Technical Data TD00808001E Effective November 2012 Supersedes February 2007 Pringle switch and replacement parts Contents DescriptionPage Product description. . . . . . . . . . . . . . . . . . . . . . . . Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pringle switch information. . . . . . . . . . . . . . . . . . . Catalog numbering systems.. . . . . . . . . . . . . . . . . Pringle switch replacement parts.. . . . . . . . . . . . . Cross-reference. . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 3 4 5 5 Technical Data TD00808001E Effective November 2012 Pringle switch and replacement parts Product description Products include: Eaton’s PringleE switches have helped pioneer development of high-quality electrical products for commercial and industrial applications since 1891. Our commitment to engineering excellence and reputation for quality have made us a recognized leader in the electrical industry, and today you’ll find our electrical products in use throughout the U.S., Canada and most of the world’s major markets. Eaton’s Pringle bolted contact switches were the first in the industry and are a worldwide standard in high-current switching applications. They are custom-built and used in many heavy-duty applications, and are suitable for use in ULT 891 switchboards. Manually operated (QA)—UL Listed Manually operated contact switch with quick-positive switching action. It can be top or bottom fed and supplied in a NEMA 1, 3R, 4, or 12 enclosure. Electrical trip (CBC)—UL Listed Contact switch with charge-before-close mechanism. Can be manually or electrically tripped. Optional blown fuse detector and phase failure relay with capacitor trip is available. Fault protector electrical trip (FP)—UL Listed The FP combines the features of a CBC switch but includes an integrated zero-sequence sensor and a ground fault. Features • 480V UL • 600V CSAT • 800–4000A • 5000 and 6000A available (not UL Listed) • 200 kAIC and 100% rated with Class L fuses • Top or bottom feed • Two-, three- or four-pole • Optional blown fuse detection and protection • Quick-positive switching action • Manual or electrically operated mechanism • 12X Make / 6X Break contact rating To place an order for a Pringle bolted pressure switch, please call • Can be supplied in NEMAT 1, 3R, 4, or 12 enclosures 1-800-356-1243. 2 Electrically operated electrical trip (EO)—not UL Listed eaton corporation www.eaton.com The EO combines the features of a CBC switch but includes an operator with a linear motor that electrically closes the switch while charging the stored energy mechanism for stored energy trip. Pringle Mill Switch (PMS)—not UL Listed Manually operated contact switch with quick-positive switching action. Comes in a NEMA 12 or 4 enclosure with a side-operated mechanism. Can be fused or non-fusible, two- or three-pole configurations. Technical Data TD00808001E Pringle switch and replacement parts Effective November 2012 Pringle switch information Table 1. Electrical Trip Switches (CBC) Type Feed Amperes Old Pringle Catalog Number CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC CBC Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Top Top Top Top Top Top Top Top Top 800 1200 1600 2000 2500 3000 4000 5000 6000 800 1200 1600 2000 2500 3000 4000 5000 6000 CBC-0833-B-120 CBC-1233-B-120 CBC-1633-B-120 CBC-2033-B-120 CBC-2533-B-120 CBC-3033-B-120 CBC-4033-B-120 CBC-5033-B-120 CBC-6033-B-120 QA-0833-CBC-120 QA-1233-CBC-120 QA-1633-CBC-120 QA-2033-CBC-120 