IS 3222MH

advertisement
BEGA
Installation and Technical Information
3222MH
Surface wall - up/down lighting with single spike
Tools Requir
ed:
Required:
8mm nut driver
3mm hex key
Philips medium screwdriver
Medium slotted screwdriver
Dimensions
A
A:
5-7/8 "
B:
8-1/4 "
B
UL listed, suitable for wet locations.
Pr
otection Class: IP65
Protection
Weight: 6.5 lbs.
Notice to Installer for 3222MH:
1. For wall applications only.
2. Mounts directly to standard recessed 4” octagonal wiring box (by others),
using mounting kit (supplied).
3. In conformance with UL Standard 1598, a silicone based sealant must be used
between luminaire and supporting wall.
4. For properly aligned light distribution on both sides, make sure the lamp is
centered in the lampholder.
3222MH - installation:
1. Loosen (2) 3mm set screws on outer casting and remove outer casting.
2. Loosen (2) screws near lampholder and turn lampholder plate counterclockwise to remove from base.
3. Install (2) long 8-32 x 1 1/2” mounting screws (provided) in the back of the
adapter plate as shown.
4. Attach adapter plate to wiring box using (2) 8-32 x 1/2” screws provided. Feed
luminaire wires through luminaire base and adapter plate.
5. Make supply wiring and luminaire wiring connections in the octagonal wiring
box:
MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE
NEUTRAL
(COMMON) SUPPLY WIRE TO WHITE LUMINAIRE WIRE
3220.538.indd
177
GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE
6. Place a small bead of silicone around the back side of the luminaire base that
will come in contact with the finished wall (exterior applications only).
7. Attach luminaire base to adapter plate over the mounting screws using the (2)
acorn nuts provided in the mounting kit. Tighten the nuts to back the screws into
the wiring box and secure the plate to the box.
8. Replace lampholder plate onto luminaire base over (2) plate screws. Turn
clockwise and tighten screws evenly to secure.
TANT
9. Insert lamp (by others). IMPOR
IMPORT
ANT:: BE SURE LAMP IS CENTERED IN
LAMPHOLDER (Fig 2).
10. Replace outer casting and tighten (2) set screws, making sure that the gasket
TANT
is seated properly. IMPOR
IMPORT
ANT:: BE CAREFUL NOT TO DISRUPT LAMP
POSITION WHEN INST
ALLING CASTING OVER LAMP ONTO LUMINAIRE BASE
INSTALLING
(Fig 3).
Relamping/Mainten
ance
Relamping/Maintenance
Loosen (2) set screws and remove outer casting.
Relamp. Clean luminaire and lens using only
solvent-free cleansers. Replace casting and tighten
set screws, making sure that the gasket is seated
properly.
Lamp:
Fig 1
3-1/2” or 4”
standard
octagonal
wiring box
(by others)
mounting
plate or
luminaire
base
adapter
plate
wiring
box
screws
mounting screws
Fig 2
NOTE: Make sur
e lamp position is center
ed ver
tically
sure
centered
vertically
and horizontally on lampholder
Fig 3
Acc
essories
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
NOTE: Car
efully slide
Carefully
casting over lamp
without moving lamp
out of center
ed
centered
position
Replacement Par
ts
Parts
Description
Part No
Lens
Lens gasket 3x
Lampholder
Ballast (120V-277V)
112583.2
830594
74142
75230
(1) 39W T4 G8.5 MH
Philips :
CDM35/TC
Osram/Sylvania :
MC39TC/U/G8.5
GE :
CMH39/TC/U/G8.5
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2010
3222MH
4/5/2010