Lightrail Complete Catalog Section

advertisement
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
Cole Lightrail systems are versatile and
functional illuminated handrails, suitable for
interior or exterior guardrails and stair or ramp
railings. Lightrail projects light where it is
needed and is available with asymmetrical or
symmetrical light distribution patterns. Lightrail
may be wall or post mounted, or it may be
provided to coordinate with a handrailing system
by another manufacturer. Matching nonilluminated railings are also offered for each
series. Cole Lightrail is specifically designed and
fabricated for every installation, and is listed as
Suitable for Wet Locations by Underwriters
Laboratories, Inc..
Lightrail is designed and engineered to
withstand the abuse of most public areas.
Design features comply with the Americans with
Disabilities Act (ADA) requirements and other
In addition to our five
standard series of
Lightrail, Cole can
design and fabricate
unique custom
railings to suit your
project requirements.
applicable codes. The high impact acrylic lenses
are housed within thick heavy extruded aluminum
rails. All rails are welded at mitered intersections
for additional strength and durability.
We will also develop modified or custom
illuminated railings to your exact specifications.
To learn more about our custom capabilities
and comprehensive range of standard lighting
fixtures, call us directly or contact your local
Cole representative.
Lightrail provides subtle
illumination where
it is needed without
distracting from other
architectural features.
Lightrail with its
many options and
design flexibility
can accomodate
unusualapplications.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 1 Series Lightrail
LR 2 Series Lightrail
LR 3 Series Lightrail
The asymmetrical design of the LR 1
Series projects illumination sideways while
effectively reducing light spill to the
background. This unique feature makes
LR 1 ideal for wall mounting on stairs or
ramps or as guardrail on pedestrian
bridges. The optional griprail meets ADA
and code size requirements.
The symmetrical design of the LR 2
Series provides a balanced light
distribution pattern, with light projecting
equally to both sides. The fluorescent
ballast is mounted above the lamps in
this series, providing maximum light
continuity. The optional griprail meets
ADA and code size requirements.
The LR 3 Series, with its round crosssection, is the most popular of the Lightrail
systems offered by Cole. The simple rail
extrusion allows it to be configured to suit
most applications. The symmetrical design
provides broad illumination to both sides.
The optional griprail meets ADA and code
size requirements.
LR 4 Series Lightrail
LR 5 Series Lightrail
The LR 4 Series is a modification of the
LR 2 Series which reduces the height to 5"
(127mm) and has an elliptical rounded top.
Its performance characteristics are identical
to the LR 2 Series.
The unique design of the LR 5 Series
provides symmetrical illumination from a
design which is small enough to conform
to ADA requirements for the grip surface of
the handrail.
QB 3M G04
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 1W Wall Mounted
LR 1P Post Mounted
LR 1 Lightrail
produces an
asymmetrical light
distribution pattern
that washes walkways
with light while
reducing illumination
to the background.
Optional griprail
may be specified for
mounting on the top
of the Lightrail when
required by ADA or
other codes.
Description
LR1 Series Lightrail is a flexible system of wall
or post mounted illuminated handrails. This
asymmetrical design projects illumination to one
side along walkways and stairways. LR 1 Series
Lightrail is complementary to the LR 2 Series,
which should be used when a symmetrical light
pattern is required. Companion non-illuminated
Lightrail is also available. Design features
comply with ADA and other codes.
Features
An angled, high impact acrylic lens provides an
asymmetrical illumination pattern that effectively
reduces light to the background. To ease maintenance the lens prisms are on the lamp side.
Illumination is provided by T5 or T8 fluorescent
lamps. The extruded aluminum rail is welded
at all intersections and features cast aluminum
wall mounting brackets or extruded aluminum
posts. The standard finish is a polyester coating,
available in a wide range of colors. The optional
griprail with smaller dimensions meets
ADA requirements.
Applications
LR 1 Lightrail is ideal as guardrails on pedestrian bridges and stair and ramp railings.
Custom
We would be pleased to discuss the production
of modified standard Lightrail or custom railings
to suit your specific conditions. Modifications
possible include custom extrusions, alternate
finishes or materials, mounting adaptions, end
treatments and alternate light sources.
To learn more about our custom capabilities and
standard product lines call us directly or contact
your local Cole representative.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 1W Wall Mounted
LR 1P Post Mounted
Specifications
Construction
• Railing is extruded .125" wall, 6063-T5 aluminum • Posts are 3" square, .125" wall extruded
aluminum tubing • Wall brackets are cast aluminum • Clear, prismatic snap-in lens is extruded
high-impact acrylic with prisms on the inside for
better maintenance • Ends and all railing miters
are welded and ground smooth • Optional griprail is 1.66" diameter x 0.19" wall aluminum pipe
with cast aluminum support • Medium bronze polyester coating is the standard finish; other colors
and finishes are available.
T8 lamp illustrated
Sample Field Confirmation Drawing provided by
Cole for each installation prior to fabrication.
Field measuring instructions are available.
