Enclosed Magnetic Solutions Guide

advertisement
2810 South Raritan Street, Englewood, Colorado 80110
www.palmerdcs.com
Phone: 720-484-8547
Fax: 303-330-0179
Enclosed Magnetic Starter
Solutions Guide
Featuring:
Schneider Electric NEMA Starters
Schneider Electric Type "S" NEMA starters and
Schneider Electric Telemecanique starters
Basic starters, enclosures, and other components
available from stock
Lead time: 1 to 3 days for most custom configurations
Schneider Electric Telemecanique Starters
Custom configurations include:
 Control transformers with
primary & secondary fuses
 HOA switches
 Pilot lights (100,000 hour LED)
 Phase monitors installed
 Many other common accessories
Job specific submittal data provided upon request
Also available upon request:
Soft starters - SSRV (Solid State Reduced Voltage)
Pump panels
Cooling tower panels
Compressor control panels
www.palmerdcs.com/magnetic-starters-HVAC-motor-starters/
Let us wow you in 3 minutes!
Learn more about what Palmer DCS can do for you….
Combination Starters
Schneider Electric
NEMA
Schneider Electric
http://www.palmerdcs.com/movie/ Telemecanique
People doing business with people.
Table of Contents
Magnetic Starter Quick-Estimator …………………………………………………………………………….……. .
A-2
Magnetic Starters Submittal Data ……………………………………………………………………………………
Magnetic Starters Part Numbering Configurator ……………………………………………….…………………..
B-1
B-2
Magnetic Starters Feature Selection ……..…………………………………………………….……………….…..
Magnetic Starters Pricing, 460V ……...………………………………………………………….………………….
Magnetic Starters Pricing, 208/230V ...………………………………………………………….……………….….
Magnetic Starters Pricing, Single-Phase ……………………………………………………….……………….….
C-1
C-2
C-3
C-4
Combination Magnetic Starters Feature Selection ……..…………………………………….…………….……..
Combination Magnetic Starters Pricing, 460V ……...………………………………………….………….……….
Combination Magnetic Starters Pricing, 208/230V ...………………………………………………….……….….
D-1
D-2
D-3
Multispeed Magnetic Starters Feature Selection ...…………………………………………….………………….
Multispeed Magnetic Starters Pricing, 2-Winding and 1-Winding ….………………………….…………………
Multispeed Magnetic Starters Pricing, Accessories ….……………………………………….……………………
E-1
E-2
E-3
NEMA Magnetic Starters Submittal Data ………………………………………………………………………..….
NEMA Magnetic Starters Part Numbering System …………………………………………………………….…..
F-1
F-2
NEMA Magnetic Starters Feature Selection ……..…………………………………………………………….…..
NEMA Magnetic Starters Pricing, 460V ……...………………………………………………………………….….
NEMA Magnetic Starters Pricing, 208/230V ...……………………………………………………………………..
NEMA Magnetic Starters Pricing, Single-Phase .…………………………………………………………………..
G-1
G-2
G-3
G-4
NEMA Combination Magnetic Starters Feature Selection ……..…………………………………………………
NEMA Combination Magnetic Starters Pricing, 460V ……...……………………………………………………..
NEMA Combination Magnetic Starters Pricing, 208/230V ...……………………………………………………..
H-1
H-2
H-3
NEMA Circuit Breaker Combination Magnetic Starters Feature Selection ………………………………………
NEMA Circuit Breaker Combination Magnetic Starters Pricing, 460V …………………………………………..
NEMA Circuit Breaker Combination Magnetic Starters Pricing, 208/230V ……………………………………...
I-1
I-2
I-3
NEMA Multispeed Magnetic Starters Feature Selection .………………………………….………………..…….
NEMA Multispeed Magnetic Starters Pricing, 2-Winding and 1-Winding ….………………………….…………
NEMA Multispeed Magnetic Starters Pricing, Accessories ………………………………….……………………
J-1
J-2
J-3
NEMA Manual Starters Pricing and Features ………………………………………………………………………
NEMA Manual Starters Dimensions ……………….………………………………………………………………...
K-1
K-2
Safety Switches, General and Heavy Duty Feature Selection ……………………………………………………….. M-1
Safety Switches, General and Heavy Duty, Pricing ...........………………………………………………………..
M-2
Safety Switches, General and Heavy Duty, Accessories ………………………………………………………….
M-3
Motor Amps Reference Chart ………………………………………………………………………………………...
Reference Data/Glossary ……………………………………………………………………………………………..
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
R-1
R-2
A-1
JUL -14
Magnetic Starter Quick-Estimator
List pricing with control transformer and HOA switch installed:
Use this page for a quick means of pricing the most common indoor and outdoor starter configurations with a control transformer and HOA.
Common accessories are also listed. For any other custom configurations, use the main catalog.
Schneider Electric Telemecanique Enclosed Three-Phase Starters with CPT/HOA
Three-Phase
Non-combination Starter
Combination Fusible Disconnect Starter
Size
Max HP
List Price
List Price
208V 230V 460V
NEMA 1
NEMA 3R
NEMA 1
NEMA 3R
2
2
5
D09
$ 509
$ 657
$ 1,056
$ 1,258
3
3
7.5
D12
$ 534
$ 711
$ 1,100
$ 1,301
5
5
10
D18
$ 563
$ 736
$ 1,100
$ 1,301
7.5
7.5
15
D25
$ 607
$ 746
$ 1,275
$ 1,398
10
10
20
D32
$ 712
$ 925
$ 1,519
$ 1,808
25/30
D40
$ 864
$ 1,080
$ 1,678
$ 2,002
15
15
40
D50
$ 988
$ 1,204
$ 2,629
$ 2,997
20
20
50
D65
$ 1,113
$ 1,400
$ 2,752
$ 3,172
Note: All Telemecanique starters include (1) N.O. and (1) N.C. auxiliary contacts as standard.
Combination starter pricing includes (3) class J fuses of appropriate rating installed in fuse clips.
Options for above:
One Pilot Light
One Pilot Light (push-to-test)
Two Pilot Lights (on and off)
Auxiliary Contacts, two
Auxiliary Contacts, four
Time Mark 257 series phase monitor
$ 119
$ 207
$ 235
$ 35
$ 70
$ 360
Schneider Electric Type "S" NEMA Enclosed Three-Phase Starters with CPT/HOA
Three-Phase
Non-combination Starter - NEMA
Combination Fusible Disconnect Starter - NEMA
NEMA
Max HP
List Price
List Price
Size
208V 230V 460V
NEMA 1
NEMA 3R
NEMA 1
NEMA 3R
1.5
1.5
2
00
$ 641
$ 729
$ 1,233
$ 1,440
3
3
5
0
$ 690
$ 760
$ 1,233
$ 1,440
7.5
7.5
10
1
$ 736
$ 806
$ 1,293
$ 1,499
10
15
25
2
$ 1,173
$ 1,339
$ 1,923
$ 2,224
25
30
50
3
$ 1,800
$ 1,982
$ 3,114
$ 3,506
Note: All NEMA starters include (1) N.O. auxiliary contact as standard.
Combination starter pricing includes (3) class J fuses of appropriate rating installed in fuse clips.
Options for NEMA starters:
One Pilot Light
One Pilot Light (push-to-test)
Two Pilot Lights (on and off)
Auxiliary Contacts, one pair (left side)
Auxiliary Contacts, second pair (right side)
Time Mark 257 series phase monitor
$ 119
$ 207
$ 235
$ 79
$ 79
$ 360
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
A-2
JUL
JAN-13
-14
Magnetic Starters
Submittal Data
Schneider Electric Telemecanique Magnetic Starters










