Accessories Isolated Alarm Contacts For Melting Alloy Overload

Accessories
Class 9999
www.us.schneider-electric.com
FOR CURRENT INFORMATION
Isolated Alarm Contacts For Melting Alloy Overload Relays
Isolated overload relay alarm contacts are available factory installed or in kit form for field installation in Type S,
NEMA Size 00–6a starters and Class 9065 Types M and S melting alloy overload relays. Type S, NEMA Size 7,
utilizes a solid state overload relay which has isolated alarm contacts as a standard feature. The alarm contacts
allow the starter to be used in applications which require isolated contacts, such as inputs to a computer.
Class 9999 Types SO4 and SO5 modules are interchangeable with the standard module (Class 9998 Type SO1)
and may be installed on starters already in service. The case is made of clear plastic (polycarbonate) to allow for
visual inspection of contacts.
Table 16.369: Contact Unit For Melting Alloy Overload Relays
Magnetic Starter
NEMA
Size
Type SO4
Class 9999
Type
$ Price
N.O. Isolated Alarm Contact Plus
SO4
Standard N.C. Overload Contact
77.
N.C. Isolated Alarm Contact Plus
SO5
Standard N.C. Overload Contact
Isolated alarm contacts cannot be added in the field to the Type S Size 5 starter. Current transformers and a Size 1 overload block must be used. For
factory installation specify Form Y342.
00-6a
a
Parts Kit Description
Type
SA-SH
Compression Lugs
A Class 9999 Type AL hardware kit is required to install Square D Versa-Crimp® compression lugs on Class 8903
Type S, 100–800 A lighting contactors. The lugs are suitable for both copper and aluminum wire.
One VCEL lug is required for each line or load terminal. Each Class 9999 Type AL hardware kit includes mounting
hardware for 3 terminals, line or load side.
EXAMPLE: To install compression lugs on a 300 A 3-Pole device, line and load sides, order six VCEL06012H1 lugs
and two Class 9999 Type AL11 hardware kits.
Table 16.370:
For Use With
VERSA-CRIMP
Catalog Number
Class 8903
Type
SQ
Rating
100 Amp
200 Amp
SV
VCEL02114S1
VCEL022516H1
VCEL024516H1
VCEL030516H1
VCEL05012H1
300 Amp
SX
VCEL06012H1
Wire Range
8–1/0 Al/Cu
2-Pole 1–2/0 Al/Cu
3-Pole 2/0–4/0 Al/Cu
4-Pole 4–300 kcmil Al/Cu
2/0–500 kcmil Al/Cu
400–600 kcmil Al
400–500 kcmil Cu
500–750 kcmil Al
500 kcmil Cu
400–600 kcmil Al
400–500 kcmil Cu
500–750 kcmil Al
500 kcmil Cu
VCEL07512H1
400 Amp
or
600 Amp
Class 8903
With Compression
Lugs Installed
b
VCEL06012H2b
SY
or
SZ
VCEL07512H2b
Hardware Kit
Class 9999
Type
None Required
$ Price
—
AL13—2-pole
AL14—3-pole
AL15—4-pole
95.00
119.00
143.00
AL11
36.50
AL12
71.30
One or two lugs may be mounted on each terminal.
Solid Neutral
The Class 9999 Type SN kit can be used on Class 8903 Type S lighting contactors and other controllers where field
addition of a solid neutral is required. Each kit has lugs suitable for both copper and aluminum wire, and mounts with
two screws.
Table 16.371:
No. of
Lugs
Wire Capacity
Per Lug (Cu/Al)
4
3
14–2/0
(1) 4–600 MCM or
(2) 1/0–250 MCM
(2) 2–600 MCM
(2) 6–350 MCM
3 (Dual)
2 (Dual)
Class 9999
Type
SN1
$ Price
89.
SN2
261.
SN3
SN4
416.
261.
Tie Point Terminal Block
16
The tie point terminal block provides easy wiring of a Hand-Off-Auto selector switch or Start-Stop push buttons with
separate control. The T7 terminal block requires no panel space. It simply snaps on Type S Sizes 00–4 contactors and
starters by two tabs and is secured to the left hand coil terminal.
NEMA/DEFINITE PURPOSE TYPE
CONTACTORS AND STARTERS
Table 16.372:
Tie Point Terminal Block
Magnetic
Contactor or Starter
NEMA Size
00–4
Type
SA-SF
Class 9999
Type
T7
$ Price
22.20
Table 16.373: How to Order
To Order Specify:
•
•
16-126
Catalog Number
Class
Type
9999
SO4
Class Number
Type Number
CP1
Discount
Schedule
© 2007 Schneider Electric
All Rights Reserved
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com