Electrical
• Prewired for T5 or T8 fluorescent lamps with
120V-277V standard (347V available) electronic
0° F (-18° C) ballasts • Lamping will be determined by the factory to ensure maximum even
illumination • Other lamping available for special applications • Ballasts in T5 lamp models
are above the lamp, allowing continuous illumination • Ballasts in T8 lamp models are in-line
with lamps in railing, and that area is non-illuminated • cULus listed suitable for wet locations.
Performance
6"
4" sq.
Direct burial (standard)
6" sq.
Optional baseplate (-BP)
10-fc
5-fc
Two 32 watt T8 fluorescent lamps
Mounting height: 34" to top of rail
2-fc
Readings in footcandles: 24" grid
1-fc
IES format photometric files are available.
Options
How to Specify
Griprail: 1.66" diameter. Add suffix -H.
Baseplate: 6" x 6" x 3/8" baseplate with four 5/8"
holes. Add suffix -BP.
Pickets: 3/4" pickets, 4 3/4" on center, top rail
4" below bottom of Lightrail, bottom rail 4" above
ground. Add suffix -K.
Non-illuminated: Without lighting components.
Add suffix -U.
Finishes: Special finishes are available;
contact factory.
Emergency Battery: Provides battery operation
for up to 90 minutes during power outage for all
or selected lamps. Add suffix -EM.
Every Lightrail is custom designed and
fabricated to your specific project conditions.
Architectural drawings are required that clearly
show the desired configurations and locations.
A detailed drawing (similar to the sample above)
will be provided by Cole prior to fabrication for
your field verification.
1. Give catalog number, options, lamp size, and
voltage. Example: LR 1P-H-T5-120. Lamping
will be determined by the factory to maximize
even illumination.
2. Select desired options and add
appropriate suffixes.
QB 3M G04
Mounting
• Posts are provided to a maximum of 8' centers,
wall brackets provided up to 6' centers, subject
to spacing requirements of the particular installation • Posts are provided with extra 6" length
for direct burial and 4" square x 6" styrofoam
forms for precasting hole; contractor to finish
with quick-setting concrete • 6" x 6" x 3/8"
baseplate with four 5/8" holes is available as
an option • Wall bracket allows mounting over
conduit stub.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 2W Wall Mounted
LR 2P Post Mounted
LR 2 Lightrail produces
a symmetrical light
distribution pattern that
washes walkways with
light to both sides.
Optional griprail
may be specified for
mounting on the top
of the Lightrail when
required by ADA or
other codes.
Description
LR 2 Series Lightrail is a flexible system of wall
or post mounted illuminated handrails with a
symmetrical design. It projects illumination
equally to both sides. LR 2 Series Lightrail is
complementary to the LR 1 Series, which should
be used when an asymmetrical light pattern is
required. Companion non-illuminated Lightrail
is also available for this series. Design features
comply with ADA and other codes.
Features
A high impact acrylic lens provides a symmetrical illumination pattern that effectively washes
walkways with light to both sides. To ease maintenance the lens prisms are on the lamp side.
Illumination is provided by T8 fluorescent lamps
with the ballasts positioned above the lamps to
maximize continuous uninterrupted light. The
heavy extruded aluminum rail is welded at all
intersections and features cast and extruded aluminum wall mounting brackets or extruded aluminum posts. The optional griprail with smaller
dimensions meets ADA requirements.
Applications
LR 2 Lightrail is ideal as guardrails, stair and
ramp railings as well as elevator railings.
Custom
We would be pleased to discuss the production
of modified standard Lightrail or custom railings
to suit your specific conditions. Modifications
possible include custom extrusions, alternate
finishes or materials, mounting adaptions, end
treatments and alternate light sources.
To learn more about our custom capabilities and
standard product lines call us directly or contact
your local Cole representative.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 2W Wall Mounted
LR 2P Post Mounted
Specifications
Construction
• Railing is extruded .125" wall, 6063-T5 aluminum • Posts are 3" square, .125" wall extruded
aluminum tubing • Wall brackets are 4" square at
electrical feed locations, 4" x 2" at other locations
• Brackets are .125" wall extruded aluminum tube
with cast aluminum wall plate • Clear, prismatic
snap-in lens is extruded high-impact acrylic with
prisms on the inside for better maintenance
• Ends and all railing miters are welded and
ground smooth • Optional griprail is 1.66" diameter x 0.19" wall aluminum pipe • Medium bronze
polyester coating is the standard finish; other
colors and finishes are available.
Sample Field Confirmation Drawing provided by Cole for
each installation prior to fabrication.
Field measuring instructions are available.
Electrical
• Prewired for T8 rapid start fluorescent lamps
with 120V-277V standard (347V available),
0° F (-18° C) electronic ballasts • Lamping will
be determined by the factory to ensure maximum
even illumination • Other lamping available for
special applications • Ballasts in LR 2 models are
above lamps, permitting uninterrupted illumination • cULus listed suitable for wet locations.
Performance
6"
4" sq.
