SIMPSON PRODUCTS
A ANGLES
Material: 12 gauge.
W1
W2
Length
Finish: galvanized
41⁄2"
6"
8"
4"
11"
41⁄2"
6"
8"
2"
35⁄8"
11⁄2"
11⁄2"
2"
21⁄2"
2"
Codes: BOCA, ICBO, SBCCI No.
NER-421 (except A44).
Code
A44
A66
A88
A24
A311
A44 Angle
A88 Angle
A34/A35 FRAMING ANCHORS
Code
The A35 anchors exclusive bending
slot allows instant, accurate field
bends for all two-way and threeway ties. Balanced, and completely
reversible design permits the A35
to secure a great variety of
connections.
18 gauge galvanized. Some
products available in stainless steel
or Z-Max. A34 uses 8-8d x 11⁄2"
nails. A35 and A35F use 128d x 11⁄2" nails. A35 uses 9-8d x 11⁄2"
nails for connection types A1, E,
C1.
A34
A35
A35F
A35F Framing Anchor
Codes: BOCA, ICBO, SBCCI No.
NER-413; Dade County, FL No. 960719.10; City of L.A. No. RR 25119.
A35F
AC/LPC POST CAPS
Twin design allows easy
installation.
Material: 18 gauge.
Finish: galvanized.
Installation: install in pairs.
LPC–21⁄2" beams may be used if
10d x 11⁄2" nails are substituted for
10d commons.
Codes: BOCA, ICBO, SBCCI Nos.
NER-421, NER-443, NER-469; Dade
County FL 93-1016.1, 92-0828.05;
City of L.A. RR 25076.
Width
Length
39⁄16"
—
51⁄2"
—
39⁄16"
61⁄2"
41⁄2"
81⁄2"
81⁄2"
51⁄2"
Code
AC4
ACE4
AC6
ACE6
LPC4
Use two
LPC6
post caps
AC
ACE
78
LCP
415-824-4300
SIMPSON PRODUCTS
ADJUSTABLE POST BASES
Fully adjustable post base offers
moisture protection, structural
values, ease of installation, and
finished hardware appearance.
Standoff plate provides flat end
bearing for post and keeps post end
11⁄8" above surface moisture.
Width
Length
39⁄16"
39⁄16"
51⁄2"
39⁄16"
51⁄2"
51⁄2"
Width
Height
Code
AB44
AB46
AB66
2” minimum
sidecover
Finish: 12 gauge adjustment and
stand-off plates. 16 gauge base
cover. Galvanized.
Installation: post nail holes are sized
for 10d commons. Rectangular
adjustment plate assumes 1⁄2"
diameter anchorage. The AB is
supplied as shown; position the
post, secure the easy-access nut,
then bend up the fourth side. For
non-bolt, non-adjustment
installations, 3⁄16" holes for optional
nail holddown or powder-actuated
fasteners in a concrete or wood
AB
base are in the base cover. A 2"
minimum side cover is required to obtain
the full load. Not recommended for nontop-supported installations such as
fences.
Codes: BOCA, ICBO, SBCCI NER-393;
City of L.A. RR 24818.
ALUMINUM POST STANDOFF
The APS stand-off height above
concrete or masonry floors or decks
reduces decay at post and column
ends.
31⁄4"
Code
1"
1"
51⁄8"
APS4
APS6
Material: cast aluminum.
Installation: attach to the post
before installation using four nail
holes. Embed a rod into concrete
and extend into wood member. For
nominal or rough sawn lumber.
APS4
BC POST CAPS/BASES
CAPS
W1
W2
L1
L2
H1
H2
39⁄16"
39⁄16"
27⁄8"
27⁄8"
Installed with 16d commons or
16d x 21⁄2" joist hanger nails. Not
recommended for non-topsupported installations such as
fences when used as a base.
39⁄16"
4"
51⁄2"
39⁄16"
4"
51⁄2"
47⁄8"
4"
43⁄8"
27⁄8"
4"
43⁄8"
3"
31⁄2"
3"
33⁄8"
3"
21⁄2"
3"
33⁄8"
BASES
W1
W2
L1
L2
H1
H2
Code
4
51⁄2"
51⁄2"
—
—
—
—
21⁄4"
Codes: BOCA, ICBO, SBCCI No.
NER-421; Dade County FL No. 920828.05; City of L.A. No. RR 25076.
