CABLES _ SIGNAL CABLES READOUTS, DATALOGGERS & ACCESSORIES CABLES_EN_01_12/2014 CABLES SIGNAL CABLES This model of cables are designed for geotechnical, structural and hydrological applications that require good mechanical and waterproofing characteristics but do not need flame retardant materials such as concrete, earth and rockfill dams, embankments, landslides and unstable slopes. Sisgeo PVC signal cables comply with the following international standards (if applicable): IEC 60540 IEC 60811 IEC 60538 IEC 60332.1-2 EN-50363 IPCEA S-61-402 NEMA WC5 www.sisgeo.com Test methods for insulation and sheath of electric cables and cords - Elastometric and Thermoplastic compounds Test methods for insulation and sheath of electric cables and cords - Test for determining the mechanical properties Method of test for polyethylene insulation and sheath Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame Insulating, sheathing and covering materials for low voltage energy cables Thermoplastic-Insulated wire and cable SIGNAL CABLES 2 SIGNAL CABLES Cable layout Single conductor Conductor insulation sheath MODEL 0WE104SG0pv MODEL 0WE104k00pv MODEL 0WE104x20pv 2 twisted pairs 22 AWG (4x0.34 mm²) tinned copper type Cu ETP 5649/88 2 twisted pairs 22 AWG (4x0.34 mm²) tinned copper type Cu ETP 5649/88 2 twisted pairs 22 AWG (4x0.34 mm²) tinned copper type Cu ETP 5649/88 polyolefin polyolefin polyolefin - Stress member or armour Overall screen Inner jacket aluminium/polyester tape - - aluminium/polyester tape - aluminium/polyester tape polyolefin PVC, grey Outer jacket PVC, black Overall diameter (mm) 4.8 ± 0.2 7.6 ± 0.2 7.7 ± 0.2 Temperature operating range from -30°C to +80°C from -30°C to +80°C from -30°C to +80°C Conductor resistance (Ω/Km at 20°C) < 58.7 < 58 < 58 Insulation resistance (MΩxKm) > 8.000 > 8.000 > 8.000 Weight (Kg/Km) 37.5 80 89 Minumum bending radius 10 x outer diameter 10 x outer diameter 10 x outer diameter MODEL 0WE116000pv MODEL 0WE132000pv 8 twisted pairs 24 AWG (16x0.22 mm²) tinned copper type Cu ETP 5649/88 16 twisted pairs 24 AWG (32x0.22 mm²) tinned copper type Cu ETP 5649/88 Conductor insulation sheath polyolefin polyolefin Overall screen Outer jacket aluminium/polyester tape PVC, black aluminium/polyester tape PVC, black Overall diameter (mm) 8.2 ± 0.2 11.2 ± 0.2 Temperature operating range from -30°C to +80°C from -30°C to +80°C Conductor resistance (Ω/Km at 20°C) < 88 < 88 Insulation resistance (MΩxKm) > 8.600 > 8.600 Weight (Kg/Km) 87 kg 154 kg Minumum bending radius 10 x outer diameter 10 x outer diameter Cable layout Single conductor PVC, grey galvanized steel wire braid (max applicable load 1000 N) All the information in this document is the property of Sisgeo S.r.l. and should not be used without permission from Sisgeo S.r.l. We reserve the right to change our product without prior notice. SISGEO s.r.l. Via F. Serpero 4/F1 20060 Masate (MI) Italy Phone +39 02 95764130 Fax +39 02 95762011 info@sisgeo.com www.sisgeo.com ADditional Support SISGEO offers on-line assistance service to the Customers in order to maximize the performance of the system and training on the correct use of the instrument/readout. For more information contact mail: assistance@sisgeo.com SIGNAL CABLES 3 CABLES_EN_01_12/2014 CABLES