Direct burial (standard)
Two 32 watt T8 fluorescent lamps
Mounting height: 34" to top of rail
10-fc
5-fc
2-fc
6" sq.
Optional baseplate (-BP)
1-fc
Readings in footcandles: 24" grid
IES format photometric files are available.
Options
How to Specify
Griprail: 1.90" diameter. Add suffix -H.
Baseplate: 6" x 6" x 3/8" baseplate with four 5/8"
holes. Add suffix -BP.
Pickets: 3/4" pickets, 4 3/4" on center, top rail 4"
below bottom of Lightrail, bottom rail 4" above
ground. Add suffix -K.
Non-illuminated: Without lighting components.
Add suffix -U.
Finishes: Special finishes are available;
contact factory.
Emergency Battery: Provides battery operation for
up to 90 minutes during power outage for all or
selected lamps. Add suffix -EM.
Every Lightrail is custom designed and fabricated to your specific project conditions.
Architectural drawings are required that clearly
show the desired configurations and locations.
A detailed drawing (similar to the sample above)
will be provided by Cole prior to fabrication for
your field verification.
1. Give catalog number, options, and voltage.
Example: LR 2W-H-277. Lamping will be
determined by the factory to maximize
even illumination.
2. Select desired options and add
appropriate suffixes.
QB 3M G04
Mounting
• Posts are provided to a maximum of 8' centers,
wall brackets provided up to 6' centers, subject
to spacing requirements of the particular installation • Posts are provided with extra 6" length for
direct burial and 4" square x 6" styrofoam forms
for pre-casting hole; contractor to finish with
quick-setting concrete • 6" x 6" x 3/8" baseplate
with four 5/8" holes is available as an option • 4"
square wall bracket allows mounting over conduit
stub • Wall bracket mounting bolts (by others)
are concealed.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 3W Wall Mounted
LR 3P Post Mounted
LR 3 Lightrail produces
a symmetrical light
distribution pattern that
washes walkways with
light to both sides.
Description
LR 3 Series Lightrail is a flexible system of wall
or post mounted illuminated handrails. The symmetrical design projects equal illumination to
both sides. With its simple round extrusion, LR
3 Series can be configured to suit most applications. Companion non-illuminated Lightrail is
also available. Design features comply with ADA
and other codes.
Features
A high impact acrylic lens provides a balanced
symmetrical illumination pattern that effectively
washes walkways with light to both sides. To
ease maintenance the lens prisms are on the
lamp side. Illumination is provided by T5 or T8
fluorescent lamps. The heavy extruded aluminum construction is available with several end
treatments options. LR 3 is welded at all angle
transitions. The standard finish is a polyester
coating, available in a wide range of colors. The
optional griprail with smaller dimensions meets
ADA requirements.
Applications
LR 3 Lightrail is ideal as guardrails, stair and
ramp railings as well as elevator railings.
Custom
We would be pleased to discuss the production
of modified standard Lightrail or custom railings
to suit your specific conditions. Modifications
possible include custom extrusions, alternate
finishes or materials, mounting adaptions, end
treatments and alternate light sources.
To learn more about our custom capabilities and
standard product lines call us directly or contact
your local Cole representative.
An optional griprail
may be mounted to
the top or sides of
the Lightrail when
required by codes.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
Optional Top
Griprail -H
LR 3W Wall Mounted
LR 3P Post Mounted
Specifications
Optional side Griprail: one
side, -1H; both sides, -2H.
Rails join with horizontal 180°
bend at ends
Construction
• Railing is extruded .156" (min.) wall, 6063-T5
aluminum • Posts are 3 1/2" diameter, .215"
wall extruded aluminum pipe • Wall brackets are
cast aluminum • Clear, prismatic snap-in lens
is extruded high-impact acrylic with prisms on
the inside for better maintenance • Ends and all
railing miters are welded and ground smooth
• Optional griprail is 1.66" diameter x 0.19"
wall aluminum pipe • Medium bronze polyester
coating is the standard finish; other colors and
finishes are available.
Shown with T8 lamp
Sample Field Confirmation Drawing provided by Cole
for each installation prior to fabrication.
Field measuring instructions are available.
Electrical
• Prewired for T5 or T8 fluorescent lamps with
120V-277V standard (347V available) electronic 0° F (-18° C) ballasts • Lamping will be
determined by the factory to ensure maximum
even illumination • Other lamping available
for special applications • Ballasts in T5 lamp
models are above the lamp, allowing continuous illumination • Ballasts in T8 lamp models
are in-line with lamps in railing, and that area is
non-illuminated • cULus listed suitable for
wet locations.
Performance
Radius end (-RE)
10-fc
5-fc
Two 32 watt T8 fluorescent lamps
Mounting height: 34" to top of rail
2-fc
Miter end (-ME)
6"
1-fc
Readings in footcandles: 24" grid
IES format photometric files are available.
5" dia.
Direct burial (standard)
6" sq.
Optional baseplate (-BP)
Options
How to Specify
Griprail: 1.66" diameter. To specify: Top: add
suffix -H; Sides: add suffix -1H or -2H.