D-Line overload relay features:
Adjustable dial calibrated in motor fullload amps. Dial is located under a clear
plastic hinged cover that may be wire
sealed after proper setting
Overloads have built-in bimetal heaters
with a mechanism that advances the trip
setpoint approximately 25% under phase
loss conditions.
Overloads are ambient compensated.
Overloads have a N.O. contact that
closes when tripped for connection to a
remote alarm (standard).
A trip TEST button is provided to test trip
function (press with small screwdriver).
Schneider Electric "D-Line" contactors and overload relays
are the largest selling line of contactors and starters in the
world.
All starters are UL listed.
Starters are rated for 55°C ambient temperature without
de-rating.
Overload relay with adjustable dial and built-in heaters is
provided with manual reset and external reset pushbutton;
see overload features below.
Available in NEMA 1, 3R, 4 or 12 enclosures.
Available with factory wired control transformer with 24V or
120V secondary. All control transformers have primary and
secondary fusing standard.
Control transformers are Micron Impervitran™ fully epoxy
encapsulated type.
One N.O. and one N.C. auxiliary contacts standard
on sizes D09-D150.
Additional auxiliary contacts available for top or side
mounting.
All starters may be wired for under voltage protection or
under voltage release.
Visual Trip indicator - a yellow flag pops
up in this window when tripped.
Manual reset button - may be set for
manual or auto reset.
N.C. trip contact for connection to
contactor coil.
Standard overloads have Class 10 trip
characteristic for best motor protection
for most loads, i.e. trips in less than 10
seconds under locked-rotor conditions.
Optional Class 20 overloads are
available in all sizes larger than 4 amps
at no extra charge. Specify Class 20
overloads for high inertia loads.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
B-1
JUL-14
Magnetic Starters
Part Numbering Configurator
Coil Code
Contactor
D Line
D09
D12
D18
D25
D32
D40
D50
D65
D80
D115
D150
F-Line
F115
F150
F185
F265
F330
F400
F500
F630
F780
Add "B" suffix for
single phase input
Fusible Disconnect
F61
208-600V
F62
208-600V
F63
208-600V
F64
208-600V
Control Transformer
Code Primary Secondary
XA
208V
120V
XB
230V
120V
XC
460V
120V
XD
575V
120V
XE
230V
24V
XF
460V
24V
XH
208V
24V
XI
120V
24V
XJ
277V
120V
XK
277V
24V
Configuration
Blank
FVR
M2W
M2WH
M1W
M1WH
RVAT
RVYD
RVPW
P
DP
Combination Starter
AC coils:
24, 120, 208, 230, 277,
460, 575
D09 - _ _ _ _ -
XC
30A CL. J
60A CL. J
100A CL. J
200A CL. J
Non-Fusible Disconnect
Available on special order
Motor Circuit Protector
See NEMA rated starters
Blank = none
-
4A
Example
Part Number: D09-XC-4A-G7 describes a
D09 starter with 460/120V control transformer,
2.5-4 amp Class 10 overload, NEMA 1 general
purpose indoor enclosure, and Hand-Off-Auto
switch factory installed.
D Line
1A
0.63-1
1.6A 1-1.6
2.5A 1.6-2.5
4A
2.5-4
6A
4-6
8A
5.5-8
10A 7-10
13A 9-13
18A 12-18
24A 17-24
32A 23-32
40A 30-40
50A 37-50
65A 48-65
70A 55-70
80A 63-80
100A 60-100
150A 90-150
Pilot Devices
Full Voltage
1 Pilot light
2 On/Off Pilot lights
3 Start-Stop PB's
4 Pilot light, push-to-test
6 Off-On switch
7 Hand-Off-Auto switch
7H Heavy Duty HOA
0 None
Multispeed
7 HOA + High-Off
Low switches
8 Auto-Off-Low-High
switch w/ decel timer
2 Hi & Low Pilot Lights
3 Hi/Low/Off Pilot lights
0 None
- ____ - G
Overload Relay
= Full Voltage
= Full Voltage Reversing
= Multispeed 2 Wdg, Const/Variable Torque
= Multispeed 2 Wdg, Const HP
= Multispeed 1 Wdg, Const/Variable Torque
= Multispeed 1 Wdg, Const HP
= Reduced Voltage Auto-Transformer
= Reduced Voltage wYe Delta
= Reduced Voltage Part Winding
= Pump Panel
= Duplex Pump Panel
F-Line .
50A 30-50
80A 48-80
150A 90-150
220A 132-220
300A 200-300
500A 300-500
630A 380-630
Note: Class 10 trip
time is standard. Class
20 trip available for
amps >= 4A.
Add 2 to code for Class 20
overload, i.e. 4A2, 4 amp
overload with Class 20
trip time
7
Enclosure
G = General Purpose
(NEMA 1)
D = Dust tight (NEMA 12)
W = Water tight (NEMA 4)
C = Water tight/Corrosion
Resistant (NEMA 4X)
R = Rain tight (NEMA 3R)
E = Explosion proof
N = No enclosure
(open device)
Options
Many other options are
available; please contact
Palmer DCS’ office.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
B-2
JUL-14
Magnetic Starters Feature Selection
Schneider Electric Telemecanique Magnetic Starters
These full voltage starters are manufactured in accordance with IEC
standards and are UL listed.
Schneider Electric "D-Line" contactors and overload relays are the largest
selling line in the world.
We supply IEC style starters with an adjustable Schneider Electric
Telemecanique bimetal overload relay as standard, available with Class 10
or Class 20 trip characteristics. The overload relay has an adjustable dial,
built-in heaters and is provided with manual reset and an external reset
pushbutton.
NEMA 1 indoor
Included
120V
24V
Customer:
HOA
Start/Stop
Off/On
(2no)
(1no/1nc)
NEMA 3R/12
Other _____
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Hand-Off-Auto selector switch (standard)
Start-Stop pushbuttons
Off-On selector switch
Aux. Contact module w/ two extra contacts (Left side-mount)
(2 N.O. contacts, or 1 open and 1 closed)
(2no)
(1no/1nc)
Project:
(4no)
Aux. Contact module w/ 2 or 4 extra contacts (Top-mount)
(all N.O. contacts, or combination of open and closed)
(2no/2nc)
Phase Monitor - Time-Mark 257 series
Phase Loss/under voltage /reversal with normal and tripped LEDs
On (red)
Off (grn)
Other
Pilot Lights
24-120V Protected LED type 100,000 hours life
Option for push-to-test lamps if required
Push-to-test
All accessories mounted and wired at no charge.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
C-1
JUL-14
Magnetic Starters Pricing, 460V
460V Telemecanique Magnetic Starters
460V HP
3 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 4
Water tight
-W
NEMA 12
Dust tight
-D
$ 224
$ 352
$ 474
$ 420
Catalog Number
Amp
Range
D09-  - 1.6A- 
1 - 1.6
D09-  - 2.5A- 
1.6 – 2.5
D09-  - 4A- 
2.5 - 4
D09-  - 6A- 
D09-  - 8A- 
D12-  - 13A- 
D18-  - 18A- 
D25-  - 24A- 
D32-  - 32A- 
4–6
5.5 – 8
9 – 13
12 – 18
17 – 24
23 – 32
$ 249
$ 278
$ 322
$ 427
$ 406
$ 431
$ 441
$ 620
$ 513
$ 537
$ 548
$ 726
$ 460
$ 485
$ 495
$ 674
D40-  - 40A- 
30 – 40
$ 490
$ 686
$ 793
$ 739
D50-  - 65A- 
D65-  - 65A- 
48 - 65
48 – 65
D115-  - 100A- 
60 – 100
$ 614
$ 739
$ 1,416
$ 810
$ 1,006
$ 1,834
$ 917
$ 1,113
$ 2,013
$ 863
$ 1,059
$ 2,013
D150-  - 150A- 
90 – 150
$ 1,923
$ 2,699
$ 2,875
$ 2,875
Control Transformer
Price
Rating
Adder
$ 217
50 VA
$ 306
100 VA
441
250 VA
 Specify coil voltage: 24, 120, or 460, or Control Transformer: XC = 460/120V or XF = 460/24V. Use applicable price
adder for control transformer.
 Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7 for HOA.
Accessories are listed on Page C-2.
See Page B-2 for an example.
Accessories
Cat. No. Suffix
Price
7
$ 68
Heavy-Duty Oil Tight HOA (NEMA 3R, 4, 12)
7H
$ 88
Start-Stop Pushbuttons
3
$ 88
HOA (NEMA 1 only)
Off-On Switch
6
2 N.O. = DNS20
Side Mount Extra Aux. Contacts
(block of two, left side mount only)
N.O. / N.C. = DNS11
2 N.O. = DN20
Top Mount Extra Aux. Contacts
(block of two)
N.O. / N.C. = DN11
4 N.O. = DN40
Top Mount Extra Aux. Contacts
(block of four)
2 N.O./ 2 N.C. = DN22
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with
PM
normal and tripped LEDs
Pilot Light
1
24-120V protected LED type 100,000 hours life
On and Off Pilot Lights
2
24-120V Protected LED type 100,000 hours life
Pilot Light, push-to-test
4
24-120V Protected LED type 100,000 hours life
All accessories mounted and wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
$ 88
$ 35
$ 35
$ 70
$ 360
$ 119
$ 235
$ 207
C-2
JUL-14
Magnetic Starters Pricing, 208/230V
208V Telemecanique Magnetic Starters
208V HP
3 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
Catalog Number
Amp
Range
D09-  - 2.5A- 
D09-  - 4A- 
D09-  - 6A- 
1.6 – 2.5
2.5 – 4
4–6
D09-  - 8A- 
5.5 – 8
D12-  - 13A- 
D18-  - 18A- 
D25-  - 24A- 
D32-  - 32A- 
D50-  - 50A- 
D65-  - 65A- 
D80-  - 80A- 
D115-  - 100A- 
D150-  - 150A- 
F185-  - 150A- 
9 – 13
12 – 18
17 – 24
23 – 32
37 - 50
48 – 65
63 – 80
60 – 100
90 – 150
90 – 150
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 4
Water tight
-W
NEMA 12
Dust tight
-D
$ 224
$ 352
$ 474
$ 420
$ 249
$ 278
$ 322
$ 427
$ 614
$ 739
$ 1,050
$ 1,416
$ 1,923
$ 2,475
$ 406
$ 431
$ 441
$ 620
$ 810
$ 1,006
$ 1,318
$ 1,834
$ 2,699
$ 3,134
$ 495
$ 537
$ 548
$ 726
$ 917
$ 1,113
$ 1,425
$ 2,013
$ 2,875
$ 3,313
$ 460
$ 485
$ 495
$ 674
$ 863
$ 1,059
$ 1,370
$ 2,013
$ 2,875
$ 3,313
Control Transformer
Price
Rating
adder
$ 217
50 VA
$ 306
100 VA
$ 441
250 VA
 Specify coil voltage: 24, 120, or 208, or Control Transformer: XA = 208/120V or XH = 208/24V. Use applicable price
adder for control transformer.

Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7 for HOA.
Accessories are listed on Page C-2.
See Page B-2 for an example.

230V Telemecanique Magnetic Starters
230V HP
3 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
Catalog Number
Amp
Range
D09-  - 2.5A- 
1.6 – 2.5
D09-  - 4A- 
2.5 - 4
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 4
Water tight
-W
NEMA 12
Dust tight
-D
Control Transformer
Price
Rating
adder
$ 224
$ 352
$ 474
$ 420
D09-  -6A- 
4-6
D09-  - 8A- 
5.5 – 8
$ 217
50 VA
D12-  - 10A- 
7 – 10
$ 249
$ 406
$ 513
$ 460
D18-  - 18A- 
12 – 18
$ 278
$ 431
$ 537
$ 485
D25-  - 24A- 
17 – 24
$ 322
$ 441
$ 548
$ 495
D32-  - 32A- 
23 – 32
$ 427
$ 620
$ 726
$ 674
D50-  - 50A- 
37 – 50
$ 614
$ 810
$ 917
$ 863
D65-  - 65A- 
48 – 65
$ 739
$ 1,006
$ 1,113
$ 1,059
$ 306
100 VA
D80-  - 80A- 
63 – 80
$ 1,050
$ 1,318
$ 1,425
$ 1,370
D115-  - 100A- 
60 – 100
$ 1,416
$ 1,834
$ 2,013
$ 2,013
D115-  - 150A- 
90 – 115
$ 441
250 VA
D150-  - 150A- 
90 – 150
$ 1,923
$ 2,699
$ 2,875
$ 2,875
 Specify coil voltage: 24, 120, or 230, or Control Transformer: XB = 230/120V or XE = 230/24V. Use applicable price
adder for control transformer.
 Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7 for HOA.
Accessories are listed on Page C-2.
See Page B-2 for an example.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
C-3
JUL-14
Magnetic Starters Pricing, Single-Phase
115V SINGLE PHASE Telemecanique Magnetic Starters
115V HP
1 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
7 – 10
NEMA 1
Indoor
-G
$ 224
NEMA 3R
Rain tight
-R
$ 352
NEMA 4
Water tight
-W
$ 474
NEMA 12
Dust tight
-D
$ 420
D18B-  - 18A- 
12 – 18
$ 278
$ 431
$ 537
$ 485
D25B-  - 24A- 
D32B-  - 24A- 
D40B-  - 40A- 
D65B-  - 65A- 
D80B-  - 80A- 
17 – 24
17 – 24
30 – 40
48 – 65
63 – 80
$ 322
$ 427
$ 490
$ 739
$ 1,050
$ 441
$ 620
$ 686
$ 1.006
$ 1,318
$ 548
$ 726
$ 793
$ 1,113
$ 1,425
$ 495
$ 674
$ 739
$ 1,059
$ 1,370
Catalog Number
Amp
Range
D09B-  - 10A- 
Control Transformer
Price
Rating
adder
$ 217
50 VA
$ 306
100VA

 Specify coil voltage: 24 or 120, or Control Transformer: XI = 120/24V. Use applicable price adder for control transformer.
Note: Control Transformer not needed for 120V coil.
 Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7 for HOA.
Accessories are listed on Page C-2.
See Page B-2 for an example.
230V SINGLE PHASE Telemecanique Magnetic Starters
230V HP
1 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
Catalog Number
Amp
Range
D09B-  - 6A- 
4–6
D09B-  - 8A- 
5.5 – 8
D12B-  - 10A- 
D12B-  - 13A- 
D18B-  - 18A- 
D32B-  - 32A- 
D50B-  - 40A- 
D65B-  - 50A- 
D80B-  - 80A- 
7 – 10
9 – 13
12 – 18
23 – 32
30 – 40
37 – 50
63 – 80
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 4
Water tight
-W
NEMA 12
Dust tight
-D
$ 224
$ 352
$ 474
$ 420
$ 249
$ 406
$ 513
$ 460
$ 278
$ 427
$ 614
$ 739
$ 1,050
$ 431
$ 620
$ 810
$ 1,006
$ 1,318
$ 537
$ 726
$ 917
$ 1,113
$ 1,425
$ 485
$ 674
$ 863
$ 1,059
$ 1,370
Control Transformer
Price
Rating
adder
$ 217
50 VA
$ 306
100VA

 Specify coil voltage: 24, 120 or 230, or Control Transformer: XB=230/120V or XE = 230/24V.
Use applicable price adder for control transformer.
 Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7 for HOA.
Accessories are listed on Page C-2.
See Page B-2 for an example.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
C-4
JUL-14
Combination Magnetic Starters Feature Selection
Schneider Electric Telemecanique Combination Magnetic Starters
Fusible Combination Type with Class J Fuses
These combination starters combine the requirements of motor overload and short circuit
protection into one package. These starters are manufactured in accordance with IEC
standards and are UL listed.
We supply combination starters with an adjustable Schneider Electric Telemecanique bimetallic
overload relay as standard, available with Class 10 or Class 20 trip characteristics.
These combination starters include a main 600V disconnect switch with fuse clips for Class J
fuses. Main power fuses are not included unless noted below
NEMA 1 indoor
NEMA 3R/12
Class J fuse clips (standard)
Included
120V
24V
Customer:
HOA
Start/Stop
Off/On
(2N.O.)
(1N.O./1N.C.)
Other _____
Class J power fuses included
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Hand-Off-Auto selector switch (standard)
Start-Stop pushbuttons
Off-On selector switch
Auxiliary Contact module with two extra contacts (left sidemount)
(2 N.O. contacts, or 1 open and 1 closed)
(2no)
(1N.O./1N.C.)
Project:
(4N.O.)
Auxiliary Contact module w/ 2 or 4 extra contacts (Top-mount)
(all N.O. contacts, or combination of open and closed)
(2N.O./2N.C.)
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with normal and tripped LEDs
On (red)
Off (grn)
Other
Push-to-test
Pilot Lights
24-120V Protected LED type 100,000 hours life
Option for push-to-test lamps if required
Spare Fuses
(3) Class J spare line fuses supplied loose
All accessories mounted and wired at no charge.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
D-1
JUL-14
Combination Magnetic Starters Pricing, 460V
460V Telemecanique Combination Magnetic Starters with Fusible Disconnect (Class J fuse clips)
460V HP
3 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
Catalog Number
Amp Range
D18-  - 1.6A- F61 - 
1 - 1.6
D18-  - 2.5A- F61 - 
1.6 – 2.5
D18-  - 4A- F61 - 
2.5 – 4
D18-  - 6A- F61 - 
D18-  - 8A- F61 - 
D18-  - 13A- F61 - 
D18-  - 18A- F61 - 
D25-  - 24A- F61 - 
D32-  - 32A- F62 - 
4–6
5.5 – 8
9 – 13
12 – 18
17 – 24
23 – 32
D40-  - 40A- F62 - 
30 – 40
Fuse Clip
Rating
NEMA 1
Indoor
-G
NEMA 3R
Outdoor
-R
NEMA 12
Dust tight
-D
$ 691
$ 893
$ 893
30 amp
Class J
Control Transformer
Price
Rating
Adder
$ 217
50 VA
$ 306
D50-  - 65A- F63 - 
48 - 55
$ 1,995
$ 2,363
$ 2,363
100 amp
D65-  - 65A- F63 - 
48 – 65
$ 2,118
$ 2,538
$ 2,538
Class J
D115-  - 100A- F63 - 
60 – 100
$ 2,538
$ 2,765
$ 2,765
D115-  - 100A- F64 - 
60 – 100
$ 3,483
$ 4,130
$ 4,130
$ 441
200 amp
Class J
D150-  - 150A- F64 - 
90 – 150
$ 3,990
$ 5,145
$ 5,145
 Specify coil voltage: 24, 120, or 460; or Control Transformer: XC=460/120V, or XF=460/24V (use applicable price adder)
100 VA

