HXA039H C.7 Main Switches & Isolators Terminal covers MCCBs & accessory selection guide MCCB’s Terminal connectors HEC250H Frame Trip Unit Pole 3 h250 4 3 h630 LSI 4 3 h1000 4 3 h1600 4 Frame h250 h630 C.8 HNE970H In (A) 50 kA 70 kA 40 125 250 40 125 250 400 630 400 630 800 1000 800 1000 1250 1600 1250 1600 HNC040H HNC125H HNC250H HNC041H HNC126H HNC251H HND400H HND630H HND401H HND631H HNE800H HNE970H HNE801H HNE971H HNF980H HNF990H HNF981H HNF991H HEC040H HEC125H HEC250H HEC041H HEC126H HEC251H HED400H HED630H HED401H HED631H HEE800H HEE970H HEE801H HEE971H HEF980H HEF990H HEF981H HEF991H HYD015H HYD033H Terminal connectors Collar Straight Spreader Rear HYC003H HYC010H HYC011H HYC031H HYC004H HYC010H HYC012H HYC032H HYD003H HYD007H HYD004H HYD008H HYD010H HYD013H HYD010H HYD013H HYD011H HYD014H HYD012H HYD015H - - - - - - HYD031H HYD033H HYD032H HYD034H HYE031H HYE033H HYE032H HYE034H - - - - - - - - Shunt Trips - SH Under Voltage - UV Motor Operator Auxilliary Contact (1C/O) HXC004H HXC014H HXD042H HXC021H Operating Voltage Shunt Trips SH Under Voltage - UV Motor Operator Auxilliary Contact (1C/O) AUX, AX Alarm, AL (1NO + 1NC) (1NO +1NC) 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC HXC001H HXC002H HXC003H HXC004H HXC005H HXC001H HXC002H HXC003H HXC004H HXC005H HXC011H HXC013H HXC014H HXC015H HXC011H HXC013H HXC014H HXC015H HXC040H HXC042H HXD040H HXD040H HXD042H HXD042H - HXC024H HXC021H HXC024H HXC021H HXA024H Interlock Interphase Barrier Rotary handles Padlock HXC065H HYC019H HXD030H HXC039H Interlock Interphase Barrier Rotary handles Direct Extended Padlock HYD022H HYD023H Terminal covers Collar Straight Spreader Rear HYC027H HYC021H - HYC025H HXC065H HYC019H HXC030H HXC031H HXC039H HYC028H HYC022H - HYC026H HXC065H HYC019H HXC030H HXC031H HXC039H HYD027H HYD021H HYD023H HYD025H HXD065H HYD019H HXD030H HXD031H HXD039H HYD028H HYD022H HYD024H HYD026H HXD065H HYD019H HXD030H HXD031H HXD039H - HYE021H - HYE025H HXE065H - HXE030H HXE031H HXD039H - HYE022H - HYE026H HXE065H - HXE030H HXE031H HXD039H - - - - - HXF030H HXF031H HXF039H - - - - - HXF030H HXF031H HXF039H Frame h1000 h1600 Shunt Trips - SH Under Voltage - UV Motor Operator Auxilliary Contact (1C/O) HXC004H HXE014H HXF040H HXC012H Operating Voltage Shunt Trips SH Under Voltage - UV Motor Operator Auxilliary Contact (1C/O) AUX, AX Alarm, AL (1NO + 1NC) (1NO +1NC) 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC HXC001H HXC002H HXC003H HXC004H HXC005H HXC001H HXC002H HXC003H HXC004H HXC005H HXE011H HXE013H HXE014H HXE015H HXE011H HXE013H HXE014H HXE015H HXE040H HXE040H HXE042H HXE042H HXF040H HXF042H - HXC024H HXC021H HXC024H HXC021H HXC024H C.9 Main Switches & Isolators Terminal covers MCCBs x160 Moulded case circuit breakers x160 - Thermal magnetic trip unit, 2 versions: - Z version: fixed thermal and fixed magnetic - U version: adjustable thermal and fixed magnetic - 1P, 2P, 3P & 4P - Mechanical test button, sealable settings, integrated padlocking handle Ø4mm. Connection capacity: -95mm2 rigid cables -70mm2 flexible cables - Comply with IEC60947-2. Technical information: - Visit our website at www.hagerelectro.com.au *Please check availability with your local Hager sales office at time of order MCCBs x160 25kA Description - Breaking capacity Ics: 20kA (400/415V AC) - Fixed thermal 1 x In - Fixed magnetic > 10 x In HHA125U - Adjustable thermal 0.63 - 0.8 - 1 x In - Fixed magnetic > 10 x In HHA161U In 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A 25A 40A 63A 80A 100A 125A 160A Cat ref. Cat ref. Cat ref. 1P 3P 4P* HHA014Z HHA018Z HHA023Z HHA030Z HHA038Z HHA048Z HHA061Z HHA078Z HHA098Z HHA123Z - HHA025U HHA040U HHA063U HHA080U HHA100U HHA125U HHA160U HHA026U HHA041U HHA064U HHA081U HHA101U HHA126U HHA161U Cat ref. Cat ref. MCCBs x160 40kA Description - Breaking capacity Ics: 20kA (400/415V AC) - Adjustable thermal 0.63 - 0.8 - 1 x In - Fixed magnetic > 10 x In HNA125U C.10 In 25A 40A 63A 80A 100A 125A 160A 3P 4P* HNA025U HNA040U HNA063U HNA080U HNA100U HNA125U HNA160U HNA026U HNA041U HNA064U HNA081U HNA101U HNA126U HNA161U MCCBs x160 - accessories Coil connection - Connection capacity: 0.75mm flexible or rigid cables. - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs or trip-free switches. - Operating voltage: 0.7 to 1.1 x Un Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un Direct rotary handle -Padlockable - Equipped with front cover and handle - Fixing without any additional screw. Extended rotary handle - IP 55 - Supplied complete with shaft and handle. Technical information: - Visit our website at www.hagerelectro.com.au Accessories HXA021H Description Characteristics Cat ref. Auxiliary contacts AX AL 1 changeover contact (ON/OFF) 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC HXA021H HXA024H Shunt trips SH Undervoltage releases UV HXA004H HXA014H HXA024H HXA001H HXA002H HXA003H HXA004H HXA005H HXA011H HXA013H HXA014H HXA015H Accessories Description HXA031H HYA015H Direct rotary handle Padlockable Extended rotary handle Padlockable Padlocking device To mount on MCCB for handle locking 3 padlocks Collar terminals Terminals for aluminium conductor Extended connections Straight connections Spreader connections Interphase barriers Terminal covers Din rail adaptor Characteristics Cat ref. Cat ref. 3P 4P Max Ø 6mm HXA030H HXA030H Max Ø 8mm 200mm Max Ø 8mm HXA031H HXA031H HXA039H HXA039H Set of 3 or 4 HYA005H HYA006H Set of 4 Set of 3 or 4 Set of x 2 Height: 50mm For extended straight connections For extended spreader connections For collar terminal HYA013H HYA014H HYA019H HYA013H HYA015H HYA019H HYA021H HYA023H HYA022H HYA024H HYA027H HYA033H HYA028H HYA033H HYA021H C.11 Main Switches & Isolators Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. MCCBs x250 Moulded case circuit breakers x250 - Adjustable thermal and magnetic trip unit - 3P and 4P - Mechanical test button - Lockable settings - Integrated padlocking handle Ø 4mm - Complies with IEC60947-2. Connection: - Terminal area width 25mm Connection capacity: -185mm2 rigid cables - Collar terminals optional Technical information: - Visit our website at www.hagerelectro.com.au *Please check availability with your local Hager sales office at time of order MCCBs x250 40kA Description HNB160U C.12 Breaking capacity Icu: 40 kA (400/415V AC) Ics: 20 kA Adjustable thermal 0.63 - 0.8 - 1x In Adjustable magnetic 6 - 8 - 10 - 13 x In (160/200A) 5 - 7 - 9 - 11 x In (250A) 4P neutral setting: 0 or 100% In 160A 200A 250A Cat ref. Cat ref. 3P 4P* HNB160U HNB200U HNB250U HNB161U HNB201U HNB251U MCCBs x250 - accessories Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs or trip-free switches. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle -Padlockable - Equipped with front cover and handle - Fixing without any additional screw. Extended rotary handle -IP55 - Supplied complete with shaft and handle. Technical information: - Visit our website at www.hagerelectro.com.au Accessories HXA021H Description Characteristics Cat ref. Auxiliary contacts AX AL 1 changeover contact 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0.4A 1NO + 1NC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Max Ø 6mm HXA021H HXA024H Shunt trips SH Undervoltage releases UV HXA004H HXA014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Motor operators HXB040H HXA024H HXA001H HXA002H HXA003H HXA004H HXA005H HXA011H HXA013H HXA014H HXA015H HXB030H HXB031H Max Ø 8mm 200mm Max Ø 8mm HXA039H 24V DC 230 - 240V AC HXB040H HXB042H Accessories Cat ref. HYB022H HYB024H Characteristics 3P 4P Interlocking Collar terminals Aluminium / copper conductors 