Baseplate: 6" x 6" x 3/8" baseplate with four
5/8" holes. Add suffix -BP.
Pickets: 3/4" pickets, 4 3/4" on center, top rail
4" below bottom of Lightrail, bottom rail 4" above
ground. Add suffix -K.
Non-illuminated: Without lighting components.
Add suffix -U.
Finishes: Special finishes; contact factory.
Emergency Battery: Provides battery operation
for up to 90 minutes during power outage for all
or selected lamps. Add suffix -EM.
Every Lightrail is custom designed and fabricated to your specific project conditions.
Architectural drawings are required that clearly
show the desired configurations and locations.
A detailed drawing (similar to the sample above)
will be provided by Cole prior to fabrication for
your field verification.
1. Give catalog number, options, lamp size, and
voltage. Example: LR 3P-H-RE-T8-120. Lamping
will be determined by the factory to maximize
even illumination.
2. Select desired options and add
appropriate suffixes.
QB 3M G04
Mounting
• Posts are provided to a maximum of 8' centers,
wall brackets provided up to 6' centers, subject
to spacing requirements of the particular installation • Posts are provided with extra 6" length
for direct burial and 5" diameter x 6" styrofoam
forms for precasting hole; contractor to finish
with quick-setting concrete • 6" x 6" x 3/8"
baseplate with four 5/8" holes is available as
an option • Wall bracket allows mounting over
conduit stub.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 4W Wall Mounted
LR 4P Post Mounted
LR 4 Lightrail
produces a
symmetrical
light distribution
pattern that washes
walkways with light
to both sides.
Description
LR 4 Series Lightrail is a flexible system of wall
or post mounted illuminated handrails with a
curved top design. It projects illumination equally to both sides. Companion non-lluminated
Lightrail is also available for this series. Design
features comply with ADA and other codes.
Features
A high impact acrylic lens provides a symmetrical illumination pattern that effectively washes
walkways with light to both sides. To ease maintenance the lens prisms are on the lamp side.
Illumination is provided by T8 fluorescent lamps
with the ballasts positioned above the lamps to
maximize continuous uninterrupted light. The
heavy extruded aluminum rail is welded at all
intersections and features cast and extruded aluminum wall mounting brackets or extruded aluminum posts. The optional griprail with smaller
dimensions meets ADA requirements.
Applications
LR 4 Lightrail is ideal as guardrails, stair and
ramp railings as well as elevator railings.
Custom
We would be pleased to discuss the production
of modified standard Lightrail or custom railings
to suit your specific conditions. Modifications
possible include custom extrusions, alternate
finishes or materials, mounting adaptions, end
treatments and alternate light sources.
To learn more about our custom capabilities and
standard product lines call us directly or contact
your local Cole representative.
Optional griprail
may be specified for
mounting on the top
of the Lightrail when
required by ADA or
other codes.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 4W Wall Mounted
LR 4P Post Mounted
Specifications
Construction
• Railing is extruded .125" wall, 6063-T5
aluminum • Posts are 3" square, .125" wall
extruded aluminum tubing • Wall brackets are
cast aluminum • Clear, prismatic snap-in lens
is extruded high-impact acrylic with prisms on
the inside for better maintenance • Ends and all
railing miters are welded and ground smooth
• Optional griprail is 1.66" diameter x 0.19"
wall aluminum pipe • Medium bronze polyester
coating is the standard finish; other colors and
finishes are available.
Sample Field Confirmation Drawing provided by Cole for
each installation prior to fabrication.
Field measuring instructions are available.
Electrical
• Prewired for T8 rapid start fluorescent lamps
with 120V-277V standard (347V available),
0° F (-18° C) electronic ballasts • Lamping
will be determined by the factory to ensure
maximum even illumination • Other lamping
available for special applications • Ballasts in
LR 4 models are above lamps, permitting uninterrupted illumination • cULus listed suitable for
wet locations.
Performance
6"
4" sq.
Direct burial (standard)
Two 32 watt T8 fluorescent lamps
10-fc
5-fc
2-fc
Mounting height: 34" to top of rail
6" sq.
Optional baseplate (-BP)
1-fc
Readings in footcandles: 24" grid
Mounting
• Posts are provided to a maximum of 8' centers, wall brackets provided up to 6' centers,
subject to spacing requirements of the particular
installation • Posts are provided with extra 6"
length for direct burial and 4" square x 6" styrofoam forms for pre-casting hole; contractor
to finish with quick-setting concrete • 6" x 6" x
3/8" baseplate with four 5/8" holes is available
as an option • Wall bracket mounting bolts (by
others) are concealed.
IES format photometric files are available.
Options
How to Specify
Griprail: 1.66" diameter. To specify, add suffix -H.
Baseplate: 6" x 6" x 3/8" baseplate with four 5/8"
holes. Add suffix -BP.
Pickets: 3/4" pickets, 4 3/4" on center, top rail 4"
below bottom of Lightrail, bottom rail 4" above
ground. Add suffix -K.