60 amp
Class J
$ 735
$ 936
$ 963
$ 910
$ 1,094
$ 1,033
$ 1,383
$ 1,033
$ 1,383
$ 1,164
$ 1,488
$ 1,488
250 VA
Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
See Page B-2 for an example.
Accessories
Heavy-Duty Oil Tight HOA
Start-Stop Pushbuttons
Off-On Switch
Side Mount Extra Auxiliary Contacts
(block of two, left side mount only)
Top Mount Extra Auxiliary Contacts
(block of two)
Top Mount Extra Auxiliary Contacts
(block of four)
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal
With normal and tripped LEDs
Pilot Light
24-120V protected LED type 100,000 hours life
On and Off Pilot Lights
24-120V protected LED type 100,000 hours life
Cat. No. Suffix
Price
7H
3
$ 88
$ 88
6
2 N.O. = DNS20
N.O. / N.C. = DNS11
2 N.O. = DN20
N.O./N.C. = DN11
4 N.O. = DN40
2 N.O./2 N.C. = DN22
$ 88
PM
$ 360
1
$ 119
2
$ 235
Pilot Light, push-to-test
4
24-120V Protected LED type 100,000 hours life
Class J Power Fuses, Qty. 3, 600V Rated
1/2-15HP @ 460V, 1/2-7.5HP @ 208/230V
20-30HP @ 460V, 10HP @ 208/230V
Fused
40-50HP @ 460V, 15-20HP @ 208/230V
60-100HP @ 460V, 30-50HP @ 208/230V
All accessories mounted and wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
$ 35
$ 35
$ 70
$ 207
$ 60
$ 120
$ 240
$ 480
D-2
JUL-14
Combination Magnetic Starters Pricing, 208/230V
208V Telemecanique Combination Magnetic Starters with Fusible Disconnect (Class J fuse clips)
208V HP
3 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
Catalog Number
Amp
Range
D18-  - 2.5A- F61- 
D18-  - 4A- F61- 
D18-  - 6A- F61- 
1.6 – 2.5
2.5 – 4
4–6
D18-  - 8A- F61- 
5.5 – 8
Fuse
Clip
Rating
30 amp
Class J
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
$ 691
$ 893
$ 893
Control Transformer
Price
Rating
adder
$ 217
D18  - 13A- F61- 
9 – 13
$ 735
$ 936
$ 936
D18-  - 18A- F61- 
12 – 18
D32-  - 24A- F62- 
17 – 24
$ 1,383
$ 1,383
$ 910
60 amp
Class J
D40-  - 32A- F62- 
23 – 32
$ 1,094
$ 1,488
$ 1,488
D50-  - 50A- F63- 
37 – 50
$ 306
$ 2,118
$ 2,538
$ 2,538
100 amp
D65-  - 65A- F63- 
48 – 65
Class J
D115-  - 100A- F63- 
63 – 80
$ 2,538
$ 2,765
$ 2,765
D115-  - 100A- F64- 
60 – 100
$ 3,483
$ 4,130
$ 4,130
200 amp
$ 441
Class J
D150-  - 150A- F64- 
90 – 150
$ 3,990
$ 5,145
$ 5,145
 Specify coil voltage: 24, 120, or 208,
or Control Transformer: XA = 208/120 or XH = 208/24V. Use applicable price adder for control transformer.
 Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
50 VA
100 VA
250 VA
Accessories are listed on Page D-2.
See Page B-2 for an example.

230V Telemecanique Combination Magnetic Starters with Fusible Disconnect (Class J fuse clips)
230V HP
3 Phase
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
Catalog Number
Amp
Range
D18-  - 2.5A- F61- 
1.6 – 2.5
D18-  - 4A- F61- 
2.5 - 4
Fuse
Clip
Rating
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
Control Transformer
Price
Rating
adder
$ 691
$ 893
$ 893
30 amp
D18-  -6A- F61 - 
4-6
Class J
$ 217
50 VA
D18-  - 8A- F61 - 
5.5 – 8
D18-  - 10A- F61 - 
7 – 10
$ 735
$ 936
$ 936
D18-  - 18A- F61 - 
12 – 18
D32-  - 24A- F62 - 
17 – 24
$ 1,094
$ 1,383
$ 1,383
60 amp
D32-  - 32A- F62 - 
23 – 32
Class J
D50-  - 50A- F62 - 
37 – 50
$ 1,960
$ 2,310
$ 2,310
$ 306
100 VA
D65-  - 65A- F63 - 
48 – 65
$ 2,118
$ 2,538
$ 2,538
100 amp
Class J
D115-  - 100A- F63 - 
60 – 100
$ 2,538
$ 2,765
$ 2,765
D115-  - 100A- F64 - 
60 – 100
$ 441
250 VA
$ 3,483
$ 4,130
$ 4,130
200 amp
D115-  - 150A- F64 - 
90 – 115
Class J
D150-  - 150A- F64 - 
90 – 150
$ 3,990
$ 5,145
$ 5,145
 Specify coil voltage: 24, 120, or 230, or Control Transformer: XB = 230/120V or XE = 230/24V. Use applicable price adder
for control transformer.
 Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
Accessories are listed on Page D-2.
See Page B-2 for an example.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
D-3
JUL-14
Multispeed Magnetic Starters Feature Selection
Schneider Electric Telemecanique Multispeed Starters
These full voltage starters are manufactured in accordance with IEC
standards and are UL listed.
Schneider Electric "D-Line" contactors and overload relays are the largest
selling line in the world.
Starters include (2) adjustable Schneider Electric Telemecanique bimetal
overload relays as standard, available with Class 10 or Class 20 trip
characteristics. The overload relays have an adjustable dial, built-in
heaters and are provided with manual reset and an external reset
pushbutton.
D09 - D32 starters include (1) N.O. auxiliary contact standard.
D40 - D150 starters include (1) N.O. and (1) N.C. auxiliary contact
standard.
F185 - F330 starters include (1) N.O. auxiliary contact standard.
NEMA 1 indoor
Included
120V
24V
Customer:
AOLH
HOA and
HOL
NEMA 3R/12
Other _____
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Auto-Off-Low-High selector switch (standard)
Hand-Off-Auto and High-Off-Low switches
Automatic decelerating timer (standard)
Multispeed motors should never be rapidly switched from high to
low speed, or damage to the motor or driven equipment may
result. Addition of a timer delays energizing of the motor in low
speed after high speed operation.
Automatic accelerating timer
This option adds two relays and two timers to ensure that the
motor always starts at low speed. When high speed is selected,
the relays start the motor on low and then automatically switch to
high speed after an adjustable time. These are commonly used
with high inertia fans because starting stress on the motor is
substantially reduced resulting in longer motor life. The
decelerating timer option is usually used in conjunction to allow
completely automatic control.
Project:
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with normal and tripped LEDs
High (red)
Low (yellow)
Off (green)
Other
Pilot Lights
24-120V protected LED type 100,000 hours life
Option for push-to-test lamps if required
Push-to-test
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
E-1
JUL-14
Multispeed Magnetic Starters Pricing, 2-Winding and 1-Winding
Telemecanique Multispeed Starters - 2 SEPARATE WINDINGS
Maximum HP Ratings
208V
230V
460V
2
3
5
7.5
10
10
15
20
30
30
40
50
60
75
2
3
5
7.5
10
10
15
20
30
40
50
60
75
100
5
7.5
10
15
20
30
40
50
60
75
100
125
150
200
2-Speed
2-Winding
Catalog Number
D09-M2W-  - # - 
D12-M2W-  - # - 
D18-M2W-  - # - 
D25-M2W-  - # - 
D32-M2W-  - # - 
D40-M2W-  - # - 
D50-M2W-  - # - 
D65-M2W-  - # - 
D80-M2W-  - # - 
D115-M2W-  - # - 
D150-M2W-  - # - 
F185-M2W-  - # - 
F265-M2W-  - # - 
F330-M2W-  - # - 
NEMA 1
Indoor
-G
$ 595
$ 665
$ 733
$ 802
$ 1,110
$ 1,423
$ 1,617
$ 1,811
$ 2,200
$ 4,823
$ 5,292
$ 8,190
$ 10,379
$ 12,418
NEMA 3R
Rain tight
-R
$ 718
$ 823
$ 924
$ 1,010
$ 1,293
$ 1,617
$ 1,974
$ 2,254
$ 2,816
$ 5,581
$ 6,536
$ 9,240
$ 11,457
$ 15,292
NEMA 4
Water tight
-W
$ 1,206
$ 1,313
$ 1,411
$ 1,633
$ 2,357
$ 2,483
$ 2,676
$ 2,870
$ 3,519
$ 7,553
$ 8,306
$ 10,453
$ 12,210
$ 16,044
NEMA 12
Dust tight
-D
$ 718
$ 823
$ 924
$ 1,010
$ 1,293
$ 1,617
$ 1,974
$ 2,254
$ 2,816
$ 5,581
$ 6,536
$ 9,240
$ 11,457
$ 15,292
Control Transformer
Price
Rating
Adder
$ 217
50 VA
$ 306
100 VA
$ 441
250 VA
 Specify coil voltage: 24, 120, or 460; or Control Transformer: XC = 460/120V, XF = 460/24V, XB = 230/120V,
XE = 230/24V, XA = 208/120V, XH = 208/24V. Use applicable price adder for control transformer.
#

Specify overload relays, high speed and low speed. See part numbering sheet for amp ranges and codes.
Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories.
See Page B-2 for an example
Telemecanique Multispeed Starters - 1 RECONNECTABLE WINDING
Maximum HP Ratings
208V
230V
460V
2
3
5
7.5
10
10
15
20
30
30
40
50
60
75
2
3
5
7.5
10
10
15
20
30
40
50
60
75
100
5
7.5
10
15
20
30
40
50
60
75
100
125
150
200
2-Speed
1-Winding
Catalog Number
D09-M1W-  - # - 
D12-M1W-  - # - 
D18-M1W-  - # - 
D25-M1W-  - # - 
D32-M1W-  - # - 
D40-M1W-  - # - 
D50-M1W-  - # - 
D65-M1W-  - # - 
D80-M1W-  - # - 
D115-M1W-  - # - 
D150-M1W-  - # - 
F185-M1W-  - # - 
F265-M1W-  - # - 
F330-M1W-  - # - 
NEMA 1
Indoor
-G
$ 840
$ 928
$ 1,005
$ 1,078
$ 1,447
$ 1,916
$ 2,153
$ 2,391
$ 2,865
$ 6,358
$ 7,502
$ 10,955
$ 13,783
$ 14,828
NEMA 3R
Rain tight
-R
$ 1,012
$ 1,103
$ 1,195
$ 1,269
$ 1,650
$ 2,035
$ 2,510
$ 2,833
$ 3,481
$ 7,928
$ 8,722
$ 12,353
$ 15,323
$ 16,356
NEMA 4
Water tight
-W
$ 1,451
$ 1,558
$ 1,678
$ 1,743
$ 2,826
$ 2,975
$ 3,213
$ 3,449
$ 4,351
$ 8,509
$ 9,671
$ 12,695
$ 15,169
$ 19,898
NEMA 12
Dust tight
-D
$ 1,012
$ 1,103
$ 1,195
$ 1,269
$ 1,650
$ 2,035
$ 2,510
$ 2,833
$ 3,481
$ 7,928
$ 8,722
$ 12,353
$ 15,323
$ 16,356
Control Transformer
Price
Rating
Adder
$ 217
50 VA
$ 306
100 VA
$ 441
250 VA
 Specify coil voltage: 24, 120, or 460; or Control Transformer: XC = 460/120V, XF = 460/24V, XB = 230/120V,
XE = 230/24V, XA = 208/120V, XH = 208/24V. Use applicable price adder for control transformer.
#

