JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System FEATURES Features • Economical • High performance Ribbon Window/Curtain Wall system • Narrow 2-1/4" sight line • 4-1/2", 6" and 7-1/2" system depths for 1" infill • 5-1/4" and 6-3/4 system depths for 1/4" infill • Inside glazed • Incidental water management capability • Integral perimeter caulk leg • Thermally improved • Snap-on covers • Two color option • PermanodicTM anodized finishes in seven choices • • • • Painted finishes in standard and custom choices Type “A” fabrication: Screw Splice or Shear Block Type “B” fabrication: Punched openings SSG Option Optional Features • Steel reinforcing available • Rain screen and backpans • Pressure plate option for outside glazing requirements • Integrates with GLASSventTM windows for curtain wall • Profit$Maker™ plus die sets available. Product Applications • Ideal for low to high-rise applications © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-099 For specific product applications, Consult your Kawneer representative. kawneer.com ADMD150EN 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System BLANK PAGE ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 EC 97911-099 JULY, 2016 JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System EC 97911-099 3 INDEX Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. MISCELLANEOUS DETAILS - 1/4" INFILL ......................................21 WIND LOAD CHARTS.................................................................. 22-33 DEADLOAD CHARTS.................................................................. 34-37 THERMAL CHARTS .................................................................... 38-45 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. PICTORIAL VIEW............................................................................. 5-7 DETAILS - 1" INFILL...................................................................... 8-10 ENTRANCE DETAILS - 1" INFILL.....................................................11 CORNERS - 1" INFILL.......................................................................12 GLASSventTM WINDOWS FOR CURTAIN WALL - 1" INFILL...........13 MISCELLANEOUS DETAILS - 1" INFILL .........................................14 DETAILS - 1/4" INFILL................................................................. 15-17 ENTRANCE DETAILS - 1/4" INFILL..................................................18 CORNERS - 1/4" INFILL....................................................................19 GLASSventTM WINDOWS FOR CURTAIN WALL - 1/4" INFILL........20 The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD150EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System BLANK PAGE ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 EC 97911-099 JULY, 2016 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 2250 IG (Inside Glazed) Curtain Wall System EC 97911-099 PICTORIAL VIEW TYPE “A” ASSEMBLY Screw Spline for Ribbon Windows VERTICAL MULLION HEAD THERMAL ISOLATOR COVER ADMD150EN GLASS STOP HORIZONTAL GLASS STOP SILL 5 HEAD THERMAL ISOLATOR GLASS STOP SILL COVER ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 PICTORIAL VIEW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 EC 97911-099 JULY, 2016 TYPE “B” ASSEMBLY Screw Spline for Ribbon Windows GLASS STOP HORIZONTAL © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 2250 IG (Inside Glazed) Curtain Wall System EC 97911-099 PICTORIAL VIEW SHEAR BLOCK ASSEMBLY Shear Block for Curtain Wall VERTICAL MULLION SHEAR BLOCK HEAD THERMAL ISOLATOR COVER ADMD150EN GLASS STOP HORIZONTAL GLASS STOP FLAT FILLER SILL 7 4A 1A 4 5 4A 5A 4 6 3A 5A 6A 1 1A 2 2A ELEVATION IS NUMBER KEYED TO DETAILS 3 3A 4A 6" (152.4) 6" (152.4) 1 1A 2 2A 3 3A 2-1/4" (57.2) 2-1/4" (57.2) 5 5A ADMD150EN 6 6A kawneer.com © Kawneer Company, Inc., 2013 RIBBON WINDOW (TYPE "A" SCREW SPLINE - 1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 5 6" (152.4) 4 2-1/4" (57.2) SCALE 3" = 1'-0" 6" (152.4) 6" (152.4) 2-1/4" (57.2) 8 EC 97911-099 JULY, 2016 NOTE: Available in 4-1/2", 6" (Shown) and 7-1/2" depths. Consult you Kawneer Representative for more information. 