QA-2533-CBC-120 QA-3033-CBC-120 QA-4033-CBC-120 QA-5033-CBC-120 QA-6033-CBC-120 Table 3. Manually Operated Switches (QA) Vista Catalog Number Type Feed Amperes Old Pringle Catalog Number Vista Catalog Number CB0833B120480 CB1233B120480 CB1633B120480 CB2033B120480 CB2533B120480 CB3033B120480 CB4033B120480 CB5033B120480 CB6033B120480 CB0833T120480 CB1233T120480 CB1633T120480 CB2033T120480 CB2533T120480 CB3033T120480 CB4033T120480 CB5033T120480 CB6033T120480 QA QA QA QA QA QA QA QA QA QA QA QA QA QA QA QA QA QA Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Bottom Top Top Top Top Top Top Top Top Top 800 1200 1600 2000 2500 3000 4000 5000 6000 800 1200 1600 2000 2500 3000 4000 5000 6000 QA-0833-B QA-1233-B QA-1633-B QA-2033-B QA-2533-B QA-3033-B QA-4033-B QA-5033-B QA-6033-B QA-0833 QA-1233 QA-1633 QA-2033 QA-2533 QA-3033 QA-4033 QA-5033 QA-6033 QA0833B480 a QA1233B480 a QA1633B480 a QA2033B480 a QA2533B480 a QA3033B480 a QA4033B480 a QA5033B480 a QA6033B480 a QA0833T480 a QA1233T480 a QA1633T480 a QA2033T480 a QA2533T480 a QA3033T480 a QA4033T480 a QA5033T480 a QA6033T480 a a 208V system also available. For other system voltages, see Table 5 on Page 4. Table 2. Fault Protectors (FP) Table 4. Electrically Operated Switches Type Feed Amperes Old Pringle Catalog Number FP FP FP FP FP FP FP FP FP FP FP FP FP FP Bottom Bottom Bottom Bottom Bottom Bottom Bottom Top Top Top Top Top Top Top 800 1200 1600 2000 2500 3000 4000 800 1200 1600 2000 2500 3000 4000 FP-0834-B-480 FP-1234-B-480 FP-1634-B-480 FP-2034-B-480 FP-2534-B-480 FP-3034-B-480 FP-4034-B-480 FP-0834-480 FP-1234-480 FP-1634-480 FP-2034-480 FP-2534-480 FP-3034-480 FP-4034-480 Vista Catalog Number FP0834B120480 FP1234B120480 FP1634B120480 FP2034B120480 FP2534B120480 FP3034B120480 FP4034B120480 FP0834T120480 FP1234T120480 FP1634T120480 FP2034T120480 FP2534T120480 FP3034T120480 FP4034T120480 Type Feed Amperes Old Pringle Catalog Number Vista Catalog Number a FP FP FP FP FP FP FP FP FP FP FP FP FP Bottom Bottom Bottom Bottom Bottom Bottom Bottom Top Top Top Top Top Top 800 1200 1600 2000 2500 3000 4000 800 1200 1600 2000 2500 3000 CBC-0833-480-B-EO CBC-1233-480-B-EO CBC-1633-480-B-EO CBC-2033-480-B-EO CBC-2533-480-B-EO CBC-3033-480-B-EO CBC-0833-480-EO CBC-1233-480-EO CBC-1633-480-EO CBC-2033-480-EO CBC-2533-480-EO CBC-3033-480-EO CBC-4033-480-EO EO0833B120480 EO1233B120480 EO1633B120480 EO2033B120480 EO2533B120480 EO3033B120480 EO0833T120480 EO1233T120480 EO1633T120480 EO2033T120480 EO2533T120480 EO3033T120480 EO4033T120480 a Substitute 480 with 208 when referencing a different system voltage. eaton corporation www.eaton.com 3 Technical Data TD00808001E Pringle switch and replacement parts Effective November 2012 Catalog numbering systems Table 5. Vista Catalog Numbering System—CB, QA, FP, EO CB 08 3 3 B 120 480 K G P AO CT 5 6 NF Switch Type Additional Option CB =CBC QA =QA FP =FP EO a=EO Auxiliary Contact Number of Poles 5=1NO/1NC 7=2NO/2NC 2=Two-pole 3=Three-pole 4=Four-pole Amperes 08= 800A 12= 1200A 16= 1600A 20= 2000A 25= 2500A 30= 3000A 40= 4000A 50= 5000A 60= 6000A NF=Non-fused g Option 6 = With handle suitable to meet 6-foot 6-inch requirements Control Power Transformer b Wire Type CT =With control power transformer f 2=Two-wire 3=Three-wire 4=Four-wire Blown Fuse Detector (BFD) A =BFD with three normally ON lights (does NOT trip) AO= BFD with three normally OFF lights (does NOT trip) AX= BFD with NO lights (trips switch) A9 = BFD with three normally ON lights (trips