Panelboards and Lighting Control

advertisement
Panelboards and Lighting Control
Pow-R-Command
10.6
Contents
Pow-R-Command Family
Description
Page
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
451
453
454
457
460
463
467
470
473
10
10
10
10
10
10
10
An Eaton
Green Solution
10
10
10
10
Product Overview
Eaton’s Pow-R-Command™
family of lighting control
panelboards is designed to
meet the lighting control
needs for buildings of all sizes
and complexity. The system
incorporates microprocessorbased distributed intelligence
within a traditional
panelboard, simplifying wiring
in the field. The system can
be networked over
customers’ LAN or directly
interfaced to the Internet,
allowing for password
protected web access. The
panelboard design allows the
Pow-R-Command lighting
control system to meet shortcircuit ratings, as required by
the National Electrical Code
(NEC). The Pow-R-Command
panelboard mounting, power
wiring and branch wiring are
the same as in traditional
panelboards. Depending on
the controller model, PRC
controllers can be applied to
distribution systems rated
single-phase three-wire
and three-phase four-wire
120, 120/240, 208Y/120 and
480Y/277 Vac. The PRC
family consists of the
PRC2000, PRC1000,
PRC750, PRCEP, PRC100,
PRC50 and the PRC25 for
panelboard installations and
the PRC4000 building control
devices, which have wireless
communications.
Lighting Control Overview
Traditional lighting control
employs lighting contactors
or relay panels to turn groups
of lighting on or off. Input
devices are typically time
clocks, photo cells, wall
switches, or, in more
sophisticated applications,
contact inputs from a building
automation system (BAS).
Pow-R-Command is a lighting
control panelboard with
remote controllable circuit
breakers. These controllable
circuit breakers perform a
dual function:
1. They provide the
overcurrent and overload
protection for the circuit.
2. They perform the same
function as relays and
contactors in traditional
lighting control systems,
opening and closing the
circuit in response to a
remote signal.
Design Considerations
Short-Circuit Protection: In
the past, contactors or relay
panels were mounted close
to the lighting load and shortcircuit ratings were not a
major concern. Today, most
of the lighting control devices
are located in electrical
rooms, often adjacent to the
panelboards that feed them.
These devices are subjected
to short-circuit conditions
almost as high as those of
the electrical distribution
equipment. The current
version of the National
Electrical Code requires that
these lighting control devices
carry a short-circuit rating
(Article 110-10). Although
some traditional lighting
control components are
available with short-circuit
ratings, these ratings are
limited and may require
upstream fusing. A lighting
control panelboard makes
meeting the requirements of
NEC 110-10 as simple as
specifying the short-circuit
rating of the panelboard.
Retrofit Applications:
Retrofitting traditional lighting
control methods into an
existing electrical distribution
system often requires
extensive rewiring and
unwanted downtime. In most
cases, a Pow-R-Command
panel interior can be installed
into an existing panelboard
back box, and the cables can
be re-terminated on the new
circuit breakers, with minimal
downtime.
10
10
10
10
10
10
10
10
Flexibility: Lighting control
panelboards allow simple and
inexpensive changes during
startup. Contactor and relay
panels often require rewiring
to make changes in the field.
10
10
10
Choices: Eaton’s lighting
control panelboards offer
varying levels of flexibility,
from six zones per panel with
the Pow-R-Command 25 up
to 250 zones per panel with
the Pow-R-Command 2000.
10
10
10
Space: Lighting control
panelboards eliminate
contactor panels and/or relay
panels, freeing up valuable
wall space. Pow-R-Command
panels are the same width as
standard panelboards.
Volume 2—Commercial Distribution CA08100003E—December 2010
10
10
10
10
10
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
447
10.6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Panelboards and Lighting Control
Pow-R-Command
Installation Considerations
Simplicity: Lighting control
panelboards are as easy to
install as standard
panelboards. There are no
additional components to
install.
Labor: Because contactors
and relays are eliminated, the
labor associated with
installing them and the
additional cables and conduit
associated with them is
eliminated.
Startup: Startup for the PowR-Command panelboards is
straightforward. The PRC25
requires no startup. It is
prewired at the factory. The
PRC100 is provided with
factory startup assistance for
trouble-free installation. The
PRC750 is provided with an
LCD display and keypad for
on-site programming. The
PRC1000 and PRC2000 are
programmed over the
network. They have an
optional display available for
local interface.
Operational Considerations
Failure Modes: If a lighting
contactor or relay fails to
operate due to a mechanical or
control system failure, it is
very difficult to control the
lights manually. Often, it is
necessary to hard-wire
around the device on a
temporary basis. With a
lighting control panelboard
system, the circuit breaker
can be manually switched on
or off as necessary until the
system is back in operation.
Flexibility: In many cases,
the lighting control scheme
may change over the life of
the facility. With traditional
lighting control methods,
changes require major
rewiring and facility
downtime. Breaker control
schemes can be changed
within the lighting control
panelboard, often with a
simple modification through
software.
10
10
10
448
Pow-R-Command 4000
(PRC4000)
The Power-R-Command 4000
wireless lighting control
system is a robust wireless
communication system that
can be utilized in new and
retrofit applications. The
wireless system components
consist of the Pow-RCommand 4000 (PRC4000)
controller, the Pow-RCommand Wireless I/O
Module (PRCWIOM) and the
Pow-R-Command Wireless
Switch (PRCWS). It has a
multitude of advanced
features that perform the
seamless control of every
zone in your entire facility, as
well as complex energymanagement tasks. Basic
programming of the PRC4000
is done through a standard
Web page interface including
the scheduling, status and
override.
Pow-R-Command 2000
(PRC2000)
Eaton’s PRC2000 is a
microprocessor-based
programmable lighting
control system that can be
used to control all of the
lighting in your industrial
facilities, high-rise office
buildings and airports. Being
on the cutting edge of
technology, the Pow-RCommand 2000 is an IPbased device with an
embedded Web server.
Capable of being utilized in
both standalone and
networkable applications, the
PRC2000 can incorporate
both standard branch
mounted breakers and
controllable thermal-magnetic
breakers for tailored control.
The System Controller also
includes load override,
holiday scheduling, one-shot
or event schedules, off
warning to tenants, memory
loss protection, hardware
diagnostics and real-time
clock for optimal energy
management functions. The
PRC2000 also incorporates
the ability to communicate
with networked devices over
the Building Automation and
Control Network (BACnet®)
protocol. BACnet is an
industry standard protocol
and provides increased
flexibility in component and
device selection for the
control system.
Pow-R-Command 1000
(PRC1000)
Eaton’s PRC1000 is a
microprocessor-based
programmable lighting
control system. With ratings
from 100–225A, the
PRC1000 can be used as a
standalone panelboard or
networked as a system. The
panelboard utilizes both
branch mounted standard
breakers through 100A, and
controllable thermal-magnetic
breakers controlled by the
Pow-R-Command 1000
System Controller. The
System Controller also
includes load override,
holiday scheduling, one-shot
or event schedules, off
warning to tenants, memory
loss protection, hardware
diagnostics and real-time
clock for optimal energy
management functions. The
PRC1000 system contains
networkable intelligence and
provides automated
switching of branch circuit
breakers.
Advanced Control Devices
The PRC2000 and PRC1000
controller has an onboard
Digital Switch Network (DSN)
that provides interaction with
the Pow-R-Command Digital
Switches. The Pow-RCommand Digital Switch
(PRCDS) is a state-of-the-art
microprocessor-based low
voltage device. Each PRCDS
is completely customizable
and can be programmed to
meet the needs of the
customer’s lighting control
strategy. This programming is
stored directly in the switch’s
integrated memory, which
adds to the reliability of the
digital switch network. Each
switch has the ability to
communicate directly to a
PRC1000 or PRC2000 lighting
controller through a dedicated
switch network. In addition to
its network communication
capabilities, the PRCDS has
built-in inputs and outputs
that allow the connection of
photo sensors, occupancy
sensors and dimmable
Volume 2—Commercial Distribution CA08100003E—December 2010
ballasts to achieve a fully
integrated zone lighting
control from one device. Each
PRC controller can have up to
99 digital switches connected
to its DSN using CAT6 cable.
This gives distributed control
throughout the entire facility
at a much lower cost of
installation. In addition, there
is local feedback through a
status LED illuminated in
each button on the switch.
The Pow-R-Command Low
Voltage Switch (PRCLS) is a
momentary dry contact
switch that is used for inputs
into the Pow-R-Command
controllers. This simple
switch does not need a
power supply; it is connected
directly between the digital or
universal inputs and its
common of the PRC
controller. This provides the
ability to have up to six
individual switches in one
standard switch location.
Both the PRCDS and PRCLS
are offered in three
configurations, a 2-button, 4button or 6-button. In
addition, each configuration is
offered in three colors, Black,
White or Almond.
Pow-R-Command 750
(PRC750)
Designed for standalone
applications, Eaton’s PRC750
is a premier microprocessorbased lighting control system
that can be used to control all
of the lighting in your
industrial facilities, high-rise
office buildings and airports.
A single PRC750 panelboard
can be connected to a
maximum of three expansion
panelboards for the ability to
control up to a total of 168
Smart Breakers™. The
PRC750 also boasts load
override, holiday scheduling,
memory loss protection,
astronomical time clocks and
scheduling, 16 switch inputs,
and alarm and message log
features.
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
Pow-R-Command Expansion
Panelboard (PRCEP)
The PRCEP is a slave
panelboard designed to work
in conjunction with the
PRC750, PRC1000 and
PRC2000 controller. The
PRCEP is configured the
same as a standard
panelboard, but has PRC
Breaker Control Bus (BCB)
units installed that
communicate to the PRC
controller. To aid in cost
reduction in some
applications, there can be
controllable and standard
breakers installed in the
panelboard, and the
panelboard can be configured
with a BCB on the left, the
right or on both sides of the
panelboard for a more
custom solution. The PRC
controller has the ability to
control up to eight BCBs in
any of the various PRCEP
configurations. The PRCEP
breaker compatibility is the
same as the PRC controller
panelboards and the layout
and sizing rules are the same
as a standard 1A/2A
panelboard.
Pow-R-Command 100
(PRC100)
Eaton’s PRC100 panelboard
system offers the broadest
range of energy control in the
industry using standalone
PRC100 panelboards or a
network of PRC100
panelboards. The PRC100
system is ideal for large,
medium and small facilities
with lighting control systems
that require frequent changes,
networkable panelboards,
remote access, or all of the
above. There are applicationspecific controllers available
such as the native Johnson
Controls® Metasys® (JCI)
and the native Modbus®
controllers. Examples
may include stadiums,
auditoriums and theatres,
office buildings, large
retailers and schools.
Pow-R-Command 50 (PRC50)
The PRC50 panelboard is a
PRC100 panelboard with
additional programming
capability added that provides
the ability to group up to 42
remotely operated circuit
breakers into 8 individual
zones. Each zone is designed
to be switched by a dry
contact from an external time
clock, switch or Interposing
relay.
The PRC50 programming
board included with the
controller allows the breakers
to be grouped locally without
the need of special
equipment or software. The
groupings can be easily
changed without the need of
any field rewiring. The
grouping configurations are
made using simple
pushbutton inputs.
The panelboards are available
with a full line of ratings and
accessories.
Pow-R-Command 25 (PRC25)
Eaton’s PRC25 Panelboard
replaces contactors and relay
panels in lighting control and
other load switching
systems. It is the most basic
and cost-effective way to
remotely control loads. The
PRC25 is ideal for any
building that requires a fixed
lighting control scheme with
a low installed cost.
Examples may include small
commercial buildings, tenant
spaces, and other light
commercial facilities.
Pow-R-Command 100 Universal
System Controller (PRC100 USC)
The heart of the PRC100
panelboard is the Universal
System Controller. Integral to
the panelboard, this controller
provides the PRC100
panelboard with distributed
intelligence to control
solenoid operated circuit
breakers. The controller has
the ability to communicate
with other panelboard
mounted controllers using a
shielded twisted pair network
cable. To further support
system integrations, the
PRC100 is also available in
two additional native protocol
versions that are installed in
the PRC100 panelboard. The
PRC100MOD is a native
Modbus protocol controller
that can be integrated easily
into an existing or new
Modbus system. Also
available is the PRCJCI, a
native JCI Metasys protocol
controller, which is used in
new or existing JCI system
integrations.
Pow-R-Command PRC100
Panelboard Standard Features
●
Time-of-Day scheduling—
Each breaker may be
individually time scheduled
●
Holiday scheduling
●
Astronomical scheduling
●
Memory loss protection
●
Real-time clock
●
Hardware diagnostics
●
Power failure recovery
●
Brownout recovery
●
Alarms and alarm log
●
Local programming port
●
Network communications
port
●
Breaker bypass On/Off and
restore buttons
●
Lights-off warning
●
Load priority management
●
Plug-and-play installation
●
Data logging
●
12 dry contact switch
inputs
Pow-R-Command PRC100
Panelboard Network
Should more than one
panelboard be required for a
facility, Pow-R-Command
panelboards can be
networked to form a system.
This allows each panelboard
to communicate with each
other and to a central
computer over a shielded
twisted pair network cable.
Pow-R-Command PRC100
Panelboard Optional Features:
The Pow-R-Command
PRC100 panelboard may be
ordered with an optional
factory-installed Expansion
Chassis in addition to the
factory-installed Universal
System Controller. The
optional Expansion Chassis
houses up to two PRC100
Application Specific
Controllers (ASC), which may
be field installed. The addition
of the optional Expansion
Chassis and Application
Specific Controllers to the
standard PRC100 panelboard
will extend the functionality
of the PRC100 panelboard
beyond time-of-day power
Volume 2—Commercial Distribution CA08100003E—December 2010
10.6
switching.
10
PRC100 Application
Specific Controllers
Eaton’s Pow-R-Command
Application Specific
Controllers (ASCs) are
designed to expand the
PRC100 panelboard system
beyond time-of-day power
switching requirements. The
controllers may be plugged
into the PRC100EC
panelboard and the
PRC100SCC Control Cabinet.
10
10
10
10
10
10
10
10
10
10
10
10
10
PRC100SCC Control Cabinet with
Application Specific Controllers
Switch Override Controller
(PRC100SOC)
The Switch Override
Controller provides the ability
to connect and monitor up to
48 dry contact closures from
wall switches, occupancy
sensors, photocells, building
automation system relay
contacts or any remotely
mounted device with a dry
contact relay. Input
connections to the controller
are self powered with 28 Vac
and may be individually
custom programmed to
operate differently. It is
possible to program any
connected input to control
any breaker or group of
breakers in the panelboard or
system. Inputs have
adjustable priorities and are
capable of being individually
time schedule enabled for
different days of the week.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
449
10.6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Panelboards and Lighting Control
Pow-R-Command
Telephone Override Controller
(PRC100TOC)
The Telephone Override
Controller provides a voice
prompted method for On/Off
override control of lighting.
The telephone override
controller is connected the
same as an extension
telephone. Simply plug it into
a local analog telephone
extension wall jack. The
telephone override controller
allows voice prompted
control of lighting circuits for
up to 1000 individual users. It
is possible to program any of
the 1000 users to override
any breaker, or group of
breakers in the panelboard, or
system on or off during
scheduled or non-scheduled
hours, using any touch-tone
telephone.
Remote Access Controller
(PRC100RAC)
Allows programming and
monitoring of the Pow-RCommand system from a
remote location using a
personal computer with a
modem. The RAC is ideal for
multi-location systems, such
as campus and chain stores.
Only one RAC is required per
system to accomplish this
task. The system can be
designed to allow various
levels of access. All
programming and monitoring
functions are available from
the central location.
PRC100 Network Interface Box
(PRC100NIB)
The Network Interface Box
allows the central computer
to be located more than 25
feet (7.6m) from the closest
Pow-R-Command
panelboard. The Network
Interface Box comes
complete with serial interface
cable and power cord.
PRC100 Control Cabinet
The PRC100 Control Cabinet
incorporates a power supply
and the Universal System
Controller from the PRC100
panelboard into a cabinet that
may house up to three ASCs.
The PRC100 Control Cabinet
is ideal for retrofit
applications when the
existing panelboards may be
reused or new construction
applications where two or
more panelboards requiring
switched loads are located
within the same electrical
closet. The PRC100 Control
Cabinet will control up to 48
remotely mounted circuit
breakers using preterminated pigtail cables.
PRC100 Setup Software
(PRC100LOS)
Windows®-based setup
software is required for
programming the PRC100
panelboard and Application
Specific Controllers.
PRC100 System Support
Application Engineering
support is available from the
Pow-R-Command
Applications Engineering
Group located in the Sumter,
SC, plant.
PRC100 Field Technical Support
Programming, Startup,
Training and Field Service are
available from a professional
team of factory trained
engineers. Startup services
are recommended to ensure
peak system performance.
Online Support
Available to those customers
who choose Remote Access
Controllers. Factory
technicians can help diagnose
systems, set up or change
programs and troubleshoot
online.