1 4 4A 1A 4 5 4A 5A 4 kawneer.com 2-1/4" (57.2) 3 5 6 5A 6A 4A 2-1/4" (57.2) SCALE 3" = 1'-0" ELEVATION IS NUMBER KEYED TO DETAILS 2-1/4" (57.2) 2-1/4" (57.2) 5 5A ADMD150EN 6" (152.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-099 6" (152.4) 6" (152.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System 1 1A 2 2A 3 3A 6" (152.4) 6" (152.4) 1 1A 2 2A 3 3A 6 9 RIBBON WINDOW (TYPE "B" SCREW SPLINE - 1" INFILL) NOTE: Available in 4-1/2", 6" (Shown) and 7-1/2" depths. Consult you Kawneer Representative for more information. 1 3A 6A 6A 6 8 3 7A 8A 4 3 4 2 2A 5 5A NOTE: Available in 4-1/2", 6" (Shown) and 7-1/2" depths. Consult you Kawneer Representative for more information. 6A 6" (152.4) 6" (152.4) 1 1A 2 2A ELEVATION IS NUMBER KEYED TO DETAILS 3 4 5 ADMD150EN 5A 2-1/4" (57.2) 2-1/4" (57.2) 7 7A 8 8A kawneer.com © Kawneer Company, Inc., 2013 CURTAIN WALL (SHEAR BLOCK - 1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 2-1/4" (57.2) 2250 IG (Inside Glazed) Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 6" (152.4) 6 6" (152.4) 6" (152.4) 2-1/4" (57.2) 10 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" 1A 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 11 ENTRANCE DETAILS (1" INFILL) SCALE 3" = 1'-0" 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 1A 1B 3 1 TRANSOM BAR 4 B/H OR O/P BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER C/H ELEVATION IS NUMBER KEYED TO DETAILS 1A TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING CONCEALED OVERHEAD CLOSER 3 1B BUTT HUNG OR OFFSET PIVOT 1-7/8" (47.6) DOOR JAMB © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7/8" (22.2) TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVERHEAD CLOSER OR SURFACE CLOSER 2 TRANSOM BAR 4 CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER DOOR JAMB CENTER HUNG kawneer.com ADMD150EN 90° OUTSIDE CORNER SCREW SPLINE 90° OUTSIDE CORNER SHEAR BLOCK 90° INSIDE CORNER SCREW SPLINE 90° INSIDE CORNER SHEAR BLOCK ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 CORNERS (1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 2250 IG (Inside Glazed) Curtain Wall System EC 97911-099 GLASSventTM WINDOWS FOR CURTAIN WALL (1" INFILL) SCALE 3" = 1'-0" GLASSventTM WINDOWS FOR CURTAIN WALL HEAD SILL JAMB ADMD150EN JAMB AT SSG MULLION 13 MISCELLANEOUS (1" INFILL) PRESSURE PLATE HORIZONTAL FOR OUTSIDE GLAZING STEEL REINFORCING OPTIONAL STEEL REINFORCING AS REQUIRED ADMD150EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" 2-1/4" (57.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-099 4 4A 3 4 4 kawneer.com 1 5 4A 4 5 6 5 6 ELEVATION IS NUMBER KEYED TO DETAILS 4A 5 ADMD150EN 5-1/4" (133.4) 5-1/4" (133.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System 2-1/4" (57.2) 6 15 RIBBON WINDOW (TYPE "A" SCREW SPLINE - 1/4" INFILL) SCALE 3" = 1'-0" NOTE: Available in 5-1/4" (Shown) and 6-3/4" depths. Consult you Kawneer Representative for more information. 1 4A 3 5-1/4" (133.4) 1 1 2 3 2 3 4 1 4 4 4A 4 1 5 5 6 4A 3 5 6 5-1/4" (133.4) 1 1 2 3 ELEVATION IS NUMBER KEYED TO DETAILS 3 2-1/4" (57.2) 4A 5 ADMD150EN 6 kawneer.com © Kawneer Company, Inc., 2013 4A 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. RIBBON WINDOW (TYPE "B" SCREW SPLINE - 1/4" INFILL) 5-1/4" (133.4) 5-1/4" (133.4) 2-1/4" (57.2) 16 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" NOTE: Available in 5-1/4" (Shown) and 6-3/4" depths. Consult you Kawneer Representative for more information. MAX. UNIT WIDTH 24’-0” 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. kawneer.com 4 5 6 4 5 6 4 2-1/4" (57.2) EC 97911-099 ELEVATION IS NUMBER KEYED TO DETAILS 5 ADMD150EN 5-1/4" (133.4) 5-1/4" (133.