Non-illuminated: Without lighting components.
Add suffix -U.
Finishes: Special finishes; contact factory.
Emergency Battery: Provides battery operation
for up to 90 minutes during power outage for all or
selected lamps. Add suffix -EM.
Every Lightrail is custom designed and fabricated to your specific project conditions.
Architectural drawings are required that clearly
show the desired configurations and locations.
A detailed drawing (similar to the sample above)
will be provided by Cole prior to fabrication for
your field verification.
1. Give catalog number, options, and voltage; LR
4W-EM-277. Lamping will be determined by the
factory to maximize even illumination.
2. Select desired options and add
appropriate suffixes.
QB 3M C08
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
LR 5W Wall Mounted
LR 5P Post Mounted
LR 5 Lightrail produces
a symmetrical light
distribution pattern that
washes walkways with
light to both sides.
LR 5 Series Lightrail is a flexible system of wall
or post mounted illuminated handrails. The
unique design provides symmetrical illumination from a design which is small enough to
conform to ADA requirements* for the grip
surface of the handrail.
Features
Fluorescent models have a high impact acrylic
lens providing a symmetrical illumination pattern using T5 lamps. Light emitting diode (LED)
models have a sealed extruded polycarbonate
tube with LEDs that fits flush with the rail. Linear
prisms spread the illumination symmetrically.
The extruded aluminum rail is welded at all intersections. Ballasts or LED drivers may be integral in the posts or railing, or may be remote.
LR5 Lightrail installation may require additional
electrical feeds for each run, and early cordination with the factory is suggested to clarify
installation consideration.
Applications
LR 5 Lightrail is ideal as guardrails, stair and
ramp railings as well as elevator railings.
Custom
We would be pleased to discuss the production
of modified standard Lightrail or custom railings
to suit your specific conditions. Modifications
possible include custom extrusions, alternate
finishes or materials, mounting adaptions, end
treatments and alternate light sources.
To learn more about our custom capabilities and
standard product lines call us directly or contact
your local Cole representative.
* Access Board interpretation of ADA requirements considers 1¼"-1½" standard pipe
sizes to be acceptable. Standard 1½" pipe is
1.90" diameter.
Unique 1.9"
diameter complies
with ADA
requirements.
Fluorescent
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
LED
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
1 1/2"
(38mm)
4 1/4"
(108mm)
T
I
N
G
Illuminated Handrails
LR 5W Wall Mounted
LR 5P Post Mounted
Specifications
4" (102mm)
Post Mounted
Wall Mounted
Sample Field Confirmation Drawing provided by Cole
for each installation prior to fabrication.
Field measuring instructions are available.
Performance
Two 28 watt T5 fluorescent lamps
10-fc
5-fc
Mounting height: 36" to top of rail
2-fc
Stub End (-SE)
Miter End (-ME)
Loop End (-LE)
Radius End (-RE)
1-fc
Readings in footcandles: 24" grid
IES format photometric files are available.
Options
How to Specify
Baseplate: 5" x 5" x 3/8" baseplate with four
5/8" holes. Add suffix -BP.
Non-illuminated: All Lightrail models are available without lighting components. Add suffix -U.
Ends: Add suffix. Stub -SE. Miter -ME.
Loop -LE. Radius -RE.
LED Illumination: Add suffix -LED.
Bronze Construction: 385 architectural bronze
rail with #4 satin finish. Add suffix -BRZ.
Stainless Steel Construction: Add suffix -SS.
Every Lightrail is custom designed and fabricated to your specific project conditions.
Architectural drawings are required that clearly
show the desired configurations and locations.
A detailed drawing (similar to the sample above)
will be provided by Cole prior to fabrication for
your field verification.
1. Give catalog number, options, and voltage; LR
5W-RE-277. Lamping will be determined by the
factory to maximize even illumination.
2. Select desired options and add
appropriate suffixes.
QB 3M H08
Construction
• Railing is extruded 6063-T5 aluminum,
bronze, or stainless steel • Posts are 2 3/8"
diameter aluminum pipe or bronze • Wall
brackets are fabricated aluminum or bronze
• Clear, prismatic snap-in lens is extruded
high-impact acrylic with prisms on the inside
for better maintenance • Ends and all railing
miters are welded and ground smooth • Medium bronze polyester coating is the standard
finish on aluminum other finishes are available • Optional bronze has #4 satin finish.
Electrical
• Fluorescent: prewired for T5 rapid-start
fluorescent lamps, available in various
lengths, as required • Lamping will be determined by factory to ensure maximum even
illumination • LED: prewired for LED strips
and drivers • Electronic 0°F (-18°C) ballasts
may be integral in railing or posts, or remotemounted for greater continuity of illumination
• Suitable for wet locations • cULus listed
suitable for wet locations.
Mounting
• Posts or wall brackets are provided to a
maximum of 6' centers • Posts are direct
buried to 6" depth and set with quick-setting
grout by contractor • Baseplates are optional
for post mounting • Wall bracket allows
mounting over conduit stub flush with wall.