10
10
10
10
10
10
10
10
10
10
10
450
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Product Selection Guide
10
Pow-R-Command Selection Guide
10
10
10
10
10
Controller
PRC25
PRC50
PRC100
PRC750
PRC1000
PRC2000
PRC2000B
Mandatory Eaton startup and integration required
No
No
Yes
No
Yes
Yes
No Switch
6
8
4
8
8
8
8
Universal (switch or analog)
0
0
8
8
8
8
8
10
10
Inputs
Optional switch input expander
0
0
48
0
48
48
48
Total inputs
6
8
64
16
64
64
64
Outputs digital (maximum controllable zones)
6
0
4
16
75
75
75
Analog
0
0
4
0
4
4
4
Universal I/O module
No
No
Yes
No
Yes
Yes
Yes
Telephone override
No
No
Yes
No
Yes
Yes
Yes
10
10
10
Outputs
Data logging
No
No
Yes
No
Yes
Yes
Yes
Remote access
No
No
Yes
No
Yes
Yes
Yes
Power supply for external devices
N/A
No
Yes
Yes
Yes
Yes
Yes
Maximum number of loads (breaker/relay)
42
42
42
168
168
168
168
Number of expansion panels
0
0
0
7
7
7
7
Manual override
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10
10
10
10
10
10
Notes
Startup and Integration by Eaton is not mandatory when utilizing the PRC2000B with BACnet protocol.
Each rail drives 21 breakers. Rails can be distributed individually over a total of eight panels (max. SLAN wire-length of 150 ft).
10
10
10
10
10
10
10
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
451
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Pow-R-Command Selection Guide, continued
PRC25
PRC50
PRC100
PRC750
PRC1000
PRC2000
PRC2000B
Dimming
No
No
Yes
No
Yes
Yes
Yes
Maximum number of dimming ballasts
0
0
160
0
160
160
160
Daylight harvesting (using dimming ballasts)
No
No
Yes
No
Yes
Yes
Yes
Daylight switching (on/off circuit switching)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10
Time clock
No
No
Yes
Yes
Yes
Yes
Yes
Time schedules
No
No
Yes
Yes
Yes
Yes
Yes
10
Scheduling zones
N/A
N/A
75
75
75/250 75/250 75/250 10
10
10
Controller
Outputs (continued)
On/off periods per schedule
N/A
N/A
50
50
50
50
50
Holidays
N/A
N/A
30
30
30/16 30/16 30/16 Blink notice
No
No
Yes
Yes
Yes
Yes
Yes
Maximum override time (hrs)
N/A
N/A
24
24
24
24
24
RS-232 port
No
No
No
No
No
No
No
RS-485 port
No
No
Yes
No
Yes
Yes
Yes
10
Ethernet port
No
No
No
No
No
Yes
Yes
Ethernet via external gateway
No
No
Yes
No
Yes
Yes
Yes
10
Input/output matrix across controllers
No
No
Yes
No
Yes
Yes
Yes
Input/output matrix within controller
No
Yes
Yes
Yes
Yes
Yes
Yes
10
Local LCD/LED display
No
No
No
Yes
Option
Option
Option
Local LED status indicators
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Non-volatile program memory
No
Yes
Yes
Yes
Yes
Yes
Yes
Battery backup for program memory
N/A
10 yrs
10 yrs
10 yrs
10 yrs
10 yrs
10 yrs
Clock memory backup
N/A
10 yrs
10 yrs
10 yrs
10 yrs
10 yrs
10 yrs
10
Flash firmware memory
N/A
No
No
Yes
Yes
Yes
Yes
10
Modbus® ASCII/RTU
N/A
N/A
Yes
No
No
No
N/A
Modbus TCP
N/A
N/A
No
No
No
No
N/A
10
Johnson Controls® N2
N/A
N/A
Yes
No
No
No
N/A
BACnet
N/A
N/A
Yes
No
Yes
Yes
Yes
10
10
10
10
10
10
10
Protocols
LonWorks®
N/A
N/A
No
No
No
No
N/A
SOAP/XML
N/A
N/A
Yes
No
Yes
Yes
N/A
OPC
N/A
N/A
Yes
No
Yes
Yes
Yes
N/A
No
Yes
No
Yes
Yes
Yes
10
Browser Access
10
Built-in Web Server
TCP/IP
N/A
No
No
N/A
N/A
Yes
Yes
10
BACnet IP server
N/A
No
No
N/A
N/A
N/A
Yes
TCP/IP external device
Standards
10
UL 916 energy management equipment
Yes
Yes
Yes
Yes
Yes
Yes
Yes
California Title 24
N/A
N/A
Yes
Yes
Yes
Yes
Yes
NEC 110-10
—
Yes
Yes
Yes
Yes
Yes
Yes
10
UL 67 panelboards
Yes
Yes
Yes
Yes
Yes
Yes
Yes
CSA C22.2 #29 panelboards
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10
Baud rate
N/A
9.6k
9.6k
9.6k
9.6k
9.6k
9.6k
Maximum controllers/network
N/A
1
120
1
1800
1800
1800
10
Password protected
No
No
Yes
Yes
Yes
Yes
Yes
Three-pole breaker housing
No
No
No
No
No
No
No
External bracket mount available
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10
Mounting
10
10
10
Notes
250 additional schedules with optional Network Interface Box NIB.
16 additional holidays with optional Network Interface Box NIB.
452
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Contents
Pow-R-Command 4000 Wireless Controller
Description
Page
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000)
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
447
451
454
457
460
463
467
470
473
An Eaton
Green Solution
10
10
10
10
10
10
10
10
10
10
10
Pow-R-Command 4000 (PRC4000)
10
Product Description
The PRC4000 wireless
controller is designed to act
as the coordinator of the
wireless lighting network; All
configuration and control can
be done through a standard
Web browser instead of
learning a new software
platform. In addition, the
PRC4000 is networkable with
existing Pow-R-Command
lighting control products over
the RS-485 network to
expand system capabilities.
The PRC4000 also comes
equipped with analog and
digital inputs/outputs to
accommodate an extended
array of input devices,
switching and dimming
needs. The PRC4000
wirelessly communicates to
the PRCWIOM and the PRC
Wireless Switch using the
IEEE®802.15.4 standard.
Components
●
Embedded Web server
●
Integrated I/O
●
PRC Wireless I/O Module
●
PRC Wireless Switch
PRC Wireless I/O Module
The PRC4000 wireless
controller offers industryleading wireless technology.
Not only does it have a builtin radio to communicate
wirelessly directly with each
I/O module and wireless
switch, but it also offers
many advanced features to
help coordinate your lighting
network. The PRC4000 has a
built-in battery-backed time
clock. In addition to its
advanced time-scheduling
feature set, the PRC4000
also offers astronomical time
scheduling that dynamically
adjusts to your geographic
location and time of year.
With any automated system,
data logging and alarm
notifications are essential. To
meet this need, the PRC4000
offers an integrated internal
data and alarm notification
system. This gives you
access to valuable
information that you would
need to quickly see the status
of your lighting system.
PRC Wireless Devices
PRC Wireless I/O Module
(PRCWIOM)
The PRCWIOM is used to
segment the system and
connect external inputs and
loads to the system remotely.
It allows local connectivity of
low voltage switches, photo
sensors, occupancy sensors,
0–10 Vdc dimming ballasts,
and other auxiliary devices.
The I/O module also adds
discrete on/off load control
through an onboard relay for
loads up to 120/277V, 20A.
Running control wires from
each device in the facility
back to the electrical room is
no longer required. The
configuration and
programming is stored in the
internal memory of the PRC
Wireless I/O module and the
PRC Wireless Switch. This
allows for distributed
intelligence that adds
reliability to an already robust
lighting control network.
PRC Wireless Switch Interface
Pow-R-Command line of
lighting controllers through a
Pow-R-Command Wireless
Switch Interface (PRCWSI)
unit. Each PRCWS switch is
completely customizable and
can be programmed to meet
the needs of the customer’s
lighting control strategy. The
PRCWS configuration is
stored directly in the
integrated memory of the
switch, which adds to the
reliability of the device. In
addition to the wireless
network communication
capabilities, the PRCWS has
built-in input and output that
are capable of connecting a
photo sensor, occupancy
sensor, and dimmable
ballasts to achieve a fully
integrated zone lighting
control from one device. The
wireless switch network can
have up to 99 switches per
controller.
PRC Wireless Switch
(PRCWS)
PRC Wireless Switch
Interface (PRCWSI)
The PRC Wireless Switch
is a state-of-the-art,
microprocessor-based,
low voltage wireless
communication device
that is based on the 802.15.4
wireless standard. The switch
is used for local control
and has the ability to
communicate directly to the
PRC4000 and to the standard
The PRCWSI is a wireless
gateway device that passes
the wireless data of the PRC
Wireless Switch to the PRC
Digital Switch network of the
PRC1000 or PRC2000
Controller. This two-way
communication transfers
commands from the switch
as well as feedback from the
controller.
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
10
10
10
10
10
10
10
10
10
10
10
10
10
453
10
10
10
10
10
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Contents
Pow-R-Command 2000 Panelboard
Description
10
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
10
10
10
10
10
10
447
451
453
455
456
478
457
460
463
467
470
473
An Eaton
Green Solution
10
10
10
10
10
10
10
10
Pow-R-Command 2000 Panelboard
Product Description
Features
Eaton’s Pow-R-Command
2000 is a microprocessor-based
programmable lighting control
system with an embedded
Web server for robust control.
The PRC2000 can be used as a
standalone panelboard or
networked as a system. An
upgrade can be purchased to
integrate the unit within
BACnet native control
networks.
●
10
●
●
●
●
●
●
●
●
●
10
●
10
●
10
LCD display and keypad
Memory loss protection
Power failure/brownout
recovery
Astronomical real-time
clock
Control software
Time scheduling
Holiday scheduling
Input to output switch
matrix
Messages/alarms
Daylight optimization
Switch Override Controller
(SOC)
Telephone Override
Controller (TOC)
Components
Embedded Web server
●
Intelligent power switching
equipment
●
LCD programming display
and keypad
●
Application Specific
Controllers (ASCs)
●
Software and support
●
Integration components
10
●
10
10
10
10
Intelligent Power
Switching Equipment
PRC2000 Panelboards
10
10
208Y/120V and 480Y/277V,
single-phase and threephase. The panelboard
utilizes both branch mounted
standard breakers through
100A, and controllable
thermal-magnetic breakers
that are controlled by the
PRC2000 System Controller.
The PRC2000 controllers
provide the ability to directly
operate up to eight breaker
control buses that are installed
in the PRC2000 panelboard
and the various PRCEP
panelboards with one or two
breaker control bus installed in
each. Such a capability allows a
single controller to directly
operate up to 168 GHQRSP
and BABRSP controllable
circuit breakers, with individual
control and status feedback of
each controllable breaker.
The System Controller also
includes load override,
holiday scheduling, one-shot
or event schedules, off warning
to tenants by blinking lights,
memory loss protection,
power failure/brownout
protection, hardware
diagnostics, a real-time
clock and 16 dry contact
switch inputs.
Equipment within the
PRC2000 system may be
networked. Up to 120
panelboards may be
networked over a shielded
twisted pair network cable
without the need for a
personal computer in the
system. To better support
retrofit applications, the
PRC2000 is offered in an
external cabinet and the
Breaker Control Bus is offered
in retrofit kits.
BACnet Protocol
The PRC2000 unit can also be
used for integration within
BACnet native control
networks. BACnet is a
communications protocol
widely used in building
automation and controls and
adds even more flexibility to
the control system.
Standards and Certifications
The Pow-R-Command 2000
Panelboard is listed UL 67 for
panelboards and UL 916 for
energy management
equipment.
PRC2000 panelboards are
offered from 100–225A
in main lug and main
configurations. Available
voltages are 120/240V,
10
10
454
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Technical Data and Specifications
System Configurations
PRC2000 Network
Architecture
10
Breaker Control Buses
(BCB)
Containing an embedded
webserver, each PRC2000
system is programmed with a
unique IP address for
communication via any
standard Internet browser.
Web access is standard with
the PRC2000. Eight 21-circuit
control buses configured as
needed throughout PRL1A
and PRL2A panels. The
PRC2000B directly interfaces
to a BACnet Client
Workstation.
10
Every Pow-R-Command
Expansion Panelboard can be
configured with the left and/
or right breaker control buses
installed. When using PRC EP
Panel with one BCB, the
remote-controlled breakers
are placed on the side with
the control bus. Standard and
controlled breakers can be
distributed anywhere in the
panel as needed.
10
10
10
10
10
10
10
PRC2000 Breaker Control Busses
10
10
PRC
EP
2
BCBs
PRC
EP
1
BCB
10
10
5th Floor
Sub LAN 4 Conductor Cable
10
PRC
EP
2
BCBs
PRC
EP
1
BCB
10
4th Floor
10
Sub LAN 4 Conductor Cable
10
PRC
EP
2
BCBs
PRC
EP
2
BCBs
10
3rd Floor
10
Sub LAN 4 Conductor Cable
PRC
2000
2
BCBs
PRC
EP
2
BCBs
10
10
2nd Floor
Sub LAN 4 Conductor Cable
PRC
2000
2
BCBs
Customer Ethernet LAN
10
PC with
Internet
Browser
10
10
Ground
Each Pow-R-Command 2000 Typical for
8 Breaker Control Busses Each with 21 Breakers
10
Remote
Access
Thru
VPN
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
455
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Panel Layout
PRC2000 Layout
10
Controller
10
ckt
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
10
10
10
10
10
10
10
10
10
10
14 in.–18 Ckt. Chassis Includes PRC2000
Controller
ckt
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
20 in.–30 Ckt. Chassis Includes PRC2000
Controller
26 in.–42 Ckt. Chassis Includes PRC2000
Controller
Main Lug Section
2 in.—100 Amp MLO
4 in.—225 Amp MLO
6 in.— 400 Amp MLO
Vertically Mounted
8 in.—100 Ampere Frame EHD, EDB, EDS, ED,
EDH, FD, HFD
10
PRC2000 Panel Layout
Instructions
1. Select PRC2000
Panelboard Chassis from
layout on left.
Layout Example
1. Panel Description:
a. PRC2000, threephase four-wire,
208Y/120 Vac,
interrupting rating
of 10 kAIC
symmetrical:
225A main lugs only
at bottom, surface
mounted and the
following branch
breakers
b. 36–20A, single-pole
BABRSP
c. 6–20A, single-pole
BABRSP spaces
2. Layout information from
layout on left.
a. Determine required
mains (lugs or
breaker)
b. Select appropriate
main lug
c. Select appropriate
main device
d. Select appropriate
branch breakers
2. Layout panel as shown
on left. Total “in.”
determine box height
shown in on left. (When
total “in.” units exceeds
the number shown, use
next size box size.
a. PRC2000 with 42circuit Interior
26 inches
b. 225A main lugs
Section 4 inches
c. Total panelboard
height 30 inches
3. From table below:
9 in. — 225 Ampere Frame EDB, EDS, ED, EDH,
FD, HFD, FDC
10
●
22 in.—400 Ampere Frame DK, KD, HKD, KDC
●
10
●
10
●
10
10
Approximate Dimensions in Inches (mm)
10
Box Selection
10
Maximum
Panel Height
Box Height,
Catalog Number
YS Box LT Trim
Panel height: 30 inches
20 inches wide x 5.75
inches deep
Box height: 48 inches
Box catalog number:
YS2048 or EZB2048R
Trim catalog number:
LT2048S or EZT2048S
EZ Box
EZ Trim
20-Inch Wide x 5.75-Inch Deep Boxes
10
0–22.00
36.00 (914.4)
YS2036
LT2036S or F
EZB2036R
EZT2036S or F
10
23.00–28.00
42.00 (1066.8)
YS2042
LT2042S or F
EZB2042R
EZT2042S or F
29.00–34.00
48.00 (1219.2)
YS2048
LT2048S or F
EZB2048R
EZT2048S or F
10
35.00–46.00
60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
47.00–58.00
72.00 (1828.8)
YS2072
LT2072S or F
EZB2072R
EZT2072S or F
10
10
Cabinets
Trims are code gauge steel,
ANSI 61 light gray painted
finish. Boxes are code gauge
galvanized steel without
knockout. Standard size
is 20.00 inches (508.0 mm)
wide x 5.75 inches
(146.1 mm) deep.
10
Note: Width of enclosure will be
28.00 inches (711.2 mm) minimum.
10
10
10
456
Volume 2—Commercial Distribution CA08100003E—December 2010
Top and Bottom Gutters
6.38 inches (162.1 mm).
Minimum Side Gutters
4.00-inch (101.6 mm)
minimum on 20.00-inch
(508.0 mm) wide box size.
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Contents
Pow-R-Command 1000 Panelboard
Description
Page
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
447
451
453
454
458
459
478
460
463
467
470
473
10
10
10
10
10
10
10
10
10
An Eaton
Green Solution
10
10
Pow-R-Command 1000 Panelboard
Product Description
Features
Eaton’s Pow-R-Command
1000 is a microprocessor-based
programmable lighting control
system. The PRC1000 can be
used as a standalone
panelboard or networked as a
system.
