INTELLICHEM® WATER CHEMISTRY CONTROLLER Alarm Menu Select INTELLICHEM WATER CHEMISTRY ® INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical Support Phone: (800) 831-7133 - Fax: (800) 284-4151 visit www.pentairpool.com and www.staritepool.com: CONTENTS IMPORTANT WARNING AND SAFETY INSTRUCTIONS ....................................... IntelliChem Overview ............................................................................................... Operator Controls Indicators and Alarm LEDs ......................................................... pH Settings and ORP Settings Buttons .................................................................... Auto Setup ................................................................................................................ IntelliChem Menus ................................................................................................... pH Menu ................................................................................................................... ORP Menu ................................................................................................................ Configuration Menu .................................................................................................. Saturation Index ....................................................................................................... Installation ................................................................................................................ Setting up IntelliTouch Automation Control System ................................................. Setting up EasyTouch Automation Control System ................................................. Setting up SunTouch Automation Control System ................................................... Troubleshooting ........................................................................................................ Maintenance ............................................................................................................. Replaceable Parts List ............................................................................................. P/N 521363 Rev C - 10/12 INTELLICHEM® Water Chemistry Controller Installation and User’s Guide i 1 2 3 6 9 11 14 17 24 28 43 45 46 46 51 54 i IMPORTANT WARNING AND SAFETY INSTRUCTIONS SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY. INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas. It is important to comply with these codes, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information. IMPORTANT NOTICE - Attention Installer: This Installation and User’ s Guide (“Guide”) contains important information about the installation, operation and safe use of this product. This Guide should be giv en to the o wner and/or oper ator of this product. Before installing this product, read and follow all warning notices and instructions in this Guide . Failure to follow warnings and instructions can result in severe injury, death, or proper ty damage. Call (800) 831-7133 f or additional free copies of these instructions. Please refer to www.pentairpool.com for more information related to this products. DO NOT INSTALL THE INTELLICHEM ® CHEMICAL CONTROLLER WHERE IT CAN BE ACCESSIBLE TO THE PUBLIC. RISK OF ELECTRICAL SHOCK OR ELECTROCUTION: BEFORE WORKING ON INTELLICHEM® CHEMICAL CONTROLLER: Always disconnect power to the IntelliChem controller at the circuit breaker before servicing. Failure to do so could result in death or serious injury to service person, pool users or others due to electric shock. BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING THE INTELLICHEM CONTROLLER. AC Power may be supplied to the relay terminals Ex_Relay1 and Ex_Relay2 from other sources. See page 31 for details. This product must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the National Electr ical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.2. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to proper ty. BEFORE USING YOUR POOL, SPA OR HOT TUB, CHECK THE pH AND SANITIZER LEVELS OF THE WATER. Do not permit children to operate this equipment. When mixing acid with w ater, ALWAYS ADD ACID TO WATER. NEVER ADD WATER TO ACID. When adding any chemical to the pool/spa, be sure to f ollow the manufacturer’s instructions thoroughly. DO NOT MIX SODIUM HYPOCHLORITE AND MURATIC ACID Risk of electrical shock. Connect IntelliChem controller to a ground-fault interrupter-circuit (GFCI). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI. IF “CLEAR OVERFEED LIMIT” SETTING IS SET TO 24 HOURS, DO NOT SET “FEED TIME” GREATER THAN 20 HOURS AS THIS WILL VOID NSF CERTIFICATION. NTELLICHEM® Water Chemistry Controller Installation and User’s Guide ii IMPORTANT WARNING AND SAFETY INSTRUCTIONS WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling into any pipes. Securely fasten all electrical, water and chemical lines. Locate chemical feed pumps and chemical storage tanks in a safe and secure area. Strictly follow the acid manufacturers safety and handling protocols including hand, body and eye protection when transferring or handling acid. Safety precautions should be used when handling Muriatic acid to control pH water levels. Muriatic acid can cause serious body injury and damage pool equipment. Extra care must be taken when installing, maintaining and operating acid pump feed systems. Acid is dangerous to handle and should be properly contained, transported, poured, stored, and dispensed. • • • Check the pH and sanitizer levels of the water before use. Periodically use an independent pH and Chlor ine test kit to v erify that pH and chlorine is at a safe level. If the pH and Oxidation Reduction P otential (ORP) or Flow Cell sensors are broken, depleted or dirty with oils, lotions, or other contaminants, they can report inaccurate results to the system causing incorrect water chemistry, which could har m people or equipment. Check the IntelliChem ® Controller main status display each day to ensure there are no Alar m messages. See “Troubleshooting” on page 46 f or more information. When using IntelliChem with a pool pump timer: The Association of Pool and Spa Professionals (APSP) recommends that all water in a residential pool pass through the filtration system at least once every 12 hours (referred to as pool water turnover). However, many factors have an effect on actual pump and filter system r un times. Pool size, source of water, direct sun light, indoor/outdoor , screened and unscreened, filtr ation system, cold or hot w eather, swimmer load, rain, organic debris, algae, etc., are all factors which contribute to either more or less pool pump and filter system run times. Because of these differences, it is extremely difficult to set an initial run time (starting point) for the pool pump and chlorinating system. Try initially setting the pool pump timer to 12 hours . It will take a few days to get just the right amount pool pump operating time. When the Chlorinator is wired with a pool pump timer (see page 6) results will vary greatly from one pool installation to the next, so this should be discussed with either the pool builder or your pool professional. Using CO2 for pH Control Plaster pools and pools using salt-chlorine generators typically cause a slow pH rise which must be managed. With the IntelliChem ® controller muriatic acid or carbon dioxide (CO2) is dispensed into the filter system’s return water as needed until the Flow Cell pH sensor detects the proper pH level. Using CO2 for pH control eliminates the need to handle and stored acid and can be a safer method. As CO2 gas is injected into the pool water, it dissolves and creates carbonic acid. This weak acid is very efficient at lowering pH with the added benefit of self-limiting if the CO2 is over-fed. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 1 Overview The INTELLILCHEM® Water Chemistry Controller is a pH and ORP sensing device that dispenses correct amount of chlorine or bromine, muriatic acid or CO2 gas. The IntelliChem controller provides continual analysis of your swimming pool water sanitation and pH levels, providing real-time status information to dispense the proper amount of muriatic acid (pH reducer) and chlorine or bromine for the correct sanitization and pH balance. The IntelliChem controller operates with or without a salt chlorine generator to provide a self-replenishing supply of chlorine generated from salt. The IntelliChem controller can also connect to carbon dioxide (CO2) liquid gas tanks to lower pH in your swimming pool water. When CO2 dissolves into water it produces weak neutral bicarbonate salts which reduces pH. CO2 is environmentally friendly and produces no secondary pollution into the treated water by salts such as chlorides or sulfates. CO2 does not corrode metal equipment and does not require any special piping. The IntelliChem controller supports Pentair Aquatic Systems (“Pentair”), EasyTouch®, IntelliTouch® and SunTouch® automation control systems for pH and ORP control. The IntelliChem controller also supports IntelliChlor® salt chlorine generator (SCG) to help manage your pool water sanitizer levels. Operating the IntelliChem Controller Before operating the IntelliChem controller, it’s important to test and adjust your pool water chemistry to the recommended pool industry levels found in this manual (see page 19). If you are using an IntelliChlor salt chlorine generator, adjust the salt levels to the recommended levels in the IntelliChlor (SCG) Installation and User’s Guide (P/N 520589). During normal operation, no user input is required, the IntelliChem controller will automatically sense ORP and pH levels. The current ORP and pH levels are regularly displayed on the control panel LCD display. Use the pH Settings or ORP Settings buttons to view or adjust supply levels. The “Auto Setup” feature provides screen prompts for first-time setup or standard configurations such as setup reminder times, calculating feed times, proportional limits and alarms. For details, see page 6. First Balance Your Pool Water IMPORTANT: To help keep your pool water balanced follow these steps: 1. Use a Test Kit (with fresh testing reagents) to measure the pH, alkalinity, and calcium hardness of the pool water. For greater accuracy, Pentair recommends the AcuCheck3 Test Kit to measure pH, chlorine ppm, and alkalinity levels (P/N 745000110). “Balanced” water has proper levels of pH, Total Alkalinity and Calcium Hardness. This “balanced” water is neither corrosive or scaling. The pH (0-14) value is the scale of relative acidity or alkalinity. Recommended pH range is from 7.2 to 7.6. The IntelliChem controller default pH value is 7.5 (see page 12). 2. Be sure the pool chlorine level is balanced. Ideal free chlorine level should be between 1.0 - 3.0 parts per million (ppm). 3. Use the online Langelier Saturation Index (LSI) calculator to diagnose the water balance in your pool or the IntelliChem controller built-in LSI calculator (see page 24-27). Refer to: http://www.pentairpool.com/pool-owner/resources/calculators/langelier/ Note: A Saturation Index value of 0 indicates the water is chemically in balance. If the Index is a minus (-) value, corrosive tendencies are indicated. If the Index is a plus (+) value, scale-forming tendencies are indicated. A Saturation Index value between +0.5 to -0.5 is considered satisfactory in a swimming pool. See Saturation Index menu on page 24. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 2 Operator Controls, Indictor and Alarm LEDs CONTROL PANEL DESCRIPTION 2 3 pH SETTINGS ORP 1 pH OK 7.46 Mixing 00:07:03 ORP OK 450 Mixing 00:07:54 9 SETTINGS 4 FLOW ALARM 5 MENU Select 6 7 8 Control Buttons and LEDs: 1 Liquid Crystal Display (LCD) with backlighting: Displays system status information and the IntelliChem® Controller main menu. Display backlight and menu on and off time (30 seconds to 24 hours) can be set via the “LCD Timeout” menu feature. See “Configuration” menu page 17). Display viewing modes: Select between two display modes: Basic: pH and ORP status with alarms messages. Advanced: pH, ORP, status, alarm messages and process timers. 2 pH Settings button: Access the pH settings (see page 3). 3 ORP Settings button: Access the Oxidation Reduction Potential (ORP) settings (see page 3). 4 Flow LED: Green LED on indicates flow is detected. LED will blink during flow delay. LED off indicates no flow in the system. If flow is not present, no chemical feeding or IntelliChem controller activity is allowed. LED brightness can be adjusted via the Configuration “Display Mode” menu (see page 17). 5 Left arrow button: Scroll through sub-menu items or move cursor left when editing a setting. 6 Menu button: Access the main menu (see page 11). While in menu mode, used to exit a menu level. All items are saved as soon as they are changed. 7 Right arrow button: When in menu mode, selects menu main and sub-menu item, scroll through sub-menu items or move cursor right when editing a setting. 8 Alarm LED: LED is on if an alarm condition occurs. Display shows alarm message and status (see page 48). LED brightness can be adjusted via the Configuration “Display Mode” menu (see page 17). 9 Up/Down arrow button: When in a menu mode, use / to scroll through main menu and sub-menu items, increase, decrease or change a setting or value. Also, used for moving to next sub-menu page 1/2 - 2/2. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 3 pH Settings and ORP Settings Buttons pH Dosage (dispense acid) DO NOT manually feed pH (acid) and ORP sanitizer (chlorine) at the same time without sufficient water flow through the piping system. Combining these two chemicals without sufficient water flow for mixing will result in the formation of hazardous gas. This menu item will be displayed as Override [Wait] during no-flow and flow-delay time period. pH SETTINGS ORP SETTINGS pH Settings button: Press the pH Settings button to access the pH dosage settings. pH Settings Override [Dose] Level Gauge: 5 Limit cleared ORP Settings button: Press the ORP Settings button ORP Settings to access the Oxidation Reduction Potential (ORP) Override [Dose] settings. The ORP is the sanitization quality of the Level Gauge: 5 Limit: [Clear ] water of a given solution. Note: To exit pH Settings and ORP Settings, press the MENU button. Password Protect: The pH Settings and ORP Settings screens are not accessible when the Password Lock is set to “ALL”. Set the Password Lock to “OFF” or “MENU” to access these screens (see page 5). Override (pH): Press the / Right or Left arrow button to toggle between “Dose” or “Stop”. Select “Dose” to dispense muriatic acid or CO2 and select “Stop” to stop dispensing acid or CO2 (pH Settings LED is on). To exit, press the MENU button or press the Down button to select the “Level Gauge” feature. The Override feature is not available when CO2 is setup to “Feed to Setpoint.” Override (ORP): Press the / Right or Left arrow button to toggle between “Dose” or “Stop”. Select “Dose” to dispense chlorine (or bromine) and select “Stop” to stop dispensing chlorine (ORP Settings LED is on). To exit, press the MENU button or press the Down button to select the “Level Gauge” feature. The Override feature is not available when IntelliChlor is setup to “Feed to Setpoint.” Level Gauge indicator: Press the / Up/Down button to select this feature. The level gauge (volume based) and hour glass (time based) icon is a visual representation of the amount of acid (pH Settings) or chlorine (ORP Settings) available in the container. Press / six times to fill the gauge (container full). The indicator displays six horizontal bars when full. The level gauge is not available if the doser is unable to determine the pump dispense rate, the supply volume, or if there is no supply “reminder” set up (see page 13-15). The gauge is displayed as an “hour glass” if the supply is based on time rather then volume (see page 6) Limit [Clear]: Press the / to select this feature. Press the / to clear the current dosage limit timer. After pressing the button, “CLEARED” is displayed, indicating that the current dosage limit is cleared. