P516-275 18-HD39D1-4 Thermostat Installation Instructions Models TZEMT400AB32MAA TZEMT500AB32MAA Use this guide and the “Thermostat Starter Kit Quick Start Guide” for installation. The information contained in document P516-000, “Thermostat Model TZEMT043AZ32MAA”, does not apply to this kit. The TZEMT400 and TZEMT500 Thermostats are compatible with single and multistage forced air systems, including: • Gas furnace systems • Oil furnace systems • Electric furnace systems • Heat pump systems • Air conditioning systems The TZEMT400 and TZEMT500 Thermostats may be compatible with some other system types, including: • Boiler systems • Geothermal systems • Multi-zoned systems The TZEMT400 and TZEMT500 Thermostats are not compatible with the following system types: • Radiant floor systems Schlage LiNK™ Customer Service: (877) 288-7707 • Wall heating systems • Proprietary HVAC Communication Protocols ÎÎ The TZEMT400 and TZEMT500 Thermostats are not compatible with dual fuel systems (gas or oil furnace & heat pump combined) without adding a dual fuel accessory relay kit. These thermostats do not have an emergency heat relay when applied with a dual fuel relay kit. ÎÎ NOTE: A 24 Volt common and hot wire MUST be connected to the TZEMT400 or TZEMT500 for operation. Contents Physical Installation and Wiring........................................................................................................................................2 Field Wiring Diagrams - TZEMT500..................................................................................................................................6 Field Wiring Diagrams - TZEMT400..................................................................................................................................9 Optional Remote Temperature Sensors Installation - TZEMT500 Only..........................................................................10 System Settings at Thermostat.......................................................................................................................................12 Perform System Checkout..............................................................................................................................................14 Enroll Thermostat into Schlage LiNK™ System..............................................................................................................15 Product Specifications....................................................................................................................................................16 Operation........................................................................................................................................................................17 Menu Maps.....................................................................................................................................................................19 User Settings..................................................................................................................................................................20 Installer Settings.............................................................................................................................................................25 Schedules.......................................................................................................................................................................28 LED Reference................................................................................................................................................................30 Warranty..........................................................................................................................................................................31 Physical Installation and Wiring 1 WARNING Voltage hazard. Can cause electrical shock or equipment damage. Disconnect power to heating and cooling equipment before beginning installation. 2 Remove the existing thermostat cover from the wall plate. Leave wires attached. The look of the existing thermostat may vary Consult instructions that came with existing thermostat as needed. MERCURY NOTICE When this control is replacing an old control that contains mercury in a sealed tube, do not dispose of your old control in the trash. Dispose of properly. Contact your local waste management authority for instructions regarding recycling and proper disposal of the old control. A listing of heating, ventilating and air conditioning wholesalers that participate in the Thermostat Recycling Corporation’s recycling program are available at www.thermostat-recyle.org. 3 Thermostat cover Wall plate Identify the existing HVAC System Type from the list below. Indoor Unit Type Gas Furnace System Type Single Stage Gas Furnace 1 Stage Cooling Multi Stage Gas Furnace 1 Stage Cooling 2 Stage Cooling Electric Furnace or Air Handler Single Stage PSC Blower, Electric Furnace or Air Handler 1 Stage Cooling 1 Stage Heat Pump Multi Stage, Variable Speed Blower, Electric Furnace or Air Handler 1 Stage Cooling 1 Stage Heat Pump 2 Stage Cooling 2 Stage Heat Pump CAUTION: EQUIPMENT DAMAGE HAZARD - Improper system type selection can lead to equipment damage or high utility costs. Use the System Type list to properly select and setup the control to ensure proper heating and cooling system operation. 4 Determine if your system has a 24 VAC common wire which is required to power the thermostat. a. If your existing thermostat has a terminal labeled C, X, B, or COM with a wire connected to it, skip to step 6. b. If your thermostat does not have a C, X, B, or COM terminal, or does not have a wire connected to it, go to step 5. 2 5 Connect a 24 VAC common wire to power the thermostat. a. Locate all unused wires from the thermostat wire bundle and write down the colors. • 24V Common wire is typically (not always) colored blue d. Locate the thermostat wire bundle inside the air handler or furnace panel. • This wire bundle is routed from the thermostat, through the walls, and into the air handler or furnace panel. • This bundle can be identified at the air handler or furnace by checking the wire colors connected and not connected and comparing to the wire bundle at the thermostat. Thermostat wire bundle G Unused wires W R b. Go to the indoor air handler or furnace and remove the cover(s) to access the 24 VAC air handler or furnace wire terminals. 24 VAC Air handler or Furnace wire terminals Air handler or Furnace cover c. W 24 VAC common terminal (C, X, B, or COM) R C Thermostat wire bundle C e. Find a wire from the thermostat bundle that is unused at the thermostat and at the air handler or furnace. • It is possible that one of the unused wires at the thermostat will already be connected to the 24 VAC common terminal at the air handler or furnace. If so, go to step 6. Find the 24 VAC common terminal identified with the letter C, X, B, or COM. • This terminal may already have a wire connected to it but it may not be a wire that is connected to the thermostat G Unused wires G W R C f. Unused wire Connect the unused wire to the 24 VAC terminal, then replace the air handler or furnace cover. • The 24 VAC common wire is typically (but not always) blue in color. If the blue wire is not used, it is recommended that you use the blue wire. G W R C Connect wire 3 6 Review the wiring chart information. a. Refer to: • Chart 1 - If you do NOT have a heat pump • Chart 2 - If you have a heat pump b. Select the correct row based upon the thermostat being replaced, and then circle the wire labels you have. c. Connect your wires as shown in the New Thermostat Terminals row. Chart 1: Gas or Electric (Single Stage or Multistage) Some wire terminals may not be used Themostat Being Replaced Wire Labels All Brands C R X RC RH W W2 W1 G Y F Y1 G Y1 Y2 B Connects to New Thermostat Terminals Chart 2: Heat Pump (Single Stage or Multistage) 24COM 24RC 24RH W1 Y2 Some wire terminals may not be used Themostat