signal cables

advertisement
CABLES
_ SIGNAL
CABLES
READOUTS,
DATALOGGERS
& ACCESSORIES
CABLES_EN_01_12/2014
CABLES
SIGNAL CABLES
This model of cables are designed for geotechnical, structural and hydrological
applications that require good mechanical and waterproofing characteristics but
do not need flame retardant materials such as concrete, earth and rockfill dams,
embankments, landslides and unstable slopes.
Sisgeo PVC signal cables comply with the following international standards
(if applicable):
IEC 60540 IEC 60811 IEC 60538 IEC 60332.1-2
EN-50363 IPCEA S-61-402 NEMA WC5
www.sisgeo.com
Test methods for insulation and sheath of electric cables and cords - Elastometric and Thermoplastic compounds
Test methods for insulation and sheath of electric cables and cords - Test for determining the mechanical properties
Method of test for polyethylene insulation and sheath
Tests on electric and optical fibre cables under fire conditions
Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame
Insulating, sheathing and covering materials for low voltage energy cables
Thermoplastic-Insulated wire and cable
SIGNAL CABLES 2
SIGNAL CABLES
Cable layout
Single conductor
Conductor insulation sheath
MODEL 0WE104SG0pv
MODEL 0WE104k00pv
MODEL 0WE104x20pv
2 twisted pairs
22 AWG (4x0.34 mm²)
tinned copper
type Cu ETP 5649/88
2 twisted pairs
22 AWG (4x0.34 mm²)
tinned copper
type Cu ETP 5649/88
2 twisted pairs
22 AWG (4x0.34 mm²)
tinned copper
type Cu ETP 5649/88
polyolefin
polyolefin
polyolefin
-
Stress member or armour
Overall screen
Inner jacket
aluminium/polyester tape
-
-
aluminium/polyester tape
-
aluminium/polyester tape
polyolefin
PVC, grey
Outer jacket
PVC, black
Overall diameter (mm)
4.8 ± 0.2
7.6 ± 0.2
7.7 ± 0.2
Temperature operating range
from -30°C to +80°C
from -30°C to +80°C
from -30°C to +80°C
Conductor resistance (Ω/Km at 20°C)
< 58.7
< 58
< 58
Insulation resistance (MΩxKm)
> 8.000
> 8.000
> 8.000
Weight (Kg/Km)
37.5
80
89
Minumum bending radius
10 x outer diameter
10 x outer diameter
10 x outer diameter
MODEL 0WE116000pv
MODEL 0WE132000pv
8 twisted pairs
24 AWG (16x0.22 mm²)
tinned copper
type Cu ETP 5649/88
16 twisted pairs
24 AWG (32x0.22 mm²)
tinned copper
type Cu ETP 5649/88
Conductor insulation sheath
polyolefin
polyolefin
Overall screen
Outer jacket
aluminium/polyester tape
PVC, black
aluminium/polyester tape
PVC, black
Overall diameter (mm)
8.2 ± 0.2
11.2 ± 0.2
Temperature operating range
from -30°C to +80°C
from -30°C to +80°C
Conductor resistance (Ω/Km at 20°C)
< 88
< 88
Insulation resistance (MΩxKm)
> 8.600
> 8.600
Weight (Kg/Km)
87 kg
154 kg
Minumum bending radius
10 x outer diameter
10 x outer diameter
Cable layout
Single conductor
PVC, grey
galvanized steel wire braid
(max applicable load 1000 N)
All the information in this document is the property of Sisgeo S.r.l. and should not be used without permission from Sisgeo S.r.l.
We reserve the right to change our product without prior notice.
SISGEO s.r.l.
Via F. Serpero 4/F1
20060 Masate (MI) Italy
Phone +39 02 95764130
Fax +39 02 95762011
info@sisgeo.com
www.sisgeo.com
ADditional Support
SISGEO offers on-line assistance service to the Customers in order to
maximize the performance of the system and training on the correct
use of the instrument/readout.
For more information contact mail: assistance@sisgeo.com
SIGNAL CABLES 3
CABLES_EN_01_12/2014
CABLES
Download