●
●
●
●
●
●
●
●
●
●
●
●
LCD display and keypad
Memory loss protection
Power failure/brownout
recovery
Astronomical real-time
clock
Control software
Time scheduling
Holiday scheduling
Input to output switch
matrix
Messages/alarms
Daylight optimization
Switch Override Controller
(SOC)
Telephone Override
Controller (TOC)
Components
●
Intelligent power switching
equipment
●
LCD programming display
and keypad
●
Application Specific
Controllers (ASCs)
●
Software and support
●
Integration components
10
Intelligent Power
Switching Equipment
PRC1000 Panelboards
PRC1000 panelboards are
offered from 100–225A in
main lug and main breaker
configurations. Available
voltages are 120/240V, 208Y/
120V and 480Y/277V, singlephase and three-phase. The
panelboard utilizes both
branch mounted standard
breakers through 100A, and
controllable thermal-magnetic
breakers that are controlled by
the PRC1000 System
Controller. The PRC1000
controllers provide the ability to
directly operate up to eight
breaker control buses. To
better support retrofit
applications, the PRC1000 is
offered in an external cabinet
and the Breaker Control Bus is
offered in retrofit kits. Such a
capability allows a single
controller to directly operate up
to 168 GHQRSP and BABRSP
controllable circuit breakers,
with individual control and
status feedback of each
controllable breaker.
The System Controller also
includes load override,
holiday scheduling, one-shot
or event schedules, off warning
to tenants by blinking lights,
memory loss protection,
power failure/brownout
protection, hardware
diagnostics, a real-time
clock and 16 dry contact
switch inputs.
Equipment within the
PRC1000 system may be
networked. Up to 120
panelboards may be
networked over a shielded
twisted pair network cable
without the need for a
personal computer in the
system that are installed in
the PRC1000 panelboard and
the various PRCEP
panelboards with one or two
breaker control bus installed
in each.
Standards and Certifications
The PRC1000 panelboard is
listed UL 67 for panelboards
and UL 916 for energy
management equipment.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
457
10.6
10
10
Panelboards and Lighting Control
Pow-R-Command
Technical Data and Specifications
System Configurations
PRC1000 Application
10
Customizable extension
panels allow for combinations
of both regular and remote
controllable breakers for
individualized solutions as
shown in this riser diagram.
Eaton’s PRC1000 Controller
can support up to eight
10
PRC1000 Breaker Control Buses
10
10
10
Breaker Control Buses
contained within four standard
panelboards or split between
a maximum of eight. When
connected to the building’s
Internet, all master and
expansion panels can be
controlled.
10
10
PRC
EP
2
BCBs
PRC
EP
1
BCB
10
5th Floor
10
Sub LAN 4 Conductor Cable
10
10
4th Floor
Sub LAN 4 Conductor Cable
10
PRC
EP
2
BCBs
PRC
EP
2
BCBs
10
10
PRC
EP
2
BCBs
PRC
EP
1
BCB
3rd Floor
Sub LAN 4 Conductor Cable
10
PRC
1000
2
BCBs
PRC
EP
2
BCBs
10
2nd Floor
10
Sub LAN 4 Conductor Cable
PRC
1000
2
BCBs
10
10
RS-485
Network
Interface
PC
with
Software
Ground
10
Remote
Access
Thru
Modem
10
10
10
10
10
10
10
10
458
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
10.6
Panelboards and Lighting Control
Pow-R-Command
Panel Layout
PRC1000 Layout
14 in. - 18 Ckt. Chassis Includes PRC1000
Controller
Controller
ckt
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
ckt
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
20 in. - 30 Ckt. Chassis Includes PRC1000
Controller
26 in. - 42 Ckt. Chassis Includes PRC1000
Controller
Main Lug Section
2 in.—100 Amp MLO
4 in.—225 Amp MLO
6 in.— 400 Amp MLO
Vertically Mounted
8 in.—100 Ampere Frame EHD, EDB, EDS, ED,
EDH, FD, HFD
PRC1000 Panel Layout
Instructions
1. Select PRC1000
Panelboard Chassis from
layout on left.
a. Determine required
mains (lugs or
breaker)
b. Select appropriate
main lug
c. Select appropriate
main device
d. Select appropriate
branch breakers
2. Layout panel as shown
on left. Total “in.”
determine box height
shown on left. (When
total “in.” units exceeds
the number shown, use
next size box size.
Layout Example
1. Panel Description:
10
a. PRC1000, threephase four-wire,
208Y/120 Vac,
interrupting rating
of 10 kAIC
symmetrical:
225A main lugs only
at bottom, surface
mounted and the
following branch
breakers
b. 36–20A, single-pole
BABRSP
c. 6–20A, single-pole
BABRSP spaces
2. Layout information from
layout on left.
10
●
22 in.—400 Ampere Frame DK, KD, HKD, KDC
●
●
●
10
10
10
10
10
10
10
a. PRC1000 with
42-circuit Interior
26 inches
b. 225A main lugs
section 4 inches
c. Total panelboard
height 30 inches
3. From table below:
9 in. — 225 Ampere Frame EDB, EDS, ED, EDH,
FD, HFD, FDC
10
10
10
10
Panel height: 30 inches
20 inches wide x 5.75
inches deep
Box height: 48 inches
Box catalog number:
YS2048 or EZB2048R
Trim catalog number:
LT2048S or EZT2048S
10
10
10
10
10
Approximate Dimensions in Inches (mm)
10
Box Selection
10
Maximum
Panel Height
Box Height,
Catalog Number
YS Box LT Trim
EZ Box
EZ Trim
10
10
20-Inch Wide x 5.75-Inch Deep Boxes
0–22.00
36.00 (914.4)
YS2036
LT2036S or F
EZB2036R
EZT2036S or F
23.00–28.00
42.00 (1066.8) YS2042
LT2042S or F
EZB2042R
EZT2042S or F
29.00–34.00
48.00 (1219.2) YS2048
LT2048S or F
EZB2048R
EZT2048S or F
35.00–46.00
60.00 (1524.0) YS2060
LT2060S or F
EZB2060R
EZT2060S or F
47.00–58.00
72.00 (1828.8) YS2072
LT2072S or F
EZB2072R
EZT2072S or F
Cabinets
Trims are code gauge steel,
ANSI 61 light gray painted
finish. Boxes are code gauge
galvanized steel without
knockout. Standard size is
20.00 inches (508.0 mm)
wide x 5.75 inches
(146.1 mm) deep.
Top and Bottom Gutters
6.38 inches (162.1 mm).
10
10
10
Minimum Side Gutters
10
4.00-inch (101.6 mm)
minimum on 20.00-inch
(508.0 mm) wide box size.
10
10
Note: Width of enclosure will be
28.00 inches (711.2 mm) minimum.
Volume 2—Commercial Distribution CA08100003E—December 2010
10
10
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
459
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Contents
Pow-R-Command 750 Panelboard
Description
10
Page
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard
Technical Data and Specifications . . . . . . . . . . . . . . . . . .
Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
10
10
10
10
10
10
447
451
453
454
457
461
462
478
463
467
470
473
An Eaton
Green Solution
10
10
10
10
10
10
10
Pow-R-Command 750 Panelboard
Product Description
Features
Eaton’s Pow-R-Command
750 is a microprocessorbased programmable lighting
control system. The PRC750
can be used as a standalone
panel, or the user has the
option to connect up to three
expansion panels, creating its
own standalone subnetwork.
●
●
●
●
●
●
●
10
●
10
●
●
10
●
10
●
10
LCD display and keypad
Memory loss protection
Power failure/brownout
recovery
Astronomical real-time
clock
Control software
Time scheduling
Holiday scheduling
Input to output switch
matrix
Messages/alarms
Daylight optimization
Switch Override Controller
(SOC)
Telephone Override
Controller (TOC)
Components
Intelligent power switching
equipment
●
LCD programming display
and keypad
●
Integration components
10
●
10
10
10
10
Intelligent Power
Switching Equipment
PRC750 Panelboards
PRC750 panelboards are
offered from 100–225A in
main lug and main breaker
configurations. Available
voltages are 120/240V, 208Y/
120V and 480Y/277V, singlephase and three-phase. The
panelboard utilizes both
branch mounted standard
breakers through 100A, and
controllable thermal-magnetic
breakers that are controlled
by the PRC750 system
controller. The PRC750
controllers provide the ability
to directly operate up to eight
breaker control buses. To
better support retrofit
applications, the PRC750 is
offered in an external cabinet
and the Breaker Control Bus is
offered in retrofit kits. Such a
capability allows a single
controller to directly operate
up to 168 GHQRSP and
BABRSP controllable circuit
breakers, with individual
control and status feedback
of each controllable breaker.
The System Controller also
includes load override,
holiday scheduling, one-shot
or event schedules, off warning
to tenants by blinking lights,
memory loss protection,
power failure/brownout
protection, hardware
diagnostics, a real-time clock
and 16 dry contact switch
inputs that are installed in the
PRC750 panelboard and the
various PRCEP panelboards
with one or two breaker
control bus installed in each.
Standards and Certifications
The PRC750 panelboard is
listed UL 67 for panelboards
and UL 916 for energy
management equipment.
10
10
10
10
460
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Technical Data and Specifications
Designed for standalone
applications, Eaton’s PRC750
is a premier microprocessorbased lighting control system
that can be used to control all
of the lighting in your
industrial facilities, high-rise
office buildings and airports.
A single PRC750 panel can be
connected to a maximum of
eight Breaker Control Buses
10
(BCB) in any combination
within panelboards for the
ability to control up to a total
of 168 Smart Breakers. The
PRC750 also boasts load
override, holiday scheduling,
memory loss protection,
astronomical time clocks and
scheduling, 16 switch inputs,
and alarm and message log
features.
10
10
10
10
10
10
PRC750 Standalone System Architecture
10
PRC
EP
1
BCB
10
10
5th Floor
Sub LAN 4 Conductor Cable
10
PRC
EP
1
BCB
10
4th Floor
10
Sub LAN 4 Conductor Cable
10
PRC
EP
2
BCBs
10
3rd Floor
10
Sub LAN 4 Conductor Cable
PRC
EP
2
BCBs
10
10
2nd Floor
Sub LAN 4 Conductor Cable
PRC
750
2
BCBs
10
Programming via Local LCD Display
10
No Start-Up Required by Factory
10
Ground
10
10
10
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
461
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Panel Layout
PRC750 Layout
10
Controller
10
ckt
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
10
10
10
10
10
10
10
10
10
10
14 in. - 18 Ckt. Chassis Includes PRC750
Controller
ckt
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
20 in. - 30 Ckt. Chassis Includes PRC750
Controller
26 in. - 42 Ckt. Chassis Includes PRC750
Controller
Main Lug Section
2 in.—100 Amp MLO
4 in.—225 Amp MLO
6 in.—400 Amp MLO
Vertically Mounted
8 in.—100 Ampere Frame EHD, EDB, EDS, ED,
EDH, FD, HFD
10
PRC750 Panel Layout
Instructions
1. Select PRC750
Panelboard Chassis from
layout on left.
Layout Example
1. Panel description:
a. PRC750, three-phase
four-wire, 208Y/120
Vac, interrupting
rating of 10 kAIC
symmetrical:
225A main lugs only
at bottom, surface
mounted and the
following branch
breakers
b. 36–20A, single-pole
BABRSP
c. 6–20A, single-pole
BABRSP spaces
2. Layout information from
layout on left.
a. Determine required
mains (lugs or
breaker)
b. Select appropriate
main lug
c. Select appropriate
main device
d. Select appropriate
branch breakers
2. Layout panel as shown
on left. Total “in.”
determine box height
shown on left. (When
total “in.” units exceeds
the number shown, use
next size box size.
a. PRC750 with
42-circuit Interior
26 inches
b. 225A main lugs
section 4 inches
c. Total panelboard
height 30 inches
3. From table below:
●
9 in.—225 Ampere Frame EDB, EDS, ED, EDH,
FD, HFD, FDC
10
22 in.—400 Ampere Frame DK, KD, HKD, KDC
●
10
●
10
●
Panel height: 30 inches
20 inches wide x 5.75
inches deep
Box height: 48 inches
Box catalog number:
YS2048 or EZB2048R
Trim catalog number:
LT2048S or EZT2048S
10
Approximate Dimensions in Inches (mm)
10
Box Selection
10
Maximum
Panel Height
10
Box Height,
Catalog Number
YS Box LT Trim
EZ Box
EZ Trim
20-Inch Wide x 5.75-Inch Deep Boxes
10
0–22.00
36.00 (914.4)
YS2036
LT2036S or F
EZB2036R
EZT2036S or F
23.00–28.00
42.00 (1066.8) YS2042
LT2042S or F
EZB2042R
EZT2042S or F
10
29.00–34.00
48.00 (1219.2) YS2048
LT2048S or F
EZB2048R
EZT2048S or F
35.00–46.00
60.00 (1524.0) YS2060
LT2060S or F
EZB2060R
EZT2060S or F
47.00–58.00
72.00 (1828.8) YS2072
LT2072S or F
EZB2072R
EZT2072S or F
10
10
Cabinets
Trims are code gauge steel,
ANSI 61 light gray painted
finish. Boxes are code gauge
galvanized steel without
knockout. Standard size is
20.00 inches (508.0 mm)
wide x 5.75 inches
(146.1 mm) deep.
10
10
10
10
Top and Bottom Gutters
6.38 inches (162.1 mm).
Minimum Side Gutters
4.00-inch (101.6 mm)
minimum on 20.00-inch
(508.0 mm) wide box size.
Note: Width of enclosure will be
28.00 inches (711.2 mm) minimum.
10
462
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Contents
PRC100 Panelboard
Description
Page
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
447
451
453
454
457
460
10
464
466
478
467
470
473
10
10
10
10
10
10
10
An Eaton
Green Solution
10
10
PRC100 Panelboard
Product Description
Standards and Certifications
Eaton’s Pow-R-Command is
designed to meet the needs
for microprocessor-based
programmable lighting control.
Used as a standalone
panelboard or networked as a
system, the Pow-R-Command
PRC100 offers the broadest
range of energy control in the
industry. The PRC100
panelboard system is ideal for
large, medium and small
building applications. The
Pow-R-Command panelboard
mounts the same as
traditional panelboards. Power
and branch wiring is also the
same. It can be applied to
distribution systems rated
single-phase three-wire and
three-phase four-wire 120V,
120/240V, 208Y/120V and
480Y/277 Vac.
●
●
●
●
●
●
●
10
UL 67 Panelboards
UL 50 Enclosures
UL 916 Energy
Management Equipment
National Electrical Code
Federal Specification
W-P-115C
FCC Emissions Standards:
Part 15, Subject J for Class
A Application
IBC and UBC Seismic
Qualified Equipment is
available
10
10
10
10
10
10
10
10
10
10
10
See Page 447 for additional
information.
10
Branch Breakers
●
Refer to Page 465.
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
463
10.6
10
10
Panelboards and Lighting Control
Pow-R-Command
Product Selection
Type PRC100
10
PRC100 Panelboard
Ampere
Rating
10
Main Integral Fuse Disconnect—Series Rated Combinations
Interrupting Rating (kA Symmetrical)
Device
240V
480Y/277V
Type
Main Lug Only 10
100
—
—
MLO
250
—
—
MLO
10
400
—
—
MLO
Main Breaker 10
100
18
14
EHD
10
100
18
14
FDB
100
65
35
FD
10
100
100
65
HFD
100
200
100
FDC
100
200
150
FCL
100
200
200
FB-P 225
22
—
EDB
10
225
42
—
EDS
225
65
—
ED
10
225
100
—
EDH
225
200
—
EDC
225
65
35
FD
10
225
100
65
HFD
225
200
100
FDC
10
250
65
35
JD
250
100
65
HJD
10
250
200
100
JDC
400
65
—
DK
400
65
35
KD
10
400
100
65
HKD
400
200
100
KDC
10
400
200
100
LCL 10
10
10
10
Ampere
Rating
Interrupting Rating
(kA Symmetrical)
240V
480Y/277V
100
100
200
65
Device
Type
Approved Branch
Devices
100
T Fuse
Disconnect GHB, GHBS,
EHD, FDB, FD
65
T Fuse
Disconnect GHB, GHBS,
EHD, FDB, FD
Notes
The short-circuit rating of the MLO assembled panelboard may be fully rated based upon
the lowest rated branch breaker or series rated with an approved upstream device.
The short-circuit rating shown is that of the main breaker only. The rating of the assembled
panelboard is the same as the short-circuit rating of the lowest rated main or branch device.
Top feed only.
Requires 6.50-inch (165.1 mm) deep box.
The short-circuit rating shown is the rating of the panelboard assembly with the main and
approved branch devices as listed.
Fuses not included.
Includes Smart Chassis (system controller integral to the panelboard chassis).
Lighting optimization software and startup support must be included with each
system—see Page 475.
10
10
10
10
10
10
10
10
10
10
464
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
10
BABRP Remote Control
Circuit Breaker
10
Branch Circuit Breakers—480Y/277V Maximum
Ampere Rating
Interrupting Rating (kA Symmetrical)
240V
480V
10
Breaker Type
10
Remote Controllable Branch Circuit Breakers
15–30
10
—
BABRP 15–30
10
—
BABRSP 15–20
65
14
GHQRSP 15–30
65
14
GHBS 10
10
Conventional Branch Circuit Breakers—Not Controllable
GHBS Remote Control
Circuit Breaker
15–60
10
—
10
BAB 15–60
10
—
BAB-H
70
10
—
BAB 70
10
—
BAB-H
80–100
10
—
BAB 10
10
10
80–100
10
—
BAB-H
15–50 10
—
QBGF 15–50 10
—
QBGFEP 15–20
10
—
QBCAF
15–20
65
14
GHQ 15–20
65
14
GHB 25–60
65
14
GHB 70–100
65
14
GHB 15–60
18
14
EHD
70–100
18
14
EHD
15–60
18
14
FDB
70–100
18
14
FDB
110–150
18
14
FDB
15–60
65
35
FD 70–100
65
35
FD 110–225
65
35
FD
15–60
100
65
HFD 70–100
100
65
HFD 110–225
100
65
HFD
15–60
200
100
FDC
70–100
200
100
FDC
110–225
200
100
FDC
100–225
22
—
EDB
100–225
42
—
EDS
100–225
65
—
ED 100–225
100
—
EDH 100–225
200
—
EDC 10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Notes
Single-pole breaker rated 120 Vac. two-pole breaker rated 120/240 Vac.