Being Replaced Trane/American Standard (Weathertron) or York W2/O/B Wire Labels COM R C RC RH E W X2 W1 B O G Y Y2 Y1 W2 Y AUX Other Brands COM R C RC RH E W O G Y X2 W1 B F Y1 X Y2 W2 Y AUX Lennox C R X RC RH E W O G Y X2 W1 **R F Y1 W2/O/B G Y1 **VR W2 **V Y Y2 AUX Connects to New Thermostat Terminals 24COM 24RC 24RH *W1 Y2 * Connect two wires to the W1 terminal **If your existing thermostat has a “V” or “VR” wire label, connect that wire to “24RC” on the new thermostat, then connect the wire labeled “R” to “W2/O/B” on the new thermostat 4 7 Remove existing wall plate. ÎÎ Note: During this process, make sure that the wires do not pull back into wall opening. a. Detach all wires from wall plate. b. Remove all screws attaching the wall plate to the wall and remove wall plate. ÎÎ See Mercury Notice on page 2. Wall plate 8 Separate the face of the new thermostat from the wall plate. Tabs Apply pressure at two tabs on top of wall plate to release it. ÎÎ NOTE: It is not recommended that this Z-wave thermostat be mounted onto metal structures. Metal may adversely affect the radio frequency (RF) communication between the thermostat and the Z-waveTM bridge. TM 24 C 24 RC 24 RH W1 G Y1 RS 1 RS 1 RS 2 RS 2 W2/ 0/B Y2 Wall plate 9 Mark two mounting holes using new wall plate. a. b. c. d. e. Pull wires through hole in center of wall plate. Locate the new wall plate over existing opening. Mark two holes with pencil. Use a level to verify that the two hole locations are level. Correct hole locations as needed. 24 C 24 RC 24 RH W1 G Y1 RS 1 RS 1 RS 2 RS 2 W2 /0/B Y2 10 Prepare two mounting holes. a. Drill 1/16” pilot holes in the two locations that were marked in step 9. If mounting to drywall with no studs behind it, enlarge pilot holes to 1/8” for anchors (included with the thermostat). b. If using anchors, screw them into the holes. Anchors 5 11 Install new wall plate. a. Pull wires through hole in center of wall plate. b. Locate the new wall plate over existing opening. c. Attach wall plate to wall using two screws provided. Do not overtighten. 24 C 24 RC 24 RH W1 G Y1 RS 1 RS 1 RS 2 RS 2 W2 /0/B Y2 12 Attach all wires securely to the new thermostat. (See the Field Wiring Diagrams on the following page.) Note: A wire must be connected to “24COM” to power the thermostat. a. Use the information from step 6 to match the wires to the correct terminals. b. Use 1/8” blade screwdriver to secure wires in terminals. 24 C 24 RC 24 RH W1 W2 /0 G CAUTION: EQUIPMENT DAMAGE HAZARD Improper wiring can lead to equipment damage. Follow the Terminal Connection information from step 6 carefully to ensure the control is wired properly. After wires are secure, bare wires MUST NOT touch each other. See the Field Connection Wiring Diagrams on the following pages for specific system applications. Y1 Y2 Field Wiring Diagrams - TZEMT500 The following table can be used to find the correct field connection wiring diagram for the HVAC System Type that is being installed. Indoor Unit 6 Outdoor Unit 1 Stage Cooling 2 Stage Cooling 2 Step Cooling 1 Stage Heat Pump 2 Stage Heat Pump 2 Step Heat Pump 1 or 2 Stage Gas Furnace (PSC/CTM) A NA NA NA NA NA 2 Stage VSPD Gas Furnace A A B NA NA NA COM Furnace A A A NA NA NA Air Handler (PSC/CTM) A NA NA C NA NA VSPD Air Handler A A B C C D COM Air Handler A A A C C C Oil Furnace (PSC) E NA NA NA NA NA VSPD Oil Furnace E E F NA NA NA System Type A - 1 or 2 Stage Heating with 1 or 2 Stage Cooling (Note 6) Thermostat Connection Gas Furnace or Air Handler Outdoor Unit 24VAC Common B 24VAC Common B/C 24VAC Return R 24VAC Return R (Note 5) JP1: internal RC/RH Jumper BLUE 24C RED WHITE Heat Stage 1 W1 Heat Stage 2 W2 Compressor Stage 1 Y1 Compressor Stage 1 Y1 Compressor Stage 2 Y2 Compressor Stage 2 Y2 RS2 Remote Sensor 2 RS2 W2/O/B Y1 COMP Wiring is not polarized Y2 COMP E G AN R N O W O BR BK RS1 G FAN YELLOW Remote Sensor 1 RS1 W1 HEAT GREEN (Note 2) (Note 3, Note 4) (Note 7) 24RH (Note 1) Fan G Remote Sensors 24RC Note 1 - May be W or W1 Note 2 - May be Y, Y1, or YLO Note 3 - May be Y or Y2 Note 4 - Y2 only found on variable speed furnace or air handler Note 5 - R required for 2 stage cooling unit Note 6 - For 2 Stage Cooling, outdoor unit contains two compressors Note 7 - The remote sensor feature is available only on the TZEMT500 Remote Temperature Sensor Connections and Operation: (Note 7) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reports the outdoor temperature to comfort control. Furnace (Note 2) System Type B - 2 Stage Variable Speed Gas Furnace or Variable Speed Air Handler with 2 Step Cooling (Note 3, Note 4) Thermostat Connection Outdoor Unit Gas Furnace or Air Handler 24VAC Common B 24VAC Common B/C 24VAC Return R 24VAC Return R JP1: internal RC/RH Jumper BLUE 24RC WHITE RS1 W1 HEAT GREEN Fan G RS2 G FAN YELLOW YLO Remote Sensor 1 RS1 24RH Heat Stage 2 W2 Compressor Stage 2 Y2 Remote Sensors (Note 5) 24C RED Heat Stage 1 W1 Compressor Stage 1 Y1 Jumper Remote Sensor 2 RS2 W2/O/B Y1 COMP Wiring is not polarized Y2 COMP Compressor Stage 1 Y O R AN G E BROWN Compressor Stage 2 BK O (Note 1) (Note 2) Note 1 - Field installed jumper from R to O. Note 2 - Cut/remove R to BK jumper Note 3 - For non-communicating variable speed air handler. (For communicating air handler, use system type A diagram.) Note 4 - For 2 Step Cooling, outdoor unit contains one 2 stage scroll compressor Note 5 - The remote sensor feature is available only on the TZEMT500 Air Handler (Note 2) Remote Temperature Sensor Connections and Operation: (Note 5) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reports the outdoor temperature to comfort control. Jumper System Type C - PSC, Variable Speed, or Communicating Air Handler with 1 or 2 Stage/Step Heat Pump (Note 4, Note 5, Note 6, Note 7) Thermostat Connection Air Handler Outdoor Unit JP1: internal RC/RH Jumper 24VAC Common B 24VAC Common B/C 24VAC Return R 24VAC Return R X2 Heat Stage 1 W1 BLUE RED WHITE (Note 1) O O Fan G Compressor Stage 1 Y1 Compressor Stage 1 Y1 Compressor Stage 2 Y2 Compressor Stage 2 Y2 24RH YELLOW G FAN Y1 COMP Remote Sensors (Note 8) Remote Sensor 1 RS1 RS1 RS2 Remote Sensor 2 RS2 W2/O/B Y2 COMP Wiring is not polarized E NG RA O N W O BR BK 24RC W1 HEAT GREEN (Note 2) (Note 3) 24C Note 1 - May be W or W1 Note 2 - May be Y, Y1, or YLO Note 3 - May be Y or Y2 Note 4 - Applies to 2 step heat pumps matched with communicating air handler only. All other variable speed air handlers use system type D diagram. Note 5 - For 2 Stage Cooling, outdoor unit contains two compressors Note 6 - For 2 Step Cooling, outdoor unit contains one 2 stage scroll compressor Note 7 - PSC air handler for single stage heat pump only Note 8 - The remote sensor feature is available only on the TZEMT500 Remote Temperature Sensor Connections and Operation: (Note 8) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reports the outdoor temperature to comfort control. 