COOPER LIGHTING - METALUX ® DESCRIPTION The Paralux III Series features recessed aesthetics and the latest in energy efficient technology. The luminaire incorporates a nominal 3" deep precision cell louver into a 4-3/4" deep para-contoured fixture housing. This combination creates a total high performance parabolic optical assembly for optimum performance. The series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories for application versatility. The high performance luminaire is designed to offer maximum efficiency and performance for today’s unique interior specifications. The Paralux III series is an excellent choice for commercial office spaces, schools, hospitals or retail merchandising areas. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S A…Construction B … E l e c t r i c a l ** D …H i n g i n g / L a t ch i n g 4-3/4" deep, para-contoured housing, die formed of code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/wireway cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have labor saving integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. Positive spring loaded, self locking, steel latches. Safety lock T-hinges allow hinging and latching from either side. A E…Louver C…Finish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. B Die formed of low iridescent, vertical grain anodized aluminum. Finish is Anodic oxide coating. Accurate precision parabolic cells are held in place with interlocking feature. True-cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by polyethylene cover. E C D 2EP3GAX 328T8 332 18, 24 Cell 2 ' X 4 ' PA R A B O L I C 3 T8 LAMPS SEMI-SPECULAR, SPECULAR OR WHITE PA I N T E D L O U V E R 4-3/4" [121mm] Paralux III Recessed Static or A i r S u p p l y Tr o f f e r 23-3/4" [603mm] L A M P C O N F I G U R AT I O N S M O U N T I N G D ATA 3 LAMP Access Plate 7/8" [22mm] K.O. 7/8" [22mm] K.O. (4) E N E R G Y D ATA 3 LAMP – 18/24 CELL Input Watts: 4-3/4" [121mm] 2-5/8" [67mm] 23-3/4" [603mm] EB Ballast & STD Lamps 328T8 (67) 332 (81) 7" 7" [178mm] [178mm] 23-3/4" [603mm] Luminaire Efficacy Rating LER = FP-77 Catalog Number: 2EP3GAX-332S36I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.11 4-5/8" [119mm] 3" [77mm] 48" [1217mm] 7-7/8" [201mm] **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. C E I L I N G C O M PAT I B I L I T Y G Grid/Lay-in Standard T Concealed T T Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G or T G or T F MZ MZ (Verify compatibility/ consult Pre Sales Technical Support.) COOPER LIGHTING LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090191 2EP3GAX T8 P H OTO M E T R I C S Candlepower 2EP3GX-332S38I Electronic Ballast F32T8/35K Lamps 3100 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.5 x mounting height Efficiency 66.3% Test Report: 220P212 LER = FP-74 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.24 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2238 2239 2198 2135 2051 1955 1845 1719 1574 1414 1248 1064 846 546 250 101 47 16 0 2EP3GX-332S36I-EB82 C a n d l e p o w e r Electronic Ballast Across ⊥ 2238 2270 2306 2333 2343 2329 2287 2211 2246 2060 1678 1258 1043 756 421 143 54 16 0 45° 2238 2252 2250 2227 2185 2123 2041 1941 1817 1689 1536 1220 818 506 255 106 48 16 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 79 70 62 55 49 44 40 36 33 30 28 79 68 58 50 44 38 34 30 27 25 22 79 66 55 46 39 34 30 26 23 21 19 77 71 66 60 55 51 47 43 40 38 35 77 69 61 54 48 43 39 35 32 30 27 77 67 57 50 43 38 34 30 27 25 22 77 65 54 46 39 34 30 26 23 21 19 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 1830 3053 5433 6167 6167 %Lamp 19.7 32.8 58.4 66.3 66.3 Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.5 x mounting height Efficiency 69.1% Test Report: 220P211 LER = FP-77 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.11 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2243 2246 2213 2160 2084 1992 1884 1762 1619 1463 1298 1120 921 673 373 128 54 19 0 Across ⊥ 2243 2275 2311 2340 2354 2342 2303 2231 2268 2080 1670 1244 1052 771 432 148 55 15 0 45° 2243 2258 2263 2248 2215 2163 2089 1998 1880 1759 1619 1310 891 583 339 132 54 18 