switch) AR= BFD with three normally OFF lights (trips switch) Feed Entry B= Bottom T= Top Voltage Control b Phase Failure Relay b 120 =120V c R= Single-phase voltage relay with capacitor trip device (SPVR) System Voltage d 208 e= 208V 480 =480V 600 =600V Ground Fault b G = Ground fault with control power transformer GNX = Ground fault without control power transformer Interlock K =Key interlock provisions a Not UL Listed. A separate control box might be required when adding accessories. b Not an option with QA type switches. GF option includes control power transformer. c 110 Vdc and 125 Vdc also available. Please contact the plant. d For different system voltage requirements, please contact the plant. e For QA switches, please use a 480V system catalog number when referencing a 208V system. f Only applicable if ordering a CPT only, without ground fault. g Only available with QA switches and in a top-feed configuration. Table 6. Vista Catalog Numbering System—Pringle Mill Switch PMS 08 3 3 NF T B W Switch Type PMS= Pringle Mill Switch Amperes 08= 800A 12= 1200A 16= 1600A 20= 2000A 25= 2500A 30= 3000A 40= 4000A Option c Number of Poles 2=Two-pole a 3=Three-pole b Wire Type 2=Two-wire a 3=Three-wire b Feed Entry B= Bottom T=Top Feed Exit B= Bottom T=Top Fusing F =Fusible NF=Non-fusible a 250 Vdc. b 480 Vac. c Additional available accessories/options—door interlock, special nameplates, special paint, auxiliary contacts. Please inquire at the Cleveland, TN, plant. 4 eaton corporation www.eaton.com W = With viewing window Technical Data TD00808001E Pringle switch and replacement parts Effective November 2012 Pringle switch replacement parts Cross-reference Replacement products Table 7. Cross-Reference • Pole yoke assembly • Arc chute assembly Description • Arcing parts • Auxiliary contact • BFD—actuator • Capacitor • Clamping mechanism • Coil/solenoid assembly • Coil assembly • Coil only • Deadfront • EO motor assembly • Ground fault relay • K interlock kit • Limit switch • Micro switch • Pan assembly • Pole assembly • Sensor • SPVR—single-phase voltage relay • Transformers • Handles Three-Pole Yoke Assembly 800A Bottom and top 1200 and 2000A Bottom and top 2500A Bottom and top 3000 and 4000A Bottom and top 5000 and 6000A Bottom and top Arc Chute Assembly Single-Pole Bottom and top Arcing Parts 800A, 480V Top 1200A, 480V Top 1600A, 480V Top 2000A, 480V Top 2500A, 480V Top 3000–6000A, 480V Top 800A, 600V Top 1200A, 600V Top 1600A, 600V Top 2000 and 2500A, 600V Top 3000–6000A, 600V Top Auxiliary Contact Replacement auxiliary contact Bottom and top switch (std. 5 and 7) #5 Auxiliary contact kit Bottom and top (1NO/1NC) #7 Auxiliary contact kit Bottom and top (2NO/2NC) Blown Fuse Detection Bussmann blown fuse Bottom and top actuator #KAZ Blown fuse kit Bottom and top Capacitor ITI CTD-2 capacitor Bottom and top Clamping Mechanism 800A, 480V Top 1200A, 480V Top 1600A, 480V Top 2000A, 480V Top 2500A, 480V Top 3000A, 480V Top 4000A, 480V Top 5000A, 480V Top Coil Assembly/Solenoid Assembly 120V solenoid sub-assembly Bottom and top 120V coil only Bottom and top 110 Vdc coil only Bottom and top To place an order for replacement parts, please call 1-800-356-1243. Feed Type Vista Style/Catalog Number QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC S10035 S10036 S10037 S10038 S10039 QA and CBC S10075 QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC S10048 S10049 S10050 S10051 S10052 S10053 S10054 S10055 S10056 S10057 S10058 QA