7 System Type D - Variable Speed Air Handler with 2 Step Heat Pump Air Handler Note 3 (Note 2) Thermostat Connection Air Handler Outdoor Unit JP1: internal RC/RH Jumper 24VAC Common B 24VAC Common B/C 24VAC Return R 24VAC Return R X2 Heat Stage 1 W1 BLUE WHITE Compressor Stage 1 Y1 RS2 G FAN YELLOW YLO Remote Sensor 1 RS1 W1 HEAT GREEN Jumper RS1 24RH O Fan G Compressor Stage 2 Y2 24RC (Note 1) O Remote Sensors (Note 4) 24C RED Y1 COMP W2/O/B Y2 COMP Compressor Stage 1 Y Remote Sensor 2 RS2 Wiring is not polarized E NG RA WN O O BR Compressor Stage 2 BK (Note 2) Note 1 - Field installed jumper from R to O Note 2 - Remove R to BK jumper Note 3 - For 2 Step Heat Pump, outdoor unit contains one 2 stage scroll compressor Note 4 - The remote sensor feature is available only on the TZEMT500 Remote Temperature Sensor Connections and Operation: (Note 4) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reports the outdoor temperature to comfort control. R1 (Isolation relay, See R1 below) System Type E - Oil Furnace with 1 or 2 Stage Cooling (Note 7) Outdoor Unit 24VAC Common B 24VAC Return R (Note 4) Thermostat Connection Oil FurnacePSC or Variable speed JP1: internal RC/RH Jumper BLUE 24VAC Common B/C 24VAC Return R O Compressor Stage 1 Y1 Compressor Stage 2 Y2 Compressor Stage 2 Y2 Note 1 - May be Y, Y1, or YLO Note 2 - May be Y or Y2 Note 3 - For variable speed oil furnaces, factory installed jumpers R to O and R to BK Note 4 - R to ODU required for 2 stage cooling models Note 5 - Variable speed furnace required for 2 stage cooling Note 6 - Field supplied Isolation Relay Note 7 - For 2 Stage Cooling, outdoor unit contains two compressors Note 8 - The remote sensor feature is available only on the TZEMT500 RS2 G FAN YELLOW W2/O/B Y2 COMP BR BK OW Remote Sensor 2 RS2 Y1 COMP (Note 1) (Note 2, Note 5) RS1 W1 HEAT GREEN Remote Sensor 1 RS1 24RH (Note 3) Fan G Compressor Stage 1 Y1 24RC WHITE Heat Stage 1 W1 Remote Sensors (Note 8) 24C RED Wiring is not polarized N OIL BURNER PRIMARY R1 (Note 6) Remote Temperature Sensor Connections and Operation: (Note 8) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reports the outdoor temperature to comfort control. R1 (Isolation relay, See R1 below) System Type F - Variable Speed Oil Furnace with 2 Step Cooling (Note 6) Outdoor Unit 24VAC Common B 24VAC Common C 24VAC Return R 24VAC Return R (Note 4) RED WHITE Heat Stage 1 W1 (Note 3, Note 4 ) GREEN Fan G Compressor Stage 1 Y1 YLO Compressor Stage 2 Y2 Compressor Stage 1 Y JP1: internal RC/RH Jumper BLUE O YELLOW (Note 1) 24RC 24RH W1 HEAT G FAN Y1 COMP Remote Sensors (Note 7) Remote Sensor 1 RS1 RS1 RS2 Remote Sensor 2 RS2 W2/O/B Wiring is not polarized BR OW N (Note 2) Note 1 - May be Y, Y1, or YLO Note 2 - May be Y or Y2 Note 3 - Factory installed jumpers R to O and R to BK Note 4 - Cut / remove R to BK jumper for 2 step cooling Note 5 - Field supplied Isolation Relay Note 6 - For 2 Step Cooling, outdoor unit contains one 2 stage scroll compressor Note 7 - The remote sensor feature is available only on the TZEMT500 24C Y2 COMP Compressor Stage 2 BK 8 Thermostat Connection Oil Furnace- Variable speed OIL BURNER PRIMARY R1 (Note 5) Remote Temperature Sensor Connections and Operation: (Note 7) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. Indoor sensor connected to RS1 and outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reports the outdoor temperature to comfort control. Field Wiring Diagrams - TZEMT400 IMPORTANT: Use the TZEMT500 field wiring diagrams as a guide when making field wiring connections to the TZEMT400. ÎÎ NOTE: The TZEMT500 terminal block configuration differs from the TZEMT400 terminal block. The TZEMT500 has two terminal blocks with 12 terminals and the TZEMT400 has one terminal block with 8 terminals. See the table below for a comparison of the terminal names. Functionality is the same for the matching terminals. Terminal Labels TZEMT500 TZEMT400 24C C 24V 24RC RC 24V 24RH RH 24V W1 W1 G G Y1 Y1 RS1 n/a RS1 n/a RS2 n/a RS2 n/a W2/O/B W2/O/B Y2 Y2 24C 24RC 24RH W1 G Y1 RS1 RS1 RS2 RS2 W2/O/B Y2 TZEMT500 wall plate C 24V RC 24V RH 24V W1 W2/O/B G Y1 Y2 Run Wires Here No wires in shaded areas TZEMT400 wall plate 9 Optional Remote Temperature Sensors Installation - TZEMT500 Only Wire specification (RS1 & RS2): 2 conductors, 18 gauge wire. Make sure that the sensor wires have a cable separate from the thermostat cable. Best results for distances of 100 feet or less. Accuracy may be affected for distances up to a maximum of 200 feet. Shielded cable is recommended for distances over 100 feet and less than 200 feet. CAUTION: Keep this wiring at least one foot away from large inductive loads such as electronic air cleaners, motors, line starters, lightning ballasts, and large distribution panels. Failure to follow these wiring practices may introduce electrical interference (noise) which can cause erratic system operation. Shielded cable is required if the above wiring guidelines cannot be met. Be sure to ground only one end of the shield to the thermostat common terminal. Tape back the other end of the shield. Remote Sensors Part Numbers Remote Indoor Sensor: Use ZZSENSAL0400AA for indoor applications. Remote Outdoor Sensor: Use BAYSEN01ATEMPA for outdoor applications. ÎÎ IMPORTANT: Make sure that the sensor wires have a cable separate from the thermostat cable. ÎÎ IMPORTANT: Follow directions below for averaging. These instructions replace the averaging information found in the Installer’s Guide for the ZZSENSAL0400AA. ÎÎ Note: Remote Sensor 2 can be selected as an indoor sensor or an outdoor sensor. Remote Temperature Sensor Connections and Operation: A) Indoor sensor connected to RS1. Replaces internal sensor. RS2 not connected. Remote Sensor 1 (RS1) replaces the internal temperature sensor of the thermostat. This allows the thermostat to be installed in a location different than the area where the temperature will be measured. Use ZZSENSAL0400AA. See Figure A. Figure A Remote Temp Sensor Black RS1 Red Sensor wiring is not polarized. B) Indoor sensor connected to RS2. Averages temperature with internal sensor. RS1 not connected. RS2 is used as an indoor temperature sensor that averages temperatures with the internal sensor. Use ZZSENSAL0400AA. See Figure B. If RS2 is set to indoor location (“IN” - Default selection in the thermostat installation set up menu) and a sensor is attached to the RS2 sensor terminals of the thermostat, the RS2 temperature is averaged with the thermostats internal temperature sensor. C) Indoor sensors connected to RS1 and RS2. Averages RS1 and RS2 sensor temperatures. Internal sensor is not used. Remote Sensor 1 (RS1) and Remote Sensor 2 (RS2) are both used as indoor sensors. The RS1 temperature and RS2 temperature is averaged. See Figure C. D) Outdoor sensor connected to RS2. Reports outdoor temperature to comfort control. RS2 is used as an outdoor temperature sensor. Use BAYSEN01ATEMPA. See Figure B. RS1 RS1 Sensor RS2 RS2 RS1 Figure B RS2 Remote Temp Sensor RS1 Black RS2 Red Sensor wiring is not polarized. RS2 Sensor RS2 Figure C Remote Temp Sensor Black RS1 Red RS1 Black RS2 Remote Temp Sensor RS2 Red RS2 RS1 Sensor RS2 Sensor Sensor wiring is not polarized. If RS2 is set to outdoor location (“OUT” in the thermostat installation set up menu) and a sensor is attached to the RS2 sensor terminals of the thermostat, the RS2 temperature is used to report outdoor temperature. It is also displayed on the thermostat main screen. See Step 19 to configure for outdoor temperature sensing. E) Indoor sensor connected to RS1 and Outdoor sensor connected to RS2. RS1 replaces the internal sensor. RS2 reads the outdoor temperature. Remote Sensor 1 (RS1) replaces the internal temperature sensor of the thermostat. This allows the thermostat to be installed in a location different than the area where the temperature will be measured. Use ZZSENSAL0400AA. RS2 is used as an outdoor temperature sensor. Use BAYSEN01ATEMPA. See Figure C. 10 If RS2 is set to outdoor location (“OUT” in the thermostat installation set up menu) and a sensor is attached to the RS2 sensor terminals of the thermostat, the RS2 temperature is used to report outdoor temperature. It is also displayed on the thermostat main screen. See Step 19 to configure for outdoor temperature sensing. 13 If necessary, cut the internal jumper wire (JP1). If only one wire is connected to either 24RC or 24RH as shown Do NOT cut JP1 jumper TZEMT500 If wires are connected to both 24RC and 24RH as shown Cut JP1 jumper C 24 1 TO ER MP H T JU C/R CU T R LI SP JP RC 24 RH 24 W1 G Y1 24RC 1 RS 1 RS 2 24RH RS 2 RS /B /O W2 Y2 24RC W1 OR 24RH W1 24RC 1 24RH R PE UM H T J C/R CU IT R L P S W1 1 JP TO O RT PE UM H T J C/R CU IT R L P S JP Cutting the JP1 jumper The jumper is located on back of the thermostat face as shown in the illustration to the right. Cut the jumper using small diagonal cutters being careful not to damage the board. TZEMT400 1 JP 2 C4 MO 2 4 CR 42 HR 1W W 0/2 G 1Y 1 JP 14 2 2 2 CUT JUMPER TO SPLIT RC/RH CUT JUMPER TO SPLIT RC/RH 2Y 1 JP 2 2 2 Route the wires per label on the mounting plate and attach the thermostat face to the wall plate. a. Tuck wiring flat inside the wall plate. ÎÎ It is critical that wires are not bunched together and that they are pressed flat. TZEMT500 TZEMT400 24 b. Carefully align the face plate to the wall plate while aligning pins into wire terminals. c. Once thermostat face is properly aligned, apply pressure at top and bottom of thermostat face until it is secure. 