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
Instructions for field-measuring Lightrail installations
In order to properly manufacture Lightrail illuminated handrail to match field conditions, dimensions taken from
the finished surfaces must be obtained to allow company engineers to accurately depict the cross-section
profile of the location. The critical data are the pitch, overall nose-to-nose dimension, and the bottom riser
height. The dimensions are most easily obtained with two people working.
Submittal drawings from Cole typically are drawn to the dimensions provided on architectural details, but the
actual dimensions are left open for field verification, as indicated by a lettered circle in the dimension lines. It
is extremely important to furnish the required dimensions measured exactly as indicated, e.g., horizontally,
vertically, or at the angle, as indicated. Dimensions should be taken exactly as the final rail is to run, i.e.,
directly below the centerline.
If only the concrete subsurface is in place, but brick or stone pavers are to be added later, do not attempt to
make measurements. The results will not be accurate; consult factory for advice.
Where the rails are to continue across landings, the pitch of the landings must be determined.
The following instructions are generally described for post-mounted applications. Special considerations for
wall-mounted applications are given at the end.
In a drawing the cross-section profile appears thus:
Note that the individual tread and riser dimensions are not requested. Using them usually introduces significant
error.
If one or more intermediate posts are required, additional nose-to-nose and nose-to-centerline data are
necessary.
1
C
O
L
E
L
I
G
H
T
I
N
G
The overall nose-to-nose dimension and bottom riser height are easily measured with a conventional measuring tape.
Pitch is the difficult value to determine. Using simple trigonometric functions (our calculators do this work),
the angle can be determined from the lengths of two sides of a right triangle. Individual tread and riser
heights, uniform on a drawing, are not uniform in real life. Do not determine pitch from “typical” tread and
riser measurements.
Since c has already been established when obtaining the overall nose-to-nose dimension, only a or b need to
be determined to complete the calculation. Vertical dimension b is the easiest to measure and more reliably
provides an accurate dimension.
To measure side b, use a carpenter’s level, as long as obtainable. Place one end on the nose of the top tread
and hold it level out over the descending stairs. Measure straight down from the bottom of the level to the nose
of the lowest tread over which the level spans. A visual determination of the vertical orientation of the measuring
tape is sufficient.
In some situations the length of the stairs will be too long for the carpenter’s level to span. In these situations,
sufficient accuracy is obtained from the greatest length convenient to measure. Use the method given above
for dimension b. For dimension c, measure the nose-to-nose dimension for the two treads used with the
carpenter’s level. These two lengths will compute the pitch. Note that three or four treads can represent the
pitch of the overall stairs. If measuring a ramp, the same principle applies. Use the full length of the carpenter’s
level from any arbitrary mark on the ramp to a mark directly below the opposite end. The vertical dimension b
is measured as above, and the length of the level becomes dimension a.
In most cases, the locations of the top and bottom posts are determined by the code requirements for the rail
itself, and the appropriate dimensions will be provided by Cole. However, some jobs will require that the posts
be in specific locations to coordinate with architectural features, so those locations must be provided to Cole.
These dimensions are measured from the nearest risers to the post centerlines. If there are intermediate
posts, additional nose-to-nose measurements must be made for each tread on which a post is to be mounted.
The nose-to-centerline length is then measured for each affected tread.
2
C
O
L
E
L
I
G
H
T
I
N
G
There is a potential pitfall at the bottom riser. Many risers have an undercut, or lip, in their design. For our
purposes, we must know the horizontal dimension from the top (nose) of the riser to the centerline. The
carpenter’s level is helpful here.
Be sure to indicate which post location is the electrical feed location. The contractor must allow sufficient wire
to make his connections in the ballast compartment in the Lightrail.
For wall-mounted applications, there is usually some end treatment which requires knowledge of the pitch just
as with post-mounted handrails, so the same dimensions are required. Determination of the feed location is
critical. It is measured relative to either the top riser or the bottom riser. Ideally, it is at the top over the level
approach, i.e., before the top riser. At this location, its height is determined from the architect’s specified
height to the top of the rail and the offset down given in the catalog literature for the specified Lightrail model.
The Cole submittal drawing should indicate the feed location to ensure its proper placement at a bracket
location.
Note that the model LR5W Lightrail usually requires remote ballasts and requires more than one feed for
longer runs. These feed points must be closely coordinated with the factory and precisely placed on the job.
Lightrail installations can be tricky and the final product is very inflexible. Following these instructions should
provide accurate information on the first try for most field situations. Always review the submittal drawings and
be sure to carefully provide every dimension requested, as indicated by the lettered circles and dimension
grid. Read the notes on the drawing which may request additional information. Special conditions such as
corners, pavers, landings, sloped bottom levels, etc., require special considerations. In these situations, always
contact the factory for specific instructions.
ing
t
h
i
g
L
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
3
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
Illuminated Handrails
Lightrail provides
subtle illumination
exactly where it
is needed without
distracting from
other architectural
features.