and CBC 6533 QA and CBC S0005 QA and CBC S0007 QA and CBC 6585 QA and CBC S0001 QA and CBC 6415 QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC S10040 S10041 S10042 S10043 S10044 S10045 S10046 S10047 QA and CBC QA and CBC QA and CBC S12013 6524 6528 eaton corporation www.eaton.com 5 Technical Data TD00808001E Pringle switch and replacement parts Effective November 2012 Table 7. Cross-Reference, Continued Table 7. Cross-Reference, Continued Description Feed Type Deadfront/Operating Mechanism 800–2000A Bottom and top CBC 2500A Bottom and top CBC 3000 and 4000A Bottom and top CBC 800–2000A (with key Bottom and top CBC interlock provisions) 2500A (with key Bottom and top CBC interlock provisions) 3000–4000A (with key Bottom and top CBC interlock provisions) 5000 and 6000A (with key Bottom and top CBC interlock provisions) 5000 and 6000A (QA CBC D/F) Bottom and top CBC 800A Bottom and top QA 1200 and 2000A Bottom and top QA 2500A Bottom and top QA 3000 and 4000A Bottom and top QA 5000 and 6000A (service D/F) Bottom and top QA 800–2000A, special Bottom and top QA 2500A, special Bottom and top QA 3000–4000A, special Bottom and top QA 3000 and 4000A (with key Bottom and top QA interlock provisions) Ground Fault Relay BGFL-159-1200 ITI ground Bottom and top QA and CBC fault relay K Interlock Kit 800–4000A Bottom and top QA 800–4000A Bottom and top CBC Switch Replacement limit switch Bottom and top QA and CBC MT 4RV A 28 micro switch Bottom and top QA and CBC Pan Assembly—Spvr Relay and Cpt—480 Vac 800–2000A Bottom CBC 2500A Bottom CBC 3000–4000A Bottom CBC 800–2000A Top CBC 2500A Top CBC 3000–4000A Top CBC Pan Assembly—GF and SPVR Relay and CPT—480 Vac 800–2000A Top CBC 2500A Top CBC 3000–4000A Top CBC 800–2000A Bottom CBC 2500A Bottom CBC 3000–4000A Bottom CBC Pan Assembly—Gf and Cpt—480 Vac 800–2000A Top CBC 2500A Top CBC 3000–4000A Top CBC 800–2000A Bottom CBC 2500A Bottom CBC 3000–4000A Bottom CBC 6 eaton corporation www.eaton.com Vista Style/Catalog Number P50014 P50015 P50016 P51080 P51081 P51082 S10062 S10068 S10064 S10065 S10066 S10067 S20501 S10069 S10070 S10071 S10079 4276 S1805R S1806R 6534 6536 P55325 P55326 P55327 P51724 P55421 P51726 P55422 P55423 P55424 P51750 P55437 P55425 P55502 P55503 P55504 P55508 P55509 P55510 Description Feed Pan Assembly—Gf and Cpt—208 Vac 800–2000A Top 2500A Top 3000–4000A Top 800–2000A Bottom 2500A Bottom 3000–4000A Bottom Pole Assembly 800A, 480V Top 1200A, 480V Top 1600A, 480V Top 2000A, 480V Top 2500A, 480V Top 3000A, 480V Top 4000A, 480V Top 5000A, 480V Top 800A, 480V Bottom 1200A, 480V Bottom 1600A, 480V Bottom 2000A, 480V Bottom 2500A, 480V Bottom 3000A, 480V Bottom 4000A, 480V Bottom 5000A, 480V Bottom 800A, 600V Bottom 1200A, 600V Bottom 1600A, 600V Bottom 2000A, 600V Bottom 2500A, 600V Bottom 3000A, 600V Bottom 4000A, 600V Bottom 800A, 600V Top 1200A, 600V Top 1600A, 600V Top 2000A, 600V Top 2500A, 600V Top 3000A, 600V Top 4000A, 600V Top Sensor 800–2000A (8.0 x 18.0) Bottom and top 2500A (8.0 x 24.0) Bottom and top 3000 and 4000A (8.0 x 36.0) Bottom and top 800–2000A, split core Bottom and top (8.0 x 18.0) 2500A, split core (8.0 x 24.0) Bottom and top 3000–4000A, split core Bottom and top (8.0 x 36.0) Type Vista Style/Catalog Number CBC CBC CBC CBC CBC CBC P55505 P55506 P55507 P55511 P55512 P55513 QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC QA and CBC S10005 S10006 S10007 S10008 S10009 S10010 S10011 S10012 S10013 S10014 S10015 S10016 S10017 S10018 S10019 S10020R