15 CO M 24 RC 24 RH W1 W2/0 G Y1 Y2 24 CO M 24 RC 24 RH W1 W2/0 G Y1 Y2 Wires pressed flat Wires pressed flat Turn power to heating and cooling system back on. The thermostat display should turn on and begin displaying information. If the thermostat display does not come on, go back through the installation steps and look for problems. Pay special attention to steps 3, 4, and 6. 11 System Settings at Thermostat 16 Set Time and Date a. Press the Menu button twice. User Settings 75 MENU MODE 76 H 74 C FAN RUN Scroll down Select button b. Scroll up or down to User Settings (it is the first option), then press the Select button. Menu Selection Scroll up User Settings Usage Graph ESM Setpoints ZWave Install Select Done Scroll down Select button 17 Select Done MENU button c. Scroll up Set Clock Filter Service Maint Service Screen Timeout 11:15 AM Scroll up or down to Set Clock (it is the first option), then press the Select button. d. e. f. g. Press or to highlight the data you want to change. Scroll up or down (+ or -) to make changes. Press the Set button when you are finished. Press the Done button twice to exit the menu. Set Clock Time Date Day Back Scroll up 10 :15 AM 3 / 23 / 09 Mon Set Scroll down Set button If your System Type is: • Gas Furnace - Single Stage, go to step 19 • Gas Furnace - Multistage, perform step 18A • Electric Furnace, perform step 18B • Heat Pump, perform step 18C ÎÎ Note: It may be necessary to go back and review step 3 in the installation section to verify the differences between the system types. 12 18A Gas Furnace - Multistage Mechanical Settings a. Press the MENU button twice. b. Press and hold the two inner buttons for 3 seconds to view Installer Settings. c. Scroll down to System Settings and press the Select button. d. Scroll to Mechanical Settings (it is the first option), then press the Select button. e. Scroll down to 2nd Stage Heat. f. Press the + button to change the setting to Y for Yes. g. If your system also has 2nd stage cooling, scroll down to 2nd Stage Cool and Press the + button to change the setting to Y for Yes. h. Press the Done button 4 times and go to step 19. 11:15 AM 75 MENU MODE Menu button FAN 76 H 74 C RUN Two inner buttons 18B Electric Furnace Mechanical Settings a. Press the MENU button twice. b. Press and hold the two inner buttons for 3 seconds to view Installer Settings. c. Scroll down to System Settings and press the Select button. d. Scroll to Mechanical Settings (it is the first option), then press the Select button. e. Scroll down to Fan Type. f. Press the + button to change the setting Electric. ÎÎ If Single Stage System, press Done 4 times and go to step 19. Mechanical Settings Scroll up Type Heatpump Fan Type Elec C/O Type w/Cool 2nd Stage Heat N Select Done + button Scroll down Select button ÎÎ If Multistage System, continue with steps “g” through “j”. g. Scroll down to 2nd Stage Heat. h. Press the + button to change the setting to Y for Yes. i. If your system also has 2nd stage cooling, scroll down to 2nd Stage Cool and Press the + button to change the setting to Y for Yes. j. Press the Done button 4 times and go to step 19. 18C Heat Pump Mechanical Settings a. Press the MENU button twice. b. Press and hold the two inner buttons for 3 seconds to view Installer Settings. c. Scroll down to System Settings and press the Select button. d. Scroll to Mechanical Settings (it is the first option), then press the Select button. e. Scroll to system Type. f. Press the + button to change the setting to Heat Pump. g. Scroll down to Fan Type. h. Press the + button to change the setting Electric. i. If Coleman, Rheem, or Rudd brand heat pump, scroll to C/O Type and change to With Heat. ÎÎ If Single Stage System, press Done 4 times and go to step 19. ÎÎ If Multistage System, continue with steps “j” through “n”. j. k. l. m. n. Scroll down to 2nd Stage Heat. Press the + button to change the setting to Y for Yes. Scroll down to 2nd Stage Cool. Press the + button to change the setting to Y for Yes. Press the Done button 4 times and go to step 19. 13 19 Optional Remote Temperature Sensors Installation - TZEMT500 Only Remote sensor input RS2 can be configured for use as indoor or outdoor temperature sensing. The factory default setting for RS2 is “IN” for use with remote indoor temperature sensing and/or averaging. To configure RS2 to sense outdoor temperature, complete the following steps: a. b. c. d. e. f. Press the MENU button twice to access the Menu Selection screen. From the Menu Selection screen, press and hold the two inner buttons down for 4 seconds to reach the Installer Settings menu. From the Installer Settings screen, scroll down to Remote Sensors using the Scroll down button and press the Select butt on. From the Remote Sensors screen, select the option for RS2 remote senor location. (IN is the factory default setting) To change RS2 for use as an outdoor temperature sensor, press the + button to change this setting to OUT. Press the Done button three times to return to the home screen. Remote Sensors Up RS2 Location DONE Press DONE button to exit back to installer settings screen. + IN - Scroll menu selection with the Up and Down Down buttons. Press the +/- buttons to change the setting. Perform System Checkout 20 Test Fan Operation a. b. c. d. e. f. Press the FAN button. Scroll to ON. Verify that the system fan starts and moves air. Press the FAN button. Scroll to AUTO. Press the Done button to return to the home screen. 11:15 AM Sys Off Run 75 AUTO AUTO MENU MODE FAN 76 H 74 C RUN Test Cooling Operation (if your system has cooling) a. b. c. d. Press the MODE button. Scroll to COOLING. Press the Done button to return to the home screen. Turn the temperature down using the scroll down button until the new setpoint is below the room temperature. e. Verify that the outdoor unit and the system fan come on and run. Test Heating Operation (if your system has heating) MODE button FAN button CAUTION: Do not run the air conditioner if the outdoor temperature is below 55 degrees F. a. Press the MODE button. b. Scroll to HEATING. c. Press the Done button to return to the home screen. d. Turn the temperature up using the scroll up button until the new setpoint is above the room temperature. e. Verify that the heating system turns on and runs. ÎÎ Note: It may take approximately 5 minutes for the system to start up after switching from COOLING to HEATING mode. There is a built in time delay which will not allow the equipment to turn on until it is ready. The screen will display the word “Wait” until the time delay has finished. This concludes the system checkout. If any part of your system fails to come on when performing this checkout procedure, verify that the correct wires were connected to the wall plate and that each wire is securely attached to the appropriate terminal. Also go back and verify that you have set up the Mechanical Settings to match your System Type. 14 Enroll Thermostat into Schlage LiNK™ System 21 Prepare the bridge for enrollment. ÎÎ Note: If the bridge is already installed with a lock, follow the instructions as they are written in the following steps. If the bridge is not installed, follow the Quick Start Guide publication number P516-288 shipped with the thermostat starter kit. a. b. c. d. Blue light Unplug Ethernet and power cables from bridge. Verify that blue light is blinking. If blue light is solid, battery is dead. Install a quality 9 volt battery. Take bridge to the location where the thermostat is mounted. Battery 22 Enroll the thermostat into the bridge. (Inclusion) If you are using a controller that is not a Schlage LiNKTM bridge, consult the Quick Start Guide that came with the controller to find out how to enroll a new device. 