150mm2 rigid cables 185mm2 flexible cables Extended connections For straight connections Wire type Set of 4 pieces HXB065H HYB001H HXB065H HYB002H Set of 4 pieces Set of 4 pieces Set of 3 pieces Set of 3 Height: 97mm For extended straight connections For extended spreader connections For rear connections For collar terminals HYB010H HYB011H HYB031H HYB019H HYB010H HYB012H HYB032H HYB019H HYB021H HYB023H HYB022H HYB024H HYB025H HYB027H HYB026H HYB028H For spreader connections Rear connections Interphase barriers Terminal covers HYB031H Cat ref. Description C.13 Main Switches & Isolators Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. MCCBs h250 Moulded case circuit breakers h250 - 3P & 4P - Mechanical test button, sealable settings. - Comply with IEC 60947-2. Connection: Terminal area width 25 mm Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir = 0.4 to 1 x In - Short delay (magnetic equivalent) adjustable: 2.5 to 10 x Ir - Time delay: 0.1 - 0.2s Technical information: - Visit our website at www.hagerelectro.com.au *Please check availability with your local Hager sales office at time of order MCCBs h250 50kA LSI Description - Breaking capacity Icu: 50 kA (400/415V AC) Ics: 25 kA HNC250H - Adjustable thermal Ir = 0.4 to 1 x In Characteristics Cat ref. Cat ref. 3P 4P* 40A 125A 250A HNC040H HNC125H HNC250H HNC041H HNC126H HNC251H Characteristics Cat ref. Cat ref. - Adjustable magnetic 2.5 to 10 x Ir MCCBs h250 70kA LSI Description HEC250H C.14 - Breaking capacity Icu: 70 kA (400/415V AC) Ics: 70 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir 40A 125A 250A 3P 4P* HEC040H HEC125H HEC250H HEC041H HEC126H HEC251H MCCBs h250 - accessories Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs or trip-free switches. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle -Padlockable - Equipped with front cover and handle - Fixing without any additional screw. Extended rotary handle -IP55 - Supplied complete with shaft and handle. Technical information: - Visit our website at www.hagerelectro.com.au Accessories HXC021H Description Characteristics Cat ref. Auxiliary contacts AX AL 1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC HXC021H 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Ø 5 - 8mm2 max HXC002H HXC003H HXC004H HXC005H HXC011H HXC013H HXC014H HXC015H HXC030H Ø 5 - 8mm2 max 320mm Max Ø 5mm HXC031H 24V DC 230-240V AC HXC040H HXC042H HXC065H HXC024H Shunt trips SH Undervoltage releases UV HXC004H HXC014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Motor operators HXC039H HXC024H HXC001H HXC039H Interlocking Wire type Accessories Description HYC011H Collar terminals Extended connections Rear connections Interphase barriers Terminal covers HYC031H Characteristics Copper Straight connections Spreader connections Cat ref. 3P 4P HYC003H HYC010H HYC011H HYC031H HYC019H HYC004H HYC010H HYC012H HYC032H HYC019H Set of 3 Height: 97mm For extended straight connections HYC021H (LSI only) HYC025H For rear connections HYC027H For collar terminals HYC022H HYC026H HYC028H C.15 Main Switches & Isolators Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. MCCBs h630 Moulded case circuit breakers h630 - 3P & 4P - Adjustable neutral 0 - 50% - 100% - Mechanical test button, lockable settings - Comply with IEC 60947-2. Connection: - Directly on copper cable terminal, with end lug max. width: 30mm Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir = 0.4 to 1 x In - Short delay (magnetic equivalent) adjustable: 2.5 to 10 x Ir (400A) 2.5 to 8 x Ir (630A) - Time delay: 0.1 - 0.2 s Technical information: - Visit our website at www.hagerelectro.com.au *Please check availability with your local Hager sales office at time of order MCCBs h630 50kA LSI Description HND630H - Breaking capacity Icu: 50 