Systemtechnik Components and Units for RF and Microwave Technologies http://www.mts-systemtechnik.de About us Systemtechnik RF-systems and -units Data technology Mechanical products History Main products Competence 쮿 1980 MTS Mikrotechnik has been founded as a development and manufacturing company. 쮿 Signal dirstribution systems for own audio, video, RF and microwave, used for telecommunication, radio monitoring, satellite communication 쮿 Own design and production of RF-comp. and -systems 쮿 Development and production of active and passive components for high freq. technology 쮿 Soft- and hardware laboraty Certified with DIN ISO 9001 Joseph-Gänsler-Straße 8 D-86609 Donauwörth Phone 0906 / 70694-0 Fax 0906 / 6661 info@mts-systemtechnik.de www.mts-systemtechnik.de 1995 Changing from MTS Mikrotechnik to MTS Systemtechnik to follow the changed demands on the market. 쮿 Manufacturing of mech. components for aviation, for aerospace industry, RF-techn. as well as for optical industry 쮿 RF-development and -simulation laboratory 쮿 Big CNC-production center 쮿 CAD construction service 쮿 Modern production methods like CAM Today notable companies of the electronic industry all over europe belong to our customers: Copyright Technical subject to change. Illustrations similar. ALCATEL, Arpege Défense, AUDI, Bosch Telecom, CERN, Danet, DB Telematik, DESY, DLR, EADS, Ericsson, ESA, Eurocopter, Infineon, Leica, Lucent Technologie, ND SatCom, PTB, Rohde & Schwarz, Serco, SIEMENS, Thomson, T-Mobile, Vodafone 4 Coaxial relays Series R The coaxial relays of the series R and T-R are characterized through excellent RF-specifications and an enormous type variety. More than 100 000 different models can be selected. A short overview of the existing models is shown in the following chapter in this catalogue. Configurations Within the one-way and multi-way relays up to seven different basic configurations are available: 쮿 Without any supply voltage the contacts can be normally open (NO), terminated or connected to ground. 쮿 One contact can be normally closed, all others are open, terminated or connected to ground as desired. 쮿 All inputs and/or outputs are normally terminated. We also offer coaxial transfer and bypass relays with similar configurations. The codes used are: 쮿 RX for transfer relays 쮿 RY for bypass relays Switch configuration Available are coaxial 1-way-switches (SPST) to coaxial 12-way-switches (SP12T) as well as coaxial transfer and bypass switches (specials on request). Technical data (guaranted values at +25 °C) Switching time 10 ms max. Life cycles 106 cycles Operating temperature 0 to 50 °C (-55 to +85 °C on request) Maximum RF-power unterminated terminated 2 watts 0,3 watts (others on request) Coil current (per contact) Impedance All models can be offered with 50 Ω or 75 Ω impedance. at 5 volts = 50 mA at 12 volts = 20 mA at 24 volts = 10 mA Enclosure Aluminium alodyned (alodyne 1200) Frequency range We offer frequency ranges from DC to 1000MHz or higher (depending on the type). Control input There are six different control input version available: Coaxial connectors Following coaxial connectors are available: BNC female, TNC female, SMA female, 1.6/5.6 female and N female. Male RF-connectors are also available on request. Coil and supply voltage The coil voltage (control input F, G, C, X) is optional +5 V DC, +12 V DC or +24 V DC. Supply voltage for control inputs L and Z is +5 V DC. Control inputs The control input and the coil voltage are connected by means of DC-feedthrough filters or SUB-D connectors on request. Code Description C floating, one side on a common line Control signal Coil voltage G common ground Coil voltage F floating, each coil as separated connectors (only until SPDT available) Coil voltage X TTL-driver, switch at „1“ 0 / 5 V, switch at 5 V L TTL-driver, inverting, switch at „0“ 0 / 5 V, switch at 0 V Z with BCD-decoder TTL 0/5V Ordering information 6 Series R and T-R T - RT 2 - 7 T = only at cassette units Configuration Type of switch Impedance RO 1 SPST 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 70 dB 65 dB 60 dB 2 2-way-switch SPDT 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 70 dB 65 dB 60 dB 3 3-way-switch SP3T 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 70 dB 60 dB 50 dB 4 4-way-switch SP4T 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 70 dB 60 dB 50 dB 5 5-way-switch SP5T 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 70 dB 60 dB 50 dB 6 3-way-switch SP6T 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 65 dB 60 dB 50 dB 7 7-way-switch SP7T 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 65 dB 60 dB 50 dB 8 8-way-switch SP8T 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 80 dB 65 dB 60 dB 50 dB 9 9-way-switch SP9T 5 7 50 Ω 75 Ω 4 2 5 DC – 40 MHz DC – 200 MHz DC – 500 MHz 80 dB 65 dB 60 dB 10 10-way-switch SP10T 5 7 50 Ω 75 Ω 4 2 5 DC – 40 MHz DC – 200 MHz DC – 500 MHz 80 dB 65 dB 60 dB 11 11-way-switch SP11T 5 7 50 Ω 75 Ω 4 2 5 DC – 40 MHz DC – 200 MHz DC – 500 MHz 80 dB 65 dB 60 dB 12 12-way-switch SP12T 5 7 50 Ω 75 Ω 4 2 5 DC – 40 MHz DC – 200 MHz DC – 500 MHz 80 dB 65 dB 60 dB RX Transfer-switch 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 70 dB 60 dB 50 dB 40 dB RY 5 7 50 Ω 75 Ω 4 2 5 1 DC – 40 MHz DC – 200 MHz DC – 500 MHz DC – 1000 MHz 70 dB 60 dB 50 dB 40 dB RT If switch is out of order, all contacts are floating. If switch is out of order, all outputs are terminated. RM If switch is out of order, all outputs are grounded. RU If switch is out of order, one path is closed, all other contacts are floating. RA RK RV RX RY If switch is out of order, one path is closed, all other contacts are terminated. If switch is out of order, one path is closed, all other contacts are grounded The input and output ports are terminated, if contacts are not switched. Transfer-switch