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System 1 2 2 5-1/4" (133.4) 1 2 3 2 3 2-1/4" (57.2) 6 17 CURTAIN WALL (SHEAR BLOCK - 1/4" INFILL) SCALE 3" = 1'-0" NOTE: Available in 5-1/4" (Shown) and 6-3/4" depths. Consult you Kawneer Representative for more information. 2250 IG (Inside Glazed) Curtain Wall System 18 JULY, 2016 ENTRANCE DETAILS ( 1/4" INFILL) EC 97911-099 TRANSOM BAR 4 BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P C/H ELEVATION IS NUMBER KEYED TO DETAILS 1A TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CLOSER 7/8" (22.2) 3 1-7/8" (47.6) DOOR JAMB BUTT HUNG OR OFFSET PIVOT 1B TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVERHEAD CLOSER OR SURFACE CLOSER 2 4 TRANSOM BAR DOOR JAMB CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER CENTER HUNG ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 3 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 1 1A 1B Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 2250 IG (Inside Glazed) Curtain Wall System EC 97911-099 CORNERS ( 1/4" INFILL) SCALE 3" = 1'-0" 90° OUTSIDE CORNER SCREW SPLINE 90° OUTSIDE CORNER SHEAR BLOCK 90° INSIDE CORNER SCREW SPLINE 90° INSIDE CORNER SHEAR BLOCK ADMD150EN 19 GLASSventTM WINDOWS FOR CURTAIN WALL (1/4" INFILL) GLASSventTM WINDOWS FOR CURTAIN WALL HEAD SILL JAMB ADMD150EN JAMB AT SSG MULLION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 20 EC 97911-099 JULY, 2016 SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JULY, 2016 kawneer.com 2250 IG (Inside Glazed) Curtain Wall System EC 97911-099 MISCELLANEOUS (1/4" INFILL) SCALE 3" = 1'-0" PRESSURE PLATE HORIZONTAL FOR OUTSIDE GLAZING STEEL REINFORCING OPTIONAL STEEL REINFORCING AS REQUIRED ADMD150EN 21 22 2250 IG (Inside Glazed) Curtain Wall System WIND LOAD / DEAD LOAD CHARTS JULY, 2016 EC 97911-099 DEADLOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. A conversion from Load Resistance Factor Design (LRFD) is provided. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 23 WIND LOAD CHARTS (1" INFILL) (TYPE "A" SCREW SPLINE) SINGLE SPAN A= B= C= D= E= 16 15 .5 1 1.5 2 B LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) SINGLE SPAN METERS 1 C 4 D E 4.5 13 4 10 7 2 6 5 1.5 4-1/2" (114.3) 2.5 8 METERS 3 9 4 3.5 11 A 10 3 B 9 C D E 8 7 2.5 METERS 3.5 11 MULLION HEIGHT IN FEET 12 2-1/4" (57.2) 12 MULLION HEIGHT 13 2 6 5 1.5 4 1 3 165124 & 165029 I = 3.014(125.4 x 104) S = 1.315(21.6 x 103) .5 1 2 I = 0.769(32.0 x 104) S = 0.672(11.0 x 103) .5 1 2 3 4 5 6 7 0 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN METERS .5 16 1 METERS 1.5 2 4 A 2.5 7 2 6 5 6" (152.4) 8 METERS 3 D E 9 MULLION HEIGHT IN FEET C 3-3/4" (95.3) 3.5 B 1 1.5 2 1.5 4 4.5 14 B 13 C 4 D E 3.5 12 MULLION HEIGHT 12 11 .5 15 4.5 14 13 A 16 15 10 8 11 10 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 165110 & 165016 165125 & 165016 I = 6.885(286.5 x 104) S = 2.161(35.4 x 103) I = 2.810(117.0 x 104) S = 1.455(23.8 x 103) 0 1 3 2 .5 1 0 0 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD150EN 8 METERS 1 1 3 165119 & 165029 2 MULLION HEIGHT IN FEET 2 14 0 © Kawneer Company, Inc., 2013 1.5 15 4.5 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 16 14 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS A Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System 24 JULY, 2016 WIND LOAD CHARTS (1" INFILL) EC 97911-099 (TYPE "A" SCREW SPLINE) A= B= C= D= E= METERS 1 1.5 2 A 15 SINGLE SPAN METERS 7 2 MULLION HEIGHT IN FEET 2.5 8 7-1/2" (190.5) 9 METERS 3 5-1/4" (133.4) E 10 4.5 4 A 12 3.5 MULLION HEIGHT D 2 13 4 11 1.5 14 13 12 1 15 B C .5 16 4.5 14 6 5 1.5 4 3.5 11 B 10 3 9 E D 8 C 2.5 7 2 6 5 1.5 4 1 3 2 .5 1 1 3 165132 & 166010 165134 & 166010 I = 13.354(555.8 x 104) S = 3.291(53.9 x 103) I = 6.800(283.0 x 104) S = 2.499(41.0 x 103) 0 2 .5 1 0 1 2 3 4 5 6 7 0 8 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) METERS .5 16 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 25 WIND LOAD CHARTS (1" INFILL) (TYPE "B" SCREW SPLINE) SINGLE SPAN A= B= C= D= E= A 15 B 14 C 13 D E .5 1 1.5 2 