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir (400A) 2.5 to 8 x Ir (630A) - Time delay: 0.1 - 0.2s In Cat ref. Cat ref. 3P 4P* 400A 630A HND400H HND630H HND401H HND631H In Cat ref. Cat ref. MCCBs h630 70kA LSI Description HED630H C.16 - Breaking capacity Icu: 70 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir (400A) 2.5 to 8 x Ir (630A) - Time delay: 0.1 - 0.2s 400A 630A 3P 4P* HED400H HED630H HED401H HED631H MCCBs h630 - accessories Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle -Padlockable - Equipped with front cover and handle - Fixing without any additional screw. Technical information: - Visit our website at www.hagerelectro.com.au Extended rotary handle -IP55 - Supplied complete with shaft and handle. Main Switches & Isolators Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. Accessories HXC021H Description Characteristics Cat ref. Auxiliary contacts AX AL 1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Max Ø 6 mm HXC021H HXC024H Shunt trips SH Undervoltage releases UV HXC004H HXC014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Max Ø 8mm 320mm Max Ø 8mm HXC024H HXC001H HXC002H HXC003H HXC004H HXC005H HXC011H HXC013H HXC014H HXC015H HXD030H HXD031H HXD039H HXD030H HXD039H C.17 MCCBs h630 - accessories Accessories Cat ref. HXD042H HYD003H Description Characteristics Motor operators 24-48V DC 100-240V AC Interlocking Wire type Collar terminals Terminals for copper conductors 1 x 35 - 240mm2 Terminals for multiple aluminium/copper conductors 2 x 35 - 240mm2 Extended connections For straight connections For spreader connections HYD015H HYD022H HYD033H C.18 Terminal covers For extended straight connections For extended spreader connections For rear connections For collar terminals Cat ref. 3P 4P HXD040H HXD042H HXD065H HXD040H HXD042H HXD065H Set of 3 or 4 160 - 400A HYD003H HYD004H Set of 3 or 4 400 - 630A HYD007H HYD008H Set of 4 pieces 400A 630A 400A 630A 400A 630A HYD010H HYD013H HYD011H HYD014H HYD031H HYD033H HYD019H HYD010H HYD013H HYD012H HYD015H HYD032H HYD034H HYD019H HYD021H HYD023H HYD022H HYD024H HYD025H HYD027H HYD026H HYD028H Set of 4 pieces Rear connections Interphase barriers In Set of 3 Height: 97mm MCCBs h1000 Moulded case circuit breakers h1000 - 3P & 4P - Adjustable neutral 0 - 50% - 100% - Mechanical test button, lockable settings. Connection: - Direct on copper terminal, with end lug max. width: 50mm - Comply with IEC60947-2. Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir= 0,4 to 1 x In - Short delay (magnetic equivalent) adjustable: 2,5 to 10 x Ir (630-800A) 2.5 to 8 x Ir (1000A) - Time delay: 0.1-0.2s Technical information: - Visit our website at www.hagerelectro.com.au Main Switches & Isolators *Please check availability with your local Hager sales office at time of order MCCBs h1000 50kA LSI Description HNE970H - Breaking capacity Icu: 50 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0,4 to 1 x In - Adjustable magnetic 2,5 to 10 x Ir (800A) 2,5 to 8 x Ir (1000A) - Time delay: 0.1-0.2s - Neutral setting from 0-50 to 100% In 800A 1000A Cat ref. Cat ref. 3P 4P* HNE800H HNE970H HNE801H HNE971H MCCBs h1000 70kA LSI Description HEE801H - Breaking capacity Icu: 70 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0,4 to 1 x In - Adjustable magnetic 2,5 to 10 x Ir (800A) 2,5 to 8 x Ir (1000A) - Time delay: 0,1-0,2s - Neutral setting from 0-50 to 100% In 800A 1000A Cat ref. Cat ref. 3P 4P* HEE800H HEE970H HEE801H HEE971H C.19 MCCBs h1000 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle -Padlockable - Equipped with front cover and handle - Fixing without any additional screw. Technical information: - Visit our website at www.hagerelectro.com.au Extended rotary handle -IP55 - Supplied complete with shaft and handle. Accessories HXC021H Description Characteristics Cat ref. Auxiliary