OWNER’S MANUAL
I. RECEIPT & SUPPORT INSTALLATION:
You should carefully inspect your Kairak unit for damage
during delivery. If damage is detected, you should save all
the crating materials and make note on the carrier’s Bill
Of Lading describing this. A freight claim should be filed
immediately.
After uncrating the unit, select a level location for final
placement. Install the legs or casters as shown below.
Compacts Supports (“Stem” type legs & casters)
Compact Undercounter & Prep-Table
KUH Series/KUL Series/KUP Series/KUS Series
Compact Cabinets (electromechanical)
The temperature is set at the factory but local conditions may
necessitate slight adjustment. The temperature control is
located in the front of the evaporator housing. To adjust, turn
the adjustment screw with a screw driver a small amount at a
time; turning counterclockwise lowers the temperature. An
“OFF” position is fully counterclockwise and interrupts power
to the compressor and condenser fan only, not the entire
refrigerator.
II. Defrost Cycles:
All Compacts, defrost cycles will occur every 6 hours.
III. GENERAL CARE:
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEAN
ING ANY PARTS OF THE UNIT.
Louvers must be free of any obstruction which could
prevent proper air-flow.
All Kairak equipment should be cleaned only with warm water, mild soap
and a soft cloth. Apply with a dampened cloth and wipe in the direction of
the metal grain.
Most units are supplied with a cord and plug,
which can simply be plugged into a dedicated
appropriately sized outlet. For those requiring
hard-wiring directly to the power supply, this should
be done by only a qualified electrician.
Avoid the use of strong detergents and gritty, abrasive cleaners as they
may tend to mar and scratch the surface. Do not use cleansers containing
chlorine, this may promote metal corrosion.
Compact Cabinets
Are fully operational and no action is required to start.
Please note, most compacts are equipped with a
electromechanical control.
P/N 375-60293-00 (rev. 03-13)
Care should also be taken to avoid splashing the unit with water, containing
chlorinated cleansers, when mopping the floor around the unit.
For stubborn odor spills, use baking soda and water (mixed to a 1 TBSP
baking soda to 1 pint water ratio).
IV. ADJUSTING THE SHELVES:
Shelves and shelf clips are shipped with the unit. For each shelf, insert four
(4) shelf clips into the pilaster slots at the same height. The shelf clips have a
small projection on top which holds the shelf in position and prevents it from
slipping forward. After installing shelf clips on pilasters, place shelves on clips.
V. CLEANING THE CONDENSER :
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS OF THE UNIT.
Remove rear bottom perforated access panel.
Vacuum or brush any dirt, lint or dust from the finned condenser coil, around the compressor and other cooling system parts as indicated.
If significant dirt is clogging the condenser fins, use compressed air to blow this clear.
VI. TROUBLE SHOOTING:
PROBLEM
1. Condensing unit fails to start.
2. Condensing unit operates for prolonged
periods or continuously.
VII. CONTACT/WARRANTY INFORMATION:
POSSIBLE SOLUTION
NOTE: Before making contact, please make sure you have model
and serial number of unit available. Amp plate with information needed
is located on the unit.
a. Check if cord & plug has been disconnected.
a. Are door(s) or drawer(s) closing properly?
c. Evaporator coils iced. Needs to defrost.
3. Food Compartment is too warm.
a. Check door(s) or drawer(s) and gasket(s) for proper seal.
b. Check if a large quantity of warm food was recently added or the
door was kept open for a long period of time.
c. Microprocessor control setting is too high, readjust.
4. Food Compartment is too cold.
a. Check if a large quantity of very cold or frozen food has recently
been added. Allow adequate time for the cabinet to recover its
normal operating temperature.
b. Adjust the microprocessor control to warmer setting, readjust.
5. Condensation on exterior surface.
a. Check door(s) or drawer(s) alignment & gaskets for proper seal.
b. Condensation on the exterior surface of the unit is perfectly
normal during periods of high humidity.
c. Check perimeter heat setting and increase setting if <100.