11 :15 a. Hold the bridge within 6 feet (1.8 meters) of the thermostat throughout steps “b” through “f”. ÎÎ After you begin the enrollment process, you have 30 seconds to complete the remainder of the steps. Study the steps below before beginning. b. c. d. e. f. NU Out 75 60 MO DE FA N 76 H 74 C RU N ay tew a G Press and release the plus (+) button on the bridge. Press the MENU button on the thermostat. Scroll down to Z Wave Install, and press the Select button. Press the Yes button to enroll the thermostat. Observe the lights on the bridge. The orange light will blink while enrollment is taking place. Enrollment is complete when the orange light becomes solid. Menu Selection 11:15 AM 75 MENU MODE FAN 76 H 74 C RUN User Settings Usage Graph ESM Setpoints ZWave Install Select Done MENU button 23 AM side “+” Button ME Scroll down Select button Verify enrollment of the thermostat. a. Scroll down to Thermostat Info, and press the Select button. b. Look at the number listed after ZNID. • If the number listed there is anything other than “000”, the thermostat has been successfully enrolled. • If the number listed there is “000”, the thermostat has NOT been successfully enrolled. In this case, repeat step 22 and verify again. c. Press Done button 2 times when finished. Thermostat Info TZEMT500AB32 Ver: 01.00.13 ZVER:02.00.0 ZNID: 013 ZHID: 01.07.37.a7 System Type: Standard Fan Type: Gas ZNID Done 15 24 Establish Online Control of the Thermostat. Schlage LiNK account must be active before continuing. See link.schlage.com for more information. a. b. c. d. Remove the battery from the bridge. Plug the Ethernet and power cord back into the bridge. Log into your account at www.schlagelink.com Click the Climate tab and follow the on screen instructions. Exclusion a. Install a new, high-quality 9-volt battery into the bridge. b. Hold the bridge (1.8 meters) of the thermostat throughout the entire exclusion process. ÎÎ After you begin the exclusion process, you have 30 seconds to complete the remainder of the steps. Study the steps below before beginning. c. d. e. f. g. Press and release the minus (-) button on the bridge. Press the MENU button on the thermostat. Scroll down to Z-Wave Install and press the Select button. Press the Yes button to exclude the thermostat. Observe the lights on the bridge. The orange light will blink while exclusion is taking place. Exclusion is complete when the orange light becomes solid. ÎÎ Z-Wave™ controllers from various manufacturers may support the Z-Wave™ Thermostat General V2 Device class used by the Trane Z-Wave™ Thermostat. If you are using a controller that is not a Schlage bridge, consult the instructions that came with the controller to find out how to enroll a new device. Product Specifications Specification Description Product Model: TZEMT400AB32MAA and TZEMT500AB32MAA Product: Thermostat for Heating and Cooling HVAC System control. Z-Wave™ RF communications enabled Size: 5.7” wide x 4.0” height x 1.2” depth Display: Graphical LCD, 2.75” x 1.5”, 64x128-pixel Backlight: Yes, Blue/white, Controllable, on, off, timeout Contrast: Adjustable on screen Buttons: 6 LEDs: 4 (3 green, 1 red) Power: 24VAC from HVAC System HVAC System Type Compatible: Standard (gas/electric) or Heat Pump Multistage System Compatible: Standard HVAC Systems: 2 stage heating, 2-stage cooling Heat Pump Systems: 3 stage heating (2-compressor, 1 aux heat), 2-stage cooling 16 Heat Pump change over valve: Selectable change over with cool or with heat Communications: Z-Wave™ RF Memory: Non-volatile Clock: 24 hour back-up power provided by super capacitor Operation The model TZEMT400AB32MAA and TZEMT500AB32MAA thermostat provide typical thermostat control of a central heating and cooling HVAC system. These thermostats also features a Z-Wave™ module for remote control. Clock Display Tempurature Display 11:15 AM Sys Off Status Indicator LEDs Run Filter MENU 72 AUTO MODE AUTO FAN Setpoint Up/Down Buttons 77 H 74 C RUN Dynamic Labels Setpoint Display Menu Button System Mode Button Fan Mode Button Schedule Mode Button Normally, the thermostat displays the thermostat control screen as shown above. Item Description Notes Clock Display The current time is displayed in the upper left corner of the main screen. The time will blink when the clock has not been set. See Set Clock on page 20 for more information. Status Indicator LEDs The thermostat has four LEDs that display status information. The LEDs have dynamic labels. See LED Reference on page 30 for more information. Dynamic Labels and Function Control Buttons The buttons are defined by the dynamic labels above each button. As you navigate through menus, the labels for the buttons will change. Setpoint Display and Setpoint Up/Down Buttons The current heat and cool setpoints are displayed. These setpoints may be set using the Z-Wave control system, the thermostat’s internal schedule, or by pressing the Setpoint Up/Down buttons. In HEAT mode, the Setpoint Up/Down buttons change the heat setpoint. In COOL mode, they change the cooling setpoint. In AUTO mode, the buttons change the last call’s heating or cooling setpoint. The setpoints will push each other if they are adjusted to within the minimum heat/cool separation setting. This is normally 3 degrees. The thermostat displays the current temperature as sensed by the internal temperature sensor. The internal temperature sensor can be adjusted as necessary. See Internal Sensor Calibration on page 22 for more information. Temperature Display The internal schedule is disabled by default. See Schedules on page 28 for more information. Minimized Display Mode Optionally, you can set the thermostat to show only the temperature in minimized display mode. This mode can be enabled or disabled in the Users Settings screen. ÎÎ See Screen Timeout on page 21 for more information. 72 17 Thermostat Control Screen Function Control Buttons Button Description Menu Other thermostat menus can be accessed by pressing the MENU button. System Mode Used to change the system mode: 11:15 AM Off: System off Sys Off Heating: Heating only on Run Filter MENU Cooling: Cooling only on 72 AUTO MODE AUTO FAN 77 H 74 C RUN Auto: Heating/Cooling on as necessary Fan Mode Used to change the fan mode: Auto: Fan on when cooling/heating is necessary On: Fan constantly on Schedule Mode Used to change the schedule mode: Hold: System maintains the current temperature setpoints. Schedules are disregarded. Run: Run the system schedule (or Z-Wave controlled schedule) Energy Saving Mode: Temperature setpoints in ESM Setpoints are maintained. See ESM Setpoints on page 23 for more information. 18 Menu Button System Mode Button Fan Mode Button Schedule Mode Button Menu Maps User settings are accessed by pressing the MENU button on the main screen. User Settings Set Clock Installer settings are accessed by pressing the MENU button on the main screen then pressing and holding the two middle buttons until the Installer Settings appear. Installer Settings (Hidden) Filter Service Display Lock Maint Service System Settings Screen Timeout Mechanical Settings F/C Settings Type Sensor Calibration Fan Type Internal C/O Type Remote 1* 2nd Stage Heat Remote 2* Aux Heat 2nd Stage Cool Outside* Backlite/Display Sched Enable Usage Graph Recovery Enable ESM Setpoints H/C Delta Zwave Install H Delta Stg1 ON Thermostat Info H Delta Stg1 OFF H Delta Stg2 ON H Delta Stg2 OFF NOTES: * TZEMT500 Only Select Menu Select Button Done Back one level or to exit Current selection on thermostat H Delta AuxH ON H Delta AuxH OFF C Delta Stg1 ON C Delta Stg2 OFF C Delta Stg2 ON C Delta Stg2 OFF Max Heat SP Max Cool SP Min Run Time Min Off Time Fan Cycler Fan ON Time Fan OFF Time Remote Sensors * RS2 Location * Restore Defaults Schedules (Disabled by Default Heat and Cool Preset: Comfort Preset: Energy Star Copy (small c on each schedule screen) 19 User Settings Set Clock The Set Clock screen allows you to set the thermostat’s internal clock. ÎÎ If the clock has been reset by an extended power outage, the clock display on the thermostat screen will blink. Press the MENU button to go directly to the Set Clock screen. Set Clock + - Time 11 : 15 AM Date 01 / 01 / 09 Day Thu Set the Clock 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Set Clock and press the Select button. 