contacts AX AL 1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC HXC021H HXC024H Shunt trips SH Undervoltage releases UV HXC004H HXE014H Direct rotary handle Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCB for handle locking 3 padlocks Motor operators HXD039H 48V DC 100 - 120V 200 - 240V 380 - 450V 24V DC 100 - 120V 200 - 240V 380 - 450V HXC024H HXC001H HXC002H HXC003H HXC004H HXC005H HXE011H HXE013H HXE014H HXE015H HXE030H AC AC AC AC AC AC HXE031H Max Ø 8mm 320mm Max Ø 8 mm HXD039H HXE040H HXE042H HXE065H 24 - 48V DC 100 - 240V AC Interlocking Wire type Accessories Description HYE031H C.20 Terminal covers For extended connections For rear connections Rear connections In 800A 1000A Cat ref. Cat ref. 3P 4P* HYE021H HYE025H HYE031H HYE033H HYE022H HYE026H HYE032H HYE034H MCCBs h1600 Moulded case circuit breakers h1600 - 3 pole - 3 trip units 4 pole - 4 trip units - Adjustable neutral 0 - 50% - 100% - Mechanical test button, lockable settings. - Comply with IEC60947-2. - Short delay (magnetic equivalent) adjustable: 2.5 to 10 x Ir - Time delay: 0.1-0.2 Technical information: - Visit our website at www.hagerelectro.com.au Connection: - Directly on copper cable terminal, with end lug max. width: 60mm *Please check availability with your local Hager sales office at time of order MCCBs h1600 50kA LSI Description HNF990H - Breaking capacity Icu: 50 kA (400/415V AC) Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir - Time delay: 0.1-0.2s - Neutral setting 0, 50, 100% In 1250A 1600A Cat ref. Cat ref. 3P 4P* HNF980H HNF990H HNF981H HNF991H MCCBs h1600 70kA LSI Description HEF980H In 1250A - Breaking capacity Icu: 70 kA (400/415V AC) 1600A Ics: 50 kA - Adjustable thermal Ir = 0.4 to 1 x In - Adjustable magnetic 2.5 to 10 x Ir - Time delay: 0.1-0.2s - Neutral setting from 0, 50, 100% Cat ref. Cat ref. 3P 4P* HEF980H HEF990H HEF981H HEF991H C.21 Main Switches & Isolators Electronic trip unit LSI: - Long delay (thermal equivalent) adjustable: Ir = 0.4 to 1 x In MCCBs h1600 - accessories Indication contacts - 1 changeover switch (ON/OFF): indicates the position of the MCCB is “open” or “closed”. - 1 changeover alarm contact: indicates MCCB tripping. Coil connection - Connection capacity: 0.75mm2 flexible or rigid cables - Optional connection cables. The cable capacity of the terminals is 0.5 to 1.25mm2. Shunt trip - Remote tripping of MCCBs. Operating voltage: 0.7 to 1.1 x Un. Under voltage release - Allows the tripping of MCCBs when voltage level drops between 35 and 70% of Un. - Pick up voltage 0.85 x Un. Direct rotary handle -Padlockable - Equipped with front cover and handle - Fixing without any additional screw. Technical information: - Visit our website at www.hagerelectro.com.au Extended rotary handle -IP55 - Supplied complete with shaft and handle. Rear connection included Accessories HXC021H Description Characteristics Cat ref. Auxiliary contacts AX AL 1 changeover contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 1 changeover alarm contact 250V AC / 3A 125V DC / 0,4A 1NO + 1NC 24V DC HXC021H HXF001H 48V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC 24V DC 100 - 120V AC 200 - 240V AC 380 - 450V AC Max Ø 8mm HXF002H HXF003H HXF004H HXF005H HXE011H HXE013H HXE014H HXE015H HXF030H Max Ø 8mm 320mm Max Ø 8mm HXF031H HXF039H 24V DC 200 - 230V AC HXF040H HXF042H HXC024H Shunt trips SH Undervoltage releases UV HXF004H HXE014H Direct rotary handles Padlockable Extended rotary handles Padlockable Padlocking device To mount on MCCBs for handle locking 3 padlocks Motor operators HXF040H C.22 HXC024H Load break switches Technical data - Visualised breaking - Double breaking per phase - 3 or 4 pole - Padlockable handle - Auxiliary contacts - Rotary handles complete with extension shaft - Complying with IEC60947-3 Main