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 4 IntelliChem® Controller System Power Up Screens IntelliChem® Controller v1.040 04/01/12 Pentair Aquatic Systems Power-up Sequence: During power-up the IntelliChem® Controller displays the initialization screens before the main status screen is displayed. During this initial power up sequence, the IntelliChem controller performs an internal self test and continues with a system calibration. The first screen includes the current software version and date. AUTO CALIBRATION AUTO CALIBRATION is displayed each time IntelliChem is powered up. AUTO CALIBRATION pH 6.35 7.65 OK ORP 738 398 OK ***PASSED*** In the next auto-calibration sequence the pH and ORP meters are tested with on-board circuitry and calibrated to the built-in reference devices. An out-of-tolerance condition is immediately reported as an error so the user can have the unit serviced. IntelliChem Auto __Setup Wizard__ Press MENU to go to each new step The very first time IntelliChem controller is powered up and after a factory reset, the Auto Setup Wizard start screen is displayed. Otherwise access the wizard from the main menu (see page 6). Awaiting POWER&FLOW DELAY H:00 M:14 S:18 please wait... The normal start up screen will simply be this one, awaiting Power On & Flow Delay. The countdown timer shows the remaining time before the unit starts reading the probes and controlling the doser. pH Main Status Screen: After IntelliChem controller has completed the Flow Delay the main status screen displays the measurements of the connected pH and ORP sensors. OK 7.5 ORP OK 450 INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 5 Set Password Protect The password protect feature prevents access to certain menus and prohibits all menu changes and manual feeds. For more information, see Set Password on page 18. To set the password protect: Set Password PW [1234] Lock [Off ] Locked - Please enter password > 1234 1. Press MENU / Configuration and / Set Password. 2. Set Password (PW): Press the / Up/Down arrow button to select the first password digit (0-9). 3. Press the / Right/Left arrow button to move the cursor to the next digit. 4. Press the / Up/Down arrow button to select the second password digit. Repeat steps 3 and 4 for the third and fourth password digit. 5. Press the Right arrow button to move the cursor to the Lock Menu setting. 6. Press the / Up/Down arrow button to select OFF: Do not enable control panel button lockout. ALL: Lockout MENU, pH Settings and ORP Settings buttons). Tank Levels cannot be changed. MENU: Lockout MENU button (not pH Settings and ORP Settings buttons). Setpoints or Sat Index values TA, CYA, CH cannot be changed. 7. To exit, press the MENU button (press three times to return to the main screen. Tip: Setting the password 0000 allows you to enter a protected screen by pressing MENU. Also, once the password is entered, access is granted for the duration specified by the Menu timeout setting in the Configuration/Display Mode menu (see page 17). Password Protect and IntelliTouch®, EasyTouch® and SunTouch® Control Systems Note: If the password lock is enabled from IntelliChem controller it will also be locked out on the IntelliTouch, EasyTouch or SunTouch automation control system. When IntelliChem is controlled by the IntelliTouch, EasyTouch or SunTouch control system, if the password is set and locked on the IntelliChem, it cannot be changed from the automation control panel. To change a “LOCKED” password from the automation system, enter the password on the IntelliChem controller, it will remain active for the Menu Timeout MM:SS period. During that time, the automation system will be able to set the appropriate settings, just as you would from the IntelliChem controller front panel. Receiving updated settings from automation will continue to extend the Menu Timeout, just as if you’re accessing the menu on the IntelliChem controller itself. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 6 H CO2 OR The- displays shows t Display Modes The main IntelliChem® Controller status screen can be setup to display basic or advanced system information. To setup the Display Mode, see “Configuration” menu on page 17. The Basic display mode shows the current pH and ORP measurements including a message describing any existing pH (line two) and ORP (line four) alarms. The Advanced display mode shows all the current measurements and alarm messages as well as dose and mix timers showing the progress of those processes. Basic display mode pH >OK 7.4 -.72 Scaling ORP OK 730 Monitoring The Basic mode displays the current pH and ORP measurements (pH in10th and ORP in 5mV) with any alarms Note: Alarms are displayed on all Basic and Advanced modes. >OK or <OK is displayed as soon as the value exceeds alarm trip point. That is replaced with “HIGH/LOW” after the Advanced display mode Displays three different Alarms. The example screen shows: Dose limit, high reading and chemical tank low alarm. These pH HIGH 7.91 can co-exist. The advanced mode displays the current pH and pH Dose Limit ORP high precision measurements (extra digit. e.g. pH=100th ORP OK 683 ORP=1mV resolution), alarms, tank levels, process messages Mixing 00:07:54 and timers. Basic and Advanced Display with Error Messages NO FLOW DETECTED If IntelliChem detects the pool water circulation pump is not active, a NO FLOW message is displayed. ORP and pH values Check pump, flow are not measured when there is no flow, and therefore not Cell, filter, displayed. and valves. Auto Setup Use the Auto Setup feature for first-time setup or standard configurations. Follow the onscreen prompts and enter information about your system configuration (pH/ORP internal or external pumps, pool size, filter time, chemical container size etc). IntelliChem uses this information to automatically setup reminder times, calculate feed times, proportional limits and alarms. The following describes the Auto Setup screen. Press the MENU button to access the Auto Setup menu. To change a menu setting or value press the / Up/ Down arrow button. Press the MENU button to save each selection. Press MENU / Auto Setup To exit Auto Setup, press IntelliChem Auto __Setup Wizard__ Press MENU to go to each new step Dosing will resume when you _exit this menu_ Press any button Previous Values: Use to recalculate new dose times etc., if no custom settings exist. Not recommended for custom settings; use the menu directly to make these changes. Reset All: Make major configuration changes that may have conflicts with previous settings. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide Would you like to use previous values? [Yes | Reset All] 7 Auto Setup (Continued) What is your What size is the Hardware Setup? body of water? pH ORP Volume: 10.0K [L_Pump R_pump] Units: gal-US Press the / Up/Down arrow button to scroll through the six configurations. How long does What is the pH your filter run? Container Size? Daily:H:08 M:00 1.00 gal-US Gauge: 6 Press the MENU select next screen Enter ORP info on next screen. What is your What size is the How long does What is the pH Hardware Setup? body of water? your filter run? Container Size? pH ORP Volume: 10.0K Daily: H:24 M:00 1.0 gal-US [L_Pump ICHLOR] Units: gal-US Gauge: 6 What is your What size is the How long does What is the pH Hardware Setup? body of water? your filter run? Container Size? pH ORP Volume: 10.0K Daily: H:24 M:00 1.0 gal-US [L_Pump EX_IC*] Units: gal-US Gauge: 6 Enter doser pump What is your What size is the How long does Hardware Setup? rated output for body of water? your filter run? pH: 1 GPD (1-400) pH ORP Volume: 10.0K Daily: H:08 M:00 ORP: 1 GPD [L_Pump RELAY1] Units: gal-US (*) EX_IC: IntelliChlor® Salt Chlorine Generator What is the pH (Commercial model only) Output on RELAY #1 Container Size? 1.0 gal-US Gauge: 6 Enter ORP info on next screen. What is your What size is the Enter doser pump How long does Hardware Setup? rated output for body of water? your filter run? pH ORP Volume: 10.0K pH: 1 GPD (1-400) Daily: H:08 M:00 [RELAY2 ICHLOR] Units: gal-US Select Use Time (“0”) What is the pH if the doser pump’s Container Size? GPD (gallons-per1.0 gal-US day) feed rate is Gauge: 6 unknown. Enter doser pump What is your What size is the How long does Hardware Setup? rated output for body of water? your filter run? pH: 1 GPD (1-400) pH ORP Volume: 10.0K Daily: H:08 M:00 [RELAY2 RELAY1] ORP: 1 GPD Units: gal-US What is the pH Container Size? 1.0 gal-US Gauge: 6 Enter ORP info on next screen. Continue on next page INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 8 Auto Setup (Continued) What is your How long should Hardware Setup? CO2 dose be pH ORP H:00 M:05 S:00 [CO2/R2 L_PUMP] How long does your filter run? Daily: H:08 M:00 pH Chem Reminder in: H:00 M:00 What is the pH Container Size? 1.0 gal-US Gauge: 6 What size is the body of water? Volume: 10.0K Units: gal-US How long should What is your What size is the each CO2 dose be? Hardware Setup? body of water? H:00 M:05 S:00 pH ORP Volume: 10.0K [CO2/R2 ICHLOR] Units: gal-US Daily: H:08 M:00 YES Finished Setup. Verify your new settings in the pH & ORP menus! Balance water chem istry before beginning automatic control NO Is your pool water balanced? [No] How long does your filter run? IntelliChem System Default Values pH pH Set Point: 7.5 pH Alarm High: 7.8 pH Alarm Low: 6.8 pH Alarm Delays: 5 min. for both Sensitivity: Low (Off for CO2) ORP ORP Set Point: 700 ORP Alarm High: 750 ORP Alarm Low: 650 ORP Alarm Delays: 5 min. for both Sensitivity: Low (Off for IntelliChlor) pH Lockout:7.8 Miscellaneous Default Values Display Mode:Basic Control Panel LED Brightness: 10% Menu Timer:M:02 S:30 Menu Backlight Timer: M:00 M:20 Power-On Delay: 14 minutes Flow Switch Delay: 1 minute Dose Priority: Simultaneous dosing Password 1234 - Lock = Off INTELLICHEM® Water Chemistry Controller Installation and User’s Guide pH Chem Reminder in: H:00 M:00 9 MENUS MAIN SCREEN PH MENU (page 11) pH Dosage (Page 1/2) Dosage (For liquid; Volume/Time): (For CO2; Time or to set point): Mixing Time: H:24 M:59 pH Dose by Volume (Page 2/2) Dose: [0-9999], Limit: [0-64350], Units: [oz/ml], Clear [Manual] pH Dose by Time (Page 2/2) Dose: [00:00:00], Limit: [00:00:00], Clear: [Power-On] pH Dose to Setpoint (Page 2/2) Limit: [00:00:00], Clear: [24hr Flow] pH Setpt: 7.5 (use Left/Right button to adjust pH set point) pH Tweak - reading = 7.xx tweak: 0.0 (+/- 0.3) pH Supply (Page 1/2) Units: gal-US/gal-UK/Liters/Time, Chemical: [Acid, pH-, Base, pH+] Page 2/2 - Capacity: 0.000-200.00 gal-US/galUK/Liters - Gauge: Egg timer or tank gauge Page 2/2 Time: Reminder in: H:100 M:00 Sensitivity: - [Low/High/Off] - Full Dose at 0.5pH (Low - Liquid, CO2), (High 0.2pH from set point). pH Alarms: Page1/2 High 7.8 - Delay 00:05:00 - Page 2/2 Low: 6.8 Delay 00:05:00 ORP MENU ORP Dosage (Page 1/2) Dosage (For liquid; Volume/Time): (For SCG; Time or to set point): Mixing Time: H:24 M:59 ORP Dose by Volume (Page 2/2) Dose: [0-9999], Limit: [0-64350], Units: [oz/ml], Clear [Manual] ORP Dose by Time (Page 2/2) Dose: [00:00:00], Limit: [00:00:00], Clear: [Power-On] ORP Dose to Setpoint (Page 2/2) Limit: [00:00:00], Clear: [24hr Flow] ORP Setpt: 700 (use Left/Right button to adjust ORP set point) ORP Tweak - reading = xxx tweak: 0.0 (+/- 50mV) ORP Supply (Page 1/2) Units: gal-US/gal-UK/Liters/Time, Chemical: [Chlorine/Bromine] Page 2/2 - Capacity: 0.000-200.00 gal-US/galUK/Liters - Gauge: Egg timer or tank gauge Gauge: Egg Timer or tank gauge - Page 2/2 Time: Reminder in: H:100 M:00 Sensitivity: - [Low/High/Off] - Full Dose at 50 mV ORP (Low - Liquid), (High 20 mV from set point, Off (IntelliChlor OFF) ORP Alarms: Page1/2 High 750 - Delay 01:00:00 - Page 2/2 Low: 650 Delay 02:00:00 (page 14) SAT INDEX See page 24 for details - pH: 7.5 - Temp: 00°F - CH: xxx - SLT: xxx - TA:xx = CYA: xx Recalc/Tab: AUTO SETUP See page 6 for details CONFIGURATION Pool Details:Volume: 0.2K-230K (200-230,000 Liters max) Units: Gal US (gal-US/gal-UK/Liters), Daily Hrs/Mins Display Mode: Display Mode: Basic/Advanced, Brightness Front LEDs: (0-100%), Menu/BkLt Hrs/Mins. (24 hrs -30sec.) Delays: Power-on: 1-60 mins. (15min default) - FlowSwitch: 1-60 mins. (1 min default) Doser/Probe: Seconds 0,15,30,60secs. Set Password: PW [1234] - Lock [OFF/MENU/ALL] Preferences: pH Lockout: 7.8, Preferences 2/2: Saturation Index, Alarm: +/- 0.3, Dose Priority: [Simultaneous pH Priority] Diagnostics: Software Rev, Meter Test {Auto Calibration), Probe Test (Open Probe Test) Timers, Chlorinator, Status Codes, Factory Reset, Self Test Sequence Hardware: pH Control: 1/2 Doser Type [Internal Pump, External/Relay, CO2 Ext/Relay, None] - pH Control 2/2 Flow: xx GPD See page 22 for details (page 17) INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 10 Navigating IntelliChem® Controller Menus The following examples show how to navigate the main menus and sub-menus. Press the MENU button to access the main menu. Press the Right arrow button to select a menu item and select items in a sub-menu. Press / to select previous/next item on a page. To change a menu setting or value press the / Up/Down arrow button. Press the MENU button to exit and return to the previous menu items. Note: Settings are automatically save when changed. Example: To change the pH dosage settings (pH Dosage screens 1/2 and 2/2): Press MENU / pH Menu pH Dosage pH Menu ORP Menu Saturatn Index Auto Setup ORP Menu Saturatn Index Auto Setup Configuration Dosage pH Setpt: 7.5 pH Tweak pH Supplies pH Dosage 1/2 Dose: by Volume Mixing Time: H:00 M:59 pH Dosage 2/2 Dose Limit Units 3 21 [oz] Clear [Power-On] pH Dosage 1/2 Dose: by Volume Mixing Time: H:09 M:59 pH 2. Press the Right arrow button to select the pH menu. 3.Press arrow button to select pH Dosage (page 1 of 2). Press / to toggle between pH Dosage page 1/2 and page 2/2. 