Specify overload relays, high speed and low speed. See part numbering sheet for amp ranges and codes.
Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories.
See Page B-2 for an example
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
E-2
JUL-14
Multispeed Magnetic Starters Pricing, Accessories
Accessories
Cat. No. Suffix
Price
HOA and High-Off-Low switches
7
$ 176
Automatic decelerating timer
Auto-Off-Low-High selector switch and
decelerating timer
Side Mount Extra Auxiliary Contacts
(block of two, left side mount only)
Top Mount Extra Auxiliary Contacts
(block of two)
Top Mount Extra Auxiliary Contacts
(block of four)
9
$ 219
8
$ 307
Automatic accelerating timer
2 N.O. = DNS20
N.O./N.C. = DNS11
2 N.O. = DN20
N.O./N.C. = DN11
4 N.O. = DN40
2 N.O./2 N.C. = DN22
$ 35
5
$ 656
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with
PM
normal and tripped LEDs
Pilot Lights (2), for high and low speed
indication
2
24-120V protected LED type 100,000 hours life
Pilot Lights (3), for high speed, low speed and
off indication
3
24-120V protected LED type 100,000 hours life
Pilot Light, push-to-test
4
24-120V protected LED type 100,000 hours life
All accessories mounted and wired at no charge.
Pilot light voltage must match coil voltage.
$ 35
$ 70
$ 360
$ 235
$ 350
$ 207
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
E-3
JUL-14
NEMA Magnetic Starters
Submittal Data
Schneider Electric NEMA Magnetic Starters










NEMA Motor LogicTM overload
relay features:
Overloads are solid state type with
single -phase sensitivity for phase
unbalance and phase loss protection.
Trips in 3 seconds under phase loss
conditions.
N.C. trip contact for connection to
contactor coil (optional N.O. trip
alarm contact available).
Overloads are ambient compensated.
Visual trip indicator - a yellow flag pops
up in this window when tripped.
Schneider Electric Type "S" NEMA starters are the standard of the
industry.
All starters are UL listed.
All units have Schneider Electric "Motor Logic" adjustable solidstate overload relay with adjustable dial - no heaters!
- Ambient compensated and self-powered
- Solid state phase unbalance and phase loss protection
- Trips in 3 seconds under phase loss condition
- Selectable class 10 or class 20
- Optional N.O. trip alarm contact available
Inspectable, replaceable contacts on all sizes (including Size 00).
Fully encapsulated coils.
Available in NEMA 1, 3R, 4, 4X, 7, 9 or 12 enclosures.
Available with factory wired control transformer with 24V or 120V
secondary. All control transformers have primary and secondary
fusing standard.
Control transformers are Micron Impervitran™ epoxy
encapsulated.
One N.O. auxiliary contact standard - additional field-convertible
auxiliary contacts are available.
All starters may be wired for under voltage protection or under
voltage release.
Power ON indicator when amps are
flowing into the motor.
Adjustable dial calibrated in motor
full-load amps. Dial is located under
a clear plastic hinged cover that may
be wire sealed after proper setting.
Standard overloads have Class 10
trip characteristic for best motor
protection for most loads, i.e. trips in
less than 10 seconds under locked
rotor conditions.
Switch on overload cover is
adjustable between Class 10 and
Class 20 for high inertia loads.
Manual reset button.
A trip TEST button is provided to test trip
function (press with small screwdriver).
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
F-1
JUL-14
NEMA Magnetic Starters
Part Numbering Configurator
Contactor
Coil Code
Type "S" NEMA Starters
S00
NEMA Size 00
S0
NEMA Size 0
S1
NEMA Size 1
S2
NEMA Size 2
S3
NEMA Size 3
S4
NEMA Size 4
S5
NEMA Size 5
S6
NEMA Size 6
S7
NEMA Size 7
AC coils:
24, 120, 208, 230, 277,
460, 575
Add "B" suffix for single
phase. Single-phase units
have one heater instead
of solid state overload.
S1
Control Transformer
Code Primary Secondary
XA
208V
120V
XB
230V
120V
XC
460V
120V
XD
575V
120V
XE
230V
24V
XF
460V
24V
XH
208V
24V
XI
120V
24V
XJ
277V
120V
XK
277V
24V
- ____ Configuration
Blank
FVR
M2W
M2WH
M1W
M1WH
RVAT
RVYD
RVPW
P
DP
Combination Starter
XC
Fusible Disconnect
F61
30A J
F62
60A J
F63
100A J
F64
200A J
Non-Fusible Disconnect
U61
20830A
U62
600V 60A
U63
100A
U64
200A
Motor Circuit Protector
B followed by MCP amps.
Multispeed
7 HOA + High-Off
Low switches
8 Auto-Off-Low-High
switch with decelerating
timer
2 Hi and Low pilot lights
3 Hi/Low/Off pilot lights
0 None
- 27A_ - _ _ _ _ - G
Overload Relay
= Full Voltage
= Full Voltage Reversing
= Multispeed 2 Wdg, Const/Variable Torque
= Multispeed 2 Wdg, Const HP
= Multispeed 1 Wdg, Const/Variable Torque
= Multispeed 1 Wdg, Const HP
= Reduced Voltage Auto-Transformer
= Reduced Voltage Wye Delta
= Reduced Voltage Part Winding
= Pump Panel
= Duplex Pump Panel
Pilot Devices
Full Voltage
1 Pilot light
2 On/Off Pilot lights
3 Start-Stop PB's
4 Pilot light, push-to-test
6 Off-On switch
7H Heavy Duty HOA
0 None
Motor Logic Solid State Overload
4.5A
1.5-4.5
9A
3-9
18A
6-18
27A
9-27
45A
15-45
90A
30-90
135A
45-135
270A
90-270
540A
180-540
810A
270-810
7
Enclosure
G = General Purpose
(NEMA 1)
D = Dust tight (NEMA 12)
W = Water tight (NEMA 4)
C = Water tight Corrosion
Resistant (NEMA 4X)
R = Rain tight (NEMA 3R)
E = Explosion proof
N = No enclosure
(open device)
Options
Example
Part Number: S1-XC-27A-G7H describes
a NEMA Size 1 starter with 460/120V control
transformer, 9-27 amp, Class 10/20 overload,
NEMA 1 general purpose indoor enclosure, with
Hand-Off-Auto switch factory installed.
Many other options are
available; please contact
Palmer DCS’ office.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
F-2
JUL-14
NEMA Magnetic Starters
Feature Selection
Schneider Electric Type "S" NEMA Magnetic
Starters
These full-voltage magnetic starters are manufactured in
accordance with NEMA standards and are UL listed. Schneider
Electric Type "S" NEMA starters are the standard of the industry.
We supply NEMA rated starters with an adjustable Schneider
Electric Motor LogicTM solid state overload relay as standard;
conventional overload blocks with heaters are available as an
option.
Solid state overloads provide superior motor protection for the same
price as conventional heaters. See Page F-1 submittal sheet on
NEMA type "S" motor starters for details on contactors and Motor
LogicTM overloads.
NEMA 1 indoor
Included
120V
24V
Customer:
HOA
Start/Stop
Off/On
NEMA 3R/12
Other _____
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Hand-Off-Auto selector switch (standard)
Start-Stop pushbuttons
Off-On selector switch
Aux. Contact module (left side)
1 N.O, 1 N.C., field convertible
Aux. Contact module (right side)
1 N.O., 1 N.C. field convertible
Overload Trip Alarm Contact
On solid state overload; closes on trip (field convertible to N.C.)
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with normal and tripped LEDs
Project:
On (red)
Off (grn)
Other
Pilot Lights
24-120V Protected LED type 100,000 hours life
Option for push-to-test lamps if required
Push-to-test
All accessories mounted & wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
G-1
JUL-14
NEMA Magnetic Starters
Pricing, 460V
460V Schneider Electric Type "S" NEMA Magnetic Starters
460V HP
3 Phase
1/2 - 2
3-5
7.5 - 10
15 - 25
30 - 50
60 - 100
Control Transformer
NEMA 1
NEMA 4
NEMA 3R
NEMA 12
Indoor
Water tight
Rain tight
Dust tight
Price
Rating
-R
-G
-W
-D
Adder
S00 -  - 4.5A- 
00
1.5 - 4.5 *
$ 322
$ 410
$ 490
$ 438
S0 -  - 9A- 
0
3-9*
$ 371
$ 441
$ 529
$ 476
$ 231
75 VA
S1 -  - 18A- 
1
6 - 18 *
$ 417
$ 487
$ 578
$ 525
S2 -  - 45A- 
2
15 - 45
$ 779
$ 945
$ 970
$ 970
$ 306
100VA
$ 441
S3 -  - 90A- 
3
30 - 90
$ 1,271
$ 1,453
$ 1,491
$ 1,491
250VA
S4 -  - 135A- 
4
45 – 135
$ 2,783
$ 3,448
$ 3,553
$ 3,553
$ 508
350VA
 Specify coil voltage: 24, 120, or 460, or Control Transformer: XC = 460/120V or XF = 460/24V. Use applicable price adder for control
transformer.
Catalog Number
NEMA Size
Amp Range

Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
*
Overloads noted with * have CTs so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example.
Accessories
Cat. No. Suffix
Price
Heavy-Duty Oil tight HOA
7H
$ 88
Start-Stop Pushbuttons
3
$ 88
Off-On Switch
6
Overload Trip Alarm Contact
AC04
on solid state overload (field convertible)
Aux. Contact module (left side)
SX8
1 N.O., 1 N.C., field convertible
Aux. Contact module (right side)
SX8
1 N.O., 1 N.C., field convertible
Phase Monitor
Time-Mark 257 series
PM
Phase loss/under voltage/reversal
w/ normal & tripped LED's
Pilot Light
1
24-120V protected LED type 100,000 hours life
On & Off Pilot Lights
2
24-120V protected LED type 100,000 hours life
Pilot Light, push-to-test
4
24-120V protected LED type 100,000 hours life
All accessories mounted and wired at no charge
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
$ 88
$ 42
$ 79
$ 79
$ 360
$ 119
$ 235
$ 207
G-2
JUL-14
NEMA Magnetic Starters
Pricing, 208/230V
208V Schneider Electric Type "S" NEMA Magnetic Starters
208V HP
3 Phase
1/2 - 3/4
1 - 1.5
2-3
5 - 7.5
10
15 - 25
30 - 40
Catalog Number
NEMA
Size
Amp
Range
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 4
Water tight
-W
NEMA 12
Dust tight
-D
Control Transformer
Price
Rating
Adder
S00 -  - 4.5A- 
00
1.5 - 4.5 *
$ 322
$ 410
$ 490
$ 438
S00 -  - 9A- 
00
3-9*
$ 231
75 VA
S0 -  - 18A- 
0
6 - 18 *
$ 371
$ 441
$ 529
$ 476
S1 -  - 27A- 
1
9 - 27 *
$ 417
$ 487
$ 578
$ 525
S2 -  - 45A- 
2
15 - 45
$ 779
$ 945
$ 970
$ 970
$ 306
100VA
S3 -  - 90A- 
3
30 - 90
$ 1,271
$ 1,453
$ 1,491
$ 1,491
$ 441
250VA
S4 -  - 135A- 
4
45 – 135
$ 2,783
$ 3,448
$ 3,553
$ 3.553
$ 508
350VA
 Specify coil voltage: 24, 120, or 208, or Control Transformer: XA = 208/120V or XH = 208/24V. Use applicable price adder
for control transformer.

Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
*
Overloads noted with * have CTs, so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example
230V Schneider Electric Type "S" NEMA Magnetic Starters
230V HP
3 Phase
1/2 - 1
1.5
2
3
5 - 7.5
10 - 15
20 - 30
40 - 50
Catalog Number
NEMA
Size
Amp
Range
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 4
Water tight
-W
NEMA 12
Dust tight
-D
Control Transformer
Price
Rating
Adder
S00 -  - 4.5A- 
00
1.5 - 4.5 *
$ 322
$ 410
$ 490
$ 438
S00 -  - 9A- 
00
3-9*
S0 -  - 9A- 
0
3-9*
$ 231
75 VA
$ 371
$ 441
$ 529
$ 476
S0 -  - 18A- 
0
6 - 18 *
S1 -  - 27A- 
1
9 - 27 *
$ 417
$ 487
$ 578
$ 525
S2 -  - 45A- 
2
15 - 45
$ 779
$ 945
$ 970
$ 970
$ 306
100VA
S3 -  - 90A- 
3
30 - 90
$ 1,271
$ 1,453
$ 1,491
$ 1,491
$ 441
250VA
S4 -  - 135A- 
4
45 – 135
$ 2,783
$ 3,448
$ 3,553
$ 3.553
$ 508
350VA
 Specify coil voltage: 24, 120, or 230, or Control Transformer: XB = 230/120V or XE = 230/24V. Use applicable price adder
for control transformer.

Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
*
Overloads noted with * have CTs, so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
G-3
JUL-14
NEMA Magnetic Starters
Pricing, Single-Phase
Schneider Electric Type "S" NEMA Magnetic Starters for SINGLE PHASE motors
115V HP
1 Phase
230V HP
1 Phase
Catalog Number
NEMA
Size
1
2
3
2
3
5
S0B -  - Bxxx - 
S1B -  - Bxxx - 
S1PB -  - Bxxx - 
0
1
1P
NEMA 1
Indoor
-G
$ 312
$ 355
$ 455
NEMA 3R
Rain tight
-R
$ 413
$ 459
$ 558
NEMA 4
Water tight
-W
$ 497
$ 550
$ 649
NEMA 12
Dust tight
-D
$ 448
$ 497
$ 600
Control Transformer
Price
Rating
Adder
$ 231
75 VA

 Specify coil voltage: 24, 120, or 230, or Control Transformer: XI = 120/24V or XE = 230/24V or XB = 230/120V. Use
applicable price adder for control transformer. Control transformer not needed for 115V motor with 120V coil; starter is wired
for line voltage control.

 Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA
Accessories are same as for 3 phase starters, except phase monitor is not applicable.
See Page F-2 for an example
Single-phase starters are provided with overload block with provision to accept ONE heater element.
Select heater based on motor amps from table below (replace ‘Bxxx’ in part number with thermal unit number).
Above list price includes one heater element.
Heater Selection Tables
Typical Single Phase Motor
Full Load Current (amps)
Single Phase
Motor Full
Load Amps
0.82-0.94
0.95-1.05
1.06-1.22
1.23-1.34
1.35-1.51
1.52-1.71
1.72-1.93
1.94-2.14
2.15-2.40
2.41-2.72
2.73-3.15
3.16-3.55
3.56-4.00
4.01-4.40
4.41-4.88
4.89-5.19
STARTER SIZE 00,0,1 (TABLE 13)
One Thermal Unit
Standard Trip
Single Phase
Thermal Unit
Motor Full
Number
Load Amps
B1.30
5.20-5.73
B1.45
5.74-6.39
B1.67
6.40-7.13
B1.88
7.14-7.90
B2.10
7.91-8.55
B2.40
8.56-9.53
B2.65
9.54-10.6
B3.00
10.7-11.8
B3.30
11.9-13.2
B3.70
13.3-14.9
B4.15
15.0-16.6
B4.85
16.7-18.9
B5.50
19.0-21.2
B6.25
21.3-23.0
B6.90
23.1-25.5
B7.70
25.6-26.0
Standard Trip
Thermal Unit
Number
B8.20
B9.10
B10.2
B11.5
B12.8
B14.0
B15.5
B17.5
B19.5
B22.0
B25.0
B28.0
B32.0
B36.0
B40.0
B45.0
14.0-15.7
15.8-18.4
18.5-21.6
21.7-24.0
STARTER SIZE 1P (TABLE 41)
One Thermal Unit
B22.0
24.1-28.6
B25.0
28.7-30.7
B28.0
30.8-33.5
B32.0
33.6-36.0
B36.0
B40.0
B45.0
B50.0
HP
115V
230V
1/20
1.30
0.65
1/12
1.90
0.95
1/8
2.60
1.30
1/6
3.24
1.62
1/4
4.40
2.20
1/3
5.47
2.74
1/2
7.45
3.73
3/4
10.10
5.07
1
12.60
6.31
1.5
17.20
8.59
2
21.40
10.70
3
29.10
14.50
5
-- -- -21.40
Note: Single-phase motors vary widely in
amps; base heater selection on
actual motor amps whenever
possible.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
G-4
JUL-14
NEMA Combination Magnetic Starters
Feature Selection
Schneider Electric Type "S" NEMA Combination Magnetic Starters
Fusible Combination Type with fuse clips
These combination starters combine the requirements of motor overload and short circuit
protection into one package. These starters are manufactured in accordance with NEMA
standards and are UL listed. Standard short circuit rating is 100kAIC.
We supply combination starters with an adjustable Schneider Electric Motor LogicTM solid
state overload relay as standard, although conventional overload blocks with heaters are
available as an option. Solid state overloads provide superior motor protection for the
same price. See Page F21 on NEMA type "S" motor starters for details on contactors and
Motor LogicTM overloads.
These combination starters include a main 600V disconnect switch with fuse clips for
Class J fuses. Main power fuses are not included unless noted below.
NEMA 1 indoor
NEMA 3R/12
Class J fuse clips (standard)
Included
120V
24V
Customer:
HOA
Start/Stop
Off/On
Other _____
Class J power fuses included
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Hand-Off-Auto selector switch (standard)
Start-Stop pushbuttons
Off-On selector switch
Aux. Contact module (left side)
1 N.O., 1 N.C., field convertible
Aux. Contact module (right side)
1 N.O., 1 N.C., field convertible
Overload Trip Alarm Contact
On solid state overload, closes on trip (field convertible to N.C.)
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with normal and tripped LEDs
Project:
On (red)
Off (grn)
Other
Pilot Lights
24-120V Protected LED type 100,000 hours life
Option for push-to-test lamps if required
Push-to-test
Spare Fuses
Qty 3 Class J spare line fuses supplied loose
All accessories mounted and wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
H-1
JUL-14
NEMA Combination Magnetic Starters
Pricing, 460V
460V Schneider Electric Type "S" NEMA Combination Magnetic Starters with Fusible Disconnect
460V HP
3 Phase
Catalog Number
1/2 - 2
3-5
7.5 - 10
S0 -  - 4.5A-F61- 
S0 -  - 9A-F61- 
S1 -  - 18A-F61- 
15 - 25
S2 -  - 45A-F62- 
30 - 50
60 - 100
NEMA
Size
0
1
Amp
Range
Fuse Clip
Rating
1.5 - 4.5 *
3-9*
6 - 18 *
30 amp
Class J
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
$ 854
$ 1,061
$ 1,061
$ 914
$ 1,120
$ 1,120
Control Transformer
Price
Rating
Adder
$ 231
75 VA
60 amp
$ 1,409
$ 1,710
$ 1,710
$ 306
100VA
Class J
100 amp
S3 -  - 90A-F63- 
3
30 - 90
$ 2,345
$ 2,737
$ 2,737
$ 441
250VA
Class J
200 amp
S4 -  - 135A-F64- 
4
45 – 135
$ 4,436
$ 5,486
$ 5,486
$ 508
350VA
Class J
 Specify coil voltage: 24, 120, or 460; or Control Transformer: XC=460/120V, or XF=460/24V (use applicable price adder)
 Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
*
Overloads noted with * have CTs so lower amp motors may be accommodated by looping wires.
2
15 - 45
See Page F-2 for an example.
Accessories
Cat. No. Suffix
Price
Heavy-Duty Oil tight HOA
7H
$ 88
Start-Stop Pushbuttons
3
$ 88
Off-On Switch
6
Overload Trip Alarm Contact
AC04
on solid state overload (field convertible)
Aux. Contact module (left side)
SX8
1 N.O., 1 N.C., field convertible
Aux. Contact module (right side)
SX8
1 N.O., 1 N.C., field convertible
Phase Monitor
Time-Mark 257 series
PM
Phase loss/under voltage/reversal with
normal and tripped LEDs
Pilot Light
1
24-120V protected LED type 100,000 hours life
On & Off Pilot Lights
2
24-120V protected LED type 100,000 hours life
Pilot Light, push-to-test
4
24-120V protected LED type 100,000 hours life
Class J Power Fuses, Qty. 3, 600V/250V
1/2-10HP @ 460V, 1/2-7.5HP @ 208/230V
15-25HP@460V, 10hp@208V, 10-15hp@230V
Fused
30-50HP@460V, 15-25HP@208V, 20-30HP@230V
60-100HP@460V, 30-40HP@208V, 40-50HP@230V
All accessories mounted and wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
$ 88
$ 42
$ 79
$ 79
$ 360
$ 119
$ 235
$ 207
$ 60
$ 120
$ 230
$ 460
H-2
JUL-14
NEMA Combination Magnetic Starters
Pricing, 208/230V
208V Schneider Electric Type "S" NEMA Combination Magnetic Starters with Fusible Disconnect
208V HP
3 Phase
1/2 - 3/4
1 - 1.5
2-3
5
7.5
10
15 - 25
30 - 40
Catalog Number
S0 -  - 4.5A-F61- 
S0 -  - 9A-F61- 
S0 -  - 18A-F61- 
S1 -  - 27A-F61- 
S1 -  - 27A-F62- 
S2 -  - 45A-F62- 
NEMA
Size
Amp
Range
0
0
0
1
1
2
1.5 - 4.5 *
3-9*
6 - 18 *
9 - 27 *
9 - 27 *
15 - 45
Fuse Clip
Rating
30 amp
Class J
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
$ 854
$ 1,061
$ 1,061
$ 914
$ 959
$ 1,409
$ 1,120
$ 1,166
$ 1,710
$ 1,120
$ 1,166
$ 1,710
Control Transformer
Price
Rating
Adder
$ 231
75 VA
60 amp
Class J
$ 306
100VA
100 amp
S3 -  - 90A-F63- 
3
30 - 90
$ 2,345
$ 2,737
$ 2,737
$ 441
250VA
Class J
200 amp
S4 -  - 135A-F64- 
4
45 – 135
$ 4,436
$ 5,486
$ 5,486
$ 508
350VA
Class J
 Specify coil voltage: 24, 120, or 208, or Control Transformer: XA = 208/120 V or XH = 208/24 V. Use applicable price adder for
control transformer.

*
Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
Overloads noted with * have CTs so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example.
230V Schneider Electric Type "S" NEMA Combination Magnetic Starters with Fusible Disconnect
Control Transformer
Price
Rating
Adder
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
$ 854
$ 1,061
$ 1,061
$ 914
$ 959
$ 1,409
$ 1,120
$ 1,166
$ 1,710
$ 1,120
$ 1,166
$ 1,710
$ 306
100VA
$ 2,345
$ 2,737
$ 2,737
$ 441
250VA
230V HP
3 Phase
Catalog Number
1/2 - 1
1.5
3
5
7.5
10 - 15
S0 -  - 4.5A-F61- 
S0 -  - 9A-F61- 
S0 -  - 18A-F61- 
S1 -  - 27A-F61- 
S1 -  - 27A-F62- 
S2 -  - 45A-F62- 
20 - 25
S3 -  - 90A-F63- 
30
40 - 50
S3 -  - 90A-F64- 
30 - 90
$ 3,071
$ 3,071
$ 441
250VA
$ 2,669
S4 -  - 135A-F64- 
4
45 – 135
$ 4,436
$ 5,486
$ 5,486
$ 508
350VA
 Specify coil voltage: 24, 120, or 230, or Control Transformer: XB = 230/120V or XE = 230/24V. Use applicable price adder for
control transformer.