6. Compressor hums & does not start.
a. Call for service.
Amp Plate
NOTE: You will be required to register for a login name and pass code
to access our on-line information/registration.
WARRANTY AND SERVICE:
Kairak’s warranty coverage warrants that Kairak-branded products are free of defects in materials and factory workmanship. Kairak’s warranty is extended only to the original
purchaser and shall not apply to any failures resulting from damage in transit, improper installation, alteration, normal wear, misuse, abuse, improper voltage, accident or
negligence. The warranty excludes; T-stat adjustments, time clock adjustments, gaskets, cutting boards, filters, clogged drains, ice build-up with no mechanical failures, and the
loss of contamination of food due to mechanical or electrical failure. Warranty does not apply outside the UnitedStates.
In order to be covered under this warranty, prior authorization to perform the necessary and appropriate service must be obtained from the factory. Model and Serial number must
be provided at the time of service request. Kairak does not assume responsibility for any expenses, including labor, parts or travel expenses incurred without such prior
authorization. Kairak not be liable, whether in contract or in tort or under any other legal theory for loss of use, revenue or profit, substitute use or performance, incidental, indirect
or special and/or consequential damages, loss of refrigerant or for any other loss or cost ofsimilar type. Such related charges will be back charged to the responsible party. The
decision of the Kairak Service and Warranty, as to whether a defect is within the terms of this warranty shall be final.
Failure to object or provision contained in a customer’s purchase order or other communication shall not be deemed as a waiver of terms or conditions of their warranty, nor shall it
be considered acceptance of such provisions. This warranty supersedes and is in lieu of all other warranties, expressed or implied and of other obligations of liabilities, on the part
of Kairak. In case of freight damage, do not refuse shipment, but call agent’s attention to its condition, making careful note of the details on freight bill before freight charges are
paid. File claim for damages with freight agent immediately.
BLU fixtures manufactured by Kairak hold a 3-year parts and labor warranty. Kairak holds a 5-year compressor warranty, with a one-time compressor only replacement after the
first year. Kairak will warranty the labor to replace the compressor for the first three years, 30 days from the ship date. After the first three years, labor, tax, shipping and
miscellaneous parts will not be included. Please contact our warranty department for compressor replacement procedures during the warranty period. BLU remote Fixtures are
designed to operate with Kairak remote systems only. Violation of these terms will void all warranty. Refrigerant fixtures manufactured by Kairak hold a 1-year parts and labor
warranty. Kairak holds a 5-year compressor warranty, with a one-time compressor only replacement after the first year. Kairak will warranty the labor to replace thecompressor
for the first year, 30 days from the ship date. After the first year, labor, tax, shipping and miscellaneous parts will not be included. Please contact our warranty department for
compressor replacement procedures during the warranty period.
Remote systems manufactured by Kairak hold a 1-year parts and 90-day labor warranty on the remote system, with an option to purchase 1-year labor warranty at the time of
purchase order receipt. This warranty does not apply to motors, switches, controls,accessories or parts manufactured by others and purchased by Kairak, unless the manufacturer
warranties the same to Kairak.
Kairak holds a 5-year compressor warranty, with a one-time compressor only replacement after the first year. Kairak will warranty the labor to replace the compressor for the first
year, 30 days from the ship date. After the first year, labor, tax, shipping and miscellaneous parts will not be included. Please contact our warranty department for compressor
replacement procedures during the warranty period.
To request authorized service, call the Kairak Service and Warranty Hotline: (800) 833-1106.
After-hour requests must be urgent in nature and documented with Kairak’s after-hours service line prior to service being performed. Kairak is responsible for straight time only,
unless otherwise approved by the warranty department.
HOURS OF OPERATION:
Monday thru Friday 7:30 am - 4:00 pm PST
Kairak
1158 N. Gilbert St, Anaheim, CA 92801
Phone (714) 870-8661 Fax (866) 210-7542