I rl rl

advertisement
EE1
TORK DIGITAL
MULTI-PURPOSE, 1 CHANNEL
DG180/120/100
24-Hour
APPLICATIONS
Ideal for single circuit HVAC units. Use to control:
• Compressors
• Ventilating Fans
• Pumps
• Security Systems
• Billboard Signs
Same schedule everyday - can omit operation on
selected days.
ON and OFF SET POINTS
Total # Per Day
Minimum Setting
288
5 minutes
©<§•
LISTED
Meets California
Energy Commission
Title 24 requirements.
7-Day
APPLICATIONS
Indoor/outdoor lighting and HVAC equipment. Use for:
• School warning and other traffic lights.
• Water heaters in offices, churches, and factories.
Capable of different schedules each day of the week.
Special day (holiday) schedule can be executed at any
time for any number of days.
ON and OFF SET POINTS
Total # Per Week
Minimum Setting
32
1 minute
DPDT units can control 2 separate loads.
ORDERING INFORMATION
Type
Model
24 Hour
7 Day
7 Day
7 Day
DG
DG
DG
DG
Clock Input
50/60 Hz
180*
100*
120
120-2
Dry Contacts
(unpowered)
SPOT
SPOT
DPDT
DPDT
120V AC
120V AC
120V AC
240VAC
* Models DG100 and DG180 units are available in 240 VAC - add
suffix 2, 277 VAC - add suffix 3, 24 VAC - add suffix 24, 12 VDC add suffix 12. Model DG120 is available in 24 VAC - consult factory.
Model DG120 is not available in 277 VAC.
STANDARD FEATURES (ALL MODELS)
Daylight Saving
Leap Year
Display
Manual Override
Clock Format
Power Outage
Backup
LCD
Until the next regularly scheduled ON or OFF.
Automatic operation then resumes.
AM/PM (can be set to 24 hour if required)
Battery back-up retains schedules - uses standard
9V conveniently accessible from the front.
Lithium averages 450 hours.
Alkaline averages 175 hours.
vvinnivj uir •\vanmvi
DG120
71
SUPPLY
|Q|C3|®|®|<S>|
H
I
L
4
NO
1
C
NC
DPDT
I rl
TIMER
SUPPLY
, K>"
LOAD
rl
|<S|<S>||Q|<S>|<S>|(S>|<S)|<S>|
^
N
NO
C
1
NC
LL
•-$
NO
|
CSA
UL
NO
20A
6A
20A
6A
NC
NO
NC
125V AC
15A
15A
10A
240VAC
10A
6A
3A
277VAC
10A
Resistive
28VDCI 20A
Motor Load 120VAC 1/2 HP 1/4 HP
240VAC
1 HP 1/2HP
Pilot Duty 120/240VAC 470VA 275VA
277VAC 690VA
t Model DG120 is 15A
tt Does not apply to DG120
Timing Accuracy: Line frequency
Operating Temperature: -4 to +122° F (-20° to +50° C)
Storage Temperature: -22 to +167° F (-30 to +75° C)
Relative Humidity: 0 to 90% R.H. (non-condensing)
Enclosure: See end of controls section for dimensions.
Noryl" indoor/outdoor (NEMA 3R) is standard.
For Metal Indoor (add suffix Y to cat. #) - Model 63100.
Other Mountings:
Metal indoor/outdoor (suffix O) - Model 9000A.
Flush with lock and key (suffix FLG) - Model 9011.
Bracket for panel mounting - consult factory.
10A
Resistive or 120/240VACt
3A
Inductive
277VACtt
10A
Resistive
28VDCf
3A
Ballast
277VACtt
Pilot Duty 120/240VAC 470VA 275VA
277VAC 690VA Motor Load
120VAC 1 HP 1/4 HP
240VAC 2 HP 1/2 HP
General
Purpose
SPECIFICATION WRITER'S GUIDE
Automatic adjustment (can be omitted)
Automatic compensation
DG100/DG180
SPECIFICATIONS
Power Consumption: 4VA Max.
Contact Ratings:
C
I
L^°
N
NC
Model DG180
1. Furnish and install TORK Model DG180 digital time switch.
2. Controller shall be capable of 288 set points.
3. Controller shall program in 5 minute resolution.
4. Controller shall repeat the same schedule each day or be capable
of omitting any selected days.