Bypass-switch Bypass-switch Frequency range Isolation min. 1 7 0 0 - C - Internal registration number for special manufacturing Insertion loss VSWR max. max. Style R-series T-series Coaxial connectors 0,1 dB 0,2 dB 0,3 dB 0,4 dB 1,1 : 1 1,2 : 1 1,4 : 1 1,5 : 1 1 1 1 1 like T2 like T2 like T2 like T2 0,2 dB 0,3 dB 0,5 dB 0,6 dB 1,1 : 1 1,2 : 1 1,6 : 1 1,6 : 1 2/2A* 2/2A* 2/2A* 2/2A* T2 T2 T2 T2 0,2 dB 0,3 dB 0,5 dB 1,0 dB 1,1 : 1 1,3 : 1 1,4 : 1 1,5 : 1 like 4 like 4 like 4 like 4 T3 T3 T3 T3 0,2 dB 0,4 dB 0,6 dB 1,0 dB 1,2 : 1 1,3 : 1 1,4 : 1 2,0 : 1 4 4 4 4 T4 T4 T4 T4 0,2 dB 0,4 dB 0,6 dB 1,5 dB 1,2 : 1 1,3 : 1 1,5 : 1 2,0 : 1 like 6 like 6 like 6 like 6 like T6 like T6 like T6 like T6 0,2 dB 0,4 dB 0,6 dB 1,5 dB 1,2 : 1 1,3 : 1 1,5 : 1 2,0 : 1 6 6 6 6 T6 T6 T6 T6 0,2 dB 0,4 dB 0,6 dB 1,5 dB 1,3 : 1 1,5 : 1 1,5 : 1 2,0 : 1 like 8 like 8 like 8 like 8 like T8 like T8 like T8 like T8 0,2 dB 0,4 dB 0,6 dB 1,5 dB 1,3 : 1 1,5 : 1 1,5 : 1 2,0 : 1 8 8 8 8 T8 T8 T8 T8 0,3 dB 0,6 dB 1,0 dB 1,3 : 1 1,5 : 1 1,7 : 1 like 10 like 10 like 10 like T10 like T10 like T10 0,3 dB 0,6 dB 1,0 dB 1,3 : 1 1,5 : 1 1,7 : 1 10 10 10 T10 T10 T10 0,3 dB 0,6 dB 1,0 dB 1,5 : 1 2,0 : 1 2,0 : 1 like 12 like 12 like 12 like T12 like T12 like T12 0,3 dB 0,6 dB 1,0 dB 1,5 : 1 2,0 : 1 2,0 : 1 12 12 12 T12 T12 T12 0,2 dB 0,5 dB 0,7 dB 1,0 dB 1,1 : 1 1,3 : 1 1,5 : 1 2,0 : 1 13 13 13 13 T13 T13 T13 T13 0,2 dB 0,5 dB 0,7 dB 1,0 dB 1,1 : 1 1,3 : 1 1,5 : 1 2,0 : 1 13 13 13 13 T13 T13 T13 T13 0 2 4 6 8 BNC f TNC f SMA f 1.6/5.6 f N f* *Other enclosures f=female Other coaxial connectors on request! Coil voltage Control input 0 1 2 C 5 V DC 12 V DC 24 V DC Coil voltage at control type C, G, Fand X optionally 5, 12 or 24 volts. At control type Z or L only a supply voltage of 5 V DC is possible. G Floating (one side on a common line) from SP3T standard Common ground * Enclosure 2A for switches with driver F Floating, each coil at seperated connectors (only up to SPDT) d other uencies an q e fr r e h ig H uest! ons on req configurati X TTL-Driver (switch at „1“) L TTL-driver, inverting (switch at „0“) Z With BCD-decoder TTL M2,5/5deep M2,5/5deep M2,5/5deep M2,5/5deep M2,5/5deep M2,5/5deep M2,5/5deep M2,5/5deep M2,5/5deep 12 RF-relays, 10 W, DC to 1000 MHz - SPDT-relays Series RU2 쮿 Change over switch 2/1 쮿 Low power consumption 쮿 SMA connectors (others on request) 쮿 Filtered control lines 쮿 Compact dimensions Configuration SPDT Technical data (guaranted values at +25 °C) Frequency range DC to 1000 MHz Isolation 60 dB min. / 65 dB typ. Insertion loss 0,4 dB max. / 0,25 dB typ. VSWR 1,5 : 1 max. / 1,4 : 1 typ. Impedance 50 Ω Maximum RF-power 10 W (cold switching) Switching time 15 ms Life cycles 106 cycles RF-connectors SMA female Options Free-wheeling diode, front panel, latching Model designation Dimensions, serie RU2 RU2 - 5 1 4 2 - S1 Option 3 with front panel Options: 1 = Standard 2 = Free-wheeling diode 3 = Front panel 4 = Latching Power supply: 0 = 5 V DC (50 mA) 1 = 12 V DC (20 mA) 2 = 24 V DC (10 mA) M3/6deep RF-connectors SMA Frequency range DC to 1000 MHz Impedance = 50 Ω M3/6deep RU2 series (change over switch) All dimensions in mm 14 RF-/Video relays DC to 1000 MHz – SPDT-relays Series TVR and T-TVR 쮿 For high resolution monitors and applications at the RF-band 쮿 High isolation 쮿 Low insertion loss 쮿 Impedance optional 50 Ω or 75 Ω 쮿 With BNC connectors (others on request) 쮿 Available at short notice (mostly ex stock Donauwörth) 쮿 Aluminium enclosures (RF shielded) 쮿 Special types on request Technical data (guaranteed values at +25 °C) Configuration SPDT Frequency range DC to 100 MHz DC to 500 MHz DC to 1000 MHz Isolation 70 dB 60 dB 50 dB Insertion loss 0,20 dB 0,30 dB 1,0 dB VSWR 1,2 : 1 1,4 : 1 2,0 : 1 Maximum RF-power* 10 W CW 10 W CW 10 W CW Switching time 15 ms 15 ms 15 ms Life cycles 106 cycles 106 cycles 106 cycles Type A, E, T-TVR A, E, T-TVR A, E, T-TVR Option D The control lines are connected with a 9-pole-SUB-D connector (standard at T-TVR) instead of DC-feedthrough filters. *cold switching Model designation Dimensions, serie TVR and T-TVR T - TVR - 7 2 1 1 - D Option D (only if required) Style A T-TVR Frequency range DC– 1 = 100 MHz 2 = 500 MHz 3 = 1000 MHz Supply voltage 0 = 5 V DC (50 mA) 1 = 12 V DC (20 mA) 2 = 24 V DC (10 mA) Style 0 = A, 2 = E Impedance 5 = 50 Ω, 7 = 75 Ω TVR-series T-TVR-series (Cassette style with front panel) Style E Option D All dimensions in mm Videorelays with switched shield DC to 32 MHz 15 Series TVR-70x9 쮿 RF-relays with switched shield 쮿 For high resolution monitors and applications at the RF-band 쮿 Simultaneously switching of the inner conducter and the shield 쮿 Low insertion loss 쮿 Impedance optional 50 Ω or 75 Ω 쮿 With BNC connectors (floating) 쮿 Available at short notice (mostly ex stock Donauwörth) 쮿 Aluminium enclosures (RF shielded) 쮿 Special types on request Configuration SPDT Technical data (guaranted values at +25 °C) Frequency range DC to 32 MHz Isolation 40 dB Insertion loss 0,2 dB Maximum RF-power 5 W CW (cold switching) Switching time 15 ms RF-connectors BNC, female Option S1 The control lines are connected with a 9-pole-SUB-D connector. Model designation Dimensions, series TVR-70x9-S1 TVR - 7 0 2 9 - S1 Option S1 (prefered type) 9 = change over shield Power supply 0 = 5 V DC (100 mA) 1 = 12 V DC ( 40 mA) 2 = 24 V DC ( 20 mA) Standard style Impedance 5 = 50 Ω, 7 = 75 Ω TVR-series All dimensions in mm 16 RF-/Videorelays DC to 100 MHz – coaxial multi channel relays Series MVR and T-MVR 쮿 DC to 100 MHz 쮿 For simultaneously switching of several independent signals. 쮿 For switching signals between computers and high resolution colour monitors. 쮿 Two until five SPDTs in one unit with only one control line connector. 쮿 Especially applicable for switching of RGB- ,RGBY- and Sync.-signals. 