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) SINGLE SPAN METERS 4 4.5 4 7 2 6 5 1.5 4-1/2" (114.3) 2.5 8 METERS 3 9 2-1/4" (57.2) MULLION HEIGHT 10 MULLION HEIGHT IN FEET 12 4 3.5 11 A 10 3 B 9 C D E 8 7 2.5 2 6 5 1.5 4 1 3 165123 I = 3.500(145.7 x 104) S = 1.582(25.9 x 103) .5 1 2 I = 0.749(31.2 x 104) S = 0.649(10.6 x 103) .5 1 2 3 4 5 6 7 0 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN METERS METERS .5 16 1 1.5 2 13 4 B E 8 2.5 7 2 6 5 6" (152.4) 3 D 9 METERS C MULLION HEIGHT IN FEET 3.5 3-3/4" (95.3) MULLION HEIGHT A 11 1 1.5 2 A 15 4.5 14 12 .5 16 15 10 8 1.5 4.5 14 B 13 C 12 D E 11 4 3.5 10 3 9 2.5 8 7 2 6 5 1.5 4 4 1 3 165099 2 .5 1 165107 I = 7.350(305.9 x 104) S = 2.540(41.6 x 103) I = 2.624(109.2 x 104) S = 1.378(22.6 x 103) 1 3 2 .5 1 0 0 0 1 2 3 4 5 6 7 0 8 kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET ADMD150EN 8 METERS 1 1 3 165112 2 MULLION HEIGHT IN FEET 2 13 3.5 11 0 © Kawneer Company, Inc., 2013 1.5 14 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 15 4.5 12 .5 16 METERS 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System 26 JULY, 2016 WIND LOAD CHARTS (1" INFILL) EC 97911-099 (TYPE "B" SCREW SPLINE) A= B= C= D= E= METERS 1 1.5 A 15 B 14 METERS 1 1.5 2 15 4.5 14 13 4 D 4 A MULLION HEIGHT E 10 2.5 8 7 2 7-1/2" (190.5) 9 METERS 3 MULLION HEIGHT IN FEET 12 3.5 11 5-1/4" (133.4) 12 .5 16 4.5 C 13 6 5 1.5 4 3.5 11 D 10 B C 3 E 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 1 3 165138 165077 I = 15.061(626.9 x 104) S = 4.129(67.7 x 103) I = 6.949(289.2 x 104) S = 2.612(42.8 x 103) 0 2 .5 1 0 1 2 3 4 5 6 7 0 8 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET 2 SINGLE SPAN METERS .5 16 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 27 WIND LOAD CHARTS (1" INFILL) (SHEAR BLOCK) SINGLE SPAN A= B= C= D= E= .5 1 1.5 2 B C 13 D E 12 METERS 16 1 4.5 13 4 4 12 10 MULLION HEIGHT 3.5 7 2 6 5 1.5 4-1/2" (114.3) 2.5 8 METERS 3 9 3.5 11 A 10 3 B 9 C D E 8 7 2.5 2 6 5 1.5 4 4 1 3 1 3 165048 165128 2 I = 3.328(138.5 x 104) S = 1.572(25.8 x 103) .5 1 2 I = 0.770(32.1 x 104) S = 0.682(11.2 x 103) .5 1 0 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS METERS .5 1 8 1.5 2 .5 30 15 1.5 1 2 9 29 4.5 14 A 28 13 A 12 8 2.5 E 7 2 6 5 1.5 MULLION HEIGHT IN FEET D MULLION HEIGHT EQUAL EQUAL 9 METERS 3 6" (152.4) C MULLION HEIGHT B 10 8 26 3.5 11 8.5 27 4 25 7.5 24 B 23 22 C 21 1 3 165127 2 .5 1 I = 7.223(300.6 x 104) S = 2.442(40.0 x 103) 0 6.5 20 D 19 6 E 18 4 7 5.5 17 5 16 15 4.5 14 0 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD150EN 8 METERS 1 16 MULLION HEIGHT IN FEET 2 14 11 0 © Kawneer Company, Inc., 2013 1.5 15 4.5 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 METERS 14 SINGLE SPAN MULLION HEIGHT IN FEET 15 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) 2-1/4" (57.2) 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS A Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System 28 JULY, 2016 WIND LOAD CHARTS (1" INFILL) EC 97911-099 (SHEAR BLOCK) 2 A 15 METERS 2 9 B 28 B C 26 E 10 9 2.5 8 7 METERS 3 2 6 5 1.5 MULLION HEIGHT IN FEET D 11 MULLION HEIGHT EQUAL EQUAL 3.5 6" (152.4) 12 8.5 27 4 MULLION HEIGHT 13 8 C 25 7.5 24 D 23 7 22 E 21 6.5 20 6 19 18 4 1 3 1 0 0 1 2 3 4 5 6 7 5 16 Ia = 7.223(300.6 x 104) Sa = 2.442(40.0 x 103) Is = 2.228(92.7 x 104) Ss = 1.456(23.9 x 103) .5 5.5 17 165127 & 162362 Steel 2 15 4.5 14 8 0 1 2 5 6 7 8 SINGLE SPAN TWIN SPAN 1 METERS 1.5 2 15 B 9 8.5 27 4 8 9 2.5 8 7 2 6 5 METERS 3 MULLION HEIGHT EQUAL EQUAL 10 1.5 MULLION HEIGHT IN FEET 26 3.5 3-3/4" (95.3) D E 2 28 MULLION HEIGHT C 12 1.5 1 29 4.5 13 .5 30 A 11 4 MULLION CENTERS IN FEET METERS 14 3 MULLION CENTERS IN FEET .5 16 MULLION HEIGHT IN FEET 1.5 1 29 4.5 14 MULLION HEIGHT IN FEET .5 30 METERS 1.5 25 7.5 24 23 7 22 A 21 6.5 20 6 19 B 18 4 1 3 165044 2 .5 1 I = 2.606(108.5 x 104) S = 1.382(22.7 x 103) METERS 1 5.5 17 D C 16 15 5 E 4.5 14 0 0 1 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 METERS .5 16 TWIN