—
—
—
—
31⁄4"
—
—
—
—
BC4O*
BC4OR
BC46O
BC6O
The BC series offers dual purpose
post cap/base for light cap or base
connections.
Material: 18 gauge galvanized.
39⁄16"#
BC4 Cap Bace
4"
33⁄8"
51⁄2"
*ALSO AVAILABLE IN 12 GAUGE
415-824-4300
79
3"
3"
3"
Code
BC4
BC46
BC4R
BC6
SIMPSON PRODUCTS
CB COLUMN BASES
W1
For columns that require high
structural values and rugged
performance.
Material: Simpson gray paint or
HDG.
3” minimum
sidecover
(2” for LCB)
W2
D
Code
39⁄16"
39⁄16"
8"
39⁄16"
51⁄2"
51⁄2"
51⁄2"
8"
8"
CB44
CB44R
CB46
CB66
CB66R
Installation: for full loads, minimum
side cover required is 3!. Install all
models with base plate flush with
concrete. Not recommended for
non-top-supported installations
such as fences.
Options: Rough and other sizes
available: specify W1 and W2
dimensions. Consult Simpson for
bolt sizes and allowable loads.
CB or LCB
Codes: BOCA, ICBO, SBCCI Nos.
NER-393 and NER-432; City of L.A.
Nos. RR 24818, RR 25074.
CBA COLUMN BASES
Code
Adjustable column base which
allows precise column placement
after the concrete cures. For new or
retrofitted nominal or rough 6x’s.
Bottom panel functions as a built-in
moisture barrier (partial barrier for
rough sizes.)
CBA66
Finish: galvanized.
Installation: install in pairs, using
two 16d nails for temporary
attachment while boring bolt holes.
Install all models with base plate
flush with concrete. Not
recommended for non-topsupported installations such as
fences. Options: rough and other
sizes available: specify W1 and W2
dimensions. Consult Simpson fo bolt
sizes and allowable loads.
CB44 configuration
(CB46, CB66 similar)
Codes: BOCA, ICBO, SBCCI
Nos. NER-393 and NER-432;
Dade County FL No. 93-1016.1;
City of L.A. Nos. RR 24818, RR
25074.
80
415-824-4300
SIMPSON PRODUCTS
CS COILED STRAPS
Total
Length
Continuous utility straps which can
be cut to length on the job site.
Packaged in lightweight (about 40
lbs.) cartons. Available in retail
packs of 25!; convenient for the doit-your-selfer or contractors who
require smaller strap lengths, and
packaged in portable 10" square
cartons.
150!
End
Length
Gauge
14!
16
Code
CS16
Finish: galvanized. Some products
available in Z-Max; contact factory.
Installation: wood shrinkage after
strap installation across horizontal
wood members may cause strap to
buckle outward.
Codes: BOCA, ICBO, SBCCI NER-413
and NER-499; Dade County FL
93-1016.1.
CS16
DECK-TIE CONNECTORS
Code
Material: DRT8 is 18 gauge, DPT5 and
7 are 14 gauge.
DPT7
DRT8
Finish: Z-max
Installation: DPT5 and 7: testing shows
similar strength and deflection limits
when compared with 4 x 4 posts
attached to 2 x 8 rim joists with two 1⁄2"
machine bolts placed 31⁄2" apart. Install
in pairs at a recommended minimum
center-center spacing of 5". Use two
3"8" through bolts and 5–10d x 11$2"
nails for DPT5 (5–10d commons for
DPT7) per tie.
DRT8 Deck Railing Tie: eliminates
nailing into the top of hand railing.
Attaches 2 x 4 and 2 x 6 hand railing to
posts. Use four #8 x 11⁄4" flathead
wood screws. Drive prongs into post,
then two screws into the post and two
screws into the railing.
415-824-4300
DRT8
81
SIMPSON PRODUCTS
DS DRYWALL STOP
Code
Eliminates costly blocking at top
plate, end walls, and corners. A
typical residence will use several
hundred of these inexpensive clips
with a substantial savings in
blocking and labor. The installation
prongs provide even more
labor savings.
DS1
Material: 20 gauge.
Finish: galvanized.
Installation: 16" on center or less,
using 8d commons.
Codes: BOCA, ICBO, SBCCI No.
NER-413.
