General Service Bulletin Circuit Breaker Verification and Replacement Product Code: 0514 (YHC/YSC), 0516 (WSC), and 0518 (THC/TSC) ATTENTION: Warnings, Cautions, and Notices appear at appropriate sections throughout this literature. Read these carefully: WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTIONs Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. It could also be used to alert against unsafe practices. NOTICE: Indicates a situation that could result in equipment or property-damage only accidents. SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and airconditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2014 RT-SVB114A-EN WARNING Proper Field Wiring and Grounding Required! All field wiring MUST be performed by qualified personnel. Improperly installed and grounded field wiring poses FIRE and ELECTROCUTION hazards. To avoid these hazards, you MUST follow requirements for field wiring installation and grounding as described in NEC and your local/state electrical codes. Failure to follow code could result in death or serious injury. WARNING Personal Protective Equipment (PPE) Required! Installing/servicing this unit could result in exposure to electrical, mechanical and chemical hazards. • • • Before installing/servicing this unit, technicians MUST put on all PPE required for the work being undertaken (Examples; cut resistant gloves/sleeves, butyl gloves, safety glasses, hard hat/bump cap, fall protection, electrical PPE and arc flash clothing). ALWAYS refer to appropriate Material Safety Data Sheets (MSDS)/Safety Data Sheets (SDS) and OSHA guidelines for proper PPE. When working with or around hazardous chemicals, ALWAYS refer to the appropriate MSDS/SDS and OSHA/GHS (Global Harmonized System of Classification and Labelling of Chemicals) guidelines for information on allowable personal exposure levels, proper respiratory protection and handling instructions. If there is a risk of energized electrical contact, arc, or flash, technicians MUST put on all PPE in accordance with OSHA, NFPA 70E, or other country-specific requirements for arc flash protection, PRIOR to servicing the unit. NEVER PERFORM ANY SWITCHING, DISCONNECTING, OR VOLTAGE TESTING WITHOUT PROPER ELECTRICAL PPE AND ARC FLASH CLOTHING. ENSURE ELECTRICAL METERS AND EQUIPMENT ARE PROPERLY RATED FOR INTENDED VOLTAGE. Failure to follow instructions could result in death or serious injury. Introduction The purpose of this general service bulletin is to advise the field of a problem associated with circuit breakers and disconnect switches applied to certain Precedent™ packaged air conditioning units (see “Affected Units,” p. 2). These devices may not function as designed after repeated use. 2 The action described in this service bulletin IS being taken to address a safety concern. This is a MANDATORY RETROFIT. Discussion Schneider Electric®, makers of the Square D® brand, notified Trane that a limited production run of circuit breakers and disconnect switches may not function as designed. After repeated use, wear on an internal component may cause these circuit breakers to remain energized in an overcurrent condition. Similarly, disconnect switches can remain energized in the off position. Affected Units Affected units may include Precedent packaged units, models THC, TSC, WSC, YHC, or YSC, with model number digit 19 as 1 or 2, manufactured between 08 May 2013 and 27 Aug 2013, serial number range 1139*****L through 1335*****L, product code 0514, 0516, and 0518. The units may have a Schneider Electric (Square D) circuit breaker or disconnect switch catalog number FA, FH, FI, or FY (1-, 2-, and 3-pole, 15–100 amp) with date codes 13193 through 13241 (inclusive). Note: Not all units will have a defective circuit breaker or disconnect switch. Corrective Action WARNING Hazardous Voltage w/Capacitors! Disconnect all electric power, including remote disconnects and discharge all motor start/run capacitors before servicing. Follow proper lockout/ tagout procedures to ensure the power cannot be inadvertently energized.Verify with an appropriate voltmeter that all capacitors have discharged. Failure to disconnect power and discharge capacitors before servicing could result in death or serious injury. 1. Gain access to the unit-mounted circuit breaker or unitmounted disconnect switch by removing the front cover of the Through The Base Electric section. 2. Determine the circuit breaker or disconnect switch catalog number and date code. Note: The catalog number and date code are located on the front of the circuit breaker as shown in Figure 1, p. 3. 3. If the breaker or switch is catalog number FA, FH, FI, or FY and the date code is 13193 through 13241 (inclusive), replace the device. RT-SVB114A-EN Figure 1. Check for affected catalog numbers (FA, FH, FI, or FY) and date codes (13193 through 13241, inclusive) Catalog # Date Code Catalog # Catalog # Date Code Date Code 1-Pole Breaker 2-Pole Breaker 3-Pole Breaker Parts Ordering Information Obtain the required parts from your local Trane Parts Center. These may include the part numbers in Table 8. Table 1. Affected part numbers Part # Part # BKR00840 BKR00846 BKR00841 BKR00847 BKR00842 BKR00848 BKR00843 SWT01682 BKR00844 SWT01829 BKR00845 Material Disposition Return the defective circuit breaker or disconnect switch to the Trane Parts Center for credit. Questions Contact Light Commercial Technical Support with questions regarding this general service bulletin. To contact them, send a message to techsupportlightprecedent@trane.com. RT-SVB114A-EN 3 Precedent, Trane and the Trane logo are trademarks or registered trademarks of Trane in the United States and other countries. All trademarks referenced in this document are the trademarks of their respective owners. Schneider Electric and Square D are trademarks or registered trademarks of Schneider Electric. The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2014 Trane All rights reserved RT-SVB114A-EN 12 Mar 2014 We are committed to using environmentally New conscious print practices that reduce waste.