SPAN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. A= B= C= D= E= LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 29 WIND LOAD CHARTS (1" INFILL) (SHEAR BLOCK) SINGLE SPAN A= B= C= D= E= 2 METERS .5 30 14 9 A 2.5 8 7 2 6 5 1.5 4 MULLION HEIGHT IN FEET 9 MULLION HEIGHT EQUAL EQUAL 3 3-3/4" (95.3) E D METERS 10 MULLION HEIGHT 3.5 C 11 1 3 1 2 3 4 5 6 7 25 8 C 7.5 24 D 23 7 22 E 21 6.5 20 6 19 18 5.5 5 16 Ia = 2.606(108.5 x 104) Sa = 1.382(22.7 x 103) Is = 2.228(92.7 x 104) Ss = 1.456(23.9 x 103) .5 B 26 17 165044 & 162362 Steel 2 1 15 4.5 14 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS 8 METERS 2 A B 13 12 C 11 D 10 E 1.5 2 9 B 28 8.5 27 4 8 26 3.5 3 9 2.5 8 7 2 6 5 1.5 MULLION HEIGHT IN FEET 14 1 29 4.5 MULLION HEIGHT EQUAL EQUAL 15 .5 30 7-1/2" (190.5) 1.5 MULLION HEIGHT 1 METERS .5 16 8.5 27 4 B 12 MULLION HEIGHT IN FEET 2 28 A 13 0 © Kawneer Company, Inc., 2013 1.5 1 29 4.5 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. TWIN SPAN 25 C 24 7.5 D 23 7 E 22 6.5 21 20 6 19 18 4 1 3 165139 2 .5 1 I = 13.857(576.8 x 104) S = 3.705(60.7 x 103) 0 5.5 17 5 16 15 4.5 14 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET kawneer.com METERS 1.5 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) ADMD150EN 8 METERS 1 15 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 16 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System 30 JULY, 2016 WIND LOAD CHARTS (1" INFILL) EC 97911-099 (SHEAR BLOCK) A= B= C= D= E= METERS 1 1.5 2 15 TWIN SPAN METERS 1 1.5 2 9 29 4.5 14 A 28 13 A 2 6 5 1.5 MULLION HEIGHT IN FEET 7 MULLION HEIGHT EQUAL EQUAL 2.5 5-1/4" (133.4) E 8 METERS 9 3 MULLION HEIGHT 3.5 C D 10 8 26 B 11 8.5 27 4 12 B 25 7.5 C 24 23 7 22 D 21 20 6.5 E 6 19 18 4 1 3 165064 2 .5 1 I = 6.327(263.3 x 104) S = 2.409(39.5 x 103) 0 5.5 17 5 16 15 4.5 14 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET .5 30 METERS .5 16 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 31 WIND LOAD CHARTS (1/4" INFILL) (TYPE “A” SCREW SPLINE) SINGLE SPAN A= B= C= D= E= 16 1 1.5 2 15 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) SINGLE SPAN METERS .5 16 A 4.5 B 13 4 9 3 D E 8 2.5 7 2 6 5 MULLION HEIGHT IN FEET B C 5-1/4" (133.4) 10 3.5 6-3/4" (171.45) A 11 METERS 12 MULLION HEIGHT 12 1.5 4 C 11 3.5 D 10 3 E 9 2.5 8 7 METERS 13 2 6 5 1.5 4 4 1 3 1 3 2 165257 & 165016 165277 & 166010 I = 5.203(216.6 x 104) S = 1.828(30.0 x 103) I = 10.964(456.4 x 104) S = 2.941(48.2 x 103) .5 1 2 .5 1 0 2 3 4 5 6 7 0 8 1 2 (TYPE “B” SCREW SPLINE) 1 5 6 2 .5 16 15 1 1.5 2 15 4.5 13 13 4 E 7 2 6 5 MULLION HEIGHT IN FEET 2.5 5-1/4" (133.4) D 8 METERS 3 C 6-3/4" (171.45) 3.5 B 9 MULLION HEIGHT A 1.5 4 4 B 12 11 4.5 A 14 14 10 8 METERS 1.5 12 7 SINGLE SPAN METERS .5 4 MULLION CENTERS IN FEET SINGLE SPAN 16 3 C 11 3.5 D 10 3 E 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 165263 165274 I = 5.381(224.0 x 104) S = 2.058(33.7 x 103) I = 12.108(504.0 x 104) S = 3.641(59.7 x 103) 0 1 3 2 .5 1 0 0 1 2 3 4 5 6 7 0 8 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD150EN 8 METERS 1 MULLION CENTERS IN FEET MULLION HEIGHT IN FEET 2 14 0 © Kawneer Company, Inc., 2013 1.5 15 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 4.5 14 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System 32 JULY, 2016 WIND LOAD CHARTS (1/4" INFILL) EC 97911-099 (SHEAR BLOCK) A= B= C= D= E= METERS 1 1.5 2 15 TWIN SPAN METERS 1 2 9 28 14 2.5 E 7 2 6 5 1.5 MULLION HEIGHT IN FEET D 8 MULLION HEIGHT EQUAL EQUAL C METERS 3 5-1/4" (133.4) B MULLION HEIGHT 3.5 11 9 8 26 A 10 8.5 27 4 12 A 25 7.5 24 23 7 22 B 21 1 3 6 19 C 1 D 16 I = 5.318(221.4 x 104) S = 1.996(32.7 x 103) .5 5.5 17 165264 2 6.5 20 18 4 15 0 5 E 4.5 14 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS .5 16 1 METERS 1.5 2 15 13 1 1.5 2 A 9 29 4.5 A 14 .5 30 28 B 12 8.5 B 27 4 8 26 C D 7 2 6 5 1.5 MULLION HEIGHT IN FEET 2.5 8 MULLION HEIGHT EQUAL EQUAL 9 5-1/4" (133.4) 3 E MULLION HEIGHT 10 3.5 METERS 11 25 7.5 24 C 23 7 22 21 D 6.5 E 6 20 19 