*
NEMA
Size
0
1
2
3
Amp
Range
1.5 - 4.5 *
3-9*
6 - 18 *
9 - 27 *
9 - 27 *
15 - 45
30 - 90
Fuse Clip
Rating
30 amp
Class J
60 amp
Class J
100 amp
Class J
200 amp
Class J
$ 231
75 VA
Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
Overloads noted with * have CTs, so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
H-3
JUL-14
NEMA Circuit Breaker Combination Magnetic Starters
Feature Selection
Schneider Electric Type "S" NEMA Combination Magnetic Starters
Circuit Breaker Combination Type
These combination starters combine the requirements of motor overload and short
circuit protection into one package. These starters are manufactured in accordance
with NEMA standards and are UL listed.
We supply combination starters with an adjustable Schneider Electric Motor LogicTM
solid state overload relay as standard; although conventional overload blocks with
heaters are available as an option. Solid state overloads provide superior motor
protection for the same price. See Page F-1 on NEMA type "S" motor starters for
details on contactors and Motor LogicTM overloads.
These combination starters include an input three-phase magnetic-trip only MCP style
(motor circuit protector) circuit breaker as standard. A thermal-magnetic circuit breaker
can be provided in lieu of the motor circuit protector if required.
NEMA 1 indoor
NEMA 3R/12
Other _____
Motor Circuit Protector (MCP) Circuit Breaker (standard)
Thermal-Magnetic Circuit Breaker (optional – no charge)
Included
120V
24V
Customer:
HOA
Start/Stop
Off/On
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Hand-Off-Auto selector switch (standard)
Start-Stop pushbuttons
Off-On selector switch
Aux. Contact module (left side)
1 N.O, 1 N.C., field convertible
Aux. Contact module (right side)
1 N.O., 1 N.C. field convertible
Overload Trip Alarm Contact
On solid state overload, closes on trip (field convertible to N.C.)
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with normal and tripped LEDs
Project:
On (red)
Off (grn)
Other
Pilot Lights
24-120V Protected LED type 100,000 hours life
Option for push-to-test lamps if required
Push-to-test
Spare Fuses
Qty 3 Class J spare line fuses supplied loose
All accessories mounted & wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
I-1
JUL-14
NEMA Circuit Breaker Combination Magnetic Starters
Pricing, 460V
460V Schneider Electric Type "S" NEMA Combination Magnetic Starters with Circuit Breaker
460V HP
3 Phase
½-2
3-5
7.5 - 10
15
20 - 25
30 - 50
60 - 100
Catalog Number
NEMA
Size
Amp
Range
Breaker
Rating
S0 -  - 4.5A-B30- 
1.5 - 4.5 *
30 amp
0
S0 -  - 9A-B30- 
3-9*
30 amp
S1 -  - 18A-B30- 
1
6 – 18 *
30 amp
S2 -  - 45A-B30- 
30 amp
2
15 – 45
S2 -  - 45A-B50- 
50 amp
S3 -  - 90A-B100- 
3
30 - 90
100 amp
S4 -  - 135A-B250- 
4
45 – 135
250 amp
 Specify coil voltage: 24, 120, or 460, or Control Transformer:
control transformer.

*
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
$ 1,153
$ 1,360
$ 1,360
$ 1,197
$ 1,404
$ 1,404
$ 1,691
$ 1,992
$ 1,992
Control Transformer
Price
Rating
Adder
$ 231
75 VA
$ 306
100VA
$ 2,368
$ 2,620
$ 2,620
$ 441
250VA
$ 5,191
$ 6,283
$ 6,283
$ 508
350VA
XC = 460/120V or XF = 460/24V. Use applicable price adder for
Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
Overloads noted with * have CTs, so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example.
Accessories
Cat. No. Suffix
Price
Heavy-Duty Oil tight HOA
7H
$ 88
Start-Stop Pushbuttons
3
$ 88
Off-On Switch
6
Overload Trip Alarm Contact
AC04
on solid state overload (field convertible)
Aux. Contact module (left side)
SX8
1 N.O., 1 N.C., field convertible
Aux. Contact module (right side)
SX8
1 N.O., 1 N.C., field convertible
Phase Monitor
Time-Mark 257 series
PM
Phase loss/under voltage/reversal with normal
and tripped LEDs
Pilot Light
1
24-120V protected LED type 100,000 hours life
On & Off Pilot Lights
2
24-120V protected LED type 100,000 hours life
Pilot Light, push-to-test
4
24-120V protected LED type 100,000 hours life
All accessories mounted and wired at no charge.
Pilot light voltage must match coil voltage.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
$ 88
$ 42
$ 79
$ 79
$ 360
$ 119
$ 235
$ 207
I-2
JUL-14
NEMA Circuit Breaker Combination Magnetic Starters
Pricing, 208/230V
208V Schneider Electric Type "S" NEMA Combination Magnetic Starters with Circuit Breaker
208V HP
3 Phase
½-¾
1 – 1.5
2-3
5
7.5
10
15 - 25
30 - 40
Catalog Number
NEMA
Size
Amp
Range
Breaker
Rating
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
Control Transformer
Price
Rating
Adder
S0 -  - 4.5A-B30- 
1.5 - 4.5 *
30 amp
0
S0 -  - 9A-B30- 
3-9*
$ 1,153
$ 1,360
$ 1,360
S0 -  - 18A-B30- 
6 - 18 *
30 amp
$ 231
75 VA
S1 -  - 27A-B30- 
30 amp
1
9 - 27 *
$ 1,197
$ 1,404
$ 1,404
S1 -  - 27A-B50- 
50 amp
S2 -  - 45A-B50- 
2
15 - 45
50 amp
$ 1,691
$ 1,992
$ 1,992
$ 306
100VA
S3 -  - 90A-B100- 
3
30 - 90
100 amp
$ 2,368
$ 2,620
$ 2,620
$ 441
250VA
S4 -  - 135A-B250- 
4
45 – 135
250 amp
$ 5,191
$ 6,283
$ 6,283
$ 508
350VA
 Specify coil voltage: 24, 120, or 208, or Control Transformer: XA = 208/120V or XH = 208/24V. Use applicable price adder for
control transformer.

*
Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
Overloads noted with * have CTs, so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example.
230V Schneider Electric Type "S" NEMA Combination Magnetic Starters with Circuit Breaker
230V HP
3 Phase
½-1
1.5
2–3
5 – 7.5
10
15
20 - 30
40 - 50
Catalog Number
NEMA
Size
Amp
Range
Breaker
Rating
NEMA 1
Indoor
-G
NEMA 3R
Rain tight
-R
NEMA 12
Dust tight
-D
Control Transformer
Price
Rating
Adder
S0 -  - 4.5A-B30- 
1.5 - 4.5 *
30 amp
S0 -  - 9A-B30- 
0
3–9*
$ 1,153
$ 1,360
$ 1,360
30 amp
$ 231
75 VA
S0 -  - 18A-B30- 
6 - 18 *
S1 -  - 27A-B30- 
1
9 - 27 *
30 amp
$ 1,197
$ 1,404
$ 1,404
S2 -  - 45A-B50- 
50 amp
$ 1,197
$ 1,992
$ 1,992
$ 306
100VA
2
15 – 45
S2 -  - 45A-B75- 
75 amp
S3 -  - 90A-B100- 
3
30 - 90
100 amp
$ 2,368
$ 2,620
$ 2,620
$ 441
250VA
S4 -  - 135A-B250- 
4
45 – 135
250 amp
$ 5,191
$ 6,283
$ 6,283
$ 508
350VA
 Specify coil voltage: 24, 120, or 230, or Control Transformer: XB = 230/120V or XE = 230/24V. Use applicable price adder for
control transformer.

*
Specify Enclosure: - G, -R, -D as listed above, then add catalog number suffix for accessories, i.e. 7H for HOA.
Overloads noted with * have CTs, so lower amp motors may be accommodated by looping wires.
See Page F-2 for an example.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
I-3
JUL-14
NEMA Multispeed Magnetic Starters
Feature Selection
Schneider Electric Type "S" NEMA Multispeed
Starters
These full-voltage magnetic starters are manufactured in
accordance with NEMA standards and are UL listed. Schneider
Electric Type "S" NEMA starters are the standard of the industry.
We supply NEMA Rated starters with an adjustable Schneider
Electric Motor LogicTM solid state overload relay as standard;
although conventional overload blocks with heaters are available as
an option.
Solid state overloads provide superior motor protection for the same
price as conventional heaters. See Page F-1 on NEMA type "S"
motor starters for details on contactors and Motor LogicTM
overloads.
NEMA starters have (1) N.O. auxiliary contact standard.
NEMA 1 indoor
Included
120V
24V
Customer:
AOLH
HOA & HOL
Project:
NEMA 3R/12
Other _____
Accessories
Control power transformer
with primary and secondary fuses installed
120V secondary (standard)
24V secondary (optional)
Cover Control
Auto-Off-Low-High selector switch (standard)
Hand-Off-Auto and High-Off-Low switches
Automatic decelerating timer (standard)
Multispeed motors should never be rapidly switched from high to
low speed, or damage to the motor or driven equipment may
result. Addition of a timer delays energizing of the motor in low
speed after high speed operation.
Automatic accelerating timer
This option adds two relays and two timers to ensure that the
motor always starts at low speed. When high speed is selected,
the relays start the motor on low, then automatically switch to high
speed after an adjustable time. These are commonly used with
high inertia fans because starting stress on the motor is
substantially reduced resulting in longer motor life. The decelerating
timer option is usually used in conjunction to allow completely
automatic control.
Phase Monitor - Time-Mark 257 series
Phase loss/under voltage/reversal with normal and tripped LEDs
High (red)
Low (yel)
Off (grn)
Other
Pilot Lights
24-120V Protected LED type 100,000 hours life
Option for push-to-test lamps if required
Push-to-test
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
J-1
JUL-14
NEMA Multispeed Magnetic Starters
Pricing, 2-Winding and 1-Winding
Schneider Electric Type "S" NEMA Multispeed Starters - 2 SEPARATE WINDINGS
Maximum HP Ratings
208V
230V
460V
1.5
3
7.5
10
25
40
75
150
1.5
3
7.5
15
30
50
100
200
2
5
10
25
50
100
200
400
2-Speed
2-Winding
Catalog Number
S00-M2W-  - # - 
S0-M2W-  - # - 
S1-M2W-  - # - 
S2-M2W-  - # - 
S3-M2W-  - # - 
S4-M2W-  - # - 
S5-M2W-  - # - 
S6-M2W-  - # - 
NEMA 1
Indoor
-G
$ 1,124
$ 1,222
$ 1,377
$ 2,462
$ 3,859
$ 9,464
$ 22,335
$ 45,698
NEMA 3R
Raintight
-R
$ 1,468
$ 1,566
$ 1,720
$ 2,951
$ 4,967
$ 11,657
$ 31,453
$ 50,706
NEMA 4
Watertight
-W
$ 2,188
$ 2,286
$ 2,419
$ 3,770
$ 5,765
$ 13,363
$ 31,453
$ 51,403
NEMA 12
Dusttight
-D
$ 1,468
$ 1,566
$ 1,720
$ 2,951
$ 4,967
$ 11,657
$ 31,453
$ 50,706
Control Transformer
Price
Rating
Adder
$ 231
75 VA
$ 306
$ 441
$ 508
100 VA
250VA
350VA
$ 586
500VA
 Specify coil voltage: 24, 120, or 460; or Control Transformer: XC = 460/120V, XF = 460/24V, XB = 230/120V,
XE = 230/24V, XA = 208/120V, XH = 208/24V. Use applicable price adder for control transformer.
#

