EE1 TORK DIGITAL MULTI-PURPOSE, 1 CHANNEL DG180/120/100 24-Hour APPLICATIONS Ideal for single circuit HVAC units. Use to control: • Compressors • Ventilating Fans • Pumps • Security Systems • Billboard Signs Same schedule everyday - can omit operation on selected days. ON and OFF SET POINTS Total # Per Day Minimum Setting 288 5 minutes ©<§• LISTED Meets California Energy Commission Title 24 requirements. 7-Day APPLICATIONS Indoor/outdoor lighting and HVAC equipment. Use for: • School warning and other traffic lights. • Water heaters in offices, churches, and factories. Capable of different schedules each day of the week. Special day (holiday) schedule can be executed at any time for any number of days. ON and OFF SET POINTS Total # Per Week Minimum Setting 32 1 minute DPDT units can control 2 separate loads. ORDERING INFORMATION Type Model 24 Hour 7 Day 7 Day 7 Day DG DG DG DG Clock Input 50/60 Hz 180* 100* 120 120-2 Dry Contacts (unpowered) SPOT SPOT DPDT DPDT 120V AC 120V AC 120V AC 240VAC * Models DG100 and DG180 units are available in 240 VAC - add suffix 2, 277 VAC - add suffix 3, 24 VAC - add suffix 24, 12 VDC add suffix 12. Model DG120 is available in 24 VAC - consult factory. Model DG120 is not available in 277 VAC. STANDARD FEATURES (ALL MODELS) Daylight Saving Leap Year Display Manual Override Clock Format Power Outage Backup LCD Until the next regularly scheduled ON or OFF. Automatic operation then resumes. AM/PM (can be set to 24 hour if required) Battery back-up retains schedules - uses standard 9V conveniently accessible from the front. Lithium averages 450 hours. Alkaline averages 175 hours. vvinnivj uir •\vanmvi DG120 71 SUPPLY |Q|C3|®|®|<S>| H I L 4 NO 1 C NC DPDT I rl TIMER SUPPLY , K>" LOAD rl |<S|<S>||Q|<S>|<S>|(S>|<S)|<S>| ^ N NO C 1 NC LL •-$ NO | CSA UL NO 20A 6A 20A 6A NC NO NC 125V AC 15A 15A 10A 240VAC 10A 6A 3A 277VAC 10A Resistive 28VDCI 20A Motor Load 120VAC 1/2 HP 1/4 HP 240VAC 1 HP 1/2HP Pilot Duty 120/240VAC 470VA 275VA 277VAC 690VA t Model DG120 is 15A tt Does not apply to DG120 Timing Accuracy: Line frequency Operating Temperature: -4 to +122° F (-20° to +50° C) Storage Temperature: -22 to +167° F (-30 to +75° C) Relative Humidity: 0 to 90% R.H. (non-condensing) Enclosure: See end of controls section for dimensions. Noryl" indoor/outdoor (NEMA 3R) is standard. For Metal Indoor (add suffix Y to cat. #) - Model 63100. Other Mountings: Metal indoor/outdoor (suffix O) - Model 9000A. Flush with lock and key (suffix FLG) - Model 9011. Bracket for panel mounting - consult factory. 10A Resistive or 120/240VACt 3A Inductive 277VACtt 10A Resistive 28VDCf 3A Ballast 277VACtt Pilot Duty 120/240VAC 470VA 275VA 277VAC 690VA Motor Load 120VAC 1 HP 1/4 HP 240VAC 2 HP 1/2 HP General Purpose SPECIFICATION WRITER'S GUIDE Automatic adjustment (can be omitted) Automatic compensation DG100/DG180 SPECIFICATIONS Power Consumption: 4VA Max. Contact Ratings: C I L^° N NC Model DG180 1. Furnish and install TORK Model DG180 digital time switch. 