18 4 1 3 165264 & 162362 Steel 2 .5 1 0 0 1 2 3 4 5 6 7 Ia = 5.318(221.4 x 104) Sa = 1.996(32.7 x 103) Is = 2.228(92.7 x 104) Ss = 1.456(23.9 x 103) 8 5.5 17 5 16 15 4.5 14 0 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 MULLION CENTERS IN FEET METERS 0 MULLION HEIGHT IN FEET 1.5 29 4.5 13 MULLION HEIGHT IN FEET .5 30 METERS .5 16 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 33 WIND LOAD CHARTS (1/4" INFILL) (SHEAR BLOCK) SINGLE SPAN A= B= C= D= E= 2 9 A 8.5 B 26 C D 3.5 E 3 9 2.5 8 7 2 6 5 1.5 8 25 7.5 24 C 23 7 D 22 6.5 21 E 20 6 19 18 4 1 3 165279 2 .5 1 I = 11.101(462.1 x 104) S = 3.211(52.6 x 103) 0 5.5 17 5 16 15 4.5 14 0 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 29 MULLION HEIGHT IN FEET 10 1.5 27 MULLION HEIGHT EQUAL EQUAL 11 1 28 B 12 METERS .5 30 4 6-3/4" (171.45) 13 TWIN SPAN ADMD150EN 8 METERS A 14 LRFD Ultimate Design Load 33 PSF (1580) 50 PSF (2400) 67 PSF (3200) 83 PSF (4000) 100 PSF (4790) 4.5 MULLION HEIGHT 1.5 METERS 1 15 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 16 Allowable Stress Design Load 20 PSF (960) 30 PSF (1440) 40 PSF (1920) 50 PSF (2400) 60 PSF (2880) 2250 IG (Inside Glazed) Curtain Wall System 34 JULY, 2016 DEADLOAD CHARTS EC 97911-099 A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 4-1/2" (114.3) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165115 165162 I = 0.405(16.9 x 104) S = 0.263(4.3 x 103) I = 0.373(14.5 x 104) S = 0.242(4.0 x 103) METERS .5 13 1 METERS 1.5 2 1 1.5 2 12 3.5 11 10 2 6 C METERS 2.5 7 5 GLASS HEIGHT IN FEET B 8 10 3 A 9 1.5 4 1 3 3.5 11 3 9 A 8 2.5 B 7 2 6 5 1.5 C 4 1 3 2 2 .5 .5 1 1 0 1 2 3 4 5 6 7 8 0 1 2 4 5 SPAN IN FEET 5-1/4" (133.4) 5-1/4" (133.4) 1 6 7 8 165259 165221 I = 0.475(19.8 x 104) S = 0.306(5.0 x 103) I = 1.202(50.0 x 104) S = 1.053(17.3 x 103) METERS .5 13 3 SPAN IN FEET METERS 1.5 2 12 1 .5 13 1.5 2 A 12 10 GLASS HEIGHT IN FEET B 2.5 7 2 6 5 METERS 8 10 3 A 9 1.5 4 1 3 3.5 11 3 9 B 8 2.5 7 2 6 5 1.5 4 1 3 2 METERS 3.5 11 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 8 SPAN IN FEET 0 1 2 3 4 5 6 7 8 SPAN IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 GLASS HEIGHT IN FEET METERS 12 GLASS HEIGHT IN FEET .5 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4-1/2" (114.3) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 35 DEADLOAD CHARTS A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 5-1/4" (133.4) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165262 165223 I = 0.457(19.0 x 104) S = 0.280(4.6 x 103) I = 0.546(22.7 x 104) S = 0.359(5.9 x 103) METERS 1 .5 13 METERS 1.5 2 GLASS HEIGHT IN FEET 9 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 B 10 3 B A 11 A 10 GLASS HEIGHT IN FEET 2 12 3.5 11 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 8 0 1 2 4 5 6 SPAN IN FEET 6" (152.4) 6" (152.4) 1 7 8 165111 165102 I = 0.463(19.3 x 104) S = 0.299(4.9 x 103) I = 0.447(18.6 x 104) S = 0.276(4.5 x 103) METERS METERS 1.5 2 1 .5 13 12 1.5 2 12 A 11 3.5 GLASS HEIGHT IN FEET 7 2 6 5 METERS 2.5 8 1.5 4 1 3 A B 10 3 C 9 3.5 11 B 10 GLASS HEIGHT IN FEET 3 SPAN IN FEET .5 13 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 3 C 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 0 1 2 3 4 5 6 7 0 8 0 SPAN IN FEET kawneer.com METERS 12 1 .5 13 1 2 3 4 5 SPAN IN FEET ADMD150EN 6 7 8 METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5-1/4" (133.4) 2250 IG (Inside Glazed) Curtain Wall System 36 JULY, 2016 DEADLOAD CHARTS EC 97911-099 A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 6-3/4" (171.45) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165275 165250 I = 0.589(24.5 x 104) S = 0.356(5.8 x 103) I = 1.882(79.3 x 104) S = 1.651(27.1 x 103) METERS 13 1 METERS 1.5 2 13 12 1 1.5 2 B 12 A 11 3.5 10 GLASS HEIGHT IN FEET 3 9 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 11 B 10 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 1 2 3 4 5 6 7 8 0 1 2 4 5 SPAN IN FEET 6-3/4" (171.45) 6-3/4" (171.45) 1 7 8 165272 165253 