Specify overload relays, high speed and low speed. See part numbering sheet for amp ranges and codes.
Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories.
See Page F-2 for an example.
Schneider Electric Type "S" NEMA Multispeed Starters - 1 RECONNECTABLE WINDING
Maximum HP Ratings
208V
230V
460V
1.5
3
7.5
10
25
40
75
150
1.5
3
7.5
15
30
50
100
200
2
5
10
25
50
100
200
400
2-Speed
1-Winding
Catalog Number
S00-M1W-  - # - 
S0-M1W-  - # - 
S1-M1W-  - # - 
S2-M1W-  - # - 
S3-M1W-  - # - 
S4-M1W-  - # - 
S5-M1W-  - # - 
S6-M1W-  - # - 
NEMA 1
Indoor
-G
$ 1,612
$ 1,710
$ 1,843
$ 3,350
$ 5,056
$ 13,496
$ 26,667
$ 60,111
NEMA 3R
Raintight
-R
$ 1,955
$ 2,053
$ 2,186
$ 3,836
$ 6,164
$ 15,689
$ 35,784
$ 65,140
NEMA 4
Watertight
-W
$ 2,676
$ 2,774
$ 2,884
$ 4,634
$ 6,872
$ 17,395
$ 35,784
$ 72,573
NEMA 12
Dusttight
-D
$ 1,955
$ 2,053
$ 2,186
$ 3,836
$ 6,164
$ 15,689
$ 35,784
$ 65,140
Control Transformer
Price
Rating
Adder
$ 231
75 VA
$ 306
$ 441
$ 508
100 VA
250VA
350VA
$ 586
500VA
 Specify coil voltage: 24, 120, or 460; or Control Transformer: XC = 460/120V, XF = 460/24V, XB = 230/120V,
XE = 230/24V, XA = 208/120V, XH = 208/24V. Use applicable price adder for control transformer.
#

Specify overload relays, high speed and low speed. See Page B-2 for amp ranges and codes.
Specify Enclosure: - G, -R, -W, -D as listed above, then add catalog number suffix for accessories.
See Page F-2 for an example.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
J-2
JUL-14
NEMA Multispeed Magnetic Starters
Pricing, Accessories
Accessories
Cat. No. Suffix
Price
HOA and High-Off-Low switches
7
$ 176
Automatic decelerating timer
Auto-Off-Low-High selector switch and
decelerating timer
Overload Trip Alarm Contact
on solid state overload (field convertible)
Aux. Contact module (left side)
1 N.O., 1 N.C., field convertible
Aux. Contact module (right side)
1 N.O., 1 N.C., field convertible
9
$ 219
8
$ 307
AC04
$ 42
SX8
$ 79
SX8
$ 79
5
$ 656
Automatic accelerating timer
Phase Monitor
Time-Mark 257 series
PM
Phase loss/under voltage/reversal
Normal and tripped LEDs
Pilot Lights (2), for high and low speed
indication
2
24-120V protected LED type 100,000 hours life
Pilot Lights (3), for high speed, low speed
and off indication
3
24-120V protected LED type 100,000 hours life
Pilot Light, push-to-test
4
24-120V protected LED type 100,000 hours life
All accessories mounted & wired at no charge.
Pilot light voltage must match coil voltage.
$ 360
$ 235
$ 350
$ 207
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
J-3
JUL-14
NEMA Manual Starters Pricing and Features
Fractional HP Manual Starters
Catalog Prefix
Description
Toggle Switch 1 Pole
Toggle Switch 1 Pole w/Red Pilot Light
Toggle Switch 2 Pole
Toggle Switch 2 Pole w/Red Pilot Light
MS1MS1PMS2MS2P-
NEMA 1
Surface
Mount
-G
NEMA 1
Flush
Plate
-SS
NEMA 4
Outdoor
-W
-E
-N
$ 83
$ 117
$ 94
$ 126
$ 83
$ 117
$ 94
$ 126
$ 265
$ 354
$ 277
$ 365
$ 288
$ 72
$ 105
$ 83
$ 116






Motor Full Load
Current (Amps)
0.41-0.44
0.45-0.49
0.50-0.53
0.54-0.58
0.59-0.65
0.66-0.71
0.72-0.78
0.79-0.85
0.86-0.96
0.97-1.04
1.05-1.16
1.17-1.29
1.30-1.37
1.38-1.47
1.48-1.56
1.57-1.65
1.66-1.79
1.80-1.95
1.96-2.15
2.16-2.38
2.39-2.75
2.76-2.84
2.85-3.06
Heater
Part
Number
A.49
A.54
A.59
A.65
A.71
A.78
A.86
A.95
A1.02
A1.16
A1.25
A1.39
A1.54
A1.63
A1.75
A1.86
A1.99
A2.15
A2.31
A2.57
A2.81
A3.61
A3.95
Motor Full Load
Current (Amps)
3.07-3.45
3.46-3.70
3.71-4.07
4.08-4.32
4.33-4.90
4.91-5.35
5.36-5.85
5.86-6.41
6.42-6.79
6.80-7.57
7.58-8.15
8.16-8.98
8.99-9.67
9.68-9.95
9.96-10.8
10.9-12.1
12.2-13.1
13.2-13.9
14.0-15.0
15.1-16.0
Heater
Part
Number
A4.32
A4.79
A5.30
A5.78
A6.20
A6.99
A7.65
A8.38
A9.25
A9.85
A11.0
A11.9
A13.2
A14.1
A14.8
A16.2
A17.9
A19.8
A21.3
A25.2




NEMA 7/9
Expl. Proof
Open Type
(No encl.)
$ 298
These switches provide manual on-off control and overload
protection for fractional HP motors.
Heater is required for switch to function. Select heater from
table below. When ordering, specify complete part number
such as MS1P-G for a one-pole switch with red pilot light in
surface mount NEMA 1 enclosure. Only one heater is required
for either one or two pole switches. Price includes heater.
Use ACTUAL motor amps from nameplate to select heater.
1 pole units rated 1HP max. @ 115-230-277V, 16 amps.
2 pole units rated 1HP max. @ 115-230-277V, 16 amps.
1 pole units are normally used for 120V applications.
2 pole units are normally used for 208-230V applications or
where specified by the consulting engineer.
For key switch, substitute "MK" for "MS" in part number, and
add $23 list.
All units are UL listed.
Explosion proof units are also rated NEMA 3R for outdoor use.
For non-hazardous locations outdoors, use NEMA 4.
Many other configurations including multi-speed single-phase
manual motor control are available; contact Palmer DCS.
Optional
Accessory Item
Handle guard
with padlock
provisions
Pilot light kit for
field installation,
Red, 115-240V
Pilot light kit for
field installation,
Green, 115-240V
Spare Key for
key-type switches
Heaters
Part Number
List Price
2510FL1
$ 11
9999PL10
$ 34
9999PL10G
$ 34
2510FK1
$4
(select from
table)
Included
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
K-1
JUL-14
NEMA Manual Starters Dimensions
NEMA 1 flush mount
NEMA 1 surface mount
NEMA 4 indoor/outdoor
NEMA 7/9 explosion-proof
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
K-2
JUL-14
NEMA Manual Starters Pricing and Features
Fractional HP Manual Starters
NEMA 1
Flush
Plate
NEMA 4
Outdoor
NEMA 7/9
Expl. Proof
Open Type
(No encl.)
Description
NEMA 1
Surface
Mount
Toggle Switch 1 Pole
Toggle Switch 1 Pole w/Red Pilot Light
Toggle Switch 2 Pole
Toggle Switch 2 Pole w/Red Pilot Light
MS1-G
MS1P-G
MS2-G
MS2P-G
MS1-SS
MS1P-SS
MS2-SS
MS2P-SS
MS1-W
MS1P-W
MS2-W
MS2P-W
MS1-E
MS1-N
MS1P-N
MS2-N
MS2P-N





Motor Full Load
Current (Amps)
0.41-0.44
0.45-0.49
0.50-0.53
0.54-0.58
0.59-0.65
0.66-0.71
0.72-0.78
0.79-0.85
0.86-0.96
0.97-1.04
1.05-1.16
1.17-1.29
1.30-1.37
1.38-1.47
1.48-1.56
1.57-1.65
1.66-1.79
1.80-1.95
1.96-2.15
2.16-2.38
2.39-2.75
2.76-2.84
2.85-3.06
Heater
Part
Number
A.49
A.54
A.59
A.65
A.71
A.78
A.86
A.95
A1.02
A1.16
A1.25
A1.39
A1.54
A1.63
A1.75
A1.86
A1.99
A2.15
A2.31
A2.57
A2.81
A3.61
A3.95
Motor Full Load
Current (Amps)
3.07-3.45
3.46-3.70
3.71-4.07
4.08-4.32
4.33-4.90
4.91-5.35
5.36-5.85
5.86-6.41
6.42-6.79
6.80-7.57
7.58-8.15
8.16-8.98
8.99-9.67
9.68-9.95
9.96-10.8
10.9-12.1
12.2-13.1
13.2-13.9
14.0-15.0
15.1-16.0
Heater
Part
Number
A4.32
A4.79
A5.30
A5.78
A6.20
A6.99
A7.65
A8.38
A9.25
A9.85
A11.0
A11.9
A13.2
A14.1
A14.8
A16.2
A17.9
A19.8
A21.3
A25.2