In addition to our
five standard series
of Lightrail, Cole
can design and
fabricate unique
custom railings to
suit your project
requirements.
Lightrail with its
many options and
design flexibility can
accomodate unusual
applications.
Cole Lightrail systems are versatile and functional illuminated handrails, suitable for interior
or exterior guardrails and stair or ramp railings.
Lightrail projects light where it is needed and is
available with asymmetrical or symmetrical light
distribution patterns. Lightrail may be wall or
post mounted, or it may be provided to coordinate with a handrailing system by another manufacturer. Matching non-illuminated railings are
also offered for each series. Cole Lightrail is
specifically designed and fabricated for every
installation, and is listed as Suitable for Wet
Locations by cULus.
Lightrail is designed and engineered to withstand the abuse of most public areas. Design
features comply with the Americans with Disabilities Act (ADA) requirements and other applicable codes. The high impact acrylic lenses are
housed within heavy extruded aluminum rails.
All rails are welded at mitered intersections for
strength and durability.
We will also develop modified or custom
illuminated railings to your exact specifications.
To learn more about our custom capabilities and
comprehensive range of standard lighting fixtures, call us directly or contact your local Cole
representative.
g
i
n
t
h
i
g
L
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
C
O
L
E
L
I
G
H
T
I
N
G
LR 1W Wall Mounted
LR 1P Post Mounted
Shown with optional Griprail -H
10-fc
5-fc
2-fc
1-fc
LR 1 Lightrail
projects light to one
side making it ideal
for wall applications
and pedestrian
bridges.
Description
LR 1 Series Lightrail is an asymmetrical design
that projects illumination to one side along walkways and stairways. The design provides a sharp
cutoff of light to the back side.
Features
An angled, high impact acrylic lens provides
an asymmetrical illumination pattern that effectively reduces light to the background. To ease
maintenance, the lens prisms are on the lamp
side. Illumination is provided by T8 fluorescent
lamps with the ballasts in-line with the lamps,
or T5 fluorescent lamps with the ballast above
the lamps. The extruded aluminum rail is welded
at all intersections and features cast aluminum
wall mounting brackets or extruded aluminum
posts. The standard finish is a polyester coating,
available in a wide range of colors. The optional
griprail with smaller dimensions meets ADA
requirements. Listed by cULus as Suitable for
Wet Locations.
Lamps: 2 x 32W T8 fluor.
Height: 34" to top of rail
Readings in footcandles:
Shown for 24" grid
LR 3W Wall Mounted
LR 3P Post Mounted
Fluorescent or LED
Shown with optional top Griprail -H or side Griprail -2H.
LR 3 Lightrail offers
the widest light
coverage and a soft
shape offering many
design variations.
10-fc
5-fc
2-fc 1-fc
Lamps: 2 x 32W T8 fluor.
Height: 34" to top of rail
Readings in footcandles:
Shown for 24" grid
Description
LR 3 Series Lightrail is a system of round illuminated handrails. This symmetrical design
projects illumination equally to both sides.
The wrap-around lens provides the greatest
light output.
Features
A high impact acrylic lens provides a balanced
symmetrical illumination pattern that effectively washes walkways with light to both sides.
To ease maintenance the lens prisms are on
the lamp side. Illumination is provided by
T8 fluorescent lamps with the ballasts in-line
with the lamps, or T5 fluorescent lamps with
the ballast above the lamps. LED models
have a sealed extruded polycarbonate tuve
with LEDs that fits flush with the rail. Linear
prisms spread the illumination symmetrically.
The extruded aluminum rail is welded at all
intersections and features cast aluminum wall
mounting brackets with concealed fasteners
or extruded aluminum posts. The standard
finish is a polyester coating, available in a
wide range of colors. The optional griprail with
smaller dimensions meets ADA requirements.
Listed by cULus as Suitable for Wet Locations.
C
O
L
E
L
I
G
H
T
I
N
G
LR 4W Wall Mounted
LR 4P Post Mounted
Description
LR 4 Series Lightrail is a flexible system of wall
or post mounted illuminated handrails with a
symmetrical design. The lens is not visible when
viewed from the side.
Features
A high impact acrylic lens provides a symmetrical illumination pattern that effectively washes
walkways with light to both sides. Illumination
is provided by T8 fluorescent lamps with the
ballasts positioned above the lamps to maximize continuous uninterrupted light. The heavy
extruded aluminum rail is welded at all intersections and features cast and extruded aluminum
wall mounting brackets or extruded aluminum
posts. The optional griprail with smaller dimensions meets ADA requirements. Listed by cULus as
Suitable for Wet Locations.
Shown with optional Griprail -H
LR 4 Lightrail has
a soft appearance
with complete light
cutoff to the sides.
10-fc
5-fc
2-fc 1-fc
Lamps: 2 x 32W T8 fluor.
Height: 34" to top of rail
Readings in footcandles:
Shown for 24" grid
LR 5W Wall Mounted
LR 5P Post Mounted
1.90"
(48mm)
1 1/2"
(38mm)
10-fc
5-fc 2-fc
1-fc
LR 5 Lightrail has a
unique small design
that is ADA compliant
and suitable for
indoor and outdoor
locations.