S10021 S10022 S10023 S10024 S10025 S10026 S10027 S10028 S10029 S10030R S10031 S10032 S10033 S10034 CBC CBC CBC CBC 4296 4297 4298 4296SC CBC CBC 4297SC 4298SC Technical Data TD00808001E Pringle switch and replacement parts Effective November 2012 Table 7. Cross-Reference, Continued Description Feed Barriers 800A Top 1200–2000A Top 2500A Top 3000–4000A Top 800A Bottom 1200–2000A Bottom 2500A Bottom 3000A Bottom 4000A Bottom 800–2000A Top 2500A Top 3000–4000A Top 800–2000A Bottom 2500A Bottom 3000A Bottom 4000A Bottom SPVR—Single-Phase Voltage Relay Kit 480V (includes relay Bottom and top and support) 208V (includes relay Bottom and top and support) TB Pole Assembly 4000A, PMS (N/F) Bottom and top Transformers 480V Bottom and top 208V Bottom and top Handles 800A Bottom and top 800A, with provision for Bottom and top 6-foot 6-inch handle 800–2500A, ECOTE Bottom and top 800–2500A, ECOTE, with Top provision for 6-foot 6-inch handle 800–2500A, ECOTE, with Bottom provision for 6-foot 6-inch handle 1200–2500A Bottom and top 1200–2500A, with provision Top for 6-foot 6-inch handle 1200–2500A, with provision Bottom for 6-foot 6-inch handle 3000–4000A, ECOTE, with Top provision for 6-foot 6-inch handle 3000–4000A, ECOTE, with Bottom provision for 6-foot 6-inch handle 3000–4000A Bottom and top 3000–4000A Bottom and top 3000–4000A, with provision Top for 6-foot 6-inch handle 3000–4000A, with provision Bottom for 6-foot 6-inch handle Table 7. Cross-Reference, Continued Type Vista Style/Catalog Number QA QA QA QA QA QA QA QA QA CBC and special CBC and special CBC and special CBC and special CBC and special CBC and special CBC and special S5008 S5016 S5025 S5040 S5208 S5216 S5225 S5230 S5240 S5416 S5425 S5440 S5616 S5625 S5630 S5640 QA and CBC 7137R QA and CBC 7139R QA and CBC S10063 QA and CBC QA and CBC 4270 4272 QA QA 2450 2452 QA a QA a 2477 2521R QA a 2522R QA QA 2476 2442 QA 2443 QA a 2524R QA a 2525R QA QA a QA 2491 2492 2446 QA 2447 Description Handles, Continued 5000–6000A 800–2500A 800–2500A 800–2500A, ECOTE 800–2500A, ECOTE 800–2500A, with provision for 6-foot 6-inch handle 800–2500A, with provision for 6-foot 6-inch handle 800–2500A, ECOTE, with provision for 6-foot 6-inch handle 800–2500A, ECOTE, with provision for 6-foot 6-inch handle 3000–4000A 3000–4000A 3000–4000A, ECOTE 3000–4000A, ECOTE 3000–4000A, with provision for 6-foot 6-inch handle 3000–4000A, ECOTE, with provision for 6-foot 6-inch handle 3000–4000A, ECOTE, with provision for 6-foot 6-inch handle 3000–4000A, ECOTE, with provision for 6-foot 6-inch handle 800A 1200–2500A 3000–4000A Other Panel spacer, 1200–4000A Trim plate, 800–4000A Trim plate, 800–4000A Feed Type Vista Style/Catalog Number Bottom and top Top Bottom Top Bottom Top QA and CBC CBC CBC CBC a CBC a CBC 2515R 2463 2467 2464 2468 2444 Bottom CBC 2453 Top CBC a 2523 Bottom CBC a 2527 Top Bottom Top Bottom Top CBC CBC CBC a CBC a CBC 2498 2502R 2499 2503R 2448 Bottom CBC 2454 Top CBC a 2526 Bottom CBC a 2528R — — — PMS PMS PMS 2461 2485 2512R Bottom and top Bottom and top Bottom and top QA and CBC QA CBC 0911 3035 3036 a Special. a Special. eaton corporation www.eaton.com 7 Technical Data TD00808001E Effective November 2012 Pringle switch and replacement parts Eaton Corporation Electrical Sector 1111 Superior Avenue Cleveland, OH 44114 USA Eaton.com © 2012 Eaton Corporation All Rights Reserved Printed in USA Publication No. TD00808001E / Z12960 November 2012 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.