쮿 Impedance 50 Ω or 75 Ω 쮿 BNC connectors (others on request) 쮿 Aluminium enclosures (RF shielded) 쮿 Special types on request Technical data (guaranteed values at +25 °C) Configurations Series MVR T-MVR Frequency range DC to 100 MHz DC to 100 MHz Impedance 50 Ω or 75 Ω 50 Ω or 75 Ω Cross talk 70 dB 70 dB Insertion loss 0,30 dB 0,30 dB VSWR 1,2 : 1 1,5 : 1 Maximum RF-power* 10 W CW 10 W CW Switching time 15 ms 15 ms Life cycles 10 6 cycles 10 6 cycles Configuration / style 2 x SPDT = A4, 4 x SPDT = A8 3 x SPDT = A6, 5 x SPDT = A10 2 x SPDT = A2 3 x SPDT = A3 Option D The control lines are connected with a 9-pole-SUB-D connector instead of DC-feedthrough filters. *cold switching Model designation T - MVR - 7 2 1 1 - D Option D (only on demand) Frequency range 1 = 100 MHz Supply voltage 0 = 5 V DC 1 = 12 V DC 2 = 24 V DC Configuration 2 = 2 x SPDT 3 = 3 x SPDT 4 = 4 x SPDT 5 = 5 x SPDT Impedance 5 = 50 Ω, 7 = 75 Ω MVR-series T-MVR-series (cassette style with front panel) 17 Enclosure dimensions, series MVR and T-MVR Style A4 Style A6 Style A8 Style A10 Style T2 Style T3 Option D All dimensions in mm 18 RF-/Videorelays DC to 32 MHz – coaxial multi channel relays Series UVS and T-UVS 쮿 DC to 32 MHz 쮿 3-way (SP3T) to 8-way (SP8T) 쮿 Impedance optional 50 Ω or 75 Ω 쮿 BNC connectors (others on request) 쮿 Aluminium enclosures (RF shielded) 쮿 Special types on request Technical data (guaranteed values at +25 °C) Configurations Series UVS T-UVS Frequency range DC to 32 MHz DC to 32 MHz Impedance 50 Ω or 75 Ω 50 Ω or 75 Ω Cross talk 55 dB 55 dB Insertion loss 0,20 dB SP3T to SP5T 0,25 dB SP6T to SP8T 0,20 dB SP3T and SP4T VSWR 1,30 : 1 SP3T to SP5T 1,35 : 1 SP6T 1,40 : 1 SP8T 1,30 : 1 SP3T and SP4T Maximum RF-power* 5 W CW 5 W CW Switching time 15 ms 15 ms Life cycles 10 6 cycles 10 6 cycles Configuration / style SP3T = A3, SP4T = A4 SP6T = A6, SP8T = A8 SP3T = A4 SP4T = A4 Option D The control lines are connected with a 9-pole-SUB-D connector (standard at T-UVS) instead of DC-feedthrough filters. *cold switching Model designation T - UVS - 7 3 1 1 - D Option D (only on demand) Frequency range 1 = DC-32 MHz (standard) Supply voltage 0 = 5 V DC 1 = 12 V DC 2 = 24 V DC Configuration 3 = SP3T*, 4 = SP4T* (*T-UVS-series available only to SP4T) 5 = SP5T, 6 = SP6T 8 = SP8T Impedance 5 = 50 Ω, 7 = 75 Ω UVS-series T-UVS-series (cassette style with front panel) 20 Coaxial relay modules with IEEE-488- and RS-232-C-interface Series KRM Cassettes of the type "KRM" can be used to switch various signals and represent a cheap alternative to relay switching units (KRE). The mounted relay is controlled via the IEEE-488- and/or the RS-232-C-interface. The IEEE-488-device-address must be adjusted internally via a DIP-switch. A lower priced alternative is the type which is controlled only via a RS-232-C-interface. A LED at the front panel shows the status of the cassette. Three different standard types of relays are available (others on request). Mostly all the standard types are deliverable at short notice. Enclosure dimensions Desktop unit: W = 105 mm, D = 170 mm, H = 69,7 mm 19“-slot3 HU, 14 TE, cassette: 168,5 mm deep, fitting at standard 19“-frames according to DIN 41 494 Options Mains adaptor 1 A, 12 V Windows-control-software Technical data (guaranteed values at +25 °C) Model SR-6C-H SR-2 MIN-H SR-2-N-H Configuration SP6T (6-way) SPDT (2-way) SPDT (2-way) Frequency range DC-18 GHz DC-18 GHz DC-12,4 GHz RF-connectors SMA female SMA female N female Construction of model designation Isolation (min.) 60 dB min. (18 GHz) 60 dB min. (18 GHz) 55 dB min. (12,4 GHz) KRM 6 - 5 4 1 1 - T Insertion loss (max.) DC – 4 GHz 0,2 dB 4 – 12,4 GHz 0,3 dB 12,4 – 18 GHz 0,5 dB DC – 4 GHz 0,1 dB 4 – 12,4 GHz 0,2 dB 12,4 – 18 GHz 0,3 dB DC – 7 GHz 0,3 dB 7 – 12,4 GHz 0,6 dB VSWR (max.) DC – 4 GHZ 1,25 : 1 4 – 12,4 GHz 1,40 : 1 12,4 – 18 GHz 1,50 : 1 DC – 4 GHz 1,2 : 1 4 – 12,4 GHz 1,3 : 1 12,4 – 18 GHz 1,5 : 1 DC – 7 GHz 1,25 : 1 7 – 12,4 GHz 1,60 : 1 Enlosure style T = desktop unit E = 14 TE-slotcassette Interfaces 1 = IEEE-488 and RS232 2 = RS232 Impedance 50 Ω 50 Ω 50 Ω Switching time 15 ms max. 15 ms max. 20 ms max. Power supply 1 = 12V DC Life cycles 106 cycles 106 cycles 106 cycles Power consumption 530 mA 380 mA 705 mA HF-connectors 4 = SMA female (at SPDT and SP6T) 8 = N female (only at SPDT) Maximum RF-power 35 W CW at 18 GHz 35 W CW at 18 GHz 120 W CW at 12,4 GHz Impedance 5 = 50 Ω Type of switch 2 = SPDT 6 = SP6T KRM-series Power rating 21 Enclosure dimensions, series KRM 14 TE-slot-cassette Controller card BK517 Relays card RS232 Desktop unit Controller card BK517 Relays card RS232 All dimensions in mm 22 Controller cards and interface modules Controller card BK517 for mounting in units The BK517 is presented as a card in Euro-board format. It can be used as a stand-alone unit as well as in combination with additional cards offered from MTS Systemtechnik. The card is based on the microcontroller C517A-LN. The interface is based on the ECB-bus. Generally there are integrated two serial interfaces, 9 x 8 I/O-ports, one IEEE-488-interface and maximal eight analogue inputs. Also available are the interrupt lines 0 - 5. The firmware is stored on a flash module which is plugged on a PLCC-socket. You can use standard 64 K- or 128 K-EPROMs, EEPROMs or FLASH-EPROMs according to the JEDEC-standard as well. It is possible to contact a module for manual operation (e. g. a keyboard and a display or a touchpanel) according to MTS-standards. It is necessary to purchase the firmware from MTS to use the card features. Depending on the configuration of the card, MTS does develop special firmware. The controller card BK517 is able to cope with a heavy workload. MTS uses the card in various units, e. g. relay switching units (KRE). Interface modul RS232/RS485 This card module changes via the RS232- or RS485-interfacing 16 open-collector-outputs. It is available as stand-alone component or as unit in combination with other modules (e. g. relays, attenuators, etc.). Control-software Each output can be controlled manually with a corresponding user interface. T e c h n i c a l d a t a (g ua r a n t e ed v a l u e s a t + 2 5 °C ) Interface Supply voltage RS232, RS485 5 V DC Power consumption 40 mA max. 18 mA typ. Outputs 16 x Open-collector Output current (per output) 500 mA max. Dimensions 57,2 mm x 45 mm (without connectors) Technical data (guaranteed values at +25 °C) Power consumption 130 mA typ. Power supply +5 V DC +5 % – 1 % Dimensions Euro-board format Interface IEEE-488, RS 232 Power amplifiers and small signal amplifiers 23 Series MLV and MKV 쮿 Impedance 50 Ω 쮿 RF-connectors SMA female, others on request Options 쮿 Bias tees 쮿 Application in a 19"unit with power supply and other components. 