4. Scroll to the item you want to change (hour, minute, day part, month, day, year, day of week). 5. Press the plus (+) or minus (-) buttons to adjust the item. 6. Press the Set button to save the changes. Back Set Filter Service The Filter Service screen will show the accumulated Filter Runtime hours as well as the Service Interval that will be used to trigger a Filter Message. Any type of HVAC operation that causes the HVAC system fan to run will cause the Filter Runtime value to increase. When the Runtime hours equals the Service Interval hours, the Red LED will flash along with a “Filter” message to remind you to replace the filter. Once the filter has been replaced, press the Reset button to reset the Filter Runtime value to zero. Filter Service Filter Runtime Service Interval Done + 184 HRS 300 HRS - Reset View/Reset Filter Runtime 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Filter Service and press the Select button. The Filter Runtime is displayed in hours. 4. To reset the Filter Runtime counter, press the Reset button. ÎÎ The Filter Runtime counter should be reset each time the filter is changed. Change the Filter Service Interval 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Filter Service and press the Select button. 4. Press the plus (+) or minus (-) buttons to adjust the service interval. ÎÎ The service interval can be set between 100 and 4000 hours in 100 hour increments. Disable the Filter Service Interval When the filter service interval is disabled, the runtime counter will continue to count the runtime, but the filter service indicator will never be displayed. 1. 2. 3. 4. 20 Press the MENU button. Scroll to User Settings and press the Select button. Scroll to Filter Service and press the Select button. Press the minus (-) button until Disabled is displayed Maintenance Service The Maintenance Service screen shows the accumulated Heat and Cool Runtime hours as well as the Service Interval that will be used to trigger a Maintenance Message. Any HEAT or COOL type of HVAC operation will cause the respective Runtime values to increase. When the combined HEAT and COOL Runtime hours equals the Service Interval hours, the Red LED will flash along with a “Maint” message to remind you your HVAC system may require periodic maintenance. Press the Menu button to enter the Filter Service screen. The Reset button can be pressed and the HEAT and COOL Runtime values will be reset to zero. Maintenance Service Heat Runtime Cool Runtime 200 HRS 300 HRS Service Interval 3000 HRS Done + - Reset Change the Maintenance Service Interval 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Maint Service and press the Select button. 4. Press the plus (+) or minus (-) buttons to adjust the service interval. ÎÎ The service interval can be set between 200 and 4000 hours in 100 hour increments. Disable the Maintenance Service Interval When the maintenance service interval is disabled, the runtime counter will continue to count the runtime, but the maintenance service indicator will never be displayed. 1. 2. 3. 4. Press the MENU button. Scroll to User Settings and press the Select button. Scroll to Maint Service and press the Select button. Press the minus (-) button until Disabled is displayed Screen Timeout This is the time before any screen reverts to the Minimized Screen (temperature display only), after you stop pushing buttons. Minimized Screen feature is disabled by setting this time to “0”. User Settings Change the Screen Timeout 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Screen Timeout 4. Press the plus (+) or minus (-) buttons to adjust the time (in seconds). ÎÎ The screen time-out can be set between 0 and 120 seconds. Zero (0) is the default setting. When set to Zero (0), the minimized screen feature is disabled. Set Clock Filter Service Maint Service Screen Timeout Done 0 Select Disable the Minimized Display 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Screen Timeout 4. Press the minus (-) button until zero (0) is displayed. 21 F/C Settings The F/C Settings screen is use to select the temperature display mode. Fahrenheit (F) or Celsius (C) are the two available modes. Change the Temperature Mode 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to F/C Settings and press the Select button. 4. Press the plus (+) or minus (-) buttons to change the temperature mode. Select F for Fahrenheit or C for Celsius. F/C Settings F/C Mode Done F + - Internal Sensor Calibration The Sensor Calibration screen is used to change the temperature calibration of the internal temperature sensor. The temperature calibration can be changed by +/- 7 degrees. When the Sensor Calibration screen is selected, the current temperature calibration is displayed. In the example screen, the calibrated temperature is 77 and the number of degrees of offset being applied is 1. Change the Sensor Calibration 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Sensor Calibration and press the Select button. 4. Press the plus (+) or minus (-) buttons to change the sensor calibration. ÎÎ After this screen is closed, it may take a few seconds for the temperature displayed on the main thermostat screen to update to the new temperature. Sensor Calibration Internal Done (77) + 1 - Usage Graph The Usage Graph shows daily heating and cooling runtime hours for a week. The button in the lower right corner will change depending on what is being displayed. When the heating time is displayed, the button will read Cool. When the cooling time is displayed, the button will read Heat Press the Heat/Cool button to display the heating/cooling time. 20 15 10 Heating time (Hrs) 5 Sun Mon Tue Wed Thu Fri Sat Done Cool 22 Backlite/Display The Backlite/Display screen is used to set the backlight time-out and contrast. Backlite Timeout is the time (in seconds) from the last button press to the backlight going out. The time-out can be set between zero (0) and one hundred and twenty (120) seconds. Thirty (30) is the default setting. When set to zero (0), the backlight will remain always on. Contrast sets the contrast level of the LCD display. The contrast can be set between zero (0) and twenty (20). Ten (10) is the default setting. If the display is too light, using a higher number. If dark lines appear in the display, use a lower number. Backlite/Display Backlite Timeout Contrast 60 10 Done - + Adjust the Backlight 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Backlite/Display and press the Select button. 4. Scroll to Backlite Timeout. 5. Press the plus (+) or minus (-) buttons to change the number of seconds. ÎÎ The backlight time-out can be set between 0 and 120 seconds. Thirty (30) is the default setting. When set to Zero (0), the backlight will remain always on. Adjust the Contrast 1. Press the MENU button. 2. Scroll to User Settings and press the Select button. 3. Scroll to Backlite/Display and press the Select button. 4. Scroll to Contrast. 5. Press the plus (+) or minus (-) buttons to change the contrast value. ÎÎ The contrast can be set between 0 and 20. Ten (10) is the default setting. ESM Setpoints Energy Saving Mode (ESM) Setpoints are the setpoints used when the Energy Saving Mode schedule is selected in the Schedule Mode screen. Adjust ESM Setpoints 1. Press the MENU button. 2. Scroll to ESM Setpoints and press the Select button. 3. To adjust the heat setpoint, scroll to ESM - Heat. Press the plus (+) or minus (-) buttons to adjust the setpoint. 