Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J, 140G-K, 140MG-K, 140G-M, 140MG-M, 140G-N, 140MG-N (Cat 1494V-M70; 1494V-M71; 1494V-M72) WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. Installation, adjustments, putting into service, use, assembly, disassembly, and maintenance shall be carried out by suitably trained personnel in accordance with applicable code of practice. In case of malfunction or damage, no attempts at repair should be made. The product should be returned to the manufacturer for repair. Do not dismantle the product. Table of Contents Page Enclosure with Handle Cutout 1 - Locate Circuit Breaker Mechanism 2 - Handle Installation 3 - Cut Connecting Rod 4a - 140G-G, 140MG-G, 140G-I, 140MG-I Circuit Breaker Installation 4b - 140G-H, 140MG-H, 140G-J, 140MG-J Circuit Breaker Installation 4c - 140G-K, 140MG-K Circuit Breaker Installation 4d - 140G-M, 140MG-M Circuit Breaker Installation 4e - 140G-N, 140MG-N Circuit Breaker Installation 5 - Connecting Rod and Mechanism Adjustment Procedure 2 2 3 3 4 6 7 8 11 Enclosure without Handle Cutout 6- Locating and Installing Door Catch 7- Locating and Drilling Handle Holes 8- Circuit Breaker Testing 12 13 14 Accessory List 15 Variable Depth, Flange Operated Circuit Breaker Mechanisms 2 Enclosure with Handle Cutout 1 Locate Circuit Breaker Mechanism BB CC1 AA EE AA BB CC1 CC2 DD EE Wire Bending Space 140G-G / 140MG-G 140G-H / 140MG-H 140G-I / 140MG-I 140G-J / 140MG-J 5/16" 1 - 41/64" 3" 3 - 1/2" 7 - 1/2" 6” 140G-K / 140MG-K 29/64” 1 - 47/64” 4" 4 - 1/2" 9 - 5/16" 12” 140G-M / 140MG-M 4 - 1/2" 4 - 1/32" 5" 5" 13 - 1/2" 12” 140G-N / 140MG-N 4 - 1/2" 4 - 1/32" 5" 5" 13 - 1/2" 12” Frame Size DD CC2 2 Handle Installation 1 2 Install gasket. Install handle and spring bracket. 3 Install defeater lever. 1494F-M1, -P1 or -S1 30-40 lb-in 7-11 lb-in 1494F-M2 or -S2 60-80 lb-in 7-11 lb-in IMPORTANT: Apply grease to O-Ring to retain into handle groove. Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms Enclosure with Handle Cutout (Cont’d) 3 Cut Connecting Rod 1 2 N Enclosure Working Depth (Flange to Mounting Plate) 3 Rod Cut Connecting Rod Catalog Number Circuit Breaker Mechanism Circuit Breaker Frame 1494V-M70 140G-G / 140MG-G 140G-I / 140MG-I 140G-H / 140MG-H 140G-J / 140MG-J 1494V-RA4 1494V-RB4 Rod Cut N - 3-1/2" N - 4" 1494V-M71 140G-K / 140MG-K N - 4-1/2" 1494V-M72 140G-M / 140MG-M 140G-N / 140MG-N N - 3-3/4” Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) 3 Variable Depth, Flange Operated Circuit Breaker Mechanisms 4 Circuit Breaker Installation 4a 140G-G; 140MG-G; 140G-I; 140MG-I 1 Verify that the disconnect handle and toggle on the circuit breaker are in the “OFF” position. 2 Rotate connecting rod into drive bar (10) full turns of engagement. 3 4 Install circuit breaker operating mechanism into panel. Choose proper insulation barrier as labeled. Bend side panels of insulation barrier inward. 140G-I 140G-J 140G-G 140G-H R 140G-G 140G-I 140G-H 140G-J 23 - 37 lb-in Remove liner from two-sided tape. 6 Align holes on insulation barrier with holes on operating mechanism. 7 Press firmly in place. 9 Attach toggle adjustment plate. TAPE 5 L L 23 - 37 lb-in 8 Install circuit breaker onto insulation barrier and mechanism. 10 lb-in Go to Page 11 to assemble connecting rod and springs to handle Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms 5 Circuit Breaker Installation (Cont'd) 4b 140G-H; 140MG-H; 140G-J; 140MG-J Reposition bail mechanism Installation Removal 1 8 2 4 7 L L 3 L 5 L 6 10 Verify that the disconnect handle and toggle on the circuit breaker are in the “OFF” position. 11 Install circuit breaker operating mechanism into panel. 