4. From pH Dosage page 1/2, press the to select Dose (feed method). To change the feed method press / to change the selection: “by Volume” or “by Time”. pH pH Menu ORP Menu Auto Setup Configuration 1. Press the / Up/Down arrow button to scroll through the main menu items. For this example choose pH menu. OK 7.46 Mixing 00:07:03 ORP OK 450 Mixing 00:07:54 5. Press the to select the next item. The cursor moves down to the “Mixing Time” hours setting (H:00). 6. Press the / to adjust the Mixing Time hours between feeding acid. Press to select the minutes. Press / to adjust the minutes. After adjustment, the display shows the new setting. Note: Press either / button to scroll forward or backwards within this sub-menu. 7.Select 1/2 page indicator. Press the / buttons to select the next pH Dosage screen (2/2). 8.Use / buttons and / buttons to select and change the “Dose” (amount of liquid dispensed before waiting for a mix time), Limit (amount of liquid dispensed in one day, Units (apply to dose and limit) and clear dose limits setting. 9. Press the MENU to return to the previous pH Dosage page 1/2 menu items. 10. Press the MENU again to exit pH Dosage menu. Note: All settings are immediately save when changed. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 11 Menu Description pH Menu Menu ORP Menu Saturatn Index Configuration pH Dosage pH Setpt: 7.2 pH Tweak pH Supplies by Volume pH Dosage 2/2 Dose Limit Units 1200 64100 [mL] Clear [Manual] by Time pH pH Dosage Dose: by Time Mixing Time: H:00 M26 pH Dosage 2/2 Dose 00:33:45 Limit 04:14:00 Clear [Power-On] 1/2 by Setpoint pH Dosage 2/2 Dose to Setpoint Limit 00:08:00 Clear [24hr ] To access the pH Menu: Press MENU pH Menu pH Dosage - The ph Dosage screen 1/2 displays the current dose method (by Volume, Time or to Setpoint). pH Dosage (for Internal and External Pumps) pH Dosage (page 1/2) Mixing Time: Select the amount of time in hours and minutes that the IntelliChem® Controller will wait in between pH feeding. It should be set to allow sufficient mixing time for the chemicals to become distributed throughout the pool. The pH Mixing Time is set by Auto Setup. Dose (by Volume/Time): Choose the feed method: “by Volume” and “by Time” are available choices for liquid dosers, as determined by the hardware setup. If CO2 is selected, then the available choices are “by Time” and “To Setpoint”. pH Dosage (page 2/2) Dose (Volume): Displays the current dose size (0-9999) in ounces [oz] or milliliters [ml]. Set the amount of ounces (or milliliters) that the IntelliChem controller will feed pH (acid) each time the IntelliChem controller calls for pH chemicals. The Dose (Volume) is set by Auto Setup wizard based on pool volume and filter run time. Dose (Time/Setpoint): Displays the current pH dose (feed) time. Sets the amount of time in hours, minutes and seconds that the IntelliChem controller will feed pH (acid) each time the IntelliChem controller calls for pH chemicals. The pH dose time is set by Auto Setup. The Dose (Time) is set by Auto Setup wizard based on pool volume and filter run time. Dose (to Setpoint) does not have a dose amount, only a time limit. Limit (Time/Volume): Displays the current feed limit. Sets the maximum amount of time/volume in hours, minutes and seconds or volumetric units that will be allowed to feed pH chemicals. As a safety feature, the IntelliChem controller will only allow a certain amount of pH chemicals to feed into the system in a 24 hour period. Set the maximum amount of time in hours (0-24) that will be allowed to feed. The IntelliChem controller tracks each dose time, and adds them together. When the maximum dose time is reached or exceeded, the ORP feed system is prevented from feeding until the next 24 hour period begins, or when the feed timers are cleared manually. The default pH Limit is based on a safe limit of 2 ppm of the size of the pool, up to a 5 oz maximum. The Limit (Time/Volume) is set by Auto Setup wizard based on pool volume and filter run time. Continue on next page. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 12 pH Menu (Continued) pH Dosage (page 2/2) Continue Clear: Select Power-On to clear the pH dose limit time when IntelliChem® Controller is powered on. Select Manual to manually clear the pH dose limit timers and select 24 Hrs to clear timers automatically each 24 hour period of continuous operation. To protect the pool water, IntelliChem controller will automatically shutdown pH and ORP feed control and display an alarm message if IntelliChem controller (or any other dispensing device) runs non-stop for more than the selected Limit time or volume. This prevents IntelliChem from non-stop feeding pH reducer, because of a sensor error or external problem with the pool. This allows you to evaluate the pool chemistry before continuing with pH feeding. pH Set Point Displays the current pH set point value. Adjust the pH set point to meet pool and spa chemistry standards. The adjustable range is from 7.2 to 7.6 in increments of 0.1. The default pH set point value is 7.5. To adjust the acid feed pH set point: Press MENU pH Menu pHSetpt Press / to decrease or increase the current pH set point value. Note: When using CO2, parameters are the same as above. pH Tweak The exact reading of each individual pH sensor can vary because of water makeup and variances in probe condition age, etc. The pH Tweak menu feature allows you to adjust the pH sensor reading to match the manual reading taken. The adjustable range is +/- 0.3. After adjusting the pH value, the main screen should now display the same value as the manual reading. To adjust the pH sensor level: Press MENU / pH Menu pH Tweak The current value is displayed (reading = x.xx). Press / to adjust the pH sensor level (+/- 0.3). To remove the tweak, set the level back to 0 (zero). pH Supplies pH Supply (page 1/2) Units: Select gal-US, gal-UK, Liters or Time (hours/minutes)*. Chemical: Use Acid, (pH -) or Base (pH+). 1/2 pH Supply 2/2 Capacity: 4.00 gal-US Gauge: 3 pH Supply Reminder in: H:1000 M:00 Gauge: INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 2/2 6 pH Supply Unit: USGal Chemical: [Acid, pH-] 13 pH Menu (Continued) pH Supply (page 2/2) Capacity: Select from 0 to 200 maximum gal-US, gal-UK, or Liters. *Time (Reminder in: H:xxx M:xx) If the supply Units were set to Time, the Capacity feature becomes a Reminder feature, as in an egg-timer. This can be used to trigger an alarm, based on cumulative feed times as to when to check the CO2 cylinder. Set the reminder time in hours (0-8760) and minutes (00-59) on ORP Supply page 2/2. Note: Entering the hours and minutes time (H:00 M:00) will display the hour glass icon on the main screen. Level Gauge (liquid only): Displays level gauge when using liquid chemical doser. Tank icon symbol is used for liquid chemical configurations that include valid supply and doser feed rate information. pH Sensitivity The IntelliChem® Controller can adjust the feed times for pH depending on how close the current reading is to the set point. This helps to prevent overshooting and makes it easier for the IntelliChem controller to reach the exact set point. Low= (default) Full dose at 0.5 pH above setpoint High= Full dose at 0.2 pH above setpoint Off= Full dose at 0.005 pH above setpoint For example: When set to LOW (full dose at 0.5 above setpoint), if pH setpoint is 7.2 and pH reading is 7.7 or above, a full dose amount is dispensed. As the pH comes closer to setpoint, say 7.45 (0.25 above setpoint - or- half the 0.5 pH value), the dispensed amount will be 1/2 of the specified dosage. And, at 0.05 (1/10th of 0.5 value) above setpoint (7.25), the dosage will be 10% of that specified in the dosage menu. In that case, if the dosage was specified to be 10 ounces, IntelliChem controller will dispense only 1 ounce at a time. This can be confusing to someone who is watching the IntelliChem controller because it will appear to not be dosing the full amount; therefore, in the Advanced display mode, the process timer will be shown as “%Dosing 0.1 oz”, the “%” indicating that the dosage is reduced due to this Sensitivity feature. To set the pH Sensitivity level: Press MENU - pH Menu / pH Sensitivity pH Alarms The IntelliChem controller automatically displays a screen message indicating the pH level has reached or exceeded the HIGH (7.8) or LOW (6.8) pH alarm level settings. The IntelliChem controller will automatically set a high and low alarm for the pH level. The Delay time is the amount of time between the detected alarm condition and when the IntelliChem controller displays the alarm message on the main screen. The Delay setting is adjusted in increments of 15 seconds. To set the pH alarm “High” level and “Delay” time (page 1/2): Press MENU pH Menu pH Alarms / pH Alarms / (page 1/2 is High Level Alarm, page 2/2 is Low Level Alarm) Press to select the alarm, High level and Delay Time (00:50:00). To set the pH alarm “Low” level and “Delay” time (page 2/2): Press MENU / pH Menu pH Alarms / Low / Delay (2/2) Press / to change pH alarms Low level and Delay Time (00:05:00). INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 14 ORP Menu ORP Dosage (dispense chlorine or bromine) by Volume ORPDosage 2/2 Dose Limit Units 1200 64100 [mL] Clear [Manual] ORP Dosage ORP Setpt: 700 ORP Tweak ORP Supply pH Menu Menu Saturatn Index Configuration ORP ORP Dosage Dose: by Time Mixing Time: H:00 M26 by Time ORPDosage 2/2 Dose 00:33:45 Limit 04:14:00 Clear [Power-On] 1/2 by Setpoint ORPDosage 2/2 Dose to Setpoint Limit 00:08:00 Clear [24hr ] To access the ORP Menu: Press MENU ORP Menu ORP Dosage - The ORP Dosage screen 1/2 displays the current dose method (by Time or to Setpoint). ORP Dosage (for Internal and External Pumps) ORP Dosage (page 1/2) Mixing Time: Select the amount of time in hours and minutes that IntelliChem will wait in between ORP dosing. It should be set to allow sufficient mixing time for the chemicals to become distributed throughout the pool. The ORP Mixing Time is set by Auto Setup. Dose (by Volume/Time): Choose the feed method: “by Volume” and “by Time” are available choices for liquid dosers, as determined by the hardware setup. If IntelliChlor (SCG) is selected, then the available choices are “by Time” and “To Setpoint”. ORP Dosage (page 2/2) Dose (Volume): Displays the current dose size (0-9999) in ounces [oz] or milliliters [ml]. Set the amount of ounces (or milliliters) that IntelliChem will dose ORP (chlorine/bromine) each time IntelliChem calls for ORP chemicals. The Dose (Volume) is set by Auto Setup wizard based on pool volume and filter run time. Dose (Time/Setpoint): Displays the current ORP dose (feed) time. Sets the amount of time in hours, minutes and seconds that IntelliChem will feed ORP (chlorine/bromine) each time IntelliChem calls for ORP chemicals. The ORP dose time is set by Auto Setup. The Dose (Time) is set by Auto Setup wizard based on pool volume and filter run time. Dose (to Setpoint) does not have a dose amount, only a time limit. Limit (Time/Volume): Displays the current feed limit. Sets the maximum amount of time/volume in hours, minutes and seconds or volumetric units that will be allowed to feed ORP chemicals. As a safety feature, the IntelliChem will only allow a certain amount of ORP chemicals to feed into the system in a 24 hour period. Set the maximum amount of time in hours (0-24) that will be allowed to feed. IntelliChem tracks each dose time, and adds them together. When the maximum dose time is reached or exceeded, the ORP feed system is prevented from feeding until the next 24 hour period begins, or when the feed timers are cleared manually. The default ORP Limit is based on a safe limit of 2 ppm of the size of the pool, up to a 5 oz maximum. The Limit (Time/Volume) is set by Auto Setup wizard based on pool volume and filter run time. Clear: Select Power-On to clear the ORP dose limit time when IntelliChem is powered on. Select Manual to manually clear the ORP dose limit timers and select 24 Hrs to clear timers automatically each 24 hour period of continuous operation. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 15 ORP Menu (Continued) ORP Set Point Displays the current ORP set point value. Adjust the ORP set point to meet pool and spa chemistry standards. The adjustable range is from 400 to 800 in increments of 10. The default ORP set point value is 700. To adjust the ORP set point: Press MENU ORP Menu ORP Setpt Press / to decrease or increase the current ORP set point value. Note: When using IntelliChlor SCG, parameters are the same as above. ORP Tweak The exact reading of each individual ORP sensor can vary because of water makeup and variances in probe condition age, etc. The ORP Tweak menu feature allows you to adjust the ORP sensor reading to match the manual reading taken. The adjustable range is +/50mV. After adjusting the ORP value, the main screen should now display the same value as the manual reading. To adjust the ORP sensor level: Press MENU / pH Menu ORP Tweak The current value is displayed (reading = x.xx). Press / to adjust the ORP sensor level (+/- 50 mV). To remove the tweak, set the level back to 0 (zero). ORP Supplies ORP Supply (page 1/2) Units: Select gal-US, gal-UK, Liters or Time (hours/minutes)*. Chemical: Use Chlorine or Bromine. 1/2 ORP Supply 2/2 Capacity: 4.00 gal-US Gauge: 3 ORP Supply Reminder in: H:1000 M:00 Gauge: 2/2 6 ORP Supply Unit: USGal Chemical: [Chlorine] ORP Supply (page 2/2) Capacity: Select from 0 to 200 maximum gal-US, gal-UK, or Liters. *Time (Reminder in: H:xxx M:xx) If the supply Units were set to Time, the Capacity feature becomes a Reminder feature, as in an egg-timer. This can be used to trigger an alarm, based on cumulative feed times as to when to clean the SCG plates. Set the reminder time in hours (0-8760) and minutes (00-59) on ORP Supply page 2/2. Note: Entering the hours and minutes time (H:00 M:00) will display the hour glass icon on the main screen. Level Gauge (liquid only): Displays level gauge hour when using liquid chemical doser. Tank icon symbol is used for liquid chemical configurations that include valid supply and doser feed rate information. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 16 ORP Menu (Continued) ORP Sensitivity IntelliChem can adjust the feed times for ORP depending on how close the current reading is to the set point. This helps to prevent overshooting and makes it easier for IntelliChem to reach the exact set point. Low= (default) Full dose at 50mV below setpoint High= Full dose at 20mV below setpoint Off= Full dose at 1mV below setpoint For example: When set to LOW (full dose at 50mV below setpoint), if ORP setpoint is 700 and ORP reading is 650 or below, a full dose amount is dispensed. As the ORP comes closer to setpoint, say 675mV (25mV below setpoint - or- half the 50mV value), the dispensed amount will be 1/2 of the specified dosage. And, at 695 (1/10th of 50mV value) below setpoint (700), the dosage will be 10% of that specified in the dosage menu. In that case, if the dosage was specified to be 10 ounces, IntelliChem will dispense only 1 ounce at a time. This can be confusing to someone who is watching the IntelliChem because it will appear to not be dosing the full amount; therefore, in the Advanced display mode, the process timer will be shown as “%Dosing 0.1 oz”, the “%” indicating that the dosage is reduced due to this Sensitivity feature. To set the ORP Sensitivity level: Press MENU - ORP Menu / ORP Sensitivity ORP Alarms IntelliChem automatically displays a screen message indicating the ORP level has reached or exceeded the HIGH (750 mV) or LOW (650 mV) pH alarm level settings. IntelliChem will automatically set a high and low alarm for the ORP level. The Delay time is the amount of time between the detected alarm condition and when IntelliChem displays the alarm message on the main screen. The Delay setting is adjusted in increments of 15 seconds. To set the ORP alarm “High” level and “Delay” time (page 1/2): Press MENU ORP Menu ORP Alarms / ORP Alarms / (page 1/2 is High Level Alarm, page 2/2 is Low Level Alarm) Press to select the alarm, High level and Delay Time (00:50:00). To set the ORP alarm “Low” level and “Delay” time (page 2/2): Press MENU / ORP Menu ORP Alarms / Low / Delay (2/2) Press / to change ORP alarms Low level and Delay Time (00:05:00). INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 17 Configuration Menu Pool Details From this menu, you can set your pool size, units to display and the daily run time which should match your daily pool pump filtration time. Volume: Pool volume (size). Select range is 200 - 230,000 gal (gal-US, gal-UK and Liters). Units: Select units to display in English (gal-US), (gal-UK) and Metric Liters. Daily: This daily run time is used for calculating dose and mix times. It is set and used in the Auto Setup script and should be the amount of time the pool pump/filter runs each day. To access the Pool Details menu: Press MENU Configuration Pool Details Display Modes Mode: Selects which display mode is displayed: Basic or Advanced, Basic mode displays the current pH and ORP levels with any alarms and fuel gauge if enabled. Advanced mode displays high resolution pH and ORP levels and process messages, timers (see page 6). LEDs: Adjusts the brightness level (0-100%) of the front panel LEDs. Menu: Adjusts the amount of time (minutes/seconds) the menu will be on each time the control panel is activated and also the time the entered password is valid. BkLt: Adjusts the amount of time (hours/minutes) the controller screen backlight will be on each time the control panel is activated. To access the display mode menu: Press MENU Configuration Display Press / to adjust display settings. Delays (minutes) Power-On: Sets the delay time from power up to the first display screen reading. The adjustable time is from 1 to 60 minutes. The default power on time is 14 minutes Flow Switch: Sets the delay time from when the Flow Switch is active to the first display screen reading. The adjustable time is from 1 to 60 minutes. The default flow switch delay time is one minute. Doser/Probe: Sets the delay time from when the Doser turns on to when it takes the next probe measurement. Adjustable time is 0 to 60 seconds. Default is 15 seconds. Use longer times to prevent interaction of doser from affecting the measurement. To access the delays menu: Press MENU Configuration Delays Press / to set the delay settings. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 18 Configuration Menu (Continued) Set Password The IntelliChem® Controller menus, the pH button and ORP button on the control panel can be password protected. Once a password has been set, the IntelliChem controller will not allow access to the menu system and no changes to be made without entering the password. For more information see page 5. PW: Enter a four digit password [0000]. Each digit can be assigned 0-9. Lock: Select OFF, MENU (password protect the main menu) or ALL (password protect all control panel buttons. Once the password is entered, access is granted for the duration specified by the Menu timeout setting in the Configuration/Display Mode menu. If the menus are locked, changes via the automation interface will also be locked out. To access the password menu: Press MENU Configuration Set Password Press / to select the digit and / move to next digit. Note: If you forget the password, first try the default password 1234, then call Customer Support for assistance. Preferences (1/2) To access the delays menu: Press MENU / Configuration Preferences Press / to adjust the following settings. Preferences 1/2 pH Lockout: 7.8 pH Lockout: is the pH reading at which IntelliChem will no longer dose sanitizer (Chlorine/ Bromine). Above pH of 7.8 it is generally understood that the ORP reading is suppressed and therefore will not be used to administer additional sanitizer. Just bringing the pH level down will raise the available chlorine and the effective ORP. At this trip point, an alarm message will be shown on the screen and ORP doses will cease. Range is 7.7 to 8.2, default is 7.8. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 19 Configuration Menu (Continued) Preferences (2/2) Preferences 2/2 Saturation Index Alarm: +/- 0.5 Delay: 00:30:0 Saturation Index Alarm: +/- 0.5: If the Saturation Index (SI) level is in the “Corrosive” or “Scaling” range, this feature allows you to enter a Saturation Index (SI) alarm threshold value between +/- 0.1 to +/- 0.9 (+/- 5 default). Select “Disabled” to disable the Alarm feature. Delay: The Alarm Delay feature sets the delay time before the SI Alarm (see above) message is displayed. Enter the delay time from 00:15:00 to 24:00:00 (30 minutes default). Note: Once the SI has passed the threshold for the delay period, an alarm message is displayed showing the Saturation Index Alarm (along with other pH alarms) that includes the value and description. pH >OK 7.44 -.72 Corrosive ORP OK 730 Monitoring pH >OK 7.44 +.32 Scaling ORP OK 730 Monitoring These alarm messages are also displayed on the IntelliTouch, EasyTouch and SunTouch control panel. Dose Priority To access the delays menu: Press MENU / Configuration Dose Priority Press / to select option. Dose Priority: pH Priority or Simultaneous. Depending on how the IntelliChem chemical dosers are plumbed and how much water is circulating in the system where the chemicals are injected into the water stream, it may be preferred to only feed Chlorine when Acid is not feeding. This would be the pH Priority setting. • Simultaneous allows both chemicals to feed at the same time - and can be used when both feed systems are not liquid chemicals or the injectors are separated by a safe distance in the water stream. DANGER: Combining liquid acid and chlorine can result in the formation of hazardous and explosive gas. • pH Priority will always feed acid first, and only during the acid mix time or general monitoring period will the IntelliChem feed the liquid chlorine sanitizer. If while feeding chlorine, the pH rises above setpoint, the ORP dose will be stopped and allow acid to feed. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 20 Configuration Menu (Continued) Diagnostics Software Rev: Displays the software revision. Meter Test: Performs an internal self-test of the pH/ORP meter and sensing circuitry. Ensures both circuits are performing properly First tests the High circuit in the uncalibrated state, waits for a button press, then tests the Low circuit and waits for a button press. Once these two tests complete, it proceeds with the self-calibration. A Pass or Fail message is displayed. If this test fails, disconnect power and check for water or dirt on the circuit board. Use a can of dry compressed air to clean the board if necessary. If the test continues to fail, contact technical support. Probe Test: This test takes approximately 30 seconds. Perform this test with the sensor cables and probes installed. Probes must be clean and in water. Possible results are : Both Probes Good pH: Good ORP:Bad pH: Bad ORP:Good pH: Bad ORP:Bad Timers: This displays the counters used for tracking the cumulating dose volume and/or time used in determining the Dose Limit. It shows: “PCs” PH cumulative dose limit timer in Days HH:MM:SS “Ocs” ORP cumulative dose limit timer in Days HH:MM:SS “ml” Milliliters of cumulative dose for Ph and Orp (0-9999) stops at 9999 ml “Run” the RUN TIME in Days, HH:MM:SS since powered up. If you need to know how much you’ve dosed during a day, or how long its been running that day, “Timers” will have this information. The cumulative times/ml get reset when you clear the dose limits, The Run Time clears on power-up. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 21 Configuration Menu (Continued) Diagnostics (Continued) Chlorinator: This screen displays the current IntelliChlor (SCG) status, salt (ppm) levels and error conditions. The hexadecimal status value is decoded and displayed in the brackets on the bottom line; multiple error conditions are shown by sequencing through the messages. This display can be used to determine if the SCG is connected and responding to the IntelliChem. If the IntelliChlor is connected, this display may show “Please wait 2-7 minutes for ppm”. This indicates the IntelliChlor is responding to initial contact but until water flow and sufficient salt level is reached, the IntelliChlor will not respond with further information like salt ppm and status. Sometimes it is helpful to cycle power on the IntelliChlor and wait 10 minutes for the green lights before it will respond with ppm and status information; it may not respond if the Salt or Cell lights are flashing red. If the Configuration / Hardware / ORP Control / Doser Type is set to IntelliChlor, the IntelliChem will control the IntelliChlor as it would a doser, actively turning it on (100%) for chlorine demand, and off (0%) when the ORP reaches the desired set point. For the Chlorinator to work when connected to an Automation controller like the IntelliTouch, EasyTouch, or SunTouch, those units must be configured with the IntelliChlor enabled. The displays is as follows: -------------------------------------Chlorinator Info: Salt: 4500 ppm Status Code=00H [OK-NO ERRORS ] V -------------------------------------To get updated ppm, cycle SCG power and wait. Press any button -------------------------------------Possible messages are: No Flow Low Salt Very Low Salt High Current Clean Cell Low Voltage Cold Water INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 22 Configuration Menu (Continued) Status Codes: This displays a complex series of values that indicate the real-time status and alarm conditions. Top line, Codes: HA= is the automation Home Address that IntelliChem has locked onto. In the upper-right corner, R0,1,2,4 which represents the UOC comm status. R0 = standalone (no KA from Automation since power up) R1 = Found KA packets within 30 seconds of power up R2 = Found KA packets later, after 30 seconds, so was operating in standalone for a while R4= Was in Automation mode (sending IntelliChlor commands through IntelliTouch) but has dropped the connection. The two-digit number (0-99) directly below the R# is the number of seconds it’s gone without a valid KA packet. It should generally be 00-04 seconds. More than that means that IntelliChem is missing the automation KA packets. Note: Status and Alarm hexadecimal displayed codes represent the current IntelliChem status. For further information, contact Technical Support (800) 831-7133. Factory Reset: Clear all calibrated values and run Auto Setup to initialize IntelliChem. For Factory Default Settings. Self Test Sequence: Upon entering a self test sequence, all dosing will pause until the test is completed. Follow the on-screen prompts. “PASSED” indicates the test was successful. See Troubleshooting section for error conditions, on page 46. Hardware Most common hardware configurations can be selected by using the Auto Setup Wizard. This menu allow more complex and custom settings.Use the Hardware menu to configure IntelliChem for the pH and ORP hardware controls and dose being used. Upon entering the hardware setup menu, all dosing will pause until the hardware setup is completed. After pressing the Hardware button the following message is displayed. Dosing will resume when you _exit this menu_ Press any button To access the hardware menu: Press MENU Configuration Hardware pH Control (page 1/2 - 2/2) Doser Type 1/2: Select the pH Control Dose Type: - IntelliChem pH feed method being used (INTERNAL PUMP, EXTERNAL RELAY, CO2 EXT/RELAY (Carbon dioxide tanks), NONE. Doser Type 2/2: - INTERNAL PUMP: Right, MTR_R, Left, MTR_L - EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2 - CO2 EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2 Flow (Rate) 2/2: - INTERNAL PUMP (MTR_R/MTR_L): FLOW: xxx GPD (gallons per day) (53, 65, 75). - EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set to 0 to use time-based feed instead of volumetric (only on the Ext Relays (not internal motors). - CO2 EXTERNAL RELAY 1 or 2: Use Time (0) or SCFH (1-400). INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 23 Configuration Menu (Continued) ORP Control (page 1/2 - 2/2) Doser Type 1/2: Select the ORP control hardware: - IntelliChem ORP feed method being used (INTERNAL PUMP, EXTERNAL RELAY, INTELLICHLOR® Salt Chlorine Generator (SCG), NONE. Doser Type 2/2: - INTERNAL PUMP: Right-Side (MTR_R), Left-Side (MTR_L) - EXTERNAL RELAY: Ex_Relay 1, Ex_Relay 2 - INTELLICHLOR: All Models (IC20, IC40, IC60) Flow (Rate) 2/2: - - INTERNAL PUMP (MTR_R/MTR_L): FLOW: xxx GPD (gallons per day) EXTERNAL RELAY 1 or 2: RATE: xxx GPD (gallons per day). Note: Set to 0 to use time-based feed instead of volumetric (only on the Ext Relays (not internal motors). Hardware settings must be chosen carefully. If both dosers are assigned to the same internal pump or external relay, the program will display an error message upon exiting the Hardware menu. Alarm Output Select the following the IntelliChem® Controller alarm output information: - External alarm output: Ex_Relay1 or Ex_Relay2. For an external alarm indicator, an unused relay may be selected to turn on when the red