2. Controller shall be capable of 288 set points. 3. Controller shall program in 5 minute resolution. 4. Controller shall repeat the same schedule each day or be capable of omitting any selected days. APPLIES TO BOTH MODELS 5. Controller shall program in AM/PM or 24 Hour format. 6. Display shall be LCD. 7. Controller shall have daylight saving or standard time. 8. Controller shall have automatic leap year compensation. 9. Controller shall have battery backup capability of 450 hours with Lithium or 175 hours with Alkaline batten/. 10. Controller shall be capable of manual override ON or OFF to the next scheduled event. 11. Unit shall have an indoor/outdoor Noryl enclosure as standard. Model DG100/DG120 1. Furnish and install TORK Model DG100/DG120 digital time switch. 2. Controller shall be capable of 32 set points. 3. Controller shall program in 1 minute resolution. 4. Controller shall be capable of a different schedule each day of the week. Write 5-11 as above. TORIC 1 Grove St., Mt. Vernon, NY 10550 • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com •a TORK ENCLOSURE DIMENSIONS METAL INDOOR/OUTDOOR NEMA 3 Model 9000A - Suffix O METAL INDOOR NEMA 1 #68229 STD. FOR MODELS 1101 1102 1103 1104 r*-4-11/16"-H T 7122 8001 7-15/16" 8004 1101FM 1104FM 8011 8061 8121 7100 8301 7102 8601 8602 7200 7202 E100 Series, 7120 EH 10/20 C^ STD. FOR MODELS 7300, (L) 7302, (L) 7300Z 7302Z 7300ZL 7302ZL 1 1847AL 1847AZL 8001 8004 8007V E100 Series 8001U 8007 8301 8601 8602 DW, DWZ, DZS, DTS Series #63100 METAL INDOOR/OUTDOOR NEMA 3 Model 9006 - Suffix O 7220, (L) 1847AL LC200 1847AZL LDS-A 8001L LDSH-A 8007 8007L 8007V 8150 81 SOU 7222, (L) 7200L 7202L 7120L 1847A 1848A 1849A T 3-3/4 I 1847AZ AVAILABLE FOR SERIES DZS, DTS, DW, DWZ, DG 8011 8061 8121 8007L METAL INDOOR NEMA1 STD. FOR MODELS lol (replaces Model 9000) AVAILABLE FOR MODELS 1101 7200, (L,Z,ZL) 1102 7202, (L,Z,ZL) 1103 7120, (L,Z,ZL) 1104 7122, (L,ZL) 1101FM 7220, (L) 1104FM 7222, (L) 7100 1847A 7102 1847AZ JJ_ -5-1/4-- AVAILABLE FOR MODELS T920L W100 W222 W220L W200 T930L W202 W222L 1847AW W300L W300 1847AWL W302L W302 TW220L W120 TW300L W220 METAL INDOOR/OUTDOOR - NEMA 3 Model 90131-Suffix O METAL INDOOR NEMA1 #63016-1 STD. FOR MODELS TZ220L W302L TZ300L TW220L W300 TW300L W302 T920L W300L T930L METAL INDOOR NEMA1 #70100 STD. FOR MODELS W100 W222 W200 W220L W202 W222L W120 1847AW W220 1847 AWL METAL INDOOR NEMA1 STD. FOR MODELS W400A W400AL W402A W402AL TORK DIMENSIONS: 10-1/2" x 7-7/8" x 4-3/4" AVAILABLE FOR MODELS W400AL W402AL 4-3/4" L NORYL® INDOOR/OUTDOOR NEMA 3R Model 9000N Suffix N STD. FOR MODELS 7200Z,(L) DG Series DWZ Series 7202Z,(L) DZS Series SMC-3D 7120Z,(L) DTS Series 7122ZL DW Series AVAILABLE FOR MODELS 1101 1102 1103 1104 7102 7202, (L,Z,ZL) 7120, (L,Z,ZL) 7122 7122ZL 7220, (L) 7222, (L) 1847A 1847AZ 7200, (L,Z,ZL) 1847'AL 1101FM 1104FM 7100 1847AZL 8602 8001 E100 Series 8004 8001U 8011 8061 8121 8301 8601 1 Grove St., Mt. Vernon, NY 10550 • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com