DS
EPC POST CAPS
Size
W1
W2
L1
L2
L3
No
4x4
4x4
4x6
4x6
4x6
4x6
6x6
6x6
39⁄16"
39⁄16"
39⁄16"
39⁄16"
51⁄2"
51⁄2"
51⁄2"
51⁄2"
39⁄16"
39⁄16"
51⁄2"
51⁄2"
39⁄16"
39⁄16"
51⁄2"
51⁄2"
25⁄8"
25⁄8"
25⁄8"
25⁄8"
49⁄16"
49⁄16"
49⁄16"
49⁄16"
11"
11"
13"
13"
11"
11"
13"
13"
73⁄8"
73⁄8"
91⁄4"
91⁄4"
73⁄8"
73⁄8"
91⁄4"
91⁄4"
EPC44-16
EPC44
EPC46-16
EPC46
EPC64-16
EPC64
EPC66-16
EPC66
EPC
SSTB ANCHOR BOLTS
• Rolled threads for tensile
capacity.
• Stamped bolt head.
• Stamped embedment line.
Size
Code
16"
20"
24"
28"
SSTB16
SSTB20
SSTB24
SSTB28
Special Order
82
Allowable Tension Load (133) 1.2
Model7 Stemwall Dia Length Avg
Concrete Concrete Concrete
No.
Width
Ult f9 c=2500psi
BLock BLock End
5
5
6
13640
⁄8 17 ⁄8
4420
1850
SSTB16
4780
5⁄8 215⁄8 14745
6
4600
1850
SSTB20
4780
5⁄8 25 5⁄8 14745
6
5175
1850
SSTB24
4780
7⁄8 29 7⁄8 32700
8
10100
4815
SSTB28
6385
7⁄8 34 7⁄8 32700
8
10100
4815
SSTB34
6385
7⁄8 36 7⁄8 32700
8
10100
4815
SSTB36
6385
415-824-4300
SIMPSON PRODUCTS
FLOOR BEAM LEVELERS
Height
Jack piers and standard floor beam levelers offer unique leveling simplicity
during and after construction. JPs allow two simple methods of installation
for economy and design versatility. Both models are adjustable; see table.
Threaded
(Min-Max)
Rod Length
2”-4”
5”-7”
13”-18”
43⁄4"
Material: 12 gauge plates, 3⁄4" threaded rod, 3⁄4" steel pipe.
4"
8"
Code
JP44
J57
J1318
Finish: None. Connectors installed in damp areas, or corrosive environments
that are not exposed to rain or periodic washing, will deteriorate at a faster
rate. Corrosion-resistant finish and maintenance can improve the connectors
service life.
Installation: Use all specified fasteners; see general notes. Holes are
provided for installation with 16d commons. Do not use J/JPs for dynamic
jacking of structures, such as houses.
Codes: BOCA, ICBO, SBCCI No. NER-413. City of L. A. No. RR
JP
FOUNDATION ANCHORS
This series is for retrofit or new
construction. These products may
be used together as a system or in
individual applications, designed and
tested for earthquake and high wind
conditions.
installation.Material: 12 gauge.
FA anchors eliminate vertical drilling
by nailing into the top of the mudsill.
They facilitate installation when
vertical space is limited, and resist
forces between the foundation and
mudsill.
Codes: BOCA, ICBO, SBCCI Nos.
NER-469 (FA8, FJA); City of LA No.
RR25158.
Finish: galvanized.
Qty
1⁄2"
2
2
2
1⁄2"
Installation: select and install concrete
anchor bolts in accordance with the
manufacturer’s recommendations.
FJA foundation joist anchors nail or
bolt directly into floor joist, and
provides a direct connection
between the foundation and joist. It
provides uplift and lateral resistance.
FSA foundation stud anchors nail or
bolt to floor joists or nail to studs.
Plywood shearwall may require
nitching with stud-to-foundation
Diameter
1⁄2"
FJA
FA
FSA
415-824-4300
83
Code
FA8
FJA
FSA
SIMPSON PRODUCTS
H SEISMIC AND HURRICANE TIES
Gauge
The H connector series provides
wind and seismic ties for trusses
and rafters.
Code
18
H1
H2
H2.5
H3
H4
H5
H6
Finish: galvanized; also available in
stainless steel or Z-Max.
20
18
16
Installation: H1 can be installed
with flanges facing outwards.