Alarm LED on the front panel is turned on. The alarm relay must be chosen carefully. If Ex_Relay1 or Ex_Relay2 is used for a doser, it must not be used for an alarm output. Upon exiting the Hardware menu, the program will check to be sure the same relay is not used more than once. If a relay is assigned to more than one function, an error message will be displayed. error message: ------------------------- Alarm Relay conflicts with Ext Doser Relay Changed to Ex_R1 -------------------------- or Changed to Ex_R2 or Changed to N/A INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 24 Auto Setup Auto Setup See page 6 for details. Sat Index Saturation Index The Saturation Index (SI), also called the Langelier Index, is a chemical equation or formula used to diagnose the water balance in the pool. The Saturation Index formula is SI = pH + TF + CF + AF - 12.1 (or 12.2 for salt pools). To calculate the Saturation Index, you must first test the pool water for pH, temperature, calcium hardness, and total alkalinity. Refer to a chart for assigned values for your temperature, hardness, and alkalinity readings then add these to your pH value. Subtract 12.1 (or 12.2 for salt pools), which is the constant value assigned to Total Dissolved Solids and a resultant number will be produced. A result between +/-0.3 indicates balanced water. Test results not within these values require chemical adjustments to achieve balance. This formula is more or less reliable but not guaranteed. In some cases, individual readings for pH, calcium, and Total-Alkalinity might be beyond normal recommendations, however, combined within the formula can produce “balanced water.” The SI is useful to pinpoint potential water balance problems. To access the Sat Index menu: Press MENU / Saturatn Index Press / and /to adjust the Saturation Index values. Menu ORP Menu Saturatn Index Configuration pH pH: 6.0 77F CH: 250 TA: 90 Temp: SLT1000 CYA:18 Sat Index Menu Note: The pH, Temp, and SLT are entered automatically as the numbers are available from the measurement and automation system. Each time this display is entered, if available, the current temperature is obtained from the INTELLITOUCH®, EASYTOUCH® Control System), SLT is obtained from the INTELLICHLOR® Salt Chlorine Generator (SCG). But these values can be changed on this screen for calculation purposes. pH: Enter the current pH value. Temperature: Enter the current temperature setting. CH: Enter the current calcium hardness level. SLT: Enter the current salt level or Total Dissolved Solids (TDS) level if no SCG is used. TA: Enter the current total alkalinity value. CYA: Enter the current cyanuric acid value. SI: Displays the last calculated SI value (Corrosive/Scaling/Ideal). Note: If there is no flow or Flow Delay is enabled, no SI value displayed. pH: 6.0 77F CH: 250 TA: 90 Temp: SLT1000 CYA:18 pH: 6.0 77F CH: 250 TA: 90 Temp: SLT1000 CYA:18 INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 25 Sat Index (Continued) Recommended Pool Chemistry pH range: 7.2 to 7.6 ORP range: 650 to 750 Alkanlinity: 80 to 120 ppm Calcium Hardness: 200 - 500 ppm Cyanuric Acid/Stablizer: 30-50 ppm pH: Chlorine produced by the IntelliChlor SCG is close to Neutral pH. However, other factors usually cause the pH of the pool water to rise. Therefore, the pH in a pool chlorinated by IntelliChlor tends to stabilize at approximately 7.8. This is within APSP standards. If the pool pH rises above 7.8, have a pool professional test to see if other factors such as high Calcium Hardness or Total Alkalinity are the cause and then balance accordingly. Temperature: The pool water temperature can affect the saturation index value. IntelliChem gets the temperature from the EasyTouch, IntelliTouch and SunTouch automation control system. The automation control system must have the POOL or SPA pump running to report the proper temperature to IntelliChem, otherwise IntelliChem will use its own menu’s temperature value. To change the IntelliChem default temperature, select Temp and use the Up/Down arrow to adjust the temperature. pH Level Test: Test the pH level of your pool water with a reliable test method. If necessary, adjust according to your pool professional’s recommendations. APSP’s recommended ideal range for pH is 7.2 to 7.6. Note: Never use dry acid (sodium bisulfate) to adjust pH in arid geographic areas with excessive evaporation and minimal dilution of pool water with fresh water. A buildup of by-products can damage the IntelliChlor SCG Calcium Hardness Recommended range for calcium hardness is 200-500 ppm. Calcium Hardness levels should be tested weekly. Calcium hardness is the calcium carbonate scale deposited on pool surfaces. The test for Calcium Hardness is a measure of how “hard” or “soft” the water is testing. “Hard” water can have high levels of calcium and magnesium. If these levels are too high the water becomes saturated and will leave calcium carbonate scale deposits (a “white-ish,” crystallized rough spot) on any surface inside the pool. If the levels are too low, the water becomes “soft” and will corrode surfaces inside the pool. Use TSP or Hydroquest 100 to lower Calcium Hardness levels that are too high or add water to the pool which has a lower calcium hardness content. Levels which are too low require the addition of calcium chloride. Total Dissolved Solids (TDS): Adding salt to pool water will raise the TDS level. While this does not adversely affect the pool water chemistry or clarity, the pool water professional testing for TDS must be made aware salt has been added to the IntelliChlor system. The individual performing the TDS test may then subtract the salinity level to arrive at a TDS level that would be compatible to a TDS reading for a non-salt water pool. Note: If a salt chlorine generator is being used for your pool, the salt level is the TDS level of the pool. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 26 Sat Index (Continued) Total Alkalinity APSP’s recommended ideal range for total alkalinity is 80 to 120 ppm for “gunite” and concrete pools and 125-170 ppm for painted, vinyl, and fiberglass pools. Test levels weekly and adjust according to your pool professional’s recommendations. Total Alkalinity can be described as a buffer that keeps pH in order. pH depends on the ability of the total alkalinity in the water to withstand the changes in pH. If the total alkalinity is too high, adding acid (similar to pH) lowers the level. Adding a base (e.g sodium bicarbonate) when total alkalinity is low, raises the level. The level of total alkalinity in the water is a measurement of all carbonates, bicarbonates, hydroxides, and other alkaline substances found in the pool water. Cyanuric Acid: Cyanuric acid is needed in outdoor pools to help to stabilize and maintain proper levels of chlorine. 90% of unstabilized chlorine is destroyed by the UV radiation from the sun. Cyanuric acid stabilizes chlorine in water from UV degradation. When using the IntelliChlor SCG, the cyanuric acid level should be maintained between 30-50 ppm. Optimum Pool Water Chemistry Conditions for Salt Water Pools (using the IntelliChlor® Salt Chlorine Generator (SCG) In accordance with the Association of Pool and Spa Professionals (APSP) standards, it is recommended that the pool water chemistry conditions (see page 21) be maintained on an on going basis to help protect pool users, pool related equipment and surfaces in and around the pool. These values are important to maintaining the pool equipment in proper operating condition and preventing corrosion, liming or other problems. The IntelliChlor (SCG) is warranted to operate properly only if these conditions are met. For more information, refer to your local agency having jurisdiction, NSPI (National Spa and Pool Institute), the CDC (Centers for Disease Control), or the WHO (World Health Organization). Recommended pool water chemistry is given below: Free Chlorine: 2.0 - 4.0 ppm. Above 4.0 ppm may cause corrosion of metal components Combined Chlorine (Chloramines): None (super chlorinate to remove all chloramines) pH: 7.2 - 7.8 (USE MURIATIC ACID to lower pH and Soda Ash to raise pH.) Cyanuric Acid: 30 - 50 ppm Total Alkalinity: 80 - 120 ppm Calcium Hardness: 200 - 400 ppm TDS (includes salt): 3000 minium to 5700 to 6000 maximum ppm Salt: 3000 - 4500 ppm (ideal 3400 ppm) Metals (Copper, Iron, Manganese): None Nitrates: None - Phosphates: Less than 125 ppb Using the Langelier Saturation Index (LSI) to Diagnose Water Balance Use the Langelier Saturation Index (LSI) calculator to diagnose the water balance in your pool. Water with a LSI of 1.0 is one unit above a balanced condition. Reducing the factors by 1 unit will bring the water into equilibrium. To use the LSI calculator, refer to: http://www.pentairpool.com/pool-owner/resources/calculators/langelier/ INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 27 Sat Index (Continued) Calculating the Saturation Index The saturation index is a formula that relates pH, calcium and alkalinity in the pool water. A well balanced pool water will have a formula result range between -0.5 and 0.5 Outside this range, the pool water is out of balance, potentially damaging pool equipment or scaling the salt chlorine generator. The equation to calculate Si is: SI = pH + CHF + AF + TF - TDSF Saturation pH as tested Index Calcium Alkalinity Hardness Factor Factor Temperature TDS Factor Factor (12.1 non-salt, 12.2 salt pools) Cyanuric acid in the form of cyanurate ions contribute to alkalinity. Thus, a correction must be made to total alkalinity. We subtract 1/3 of the cyanuric acid level from the reading obtained in the total alkalinity test. Total Alkalinity - 1/3 Cyanuric Acid = Corrected Alkalinity This correction can be considerable in established pools with high cyanuric acid levels; for example, at 240 ppm cyanuric acid, the correction amounts to 80 ppm (240 ÷ 3 = 80). Saturation Index Tables (as recommended by NSPF) INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 28 INSTALLATION (INTELLICHEM® CONTROLLER AND FLOW CELL) Installing the IntelliChem® Controller Before installing the IntelliChem controller, read the following instructions. 1. IMPORTANT! If the equipment pad is below the water level of the pool, please install a CHECK VALVE after the heater or use a Hartford Loop. 2. Identify new and existing equipment to be connected. 3. Decide if the sensors will be in a separate bypass line, or if the Flow cell will be used. Caution: If the Flow Cell is being installed, the input water maximum pressure is 25 PSI. 4. Determine the supply voltage, 110 VAC or 220 VAC, and wire the transformer wires as needed (see page 30). 5. Determine if the control to the equipment uses the same voltage as the supply voltage. All controlled equipment must be compatible. 6. Determine the water-tap points for the flow cell bypass inlet and outlet. 7. Install the Flow Cell away from direct sunlight and on a flat vertical surface. 8. Switch the main house circuit breaker OFF. Connect the supply voltage to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/ power center (see page 40 for the IntelliChem controller AC power wiring diagram). This ensures that the IntelliChem controller will only dispense chemicals when the filter pump is ON. Note: The IntelliChem controller must be connected to a separate dedicated circuit GFCI. 9. If using a Flow Cell install the bypass now. 10. Connect the pH and ORP sensors. 11. Test the plumbing for leaks. 12. Switch on the IntelliChem controller for the first time as described below. Risk of Electrical Shock or Electrocution! IntelliChem controller must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the current National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. Always disconnect the power to the IntelliChem controller enclosure at the circuit breaker before servicing the unit. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock. !Warning: A means for disconnection(i.e. all pole) must be incorporated in the fixed wiring in accordance with the wiring rules and conducted by qualified electrician. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 29 Mounting IntelliChem® Controller Enclosure Mount the IntelliChem controller enclosure as follows: 1. Select a location for mounting the IntelliChem® Controller enclosure with the following required recommendations: 2. Install the IntelliChem controller enclosure at least 10 feet from the pool or spa wall. 3. Supply power must be routed to the IntelliChem controller in accordance with the applicable national and current local (NEC) codes (see page i). 4. The installation surface must be solid and vertical. Do not mount the IntelliChem controller enclosure in a horizontal position. 5. Maintain adequate clearance for opening the enclosure. 6. The environment should be free of chemical fumes and excessive heat. The maximum temperature it should not exceed is 110 ºF (50 C). 7. Mount as far as possible from sources of electrical interference. 8. Mount the enclosure on a flat surface. 9. Hold the enclosure against the mounting surface with a closed lid and mark the location of the mounting brackets located on the sides of the enclosure next to the wall. Prepare holes as necessary and secure enclosure using the provided mounting screws. 10. Install a conduit into the controller enclosure. Locate the chemical feed pumps and the chemical storage tanks in a safe and secure area. Never turn the chemical feed pumps on when both flow cell valves are closed. Increased pressure may cause the feed lines to blow off and spray full strength chemicals on anyone or anything near the equipment. Securely fasten all electrical, water, and chemical lines. Alarm MOUNTING HOLES Menu Select MOUNTING HOLES INTELLICHEM WATER CHEMISTRY ® INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 30 Wiring the IntelliChem® Controller Transformer for 120 VAC or 240 VAC DANGER! RISK OF ELECTRICAL SHOCK OR ELECTROCUTION Always disconnect AC power to IntelliChem controller at the circuit breaker before servicing. Failure to do so could result in death or serious injury to installer, serviceman, pool users, or others due to electrical shock. HIGH VOLTAGE WIRING The high voltage wiring compartment is located inside the IntelliChem controller enclosure. The IntelliChem controller can be connected either to 120 VAC or 240 VAC. The IntelliChem controller should be wired to receive power from the filter pump relay. The maximum current rating is 200/100 mA at 120/240 VAC (60 or 50 Hz). Connect the AC power supply voltage to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for the IntelliChem controller AC power wiring diagram). There is no ground/bonding terminal required at this non-metallic enclosure. Follow manufactures instructions when installing and testing of ground fault circuit breakers (GFCB) and interrupters (GFCI). IntelliChem® Controller Circuit Board RED RED/WHITE WHITE BLUE BLACK BROWN Connect input AC wires to the IntelliChem controller transformer wires as follows: • 120 VAC: Connect one 120 VAC source wire to the Brown/Black wires connected together and one wire to the Blue/White wires connected together. • 240 VAC: Connect one 240 VAC source wire to White wire and one wire to Brown wire. The Black/Blue wires are connected together. WHITE BLUE BLACK BROWN 240 VAC EX_RELAY 2 EX_RELAY 1 120 VAC INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 31 Connecting External Devices to IntelliChem External Devices such as pumps, CO2 devices and alarms can be connected to either of the dry contact relays (EX_RELAY 1 and EX_RELAY 2). Relay contact ratings: 5 AMPS, 250VAC/30VDC located on the IntelliChem® Controller circuit board. See wiring diagram below and “Plumbing Installation” on page 37. BE SURE TO DISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING THE INTELLICHEM® CONTROLLER. AC Power may be supplied to the relay terminals Ex_Relay1 and Ex_Relay2 from other sources. 