BEGA Installation and Technical Information 3222MH Surface wall - up/down lighting with single spike Tools Requir ed: Required: 8mm nut driver 3mm hex key Philips medium screwdriver Medium slotted screwdriver Dimensions A A: 5-7/8 " B: 8-1/4 " B UL listed, suitable for wet locations. Pr otection Class: IP65 Protection Weight: 6.5 lbs. Notice to Installer for 3222MH: 1. For wall applications only. 2. Mounts directly to standard recessed 4” octagonal wiring box (by others), using mounting kit (supplied). 3. In conformance with UL Standard 1598, a silicone based sealant must be used between luminaire and supporting wall. 4. For properly aligned light distribution on both sides, make sure the lamp is centered in the lampholder. 3222MH - installation: 1. Loosen (2) 3mm set screws on outer casting and remove outer casting. 2. Loosen (2) screws near lampholder and turn lampholder plate counterclockwise to remove from base. 3. Install (2) long 8-32 x 1 1/2” mounting screws (provided) in the back of the adapter plate as shown. 4. Attach adapter plate to wiring box using (2) 8-32 x 1/2” screws provided. Feed luminaire wires through luminaire base and adapter plate. 5. Make supply wiring and luminaire wiring connections in the octagonal wiring box: MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE 3220.538.indd 177 GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE 6. Place a small bead of silicone around the back side of the luminaire base that will come in contact with the finished wall (exterior applications only). 7. Attach luminaire base to adapter plate over the mounting screws using the (2) acorn nuts provided in the mounting kit. Tighten the nuts to back the screws into the wiring box and secure the plate to the box. 8. Replace lampholder plate onto luminaire base over (2) plate screws. Turn clockwise and tighten screws evenly to secure. TANT 9. Insert lamp (by others). IMPOR IMPORT ANT:: BE SURE LAMP IS CENTERED IN LAMPHOLDER (Fig 2). 10. Replace outer casting and tighten (2) set screws, making sure that the gasket TANT is seated properly. IMPOR IMPORT ANT:: BE CAREFUL NOT TO DISRUPT LAMP POSITION WHEN INST ALLING CASTING OVER LAMP ONTO LUMINAIRE BASE INSTALLING (Fig 3). Relamping/Mainten ance Relamping/Maintenance Loosen (2) set screws and remove outer casting. Relamp. Clean luminaire and lens using only solvent-free cleansers. Replace casting and tighten set screws, making sure that the gasket is seated properly. Lamp: Fig 1 3-1/2 or 4 standard octagonal wiring box (by others) mounting plate or luminaire base adapter plate wiring box screws mounting screws Fig 2 NOTE: Make sur e lamp position is center ed ver tically sure centered vertically and horizontally on lampholder Fig 3 Acc essories Accessories Please refer to the appropriate accessory installation sheet for further instruction when applicable. NOTE: Car efully slide Carefully casting over lamp without moving lamp out of center ed centered position Replacement Par ts Parts Description Part No Lens Lens gasket 3x Lampholder Ballast (120V-277V) 112583.2 830594 74142 75230 (1) 39W T4 G8.5 MH Philips : CDM35/TC Osram/Sylvania : MC39TC/U/G8.5 GE : CMH39/TC/U/G8.5 In the interest of product improvement, BEGA reserves the right to make technical changes without notice. BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2010 3222MH 4/5/2010