When installed inside a wall, a
birdsmouth cut is required. H2.5,
H3, H4, and H5 ties are shipped in
equal quantities of separate rights
and lefts.
H2
Codes: BOCA, ICBO, SBCCI Nos.
NER-422, NER-393, NER-499; Dade
County, FL No. 96-0719.10; City of
L.A. No. RR 24818.
H3
H2.5
H6
H1
H5
H4
HH HEADER HANGERS
For fast, accurate installation of door
and window headers and other cross
member details. HH header hangers
speed up the job, strengthen the
frame, and eliminate the need for
trimmers.
Width
Height
39⁄16"
51⁄2"
27⁄8"
51⁄4"
Code
HH4
HH6
Material: 16 gauge.
Finish: galvanized.
Codes: BOCA, ICBO SBCCI No. NER413; Dade County, FL No. 93-0828.4;
City of L.A. No. RR 25119.
HH
84
415-824-4300
SIMPSON PRODUCTS
HDA HOLDOWNS
Base Body
Holdowns are used to transfer tension loads between floors, to tie
pulins to masonry or concrete, etc. Use for overturn requirements
and other applications to transfer tension loads. All HDAs are selfjigging, ensuring code-required minimum 7! bolt diameter spacing
from the end of the wood member.
Gauge Gauge HB
7"
3"
3⁄8
"
12" 41⁄2"
10" 51⁄4"
7" 63⁄16"
SB
W
21⁄2"
3"
31⁄2"
HD6a, HD8A, HD10A’s seat design allows greater installation
adjustability. An overall width of 31⁄4" for the HD6A, HD8A and
HD10A provides for an easy fit in a standard 4x wall.
H
B
SO
21⁄2"
8"
25⁄8"
33⁄16" 93⁄8"
31⁄2"
31⁄8" 111⁄16" 37⁄16"
143⁄8"
177⁄8"
CL
" 11⁄2"
1⁄2"
21⁄16"
9⁄16" 21⁄16"
1⁄4
Code
HD2A
HD5A
HD6A
HD8A
HD10A
Special Features: single piece non-welded design results in higher
capacity. Load transfer plate eliminates the need for a seat washer.
Fewer inspection problems.
Finish: galvanized. HD8A may be ordered HDG; check with the
factory.
Installation: for an improved connection, use a steel nylon locking
nut or a thread adhesive on the anchor bolt. Bolt holes shall be a
minimum of 1⁄32" to a maximum of 1⁄16" larger than the bolt
diameter (per 1991 NDS, section 8.1.2.1.)
Standard washers are required on stud bolt nuts against the wood.
The Load Transfer Plate is an integral part of the HDA Hold down
and no washer is required.
Locate on wood member to maintain a minimum distance of seven
bolt diameters from the end of the member to the centerline of the
first bolt hole (HDAs are self-jigging; minimum required distance is
automatically maintained when end of wood member is flush with
the bottom of the holdown.)
To tie double 2x members together, the designer must determine
the fasteners required to bind members to act as one unit without
splitting.
For holdowns installed on the mudsill, anchor bolt nuts should be
finger-tight plus 1⁄3 to 1⁄2 turn with a wrench, with consideration
given to possible future wood shrinkage. Care should be taken to
not over-torque the nut, which may lead to premature anchor bolt
failure.
HD5A
Stud bolts should be snugly tightened (per 1991 NDS, section
8.1.2.4.)
Codes: BOCA, ICBO, SBCCI Nos. NER-393, NER-469; City of L.A.
Nos. RR 24818 and RR 25158.
HL HEAVY ANGLES AND GUSSETS
GA
Versatile angle gussets and heavy
angles promote standardization and
construction economy, and are
compatible with Strong-Tie
structural hardware.
7
7
7
Finish: Simpson gray paint.
L
D1
D2
D3
D4
Code
31⁄4"
21⁄2"
11⁄4"
31⁄4"
53⁄4"
5"
5"
11⁄4"
11⁄4"
—
21⁄2"
21⁄2"
2"
2"
2"
—
—
21⁄2"
HL33
HL35G*
HL55
HL35G* IN STOCK
Options: gussets may be added to
HL models when L%5" (specify G
after model number, as in HL46G.)
415-824-4300
W1 & W2
85
SIMPSON PRODUCTS
HU FACE MOUNT HANGERS
Joist Size
Most models have triangle and
round holes, which give high loads
when filled with common nails.