240 VAC 120 VAC IntelliChem® Controller RED RED/WHITE WHITE BLUE BLACK BROWN WHITE BLACK BLUE BROWN Wiring external devices must be performed by a licensed certified electrician or a qualified pool professional in accordance with the current National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to property. EX_RELAY 1 EX_RELAY 2 EXTERNAL DEVICES Alarms and external pumps option: 1 pump (acid feed) 2 pump (acid/chlorine feed) Chlorine Pump Acid Pump LINE EXTERNAL DEVICE NEUTRAL GROUND + EXTERNAL DEVICE CO2 Tank CO2 Kit P/N714000070 EXTERNAL DEVICE (IntellilChlor® Salt Chlorine Generator (Commercial model only) L_Pump EX_IC (See Auto Setup on page 7) - External Devices: EX_RELAY 1 and EX_RELAY 2, contact ratings: 5 AMPS, 250 VAC/30 VDC 120 VAC SUPPLY VDC LOW VOLTAGE SUPPLY Dry contact connection External Device Wiring Diagram INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 32 Installing the Flow Cell and pH/ORP Sensors (Kit Contents) pH and ORP sensors are shipped with a protective cap covering the electrode tip of the probes to protect the sensing element. DO NOT MIX THESE CAPS - Solutions will destroy the other type of probe. Sensors should be kept in the protective cap until ready for installation, if the sponge in the boot becomes dry, wet it with pool water. Before using the sensor remove the cap. IntelliChem® Controller Kit Contents 18 15 17 14 7 16 1 19 2 3 6 7 4 13 5 20 21 8 9 10 11 Item # Qty. Part # Description INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 33 Mounting the Flow Cell Remove Flow Cell from shipping carton and select a suitable location for the flow cell within two (2) feet of the IntelliChem® Controller. Note: The 3/8” flexible tubing that is required to connect the flow cell to the rest of the system is included with IntelliChem controller kit. Mounting holes Flow Switch Magnet Flanged end down Installing the pH and ORP Sensors (Read This First) Install the pH and ORP sensors as follows: For IntelliChem® Controller Plumbing Installation Diagram, see page 37. 1. Sensors wires will connect to within 10 feet. 2. Water leaks will cause damage! Mount where water does not leak and damage other components. 3. Mount flow cell vertically with provided screws. 4. Securely fasten all electrical, water and chemical lines. 5. Locate chemical feed pumps and chemical storage tanks in a safe and secure area. 6. Maximum operating pressure = 25 psi. 7. Extreme pressure variances may affect readings and can cause damage to the sensors. 8. Avoid installing the outlet before the main pump as the vacuum may damage the chemical sensors. 9. Only inject chemicals on the outlet side of the IntelliChem controller Flow Cell INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 34 Installing the pH and ORP Sensors To install the Flow Cell pH and ORP sensors: 1. Keep pH and ORP sensors wet at all times, install the sensors into the flow cell. Hand-tighten only and save caps for future use (DO NOT MIX THESE CAPS), fill flow cell with water. The sensors have O-Rings and don’t require threaded sealing tape. • Do not rub hard on the glass element in the sensor or use sand paper or other polishing material to clean. • Handle electrode carefully. • Sensors contain external and internal glass elements. • Do not drop or otherwise subject the sensor to vibration, physical impact. To avoid permenant damage of sensors or flow cell, do not use during freezing conditions. • Leave excess wire outside the controller enclosure. If the cable is longer than needed, it should be coiled neatly and attached under the controller enclosure. • DO NOT CUT THE SENSOR WIRES. Do not stuff excess wire inside the controller as this may cause excess strain on sensor and relay connections. pH Sensor ORP Sensor INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 35 Plumbing the Flow Cell Be sure to have a licensed plumber perform all plumbing; this is important, as they will be familiar with all of the codes in the local area. To connect the Flow Cell to the system plumbing: See page 37 for plumbing diagram. 1. At the equipment pad, switch off the filter pump and release the pressure from the system by opening the valve on top of the filter. WARNING CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the house before drilling into any pipes. Securely fasten all electrical, water and chemical lines. Locate chemical feed pumps and chemical storage tanks in a safe and secure area. 2. Close all valves to prevent flooding. 3. Attach the IN and OUT tubes to the Flow Cell Inlet and Outlet (see Tubing Installation Diagram shown below). 4. Run the end of the IN tube to the chosen pressure line. Choose a location that provides enough space to drill and to tighten the clamp (must be after the filter, but before the heater). Be sure the tube is not pinched or kinked. Mark a spot on the pipe. 5. Locate where the water will be supplied from and returned for each flow cell. The most common location for the water inlet to the flow cell is AFTER the main filter and BEFORE the heater. See page 37. 6. Drill a 3/8” hole for the flexible tubing fitting on the mark and immediately place the fitting into the pipe. Align pipe clamp with the fitting and tighten the pipe clamp. 7. Run the end of the OUT tube (with the pipe clamp) to the chosen return line. Choose a location that provides enough space to drill and to tighten the clamp (must be after the heater - see page 37). Be sure the tube is not pinched or kinked. Mark a spot on the return line pipe. 8. Drill a 3/8” hole for the flexible tubing fitting on the mark and immediately place the fitting into the pipe. Align pipe clamp with the fitting and tighten the pipe clamp. 9. Open any closed system valves. Close the filter valve and turn on the circulation system. Check that the system is working properly. Tubing Pipe Clamp 3/8" Drill Pipe IntelliChem® Controller Tubing Installation Diagram INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 36 Plumbing the Flow Cell (Continued) Do not inject acid directly in to the flow cell. Injecting acid in this way will result in incorrect reading which may damage the existing pool equipment. 10. Locate the chemical injection points. 11. Prepare and install the chemical injector fittings. 12. Install the chemical storage containers. 13. Turn ON the main circulation pump. 14. Check for leaks and verify the flow sensor indicates flow. Flow Cell Inlet and Exit Lines 1. It is essential that the supply line be at a higher pressure than the discharge line so the water will flow through the cell at a steady rate in the right direction. 2. Inlet should be installed after filter and before heater. Note: Plumb the INLET before the solar valve. 3. Exit should be installed after heater and as far away from any equipment as possible. Make sure all pumps are OFF before drilling into pipes. Never switch ON chemical feed pumps without the pool filter pump also running. The flow switch is a dry contact only (no current). Use with any other brand of flow switch voids WARRANTY and UL listing. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide Tubing Fitting Check Valve Outlet FILTER Inlet ® INTELLICHEM WATER CHEMISTRY HEATER CHLORINE P/N 521895 (see page 32) ACID Chlorine Pump Figure 2: IntelliChem® Controller Plumbing Installation HAND TIGHTEN FITTINGS ONLY: USING A WRENCH TO TIGHTEN WILL CRACK FITTINGS Sample Valve Flow Cell Acid Injection pump IntelliChem Acid Pump Water Flow CO2 Kit P/N714000070 CO2 Tank Chlorine Pump External pumps option: 1 pump (acid feed) 2 pump (acid/chlorine feed) 37 IntelliChem® Controller Installation Plumbing Diagram INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 38 Connecting the Sensors Wires to IntelliChem® Controller Circuit Board The Flow Switch is a Dry Contact Only (No Current). This Flow Switch should only be used with the IntelliChem® Controller. Use of this Flow Switch with any other brand of controller will void the warranty and UL listing. 1. Route the Flow Cell switch wires into the IntelliChem controller enclosure through the strain relief and connect the wires to J6 Sensor terminal connector on the IntelliChem controller circuit board. Connect the BLACK wire to the GND screw terminal and the RED wire to the FLOW screw terminal. 2. Route the pH and ORP sensor wires into the IntelliChem controller enclosure through the strain relief and connect to J6 Sensor terminal connector on the IntelliChem controller circuit board. The sensor wires are labeled. PLUS AND MINUS POLARITY MUST BE OBSERVED. pH sensor wire: Connect the GREEN to the pH - screw terminal and the CLEAR wire to the pH + screw terminal. ORP sensor wire: Connect the GREEN to the ORP - screw terminal and the CLEAR wire to the ORP + screw terminal. IntelliChem® Controller Circuit Board SENSORS ORP PROBE FLOW SWITCH NOT CONNECTED BLK GRN YEL RED CLR GRN CLR GRN RED BLK pH PROBE COM Port J7 pH + pH ORP+ ORPFLOW GND J6 EX_RELAY 2 EX_RELAY 1 DRY CONTACTS TO EXTERNAL DEVICES (Connect wires in front - See Manual for details) OPEN + DATA - DATA GND To Automation or IntelliChlor Power Center COM Port Figure 2: IntelliChem® Controller J6/J7 Circuit Board Wiring 3. Turn the main pump on and open the valves to test for leaks and the free movement of magnet. Magnet must be all the way up in order to close the flow switch. 1/4 GPM will push the magnet all the way up. Make sure that all pumps are off before drilling into any pipe. Never turn chemical feed pumps on when either flow cell valve is closed. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 39 CONNECTING TO AN AUTOMATION CONTROL SYSTEM Wiring IntelliChem® Controller AC Power to Filter Pump Relay IntelliChem AC Power Wiring Instructions: When using IntelliChem as a stand alone device (with a time clock) or with an IntelliChlor salt chlorine generator, IntelliChem MUST BE CONNECTED TO THE PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for IntelliChem AC power wiring diagram). This ensures that IntelliChem will only dispense chemicals when the filter pump is ON. For IntelliTouch®, EasyTouch® or SunTouch® control system using an IntelliFlo® pump (or 2-speed pump) and an IntelliChlor® (SCG), the IntelliChlor controller AC power center wires must also be connected to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for diagram). This ensures that IntelliChem controller and IntelliChlor SCG only produce chlorine when the main filter pump is on. The following wiring diagram (see next page) shows the IntelliChem controller AC power wiring and COM port connections to the EasyTouch, IntelliTouch and SunTouch control system. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 40 IntelliChem® Controller AC Power and COM port (RS-485) Wiring Diagram IntelliChem® Controller Circuit Board COM Port J6 J7 LOAD SIDE +12 VDC LOAD SIDE RED YEL IntelliChem Controller AC Power (connects to filter pump relay) + DATA - DATA GND EasyTouch®, IntelliTouch® Control System Load (or Power) Center Circuit Board NOT CONNECTED GRN BLK EX_RELAY 2 EX_RELAY 1 EASYTOUCH, INTELLITOUCH, SUNTOUCH CONTROL SYSTEM LOAD/POWER CENTER PUMP FILTER RELAY TO AUX PLUG (FILTER PUMP) ON CIRCUIT BOARD FILTER PUMP RELAY IN LOAD/POWER CENTER IntelliChlor® SCG Power Center (wired for 120 or 240 VAC) LOAD SIDE LOAD SIDE IntelliFlo® Pump (Pool Filter Pump) LOAD SIDE COMMUNICATION CABLE LINE SIDE:Source voltage -120 VAC or 240 VAC to circuit breaker sub-panel 2-SPEED PUMP OPTION TO AUX SOCKET (FILTER PUMP) ON CIRCUIT BOARD TO AUX SOCKET ON CIRCUIT BOARD IntelliChlor® Salt Chlorine Generator Communication Cable Note: For more information about operating automation pool controllers, refer to the following manuals: - IntelliTouch® Control System User’s Guide (P/N 521075) - EasyTouch® Control System User’s Guide (P/N 521044) 2-SPD Pump (wired for 120 or 240 VAC) INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 41 CONNECTING TO AN AUTOMATION CONTROL SYSTEM Wiring IntelliChem® Controller AC Power to Filter Pump Relay IntelliChem controller AC Power Wiring Instructions: When using the IntelliChem controller as a stand alone device (with a time clock) or with an IntelliChlor salt chlorine generator, IntelliChem controller MUST BE CONNECTED TO THE PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for the IntelliChem controller AC power wiring diagram). This ensures that the IntelliChem controller will only dispense chemicals when the filter pump is ON. Note: For IntelliTouch®, EasyTouch® or SunTouch® control system using an IntelliFlo® Pump (or 2-speed pump) and an IntelliChlor (SCG), the IntelliChlor controller AC power center wires must also be connected to the PUMP SIDE OF THE MAIN FILTER PUMP RELAY located in the load/power center (see page 40 for diagram). This ensures that the IntelliChem controller and IntelliChlor SCG only produce chlorine when the main filter pump is on. To connect IntelliChem controller AC power wires to EasyTouch, IntelliTouch and SunTouch control system filter pump relay (see diagram on previous page). DANGER! RISK OF ELECTRICAL SHOCK OR ELECTROCUTION Always disconnect AC power to EasyTouch, IntelliTouch and SunTouch control system load/power center at the circuit breaker before servicing, or removing the HIGH VOLTAGE FRONT PANEL. Failure to do so could result in death or serious injury to 1. IntelliChem Controller AC power: Run the IntelliChem controller AC power wires to the EasyTouch, IntelliTouch or SunTouch control system enclosure. 2. EasyTouch or IntelliTouch Control System Load Center: Unlatch the enclosure door spring latch, and open the door. 3. Discharge Electrostatic energy before removing the cover by first touching the metal part of the enclosure. 4. Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT PANEL. Remove the panel from the enclosure. 5. Connect the IntelliChem controller AC power cord wires to the LOAD/ PUMP SIDE of the main filter pump relay (see wiring diagram on page 40). 6. When the connection is completed: EasyTouch and IntelliTouch Control System: Close the control panel and secure it with the two (2) retaining screws. SunTouch Control System: Close the front control panel and secure with the retaining screw. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 42 Retaining screws High Voltage Front Panel Route IntelliChem® Controller AC power into opening under enclosure CONNECT INTELLICHEM CONTROLLER AC POWER TO FILTER PUMP RELAY CONNECT INTELLICHEM CONTROLLER AC POWER TO FILTER PUMP RELAY Power Center (with SCG option) Load Center (with SCG option) IntelliChlor® Salt Chlorine Generator(SCG) Transformer INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 43 Connecting IntelliChem® Controller RS-485 Communication Cable to the Control System Circuit Board To connect the IntelliChem controller COM Port Cable to EasyTouch®, IntelliTouch® and SunTouch® Control System COM port (see page 40): 1. IntelliChem controller RS-485 cable: Strip back the cable conductors ¼ in. Insert the wires into the connector screw terminals. Make sure to match the color coding of the wires; YELLOW = +DATA, GREEN = -DATA and BLACK = GND. (Red wire is not connected). Secure the wires with the screws. 2. Run an RS-485 cable from the IntelliChem controller enclosure to the EasyTouch, IntelliTouch or SunTouch control systems enclosure. 3. Unlatch the load center/power center enclosure door spring latch, and open the door. 4. WARNING! Switch AC power OFF to load/power center before installation (see note on page 41) EasyTouch or IntelliTouch control system load center: Loosen the two (2) retaining screws from the control panel. (a) Lower down the control panel on its hinges to access the motherboard located behind the control panel. (b) Route the IntelliChem controller RS-485 cable up through the low voltage raceway in the load center to the motherboard. SunTouch Control System Power Center: Route the conductor cable up through the lower grommet opening into the enclosure. 5. Strip back the IntelliChem controller cable conductors ¼ in. Insert the wires into the COM port connector screw terminals on the circuit board: (EasyTouch J20, IntelliTouch J7/8, SunTouch J11). Make sure to match the color coding of the wires; YELLOW = +DATA, GREEN = -DATA and BLACK = GND. (Red wire is not connected). Secure the wires with the screws. 6. When the connection is completed: EasyTouch and IntelliTouch Contol System: Close the control panel and secure it with the two (2) retaining screws. SunTouch Control System: Close the front control panel and secure with the retaining screw. Setting Up IntelliTouch, EasyTouch & SunTouch Control System IntelliTouch Control System The following describes how to setup the IntelliChem controller from the IntelliTouch control system control panel. From the IntelliTouch control system control panel you can adjust the pH and ORP set point values, view the IntelliChem controller status and monitor your pool water condition using the Saturation Index. To access the IntelliChem controller the screens, from the IntelliTouch control system indoor control panel or the wireless MobileTouch® Controller control panel: Getting There MENU SETUP EQUIPMENT INTELLICHEM PH/ORP Values: The pH and ORP values are displayed next to the set point settings. pH Set: Displays the current pH set point value. The adjustable range is from 7.2 to 7.6 in increments of 0.1. The default pH set point value is 7.5. To adjust the pH set point, press the button next to pH Set. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 44 ORP Set: Displays the current ORP set point value. The adjustable range is from 650 to 800 in increments of 10. The default ORP set point value is 700. The ORP set point is the value that IntelliChem will try to achieve based on the active sanitizer. To adjust the ORP set point, press the button next to ORP Set. STATUS: Displays the current communication link between IntelliTouch and IntelliChem via the RS485 cable. IChem Comm Error: Check the RS-485 communication cable is connected to the COM port on the IntelliTouch Personality circuit board. USING SCG: “USING SCG” displays if the IntelliChlor salt chlorine generator is enabled. The SCG is enabled and disabled from the MENU > SETUP > EQUIPMENT > CHLORINATOR screen. Note: IntelliChem must also be set up to use the IntelliChlor SCG either with the AUTO SETUP Setup Wizard (page 6) or the Configuration/ Hardware/ORP Control/Doser Type (page 23). DISABLE/ENABLE INTELLICHEM: To disable IntelliChem, press the button under DISABLE ICHEM. To enable IntelliChem, press the button next to INTELLICHEM. On the next screen press button next to NO and select YES. Press SAVE to save the setting and return to the Equipment screen. Saturation Index/Menu: To access the Saturation Index screen, press the button next to SATURATION INDEX/MENU. The current Saturation Index value, water condition, water temperature and salt level are displayed. Press the button next the following selections to adjust the levels/values: Calcium Hardness: Recommended range is 200-400 ppm. Levels should be tested weekly. Cyanuric Acid: Stabilizes chlorine in water from UV degradation. When using the IntelliChlor SCG, cyanuric acid level should be maintained between 30-50 ppm. Total Alkalinity: APSP’s recommended ideal range for is 80 to 120 ppm for “gunite” and concrete pools and 125-170 ppm for painted, vinyl, and fiberglass pools. Test levels weekly and adjust according to your pool professional’s recommendations. Saturation Index: The saturation Index displays IDEAL (Optimum levels), CORROSIVE or SCALING. The following are recommended pool chemistry Saturation Index levels: pH range: 7.2 to 7.6 ORP range: 650 to 800. Alkanlinity: 80 to 120 ppm. Calcium Hardness: 200 - 500 ppm. Cyanuric Acid/Stabilizer: 30-50 ppm. Note: See page 27 for information the online Langelier Saturation Index (LSI) Calculator to diagnose the water balance in your pool. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 45 Setting Up IntelliChem® Controller with EasyTouch Control System EasyTouch® Control System The following describes how to setup the IntelliChem® Controller from the EasyTouch Control Systems control panel. From the EasyTouch control system control panel you can adjust the pH and ORP set point values, view the IntelliChem controller status and monitor your pool water condition using the Saturation Index. To access the IntelliChem screens, from the EasyTouch Indoor Control Panel or the EasyTouch wireless control panel: Press MENU > SETTINGS > INTELLICHEM PH/ORP Values: Press the Right button to access the Clock pH and ORP set point values screen. The pH and ORP IntelliFlo sensor reading VALues are shown only if adequate flow is IntelliChlor IntelliChem sensed by the flow switch and the delay has been satisfied. otherwise displays NA (not available) Use the Up/Down IntelliChem button to adjust the pH set point value. Press the Right PH/ORP Values button again to set the ORP set point value. Press MENU Status to save and return to the previous screen. Sat Index pH Set Point: Displays the current pH set point value. The pH VAL 7.0 adjustable range is from 7.2 to 7.6 in increments of 0.1. The pH SET: 7.5 default pH set point value is 7.5. ORP VAL: 650 ORP Set Point: Displays the current ORP set point ORP SET: 750 value. Use the Up/Down button to adjust the ORP set IntelliChem point value. The adjustable range is from 650 to 800 in PH/ORP Values increments of 10. The default ORP set point value is 700 Status The ORP set point is the value that IntelliChem will try to Sat Index achieve. pHLvl: STATUS: Displays the current communication link between ORP Lvl: SCG EasyTouch and IntelliChem via the RS-485 cable. IChem IntelliChem: ON Comm Error: Check the RS-485 cable is connected to the ORP Dosage Limit COM port on the EasyTouch circuit board. If “IntelliChem: --Disabled--” is displayed enabled IntelliChem from the IntelliChem PH/ORP Values automation system (see “Using SCG” on page 44). Other Status alarm messages are shown on page 48 Sat Index pH: 7.5 TMP: 91 CH: 250 SLT: 4250 TA: 100 CYA: 30 SI= +0.04 IDEAL Level Gauge indicator: Press the Up/Down button to “fill” the gauge icon so that it visually represents the same amount of acid available in the container. Press Up/Down button six (6) times to fill the gauge (three times to half fill the gauge). Six horizontal bars represent chlorine (or bromine) supply is full. One bar indicates the supply is nearly empty. Press MENU twice to exit and update the values. Note: IntelliChem must also be set up to use the IntelliChlor SCG either with the AUTO SETUP Wizard (page 6) or the Configuration/Hardware/ORP Control/Doser Type (page 23). Sat Index: To access the Sat Index settings, press the Up/Down button then press the Right button. Use the Up/Down button to adjust the levels/values for: CH (calcium hardness), SLT (Salt Content in water or Total Dissolved Solids if no salt is present), TA (total alkalinity), CYA (cyanuric acid) and TMP (current temperature). Note: See table below for ideal Saturation Index levels. SI: The saturation Index is displayed. IDEAL: Optimum levels. CORROSIVE or SCALING: Press the Menu button twicw to exit and update the values. Return to this menu for updated SI calculations. screen. Note: See page 24 for information the online Langelier Saturation Index (LSI) Calculator to diagnose the water balance in your pool. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 46 Setting up IntelliChem® Controller with SunTouch Control System SunTouch Automation Control System The following describes how to view the current IntelliChem pH and ORP levels from the SunTouch control panel. To access the IntelliChem screens Press MENU > DIAGNOSTICS > INTELLICHEM Displays the current pH and ORP levels. The IntelliChem IntelliChem controller is connected to the SunTouch control system pH: 7.65 ORP:832 via the RS-485 cable. The RS-485 communication cable is connected to the COM port on the SunTouch® Control System circuit board. TROUBLESHOOTING General Troubleshooting Guide (also see Help Guide on page 47) 1. Run Meter Self-Test (see Configuration menu) 2. 3. 4. 5. 6. Run Probe-Open Test (see Configuration menu) Clear pH and ORP Tweaks (see Configuration menu) Clean Sensors (see Maintenance section) Check chemicals and feed system Take sample of pool water for analysis of CYA, alkalinity, check saturation index, Balance water 7. Replace Sensors 8. Repeat above steps General Guidelines - pH or ORP not able to reach setpoint This may be a common issue that can easily be resolved by increasing the amount of chemical dispensed each day. If the pH Sensitivity is set to “Low” (the default), IntelliChem will only administer the full dose at 0.5 from setpoint. If it seems to be stuck 0.3 from setpoint, you’re only getting 3/5 of the programmed dose. Change the Sensitivity to “High” and you’ll get the full dose at 0.2 pH or greater from setpoint. Or, turn pH Sensitivity OFF only turn it on if you’re overshooting the setpoint. Increasing the dose would essentially do the same thing. Increase the dosage as well as the dose-limit and reduce the mix time so you still get all 8 doses in the filter run time. Diagnostics Self Test and Error codes The overall functionality of the IntelliChem can be verified by running the self test. Access this feature in the Configuration/Diagnostic menu. The test verify the LCD display, front panel LED indicators, push buttons, flow switch input, doser motors, relays, the RS-485 communication, and the meter. Warning! This test will turn on the doser, so be sure that the tubing is installed in a safe manner so that the chemicals will be safely contained. Error Codes 0x01 : LCD 0x02 : Backlight 0x04 : LEDs 0x08 : Buttons 0x10 : Flow Switch 0x20 : Outputs 0x40 : Loopback 485 0x80 : Meter INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 47 Help Guide INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 48 Alarm Messages and Troubleshooting Tips The IntelliChem is continually monitoring its own condition and that of the water chemistry. The following is a list of alarms and most likely causes. This should give you a good starting place for troubleshooting and resolving the alarm. Troubleshooting the alarm messages IntelliChem Message** SI Scaling / SI Corrosive EasyTouch/IntelliTouch, Screen Logic SI Scaling SI Corrosive UOC Comm Err Comlink Lost Communication Lost Auto Calibration …Failed Auto Cal Failed Calibration Failed Invalid EE CRC or Rev# Memory Error SCG Comm Err Salt Chlorine Generator Comm Error Salt Chlorine Generator Communication Error pH/ORP Invald Setup Invalid Setting Invalid Hardware Config pH/ORP Dose Limit pH Dosage Limit ORP Dosage Limit pH Feed at Limit ORP Feed at Limit pH >7.8 Lockout PH Lock Out Sanitizer Feed Locked Troubleshooting Tips Water conditions indicate water has exceeded the threshold level. Refer to Langelier Saturation Index water balance information and the user settings in the Configuration/Preferences 2/2 page Connection between IntelliChem and the automation controller. Check RS485 4-wire connection, terminals, and cables. Check that the printed circuit board is clean and dry. Dirt, condensation or water leaking into the enclosure will cause faulty readings. Turn unit off and on again. If problem persists reload firmware or replace circuit board. The SCG device may not communicate if the water is too cold, not circulating, salt level is too low. It may also take from 2 to 10 minutes or more to begin communication. Sometimes this can be solved by cycling power to the SCG unit and waiting again. Check cable wires and terminals for proper connection. This indicates incompatible settings in the pH setup. Check that the hardware configuration on pH Control page 1/2 and 2/2 correspond properly. That if you specify an internal pump, you’ve chosen one of the MTR_L/R devices, and if you’ve chosen an External doser, you’ve selected an external relay. Be sure you’re not using the same output device for both pH and ORP or an alarm output. Check dosage, and supply settings. Check that if you are dosing by volume that you have provided the GPD of the doser. If you are unable to resolve the problem, re-run the Auto Setup Wizard. When it prompts to use previous values be sure to choose Reset All. This alarm will be the normal course of water chemistry control when experiencing a heavier than expected bather load, high temperature, or improperly balanced water. First check the saturation index and balance the water chemistry. Increase the dosage and