Stub End (-SE)
1 1/2"
(38mm)
4 1/4"
(108mm)
Miter End (-ME)
Height: 36" to top of rail
Shown for 24" grid
Description
LR 5 Series Lightrail is a system of wall or small round
illuminated handrails. The unique design provides
symmetrical illumination from a design which is small
enough to conform to ADA requirements* for the grip
surface of the handrail.
Features
Fluorescent models have a high impact acrylic lens
providing a symmetrical illumination pattern using T5
lamps. LED models have LEDs within a sealed extruded
polycarbonate tube that fits flush with the rail. Linear
prisms spread the illumination symmetrically. The
extruded rail is welded at all intersections. Ballasts, or
LED drivers may be in posts, or railing, or may be remote. LR5W Lightrail installation may require additional
electrical feeds for each run, and early cordination with
the factory is suggested to clarify installation considersations. Listed by cULus as Suitable for Wet Locations.
* Access Board interpretation of ADA requirements
considers 1¼"-1½" standard pipe sizes to be acceptable. Standard 1½" pipe is 1.90" diameter.
Lamps: 2x28W T5 fluor.
Readings in footcandles:
Aluminum, bronze, stainless steel
Fluorescent or LED
Loop End (-LE)
Radius End (-RE)
C
O
L
E
L
National Center for the Preservation of Democracy
I
G
H
T
I
N
G
Liberty Plaza
Dos Lagos
CUSTOM LIGHTRAIL
Cole Custom Lightrail systems are versatile and functional illuminated handrails, suitable for interior or exterior guardrails and stair or ramp railings.
Custom Lightrail projects light where it is needed and is available with asymmetrical or symmetrical light distribution patterns. Lightrail may be wall
or post mounted, or it may be provided to coordinate with a handrailing system by another manufacturer. Matching non-illuminated railings are also
offered. Custom Cole Lightrail is specifically designed and fabricated for every installation, and is listed as Suitable for Wet Locations by
Underwriters Laboratories, Inc..
Custom Lightrail is designed and engineered to withstand the abuse of most public areas. Many variation are available, such as LED, special mounting
brackets, infill panels, and multi-line rails. Custom models can also be fabricated in stainless steel and bronze. The high impact acrylic lenses are
housed within thick heavy extruded aluminum rails. All rails are welded at mitered intersections for additional strength and durability. Design features
comply with the Americans with Disabilities Act (ADA) requirements and other applicable codes.
To learn more about our custom capabilities and comprehensive range of standard lightrail, call us directly or contact your local Cole representative.
SPECIFICATIONS & DETAILS
Sample Field Confirmation Drawing provided by Cole
for each installation prior to fabrication.
Field measuring instructions are available.
Illustration shown for LR 2P-H-EE
Easement end (-EE)
Radius end (-RE) Miter end (-ME)
LR 3 End Options
Options
Griprail: Add suffix -H.
Baseplate: 6" x 6" x 3/8". Add suffix BP.
Pickets: 3/4" pickets, 4 3/4" C-C. Add suffix -K.
Non-illuminated: Add suffix -U.
Finishes: Special finishes are available;
contact factory.
QB 1M E08
Construction
• Railing is extruded .125" (min.) wall, 6063-T5 aluminum • Posts are aluminum tubing or pipe • Clear, prismatic snap-in lens is extruded high-impact acrylic with
prisms on the inside for better maintenance • Ends and
all railing miters are welded and ground smooth
• Optional griprail meets ADA and code requirements
for stairway and ramp applications • Medium bronze
polyester coating is the standard finish; other colors and
finishes are available.
Electrical
• Prewired for T5 or T8 fluorescent lamps with 120V
standard (277V available) 0°F electronic ballasts
• Lamping will be determined by the factory to ensure
maximum even illumination • Other lamping available
for special applications • Listed by UL/cUL as suitable
for wet locations.
Mounting
• Posts are provided to a maximum of 8' centers, (6' for
LR 5), wall brackets provided up to 6' centers, subject to
spacing requirements of the particular installation
• Posts are provided with extra 6" length for direct burial
and styrofoam form for pre-casting hole; contractor to
finish with quick-setting concrete • 6" x 6" x 3/8" baseplate with four 5/8" holes is available as an option.
How to Specify
Every Lightrail is custom designed and fabricated to
your specific project conditions. Architectural drawings
are required that clearly show the desired configurations
and locations. A detailed drawing (similar to the sample
at left) will be provided by Cole prior to fabrication for
your field verification.
1. Give catalog number and voltage. Lamping will be
determined by the factory to maximize even illumination.
2. Select desired options and add appropriate suffixes.
g
n
t
i
h
g
Li
C. W. Cole & Company, Inc.
2560 N. Rosemead Boulevard
South El Monte, CA 91733-1593
Fax
(626) 443-9253
Tel.
(626) 443-2473
info@colelighting.com
www.colelighting.com
Download