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 79 73 67 62 57 52 48 45 41 39 36 F32T8/35K Lamps 3100 Lumens %Fixture 29.7 49.5 88.1 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 74 66 59 52 47 42 38 34 31 29 27 71 64 57 50 45 41 37 33 31 28 26 68 61 55 49 44 39 36 33 30 27 25 74 64 56 48 42 37 33 30 27 24 22 74 63 53 45 39 34 29 26 23 21 19 71 62 54 47 41 36 32 29 26 24 22 71 61 52 44 38 33 29 26 23 21 19 10% 30 10 68 60 53 46 40 36 32 29 26 24 22 68 59 51 44 38 33 29 26 23 21 19 0% 0 66 58 49 42 36 32 28 24 22 20 18 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 69 68 74 71 76 73 79 76 80 76 Height Across 8.5’ 10.0’ 65 64 70 67 73 71 76 72 77 74 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 82 76 70 64 59 54 50 46 43 40 37 82 73 65 57 51 45 41 37 34 31 28 82 71 60 52 45 39 35 31 28 25 23 82 68 57 48 41 35 31 27 24 21 19 80 74 68 62 57 52 48 45 42 39 37 80 72 63 56 50 45 40 36 33 30 28 80 69 59 51 44 39 34 31 28 25 23 80 67 56 47 40 35 30 27 24 21 19 20% 50% 50 30 10 30% 50 30 10 50 77 69 61 54 48 43 39 35 32 30 27 74 66 59 52 46 42 38 34 31 29 27 71 64 57 50 45 41 37 33 31 28 26 77 67 58 50 43 38 34 30 27 25 23 77 65 55 46 40 34 30 27 24 21 19 74 65 56 49 42 37 33 30 27 24 22 74 63 53 46 39 34 30 26 24 21 19 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1850 3102 5569 6428 6428 %Lamp 19.9 33.4 59.9 69.1 69.1 %Fixture 28.8 48.3 86.6 100.0 100.0 10% 30 10 Height Along 8.5’ 10.0’ 69 68 74 71 76 73 79 76 80 76 71 62 54 47 42 37 33 29 27 24 22 0% 0 71 61 52 45 39 34 30 26 23 21 19 69 60 51 43 37 32 28 25 22 20 18 Height Across 8.5’ 10.0’ 65 64 70 67 73 71 76 72 77 74 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : 2 E P 3 G A X - 3 3 2 S 3 6 I - U N V- E B 8 1 - U Rating Blank= Standard NY=New York City Rated ATW-SW4= Chicago Rated HR=Heat Removal (1) Width 2=2' Width Voltage (5) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277(6) Number of Lamps (4) 3 lamps Wattage (Length) 28T8=28W T8 (48") (7) 32=32W T8 (48") Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (8) Louver Color S=Silver W=White Cell Configuration 36=3 Rows of 6, 18 Cell 38=3 Rows of 8, 24 Cell EP=Paralux Louver 3=3" Louver Depth Trim Type G=Grid/Lay-in (Standard) G or T=Concealed T (9) G or T=Slot Grid (2) (9) F=Aluminum Flange Trim (10) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) (1) Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard (Silver Only) MI=Specular/Mirrored (Low Iridescent) (Silver Only) P=Painted (White only) Option – Aluminum Flange Trim (10) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row (2) Lamps Installed Blank=No Lamps Installed L8830=T8 Lamp, 28W and 32W, 3000K (7) L8835=T8 Lamp, 28W and 32W, 3500K (7) L8841=T8 Lamp, 28W and 32W, 4100K (7) L8835HL=T8 Lamp, 32W, 3500K, 3100 Lumens L8841HL=T8 Lamp, 32W, 4100K, 3100 Lumens Ballast Type (5) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Ballast Distortion < 10% 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Packaging Options U=Unit Pack PAF=Painted After PAL=Job Pack, Fabrication out of carton RIF1=Radio PALC=Job Pack, Interference in carton Suppressor 20GA/REP=20 Gauge Riveted Endplates. For use in New York City. RLS=Rotor-Lock Socket (T8 Lamps Only) (Additional options available. See Accessory Section) ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 S H I P P I N G I N F O R M AT I O N Catalog No. Wt. 2EP3GAX-332S36I 2EP3GAX-328T8S36I 2EP3GAX-332S38I 2EP3GAX-328T8S38I 42 42 42 42 lbs. lbs. lbs. lbs. (3) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. Convertibility applies to housing only, appropriate (4) (5) (6) shielding media assemblies must be utilized. Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not available when specifying emer(7) (8) (9) gencies, voltage must be specific. When utilizing 28W T8 lamps, HPT8 Ballast must be speficied. Fixtures equipped with “EL” option have 5-1/2" housing depth. G: Louver is recessed by 5/16" in Concealed T or Slot (10) Grid. T: Louver height= 3", Housing depth= 5-1/2" Specify row configuration, type in catalog number when ordering complete fixture. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 10/09 ADF090191