쮿 Heat sink 쮿 Controllable in combination with adjustable attenuators via IEEE488- or RS232-interface Technical data (guaranteed values at +25 °C) Model Frequency range (MHz) Gain (dB) min. RF-power (out) at –1 dB (dBm) min. Interceptpoint ICP3 (dBm) min. Supply voltage (V DC) Current I (A) max. Noise figure at 25 °C (dB) max. MLV-557-0942-02 1 – 500 40 37 45 28 2,0 7 MLV-647-0976-03 1 – 1000 35 36 (to 750 MHz) 40 35 (to 1000 MHz) 28 2,0 7 MKV-426-5441 8 – 300 8,5 30 35 12 0,6 5 at f>50 MHz MKV-436-5441 8 – 300 20 30 35 12 1,0 5,5 MKV-446-5441 8 – 300 31 30 30 12 1,3 5,5 MKV-626-5441 50 – 1000 8,5 29 28 12 0,6 5 MKV-636-5441 50 – 1000 20 28,5 25 12 1,0 6 MKV-646-5441 50 – 1000 31 28,5 28 (to 600 MHz) 23 (to 1000 MHz) 12 1,3 6 MKV-635-0969-03 100 – 1000 23 17 36 (to 500 MHz) 30 (to 1000 MHz) 15 0,3 3,5 MKV-635-0971 1 – 1000 20 17 30 15 0,25 4,5 MKV-745-0973 100 – 2000 31 11 22 15 0,2 5 MKV-835-0972 50 – 2200 23 12 28 15 0,2 7 Datasheets with detailed specifications can be ordered at MTS. Supply voltage through DC-feedthrough filter (V+) and the ground pin. 24 Resistive signal dividers and power splitters Series RS and PSC 쮿 Splitter with 2 to 6 outputs 쮿 RF-power up to 0,5 Watt CW 쮿 VSWR 1,3 : 1 max 쮿 Linearity max. ±0,5 dB 쮿 RF-connectors: standard BNC, TNC, SMA or other on request The signal dividers of the series RS are resistive dividers which offer very good linearity over the entire frequency range. These dividers can be used also at low frequencies or DC. Isolation and insertion loss depend on the number of outputs. Therefore resistive dividers are suitable for measuring applications. In any case it is important to terminate all inputs and outputs inclusive the unused outputs with the nominal impedance of the splitter. The dividers are generally based on a resistive PI-element and can be used as signal combiners too. Customized signal dividers are available on request (e. g. Y connected dividers with other technical data) (At Y connected dividers each connector can be used as input or output.). Resistive signal dividers Technical data, series RS (guaranteed values at +25 °C) Frequency range DC – 1000 MHz Impedance 50 or 75 Ω VSWR max. 1,3 : 1 Linearity max. ±0,5 dB Maximum RF-power 0,5 W CW Number of outputs 2 3 4 5 6 Isolation 18 dB 24 dB 30 dB 35 dB 40 dB Insertion loss 10 dB 14 dB 17 dB 19 dB 21 dB Splitt./Insertion loss* 6/7 dB 9,6/11 dB 12/13,5 dB – – * only at Y connection (symmetric network) Model designation Power splitter RS - 5 2 0 - S Y-Splitter (only on demand) RF-connectors, female 0 = BNC 2 = TNC 4 = SMA 6 = 1.6/5.6 8=N Number of outputs (2 – 6) Impedance 5 = 50 Ω 7 = 75 Ω RS-series Technical data, series PSC (guaranteed values at +25 °C) Model PSC-2-1-A-BNC PSC-3-1-A-BNC PSC-3-1W-A-BNC Frequency range 0,1 – 400 MHz 1 – 200 MHz 5 – 500 MHz PSC-4-1-A-BNC 0,1 – 200 MHz Outputs 2 3 3 4 Maximum RF-power 1 W CW 1 W CW 1 W CW 1 W CW Isolation 15 dB 25 dB 15 dB 20 dB Insertion loss 3 +1 4,8 +1 4,8 +1,4 6 +1 Impedance 50 Ω 50 Ω 50 Ω 50 Ω RF-connectors (female)* BNC BNC BNC BNC * others on request 25 Enclosure dimensions, series RS and PSC 2-way with N 3-way with BNC 3-way with SMA 2-way with BNC 4-way with BNC 4-way with SMA All dimensions in mm 26 Power splitters, 500 to 2900 MHz Series LT The passive power splitters of the series LT are designed to work at frequency ranges between 500 and 2900 MHz. In this frequency range are for e. g. the tapes from GSM, DECT, UMTS, bluetooth (ISM), etc.. The units can be used as dividers or combiners. 쮿 Divider / combiner 쮿 Application are e. g. GSM, DECT, UMTS, bluetooth 쮿 Other models on request Model designation Technical data (guaranteed values at +25 °C) LT 2 - 5 4 4 P - A2 Frequency range 500 – 2900 MHz At frequency range 800 – 2400 MHz 500 – 2900 MHz Insertion loss 2-way 4-way 8-way 0,3 dB typ. / 0,5 dB max. 0,5 dB typ. / 1,0 dB max. 0,8 dB typ. / 1,5 dB max. 0,5 dB typ. / 1,0 dB max. 0,8 dB typ. / 1,5 dB max. 1,5 dB typ. / 2,5 dB max. RF-connector output 4 = SMA female 8 = N female VSWR IN/OUT 2-way 4-way 8-way 1,3 : 1 typ. / 1,5 : 1 max. 1,3 : 1 typ. / 1,5 : 1 max. 1,5 : 1 typ. / 1,8 : 1 max. 1,5 : 1 typ. / 1,8 : 1 max. 1,5 : 1 typ. / 1,8 : 1 max. 1,5 : 1 typ. / 2,0 : 1 max. RF-connector input 4 = SMA female 8 = N female Isolation 2-way 4-way 8-way 23 dB typ. / 20 dB min. 23 dB typ. / 20 dB min. 20 dB typ. / 18 dB min. 13 dB typ. / 10 dB min. 13 dB typ. / 10 dB min. 11 dB typ. / 9 dB min. Impedance 5 = 50 Ohm Impedance 50 Ω RF-connectors SMA female, N female Number of outputs Temperature range -40 °C to +60 °C LT-series Phase difference at the output 0° Standard P = Passiv Maximum RF-power Splitter: 5 W max. Combiner: 1 W max. per port Enclosure dimensions and possible variations LT2-544P-A2 M2,5/8deep LT2-588P-A2 M2,5/5deep M2,5/5deep All dimensions in mm M3/5deep M3/5deep 27 Enclosure dimensions and possible variations LT4-544P-A2 LT4-588P-A2 M3/5deep M3/5deep M3/5deep M3/5deep LT8-544P-A2 M3/6deep M3/6deep LT8-584P-A2 M3/6deep M3/6deep (at both sites) All dimensions in mm 28 Programmable attenuators