12 Rotate connecting rod into drive bar (10) full turns of engagement. 140G-I 140G-J 140G-G 140G-H 140G-G 140G-I R R 9 140G-H 140G-J 23 - 37 lb-in Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Choose proper insulation barrier as labeled. Bend side panels of insulation barrier inward. 6 Variable Depth, Flange Operated Circuit Breaker Mechanisms Circuit Breaker Installation (Cont'd) 4b 140G-H; 140MG-H; 140G-J; 140MG-J Cont'd Remove liner from two-sided tape. 14 Align holes on insulation barrier with holes on operating mechanism. 17 Attach toggle adjustment plate TAPE 13 L L L L 23 - 37 lb-in 15 Press firmly in place. 16 Install circuit breaker onto insulation barrier and mechanism. 10 lb-in Go to Page 11 to assemble connecting rod and springs to handle Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms Circuit Breaker Installation (Cont'd) 4c 140G-K; 140MG-K Verify that the disconnect handle and toggle on the circuit breaker are in the “OFF” position. 2 Rotate connecting rod into drive bar (10) full turns of engagement. 3 Install circuit breaker operating mechanism into panel. R R 1 40 - 60 lb-in Install insulation barrier (provided with circuit breaker). 4 Remove liner from two-sided tape. 5 Align holes on insulation barrier with holes on operating mechanism. Attach toggle adjustment plate TAPE 8 L L L L 23 - 37 lb-in 17 lb-in 6 Press firmly in place. 7 Install circuit breaker onto insulation barrier and mechanism. Go to Page 11 to assemble connecting rod and springs to handle Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) 7 Variable Depth, Flange Operated Circuit Breaker Mechanisms Circuit Breaker Installation (Cont'd) 4d 140G-M; 140MG-M 1 Verify that the disconnect handle and toggle on the circuit breaker are in the “OFF” position. 2 Rotate connecting rod into drive bar (10) full turns of engagement. 3 Install circuit breaker operating mechanism into panel. 90 - 130 lb-in Install insulation barrier (provided with circuit breaker). 4 Remove liner from two-sided tape. 5 Align holes on insulation barrier with holes on operating mechanism. 8 Attach toggle adjustment plate TAPE 8 40 - 60 lb-in 6 Press firmly in place. 7 Install circuit breaker onto insulation barrier and mechanism. 17 lb-in Go to Page 11 to assemble connecting rod and springs to handle Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms 9 Circuit Breaker Installation (Cont'd) 4e 140G-N; 140MG-N Reposition bail mechanism 4 40 - 60 lb-in 1 40 - 60 lb-in 5 6 23 - 37 lb-in 2 3 7 Verify that the disconnect handle and toggle on the circuit breaker are in the “OFF” position. Publication 1494V-IN105E-EN-P - September 2014 8 Rotate connecting rod into drive bar (10) full turns of engagement PN-242292 DIR 10000787413 (Version 04) 10 Variable Depth, Flange Operated Circuit Breaker Mechanisms Circuit Breaker Installation (Cont'd) 4e 140G-N; 140MG-N Install insulation barrier (provided with lugs). Cont'd 9 Install circuit breaker operating mechanism into panel. 10 Remove liner from two-sided tape. 11 Align holes on insulation barrier with holes on operating mechanism. 12 Press firmly in place. 13 Install circuit breaker onto insulation barrier and mechanism. TAPE 90 - 130 lb-in L 14 Attach toggle adjustment plate. 