Single-pole breakers are rated 277 Vac maximum. Two- and three-pole breakers are rated 480Y/277 Vac maximum.
For use on 480Y/277 Vac maximum.50A devices are available as two-pole only.
GFCI for 5 mA personnel protection.
GFP for 30 mA equipment protection.
Arc fault circuit breaker.
Maximum lug size, 4/0 AWG Al/Cu in 20-inch (508.0 mm) wide box. 300 kcmil lug available in 28-inch (711.2 mm) wide box.
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
465
10.6
10
Panel Layout
10
PRC100 Layout
Panelboards and Lighting Control
Pow-R-Command
1-Pole 1-Pole 1X
EHD
10
2-Pole
2-Pole 2X
FDB
FD
10
1-Pole 3-Pole 3X
HFD
FDC
2-Pole 10
10
2-Pole 3-Pole 2X
EDB, EDS, ED, EDH
EDC
3X
EDB, EDS, ED, EDH
EDC
10
10
5X
12 Poles
10X
24 Poles
10
10
10
ckt
2
4
6
8
10
12
14
16
18
ckt
1
3
5
7
9
11
13
15
17
10
10
10
10
BABRP
BABRSP
BAB
GHBS
GHQRSP
GHB
13X
Smart Chassis
includes spaces
for 18 Poles
GHBS, GHQRSP, GHB, BABRP, BABRSP, BAB
Layout Instructions
1. Select:
a. Smart Chassis from
layout on left.
Note: Smart chassis is always
located at the bottom of the
panelboard chassis immediately
below the bottom breaker.
b. Required mains
(lugs, breaker or
fuse pullout).
c. Appropriate neutral.
d. Branch breakers and
additional chassis
space, as needed.
2. Layout panel as shown
on left, using appropriate
“X” units. Total “X” units
determine box height
shown in table below.
(When total “X” units
exceeds the number
shown, use next size
box size.
Smart Chassis is always located at the
bottom of the panelboard chassis
immediately below all GHBS/GHB or BABR/
BABRS/BAB breakers.
10
10
10
10
10
10
Neutral Section
5X
8X
100–250 A
400 A
Main Lug Section
2X
5X
8X
100 A
250 A
400 A
Main Device
Horizontally Mounted
Main Device
Vertically Mounted
10
10
10
10
10
10
7X—EHD, FDB, FD,
HFD, FDC, EDB, EDS,
ED, EDH, EDC
Box Tabulation
“X”
Units
Box
Height
YS Box
Catalog
Number
LT Trim
Catalog
Number
EZ Box
Catalog
Number
EZ Trim
Catalog
Number
100–400A
23X
48.00 (1219.2)
YS2048
LT2048S or F
EZB2048R
EZT2048S or F
31X
60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
9X—200 A
Class T fusible pullout
40X
72.00 (1828.8)
YS2072
LT2072S or F
EZB2072R
EZT2072S or F
9X—FB-P 53X
90.00 (2286.0)
YS2090
LT2090S or F
EZB2090R
EZT2090S or F
15X—DK, KD, HKD,
KDC
Notes
All F-Frame branch breakers must be mounted above (top) of all controllable breakers on the
chassis.
EDB, EDS, ED, EDH and EDC branch mounted breakers may be mounted with load lugs on either
left or right. Specify on order.
All add-on branch spaces must be adjacent to smart chassis poles.
GHBS, GHQRSP and GHB breakers cannot be mixed on same chassis with BABRP, BABRSP and
BAB breakers.
Top-mounted main—only.
466
Approximate Dimensions in Inches (mm)
7X—100 A
Class T fusible pullout
14X—JD, HJD, JDC
10
10
See branch mounted —
EHD, FD, FDB,
HFD, FDC, EDB, EDS, ED, EDH, EDC above
2. Layout information from
layout on left:
a. Smart Chassis . = 13X
b. 24-circuit add-on
chassis . . . . . . = 10X
c. 250A neutral . . = 5X
d. 250A main
lugs only . . . . . = 5X
e. Total panelboard
height . . . . . . . = 33X
3. From table below: 33X
height (use 40X box).
Box catalog
number. . . . . . . YS2072
Trim catalog
number. . . . . . LT2072S
OR
Box catalog
number. . . . . EZB2072R
Trim catalog
number. . . . . EZT2072S
Pow-R-Command
Smart Chassis and
18 Pole Spaces
10
Layout Example
1. Panel description:
a. Pow-R-Command,
three-phase, four-wire
480Y/277 Vac,
interrupting rating of
14 kAIC symmetrical,
250A main lugs only
at bottom, surface
mounted and the
following branch
breakers:
b. 36–20A, single-pole
GHBS.
c. 6–20A, single-pole
GHBS spaces.
Cabinets
Fronts are code-gauge steel,
ANSI-61 light gray painted
finish.
Boxes are code-gauge
galvanized steel without
knockouts. Standard depth is
5.75 inches (146.1 mm).
Standard width is 20.00-inch
(508.0 mm) 100–400A.
Volume 2—Commercial Distribution CA08100003E—December 2010
Top and Bottom Gutters
5.50 inches (139.7 mm)
minimum.
Side Gutters
4.00 inches (101.6 mm)
minimum.
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
PRC100EC Panelboard
10.6
Contents
Description
Page
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
447
451
453
454
457
460
463
468
469
478
470
473
An Eaton
Green Solution
10
10
10
10
10
10
10
10
10
10
PRC100EC Panelboard
10
Product Description
10
Eaton’s Pow-R-Command
PRC100 panelboard may be
ordered with an optional
factory-installed Expansion
Chassis in addition to the
factory-installed Universal
System Controller. The
optional Expansion Chassis
houses up to two PRC100
Application Specific Controllers
(ASC) that may be field
installed. The addition of the
optional Expansion Chassis
and Application Specific
Controllers to the standard
PRC100 panelboard will
extend the functionality of
the PRC100 panelboard
beyond time-of-day power
switching.
10
10
10
10
10
10
10
10
10
Branch Breakers
●
Refer to Page 465
10
10
Application Specific Controllers
(ASC)
●
10
Select up to two ASCs per
panel from Page 475
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
467
10.6
10
10
Panelboards and Lighting Control
Pow-R-Command
Product Selection
Type PRC100EC
10
Ampere
Rating
10
Main Integral Fuse Disconnect—Series Rated Combinations PRC100EC Panelboard
Interrupting Rating (kA Symmetrical)
Device
240V
480Y/277V
Type
Main Lug Only 10
100
—
—
MLO
250
—
—
MLO
10
400
—
—
MLO
100
18
14
EHD
10
100
18
14
FDB
100
65
35
FD
10
100
100
65
HFD
100
200
100
FDC
100
200
150
FCL
10
200
200
FB-P
225
22
—
EDB
10
225
42
—
EDS
225
65
—
ED
10
225
100
—
EDH
225
200
—
EDC
225
65
35
FD
10
225
100
65
HFD
225
200
100
FDC
10
250
65
35
JD
250
100
65
HJD
10
250
200
100
JDC
400
65
—
DK 400
65
35
KD 400
100
65
HKD 400
200
100
KDC 10
10
10
100
100
200
65
Device
Type
Approved Branch
Devices
100
T Fuse
Disconnect GHB, GHBS,
EHD, FDB, FD
65
T Fuse
Disconnect GHB, GHBS,
EHD, FDB, FD
Includes Smart Chassis (system controller integral to the panelboard chassis).
100
10
Interrupting Rating
(kA Symmetrical)
240V
480Y/277V
Notes
The short-circuit rating of the MLO assembled panelboard may be fully rated based upon
the lowest rated branch breaker or series rated with an approved upstream device.
The short-circuit rating shown is that of the main breaker only. The rating of the assembled
panelboard is the same as the short-circuit rating of the lowest rated main or branch device.
Top feed only.
The short-circuit rating shown is the rating of the panelboard assembly with the main and
approved branch devices as listed.
Fuses not included.
Main Breaker 10
Ampere
Rating
Lighting optimization software and startup support must be included with each
system—see Page 475.
10
10
10
10
10
10
10
10
10
10
10
468
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
10.6
Panelboards and Lighting Control
Pow-R-Command
Panel Layout
Pow-R-Command PRC100EC Layout
1-Pole 1-Pole 1X
EHD
2-Pole 2-Pole 2X
FDB
FD
3X
HFD
FDC
2X
EDB, EDS, ED, EDH EDC
3X
EDB, EDS, ED, EDH, EDC
1-Pole
3-Pole
2-Pole 2-Pole 3-Pole BABRP
BABRSP
BAB
GHQRSP
GHBS
GHB
5X
12 Poles
10X
24 Poles
ckt
2
4
6
8
10
12
14
16
18
ckt
1
3
5
7
9
11
13
15
17
Pow-R-Command
Smart Chassis and
18 Pole Spaces
Expansion
Chassis
Accepts
1 Application
Specific
Controller
20X
Smart Chassis
includes spaces
for 18 Poles
GHBS, GHQRSP, GHB, BABRP, BABRSP, BAB
Instructions
1. Select: (from layout
on left)
a. Smart Chassis with
Expansion Chassis.
Layout Example
1. Panel description:
a. Pow-R-Command,
three-phase, four-wire
480Y/277 Vac,
interrupting rating of
14 kAIC symmetrical,
250A main lugs only at
bottom, surface
mounted and the
following branch
breakers:
b. 36–20A, single-pole
GHBS.
c. 6–20A, single-pole
GHBS spaces.
Note: Smart chassis is always
located at the bottom of the
panelboard chassis immediately
below the bottom breaker.
b. Required mains (lugs,
breaker or fuse
pullout).
c. Appropriate neutral.
d. Branch breakers and
additional chassis
space, as needed.
2. Layout information from
layout on left:
a. Smart Chassis
with EC . . . . . . = 20X
b. 24-circuit add-on
chassis . . . . . . = 10X
c. 250A neutral . . = 5X
d. 250A main
lugs only . . . . . = 5X
e. Total panelboard
height . . . . . . . = 40X
2. Layout panel as shown
on left, using appropriate
“X” units. Total “X” units
determine box height
shown on left. (When
total “X” units exceeds
the number shown, use
next size box size.)
Smart Chassis is
always located at the
bottom of the
panelboard chassis
immediately below all GHBS/GHB or BABR/
BABRS/BAB breakers.
Neutral Section
5X
8X
100–250 A
400 A
Main Lug Section
2X
5X
8X
100 A
250 A
400 A
3. From table below:
(40X box)
Box catalog
number . . . . . . . YS2072
Trim catalog
number . . . . . . LT2072S
OR
Box catalog
number . . . . . EZB2072R
Trim catalog
number . . . . . EZT2072S
See branch mounted —
EHD, FD, FDB, HFD, FDC, EDB, EDS, ED,
EDH, EDC above
Main Devices
Vertically Mounted
7X—EHD, FDB, FD,
HFD, FDC, EDB, EDS, ED, EDH, EDC
7X—100 A
Class T fusible pullout
9X—200 A
Class T fusible pullout
9X—FB-P 14X—JD, HJD, JDC
15X—DK, KD, HKD,
KDC Notes
All F-Frame branch breakers must be mounted above (top) of all controllable breakers on the
chassis.
EDB, EDS, ED, EDH and EDC branch mounted breakers may be mounted with load lugs on either
left or right. Specify on order.
All add-on branch spaces must be adjacent to smart chassis poles.
GHBS, GHQRSP and GHB breakers cannot be mixed on same chassis with BABRP, BABRSP and
BAB breakers.
Top mounted main—only.
Box
Height
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Box Tabulation
“X”
Units
10
10
Approximate Dimensions in Inches (mm)
Main Device
Horizontally Mounted
10
YS Box
Catalog
Number
LT Trim
Catalog
Number
EZ Box
Catalog
Number
EZ Trim
Catalog
Number
10
10
100–400A
23X
48.00 (1219.2)
YS2048
LT2048S or F
EZB2048R
EZT2048S or F
31X
60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
40X
72.00 (1828.8)
YS2072
LT2072S or F
EZB2072R
EZT2072S or F
53X
90.00 (2286.0)
YS2090
LT2090S or F
EZB2090R
EZT2090S or F
Cabinets
Fronts are code-gauge steel,
ANSI-61 light gray painted
finish.
Boxes are code-gauge
galvanized steel without
knockouts. Standard depth
is 5.75 inches (146.1 mm).
Standard width is 20.00-inch
(508.0 mm) 100–400 amperes.
Volume 2—Commercial Distribution CA08100003E—December 2010
Top and Bottom Gutters
5.50 inches (139.7 mm)
minimum.
10
10
10
10
10
Side Gutters
4.00 inches (101.6 mm)
minimum.
10
10
10
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
469
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Contents
PRC50 Panelboard
Description
10
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10
10
10
10
10
10
Page
447
451
453
454
457
460
463
467
471
478
473
An Eaton
Green Solution
10
10
10
PRC50 Panelboard
10
Product Description
10
10
10
10
10
10
10
10
10
10
Eaton’s PRC50 panelboard
is similar to a PRC100
panelboard with additional
programming capability
added that provides the ability
to group up to 42 remotely
operated circuit breakers into
eight individual zones. Each
zone is designed to be
switched by a dry contact
from an external time clock,
switch or interposing relay.
The PRC50 programming board
included with the controller
allows the breakers to be
grouped locally without the
need of special equipment or
software. The groupings can be
easily changed without the
need of any field rewiring.
The grouping configurations
are made using simple
pushbutton inputs.
Service
120/240 Vac single-phase
three-wire, 208Y/120 Vac
three-phase four-wire
●
240/120 Vac three-phase
four-wire, 480Y/277 Vac
three-phase four-wire
●
Zone Configuration
Eight Zones of Event
Driven Control
●
Simple two key field
programming
●
Matrix wiring allows
breakers to be assigned to
multiple zones
●
Eight integrated digital
override inputs
●
No analog inputs
●
Branch Breakers
Refer to Page 472
●
10
10
10
10
10
10
10
10
470
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
Product Selection
Type PRC100
10
PRC50 Panelboard
Ampere
Rating
Main Integral Fuse Disconnect—Series Rated Combinations
Interrupting Rating (kA Symmetrical)
Device
240V
480Y/277V
Type
Main Lug Only 100
—
—
MLO
250
—
—
MLO
400
—
—
MLO
Main Breaker 100
18
14
EHD
100
18
14
FDB
100
65
35
FD
100
100
65
HFD
100
200
100
FDC
100
200
150
FCL
100
200
200
FB-P 225
22
—
EDB
225
42
—
EDS
225
65
—
ED
225
100
—
EDH
225
200
—
EDC
225
65
35
FD
225
100
65
HFD
225
200
100
FDC
250
65
35
JD
250
100
65
HJD
250
200
100
JDC
400
65
—
DK
400
65
35
KD
400
100
65
HKD
400
200
100
KDC
400
200
100
LCL Ampere
Rating
Interrupting Rating
(kA Symmetrical)
240V
480Y/277V
100
100
200
65
Device
Type
Approved Branch
Devices
100
T Fuse
Disconnect GHB, GHBS,
EHD, FDB, FD
65
T Fuse
Disconnect GHB, GHBS,
EHD, FDB, FD
10
10
10
10
Notes
The short-circuit rating of the MLO assembled panelboard may be fully rated based upon
the lowest rated branch breaker or series rated with an approved upstream device.
The short-circuit rating shown is that of the main breaker only. The rating of the assembled
panelboard is the same as the short-circuit rating of the lowest rated main or branch device.
Top feed only.
Requires 6.50-inch (165.1 mm) deep box.
The short-circuit rating shown is the rating of the panelboard assembly with the main and
approved branch devices as listed.
Fuses not included.
Includes Pow-R-Command Universal System Controller integral to the panelboard chassis (Smart
Chassis) and the PRC50 Programming Board. Lighting optimization software and start-up support
are not required.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
471
10.6
10
BABRP Remote Control
Circuit Breaker
Pow-R-Command
Branch Circuit Breakers—480Y/277 Volt Maximum
Ampere Rating
10
Interrupting Rating (kA Symmetrical)
240 Volt
480 Volt
Breaker Type
Remote Controllable Branch Circuit Breakers
10
10
10
10
Panelboards and Lighting Control
15–30
10
—
BABRP 15–30
10
—
BABRSP 15–20
65
14
GHQRSP 15–30
65
14
GHBS Conventional Branch Circuit Breakers—Not Controllable
GHBS Remote Control
Circuit Breaker
10
10
15–60
10
—
BAB 15–60
10
—
BAB-H
70
10
—
BAB 70
10
—
BAB-H
80–100
10
—
BAB 80–100
10
—
BAB-H
15–50 10
—
QBGF 15–50 10
—
QBGFEP 15–20
10
—
QBCAF 10
15–20
65
14
GHQ 15–20
65
14
GHB 10
25–60
65
14
GHB 70–100
65
14
GHB 15–60
18
14
EHD
10
10
10
70–100
18
14
EHD
15–60
18
14
FDB
70–100
18
14
FDB
110–150
18
14
FDB
10
15–60
65
35
FD 70–100
65
35
FD 10
110–225
65
35
FD
15–60
100
65
HFD 10
70–100
100
65
HFD 110–225
100
65
HFD
15–60
200
100
FDC
70–100
200
100
FDC
110–225
200
100
FDC
10
100–225
22
—
EDB
100–225
42
—
EDS
10
100–225
65
—
ED 100–225
100
—
EDH 10
100–225
200
—
EDC 10
10
10
10
Notes
Single-pole breaker rated 120 Vac. Two-pole breaker rated 120/240 Vac.