I = 0.654(27.2 x 104) S = 0.406(6.7 x 103) METERS METERS .5 6 I = 0.539(22.4 x 104) S = 0.319(5.2 x 103) 1.5 2 1 .5 13 13 1.5 2 12 12 A 11 3.5 10 GLASS HEIGHT IN FEET 3 9 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 11 B 10 GLASS HEIGHT IN FEET 3 SPAN IN FEET 3 9 A B 8 2.5 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 8 SPAN IN FEET SPAN IN FEET ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 METERS GLASS HEIGHT IN FEET .5 METERS .5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6-3/4" (171.45) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 37 DEADLOAD CHARTS A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 7-1/2" (190.5) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165133 165069 I = 0.583(24.3 x 104) S = 0.355(5.8 x 103) I = 0.332(13.8 x 104) S = 0.527(8.6 x 103) METERS .5 13 1 METERS 1.5 2 1.5 2 12 A 11 3.5 10 GLASS HEIGHT IN FEET 3 9 C 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 11 B 10 GLASS HEIGHT IN FEET 1 3 9 A 8 2.5 B 7 2 6 5 1.5 C 4 1 3 2 2 .5 .5 1 1 0 0 1 2 3 4 5 6 7 8 0 1 2 5 6 7-1/2" (190.5) 7-1/2" (190.5) 1 7 8 165137 165057 I = 0.534(22.2 x 104) S = 0.318(5.2 x 103) I = 0.251(10.5 x 104) S = 0.383 (6.3 x 103) METERS 1.5 2 .5 13 1 1.5 2 12 12 A 11 3.5 10 GLASS HEIGHT IN FEET 9 2.5 8 7 C 6 2 5 1.5 4 1 3 A 10 3 B 3.5 11 METERS GLASS HEIGHT IN FEET 4 SPAN IN FEET METERS © Kawneer Company, Inc., 2013 3 SPAN IN FEET .5 13 3 9 2.5 8 7 2 B 6 5 1.5 4 C 3 1 2 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET kawneer.com METERS 12 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 13 1 2 3 4 5 SPAN IN FEET ADMD150EN 6 7 8 METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7-1/2" (190.5) 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 THERMAL CHARTS EC 97911-099 Project Specific U-Factor Example Calculation 15'-8" F.W. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2'-0" D.L.O. 9'-6" F.H. 7'-0" D.L.O. 5'-0" D.L.O. = 0.42 Btu/(ft2·h·°F) Example Glass U-Factor Total Daylight (Vision) Area = 3(5' x 7') + 3(5' x 2') = 135 ft2 Projected Total Area = 15'-8" x 9'-6" = 148.83 ft2 Percent of Vision Glass = (Total Daylight Area ÷ Projected Total Area)100 = (135 ÷ 148.83)100 = 91% System U-factor vs Percent of Glass Area 0.40 0.30 70 75 80 85 Vision Area / Total Area % Based on 91% glass and center of glass U-factor of 0.42 system U-factor is equal to 0.49 Btu/hr·ft2·°F ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 0.50 0.49 0.20 90 91% COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 System U-factor (BTU/hr/ft2/°F) (N E L ) P ign M es A D X or E ot f 0.70 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.80 95 38 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 39 THERMAL CHARTS System U-Factors for Vision Glass (Captured Shear Block Option) 1.05 COG U-factor (6.00) 1.00 0.95 (5.50) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.90 (5.00) 0.85 (4.00) (3.50) 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 95 System U-factor 0.60 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 System U-factor Btu 2 hr·ft ·°F 0.65 W 2 m ·°C (4.50) 0.75 0.70 W 2 m ·°C 0.80 (3.00) 0.50 0.45 (2.50) 0.40 0.35 (2.00) 0.30 90 85 80 75 70 Vision Area / Total Area (%) Note: Values in parentheses are metric. COG = Center Of Glass. Charts are generated per AAMA 507. 0.95 COG U-factor (5.50) 0.90 (5.00) 0.85 0.80 (4.50) 0.75 0.70 0.60 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.50 (3.00) (2.50) 0.40 0.35 (2.00) 0.30 90 85 80 Vision Area / Total Area (%) kawneer.com (3.50) 0.45 0.25 95 (4.00) Btu 2 hr·ft ·°F 0.65 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System U-Factor for Vision Glass (Captured Ribbon Window Option) ADMD150EN 75 70 (1.50) 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 ADMD150EN 75 70 0.00 Vision Area / Total Area (%) Charts are generated per AAMA 507 kawneer.com © Kawneer Company, Inc., 2013 COG SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. THERMAL