Switches & Isolators Description The HA series is a range of multi-pole load disconnector switches with manual operation. They enable making and breaking on load and safety isolation of any low voltage installation. DIN & screw mount isolators Description Width Characteristics Module mm Cat ref. 3 pole 400V~ 6 mod 6 mod 6 mod 8.5 mod 8.5 mod 8.5 mod 6 mod 8.5 mod In In In In In In In In 108 108 108 142 142 142 108 142 HA304 HA305 HA306 HA307 HA308 HA309M HA406 HA408 Description Width Characteristics Module mm Cat ref. 3 pole 400V~ - In In In In In In In In - HA354 HA356 HA358 HA360 HA362 HA364 HA457 HA458 HA305 4 pole 400V~ 80A 100A 125A 160A 200A 250A 125A 200A Screw mount isolators HA354 4 pole 400V~ 250A 400A 630A 800A 1250A 1600A 400A - AC23 630A - AC23 C.23 Load break switches Accessories Description The HA series is a range of multi-pole load disconnector switches with manual operation. They enable making and breaking on load and safety isolation of any low voltage installation. Technical data -Visualised breaking -Double breaking per phase -DIN rail mounting -3 or 4 pole -Padlockable handle -Auxiliary contacts -Complying with IEC60947-3 Rotary handles Description Characteristics Cat ref. To suit HA360/HA362/HA364 To suit HA354/HA356/HA358 To suit HA304/HA305/ HA306/HA307/HA308 Black IP65 Black IP55 Black IP55 HZC003 HZC002 HZC001 HZC003 Extension shafts HZC106 Description Characteristics Cat ref. To suit HA360/HA362/HA364 To suit HA354/HA356/HA358 To suit HA304/HA305/ HA306/HA307/HA308 320mm 320mm 200mm HZC106 HZC102 HZC103 Auxiliary contacts HZ022 Description Characteristics Cat ref. Suitable for HA304/HA305/ HA306/HA307/HA308 Suitable for HA354/HA356/ HA358/HA360/HA362/HA364 In 5A -250V~ HZ022 In 16A - 250V~ HZ023 Terminal shrouds HZC203 C.24 Description Width Cat ref. To suit HA354 Switch-line or load side To suit HA356/HA358/ Switch-line or load side To suit HA307/HA308 Switch-line or load side (Cable lug connection) To suit HA307/HA308/ Switch c/- cable clamp line or load side 1 mod HZC203 1 mod HZC205 1 mod HZ062 1 mod HZ072 Cat ref. thermal current Ith insulation voltage Ui (V) impulse withstand voltage Uimp (kV) rated operation current (A) AC-21A / AC-21B 400V AC(1) AC-22A / AC-22B AC-23A / AC-23B AC-20A / AC-20B 690V AC(2) AC-22A / AC-22B AC-23A / AC-23B 220V DC DC-20A / DC-20B operational power (kW) 400V AC 690V AC short time withstand current 1 sec (kA rms) short circuit making capacity (kA peak) connection max. cable section (mm) max. busbar width (mm) (1) (2) HA305 100 800 8 A/B 100/100 100/100 100/100 100/100 40/40 25/25 100/100 HA306 125 800 8 A/B 125/125 125/125 125/125 125/125 40/40 25/25 125/125 HA307 160 800 8 A/B 160/160 160/160 160/160 160/160 160/160 63/80 160/160 HA308 200 800 8 A/B 200/200 200/200 200/200 200/200 160/160 63/80 200/200 HA309M 250 800 8 A/B 200/250 200/200 200/200 200/250 160/160 63/80 200/250 40 51 63 80 100 100 33 33 33 150 150 150 2.5 12 2.5 12 2.5 12 4 16 4 16 4 16 50 - 50 - 50 - 95 20 95 20 95 20 A/B = category with index - A = frequent operation / B = infrequent operation with terminal shrouds or phase barriers Cat ref. thermal current Ith insulation voltage Ui (V) impulse withstand voltage Uimp (kV) rated operation current (A) AC-21A / AC-21B 400V AC(1) AC-22A / AC-22B AC-23A / AC-23B AC-20A / AC-20B 690V AC(2) AC-22A / AC-22B AC-23A / AC-23B 220V DC DC-20A / DC-20B operational power (kW) 400V AC 690V AC short time withstand current 1 sec (kA rms) short circuit making capacity (kA peak) connection max. cable section (mm) max. busbar width (mm) (1) (2) HA304 80 800 8 A/B 80/80 80/80 80/80 80/80 40/40 25/25 80/80 HA354 250 800 8 A/B 250/250 250/250 250/250 250/250 200/250 125/160 250/250 HA356 400 1000 12 A/B 400/400 400/400 400/400 400/400 400/400 250/315 400/400 HA358 630 1000 12 A/B 