Single-pole breakers are rated 277 Vac maximum. Two- and three-pole breakers are rated 480Y/277 Vac maximum.
50A devices are available as two-pole only.
GFCI for 5 mA personnel protection.
GFP for 30 mA equipment protection.
Arc fault circuit breaker.
For use on 480Y/277 Vac maximum.
Maximum lug size, 4/0 AWG Al/Cu in 20-inch (508.0 mm) wide box. 300 kcmil lug available in 28-inch (711.2 mm) wide box.
10
10
10
10
10
10
10
472
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
10.6
Panelboards and Lighting Control
Pow-R-Command
Contents
PRC25 Panelboard
Description
Page
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pow-R-Command 4000 (PRC4000) . . . . . . . . . . . . . . . . . . .
Pow-R-Command 2000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 1000 Panelboard . . . . . . . . . . . . . . . . . . .
Pow-R-Command 750 Panelboard . . . . . . . . . . . . . . . . . . . .
PRC100 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC100EC Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC50 Panelboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRC25 Panelboard
Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
447
451
453
454
457
460
463
467
470
474
478
10
10
10
10
10
10
10
10
10
10
10
PRC25 Panelboard
10
Product Description
The PRC25 panelboard is
designed to meet the needs
for control of lighting and
small branch circuits. Used as
a standalone panelboard
controlled by a time clock or
wall switch, the PRC25 offers
a solution for replacement of
contactor and relay-based
lighting control schemes. It
can be applied to distribution
systems rated:
●
●
Single-phase three-wire and
three-phase four-wire
120/240, 208Y/120 and
480Y/277 Vac
to group individual breakers
into zones that may be
switched on/off by a dry
contact from a time clock,
photocell, wall switch or
building automation system.
Branch Breakers—PRC25
10
Ampere
Rating
Interrupting Rating
(kA Symmetrical)
480Y/277 Vac
Breaker
Type
15–20
14
GHQ
15–20
14
GHB
Branch Breakers
Refer to Page 478.
25–60
14
GHB
70–100
14
GHB
Standards and Certifications
15–30
25
HGHB
15–20
14
GHQRSP 15–60
14
GHBGFEP 15–20
14
GHBHID Provision
—
—
●
●
●
UL 67, UL 50
Federal Specification
W-P-115c
Refer to Page 463 for
additional information
10
10
10
10
10
10
10
Notes
Single-pole breakers are rated 120 Vac maximum.
50 ampere devices are available as two-pole only.
GFCI for 5 mA personnel protection.
GFP for 30 mA equipment protection.
Arc fault circuit breaker.
HID (High Intensity Discharge) rated breaker.
Switching neutral breaker. Single-pole device requires two-pole space; two-pole device
requires three-pole space.
Solenoid operated breaker.
The heart of the PRC25 panel
is the Zoning Board integral to
the panelboard. This
controller provides the ability
Product Selection
Branch Circuit Breakers—PRC25
Ampere
Rating
Interrupting Rating
(kA Symmetrical)
240 Vac Breaker
Type
15–60
70
80–100
15–50 15–50 15–20
15–60
15–30
15–30
15–30
10
10
10
10
10
10
10
10
10
10
BAB
BAB
BAB
QBGF QBGFEP QBCAF BAB-D BAB-C BABRP BABRSP Provision
—
—
Volume 2—Commercial Distribution CA08100003E—December 2010
10
10
10
10
10
10
10
10
10
10
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
473
10.6
10
Panel Layout
10
PRC25 Layout
10
ckt
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
ckt
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
10
10
10
10
10
10
10
31 in. - Includes Class II Chassis and spaces
for 42 poles
Note: PRC25 Chassis may be located
at the Top or Bottom of the
panelboard immediately above or
below the breakers.
Instructions
1. Select PRC25
Panelboard Chassis from
layout on left.
Layout Example
1. Panel Description:
a. PRC25, three-phase
four-wire, 208Y/120
Vac, interrupting
rating of 10 kAIC
symmetrical:
225A main lugs only
at bottom, surface
mounted and the
following branch
breakers
b. 36–20A, single-pole
BABRP
c. 6–20A, single-pole
BABRP spaces
2. Layout information from
layout on left.
a. Determine required
mains (lugs or
breaker)
b. Select appropriate
main lug
c. Select appropriate
main device
d. Select appropriate
branch breakers
2. Layout panel as shown
on left. Total inches
determine box height
shown on left. (When
total inch units exceed
the number shown, use
next size box size.)
a. PRC25 with 42-circuit
Interior 31 inches
b. 225A main lugs
Section 4 inches
c. Total panelboard
height 35 inches
3. From table below:
PRC25
Class II
Chassis
10
10
Pow-R-Command
Note: Controlled circuits must be grouped in maximum of 6 Zones.
All circuits within a zone must be together on the same side of the
panelboard.
10
10
Panelboards and Lighting Control
Deadfront Cover
2 in. for Deadfront
Cover Supports
Main Lug Section
2 in.—100 Amp MLO
4 in.—225 Amp MLO
21 in.—400 Amp MLO
10
Vertically Mounted
10
●
●
8 in.—100 Ampere Frame EHD, EDB, EDS, ED,
EDH, FD, HFD
●
9 in.—225 Ampere Frame EDB, EDS, ED, EDH,
FD, HFD, FDC
10
●
24 in.—JD, HJD, JDC
10
24 in.—DK, KD, HKD, KDC
10
Panel height:
20 inches wide x 5.75
inches deep
Box height: 35 inches
60 inches
Box catalog number:
YS2060 or EZB2060R
Trim catalog number:
LT2060S or EZT2060S
Approximate Dimensions in Inches (mm)
Box Tabulation
10
“X”
Units
10
Box
Height
YS Box
Catalog
Number
LT Trim
Catalog
Number
EZ Box
Catalog
Number
EZ Trim
Catalog
Number
20-Inch Wide x 5.75-Inch Deep Boxes
10
33.00 (838.2)
48.00 (1219.2)
YS2048
LT2048S or F
EZB2048R
EZT2048S or F
35.00 (889.0)
60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
10
38.00 (965.2)
60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
40.00 (1016.0) 60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
44.00 (1117.6) 60.00 (1524.0)
YS2060
LT2060S or F
EZB2060R
EZT2060S or F
55.00 (1397.0) 72.00 (1828.8)
YS2072
LT2072S or F
EZB2072R
EZT2072S or F
10
10
Cabinets
Trims are code gauge steel,
ANSI 61 light gray painted
finish. Boxes are code gauge
galvanized steel without
knockout. Standard size is
20.00 inches (508.0 mm)
wide x 5.75 inches
(146.1 mm) deep.
10
10
10
10
Top and Bottom Gutters
6.38 inches (162.1 mm).
Minimum Side Gutters
4.00-inch (101.6 mm)
minimum on 20.00-inch
(508.0 mm) wide box size.
10
474
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
PRC Catalog Numbers
Description
10
Catalog Number 10
Control Cabinet—With Power Supply, System Controller and Space for Up to Three ASCs
Control cabinet—surface mount
PRC100CCS
Control cabinet—flush mount
PRC100CCF
GHBS pigtail cable—8 feet (2.4m)
PRL100ECP
GHBS pigtail cable—16 feet (4.9m)
PRC100ECP-16
GHBS pigtail cable—24 feet (7.3m)
PRC100ECP-24
GHBS pigtail cable—32 feet (9.8m)
PRC100ECP-32
10
10
10
10
Controllers
208V PRC2000 Controller—LCD display
PRC2000D-208
480V PRC2000 Controller—LCD display
PRC2000D-480
240V PRC2000 Controller—LCD display
PRC2000D-240
208V PRC2000 Controller
PRC2000-208
480V PRC2000 Controller
PRC2000-480
240V PRC2000 Controller
PRC2000-240
208V PRC1000 Controller—LCD display
PRC1000D-208
480V PRC1000 Controller—LCD display
PRC1000D-480
240V PRC1000 Controller—LCD display
PRC1000D-240
208V PRC1000 Controller
PRC1000-208
480V PRC1000 Controller
PRC1000-480
240V PRC1000 Controller
PRC1000-240
208V PRC750 Controller—LCD display
PRC750D-208
480V PRC750 Controller—LCD display
PRC750D-480
240V PRC2000 Controller—LCD display
PRC750D-240
10
120V PRC2000 External Controller—LCD display
PRC2000ECD-120
10
120V PRC2000 External Controller
PRC2000EC-120
277V PRC2000 External Controller—LCD display
PRC2000ECD-277
277V PRC2000 External Controller
PRC2000EC-277
120V PRC1000 External Controller—LCD display
PRC1000ECD-120
120V PRC1000 External Controller
PRC1000EC-120
277V PRC1000 External Controller—LCD display
PRC1000ECD-277
277V PRC1000 External Controller
PRC1000EC-277
120V PRC750 External Controller—LCD display
PRC750ECD-120
277V PRC750 External Controller—LCD display
PRC750ECD-277
10
10
10
10
10
10
10
10
External Controller
10
10
10
10
10
10
Note
All catalog numbers are non-standard items.
10
10
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
475
10.6
10
10
Panelboards and Lighting Control
Pow-R-Command
PRC Catalog Numbers, continued
Catalog Number Description
Advanced Control Devices
PRC Digital Network Switch 2-button (Black)
PRCDS2B
PRC Digital Network Switch 2-button (White)
PRCDS2W
10
PRC Digital Network Switch 2-button (Almond)
PRCDS2A
PRC Digital Network Switch 4-button (Black)
PRCDS4B
10
PRC Digital Network Switch 4-button (White)
PRCDS4W
PRC Digital Network Switch 4-button (Almond)
PRCDS4A
PRC Digital Network Switch 6-button (Black)
PRCDS6B
10
PRC Digital Network Switch 6-button (White)
PRCDS6W
PRC Digital Network Switch 6-button (Almond)
PRCDS6A
10
PRC Digital Switch Network Power Injector
PRCDSNPI
PRC Digital Switch Network Splitter
PRCDSNSP
PRC 2-button Momentary Low Voltage Switch (Black)
PRCLS2B
10
PRC 2-button Momentary Low Voltage Switch (White)
PRCLS2W
PRC 2-button Momentary Low Voltage Switch (Almond)
PRCLS2A
10
PRC 4-button Momentary Low Voltage Switch (Black)
PRCLS4B
PRC 4-button Momentary Low Voltage Switch (White)
PRCLS4W
PRC 4-button Momentary Low Voltage Switch (Almond)
PRCLS4A
10
PRC 6-button Momentary Low Voltage Switch (Black)
PRCLS6B
PRC 6-button Momentary Low Voltage Switch (White)
PRCLS6W
10
PRC 6-button Momentary Low Voltage Switch (Almond)
PRCLS6A
10
10
10
10
10
Wireless Control Devices
PRC4000 Wireless Small Building Controller
PRC4000-W
10
PRC4000 Wireless Extended Range Small Building Controller
PRC4000-WX
PRC Wireless I/O Module Assembly
PRCWIOM
10
PRC Wireless Switch Interface
PRCWSI
PRC Wireless Network Switch 2-button (Black)
PRCWS2B
PRC Wireless Network Switch 2-button (White)
PRCWS2W
10
PRC Wireless Network Switch 2-button (Almond)
PRCWS2A
PRC Wireless Network Switch 4-button (Black)
PRCWS4B
10
PRC Wireless Network Switch 4-button (White)
PRCWS4W
PRC Wireless Network Switch 4-button (Almond)
PRCWS4A
PRC Wireless Network Switch 6-button (Black)
PRCWS6B
10
PRC Wireless Network Switch 6-button (White)
PRCWS6W
PRC Wireless Network Switch 6-button (Almond)
PRCWS6A
10
PRC25
10
10
10
10
6-zone PRC25 Maintained to Momentary Controller
PRC25-6
4-zone PRC25 Maintained to Momentary Controller
PRC25-4
Note
All catalog numbers are non-standard items.
10
10
10
10
10
476
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Panelboards and Lighting Control
Pow-R-Command
10.6
PRC Catalog Numbers, continued
10
Catalog Number Description
10
Optional Equipment
LCD Display unit for PRC1000/2000
PRCLCD
Breaker Control Bus—21-circuit—Retrofit Kit
PRCBCB-21R
Breaker Control Bus—15-circuit—Retrofit Kit
PRCBCB-15R
Breaker Control Bus— 9-circuit—Retrofit Kit
PRCBCB-9R
Breaker Control Bus—21-circuit
PRCBCB-21
Breaker Control Bus—15-circuit
PRCBCB-15
Breaker Control Bus—9-circuit
PRCBCB-9
24 Volt AC Power supply
PRCPS24
10
Switch override controller
PRC100SOC
Telephone override controller
PRC100TOC
10
PRC100 universal system controller
PRC100USC
PRC50 programming board
PRC50SPB
Native Modbus controller
PRC100MOD
JCI Metasys controller
PCR100JCI
10
10
10
10
Application Specific Controllers (ASC)
10
10
10
Computers and Peripherals
Network interface box
PRC100NIB
Ethernet terminal server
PRC100ENS
Smart programming cable (serial)
PRCSMARTCABLE
Modbus programming cable (serial)
MPC-S
Laptop computer
PRC100LTC
Central operator’s station
PRC100COS
Data logging printer
PRC100DLP
Data fax modem—56K
PRC100DFM
10
10
10
10
Software
10
Lighting optimization software PRC100SLO
Web server software with hardware server key
PRC100SWS
Building graphics software with PC hardware key
PRC100SBG
Custom graphics screens programming PRC100SCG
10
Startup, training and/or programming first day of trip (includes expenses) PRC100SUT1
10
Additional consecutive days of same trip PRC100SUT2
Additional user’s guide PRC100UG
10
Technical Support
10
10
Notes
All catalog numbers are non-standard items.
One software package required per system.
One day required per system (up to six panels).
Required to start up six panels per day after the first day.
One user’s guide included with each system at no charge.
10
10
10
10
10
10
10
10
10
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
477
10.6
10
Panelboards and Lighting Control
Pow-R-Command
Modifications
1. Special Cabinet (Box) Construction
8. Trim and Door Modifications —Special Fronts and Doors
Modification 1
Modification 8
Modification
Description
Type 1 Enclosure
Door-in-door, one door over interior and one which exposes gutter (LT Trim)
28-inch (711.2 mm) wide in place of standard 20-inch (508.0 mm) wide
Common LT trim for two section panels with boxes bolted together
10
Type 2 Enclosure
Standard flush lock with quarter turn fasteners at top and bottom of trim door (standard on
doors 48-inch (1219.2 mm) high and over) (LT Trim)
10
Type 3R Enclosure
10
10
10
10
10
10
10
10
10
10
10
10
(Drip-proof with gasketed trim)
(20-inch (508 mm) wide)
(28-inch (711.2 mm) wide)
9. Special Hinges—LT Trim
Piano hinges in lieu of standard hinges.
Type 12 Enclosure
Modification 9
(20-inch (508 mm) wide)
(28-inch (711.2 mm) wide)
Description
Add for each panel door
2. Complete Assembly
Complete assembly of panelboard box, interior and trim prior to
shipment when required.
10. Special Locks
Modification 2
Description
Description
LT Type Trim
Add per panel
Yale 511S with rosette
Yale 4651S (LL803 Key)
Master keying—above locks or standard lock—per panelboard
3. Concealed Trim Clamps—LT Trim
10
Tee handle and 3-point catch
Modification 3
National metal lock with standard keying
Description
National metal lock with GE75 keyway
Add per panel
EZ Trim
10
10
Modification 10
Standard lock, keyed GE75
4. Nameplate, Engraved
Standard lock, keyed to Corbin TEU-1
Modification 4
Standard lock, keyed to Corbin Cat 60
Type
Standard lock, keyed to Corbin WEM1
Mastic back and installed by purchaser, per nameplate
10
Fixed to panel trim with two screws or rivets, per nameplate
10
5. Directory Frame—Metal
10
Modification 5
Modification 11
Cover Type
Frame Type
10
11. Conduit Covers
Fabricated sheet metal to cover open conduits above and/or
below standard NEMA Type 1 box.
Metal frame, plastic cover
Conduit enclosing shield (open back)
Conduit enclosure (solid back)
10
6. Permanent Circuit Numbers
10
Modification 6
12. Increased Dimensions
Modification 12
Description
10
To provide permanently attached Micarta circuit numbers
10
7. Tamperproof Screws—LT Trim
10
Modification 7
Description
Increased End Gutters
7-inch (177.8 mm) top or bottom
12-inch (304.8 mm) top or bottom
Description
10
4-inch (101.6 mm) top or bottom
Increased Side Gutters
Tamperproof screws for trims, in lieu of standard screws
10
4-inch (101.6 mm) left or right
7-inch (177.8 mm) left or right
12-inch (304.8 mm) left or right
10
478
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
10.6
Panelboards and Lighting Control
Pow-R-Command
13. Painting and Special Coatings
Standard boxes are code-gauge galvanized sheet steel. Standard
trims are code-gauge sheet steel with a rust inhibiting
phosphatized coating and finished with ANSI-61.
