Accessories Class 9999 www.us.schneider-electric.com FOR CURRENT INFORMATION Isolated Alarm Contacts For Melting Alloy Overload Relays Isolated overload relay alarm contacts are available factory installed or in kit form for field installation in Type S, NEMA Size 00–6a starters and Class 9065 Types M and S melting alloy overload relays. Type S, NEMA Size 7, utilizes a solid state overload relay which has isolated alarm contacts as a standard feature. The alarm contacts allow the starter to be used in applications which require isolated contacts, such as inputs to a computer. Class 9999 Types SO4 and SO5 modules are interchangeable with the standard module (Class 9998 Type SO1) and may be installed on starters already in service. The case is made of clear plastic (polycarbonate) to allow for visual inspection of contacts. Table 16.369: Contact Unit For Melting Alloy Overload Relays Magnetic Starter NEMA Size Type SO4 Class 9999 Type $ Price N.O. Isolated Alarm Contact Plus SO4 Standard N.C. Overload Contact 77. N.C. Isolated Alarm Contact Plus SO5 Standard N.C. Overload Contact Isolated alarm contacts cannot be added in the field to the Type S Size 5 starter. Current transformers and a Size 1 overload block must be used. For factory installation specify Form Y342. 00-6a a Parts Kit Description Type SA-SH Compression Lugs A Class 9999 Type AL hardware kit is required to install Square D Versa-Crimp® compression lugs on Class 8903 Type S, 100–800 A lighting contactors. The lugs are suitable for both copper and aluminum wire. One VCEL lug is required for each line or load terminal. Each Class 9999 Type AL hardware kit includes mounting hardware for 3 terminals, line or load side. EXAMPLE: To install compression lugs on a 300 A 3-Pole device, line and load sides, order six VCEL06012H1 lugs and two Class 9999 Type AL11 hardware kits. Table 16.370: For Use With VERSA-CRIMP Catalog Number Class 8903 Type SQ Rating 100 Amp 200 Amp SV VCEL02114S1 VCEL022516H1 VCEL024516H1 VCEL030516H1 VCEL05012H1 300 Amp SX VCEL06012H1 Wire Range 8–1/0 Al/Cu 2-Pole 1–2/0 Al/Cu 3-Pole 2/0–4/0 Al/Cu 4-Pole 4–300 kcmil Al/Cu 2/0–500 kcmil Al/Cu 400–600 kcmil Al 400–500 kcmil Cu 500–750 kcmil Al 500 kcmil Cu 400–600 kcmil Al 400–500 kcmil Cu 500–750 kcmil Al 500 kcmil Cu VCEL07512H1 400 Amp or 600 Amp Class 8903 With Compression Lugs Installed b VCEL06012H2b SY or SZ VCEL07512H2b Hardware Kit Class 9999 Type None Required $ Price — AL13—2-pole AL14—3-pole AL15—4-pole 95.00 119.00 143.00 AL11 36.50 AL12 71.30 One or two lugs may be mounted on each terminal. Solid Neutral The Class 9999 Type SN kit can be used on Class 8903 Type S lighting contactors and other controllers where field addition of a solid neutral is required. Each kit has lugs suitable for both copper and aluminum wire, and mounts with two screws. Table 16.371: No. of Lugs Wire Capacity Per Lug (Cu/Al) 4 3 14–2/0 (1) 4–600 MCM or (2) 1/0–250 MCM (2) 2–600 MCM (2) 6–350 MCM 3 (Dual) 2 (Dual) Class 9999 Type SN1 $ Price 89. SN2 261. SN3 SN4 416. 261. Tie Point Terminal Block 16 The tie point terminal block provides easy wiring of a Hand-Off-Auto selector switch or Start-Stop push buttons with separate control. The T7 terminal block requires no panel space. It simply snaps on Type S Sizes 00–4 contactors and starters by two tabs and is secured to the left hand coil terminal. NEMA/DEFINITE PURPOSE TYPE CONTACTORS AND STARTERS Table 16.372: Tie Point Terminal Block Magnetic Contactor or Starter NEMA Size 00–4 Type SA-SF Class 9999 Type T7 $ Price 22.20 Table 16.373: How to Order To Order Specify: • • 16-126 Catalog Number Class Type 9999 SO4 Class Number Type Number CP1 Discount Schedule © 2007 Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com