630/630 630/630 500/630 630/630 500/500 315/315 630/630 HA360 800 1000 12 A/B 800/800 800/800 800/800 800/800 800/800 800/800 800/800 HA362 1250 1000 12 A/B 1250/1250 1250/1250 1250/1250 1250/1250 1000/1000 1000/1000 1250/1250 HA364 1600 1000 12 A/B 1600/1600 1600/1600 1250/1250 1600/1600 1000/1000 1000/1000 1600/1600 132/132 90/110 220/220 150/185 280/280 150/185 450/450 185/220 710/710 475/475 710/710 475/475 9 30 13 45 13 45 26 55 50 110 50 110 150 32 240 40 2 x 300 50 2 x 300 63 4 x 185 100 6X185 100 A/B = category with index - A = frequent operation / B = infrequent operation with terminal shrouds or phase barriers Application condition & utilisation category, according to IEC 60947-3 Utilisation category AC DC AC20 DC20 AC21 DC21 AC22 DC22 AC23 DC23 Use Application Off-load making & breaking Resistive loads including moderate overloads Disconnector Switches at installation head or for resistive circuits (lighting) Switches in secondary circuits or reactive circuits (capacitor banks) Switches feeding one or serveral motor or inductive circuits (series motors, magnetic brakes) Inductive & resistive mixed loads including moderate overloads Loads made of motors or other hightly inductive loads Subject to technical change. C.25 Main Switches & Isolators Load break switches - characteristics (according to IEC 60947-3) Earth leakage relays & toroids Description This range of earth leakage relays were designed on an electronic basis, which ensure the monitoring of earth fault currents. When the fault current rises above the selected level, the outputs of the relay operate & depending on the relay selected, it can have both adjustable sensitivity and time delay that can provide selectivity/ discrimination. The relays are linked with detection toroids. Common characteristics - Standard DIN EN60947-2, IEC60755, IEC61008-8 - Fixed & adjustable devices - Positive safety: the relay trips in the event of a break in the connection between relay & toroid. - Positive / local reset required after a fault is detected. - Protected against nuisance tripping - Class A - Output: 1c/o contact 250V~ 6A AC1 - Visual display of fault - Supply voltage 230V +/- 20% 50/60Hz Premium features - Adjustable sensitivity & time delay (sealable) - Display of fault current prior to triggering relay (5%-75%) - Extra output contact (250V-AC1/6A) to enable remote indication of fault currents above 50% of Irn - Remote test and reset by three wire link Connection capacity - Flexible - 1 to 2.5mm - Stranded/rigid - 1.5 to 4mm supply contactor trip earth leakage relay detection toroid conforms to IEC 1008 Earth leakage relays HR510 HR520 Description Width Cat ref. Without delay c/o contact 250V 6A ~ AC1 Fixed sensitivity = 300mA Trips immediately Standard c/o contact 250V 6A ~ AC1 Adjustable sensitivity Irn= 0.03/0.1/0.3/0.5/1/3/10A Adjustable time delay rt= 0/0.1/0.3/0.4/0.5/1/3sec Premium c/o contact 250V 6A ~ AC1 Fail safe contact 250V 6A ~ AC1 Pre-alarm contact 250V 6A ~ AC1 Adjustable sensitivity Irn= 0.03/0.1/0.3/0.5/1/3/10A Adjustable time delay rt= 0/0.1/0.3/0.4/0.5/1/3sec Bargraph = 5% - 75% Irn Integral toroid c/o contact 250V 6A ~ AC1 Adjustable sensitivity Irn= 0.03/0.1/0.3/0.5/1/3A Adjustable time delay rt= 0/0.1/0.3/0.5/0.75/1sec Ø of toroid: 35mm 1 mod HR502 3 mod HR510 3 mod HR520 6 mod HR441 Circular section toroids Characteristics HR700 C.26 Inside Inside Inside Inside Inside Ø Ø Ø Ø Ø of of of of of Cat ref. toroid: toroid: toroid: toroid: toroid: 30mm 35mm 70mm 105mm 140mm HR700 HR701 HR702 HR703 HR704 Technical specifications for Residual current (earth leakage) relays Earth leakage relays Permissible overload of the toroid Test & reset push button voltage Type A Increased immunity (HI) Voltage & fault indication Signalling current default Bar graph