DC to 2500 MHz – TTL, RS232, RS485 Series PAS und T-PAS 쮿 DC to 2500 MHz 쮿 Controlling via build in 5-V-TTL-driver or optionally RS232/RS485-interface 쮿 Up to 63 dB total attenuation 쮿 0,5 dB, 1 dB or 2 dB steps (depends on type) 쮿 50 or 75 Ω impedance 쮿 SMA-, BNC-, N-, or TNC connectors 쮿 Also available in cassette enclosures At RF-technology often it is necessary to attenuate a RF-signal defined with a digital control signal. For that applications we offer the types of the series PAS. For the frequency range DC to 2500 MHz switchable attenuators are available with steps of 0,5, 1 or 2 dB. A RS232- or a RS485-interface was integrated to control the units via PC. The controlling is realized via ASCII-strings. The attenuators are available in 50-Ω- and in 75-Ω−technology. Precision relays are used as switching elements in the PAS-series. These relays enable to work up RF-signals with DC voltage parts. RF-connectors are alternatively SMA-, BNC-, N-, or TNC-types (all female). SMB, SMC or other connectors are possible on request. Model designation T - PAS -100 / 31- 5 4 1 1 Style 1 = Standard 2 = Special 3 = RS232 4 = RS485 Supply voltage 0 = 5 V DC 1 = 12 V DC 2 = 24 V DC RF-connectors, female 0 = BNC 2 = TNC 4 = SMA 8=N Impedance 5 = 50 Ω 7 = 75 Ω maximum attenuation Frequency range PAS-series T = only at cassette enclosure Technical data (guaranteed values at +25 °C) Switching time 15 ms Life cycles 106 cycles Operating temperature 0 to +50 °C Maximum RF-power* 0,5 W CW (75 Ω); 1,0 W CW (50 Ω) Impedance 50 Ω or 75 Ω Supply voltage 5, 12, or 24 V (+ 5 V at RS232, RS485) Controlling 5 V TTL (connection via SUB-D connector), RS232, RS485 RF-connectors SMA , BNC , N , TNC female Accessories (optional) Mains adaptor, contol software *cold switching 29 / values ations est! u n e t t u a Other ation on req grad Types and technical data Basic model Frequencyrange (MHz) Attenuation Gradation max. (dB) (dB) Steps of Insertion attenuation loss (dB) (dB) VSWR 0,5 1,3 : 1 Controlling Accuracy per step (dB) 5 bit TTL ±0,3 typ. DC to 100 MHz in 50 Ω and 75 Ω PAS-100/15,5 DC to 100 15,5 0,5-1-2-4-8 1,5 PAS-100/15 DC to 100 15 1-2-4-8 1 1 1,3 : 1 4 bit TTL ±0,3 PAS-100/31 DC to 100 31 1-2-4-8-16 1 1,5 1,3 : 1 5 bit TTL ±0,3 PAS-100/62 DC to 100 62 2-4-8-16-32 2 1,5 1,3 : 1 5 bit TTL ±0,3 PAS-100/63 DC to 100 63 1-2-4-8-16-32 1 2 1,3 : 1 6 bit TTL ±0,3 DC to 1000 MHz in 50 Ω PAS-1000/15,5-5 DC to 1000 15,5 0,5-1-2-4-8 0,5 2,5 1,35 : 1 5 bit TTL ±0,3 PAS-1000/15-5 DC to 1000 15 1-2-4-8 1 2,0 1,35 : 1 4 bit TTL ±0,3 PAS-1000/31-5 DC to 1000 31 1-2-4-8-16 1 2,5 1,35 : 1 5 bit TTL ±0,3 PAS-1000/62-5 DC to 1000 62 2-4-8-16-32 2 3,0 1,35 : 1 5 bit TTL ±0,3 PAS-1000/63-5 DC to 1000 63 1-2-4-8-16-32 1 3,5 1.35 : 1 6 bit TTL ±0,3 PAS-1000/15,5-7 DC to 1000 15,5 0,5-1-2-4-8 0,5 2,5 1,7 : 1 5 bit TTL ±0,3 PAS-1000/15-7 DC to 1000 15 1-2-4-8 1 2,0 1,7 : 1 4 bit TTL ±0,3 PAS-1000/31-7 DC to 1000 31 1-2-4-8-16 1 2,5 1,7 : 1 5 bit TTL ±0,3 PAS-1000/62-7 DC to 1000 62 2-4-8-16-32 2 3,0 1,7 : 1 5 bit TTL ±0,3 PAS-1000/63-7 DC to 1000 63 1-2-4-8-16-32 1 3,5 1,7 : 1 6 bit TTL ±0,3 PAS-2000/15-5 DC to 2000 15 1-2-4-8 1 2,5 1,35 : 1 4 bit TTL ±0,3 PAS-2000/31-5 DC to 2000 31 1-2-4-8-16 1 3,0 1,35 : 1 5 bit TTL ±0,3 PAS-2000/62-5 DC to 2000 62 2-4-8-16-32 2 3,5 1,35 : 1 5 bit TTL ±0,3 PAS-2000/63-5 DC to 2000 63 1-2-4-8-16-32 1 4,0 1,35 : 1 6 bit TTL ±0,3 PAS-2000/15-7 DC to 2000 15 1-2-4-8 1 2,5 2,0 : 1 4 bit TTL ±0,7 PAS-2000/31-7 DC to 2000 31 1-2-4-8-16 1 3,0 2,0 : 1 5 bit TTL ±0,7 PAS-2000/62-7 DC to 2000 62 2-4-8-16-32 2 3,5 2,0 : 1 5 bit TTL ±0,7 PAS-2000/63-7 DC to 2000 63 1-2-4-8-16-32 1 4,0 2,0 : 1 6 bit TTL ±0,7 PAS-2500/15-5 DC to 2500 15 1-2-4-8 1 3,0 1,6 : 1 4 bit TTL ±0,5 PAS-2500/31-5 DC to 2500 31 1-2-4-8-16 1 3,5 1,6 : 1 5 bit TTL ±0,5 PAS-2500/62-5 DC to 2500 62 2-4-8-16-32 2 4,0 1,6 : 1 5 bit TTL ±0,5 PAS-2500/63-5 DC to 2500 63 1-2-4-8-16-32 1 4,5 1,6 : 1 6 bit TTL ±0,5 DC to 1000 MHz in 75 Ω DC to 2000 MHz in 50 Ω DC to 2000 MHz in 75 Ω DC to 2500 MHz in 50 Ω Enclosure dimensions for 4-, 5- and 6-step attenuators Model PAS Model T-PAS Model PAS-RS232 1st gradiation 1st gradiation M2,5/6deep at back side M4/8deep All dimensios in mm Semiconductor attenuators, 200 to 4000 MHz 30 Series PAH The attenuator named PAH-4000/93-5440 is based on semiconductor devices. It is developed for the use between 200 and 4000 MHz. The frequency tapes from GSM, DECT, UMTS, bluetooth (ISM), etc. are in this frequency range. The attenuation of the unit is adjustable continuously and without breaks from 0 to 93 dB. The PAH 4000 can be used very flexible because of its compact style and the controlling via I2C-bus, e. g. with MTS controller card BK 517 or with any PC with the fitting interface. 쮿 Programmable attenuator with I2C-bus-controlling 쮿 Address adjustment via DIP-switch 쮿 Range of application e. g. GSM, DECT, UMTS, TETRA, bluetooth Technical data (guaranteed values at +25 °C) Model PAH-4000/93-5440 General technical data (guaranteed values at +25 °C) Frequency range (MHz) 200 – 500 500 – 800 800 – 3000 3000 – 4000 Insertion loss <5,8 dB <6,1 dB <7,5 dB <8,8 dB Frequency range 200 to 4000 MHz VSWR in/out <2,6 : 1 <2,1 : 1 <1,7 : 1 <1,9 : 1 Impedance 50 Ω Linearity (of Insertion loss) ±0,4 dB ±0,4 dB ±1 dB ±1 dB Attenuation 93 dB max. Gradation 1 / 2 / 4 / 8 /16 / 16 / 16 / 30 dB Maximum RF-power +26 dBm Accuracy of the steps of attenuation 1 – 23 dB 24 – 93 dB ± (0,3 dB + 5% of attenuation value) ± (0,5 dB + 10% of attenuation value) IP 3 +44 dBm typ. RF-connectors SMA female Operating voltage +5 V DC / 10 mA Controlling I2C-Bus Controlling connector Erni blade-contact connector, SMC-12pole Temperature range -10 to +50 C Enclosure dimensions, series PAH SMC-12pole M3 (at both sides) M3/4deep All dimensions in mm Manual adjustable step attenuators 31 Series AS The attenuation of step attenuators