22 lb-in 40 - 60 lb-in Go to Page 11 to assemble connecting rod and springs to handle Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms Connecting Rod and Spring Assembly to Handle 5 Hitch Pin Connecting Rod 2 2 1 1 L L Primary Link 3 L L 4 Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) 11 Variable Depth, Flange Operated Circuit Breaker Mechanisms 12 Enclosure without Handle Cutout 6 Locating and Installing Door Catch · Provided with projections for welding. · Projections can also be used as a guide for drilling holes. · Can be used as a template to drill corresponding holes in the enclosure door. · User to supply the hardware for fastening the bracket. · Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. · The bracket hardware must be inaccessible to unauthorized personnel. · Dimension K (3/4" to 1") · When using large disconnect handle kit only (1494F-M2 or -S2), use door catch provided with handle kit. · When using large disconnect handle kit and small door hardware kits (1494V-L1, -LL1, -L2 or -LL2), use door catch provided with door hardware kit. · Dimension K (1-1/8" to 1-3/8") · When using large disconnect handle kit only (1494F-M2 or -S2), use door catch (40492-080-02) which can be ordered from factory. · When using large disconnect handle kit and large door hardware kits (1494V-L3 or -LL3), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top 22 - 37 lb-in Door Catch TOP VIEW Flange Thickness Enclosure Door K Door Catch Mounting Bracket C Enclosure Base Door Catch D Publication 1494V-IN105E-EN-P - September 2014 B PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms 13 Enclosure without Handle Cutout · Enclosures with a Flange Thickness less than 3/16" use dimensions below to install disconnect handle. · Enclosures with a Flange Thickness 3/16" and greater use dimensions in Alternate Mounting Kit 1494V-H6 to install disconnect handle. 7 Locating and Drilling Handle Holes C C B B A A (2) .328 Dia. Holes G E E (2) .265 Dia. Holes Square corners or up to 1/4" radius H G Door Catch Mounting Bracket F J D Door Catch Mounting Bracket 1/2" D 1/4" H To make slot drill (3) 1/2" diameter holes and remove burrs Figure 1 FRAME HANDLE 140G-G, H 140MG-G, H 140G-I, J 140MG-I, J 140G-K 140MG-K 140G-M 140MG-M 140G-N 140MG-N 1494F-M1 (Figure 1) 1494F-M1 (Figure 1) 1494F-M1 (Figure 1) 1494F-M2 (Figure 2) 1494F-M2 (Figure 2) F H Figure 2 A (MIN) B (MIN) C (MAX) D E F G H J 3-1/2” 29/32” 1-3/32” 1-5/8” 2-11/32” 4-11/16” 1-9/16” 1” 7/8” 10-29-32” 29/32” 1-3/32” 1-5/8” 2-11/32” 4-11/16” 1-9/16” 1” 7/8” 13-3/32” 29/32” 1-3/32” 1-5/8” 2-11/32” 4-11/16” 1-9/16” 1” 7/8” 17-5/16” 1-3/8” 1-3/32” 2” 3-23/32” 6-1/2” 5/16” 5-1/2” NA 21-7/8” 1-3/8” 1-3/32” 2” 3-23/32” 6-1/2” 5/16” 5-1/2” NA Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) 14 8 Variable Depth, Flange Operated Circuit Breaker Mechanisms Testing of Circuit Breaker Connecting Rod Hitch Pin Spring Handle Link L L Defeator Lever Toggle Adjustment Plate 140G / MG-G, H, I, J 140G / MG-K 140G / MG-M 140G / MG-N 23 - 37 lb-in 40 - 60 lb-in “ON” Position 1. Move defeater lever down and move handle to the ON position. 2. If the circuit breaker does not turn “ON”, loosen (2) screws on toggle adjustment plate. 3. Move toggle adjustment plate toward line terminals. 4. Tighten the (2) toggle adjustment plate screws to torque value in table above. 5. If the circuit breaker still can not be turned “ON”, return handle to the OFF position. 6. Unhook spring, remove hitch pin and separate connecting rod from handle link. 7. Turn connecting rod one full turn clockwise. 8. Reattach connecting rod and handle link, hitch pin and spring. 9. If the circuit breaker still can not be turned “ON”, repeat Steps 6, 7 and 8 if necessary. “OFF” Position 1. 2. 3. 4. 5. Move handle to the “OFF” position. If the cirucit breaker does not turn “OFF”, unhook spring, remove hitch pin and separate connecting rod from handle link. Turn connecting rod one full turn clockwise. Reattach connecting rod and handle link, hitch pin and spring and then retest. If the circuit breaker still can not be turned “OFF”, repeat steps 2, 3 & 4. “RESET” Position 1. 