16. Bus Density
Main bus ampere rating is determined by UL listed temperature
test. For 750 ampere per square inch aluminum or 1000 ampere
per square inch copper, make price addition as follows:
Modification 13
Modification 16
Description
Amperes Per Square Inch
Painted boxes (ANSI-61)
Aluminum—750A
Painted trims or boxes (other than ANSI-61)
250A Maximum
10
10
10
10
10
400A Maximum
14. Copper Main Bus
Copper—1000A
Modification 14
250A Maximum
Main Bus Ratings Amperes
400A Maximum
100
Note: Modification 14—Applies to 310 and 310+ Trip Units.
10
17. Neutral Rated 200%
10
10
10
225–250
400
Modification 17
14a. Silver-Plated Copper Main Bus
For silver-plated copper panelboard main bus and/or connectors,
add as follows:
Main Bus Rating Amperes
Neutral Rating Amperes
Box Height Addition
100
225
0
225
450
0
Modification 14a
250
500
3X
Main Bus Ratings Amperes
400
800
3X
100–250
10
10
10
Note: Prices and dimensions based on mechanical lugs. For compression
or copper lugs, refer to Eaton.
400
14b. Tin-Plated Copper Main Bus
For tin-plated copper panelboard main bus and/or connectors,
add as follows:
18. Increased Panel Main Bus Rating
10
100–250
Main Bus Ratings Amperes
10
250–400
100–250
400–600
10
19. Compression Main Lugs—Type Burndy Range Taking Al/Cu
Compression Terminations
For other terminal types, refer to Eaton.
10
400
15. Ground Bar
Modification 15
Aluminum Terminal Bar for
Aluminum or Copper Cable
Standard
Insulated/
Isolated Copper Terminal Bar
for Copper Cable Only
Standard
Insulated/
Isolated 10
10
Modification 18
Ampere Rating Change
Modification 14b
10
10
Modification 19
10
Wire Range by Panel Type
Main
Ampere PRL1a and PRL2a PRL3E
PRL3a
PRL4
100
(1) #1–1/0 or
(1) 2/0–300 kcmil
—
—
—
125
—
(1) #4–2/0 or
(1) 2/0 –300 kcmil
(1) #4–2/0 or
(1) 2/0–300 kcmil
—
225
(1) 2/0–300 kcmil or —
(1) 4/0–500 kcmil
—
—
250
—
400
(2) 4/0–300 kcmil or (2) 4/0–300 kcmil or (2) 4/0–300 kcmil or (2) 500–750 kcmil
(2) 500–750 kcmil (2) 500–750 kcmil (2) 500–750 kcmil
600
—
(2) 2/0–500 kcmil or (2) 2/0–500 kcmil or (2) 500–750 kcmil
(2) 500–750 kcmil (2) 500–750 kcmil
10
800
—
—
—
(3) 500–750 kcmil
1200
—
—
—
(4) #2–600 kcmil or
(4) 500–750 kcmil
10
10
10
10
(1) 2/0 –350 kcmil or (1) 2/0–350 kcmil or (2) 500–750 kcmil
(1) 4/0–500 kcmil (1)–4/0–500 kcmil
Note
Insulated/isolated ground bar includes a standard ground bar.
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
10
10
10
10
479
10.6
10
10
10
Panelboards and Lighting Control
Pow-R-Command
20. Copper Lugs
Optional copper mechanical main lugs only. (Includes main
incoming neutral lug.)
25. Circuit Breaker Handle Lockoff Devices
Modification 25
Breaker Type
Modification 20
Non-Padlockable
Main Amperes
Wire Range and Number of Lugs Per Phase
GHB, EHD, FDB, FD, ED, EDH, EDC, BAB
10
100
(1) #14–1/0
Padlockable
225–250
(1) #6–250 kcmil
EHD, FDB, FD, HFD, FDC, ED, EDH, EDC, GHB, BAB
10
400
(2) #1/0–600 kcmil
10
10
21. Sub-Feed Lugs—PRC100 and PRC50 Only
Mechanical Al/Cu lugs. Compression or copper lugs requires
additional price adder from Modification 19 or Modification 20
as appropriate.
10
Available on main lug panels only.
10
Modification 21
10
10
10
10
10
10
10
10
10
10
10
10
Main Amperes
Box Height Addition
100–250
1X
Terminal Material
Wire Range
F
225
Copper
#4–4/0
J
250
Stainless Steel
#4–350
K
225
Copper
(1)#3–350
350
Copper
(1)250–500
400
Copper
(2)3/0–250
Description
Main Amperes
Box Height Addition
100
2X
250
5X
400
8X
23. Service Entrance
To provide a Service Entrance label as detailed under the
“Service Entrance Equipment” in application considerations.
Only panelboards meeting these requirements can be labeled as
such. The requirement for a Service Entrance Label must be
noted on order entry. Includes neutral disconnect link and
Service Entrance Equipment Label. (Ground bar not included—
see Modification 15.)
Modification 27
12 oz. Spray Can. ANSI-61
Light Gray Indoor
Case lot of 12—12 oz. spray cans. ANSI-61 light gray indoor
Single style
Note
BAB breakers with shunt trips require one additional pole space, i.e., three-pole breaker with
shunt trip requires four-pole space.
Modification 23
Device
24. Shunt Trip for Main or Branch Circuit Breaker
For tripping circuit breaker from a remote point. Voltage and
frequency must be specified. Wiring to terminal blocks is not
included. Standard leads extend 18 inches (457.2 mm) out
of breaker.
Circuit breakers with factory-installed 120, 240 or 480 Vac shunt
trips are available with UL listing as shown in table below.
10
Modification 24
10
GHB (three-pole only)
10
Max. Breaker
Ampere Rating
Modification 22
10
10
Frame
27. Touchup Paint
Add per panel
10
Modification 26
22. Through-Feed Lugs
Mechanical Al/Cu lugs. Compression or copper lugs requires
additional price adder from Modification 19 or Modification 20
as appropriate.
10
10
26. Copper Wire Only Terminals for Molded Case Circuit Breakers
(To replace standard Al/Cu terminals)
Device
All other circuit breakers 10
480
Volume 2—Commercial Distribution CA08100003E—December 2010
www.eaton.com
For Immediate Delivery or Tech Support call KMParts.com at (866) 595-9616
Index
A
ability, 2-3, 7-8, 11, 14-15, 24, 27
above, 3, 20, 23, 28, 32
AC, 31
ac, 27
Accepts, 23
Access, 4, 9, 12
access, 1, 3-5, 7, 9
accessories, 3
AccessTCP, 6
accommodate, 7
accomplish, 4
achieve, 2, 7
across, 6
act, 7
Add, 32, 34
add, 20, 23, 33
added, 3, 24
adder, 34
Addition, 33-34
addition, 2-3, 7, 21, 33
Additional, 31
additional, 2-3, 6, 17, 20, 23-24, 27, 34
address, 9
adds, 2, 7-8
adjacent, 1, 20, 23
adjustable, 3
adjusts, 7
Advanced, 2, 30
advanced, 2, 7
after, 31
aid, 3
airports, 2, 15
Al, 19, 26, 33-34
alarm, 2-3, 7, 15
Alarms, 3
alarms, 8, 11, 14
All, 4, 7, 20, 23, 28-31, 34
all, 1-3, 12, 15, 20, 23
allow, 1-2, 4, 12
allowing, 1
Allows, 4
allows, 1, 3-4, 7-8, 11, 14, 24
Almond, 2, 30
almost, 1
already, 7
Also, 3
also, 2-3, 7-8, 11, 14-15, 17
Although, 1
Aluminum, 33
aluminum, 33
always, 20, 23
Amp, 10, 13, 16, 28
Ampere, 10, 13, 16, 18-19, 22, 25-28, 33-34
ampere, 27, 33
Amperes, 33-34
amperes, 23
An, 1, 7-8, 11, 14, 17, 21, 24
an, 1-4, 7-9, 11, 14, 18, 21-22, 24-25
Analog, 5
analog, 4-5, 7, 24
and, 1-34
ANSI, 10, 13, 16, 20, 23, 28, 33-34
any, 3-4, 7, 9, 15, 24
anywhere, 9
Index
Application, 3-4, 8, 11-12, 17, 21, 23, 31
application, 3, 34
Applications, 1, 4
applications, 1-4, 8, 11, 14-15, 17
applied, 1, 17, 27
Applies, 33
Appropriate, 20, 23
appropriate, 10, 13, 16, 20, 23, 28, 34
Approved, 18, 22, 25
approved, 18, 22, 25
Approximate, 10, 13, 16, 20, 23, 28
APRC, 30
Arc, 19, 26-27
Architecture, 9, 15
are, 1-4, 7-11, 13-14, 16, 19-20, 23-31, 33-34
around, 2
array, 7
art, 2, 7
Article, 1
as, 1-4, 7-14, 16-20, 22-23, 25-28, 33-34
ASC, 3, 21, 31
ASCII, 6
ASCs, 3-4, 8, 11, 21, 29
assembled, 18, 22, 25
Assembly, 30, 32
assembly, 18, 22, 25, 32
assigned, 24
assistance, 2
associated, 2
Astronomical, 3, 8, 11, 14
astronomical, 2, 7, 15
at, 1-34
attached, 32
auditoriums, 3
automated, 2, 7
Automation, 2
automation, 1, 3, 8, 27
auxiliary, 7
Available, 4, 8, 11, 14, 34
available, 1-4, 6, 17, 19, 26-27, 34
AWG, 19, 26
B
BAB, 19-20, 23, 26-27, 34
BABR, 20, 23
BABRP, 19-20, 23, 26-28
BABRS, 20, 23
BABRSP, 8, 10-11, 13-14, 16, 19-20, 23, 26-27
back, 1-2, 7, 32
backed, 7
backup, 6
BACnet, 2, 5-6, 8-9
ballasts, 2, 6-7
Bar, 33
bar, 33-34
BAS, 1
based, 1-2, 4, 7-8, 11, 14-15, 17-18, 22, 25, 27, 33
Basic, 2
basic, 3
basis, 2
Battery, 6
battery, 7
Baud, 6
BCB, 3, 9, 12, 15
BCBs, 3, 9, 12, 15
be, 1-5, 7-18, 20-25, 27-28, 34
Because, 2
Being, 2
being, 2-3
below, 10, 13, 16, 20, 23, 28, 32, 34
better, 8, 11, 14
between, 2, 12
beyond, 3, 21
Black, 2, 30
Blink, 6
blinking, 8, 11, 14
blocks, 34
Board, 25, 27
board, 3, 24, 31
boasts, 2, 15
bolted, 32
Both, 2
both, 2-3, 8, 11-12, 14
Bottom, 10, 13, 16, 20, 23, 28
bottom, 10, 13, 16, 20, 23, 28, 32
bottomcation, 32
Box, 4, 6, 10, 13, 16, 20, 23, 28, 32-34
box, 1, 10, 13, 16, 18-20, 23, 25-26, 28, 31-32
Boxes, 10, 13, 16, 20, 23, 28
boxes, 32-33
bracket, 6
Branch, 17-27, 34
branch, 1-2, 8, 10-11, 13-14, 16-18, 20, 22-23, 25, 27-28
Breaker, 2-3, 8-9, 11-12, 14-15, 18-19, 22, 25-27, 31, 34
breaker, 2-6, 8-11, 13-14, 16, 18-20, 22-23, 25-28, 34
Breakers, 2, 9, 15, 17, 19, 21, 24, 26-27, 34
breakers, 1-5, 8-14, 16, 19-20, 23-24, 26-28, 34
broadest, 3, 17
Brownout, 3
brownout, 8, 11, 14
Index
Browser, 6, 9
browser, 7, 9
Building, 2, 30-31
building, 1, 3, 8, 12, 17, 27
buildings, 1-3, 15
Built, 6
built, 2, 7
Burndy, 33
Bus, 3, 8, 11, 14, 31, 33
bus, 8-9, 11, 14, 33
Buses, 9, 12, 15
buses, 8-9, 11, 14
Busses, 9
but, 3, 7
button, 2, 30
buttons, 3
by, 1-3, 5, 8, 11, 14-15, 24, 27, 32-33
bypass, 3
C
CA, 1-34
Cabinet, 3-4, 29, 32
cabinet, 4, 8, 11, 14, 29
Cabinets, 10, 13, 16, 20, 23, 28
Cable, 9, 12, 15, 33
cable, 2-4, 8, 11, 29, 31
cables, 1-2, 4
California, 6
call, 1-34
campus, 4
Can, 34
can, 1-5, 7-9, 11-12, 14-15, 17, 24, 27, 34
cannot, 20, 23
cans, 34
capabilities, 2, 7
capability, 3, 8, 11, 14, 24
Capable, 2
capable, 3, 7
carry, 1
Case, 34
cases, 1-2
CAT, 2
Cat, 32
Catalog, 10, 13, 16, 20, 23, 28-31
catalog, 10, 13, 16, 20, 23, 28-31
CatalogMain, 20
catchModification, 32
cation, 32-33
CCF, 29
CCS, 29
cells, 1
Central, 31
central, 3-4
Certifications, 11, 14, 17, 27
Certificationsholiday, 8
chain, 4
Change, 33
change, 2, 4
changed, 2-3, 24
changes, 1-3
charge, 31
Chassis, 3, 10, 13, 16, 18, 20-23, 25, 28
chassis, 18, 20, 22-23, 25
Choices, 1
choose, 4
Circuit, 1, 19, 26-27, 32, 34
circuit, 1-4, 6, 8-11, 13-14, 16, 18-20, 22-28, 31-32, 34
circuits, 4, 27-28
Ckt, 10, 13, 16
ckt, 10, 13, 16, 20, 23, 28
Clamps, 32
Class, 17, 20, 23, 28
Client, 9
Clock, 6
clock, 2-3, 6-8, 11, 14, 24, 27
clocks, 1-2, 15
close, 1
closest, 4
closet, 4
closing, 1
closures, 3
coating, 33
Coatings, 33
Code, 1, 17
code, 10, 13, 16, 20, 23, 28, 33
colors, 2
com, 1-34
combination, 15
Combinations, 18, 22, 25
combinations, 12
comes, 4, 7
Command, 1-34
commands, 7
Commercial, 1-34
commercial, 3
Common, 32
common, 2
communicate, 2-3, 7
communicates, 7
communication, 2, 7, 9
Index
communications, 1, 3, 8
compatibility, 3
Complete, 32
complete, 4
completely, 2, 7
complex, 2
complexity, 1
component, 2
Components, 7-8, 11, 14
components, 1-2, 8, 11, 14
Compression, 33-34
compression, 33
computer, 3-4, 8, 11, 31
Computers, 31
Concealed, 32
concern, 1
conditions, 1
Conductor, 9, 12, 15
Conduit, 32
conduit, 2
conduits, 32
Configuration, 24
configuration, 2, 7
Configurations, 9, 12
configurations, 2-3, 8, 11, 14, 24
configured, 3, 9
conjunction, 3
connect, 3, 7, 14
connected, 2-4, 12, 15
connecting, 7
connection, 2
connections, 3
connectivity, 7
connectors, 33
consecutive, 31
Considerations, 1-2
considerations, 34
consist, 2
consists, 1
Construction, 32
construction, 4
contact, 1-3, 8, 11, 14, 24, 27
Contactor, 1
contactor, 1-2, 27
contactors, 1-3
contacts, 3
contained, 12
Containing, 9
contains, 2
Contents, 1, 7-8, 11, 14, 17, 21, 24, 27
continued, 6, 30-31