series AS is manual selected by toggle switches. Generally the following steps of attenuation are available: 1, 2, 4, 8 (16) dB or 1, 2, 5, 10 (20) dB; MTS offers also other attenuation steps on request. The attenuators are available as 4-step or 5-step types. Model designation AS - 5 0 0 - 4 Number of step (4 or 5) RF-connectors female at the output 0 = BNC 2 = TNC 4 = SMA 6 = 1.6/5.6 8=N RF-connectors female at the input 0 = BNC 2 = TNC 4 = SMA 6 = 1.6/5.6 8=N Technical data (guaranteed values at +25 °C) Basic types Special types AS-5CC4-30-S1 Frequency range DC to 100 MHz 400 to 1000 MHz Attenuation steps 2, 4, 8, 16 dB Impedance 5 = 50 Ω 7 = 75 Ω 1, 2, 4, 8 (16) dB 1, 2, 5, 10 (20) dB Accuracy / step ±0,5 dB ±0,3 dB VSWR 1,3 : 1 1,4 : 1 Series AS Impedance 50 Ω or 75 Ω 50 Ω Maximum RF-power 1 W CW (2 W on request) 0,8 W CW Insertion loss 0,5 dB 0,8 dB RF-connectors BNC, TNC, SMA 1.6/5.6, N female SMC, female Enclosure dimensions, series AS 4 step M2/4deep 5 step AS-5CC4-30-S1 M2/4deep M4/6deep All dimensions in mm 32 Fixed attenuators, DC to 18 GHz Series DGL-18 쮿 Standard types: 3 / 6 / 10 / 20 / 30 dB 쮿 Intermediate values: SMA connectors 0 – 1,75 dB in 0,25 dB-steps 2 – 30 dB in 1 dB-steps 쮿 N connectors 1 – 29 dB in 1 dB-steps Dimensions SMA and N connectors SMA connectors SMA connectors to MIL-C-C-39012 typ. see table N connectors N connectors to MIL-C-39012 typ. Technical data (guaranteed values at +25 °C) Frequency range see table DC – 18 GHz Impedance 50 Ω Peak power 250 W max. (5 µs, 0,05%) Attenuation accuracy VSWR see table 0 – 6 dB ±0,30 dB max. 7 – 20 dB ±0,50 dB max. 21 – 30 dB ±0,75 dB max. DC – 4 GHz 1,15 : 1 max. 4 – 8 GHz 1,20 : 1 max. 8 – 12,4 GHz 1,25 : 1 max. 12,4 – 18 GHz 1,35 : 1 max. Model designation Maximum RF-input power 2 W at 25° C linear decreasing to 0,5 W at 125 °C DGL18 - 5 10 5 4 Temperature range -65 to +125 °C RF-connectors SMA or N RF-connector 1 4 = SMA female RF-connector 2 5 = SMA male Attenuation (dB) 2 digits or Impedance 5 = 50 Ω DGL-series, 18GHz 8=N female 9=N male Dimensions Total length Diameter 0 – 12 dB 13 – 30 dB 0 – 30 dB SMA f / SMA m 7,10 mm 22 mm 25 mm – SMA m / SMA m 7,10 mm 25 mm 28 mm – SMA f / SMA f 7,10 mm 22 mm 25 mm – Nf/Nm 15,75 mm – – 44,70 mm Nm/Nm 14,22 mm – – 46,23 mm Nf/Nf 14,22 mm – – 50,42 mm to 60 nectors up With N con est dB on requ Fixed attenuators, DC to 1000 MHz 33 Series DGL In the series DGL we offer fixed attenuators combined with all saleable coaxial connectors (jack or plug). The operator doesn´t need expensive adapters and prevents measuring errors as result of bad impedance matching between the adapter and the attenuator. The coaxial attenuator series DGL is designed to meet specifications within a frequency range from DC to 1000 MHz. Some models are designed for single hole front panel mounting. Various types are available with standard attenuation values of 1 dB, 3 dB, 6 dB, 10 dB or 20 dB ex stock in Donauwörth. For intermediate values or higher power contact your representative! Enclosure dimensions, series DGL Technical data (guaranteed values at +25 °C) Frequency range DC to 1000 MHz Impedance 50 Ω or 75 Ω Attenuation 1 dB to 30 dB in 1 dB-steps Accuracy of attenuation ±0,5 dB to 20 dB; ±0,7 dB from 20 dB VSWR 1,25 : 1 Maximum RF-power (bidirectional) 0,5 W CW (25 °C) (others on request) Temperature range -25 to +85 °C Dimensions see also series DGL, IAG, DCB Model designation DGL - 5 10 1 0 RF-connector 2 RF-connector 1 Attenuation (dB) 2 digits Impedance: 5 = 50 Ω 7 = 75 Ω DGL-series All dimensions in mm 0 1 2 3 4 6 7 8 9 = = = = = = = = = BNC female BNC male TNC female* TNC male* SMA female* 1.6/5.6 female** 1.6/5.6 male** N female N male A = SMB female* B = SMB male* C = SMC female* D = SMC male* E = SMS female* F = SMS male* * only 50 Ω, ** only 75 Ω 33 34 Impedance matching modules / DC-blocks Impedance matching modules, series IAG request! uencies on Other freq An impedance matching module is used for measurement applications or for coupling modules with unequal impedance. Technical data (guaranteed values at +25 °C) Frequency range DC to 2 GHz Impedance 50 Ω and 75 Ω Insertion loss 6,5 dB VSWR 1,5 : 1 Maximum RF-power 0,5 W CW (25 °C) (others on request) Temperature range -25 to +85 °C Dimensions see styles of the series DGL, IAG, DCB Standard connectors N/N and BNC/BNC, also see styles and dimensions of the series DGL, DA/DAS, IAG, DCB Model designation IAG 0 - 50 - 0 - 75 Impedance 75 Ω RF-connector 75 Ω Impedance 50 Ω RF-connector 50 Ω IAG-series 0 1 2 3 4 6 7 8 9 = = = = = = = = = BNC female BNC male TNC female* TNC male* SMA female* 1.6/5.6 female** 1.6/5.6 male** N female N male A B C D E F = = = = = = SMB female* SMB male* SMC female* SMC male* SMS female* SMS male* *only 50 Ω, ** only 75 Ω DC-block, 50 MHz to 2 GHz, series DCB request! uencies on Other freq A DC-block prevents following components from DC-voltages. Technical data (guaranteed values at 25° C) Frequency range 50 MHz to 2 GHz Impedance 50 Ω (75 Ω on request) Insertion loss 2 dB typ. VSWR 1,25 : 1 Maximum RF-power 0,5 W CW (25° C) (others on request) Temperature range -25 °C to +85 °C Standard connctors N, BNC, TNC, also see styles and dimensions of the series DGL, IAG, DCB Construction of model designation DCB - 5 0 0 - 2G Standard frequency HF-connector 2 HF-connector 1 Impedance 5 = 50 Ω 7 = 75 Ω DCB-series 0 1 2 3 4 6 7 8 9 = = = = = = = = = BNC female BNC male TNC female* TNC male* SMA female* 1.6/5.6 male** 1.6/5.6 male** N female N male A = B = C = D = E = F = SMB female* SMB male* SMC female* SMC male* SMS female* SMS male* *only 50 Ω, ** only 75 Ω 35 Style and dimensions of the series DGL, IAG, DCB BNC-f/m BNC-f/f TNC-f/m TNC-f/f N-f/m N-f/f 1.6/5.6-f/m 1.6/5.6-f/f SMA-f/f SMA-f/m SMC-m/m All dimensios in mm 38 Aircirculation ventilation units Series LE-U 쮿 230 V, 50/60 Hz AC voltage 쮿 12 V DC voltage 쮿 24 V DC voltage Generally our aircirculation ventilation units are made as 19"units from a height of 1HU (1 HU = 43,6 mm). The customer can choose between 1, 2 or 3 raws of ventilators in the depth. We offer the 230 V AC units with the types of ventilators named A, B or C, the 12 V DC versions with the types named D or E and the 24 V DC versions with the types F or G (see page 41). The ventilation units series LE are open at the bottom side. We can offer finger protectors or dust filters for bottom side on request (Finger protectors and dust filters are not available for fan type C). 