filter time, increase the daily limit. During peak loads it may be easiest to administer chemicals by hand. The Limit can be manually cleared in the pH/ORP Settings menu, accessed by the appropriate button to the left side of the LCD display. It can also be programmed to clear automatically each time the IntelliChem powers on, or at every 24 hours of continuous run time in the pH/ORP Dosage 2/2 menu. This is a safety feature that prevents over feeding sanitizer if the pH gets too high. As pH increases, the sanitizer becomes less effective. The proper thing to do is first reduce the pH and then see if you really need to add more sanitizer. Often bringing down the pH is sufficient to free more sanitizer which ** Displayed in various places on the main screen INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 49 Troubleshooting the alarm messages Flashing pH/ORP tank/hourglass symbol Check pH Tank Check ORP Tank ORP LOW ORP HIGH ORP Is Too Low Check overall water chemistry using the Saturation Index calculator or have water tested by a professional pool service person or dealer. Also, check that the dose dispensing device is operating properly and that your supply tank is full. ORP Is To High Overshooting ORP may simply be a result of Cyanuric acid in the pool which suppresses the ORP during the sunlight hours and releases chlorine at night. It may also be that dose size is set too high with insufficient mix time. Turning ORP Sensitivity to “Low” may help reduce overshooting. PH Is Too Low pH Reading Too Low pH HIGH PH Is Too High pH Reading Too High NO FLOW DETECTED Increase filter time and increase dose size. This may be the result of the ORP Sensitivity setting. If the sensitivity is set to “Low”, you may not have a sufficiently sized dose to reach the setpoint. Try turning Sensitivity to “High” or “Off”. ORP Reading Too Low ORP Reading Too High pH LOW Refill the chemical supply container and set the gauge to the appropriate corresponding level. This alarm indicates level is low and should be refilled. If non-fluid supply sources are used, like CO2 and SCG, you can set a reminder in the pH/ORP Supplies 2/2 menu that will trigger this alarm as a reminder to change CO2 canisters or clean the SCG plates. The reminder is reset either in the Supplies 2/2 menu or the pH/ORP Settings button. No Flow Check pump, flow cell, filter, and valves. Overshooting pH may be due to the dose size being set too high with insufficient mix time. Turning pH S ensitivity to “Low” may help reduce overshooting. Test overall water chemistry using the Saturation Index calculator. Low Total Alkalinity may contribute to rapid pH swings and make controlling water nearly impossible. Consult your pool professional. Check overall water chemistry using the Saturation Index calculator or have water tested by a professional pool service person or dealer. Also, check that the dose dispensing device is operating properly and that your supply tank is full. Increase filter time and increase dose size. This may be the result of the pH Sensitivity setting. If the sensitivity is set to “Low”, you may not have a sufficiently sized dose to reach the setpoint. Try turning Sensitivity to “High” or “Off”. Ensure the pool pump is turned on, that valves are properly positioned, and that sufficient water is being directed to the flow cell. Make sure the magnet is properly contained in the flow tube and that the detector is wired properly to the Flow switch terminal block. The flow switch should be closed (shorted) to indicate flow. Warning: This is a Safety Device. Do not operate the IntelliChem with the flow switch bypassed. Water flow must be present to ensure chemicals are mixed adequately to avoid dangerous gasses and high concentrations of chemicals near people or pool equipment. Awaiting FLOW DELAY Flow Delay This is not an alarm, only a message indicating that water chemistry control will commence after this count-down timer expires. To allow pool water to stabilize and time for chemicals to activate, a minimum of 15 minutes is required to get accurate readings. The Flow Delay is set in the Configuration/Delays menu. It is the combination of the Power- On and Flow-Switch delay settings. As a convenience for the pool service person, you may bypass the delay by holding the Up Arrow button for 3 seconds. Please give time for the water to stabilize before expecting proper operation of the equipment. pH has priority PH Priority This is not an alarm but a message that pH is feeding (acid) and that ORP (chlorine) is on hold until the acid feed is finished. This is enabled in the Configuration/Dose Priority menu on systems where the acid and chlorine may be injecting near the same point in the plumbing and the installer has decided, for safety reasons, to only feed one chemical at a time. ** Displayed in various places on the main screen INTELLICHEM® Water Chemistry Controller Installation and User’s Guide SI Corrosive Comlink Lost Auto Cal Failed -.41 Corrosive UOC Comm Err Auto Calib…Failed Invalid Setting ORP Dosage Limit PH Dosage Limit PH Lock Out Check ORP Tank pH/ORP Invald Setup ORP Dose Limit pH Dose Limit pH>7.8 Lockout Flashing ORP tank symbol Flashing pH Tank symbol ORP LOW ORP HIGH pH LOW PH Lockout ORP Chemical Empty PH Chemical Empty ORP Low alarm ORP High alarm PH Low alarm ORP Is Too Low INTELLICHEM® Water Chemistry Controller Installation and User’s Guide pH has priority ** Displayed in various places on the main screen Flow Delay PH Priority Awaiting FLOW DELAY Status “alarm” conditions PH is Too High No Flow pH HIGH No Flow Detected... No Flow Alarm PH is Too Low ORP Is Too High PH High alarm PH Dose Limit ORP Dose Limit Invalid Setup Check PH Tank Memory Error IChlr Comm Error SCG Comm Error Memory Error Invalid EE CRC or Rev# +.53 Scaling EasyTouch/IntelliTouch Message SI Scaling IntelliChem Message** SCG Comm Err Calibration Failed UOC Comm Error Corrosive Scaling IntelliChem Alarm Name PH Priority Flow Delay No Flow pH Reading Too High pH Reading Too Low ORP Reading Too High ORP Reading Too Low Check pH Tank Check ORP Tank Sanitizer Feed Locked pH Feed at Limit ORP Feed at Limit Invalid Hardware Config IntelliChlor Communication Error Memory Errors Calibration Failed Communication Lost SI Corrosive SI Scaling Screen Logic Message 50 Cross Reference 51 Tweaking pH (Calibrating) Measure the pH using a standard test kit by taking several readings and averaging the results. To Tweak the pH sensor see page 12. Tweaking ORP (Calibrating) Always make sure the pH is at the set point before calibrating ORP. Always control at PPM levels greater than 1.0 PPM when using ORP sensors. IMPORTANT: For best results the ORP should be at the ORP set point when calibrating. For best results the PPM should be at the desired level when calibrating ORP. To Tweak the ORP sensor see page 15. IntelliChem Specifications RATINGS: Input Voltage: 120 VAC / 240 VAC 50/60 Hz 200 mA / 100 mA or 0.2 A / 0.1 A Relay Rating: Dry Contact 5 A, 120 VAC / 30 VDC Temperature:Min./Max. Operating Temperature 30° - 110° F Sensor Range: pH 4.0 - 9.99 - ORP 0 - 999mV Flow Open or Closed MAINTENANCE Winterizing: The Flow Cell sensors must be protected from freezing conditions. If the pool is winterized, plan to remove and store the sensors (as described above) as part of the normal pool winterizing process. The Flow Cell and related plumbing must be drained as well. Water Chemistry Always test water chemistry with a quality manual test kit. Therefore, it may be preferable to calibrate pH using commercially available reference solutions. If required, use the IntelliChem Tweak pH feature to periodically adjust the pH reading (see above and page 12). It’s important to note that changes in pH, cyanuric acid concentration, total dissolved solids, and use of additional or alternative sanitizers will all affect the primary sanitizer residual level relative to ORP. Maintain total alkalinity on regular basis to ensure pH stability. To maintain a consistent sanitizer residual in parts per million (ppm), periodically adjust the ORP level. Sensor Maintenance: The Flow Cell sensors must be clean and free from oil, chemical deposits and contamination to function properly. After saturation in pool or spa water, the sensors may need to be cleaned on a weekly or monthly basis depending on bather load and other pool specific characteristics. Slow response, increased need to calibrate pH, and inconsistent readings are indications that the probes are in need of cleaning. INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 52 MAINTENANCE (Continued) Cleaning the Flow Cell Sensors: To clean the ORP and pH sensors, turn off the AC source power to IntelliChem at the GFCI switch. Disconnect the probe connectors from the Flow Cell, unscrew the probe and carefully remove them from the Flow Cell. Clean the reference junction (the white ring at the bottom of the probe body) with a soft toothbrush. A household liquid dish washing detergent may also be used to remove any oil. Rinse with fresh water and reinstall probes. If properly cleaned probes continue to provide unstable readings or require excessive calibration, the probes should be replaced. Probe exposed to atmospheric conditions will cause the probe tips to dry out. Store the sensors with the included plastic sensors storage caps if removed from the Flow Cell for more than one hour. If the storage caps have been misplaced, store the probes individually in small glass or plastic containers with clean water covering the sensor tips. Store sensors in a location that will not be subjected to freezing temperatures. Sensor Care Contamination of the sensing elements often results in slow response and inaccurate readings. Clean the elements by the following procedures: pH and ORP Sensors 1. Wash electrode tip in a liquid detergent and water. Carefully use a soft bristled toothbrush to wash the electrode tip and white sensing ring. 2. Rinse after cleaning. To reinstall the flow cell (see page 33). Hand tighten to sensors to secure in place. 3. Make sure the O-ring is installed on sensor. 4. If the cable is longer than needed, it should be coiled neatly and attached under the enclosure. pH Sensors Only 5. Attempt to clean the sensor with liquid detergent first. 6. If this is not successful, swirl the tip of the sensor in a 5 parts water and 1 part muriatic acid solution for 10 - 20 seconds. 7. Rinse again and reinstall. WARNING Do not rub hard the glass element in the sensor or use sand paper or other polishing material to clean. HANDLE ELECTRODE CAREFULLY Sensors contain external and internal glass elements. Do not drop or otherwise subject the sensor to vibration, physical impact, or freezing conditions. ANY TYPE OF BREAKAGE IS NOT COVERED UNDER WARRANTY. pH and ORP Sensors: pH electrodes sense the acidity of the water and work with any acid or base. The blue bands on the cables identify the pH sensors. The red bands on the cables identify ORP sensors. Each sensor is also identified on the sensor body. ORP electrodes are used to monitor the Oxidation Reduction Potential (ORP is sanitization quality of the water) of a given solution. The sensing element of the ORP electrode is made of a precious metal such as platinum or gold. Sensors: IntelliChem measures the following sensor measurements with the listed characteristics: pH Range: .................................................................................................................. 4.00 to 9.99 ORP Range: ............................................................................................................... 0 to 999 mV INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 53 Motor Pump Head Yearly Replacement IMPORTANT! Replace the IntelliChem pump head (P/N 521384Z) once a season (yearly). Pump Head Replacement (for single or multiple pumps) Disconnect AC power to IntelliChem® Controller enclosure at the circuit breaker before servicing. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock. 1. STOP THE MAIN POOL FILTERPUMP. 2. First loosen the Jaco fitting on the OUTLET tube. Carefully disconnect the tube. Keep the tube pointed upward to keep the chemical from spilling out the top of the tube. 3. Connect the tube to the OUTLET of the new pump head Jaco fitting. Secure the tube. 4. Repeat Step 1 and 2 for the INLET tube. 5. Remove the upper and lower screws securing the old pump head and remove the pump head from the motor assembly. 6. Install the new pump head (with attached tubes) to the motor assembly. Secure the pump head with the two screws. Screws Pump head with tube, Jaco fitting and screws (P/N 521348Z). Output tube (Jaco fitting) Inlet tube (Jaco fitting) INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 54 IntelliChem® Controller Replacement 1. P/N 521465Z - Top Half (Lid with overlay and wiring diagram). 2. P/N 521319Z - IntelliChem Controller Circuit Board. 3. P/N 8520031Z - Circuit Breaker. 4. *P/N 521348Z - Pump head Jaco fitting with tube and screws. 5. P/N 521466Z - Jaco fitting. 6. P/N 521467Z - Enclosure mounting brackets. 7. P/N 521338Z - Pump motor. 8. P/N 521468Z - Strain relief kit. 9. P/N 521335Z - Replacement transformer with mounting plate. Note: (*) MUST REPLACE ONCE A SEASON (YEARLY). 1 2 3 9 4 7 6 8 Warranty Information The IntelliChem controller has a one year limited warranty. For more information contact Customer Support (800) 831-7133 INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 5 55 IntelliChem® Controller Flow Cell Replacement Parts List 1. 2. 3. 4. 5. 6. 7. 8. 9. P/N 744000260 - Sensor, pH P/N 744000390 - Sensor, ORP P/N 754000310 - Flow Cell with Flow Switch Sensors P/N 521342Z - IntelliChem Controler Parts Bag (not shown) P/N 754000440 - Flow Switch Sensor P/N 744000290 - Cable, pH 2 ft 6 P/N 744000360 - Cable, ORP 2 ft P/N 744000280 - Cable, pH 10 ft (optional) P/N 744000350 - Cable, ORP 10 ft (optional) 7 1 2 23 5 3 Warranty Information The IntelliChem pH sensor and ORP sensor each have a two year limited warranty. The IntelliChem pump head, pH sensor and ORP sensor are considered wear items and are covered by their own warranty periods and are not part of any extended warranty coverage. For more information contact Customer Support (800) 831-7133 INTELLICHEM® Water Chemistry Controller Installation and User’s Guide 1620 HAWKINS AVE., SANFORD, NC 27330 • (919) 566-8000 10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 • (805) 553-5000 WWW.PENTAIRPOOL.COM All Pentair trademarks and logos are owned by Pentair, Inc. Pentair Aquatic Systems™, IntelliFlo®, MobileTouch®, EasyTouch®, IntelliTouch® and IntelliChem® are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. © 2012 Pentair Aquatic Systems. All rights reserved. This document is subject to change without notice. *521363* P/N 521363 REV. C 10/22/12