Control, 1-34
control, 1-4, 7-9, 11, 14-15, 17, 27
Controllable, 19, 26
controllable, 1-3, 5, 8, 11-12, 14, 20, 23
Controlled, 28
controlled, 2, 8-9, 11-12, 14, 27
Controller, 2-8, 10-14, 16, 21, 23, 25, 29-30
controller, 1-4, 6-8, 11, 14, 18, 22, 24, 27, 31
Controllers, 3-4, 8, 11, 21, 29, 31
controllers, 1-3, 6-8, 11, 14
Controls, 3, 6
controls, 8
Conventional, 19, 26
coordinate, 7
coordinator, 7
Copper, 33-34
copper, 33-34
Corbin, 32
cord, 4
COS, 31
cost, 2-3
Cover, 28, 32
cover, 32
Covers, 32
creating, 14
Cu, 19, 26, 33-34
current, 1
Custom, 31
custom, 3
Customer, 9
customer, 2, 7
customers, 1, 4
Customizable, 12
customizable, 2, 7
cutting, 2
D
Data, 3, 5, 8-9, 11-12, 14-15, 31
data, 7
Day, 3
day, 3, 21, 31
Daylight, 6, 8, 11, 14
days, 3, 31
Deadfront, 28
December, 1-34
dedicated, 2
Deep, 10, 13, 16, 28
deep, 10, 13, 16, 18, 25, 28
Delivery, 1-34
Index
Density, 33
Depending, 1
depth, 20, 23
Description, 1, 7-8, 10-11, 13-14, 17, 21, 24, 27-34
description, 16, 20, 23
Design, 1
design, 1
Designed, 2, 15
designed, 1, 3-4, 7, 17, 24, 27
detailed, 34
Determine, 10, 13, 16, 28
determine, 10, 13, 16, 20, 23, 28
determined, 33
Device, 18, 20, 22-23, 25, 34
device, 2-3, 6-7, 10, 13, 16, 18, 22, 25, 27-28
Devices, 2, 7, 23, 25, 30
devices, 1-2, 5, 7, 18-19, 22, 25-27
DevicesMain, 18, 22
DevicesOptional, 34
DFM, 31
diagnose, 4
diagnostics, 2, 8, 11, 14
diagnosticsany, 3
diagram, 12
different, 3
differently, 3
difficult, 2
Digital, 2, 7, 30
digital, 2, 5, 7, 24
Dimensions, 10, 13, 16, 20, 23, 28, 32
dimensions, 33
dimmable, 2, 7
Dimming, 6
dimming, 6-7
directly, 1-2, 7-9, 11, 14
Directory, 32
Discharge, 27
Disconnect, 18, 22, 25
disconnect, 34
discrete, 7
Display, 15, 31
display, 2, 6, 8, 11, 14, 29
distributed, 1-3, 5, 7, 9
Distribution, 1-34
distribution, 1, 17, 27
DK, 10, 13, 16, 18, 20, 22-23, 25, 28
DLP, 31
does, 2, 7
done, 2, 7
Door, 32
door, 32
Doors, 32
doors, 32
downtime, 1-2
Drip, 32
Driven, 24
drives, 5
dry, 2-3, 8, 11, 14, 24, 27
DSN, 2
dual, 1
due, 2
during, 1, 4
dynamically, 7
E
Each, 2-3, 5, 7, 9, 24
each, 2-3, 7-9, 11, 14, 18, 22, 31-32
easily, 3, 24
easy, 2
Eaton, 1-3, 5, 7-8, 11-12, 14-15, 17, 21, 24, 33
eaton, 1-34
EC, 1, 3, 7-8, 11, 14, 17, 21-24, 27, 29
ECD, 29
ECP, 29
ED, 10, 13, 16, 18-20, 22-23, 25-26, 28, 34
EDB, 10, 13, 16, 18-20, 22-23, 25-26, 28
EDC, 18-20, 22-23, 25-26, 34
edge, 2
EDH, 10, 13, 16, 18-20, 22-23, 25-26, 28, 34
EDS, 10, 13, 16, 18-20, 22-23, 25-26, 28
effective, 3
EHD, 10, 13, 16, 18-20, 22-23, 25-26, 28, 34
Eight, 9, 24
eight, 3, 5, 8, 11-12, 14-15, 24
either, 20, 23
Electrical, 1, 17
electrical, 1, 4, 7
elephone, 5
eliminate, 1
eliminated, 2
Embedded, 7-8
embedded, 2, 8-9
Emissions, 17
employs, 1
enabled, 3
enclosing, 32
Enclosure, 32
enclosure, 10, 13, 16, 32
Enclosures, 17
End, 32
Index
Energy, 17
energy, 2-3, 6, 8, 11, 14, 17
Engineering, 4
engineers, 4
Engraved, 32
ENS, 31
ensure, 4
entire, 2
Entrance, 34
EntranceTo, 34
entry, 34
EP, 9, 12, 15
Equipment, 8, 11, 14, 17, 31, 34
equipment, 1, 3, 6, 8, 11, 14, 19, 24, 26-27
equipped, 7
ertically, 16
essential, 7
Ethernet, 6, 9, 31
even, 8
Event, 24
event, 2, 8, 11, 14
Every, 9
every, 2
Example, 13, 20, 23, 28
ExampleInstructions, 10, 16
Examples, 3
exceed, 28
exceeds, 10, 13, 16, 20, 23
existing, 1, 3-4, 7
expand, 3, 7
expander, 5
Expansion, 3, 9, 21, 23
expansion, 2, 5, 12, 14
expenses, 31
exposes, 32
extend, 3, 21, 34
Extended, 30
extended, 7
extension, 4, 12
extensive, 1
External, 6, 29
external, 3, 5-8, 11, 14, 24
EZ, 10, 13, 16, 20, 23, 28, 32
EZB, 10, 13, 16, 20, 23, 28
EZT, 10, 13, 16, 20, 23, 28
F
Fabricated, 32
facilities, 2-3, 15
facility, 2-3, 7
Factory, 4, 15
factory, 2-4, 21, 34
fails, 2
Failure, 2
failure, 2-3, 8, 11, 14
Family, 1
family, 1
fasteners, 32
fault, 19, 26-27
fax, 31
FB, 18, 20, 22-23, 25
FCC, 17
FCL, 18, 22, 25
FD, 10, 13, 16, 18-20, 22-23, 25-26, 28, 34
FDB, 18-20, 22-23, 25-26, 34
FDC, 10, 13, 16, 18-20, 22-23, 25-26, 28, 34
feature, 7
Features, 3, 8, 11, 14
features, 2, 7, 15
Federal, 17, 27
Feed, 34
feed, 1, 18, 22, 25
feedback, 2, 7-8, 11, 14
feet, 4, 29
Field, 4
field, 1, 3, 21, 24
finish, 10, 13, 16, 20, 23, 28
finished, 33
firmware, 6
first, 31
Fixed, 32
fixed, 3
Flash, 6
Flexibility, 1-2
flexibility, 1-2, 8
Floor, 9, 12, 15
flush, 29, 32
following, 10, 13, 16, 20, 23, 28
follows, 33
For, 1-34
for, 1-9, 11-12, 14-15, 17, 19-20, 23, 26-29, 31-34
form, 3
four, 1, 10, 12-13, 16-17, 20, 23-24, 27-28, 34
Frame, 10, 13, 16, 20, 23, 28, 32, 34
frame, 32
Index
free, 2
freeing, 1
frequency, 34
frequent, 3
From, 10, 13, 16, 20, 23, 28
from, 1-4, 7-8, 10-11, 13-14, 16, 20-21, 23-24, 27-28, 34
Fronts, 20, 23, 32
ft, 5
full, 3
fully, 2, 7, 18, 22, 25
function, 1
functionality, 3, 21
functions, 2, 4
further, 3
Fuse, 18, 22, 25
fuse, 20, 23
Fuses, 18, 22, 25
fusible, 20, 23
fusing, 1
G
galvanized, 10, 13, 16, 20, 23, 28, 33
gasketed, 32
gateway, 6-7
gauge, 10, 13, 16, 20, 23, 28, 33
GE, 32
geographic, 7
GFCI, 19, 26-27
GFP, 19, 26-27
GHB, 18-20, 22-23, 25-27, 34
GHBGFEP, 27
GHBHID, 27
GHBS, 18-20, 22-23, 25-26, 29
GHQ, 19, 26-27
GHQRSP, 8, 11, 14, 19-20, 23, 26-27
gives, 2, 7
graphics, 31
Gray, 34
gray, 10, 13, 16, 20, 23, 28, 34
Green, 1, 7-8, 11, 14, 17, 21, 24
Ground, 9, 12, 15, 33-34
ground, 33
Group, 4
group, 3-4, 24, 27
grouped, 3, 24, 28
grouping, 3, 24
groupings, 3, 24
groups, 1
Guide, 1, 5-8, 11, 14, 17, 21, 24, 27
guide, 31
gutter, 32
Gutters, 10, 13, 16, 20, 23, 28, 32
GuttersTamperproof, 32
GuttersTrims, 28
H
Handle, 34
handle, 32
hard, 2
Hardware, 3
hardware, 2, 8, 11, 14, 31
harvesting, 6
has, 2-3, 7, 14
have, 1-3, 7
heart, 3, 27
Height, 10, 13, 16, 20, 23, 28, 33-34
height, 10, 13, 16, 20, 23, 28
help, 4, 7
HFD, 10, 13, 16, 18-20, 22-23, 25-26, 28, 34
HGHB, 27
HID, 27
High, 27
high, 1-2, 15, 32
Hinges, 32
hinges, 32
HJD, 18, 20, 22-23, 25, 28
HKD, 10, 13, 16, 18, 20, 22-23, 25, 28
Holiday, 3, 8, 11, 14
holiday, 2, 11, 14-15
Holidays, 6
holidays, 6
Horizontally, 23
hours, 4
house, 4
houses, 3, 21
housing, 6
hrs, 6
Index
I
IBC, 17
ideal, 3-4, 17
IEEE, 7
If, 2
II, 28
illuminated, 2
Immediate, 1-34
immediately, 20, 23, 28
In, 1-2, 7
in, 1-4, 6-17, 19-21, 23, 26, 28, 32, 34
Inch, 10, 13, 16, 28, 33
inch, 10, 13, 16, 18-20, 23, 25-26, 28, 32-33
Inches, 10, 13, 16, 20, 23, 28
inches, 10, 13, 16, 20, 23, 28, 34
inchesertically, 28
include, 3
included, 3, 18, 22, 24-25, 31, 34
Includes, 10, 13, 16, 18, 22, 25, 28, 34
includes, 2, 8, 11, 14, 20, 23, 31, 33
including, 2
incoming, 34
incorporate, 2
incorporates, 1-2, 4
Increased, 32-33
increased, 2
indicators, 6
individual, 2-4, 8, 11, 14, 24, 27
individualized, 12
individually, 3, 5
Indoor, 34
indoor, 34
industrial, 2, 15
industry, 2-3, 7, 17
inexpensive, 1
information, 7, 10, 13, 16-17, 20, 23, 27-28
inhibiting, 33
Injector, 30
Input, 1, 3, 6, 8, 11, 14
input, 3, 5, 7
Inputs, 3, 5
inputs, 1-3, 5, 7-8, 11, 14-15, 24
install, 2
Installation, 2
installation, 2-3
installations, 1
installed, 1, 3, 8-9, 11, 14, 21, 32, 34
installing, 2
instead, 7
Instructions, 13, 20, 23, 28
Insulated, 33
Integral, 3, 18, 22, 25
integral, 18, 22, 25, 27
integrate, 8
Integrated, 7
integrated, 2-3, 7, 24
Integration, 5, 8, 11, 14
integration, 5, 8
integrations, 3
intelligence, 1-3, 7
Intelligent, 8, 11, 14
Intensity, 27
interaction, 2
Interface, 4, 6-7, 12, 30
interface, 2, 4, 31
interfaced, 1
interfaces, 9
Interior, 10, 13, 16, 28
interior, 1, 32
internal, 7
Internet, 1, 9, 12
Interposing, 3
interposing, 24
Interrupting, 18-19, 22, 25-27
interrupting, 10, 13, 16, 20, 23, 28
into, 1-4, 24, 27
IP, 2, 6, 9
is, 1-5, 7-11, 13-18, 20, 22-25, 27-28, 33-34
Isolated, 33
isolated, 33
It, 2-4, 7, 17, 27
it, 2, 4, 7
items, 29-31
its, 2, 7, 14
J
jack, 4
JCI, 3, 31
JD, 18, 20, 22-23, 25, 28
JDC, 18, 20, 22-23, 25, 28
Johnson, 3, 6
Index
K
kA, 18-19, 22, 25-27
kAIC, 10, 13, 16, 20, 23, 28
kcmil, 19, 26, 33-34
KD, 10, 13, 16, 18, 20, 22-23, 25, 28
KDC, 10, 13, 16, 18, 20, 22-23, 25, 28
Key, 32
key, 24, 31
keyed, 32
keying, 32
keypad, 2, 8, 11, 14
keyway, 32
Kit, 31
kits, 8, 11, 14
KMParts, 1-34
knockout, 10, 13, 16, 28
knockouts, 20, 23
L
Label, 34
label, 34
labeled, 34
Labor, 2
labor, 2
LAN, 1, 9, 12, 15
Laptop, 31
large, 3, 17
Layout, 8, 10-11, 13-14, 16-17, 20-21, 23, 27-28
layout, 3, 10, 13, 16, 20, 23, 28
LCD, 2, 6, 8, 11, 14-15, 29, 31
LCL, 18, 25
leading, 7
leads, 34
learning, 7
LED, 2, 6
left, 3, 9-10, 13, 16, 20, 23, 28, 32
length, 5
levels, 1, 4
lieu, 32
life, 2
Light, 34
light, 3, 10, 13, 16, 20, 23, 28, 34
Lighting, 1-34
lighting, 1-4, 7-8, 11, 14-15, 17, 27
Lights, 3
lights, 2, 8, 11, 14
limited, 1
line, 3, 7
link, 34
listed, 8, 11, 14, 18, 22, 25, 33
listing, 34
LL, 32
Load, 3
load, 1-3, 7-8, 11, 14-15, 20, 23
loads, 3-5, 7
Local, 3, 6, 15
local, 2, 4, 7
locally, 3, 24
located, 1, 4, 20, 23, 28
location, 2, 4, 7
lock, 32
Lockoff, 34
Locks, 32
locks, 32
log, 2-3, 15
logging, 3, 5, 7, 31
longer, 7
LonWorks, 6
LOS, 4
loss, 2-3, 8, 11, 14-15
lot, 34
Low, 2, 30
low, 2-3, 7
lower, 2
lowest, 18, 22, 25
LT, 10, 13, 16, 20, 23, 28, 32
LTC, 31
Lug, 10, 13, 16, 18, 20, 22-23, 25, 28
lug, 8, 10-11, 13-14, 16, 19, 26, 28, 34
Lugs, 33-34
lugs, 10, 13, 16, 20, 23, 28, 33-34
M
mA, 19, 26-27
made, 3, 24
magnetic, 2, 8, 11, 14
Main, 10, 13, 16, 18, 20, 22-23, 25, 28, 33-34
main, 8, 10-11, 13-14, 16, 18, 20, 22-23, 25, 28, 33-34
mains, 10, 13, 16, 20, 23, 28
Maintained, 30
major, 1-2
Index
make, 1, 33
makes, 1
Management, 17
management, 2-3, 6, 8, 11, 14
Mandatory, 5
mandatory, 5
Manual, 5
manually, 2
many, 2, 7
Master, 32
master, 12
Mastic, 32
Material, 34
Matrix, 24
matrix, 6, 8, 11, 14
Max, 34
max, 5
Maximum, 5-6, 10, 13, 16, 19, 26, 33
maximum, 2, 5, 12, 15, 19, 26-28
MaximumCircuit, 26
may, 1-4, 8, 11, 18, 20-23, 25, 27-28
Mechanical, 34
mechanical, 2, 33-34
medium, 3, 17
meet, 1-2, 7, 17, 27
meeting, 1, 34
Memory, 3, 8, 11, 14
memory, 2, 6-8, 11, 14-15
message, 2, 15
Messages, 8, 11, 14
Metal, 32
metal, 32
Metasys, 3, 31
method, 4
methods, 1-2
Micarta, 32
microprocessor, 1-2, 7-8, 11, 14-15, 17
microprocessortemporary, 2
minimal, 1
Minimum, 10, 13, 16, 28
minimum, 10, 13, 16, 20, 23, 28
mixed, 20, 23
MLO, 10, 13, 16, 18, 22, 25, 28
mm, 10, 13, 16, 18-20, 23, 25-26, 28, 32, 34
MOD, 3, 31
Modbus, 3, 6, 31
model, 1
Modem, 12
modem, 4, 31
Modes, 2
Modifi, 32-33
Modification, 32-34
modification, 2
Modifications, 8, 11, 14, 17, 21, 24, 27, 32
Module, 2, 7, 30
module, 5, 7
Molded, 34
Momentary, 30
momentary, 2
monitor, 3
monitoring, 4
more, 1, 3-4, 8
most, 1, 3
mount, 6, 29
Mounted, 10, 13, 16, 20, 23, 28
mounted, 1-4, 8, 10-11, 13-14, 16, 20, 23, 28
Mounting, 6
mounting, 1
mounts, 17
MPC, 31
much, 2
multi, 4
multiple, 24
multitude, 2
must, 18, 20, 22-23, 28, 34
N
Nameplate, 32
nameplate, 32
National, 1, 17, 32
Native, 31
native, 3, 8
nd, 9, 12, 15
NEC, 1, 6
necessary, 2
need, 2-3, 7-8, 11, 24
needed, 9, 20, 23
needs, 1-2, 7, 17, 27
NEMA, 32
Network, 2-4, 6, 9, 12, 30-31
network, 2-3, 6-8, 11
networkable, 2-3, 7
networked, 1-3, 8, 11, 17