4. To adjust the cool setpoint, scroll to ESM - Cool. Press the plus (+) or minus (-) buttons to adjust the setpoint. Energy Saving Mode Setpoings ESM - Heat ESM - Cool Done + 65 80 - 23 Thermostat Info The Thermostat Info screen displays information about the thermostat and the system the thermostat controls. This information will be helpful if you need to contact customer support. Item Description TZEMT500AB32 Model Number Ver: 01.00.10 Firmware version (number may vary) ZVER: 02.00.9 Z-Wave version (number may vary) ZNID: 004 Z-Wave node ID (number may vary) ZHID: 01.07.37.bd Z-Wave Home ID (number may vary) System Type: Standard System type may be Standard or Heat Pump Fan Type: Gas Fan type may be Gas or Elect (electric) Item Done Description TZEMT400AB32 Model Number Ver: 01.00.10 Firmware version (number may vary) ZVER: 02.00.9 Z-Wave version (number may vary) ZNID: 004 Z-Wave node ID (number may vary) ZHID: 01.07.37.bd Z-Wave Home ID (number may vary) System Type: Standard System type may be Standard or Heat Pump Fan Type: Gas Fan type may be Gas or Elect (electric) 24 Thermostat Info TZEMT500AB32 Ver: 01.00.13 ZVER: 02.00.9 ZNID: 004 ZHID: 01.07.37.bd System Type: Standard Fan Type: Gas Thermostat Info TZEMT400AB32 Ver: 01.00.13 ZVER: 02.00.9 ZNID: 004 ZHID: 01.07.37.bd System Type: Standard Fan Type: Gas Done Installer Settings The Installer Settings screen is a hidden screen designed for installer use only. Do not change any settings in this screen unless you are a qualified service technician. Installer Settings Display Lock System Settings Max Heat SP Min Cool SP Done + N 90 60 - Changing these settings will affect the operation of the heating/cooling system. To view and edit these settings: 1. 2. 3. 4. Press the MENU button. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed. Scroll to the setting you want to change. Press the plus (+) or minus (-) button to adjust the setting. Press the Done button when you are finished. Setting Range Default Description Display Lock Y or N N Locks or unlocks the thermostat buttons. When the buttons are locked, the main menu can still be accessed, but no menu options may be selected. The Installer Settings hidden button operation is always operational, allowing Display Lock to be turned off. Max Heat SP 55F to 90F (12C-32C) 90F (32C) Sets the maximum heating setpoint value. Will not ramp or accept setpoints higher than this maximum. Min Cool SP 60F to 99F (15C-37C) 60F (15C) Sets the minimum cooling setpoint value. Will not ramp or accept setpoints lower than this minimum. Minimum Run Time (MRT) 1- 9 Minutes 3 Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display Cool ON or Heat ON while the minimum run time is being enforced. Minimum Off Time (MOT) 5-9 Minutes 5 Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. Thermostat screen will display WAIT when minimum off time is being enforced. Restore Defaults n/a n/a Sets all of the thermostat settings back to the factory defaults. 25 System Settings Changing these settings will affect the operation of the heating/cooling system. To view and edit these settings: 1. 2. 3. 4. 5. ÎÎ Press the MENU button. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed. Scroll to System Settings and press the Select button. Scroll to the setting you want to change. Press the plus (+) or minus (-) button to adjust the setting. Press the Done button when you are finished. Note on Delta Settings: The Delta T Setting is the delta, or difference between, the setpoint and current temp for determining when a heat or cool call comes on. The “delta” is the number of degrees away from the setpoint. Setting Range Default Description Schedule Enable Y or N N When enabled, the local thermostats scheduler function is enabled. Recovery Enable Y or N N The Smart Recovery feature allows heating and cooling systems to gradually recover from an energy-saving set point temperature to a comfort set point temperature. Smart Recovery calculates the time needed to adjust the temperature to the next program setting for the Morning and Evening schedules. When the thermostat is in Smart Recovery mode, the display will show “Recov”. Smart Recovery is an option that allows the HVAC system to attempt to recover from a setback period and reach a desired comfort temperature set point by the beginning of your programmed comfort period. This option allows the choice whether to use Smart Recovery. · Recovery is from a nite setback to morning comfort (period 1), or day setback to evening comfort period (period 3).When in Recovery, the 4th status line will be labeled “Recov” · Recovery works in heat or cool mode · While in recovery, the Aux-Heat stage will never engage · Maximum Smart Recovery time is one hour. H/C Delta 3 - 15 degrees 3 Sets the minimum separation between heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation. Heating Delta Stage 1 ON 1 to 8 degrees 1 Sets the delta from setpoint that stage 1 heating starts. Heating Delta Stage 1 OFF 0 to 8 degrees 0 Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1. Heating Delta Stage 2 ON 1 to 8 degrees 2 Sets the delta from setpoint that stage 2 heating starts. Heating Delta Stage 2 OFF 0 to 8 degrees 0 Sets the delta from setpoint that stage 2 heating stops. Stage 2 turns off at setpoint minus (-) Delta Stage 2. Heating Delta Aux Heat ON 1 to 8 degrees 3 Sets the delta from setpoint that Aux Heat starts. Heating Delta Aux Heat OFF 0 to 8 degrees 0 Sets the delta from setpoint that stage 1 heating stops. Aux Heat turns off at setpoint minus (-) Delta Aux Heat. Cooling Delta Stage 1 ON 1 to 8 degrees 1 Sets the delta from setpoint that stage 1 cooling starts. Cooling Delta Stage 1 OFF 0 to 8 degrees 0 Sets the delta from setpoint that stage 1 Cooling stops. Stage 1 turns off at setpoint plus (+) Delta Stage 1. Cooling Delta Stage 2 ON 1 to 8 degrees 2 Sets the delta from setpoint that stage 2 cooling starts. Cooling Delta Stage 2 OFF 0 to 8 degrees 0 Sets the delta from setpoint that stage 2 Cooling stops. Stage 2 turns off at setpoint plus (+) Delta Stage 2. 26 Mechanical Settings Changing these settings will affect the operation of the heating/cooling system. To view and edit these settings: 1. 2. 3. 4. 5. 6. Press the MENU button. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed. Scroll to System Settings and press the Select button. Scroll to Mechanical Settings and press the Select button. Scroll to the setting you want to change. Press the plus (+) or minus (-) button to adjust the setting. Press the Done button when you are finished. Setting Range Default Description Type Gas/Elec or Heat Pump Gas/Elec Selects HVAC type, Gas/Electric or Heat Pump Fan Type Gas or Elec Gas Selects the Fan type if system is Gas or Electric C/O Type w/Cool or w/ Heat w/Cool Set the Heat pump Changeover type 2nd Stage Heat Y or N N Enables the 2nd Stage Heat operation Aux Heat (HP) Y or N Y Enables the Auxiliary Heat operation. Typically the Aux Heat will be heat-strips in a Heat Pump system 2nd Stage Cool Y or N N Enables the 2nd Stage Cool operation Fan Cycler Settings Changing these settings will affect the operation of the heating/cooling system. To view and edit these settings: 1. 2. 3. 4. 5. Press the MENU button. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed. Scroll to Fan Cycler and press the Select button. Scroll to the setting you want to change. Press the plus (+) or minus (-) button to adjust the setting. Press the Done button when you are finished. Setting Range Default Fan ON Time 0-120 minutes 0 (=OFF) Fan OFF Time 10-120 minutes 10 Description The fan cycler function cycles the HVAC system fan for an ON period followed by an Off period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional Cycler FAN mode is present when pressing the FAN button. ÎÎ NOTE: CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in the AUTO mode. 27 Schedules Scheduling is usually controlled by your Z-Wave system. See the instructions that came with your Z-Wave system for more information. However, scheduling may also be controlled by the thermostat. ÎÎ The Schedules menu is hidden by default, but may be enabled in the Installer Settings. See Enable/Disable the Schedules Menu on page 28 for more information.. The thermostat has a 4 x 7 schedule, meaning the setpoints can be changed up to four times a day each day. Each day has a separate schedule. Schedules may be copied from one day to another day or group of days. See Copy a Day Schedule on page 29 for more information. Select Schedule Heat and Cool Preset:Confort Preset:Energy Star Done Select Enable/Disable the Schedules Menu Because the Schedules menu is disabled by default, you must first enable it before any scheduling can be done at the thermostat. If you want to use your Z-Wave system for scheduling, scheduling must be disabled in the thermostat. 