CHARTS (Captured Shear Block Option) System SHGC 40 EC 97911-099 JULY, 2016 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-099 COG VT 0.75 0.70 0.45 0.45 0.40 0.40 0.35 0.35 0.30 kawneer.com 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 Vision Area / Total Area (%) Charts are generated per AAMA 507 ADMD150EN 75 70 0.00 System VT JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System THERMAL CHARTS (Captured Shear Block Option) System Visible Transmittance (VT) vs Percent of Vision Area 0.80 0.75 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 41 COG SHGC 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 ADMD150EN 75 70 0.00 Vision Area / Total Area (%) Charts are generated per AAMA 507 kawneer.com © Kawneer Company, Inc., 2013 0.80 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THERMAL CHARTS (Captured Ribbon Window Option) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2250 IG (Inside Glazed) Curtain Wall System System SHGC 42 EC 97911-099 JULY, 2016 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-099 COG VT 0.75 0.70 0.45 0.45 0.40 0.40 0.35 0.35 0.30 kawneer.com 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 Vision Area / Total Area (%) Charts are generated per AAMA 507 ADMD150EN 75 70 0.00 System VT JULY, 2016 2250 IG (Inside Glazed) Curtain Wall System THERMAL CHARTS (Captured Ribbon Window Option) System Visible Transmittance (VT) vs Percent of Vision Area 0.80 0.75 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 43 2250 IG (Inside Glazed) Curtain Wall System THERMAL PERFORMANCE MATRIX (NFRC SIZE) Overall U-Factor 4 0.48 0.64 0.46 0.62 0.44 0.60 0.42 0.59 0.40 0.57 0.38 0.56 0.36 0.54 0.34 0.52 0.32 0.51 0.30 0.49 0.28 0.47 0.26 0.46 0.24 0.44 0.22 0.43 0.20 0.41 NOTE: For glass values that are not listed, linear interpolation is permitted. 1.U-Factors are determined in accordance with NFRC 100. 2.SHGC and VT values are determined in accordance with NFRC 200. 3.Glass properties are based on center of glass values and are obtained from your glass supplier. 4.Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.70 0.75 0.68 0.70 0.65 0.70 0.63 0.65 0.61 0.65 0.59 0.60 0.56 0.60 0.54 0.55 0.52 0.55 0.50 0.50 0.47 0.50 0.45 0.45 0.42 0.45 0.41 0.40 0.38 0.40 0.36 0.35 0.33 0.35 0.32 0.30 0.29 0.30 0.27 0.25 0.24 0.25 0.23 0.20 0.20 0.20 0.18 0.15 0.15 0.15 0.14 0.10 0.11 0.10 0.09 0.05 0.06 0.05 0.05 ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 Glass U-Factor 3 Captured Shear Block Option Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Thermal Transmittance1 (BTU/hr • ft 2 • °F) JULY, 2016 EC 97911-099 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 44 2250 IG (Inside Glazed) Curtain Wall System JULY, 2016 EC 97911-099 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.65 0.46 0.63 0.44 0.61 0.42 0.60 0.40 0.58 0.38 0.57 0.36 0.55 0.34 0.53 0.32 0.52 0.30 0.50 0.28 0.49 0.26 0.47 0.24 0.46 0.22 0.44 0.20 0.42 Captured Ribbon Window Option NOTE: For glass values that are not listed, linear interpolation is permitted. 1.U-Factors are determined in accordance with NFRC 100. 2.SHGC and VT values are determined in accordance with NFRC 200. 3.Glass properties are based on center of glass values and are obtained from your glass supplier. 4.Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). SHGC Matrix 2 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.66 0.70 0.64 0.70 0.62 0.65 0.59 0.65 0.57 0.60 0.55 0.60 0.53 0.55 0.50 0.55 0.48 0.50 0.46 0.50 0.44 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.35 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.26 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.11 0.10 0.09 0.05 0.06 0.05 0.04 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 45 ADMD150EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG (Inside Glazed) Curtain Wall System BLANK PAGE ADMD150EN kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 46 EC 97911-099 JULY, 2016