networks, 8
Neutral, 20, 23, 33
neutral, 20, 23, 27, 34
new, 1-4, 7
next, 10, 13, 16, 20, 23, 28
NIB, 4, 6, 31
No, 5-6, 15, 24
Index
no, 2, 7, 31
Non, 6, 34
non, 4, 29-31
Not, 7, 19, 26
not, 1-2, 5, 18, 22, 25, 34
Note, 10, 13, 16, 20, 23, 28-30, 33-34
noted, 34
Notes, 5-6, 18-20, 22-23, 25-27, 31
notice, 6
notification, 7
notifications, 7
Number, 5, 10, 13, 16, 20, 23, 28-31, 34
number, 5-6, 10, 13, 16, 20, 23, 28
Numbers, 29-32
numbers, 29-32
O
occupancy, 2-3, 7
of, 1-8, 10-18, 20-25, 27-28, 31-32, 34
Off, 3-4
off, 1-4, 6-8, 11, 14, 27
offer, 1
offered, 2, 8, 11, 14
offers, 3, 7, 17, 27
office, 2-3, 15
Often, 2
often, 1-2
On, 3-4, 6
on, 1-4, 6-7, 9-10, 13, 16, 19-20, 23, 26-28, 32-34
onboard, 2, 7
One, 31
one, 2-4, 7-9, 11, 14, 32, 34
Online, 4
online, 4
Only, 4, 18, 22, 25, 33-34
only, 7, 10, 13, 16, 18-20, 22-23, 25-28, 34
OPC, 6
open, 32
opening, 1
operate, 2-3, 8, 11, 14
operated, 3, 24, 27
operation, 2
Operational, 2
operator, 31
optimal, 2
optimization, 8, 11, 14, 18, 22, 25, 31
Option, 6
option, 14
Optional, 3, 5, 31
optional, 2-3, 6, 21
OR, 23
or, 1-34
order, 20, 23, 34
ordered, 3, 21
other, 3, 7, 33-34
out, 34
output, 6-8, 11, 14
Outputs, 5-6
outputs, 2, 7
over, 1-3, 5, 7-8, 11, 32
overcurrent, 1
overload, 1
Override, 3-4, 8, 11, 14
override, 2, 4-6, 8, 11, 14-15, 24, 31
Overview, 1, 7-8, 11, 14, 17, 21, 24, 27
own, 14
oz, 34
P
package, 31
Padlockable, 34
PadlockableMain, 34
Page, 1, 7-8, 11, 14, 17-18, 21-22, 24, 27
page, 2
Paintadditional, 34
Painted, 33
painted, 10, 13, 16, 20, 23, 28
Painting, 33
pair, 3, 8, 11
Panel, 8-11, 13-14, 16-17, 20-21, 23, 27-28, 33
panel, 1, 9-10, 13-16, 20-21, 23, 27-28, 32, 34
Panelboard, 1, 3, 7-11, 13-14, 16-18, 21-22, 24-25, 27-28
panelboard, 1-4, 8, 10-11, 13-14, 16-18, 20-25, 27-28,
32-33
Panelboards, 1-34
panelboards, 1-4, 6, 8, 11-12, 14-15, 17, 34
PanelboardTechnical, 14
panels, 1, 3, 5, 9, 12, 14, 31-32, 34
Part, 17
passes, 7
Password, 6
password, 1
past, 1
PC, 9, 12, 31
Index
PCR, 31
peak, 4
Per, 33-34
per, 1, 4, 6-7, 21, 31-34
perform, 1-2
performance, 4
periods, 6
Peripherals, 31
Permanent, 32
permanently, 32
personal, 4, 8, 11
personnel, 19, 26-27
Phase, 34
phase, 1, 8, 10-11, 13-14, 16-17, 20, 23-24, 27-28
phosphatized, 33
photo, 1-2, 7
photocell, 27
photocells, 3
Piano, 32
pigtail, 4, 29
place, 32
placed, 9
plant, 4
plastic, 32
Plated, 33
plated, 33
platform, 7
play, 3
Plug, 3
plug, 4
plugged, 3
point, 32, 34
Pole, 20, 23
pole, 6, 10, 13, 16, 19-20, 23, 26-28, 34
Poles, 20, 23
poles, 20, 23, 28
port, 3, 6
possible, 3-4
Pow, 1-34
Power, 2-3, 5, 8, 11, 14, 17, 29-31
power, 1-4, 8, 11, 14, 21
powered, 3
PRC, 1-18, 20-25, 27-31, 34
PRCBCB, 31
PRCDS, 2, 30
PRCDSNPI, 30
PRCDSNSP, 30
PRCEP, 1, 3, 8, 11-12, 14
PRCJCI, 3
PRCLCD, 31
PRCLS, 2, 30
PRCPS, 31
PRCSMARTCABLE, 31
PRCWIOM, 2, 7, 30
PRCWS, 2, 7, 30
PRCWSI, 7, 30
pre, 4
premier, 2, 15
prewired, 2
price, 33-34
Prices, 33
printer, 31
prior, 32
priorities, 3
priority, 3
PRL, 9, 29, 33
Product, 1, 5, 7-8, 11, 14, 17-18, 21-22, 24-25, 27
products, 7
professional, 4
program, 3-4, 6
programmable, 2, 8, 11, 14, 17
programmed, 2-3, 7, 9
Programming, 4, 15, 25
programming, 2-4, 7-8, 11, 14, 24, 31
programs, 4
prompted, 4
proof, 32
protected, 1, 6
Protection, 1
protection, 1-3, 8, 11, 14-15, 19, 26-27
Protocol, 8
protocol, 2-3, 5, 8
provide, 1, 8, 11, 14, 32, 34
provided, 2
provides, 2-4, 24, 27
Provision, 27
pullout, 20, 23
purchased, 8
purchaser, 32
pushbutton, 3, 24
Q
QBCAF, 19, 26-27
QBGF, 19, 26-27
QBGFEP, 19, 26-27
Qualified, 17
quarter, 32
quickly, 7
Index
R
RAC, 4
radio, 7
rail, 5
Rails, 5
Range, 30, 33-34
range, 3, 17
rate, 6
Rated, 18, 22, 25, 33
rated, 1, 17-19, 22, 25-27
Rating, 18-19, 22, 25-27, 33-34
rating, 1, 10, 13, 16, 18, 20, 22-23, 25, 28, 33
RatingAmpere, 18, 22
Ratings, 33
ratings, 1-3
rd, 9, 12, 15
re, 1
Real, 3
real, 2, 8, 11, 14
recommended, 4
recovery, 3, 8, 11, 14
reduction, 3
Refer, 17, 21, 24, 27
refer, 33
regular, 12
relay, 1-3, 5, 7, 24, 27
relays, 1-2
reliability, 2, 7
Remote, 4-5, 9, 12, 19, 26
remote, 1, 3-4, 9, 12, 34
remotely, 3-4, 7, 24
replace, 34
replacement, 27
replaces, 3
require, 1-3, 34
Required, 15, 20, 23, 31
required, 1, 3-5, 7, 10, 13, 16, 25, 28, 31-32
requirement, 34
requirements, 1, 3, 34
Requires, 18, 25
requires, 1-3, 27, 34
requiring, 4
response, 1
restore, 3
retailers, 3
Retrofit, 1, 31
retrofit, 2, 4, 8, 11, 14
Retrofitting, 1
reused, 4
rewiring, 1-3, 24
right, 3, 9, 20, 23, 32
rise, 2, 15
riser, 12
rivets, 32
robust, 2, 7-8
room, 7
rooms, 1
rosette, 32
RS, 6-7, 12
RTU, 6
rules, 3
Running, 7
rust, 33
S
same, 1, 3-4, 17-18, 20, 22-23, 25, 28, 31
SBG, 31
SC, 4
SCC, 3
SCG, 31
schedule, 3, 6
scheduled, 3-4
schedules, 2, 6, 8, 11, 14
Scheduling, 6
scheduling, 2-3, 7-8, 11, 14-15
schedulingBACnet, 8
scheme, 2-3
schemes, 2, 27
schools, 3
screens, 31
Screws, 32
screws, 32
seamless, 2
Section, 10, 13, 16, 20, 23, 28
section, 13, 16, 32
See, 17, 20, 23
see, 7, 18, 22, 34
segment, 7
Seismic, 17
Select, 10, 13, 16, 20-21, 23, 28
Selection, 1, 5-8, 10-11, 13-14, 16-18, 21-22, 24-25, 27
selection, 2
self, 3
sensor, 7
sensors, 2-3, 7
serial, 4, 31
Index
Series, 18, 22, 25
series, 18, 22, 25
Server, 6
server, 2, 6-8, 31
Service, 4, 24, 34
services, 4
set, 4, 7
Setup, 4
setup, 4
sheet, 32-33
shield, 32
shielded, 3, 8, 11
shipment, 32
Shor, 1
short, 1, 18, 22, 25
shot, 2, 8, 11, 14
Should, 3
shown, 10, 12-13, 16, 18, 20, 22-23, 25, 28, 34
Shunt, 34
shunt, 34
Side, 10, 13, 16, 20, 23, 28, 32
side, 9, 28
sides, 3
signal, 1
Silver, 33
silver, 33
similar, 24
Simple, 24
simple, 1-3, 24
Simplicity, 2
simplifying, 1
Simply, 4
Single, 19, 26-27, 34
single, 1-2, 8, 10-11, 13-17, 20, 23-24, 28
site, 2
six, 1-2, 31
size, 10, 13, 16, 19-20, 23, 26, 28
sizes, 1
sizing, 3
SLAN, 5
slave, 3
SLO, 31
Small, 30
small, 3, 17, 27
Smart, 2, 15, 18, 20, 22-23, 25, 31
smart, 20, 23
SOAP, 6
SOC, 3, 8, 11, 14, 31
Software, 4, 8, 11-12, 31
software, 2-4, 7-8, 11, 14, 18, 22, 24-25, 31
Solenoid, 27
solenoid, 3
solid, 32
Solution, 1, 7-8, 11, 14, 17, 21, 24
solution, 3, 27
solutions, 12
some, 1, 3
sophisticated, 1
SOR, 20
Space, 1, 29
space, 1, 20, 23, 27, 34
Spaces, 20, 23
spaces, 3, 10, 13, 20, 23, 28
spaceson, 16
SPB, 31
Special, 32-33
special, 3, 24
Specific, 3-4, 8, 11, 21, 23, 31
specific, 3
Specification, 17, 27
Specifications, 8-9, 11-12, 14-15
specified, 34
Specify, 20, 23
specifying, 1
split, 12
Splitter, 30
Spray, 34
spray, 34
Square, 33
square, 33
stadiums, 3
Stainless, 34
Standalone, 15
standalone, 2-3, 8, 11, 14-15, 17, 27
Standard, 3, 9-10, 13, 16, 20, 23, 28, 32-34
standard, 1-3, 7-9, 11-12, 14, 21, 29-34
Standards, 6, 8, 11, 14, 17, 27
Start, 15
start, 25, 31
Startup, 2, 4-5, 31
startup, 1-2, 5, 18, 22
state, 2, 7
station, 31
status, 2, 6-8, 11, 14
Steel, 34
steel, 10, 13, 16, 20, 23, 28, 33
stored, 2, 7
stores, 4
straightforward, 2
strategy, 2, 7
style, 34
Sub, 9, 12, 15, 34
Subject, 17
subjected, 1
subnetwork, 14
Such, 8, 11, 14
Index
such, 3-4, 34
Sumter, 4
Supply, 29
supply, 2, 4-5, 31
Support, 1-34
support, 3-4, 8, 11-12, 14, 18, 22, 25
Supports, 28
Supportswitched, 4
Supportthe, 4
surface, 10, 13, 16, 20, 23, 28-29
SUT, 31
Switch, 2-3, 5, 7-8, 11, 14, 30-31
switch, 2-3, 5, 7-8, 11, 14-15, 24, 27
switched, 2-3, 24, 27
Switches, 2
switches, 1-3, 7
Switching, 8, 11, 14, 27
switching, 2-3, 6-8, 11, 14, 21
SWS, 31
Symmetrical, 18-19, 22, 25-27
symmetrical, 10, 13, 16, 20, 23, 28
System, 2-4, 8-9, 11-12, 14-15, 21, 25, 29
system, 1-4, 7-9, 11, 14-15, 17-18, 22, 27, 31
systems, 1, 3-4, 17, 27
T
table, 10, 13, 16, 20, 23, 28, 34
Tabulation, 23, 28
TabulationHorizontally, 20
tailored, 2
Taking, 33
Tamperproof, 32
task, 4
tasks, 2
TCP, 6
team, 4
Tech, 1-34
Technical, 4, 8-9, 11-12, 15, 31
technicians, 4
technology, 2, 7
Tee, 32
Telephone, 4, 8, 11, 14, 31
telephone, 4
temperature, 33
tenant, 3
tenants, 2, 8, 11, 14
Terminal, 33-34
terminal, 31, 33-34
Terminals, 34
terminals, 34
terminated, 1, 4
Terminations, 33
test, 33
TEU, 32
th, 9, 12, 15
than, 3-4, 33
that, 1-4, 7-8, 11, 14-15, 18, 21-22, 24-25, 27
The, 1-4, 7-9, 11, 14-15, 17-18, 21-22, 24-25, 27, 34
the, 1-5, 7-18, 20-25, 27-28, 31, 34
theatres, 3
them, 1-2
There, 2-3
there, 2-3
thermal, 2, 8, 11, 14
These, 1
these, 1, 34
They, 1-2
This, 2-3, 7, 27
this, 3-4, 7, 12
those, 1, 4
Three, 6, 29
three, 1-2, 4, 8, 10-11, 13-14, 16-17, 19-20, 23-24,
26-28, 34
Through, 34
through, 2, 7-8, 11, 14
throughout, 2, 9
Thru, 9, 12
Time, 3, 6, 8, 11, 14
time, 1-3, 6-8, 11, 14-15, 21, 24, 27
Tin, 33
tin, 33
Title, 6
To, 3, 7-8, 11, 14, 32, 34
to, 1-4, 7-9, 11-12, 14-15, 17-18, 20-25, 27, 29-34
TOC, 4, 8, 11, 14, 31
Today, 1
together, 28, 32
tone, 4
Top, 10, 13, 16, 18, 20, 22-23, 25, 28
top, 20, 23, 32
Total, 5, 10, 13, 16, 20, 23, 28
total, 2, 5, 10, 13, 15-16, 20, 23, 28
touch, 4
Touchup, 34
Traditional, 1
traditional, 1-2, 17
trained, 4
Training, 4
training, 31
transfers, 7
Index
Trim, 10, 13, 16, 20, 23, 28, 32
trim, 32
Trims, 10, 13, 16
trims, 32-33
Trip, 33-34
trip, 31, 34
tripping, 34
trips, 34
trouble, 2
troubleshoot, 4
turn, 1, 32
twisted, 3, 8, 11
Two, 19, 26
two, 3-4, 7-8, 11, 14, 19, 21, 24, 26-27, 32
Type, 18-19, 22, 25-27, 32-34
types, 33
Typeype, 32
Typical, 9
typically, 1
U
UBC, 17
UG, 31
UL, 6, 8, 11, 14, 17, 27, 33-34
under, 34
unique, 9
unit, 7-8, 31
Units, 20, 23, 28, 33
units, 3, 10, 13, 16, 20, 23, 28
Universal, 3-5, 21, 25
universal, 2, 31
until, 2
unwanted, 1
Up, 8, 11, 15, 29
up, 1-4, 7-8, 11-12, 14-15, 21, 24-25, 31
upgrade, 8
upon, 18, 22, 25
upstream, 1, 18, 22, 25
USC, 3, 31
use, 10, 13, 16, 19-20, 23, 26, 28
Used, 17, 27
used, 2-3, 7-8, 11, 14-15
user, 14, 31
users, 4
using, 2-4, 6-7, 9, 20, 23-24
utilized, 2
utilizes, 2, 8, 11, 14
utilizing, 5
V
Vac, 1, 3, 10, 13, 16-17, 19-20, 23-24, 26-28, 34
valuable, 1, 7
various, 3-4, 8, 11, 14
varying, 1
Vdc, 7
version, 1
versions, 3
Vertically, 10, 13, 20, 23
very, 2
via, 6, 9, 15
voice, 4
volatile, 6
Volt, 26, 31
Voltage, 2, 30, 34
voltage, 2, 7
voltages, 8, 11, 14
Volume, 1-34
VPN, 9
W
wall, 1, 3-4, 27
warning, 2-3, 8, 11, 14
way, 3, 7
Web, 2, 6-9, 31
web, 1
webserver, 9
week, 3
well, 2, 7
WEM, 32
were, 1
When, 9-10, 12-13, 16, 20, 23, 28
when, 4-5, 32
where, 4
which, 1-3, 7, 32
White, 2, 30
who, 4
Wide, 10, 13, 16, 28
wide, 10, 13, 16, 19, 26, 28, 32
widely, 8
Index
Width, 10, 13, 16
width, 1, 20, 23
will, 3-4, 10, 13, 16, 21
Windows, 4
Wire, 33-34
wire, 1-2, 5, 10, 13, 16-17, 20, 23-24, 27-28
Wireless, 2, 7, 30
wireless, 1-2, 7
wirelessly, 7
wires, 7
Wiring, 34
wiring, 1, 17, 24
With, 2, 7, 29
with, 1-14, 16, 18, 20-25, 28, 31-34
within, 1-2, 4, 6, 8, 11-12, 15, 28
without, 3, 8, 10-11, 13, 16, 20, 23-24, 28
work, 3
Workstation, 9
would, 7
WPRC, 30
www, 1-34
WX, 30
X
Xckt, 20
XML, 6
Y
Yale, 32
year, 7
Yes, 5-6
YesCSA, 6
YesEthernet, 6
YesProtocols, 6
YesTime, 6
you, 7
your, 2, 7, 15
yrs, 6
YS, 10, 13, 16, 20, 23, 28
Z
Zone, 24
zone, 2-3, 7, 24, 28, 30
Zones, 24, 28
zones, 1, 3, 5-6, 24, 27
Zoning, 27
Download