쮿 Other heights (2HU, 3HU) or other depths on request; Air flow direction Air is sucked from below and is led onto the upper side. Typical applications 쮿 Support of natural convection inside of 19"racks 쮿 Forced air cooling of equipment by means of air circulation ered! consid e b l il hes w er´s wis Custom Basic configuration Options and accessories 쮿 Front panel is colourless anodized. 쮿 Rubber socket and cable, 2 m long (230 V AC voltage) 쮿 19"unit is yellow alodyned. 쮿 Rubber connector for 230 V AC includes switch and fuse (power cord is not included with 230 V AC types.). (= Option 1) 쮿 Rubber socket and cable, 3 m long (230 V AC voltage) (= Option 2) 쮿 Extra dust filter for 1-raw drawer (= Option 3) 쮿 12 V DC or 24 V DC types are delivered with 1,2 m cable inclusive pull relief. 쮿 Take off of hot air by mounting the blowers at the top of a unit 쮿 The number, the model and the position of fans can be specified on demand. 쮿 Elimination of heat sections in a rack 쮿 Unused positions will be closed with a blank plate. 쮿 Please send us your application! 쮿 Extra dust filter for 2-raw drawer (= Option 4) 쮿 Extra dust filter for 3-raw drawer (= Option 5) 쮿 Finger protection at bottom side (= Option 6) 쮿 Custom silk-screen printing on the front panel (= Option 7) Examples of special custom models Model LE1-1520-09, 1 HU ventilation unit, 2 fans, TTL alarm circuit for protection of external equipment Model LE1-3531-15C, 1 HU ventilation unit, 3-6 fans according to customers request Model LE2-3E-11, 2 HU ventilation unit, 3 fans and 3 mains outlets Front sucking ventilation units 39 Serie LE-F 쮿 230 V, 50/60 Hz AC voltage 쮿 12 V DC voltage 쮿 24 V DC voltage The front sucking ventilation units are available with 2 HU front panels (2 HU = 88 mm). The customer can select between 1, 2 or 3 raws of ventilators in the depth. We offer the 230 V AC units with the types of ventilators named A, B or C, the 12 V DC versions with the types named D or E and the 24 V DC versions with the types F or G (see page 41). The exact ordering designation is described at page 40. Generally the front sucking ventilation units are equipped with a large dust filter at the side of the air suction. This dust filter is mounted horizontally below the fans. With this construction you reach a homogeneous contamination and a very long life cycle of the filter. Air flow direction The unit sucks in the air at its front side, filters it and blows it upwards. Typical applications 쮿 Ventilating the whole rack from the bottom to the top 쮿 Forced cooling of several units with air from outside the rack. 쮿 Elimination of heat sections within an unit, especially if there is no possibility to use aircirculation ventilation units. red! onside c e b l hes wil er´s wis m o t s u C Options and accessories 쮿 Rubber socket and cable, 2 m long (230 V AC voltage) (= Option 1) 쮿 Rubber socket and cable, 3 m long (230 V AC voltage) (= Option 2) 쮿 Extra dust filter for 1-raw unit (= Option 3) 쮿 Extra dust filter for 2-raw unit (= Option 4) 쮿 Extra dust filter for 3-raw unit (= Option 5) 쮿 Custom silk-screen printing on the front panel (= Option 7) Aircirculation ventilation units Front sucking ventilation units Basic configuration 쮿 Front panel is colourless anodized. 쮿 19"unit is yellow alodyned. 쮿 Rubber connector for 230 V AC includes switch and fuse (power cord is not comprised with 230 V AC types.). 쮿 12 V DC or 24 V DC types are delivered with 1,2 m cable inclusive pull relief. 쮿 Dust filter 쮿 The number, the model and the position of fans can be specified on demand. 쮿 Unused positions will be closed with a blank plate. The air is sucked below the ventilation unit and is conveyed to the top. The air is sucked through the frontside of the ventilation unit, filtered and conveyed to the top. Ventilation units, ordering information 40 Series LE-U and LE-F Please choose the needed parts of the ordering number of a special ventilation unit from the following drawings. Aircirculation ventilation units are available only with a height of 1HU, front sucking ventilation units with a height of 2HU. 1-raw ventilation unit The front panel width of all models is 19" (482,6 mm). 2-raw ventilation unit 3-raw ventilation unit 1HU, aircirculating, model U1 1 HU, air, Modell U1 43,6 1HU, model 1 H,aircirculating, umlüftend, Modell U2U2 43,6 1HU, 1 aircirculating, model U3 43,6 22HU, HE, frontansaugend, ModellF1 F1 front sucking, model 88 front sucking, model 22HU, HE, frontansaugend, ModellF2 F2 88 front sucking, model 22HU, HE, frontansaugend, ModellF3 F3 88 1 2 3 171 431,5 mm 4 5 6 311 1 2 3 All dimensions in mm. Model designation LE - U1 - A - 0 - 3 - 1/2/3 Position of fans (not necessary if all positions are used) No. of fans installed (not necessary if all positions are used) Options 0 1–7 Supply voltage A, B, C of the type of fan D, E F, G H = No option (standard) = See description of the relevant ventilation unit = = = = 230 V AC 12 V DC 24 V DC 48 V DC Model selection U1 to U3 = Aircirculating F1 to F3 = Front sucking Basic model description Air conveying direction 431,5 mm Air conveying direction Air conveying direction 431,5 mm 7 8 9 4 5 6 1 2 3 451 mm DC-feedthroughs, DC-feedthrough filters 42 Series D/DF DC-feedthroughs We offer various