These heavy-duty connectors are
designed for schools and other
structures requiring additional
strength, longevity and safety
factors.
3!x12!
2x4
4x 6
4x 8
4 x 10
4 x 12
6x6
6x8
6 x 10
6 x 12
HU min. nailing
fill round holes.
HU max. nailing
fill round and
triangle holes.
Can be installed filling round holes
only, or filling round and triangle
holes for maximum values.
Gauge
W
H
B
14
29⁄16"
39⁄16"
105⁄8"
27⁄8"
53⁄16"
613⁄16"
85⁄8"
105⁄16"
43⁄16"
513⁄16"
75⁄8"
93⁄8"
21⁄2"
51⁄2"
Code
HU312
HU44
HU46
HU48
HU410
HU412
HU66
HU68
HU610
HU612
Codes: BOCA, ICBO, ICBO No.
5117; Dade County, FL No. 960719.09; City of L.A. Nos. RR
24947, RR 24818.
HU68
HUC FACE MOUNT HANGERS
Concealed flange.
Joist Size
4x 6
4x 8
4 x 10
4 x 12
6x6
Gauge
W
H
B
14
29⁄16"
105⁄8"
21⁄2"
Code
39⁄16"
51⁄2"
613⁄16"
85⁄8"
105⁄16"
43⁄16"
HUC46
HUC48
HUC410
HUC412
HUC66
Gauge
W
H
B
Code
14
29⁄16"
105⁄8"
613⁄16"
85⁄8"
105⁄16"
21⁄2"
HUC412
Concealed
Flanges
HUS FACE MOUNT HANGERS
Joist Size
Provides intermediate load-carrying
capacity. Available with the head
flanges turned.
4x 6
4x 8
4 x 10
4 x 12
Codes: BOCA, ICBO, SBCCI Nos.
NER-209, NER-413, NER-421, NEW499; Dade County, FL No. 930828.8, 93-0824.07; City of L.A.
Nos. RR 24949, RR 25076.
HUS46
HUS48
HUS410
HUS412
HUS412
86
415-824-4300
SIMPSON PRODUCTS
IS INSULATION SUPPORTS
Size
Easy one-hand installation to hold
insulation in place. Mitered edges
ensure a tight fit when installed
between joists.
Code
151⁄2"
231⁄2"
IS16
IS24
Installation: Install insulation
supports between joists. IS16
(151⁄2" long) for 16" o.c. spacing;
IS24 (231⁄2" long) for 24" o.c.
spacing. Follow the insulation
manufacturer’s installation
recommendations.
LU FACE MOUNT HANGERS
Joist Size
Value engineered for strength and
economy! Just a tap of the hammer
at each speed prong secures the LU
for easy nailing. Precision formed
— engineered for installation ease
and design value.
2x4
2 x 6, 8
2 x 8, 10
2x10, 12, 14
Gauge
W
H
B
20
19⁄16"
31⁄8"
43⁄4"
63⁄8"
713⁄16"
11⁄2"
Code
LU24
LU26
LU28
LU210
Codes: BOCA, ICBO, SBCCI No.
NER-393.; Dade County, FL No. 960719.09; City of L.A. Nos. RR
24947, RR 24818.
LSSU LIGHT SLOPED/SKEWED U HANGERS
Joist
Size
All models are skew- and slopeadjustable on the job site! Attach
joists or rafters to headers, sloped
up or down, and skewed left or
right, up to 45º.
2x8
2 x 10 & up
3 x 10 & up
W
H
19⁄16"
71⁄8"
19⁄16"
29⁄16"
81⁄2"
81⁄2"
Material: 18 gauge.
Finish: galvanized.
Installation: attach the sloped joist
at both ends so that the horizontal
force developed by the slope is fully
supported by the supporting
members.
Codes: BOCA, ICBO, SBCCI Nos.
NER-209, NER-421, NER-432. City
of L.A. Nos. RR24949, 25074 and
25076.
LSSU
415-824-4300
LSSU28
87
Code
LSSU28
LSSU210
LSSU310
SIMPSON PRODUCTS
LUS FACE MOUNT HANGERS
Joist Size
A light duty joist hanger with the
lowest installed cost. Speed prongs
secure the LUS for easy nailing.