MS2-E
These switches provide manual on-off control and overload
protection for fractional HP motors.
Heater is required for switch to function. Select heater from
table below. When ordering, specify complete part number
such as MS1P-G for a one-pole switch with red pilot light in
surface mount NEMA 1 enclosure. Only one heater is required
for either one or two pole switches. Price includes heater.
Use ACTUAL motor amps from nameplate to select heater.
1 pole units rated 1HP max. @ 115-230-277V, 16 amps.
2 pole units rated 1HP max. @ 115-230-277V, 16 amps.
1 pole units are normally used for 120V applications.
2 pole units are normally used for 208-230V applications or
where specified by the consulting engineer.
For key switch, substitute "MK" for "MS" in part number
All units are UL listed.
Explosion proof units are also rated NEMA 3R for outdoor use.
For non-hazardous locations outdoors, use NEMA 4.
Many other configurations including multi-speed single-phase
manual motor control are available; contact Palmer DCS.
Optional
Accessory Item
Handle guard
with padlock
provisions
Pilot light kit for
field installation,
Red, 115-240V
Pilot light kit for
field installation,
Green, 115-240V
Spare Key for
key-type switches
Heaters
Part Number
2510FL1
9999PL10
9999PL10G
2510FK1
(select from
table)
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
K-1
JUL-14
NEMA Manual Starters Dimensions
NEMA 1 flush mount
NEMA 1 surface mount
NEMA 4 indoor/outdoor
NEMA 7/9 explosion-proof
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
K-2
JUL-14
General and Heavy Duty Safety Switches
Feature Selection
Schneider Electric General & Heavy Duty Safety Switches
NEMA1 Indoor and NEMA3R Outdoor
General duty safety switches are designed for residential and commercial applications
where economy is a prime consideration. Typical loads are lighting, air conditioning
and appliances. Heavy duty safety switches are designed for applications where
performance and continuity of service are required.
All safety switches feature quick-make, quick-break operating mechanisms, a dual cover
interlock and a color coded indicator handle.
All safety switches are suitable for use as service equipment when equipped with a neutral
assembly or equipment ground kit. They are UL Listed, and meet or exceed the NEMA
Standard KS1-1990.
Fusible safety switches will accept Class J or R fuses as standard. With Class J or R
fuses installed, the switch is UL Listed for use on systems with up to 200,000 RMS
symmetrical amperes available fault current.
Choose one
Enclosure Type
NEMA 1 Indoor
NEMA 3R Rainproof
Choose one
Voltage Rating
460-600VAC Rated (3-phase applications only)
208-230VAC Rated (for 120/208/230V, 1-phase and 3-phase)
Choose one
Switch Type
Fusible
Non-Fusible
Choose one
Neutral or Ground (required for Service Entrance rating)
Neutral Assembly Kit
Equipment Ground Kit
Choose
Other Accessories
Auxiliary Contact Kit (1 N.O./1 N.C. contact, for control
circuit)
Fuses, Class J (Qty. 3)
Rain-proof Bolt-On Hubs (for NEMA 3R enclosures)
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
M-1
JUL-14
General and Heavy Duty Safety Switches
Pricing
Heavy Duty Switches (Single-Throw, 3-Pole):
460-600 Volt – Fusible
Amps
3-Phase
NEMA 1 Indoor
Catalog Number
NEMA 1
List Price
NEMA 3R Outdoor
Catalog Number
NEMA 3R
List Price
Max. HP Rating
@ 460V
30
60
100
200
400
H361
H362
H363
H364
H365
$ 340
$ 410
$ 765
$ 1,200
$ 2,930
H361RB
H362RB
H363RB
H364RB
H365R
$ 579
$ 679
$ 1,058
$ 1,454
$ 3,280
15
30
60
125
250
460-600 Volt – Non-fusible
Amps
3 Phase
NEMA 1 Indoor
Catalog Number
NEMA 1
List Price
NEMA 3R Outdoor
Catalog Number
NEMA 3R
List Price
Max. HP Rating
@ 460V
30
60
100
200
400
HU361
HU362
HU363
HU364
HU365
$ 180
$ 314
$ 504
$ 779
$ 1,806
HU361RB
HU362RB
HU363RB
HU364RB
HU365R
$ 314
$ 564
$ 790
$ 956
$ 2,473
15
30
60
125
250
General Duty Switches (Single-Throw, 3-Pole):
208-230 Volt – Fusible
Amps
3 Phase
NEMA 1 Indoor
Catalog Number
NEMA 1
List Price
NEMA 3R Outdoor
Catalog Number
NEMA 3R
List Price
Max. HP Rating
@ 230V
30
60
100
200
400
D321N
D322N
D323N
D324N
D325N
$ 121
$ 210
$ 363
$ 774
$ 2,005
D321NRB
D322NRB
D323NRB
D324NRB
D325NR
$ 189
$ 284
$ 526
$ 941
$ 2,508
7.5
15
30
50
100
208-230 Volt – Non-Fusible
Amps
3 Phase
NEMA 1 Indoor
Catalog Number
NEMA 1
List Price
NEMA 3R Outdoor
Catalog Number
NEMA 3R
List Price
Max. HP Rating
@ 230V
30
60
100
200
400
DU321
DY322
DU323
DU324
DU325
$ 100
$ 133
$ 307
$ 569
$ 1,416
DU321RB
DU322RB
DU323RB
DU324RB
n/a
$ 189
$ 285
$ 526
$ 941
7.5
15
30
50
100
Note: General Duty Safety Switches are typically used for residential applications, and may not meet the requirements of your
specification. Verify that General Duty is acceptable, or use Heavy Duty instead.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
M-2
JUL-14
General and Heavy Duty Safety Switches
Accessories
Accessories
Equipment Ground Kit
30A Switch Rating
60A Switch Rating
100A Switch Rating
200A – 400A Switch Rating
600A Switch Rating
Neutral Assembly Kit
30A, 230V Switch Rating
30A, 600V Switch Rating
60A, Fusible Switch Rating
60A, Non-Fusible Switch Rating
100A, Fusible Switch Rating
100A, Non-Fusible Switch Rating
200A Switch Rating
400A Switch Rating
Auxiliary Contact Kit
30A Switch Rating
60A-200A Switch Rating
400A Switch Rating
Rain-proof Bolt-On Hubs
3/4” Conduit
1” Conduit
1-1/4” Conduit
1-1/2” Conduit
2” Conduit
2-1/2” Conduit
Fuses, Class J (Qty. 3)
1-30A
35-60A
70-100A
110-200A
225-400A
Catalog No.
List Price
GTK03
GTK03
GTK0610
PKOGTA2
PKOGTA2 (x 2)
$8
$8
$ 12
$ 36
$ 72
SN0610
SN0610
SN0610
SN0610
SN0610
SN0610
SN20A
H600SN
$ 69
$ 69
$ 69
$ 69
$ 69
$ 69
$ 129
$ 211
EIK032
EIK2
THAUX62
$ 140
$ 201
$ 343
B075
B100
B125
B150
B200
B250
$ 22
$ 22
$ 22
$ 22
$ 40
$ 66
LPJxxSP
LPJxxSP
LPJxxSP
LPJxxSP
LPJxxSP
$ 60
$ 120
$ 230
$ 460
$ 800
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
M-3
JUL-14
Motor Amps Reference Data
Typical Motor Amps for Three-Phase Motors
For quick reference, use actual motor amps whenever possible.
HP
1/2
3/4
1
1.5
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
208/3/60V
Typical EPACT high
NEC amps
efficiency motors
1.7 - 2.1
2.3
2.5 - 2.7
3.2
3.1 - 3.4
4.2
4.5 - 4.8
6
6.0 - 6.3
7.8
8.3 - 10.3
11
14 - 15
17.5
20 - 22
25
28 - 30
32
41 - 44
48
54 - 58
62
66 - 70
78
80 - 82
92
102 - 107
120
129 - 133
150
157 - 162
177
196 - 207
221
265 - 270
285
230/3/60V
Typical EPACT high
NEC amps
efficiency motors
1.6 - 2.2
2
2.2 - 2.8
2.8
2.8 - 3.6
3.6
4.0 - 5.2
5.2
5.0 - 6.8
6.8
7.2 - 9.0
9.6
12.2 - 14.6
15.2
18.4 - 19.2
22
23.8 - 25.4
28
35.8 - 38
42
46.8 - 50
54
57.4 - 60
68
70 - 72
80
90 - 94
104
112 - 118
130
136 - 140
154
172 - 180
192
232 - 244
248
290 - 304
312
330 - 344
360
460/3/60V
Typical EPACT high
NEC amps
efficiency motors
.8 - 1.1
1
1.1 - 1.4
1.4
1.4 - 1.8
1.8
2.0 - 2.6
2.6
2.5 - 3.4
3.4
3.6 - 4.5
4.8
6.1 - 7.3
7.6
9.2 - 9.6
11
11.9 - 12. 7
14
17.7 - 19
21
23.4 - 25
27
28.7 - 30
34
35 - 36
40
45 - 47
52
56 - 59
65
68 - 70
77
86 - 90
96
116 - 122
124
145 - 152
156
165 - 172
180
220 - 233
230
Typical Motor Amps for Single-Phase Motors
For quick reference, use actual motor amps whenever possible.
HP
1/20
1/12
1/8
1/6
1/4
1/3
1/2
3/4
1
1.5
2
3
5
115/1/60V
1.30
1.90
2.60
3.24
4.40
5.47
7.45
10.10
12.60
17.20
21.40
29.10
-- -- --
230/1/60V
0.65
0.95
1.30
1.62
2.20
2.74
3.73
5.07
6.31
8.59
10.70
14.50
21.40
Note: Single-phase motors vary widely in amps, so base overload
or heater selection on actual motor amps whenever possible.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
R-1
JUL-14
Reference Data/Glossary
TYPES OF CONTROL
COMMON MOTOR CONTROL TERMS
Two Wire Control (also called Low Voltage Release)
ACROSS-THE-LINE: A method of motor starting which merely connects the motor directly to
the power source for starting and running; also called Full Voltage starting. Motor typically
draws 5 - 8 times its normal running current during starting.
AMBIENT COMPENSATION: Overload relays operate when their heaters reach a certain
temperature; thus, the actual trip point in amps can vary widely depending on the temperature
around the starter. Ambient compensated overload relays trip at the same amp value
regardless of the temperature in the starter enclosure. Heater blocks are usually not ambient
compensated, but all Schneider Electric Telemecanique and Motor Logic solid-state
overloads are ambient compensated standard.
AUXILIARY CONTACTS: A low current rated contact on a motor starter in addition to the
main power contacts, used to signal other devices whether the contactor is open or closed.
COMBINATION STARTER: An assembly consisting of a safety disconnect and starter
"combined" in a single, pre-wired enclosure. Provides additional safety since the door to the
starter enclosure cannot be opened unless the power is turned off (although a "defeater"
mechanism is usually provided for trained personnel). Fusible disconnect and circuit breaker
types are available, which provide motor on-off control, motor overload protection, and short
circuit protection in one package. Non-fusible types are available for use where only the
safety disconnect (no short circuit protection) is needed.
CLASS: Term used to describe how long it takes an overload relay to trip during motor
starting, typically, Class 10 (10 seconds) or Class 20 (20 seconds). We recommend use of
Class 10 overloads for most loads, unless high load inertia requires a longer trip time.
CONTACTOR: A device to repeatedly close or open an electric power circuit. Allows
manual or auto control of lights, heaters, motors, etc. A contactor does not provide short
circuit protection or motor running overload protection.
CONTROL POWER TRANSFORMER: A small transformer in the starter enclosure used to
provide a low voltage (usually 120V or 24V) to the starter coil. Costs a little more for
equipment but usually results in significant installed savings.
FULL VOLTAGE STARTER: (See Across-the-Line)
HEATERS: These are small coils of wire designed to mount in an overload relay. Heaters
are made in many, many ratings and are selected from a series of tables based on motor
amps, type of starter, ambient temperature, size of starter enclosure, motor acceleration time
and other factors. Heaters have significant installed cost disadvantages and do not provide
nearly the protection of dial-type bimetal overloads or dial-type solid state overloads. Heaters
typically provide NO single-phasing protection at all. Dial type overloads are provided on all
Schneider Electric Telemecanique starters or Schneider Electric type "S" NEMA starters
unless specified otherwise.
OVERLOAD RELAY: Most induction motors have no internal protection and so must be
protected from overload by an external device. Overload relays measure the current flowing
to the motor and stop the motor if the current exceeds the motor rating. See also Heaters &
Single-Phasing.
PRIMARY FUSES: Refers to a pair of high voltage fuses provided to protect the line side of
a control power transformer required by the NEC. Primary and secondary fuses are provided
standard on all our starters with control power transformers.
REDUCED VOLTAGE STARTER: Electric motors typically have an inrush of 600-800%
amps when started across-the-line. This can cause voltage dips on the electrical system, or
can cause equipment problems due to high starting torque. These problems can be mitigated
by use of a "reduced voltage starter". These are more complex and expensive than full
voltage starters, but starting amps can be reduced by half to two-thirds. Usually used for
larger motors to avoid voltage dips when a motor starts, or to cushion the effect of hard
starting. The most common types are autotransformer, wye-delta (or star-delta), part
winding, and solid state types. Solid state types can prevent "water-hammer" on pump
installations.
SINGLE PHASING: This term refers to a common fault condition on a three phase power
system where one of the wires is open-circuited. Motors will usually continue to run under
this condition but heat up rapidly and may be damaged unless special protection is provided.
Schneider Electric Telemecanique overloads lower the trip setting by approx. 25% under
single phase conditions, and Schneider Electric Motor Logic™ solid state overloads trip
motors in 3 seconds under single phase conditions.
STARTER: This term refers to a contactor and overload relay assembled together. The
starter assembly provides motor control and running protection but not short circuit protection.
This term means the starter is controlled by a maintained contact switch such
as a thermostat, time clock, pressure switch, or maintained contact from a
building automation system. The starter will drop out when there is a power
failure and will start again immediately when power returns. A Hand-Off-Auto
switch is commonly used with this type of control.
Three Wire Control (also called Low Voltage Protection)
This term means the starter is controlled by momentary contact switches,
with a "holding" or "seal-in" auxiliary contact on the starter. The starter will
drop out when there is a power failure, but will NOT restart when power
returns until the momentary start button is pressed once again.
This type of control should be used whenever automatic restart would pose a
safety hazard, such as on a table saw or other machine tools. A start-stop
pushbutton station is the most common way of providing three-wire control.
Three-wire control is not recommended for unattended equipment where
operator safety is not an issue, since the equipment must be manually restarted after any power bump.
All Schneider Electric magnetic starters may be wired for either type of
control.
CONTROL POWER CONNECTIONS
Magnetic starters require two voltage connections: one for the main motor's
power, and a second source for the starter coil. There are three ways to
connect the starter coil (control) voltage source:
1) LINE VOLTAGE CONTROL:
In this case, the coil voltage is the same as the motor voltage and its power is
taken directly from the incoming line.
 Advantages: Lower starter cost; main disconnect switch turns off both
main power and control voltage.
 Disadvantages: High voltage is present on pilot devices such as
thermostats. This is almost always unacceptable, so line voltage
control is seldom used.
2) SEPARATE CONTROL:
In this case, the coil is powered from a separate low voltage source, usually
120V or 24V.
 Advantages: Low starter cost, often the default choice simply because
starters with control transformers are seldom available from
wholesalers except on special order.
 Disadvantages: Main disconnect switch does not turn off control
voltage, a possible safety hazard. Usually the highest installed cost, by
far, due to the high cost of field installing wire & conduit to bring in the
control power.
3) CONTROL POWER TRANSFORMER:
This provides a step-down transformer inside the starter enclosure to create
the low voltage control source directly from the incoming line.
 Advantages: Provides low voltage on pilot devices; main disconnect
turns off both power and control voltages - best operator safety.
 Disadvantages: Somewhat higher starter cost, but LOWEST installed
cost because separate control power need not be piped in.
Note: QUICK DELIVERY is available for starters with control transformers.
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
R-2
JUL-14
2810 South Raritan Street, Englewood, Colorado 80110
Phone: 720-484-8547
Fax: 303-330-0179
www.palmerdcs.com
Download