APPLIES TO BOTH MODELS
5. Controller shall program in AM/PM or 24 Hour format.
6. Display shall be LCD.
7. Controller shall have daylight saving or standard time.
8. Controller shall have automatic leap year compensation.
9. Controller shall have battery backup capability of 450 hours with
Lithium or 175 hours with Alkaline batten/.
10. Controller shall be capable of manual override ON or OFF to
the next scheduled event.
11. Unit shall have an indoor/outdoor Noryl enclosure as standard.
Model DG100/DG120
1. Furnish and install TORK Model DG100/DG120 digital time switch.
2. Controller shall be capable of 32 set points.
3. Controller shall program in 1 minute resolution.
4. Controller shall be capable of a different schedule each day of the
week.
Write 5-11 as above.
TORIC 1 Grove St., Mt. Vernon, NY 10550 • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com
•a
TORK ENCLOSURE DIMENSIONS
METAL INDOOR/OUTDOOR
NEMA 3
Model 9000A - Suffix O
METAL INDOOR NEMA 1
#68229
STD. FOR MODELS
1101
1102
1103
1104
r*-4-11/16"-H
T
7122
8001
7-15/16"
8004
1101FM
1104FM
8011
8061
8121
7100
8301
7102
8601
8602
7200
7202
E100 Series,
7120
EH 10/20
C^
STD. FOR MODELS
7300, (L)
7302, (L)
7300Z
7302Z
7300ZL
7302ZL
1
1847AL
1847AZL
8001
8004
8007V
E100 Series
8001U
8007
8301
8601
8602
DW, DWZ, DZS, DTS Series
#63100
METAL INDOOR/OUTDOOR
NEMA 3
Model 9006 - Suffix O
7220, (L)
1847AL
LC200
1847AZL LDS-A
8001L
LDSH-A
8007
8007L
8007V
8150
81 SOU
7222, (L)
7200L
7202L
7120L
1847A
1848A
1849A
T
3-3/4
I
1847AZ
AVAILABLE
FOR SERIES
DZS, DTS,
DW, DWZ,
DG
8011
8061
8121
8007L
METAL INDOOR
NEMA1
STD. FOR MODELS
lol
(replaces Model 9000)
AVAILABLE FOR MODELS
1101
7200, (L,Z,ZL)
1102
7202, (L,Z,ZL)
1103
7120, (L,Z,ZL)
1104
7122, (L,ZL)
1101FM
7220, (L)
1104FM
7222, (L)
7100
1847A
7102
1847AZ
JJ_
-5-1/4--
AVAILABLE FOR MODELS
T920L
W100
W222
W220L
W200
T930L
W202
W222L
1847AW
W300L
W300
1847AWL
W302L
W302
TW220L
W120
TW300L
W220
METAL INDOOR/OUTDOOR - NEMA 3
Model 90131-Suffix O
METAL INDOOR
NEMA1
#63016-1
STD. FOR MODELS
TZ220L
W302L
TZ300L
TW220L
W300
TW300L
W302
T920L
W300L
T930L
METAL INDOOR
NEMA1
#70100
STD. FOR MODELS
W100
W222
W200
W220L
W202
W222L
W120
1847AW
W220
1847 AWL
METAL INDOOR
NEMA1
STD. FOR MODELS
W400A
W400AL
W402A
W402AL
TORK
DIMENSIONS: 10-1/2" x 7-7/8" x 4-3/4"
AVAILABLE FOR MODELS
W400AL
W402AL
4-3/4"
L
NORYL® INDOOR/OUTDOOR
NEMA 3R
Model 9000N Suffix N
STD. FOR MODELS
7200Z,(L)
DG Series
DWZ Series
7202Z,(L)
DZS Series
SMC-3D
7120Z,(L)
DTS Series
7122ZL
DW Series
AVAILABLE FOR MODELS
1101
1102
1103
1104
7102
7202, (L,Z,ZL)
7120, (L,Z,ZL)
7122
7122ZL
7220, (L)
7222, (L)
1847A
1847AZ
7200, (L,Z,ZL)
1847'AL
1101FM
1104FM
7100
1847AZL
8602
8001
E100 Series
8004
8001U
8011
8061
8121
8301
8601
1 Grove St., Mt. Vernon, NY 10550 • Tel: 914-664-3542 • Fax: 914-664-5052 • Internet: http://www.tork.com
Download