1. 2. 3. 4. ÎÎ Press the MENU button. Press and hold the two middle buttons simultaneously until the Installer Settings menu is displayed. Scroll to Systems Settings and press the Select button. Scroll to Sched Enable and press the plus (+) button to enable scheduling or the minus (-) button to disable scheduling. When scheduling is enabled in the thermostat, a Y will be displayed next to Sched Enable. When scheduling is disabled in the thermostat, an N will be displayed next to Sched Enable. Load a Preset Schedule There are two possible schedules that may be loaded: Preset Comfort and Preset Energy Star. These schedules may not be changed. When a schedule is loaded, it changes the current Heat and Cool schedule settings. You can then edit the Heat and Cool schedule, if necessary. ÎÎ Selecting Preset Comfort or Preset Energy Star schedules will overwrite the current Heat and Cool schedule. 1. 2. 3. 4. Press the MENU button. Scroll to Schedules and press the Select button. Scroll to the schedule you want to load and press the Select button. Press the Yes button. Preset Schedule Description Preset: Comfort This is a preset schedule with mild setbacks, designed to maintain a comfortable temperature. Preset: Energy Star This is a preset schedule with deeper setbacks, designed to conserve energy. 28 Wake Day Eve Sleep Done Monday Schedule Time Heat Cool 06 : 00 A 70 78 08 : 00 A 70 78 04 : 00 P 70 78 10 : 00 P 66 81 c + - Select View the Current Schedule 1. Press the MENU button. 2. Scroll to Schedules and press the Select button. 3. Scroll to Heat and Cool and press the Select button. 4. The schedule for the current day will be displayed. To view other days, press the Next button. Set a Heat and Cool Schedule 1. Press the MENU button. 2. Scroll to Schedules and press the Select button. 3. Scroll to Heat and Cool and press the Select button. 4. The schedule for the current day will be displayed. To view other days, press the Next button 5. To change a setting (hour, minute, day part, heat setpoint or cool setpoint), scroll to that setting using the left () or right () arrow buttons. Then press the plus (+) or minus (-) buttons as necessary. ÎÎ Continue pressing the left () or right () arrow buttons to move to the next line. Copy a Day Schedule 1. Press the MENU button. 2. Scroll to Schedules and press the Select button. 3. Scroll to Heat and Cool and press the Select button. 4. The day of the week is displayed at the top of the screen. Press the Next button until the day you want to copy is displayed. 5. Highlight the small c in the lower right corner by pressing the left arrow () button once. The Next button will change to Copy. 6. Press the Copy button. 7. For each day to which you want to copy the day schedule, change the N (no) to Y (yes). Use the left () or right () arrow buttons to scroll to the day and the use the Yes or No buttons on the side of the screen. 8. Press the Copy button. 29 LED Reference The LEDs on the thermostat may have several different meanings, depending on system, setup and operation. 11:15 AM LED 1 LED 2 LED 3 LED 4 LED Sys Off Run Filter MENU On/Off 72 MODE FAN 77 H 74 C RUN Text Description LED 1 (Green) Off Sys Off HVAC system is OFF System Operation display Off WAIT Minimum Off Time (MOT) delay is active See Installer Settings on page 25 for more information. On Cool On Cooling system is running On Cool On Cooling Min Run Time (MRT) On Heat On Heating system is running On Heat On Heating Minimum Run Time (MRT) See Installer Settings on page 25 for more information. See Installer Settings on page 25 for more information. LED 2 (Green) Off None 1st stage heating or cooling. System Stage display On 2nd Stg Stage 2 heating or cooling is active On Aux Heat Aux Heat – heating is active Flashing E Heat Emergency Heat – heating is active LED 3 (Green) Off Run Schedule mode is active Run/Hold/ESM display On Hold Temperature hold is active On ESM (Energy Savings Mode) temperature preset is active LED 4 (Red) Off None No alerts or messages System Alert display On Filter Filter run timer reached See Filter Service on page 20 for more information. On Maint Maintenance run timer reached See Maintenance Service on page 21 for more information. 30 Warranty Limited Warranty Low Voltage Room Comfort Controls U.S.A. and Canada Only This limited warranty is extended by the manufacturer to the original purchaser and to any succeeding owner of the real property to which the low voltage room comfort control is originally affixed and applies to products purchased and retained for use within the U.S.A. and Canada. The limited warranty period begins when the low voltage room comfort control installation is complete, verified by installer’s invoice or similar document. If installation completion and start-up date cannot be verified by installer’s invoice or similar document, limited warranty coverage begins six (6) months after the date of manufacture based on the low voltage room comfort control serial number. If any part of your low voltage room comfort control fails because of a manufacturing defect within five (5) years from the date the limited warranty period begins, Warrantor will furnish without charge a new low voltage room comfort control. Any local transportation, related service labor, and diagnosis calls, are not included. This limited warranty does not apply if the low voltage room comfort control was purchased direct (i.e. from internet websites or auctions) on an uninstalled basis. Additionally, this limited warranty will not apply unless the low voltage room comfort control is: (1) installed by a licensed or qualified HVAC technician, (2) applied and installed in accordance with the manufacturer’s recommendations in its Installer’s Guide, and (3) in compliance with all industry standards, national, state, and local codes. This limited warranty does not cover your low voltage room comfort control if it is damaged while in your possession; including, but not limited to (1) damage caused by unreasonable use of the low voltage room comfort control, (2) damage from failure to properly maintain the low voltage room comfort control as set forth in the Use and Care manual, (3) damage that is not considered a manufacturing defect, such as acts of God, malfunctions or failures resulting from fire, water, storms, lightning, earthquake, theft, riot, misuse, abuse, increased utility usage costs, (4) performance problems due to improper selection/equipment match-up, installation, or application, or (5) failures, defects, or damages (including, but not limited to, any failure or loss of data) caused by any third party product, service, or system connected or used in conjunction with your low voltage room comfort control. THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESSED OR IMPLIED, IN LAW OF IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages. If you wish further help or information concerning this limited warranty, contact: Residential Systems 6200 Troup Highway Tyler, TX 75707 Attention: Consumer Relations Or visit our website: www.trane.com/residential TW-1019-5109 31 ©2010 Schlage Lock Company Printed in U.S.A. P516-275 Rev. 07/10-b Trane 6200 Troup Highway Tyler, TX 75707 www.trane.com Literature Order Number File number Supersedes Date 18-HD39D1-4 18-HD39D1-4 18-HD39D1-3 6/10 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.