models of teflon isolated DC-feedthroughs. Type D1 and D2 are delivered without nut and toothed lock washer. Model D1 M3.5, item no. 46.13.0016 Inner conductor gold-plated Model D2 M5 x 0,5, item no. 46.13.0017 Inner conductor gold-plated DC-feedthrough filters DC-feedthrough filters prevent the power supply path from transporting RF-signals in or out of an enclosure. Technical data DC-feedthrough filters Type max. voltage (at +85° C) max. current min. capacity pF min. no load insertion loss at 25°C to MIL-STD-220 10 MHz 100 MHz 1 GHz 10 GHz item no. DF2 350 V DC 10 A 1500 5 dB 45 dB 70 dB 70 dB 46.13.0014 DF3 200 V DC 10 A 1500 5 dB 45 dB 65 dB 70 dB 46.13.0013 Typical attenuation DC-feedthrough filters Dimensions DC-feedthroughs and DC-feedthrough filters Insertion loss in dB Supplied with nut and washer, detailed technical data sheets are available on request. Model D1 Model D2 Model DF2 Model DF3 Frequency in MHz All dimensions in mm Information (other components / feedback) 43 request! Available on Variable attenuators – adjustable continuously, series DGV Frequency range Attenuation Impedance Max. RF-power RF-connectors DC to 1000 MHz 18 dB min., 20 dB typ. 50 Ω or 75 Ω 1W SMA female Manual coaxial switches, series SW Frequency range Impedance Max. Rf-power RF-connectors DC to 32 MHz 50 Ω or 75 Ω 5 W CW SMA, BNC, N or TNC female Power attenuators, series LDGL and power terminations, series LAW Coaxial terminations, series AW and coaxial short circuits, series KK Frequency range DC to 2 GHz Impedance 50 Ω Max. RF-power LDGL 10 W or 50 W LAW 10 W or 60 W RF-connectors SMA, BNC, N, TNC Frequency range Impedance Max. RF-power RF-connectors Feedthrough terminations, series DA/DAS Bias tees, series FSW Frequency range Impedance RF-connectors Frequency range Impedance RF-connectors DC to 500 MHz 50 Ω or 75 Ω BNC 50 MHz to 2 GHz 50 Ω BNC, SMA, TNC, N fax o t n r u t Re Copy this page, fill it out and send it back to MTS Systemtechnik. Please don´t forget your address! 쑽 1 6 6 6 / 6 090 Company Name DC to 1000 MHz 50 Ω or 75 Ω 1 W CW BNC, SMA, TNC, 1.6/5.6, N Dpt. Street Post code Location Phone Telefax Systemtechnik RF-systems and -units Data technology E-Mail About the selected products please Mechanical products 왏 send me detailed information Systems and units 왏 Signal distribution units 왏 Antenna distrib. units / multi couplers 왏 Combiners 왏 Remote controlled switching units 왏 Filter units 왏 Ventilation units 왏 Matrices 왏 Coupling units 왏 Air interface adapters 왏 Shielding boxes Components 왏 Coaxial relays 왏 Multi channel switches 왏 Videorelays 왏 Feedthrough terminations 왏 DC-blocks 왏 Fixed attenuators 왏 Terminations 왏 Coaxial short circuits 왏 Power attenuators and power terminations 왏 send me an offer 왏 Signal dividers, power splitters, combiners and multi couplers 왏 Programmable step attenuators 왏 Coaxial cable assemblies 왏 Bias tees 왏 Directional couplers 왏 Impedance matching modules 왏 PC controlled components 왏 Amplifiers Mechanical modules 왏 RF shielded enclosures 왏 Structural enclosures 왏 Custom specified enclosures 왏 Milled components 왏 Milled cassettes 왏 Cassette enclosures 왏 19"-racks 왏 Ventilation units 왏 call me back Data technology 왏 Controller cards and accessories for operators in electronic 왏 Control units 왏 Custom specified interface units 왏 Development of firm- and software according to customer's wishes 왏 Services 왏 CAD development and customerspecified CNC milled modules 왏 Mounting of components to and testing of RF printed circuit boards 왏 Engineering-service 왏 Programming-service Distribution for IMS Connector-Systems GmbH 왏 Coaxial connectors 왏 Terminations 왏 Coaxial adapters 왏 Coaxial cable assemblies Overview of systems and instruments 46 Systems and instruments Signal distribution units for 쮿 Video signals 쮿 LF, HF, VHF, UHF 쮿 Data signals / control units PC controlled signal switching units 쮿 With standard relays 쮿 Customer-specified (for measurement usage) 쮿 With control software for windows Matrices for 쮿 쮿 쮿 쮿 쮿 Audio signals Video signals LF, HF, VHF, UHF Satellite communication Microwave applications Filter units Satellite communication in Coupling units 쮿 L-, C-, X-, Ku- frequency band Air Interface adapter Professional systems for telekommunication, e. g. Shielding boxes 쮿 simulated hops testing GSM-modules within 쮿 For repeater defined environmental influences 쮿 Mastheads 쮿 Possibility coupling units of operating the test modules 쮿 during air-interface adapter the test with remote control Aluminium cover (closed) and further cover Shielding boxes with shielded wire mesh to operate the 쮿 test for testing GSM-modules speciem manually (bywith closed box) defined environmental influences 쮿 shielding around 80 dB (under defined conditions, order data sheed) 쮿 s Please send u your inquiry! Mechanical overview RF shielded enclosures 쮿 Series AG/AGO RF shielded enclosures for electronicand RF-applications (PCB clamp mounted) 쮿 Series UC RF shielded enclosures with variable bearing surface for PCBs (PCB screw mounted) 쮿 Series ZG RF shielded enclosures for hybrid applications, dimensions in inches 쮿 Series TC RF shielded enclosures for mounting of TO8-thin and thick-film modules Structural enclosures 쮿 Series G Structural enclosures made of rectangular tubes with variable base plate and cover 쮿 Series KG Customized structural enclosures (width, depth), available optionally in heights of 1 HU, 2 HU, 3 HU or 4HU 19’’-technology 쮿 Series FK RF shielded milled cassettes for units according to DIN 41494/T5, Euro-board format (inside and outside!) 쮿 Series HK RF shielded structural cassettes for plug-in units according to DIN 41494/T5, depth like an Euro-board or customized 쮿 19’’-plug-in units 19’’-chassis (empty) and 19’’-subracks also with improved RF shielding 쮿 Milled components Customized milled components s Please send u your inquiry! 47