indication Standard output (1OF) Fail safe output (1OF) 50% Irn output Analog output W/o adjustment Adjustable HR502 HR510 HR520 1 3 3 230V +/- 20% 50 à 700V 3 VA 5 VA Potential free changeover contacts 5A / 250V AC1 6A / 250V AC1 0.3A 0.03 / 0.1/0.3 / 0.5/ 1/ 3/10 Instant 0/0,1s/0,3s/0,4s 0/0,1s/0,3s/0,4s /0,5s/1s/3s /0,5s/1s/3s/5S 30 kA / 100 ms 100 - 250V yes yes yes yes yes yes no yes yes - Maximum cable length to test & reset Maximum cable length between toroid & relay Connection. Relay: cage terminals rigid/stranded flexible Connection. Toroid: rigid/stranded flexible Operating temperature Storage temperature Standard compliance 200m 50m maximum width 1,5mm² twisted pair cable - 25m for non twisted cable 1,5 to 4 mm² 1,5 to 4 mm² 1 to 2,5 mm² 1 to 2,5 mm² 1,5 to 4 mm² 1,5 to 4 mm² 1 to 6 mm² 1 to 6 mm² -10 to +55°C -25 to +70°C IEC 60947-2 annexe B, IEC 61543, IEC 61008-1, IEC 60755 6 VA 0.03 / 0.1/0.3 / 0.5/ 1/ 3 0s /0,1s /0,3s /0,5s/0,75s/1s Main Switches & Isolators Number of modules Supply voltage ~50/60Hz Network voltage ~50/60Hz Power consumption Output command Contact rating (standard output, fail safe, 50% pre-alarm) Residual current settings Irn Delay on opening (+/- 20%) With integrated toroid HR441 6 no 0,03A Irn = 2,25 mV/mA 0,1A Irn = 2,25 mV/mA 0,3A Irn = 2,25 mV/mA 0,5A Irn = 2,25 mV/mA 1A Irn = 2,25 mV/mA 3A Irn = 2,25 mV/mA Toroids Internal diameter of toroid Maximum screw torque Maximum connection distance between toroid & ELR Rated frequency Connection: rigid/stranded cable Connection section in flexible cable for the measurement Operating temperature Storage temperature Rated voltage for alternating use Rated insulation voltage Rated impulse withstand voltage IP for torroids HR700 HR701 HR702 30mm 35mm 70mm 1Nm 50m max with twisted pair cable 50-60 Hz 1 to 1.5 mm² 1,5 à 4 mm² 1 to 1,5mm² HR703 105mm HR704 140mm 1,5 à 2,5mm² -10 to +55°C -25 to +70°C 50 to 700V 250V 4kV IP41 Application notes Discrimination between Residual Current Devices Hager residual current relays (HR210, HR212) have adjustable time delay and residual current settings. They can be used as an upstream device to achieve residual current protection of the entire installation. It is advisable to set the residual current relay at a residual higher tripping current than a downstream devices (> 30mA) since the upstream device will see the accumulation of leakage currents from the entire installation. The residual current setting will depend on the quantity and type of equipment connected to the installation (Immersion water heaters, switch mode power supplies are particularly prone to leakage currents to earth). The time delay should be set above zero to 300ms. In theory it is possible to achieve current discrimination between residual current devices, but the limit of discrimination is far too low for practical purposes. Time delay is the only reliable & by far the best method used to obtain discrimination. It can be achieved by delaying the tripping of the upstream residual current devices. The downstream device would typically be a 30mA or occasionally a 10mA residual current device. Typically they will operate within 40ms and occasionally much faster. If further levels of protection are required upstream from the Hager residual current relay, then another residual current relay can be installed upstream and the settings of the device (time and residual current) adjusted higher again. Subject to technical change. C.27 Hager Electro Pty Ltd 1/170 Power Street Glendenning NSW 2761 www.hagerelectro.com.au Nationwide sales Ph 1300 850 253 Fx 1300 424 372 Email: customerservice@hagerelectro.com.au State offices in: New South Wales North Queensland South East Queensland South Australia Victoria Western Australia Distributors in: Northern Territory Tasmania