2. 3. 4. 5. 6. Manually trip the circuit breaker while in the “ON” position. Move handle to the “OFF” position to reset. If circuit breaker does not reset, unhook spring, remove hitch pin and separate connecting rod from handle link. Adjust connecting rod by turning it clockwise 1-2 turns and then retest. Repeat steps 1-4 until circuit breaker resets. Verify that the circuit breaker can be turned “ON”, “OFF” and “RESET” following the steps above. NOTE: Twisting of the bail mechanism is acceptable when the handle is in the full “ON” or full “OFF” position. Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Variable Depth, Flange Operated Circuit Breaker Mechanisms Components Cat No. Description Circuit Breaker 1494F-M1 1494F-P1 1494F-S1 5-1/2" Painted Metal Handle 5-1/2" Molded Handle 5-1/2" Stainless Steel Handle 140G-G, 140MG-G 140G-H, 140MG-G 140G-I, 140MG-I 140G-J, 140MG-J 140G-K, 140MG-K 1494F-M2 1494F-S2 7-1/2" Painted Metal Handle 7-1/2" Stainless Steel Handle 140G-M, 140MG-M 140G-N, 140MG-N 1494V-RA4 Connecting Rod Enclosure Working Depth: 6-3/4" to 23" 140G-G, 140MG-G 140G-H, 140MG-G 140G-I, 140MG-I 140G-J, 140MG-J 140G-K, 140MG-K 1494V-RB4 Standard Connecting Rod Enclosure Working Depth: 6-3/4" to 23" 140G-M, 140MG-M 140G-N, 140MG-N 1494V-M70 Circuit breaker mechanism 140G-G, 140MG-G 140G-H, 140MG-G 140G-I, 140MG-I 140G-J, 140MG-J 1494V-M71 Circuit breaker mechanism 140G-K, 140MG-K 1494V-M72 Circuit breaker mechanism 140G-M, 140MG-M 140G-N, 140MG-N 1495-N85 (1) N.O. Auxiliary Contact 1495-N86 (1) N.C. Auxiliary Contact 1495-N87 140G-G, 140MG-G 140G-H, 140MG-G 140G-I, 140MG-I 140G-J, 140MG-J Insulation Kit Publication 1494V-IN105E-EN-P - September 2014 140G-G, 140MG-G 140G-H, 140MG-G 140G-I, 140MG-I 140G-J, 140MG-J 140G-K, 140MG-K 140G-M, 140MG-M 140G-N, 140MG-N PN-242292 DIR 10000787413 (Version 04) 15 Bulletins: 507, 513, 513H, 523E, 523F, 523G, 1233, 1233X, 1233V NEMA Starter Size Horsepower Rating For Combination Starter 0 1 2 3 4 5 1/10..1/3 HP 1/10…1 HP 1/10…1 HP 1/2…1 HP 1-1/2…3 HP 1-1/2…3 HP 1-1/2…3 HP 5 HP 5 HP 1/10…1/3 HP 1/10…1 HP 1/10…1 HP 1/2…1 HP 1-1/2…3 HP 1-1/2…3 HP 1-1/2…3 HP 5 HP @ 200V 5…7-1/2 HP 5…7-1/2 HP 5…7-1/2 HP 5…7-1/2 HP 10 HP 10 HP 10 HP 15 HP 15 HP 15 HP 20…25 HP 20…25 HP 15…25 HP 30 HP 30 HP 30…50 HP 40…50 HP 30 HP 40…50 HP 60 HP 60…75 HP 100 HP 75…100 HP 50 HP 60 HP 75 HP 60…75 HP 100 HP 125 HP 125…150 HP 200 HP 150…200 HP Voltage 200V - 230V 460V 575V 200V - 230V 460V 575V 200V - 230V 460V 575V 200V - 230V 460V 575V 200V - 230V 460V 575V 200V - 230V 200V 460V 575V 230V 200V 460V 575V 200V - 230V 460V 575V 230V 460V 575V 200V - 230V 575V 230V 460V 575V 200V 200V - 230V 575V 460V 575V 200V 230V 575V 460V 575V Circuit Breaker Rating Circuit Breaker Cat No. 15A 140MG-G8P-C15 30A 140MG-G8P-C30 15A 140MG-G8P-C15 30A 50A 140MG-G8P-C30 140MG-G8P-C50 30A 140MG-G8P-C30 50A 140MG-G8P-C50 30A 140MG-G8P-C30 100A 140MG-G8P-D10 50A 140MG-G8P-C50 100A 50A 150A 140MG-G8P-D10 140MG-G8P-C50 140MG-J8P-D15 100A 140MG-G8P-D10 150A 200A 100A 150A 200A 150A 250A 300A 400A 300A 400A 200A 300A 400A 300A 140MG-J8P-D15 140MG-J8P-D20 140MG-G8P-D10 140MG-J8P-D15 140MG-J8P-D20 140MG-J8P-D15 140MG-J8P-D25 140MG-K8P-D30 140MG-K8P-D40 140MG-K8P-D30 140MG-K8P-D40 140MG-J8P-D20 140MG-K8P-D30 140MG-K8P-D40 140MG-K8P-D30 Note: Contact Rockwell Automation for circuit breaker use in bulletin 503 and 503L. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1494V-IN105E-EN-P - September 2014 PN-242292 DIR 10000787413 (Version 04) Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.