Gauge
2’x 4’
18
2’x 6’,8’
2’x 8”,10’
2’x 10’, 12’, 14’
4’x 4’
4’x 6’, 8’
4’x 8’, 10’
4’x 10’, 12’, 14’
4’x 12’ , 14’
DBL 2’x 4’
DBL 2’x 6’, 8’
DBL 2’x 8’, 10’
DBL 2’x 10’, 12’, 14’
MONKEY PAW™ ANCHOR
BOLT HOLDERS
2’x 4’
H
B
Code
19⁄16”
31⁄8”
43⁄4”
65⁄8”
713⁄16”
3”
43⁄4”
63⁄4”
83⁄4”
103⁄4”
31⁄8”
47⁄8”
7”
9”
13⁄4”
LUS24
LUS26
LUS28
LUS210
LUS44
LUS46
LUS48
LUS410
LUS414
LUS24-2
LUS26-2
LUS28-2
LUS210-2
39⁄16”
31⁄8”
Bolt
Size
Offers significant savings over
plywood or 2x wood holders. Use
the MKP5/8 to install the SSTB16,
20, and 24. May be used several
times. Stabilizes bolt by providing
three-point support against lateral
concrete pressure. Alignment
arrows (left or right) match the
SSTB bolt head arrow. Stamped for
2x4 ro 2x6 mudsill placement. No
nut required to hold bolt in place.
When removed, the MKP cleans the
bolt thread of concrete.
W
Dia
5⁄8"
2”
Finish
galvanized
Code
MKP5⁄8
MKP 5/8” with SSTB16
NAILS
Description
Strong-Tie nails and structural
fasteners have been developed as
the optimum fasteners for
connector products. Special lengths
afford economy of purchase and
installation, and depth compatibility
with framing members. Nail
specifications include head size,
thickness, steel and shank design,
and point configuration to ensure
conformity to published values.
(8d) 101⁄4GA x 11⁄2" Smooth Shank
(10d) 9GA x 11⁄2" Smooth Shank
(16d) 8GA x 21⁄2" Smooth Shank
(20d) 0.192 x 21⁄8" Annular Ring
(20d) 0.192 x 13⁄4" Annular Ring
0.250 x 21⁄2" Annular Ring
88
Metric
Equivalent
Finish
Code
3.3MM x 38.1MM
3.8MM x 38.1MM
4.1MM x 63.5MM
4.9MM x 54.0MM
4.9MM x 44.5MM
6.4MM x 63.5MM
HDG
HDG
Bright
Bright
Bright
Bright
N8
N10
N16
N20AN
N20A
N54A
415-824-4300
SIMPSON PRODUCTS
NAIL STOPPERS
Help prevent nails from piercing
water pipes and electrical lines.
Installed over utilities that prevent
framing members the NS provides a
warning and allows repositioning of
the nail. 16 gauge steel conforms to
the National Electric Code. Install
with 8d commons or prongs.
Size
3"
Material
Finish
16GA
galvanized
Code
NS1
NS1 or NS2
PB POST BASES
Locking prongs eliminate bolts or
inserts in concrete. One-piece
design assures maximum strength.
Finish: 12 gauge galvanized.
Installation: Holes are provided for
installation with either 16d
commons or 1⁄2" bolts. A 2"
minimum sidecover is required to
obtain the full load. Not
recommended for non-topsupported installations such as
fences.
Width
Length
39⁄16"
31⁄4"
4"
51⁄2"
51⁄2"
31⁄4"
31⁄4"
53⁄8"
Code
PB44
PB44R
PB46
PB66
Codes: BOCA, ICBO, SBCCI NER443. Dade Co., FL No. 92-0828.05;
City of L.A. RR 25149.
2” minimum sidecover
PB44
PC POST CAPS
PC
Size
W1
W2
L1
L2
L3
No
4x4
4x4
4x6
4x6
4x6
4x6
6x6
6x6
39⁄16"
39⁄16"
39⁄16"
39⁄16"
51⁄2"
51⁄2"
51⁄2"
51⁄2"
39⁄16"
39⁄16"
51⁄2"
51⁄2"
39⁄16"
39⁄16"
51⁄2"
51⁄2"
25⁄8"
25⁄8"
25⁄8"
25⁄8"
49⁄16"
49⁄16"
49⁄16"
49⁄16"
11"
11"
13"
13"
11"
11"
13"
13"
73⁄8"
73⁄8"
91⁄4"
91⁄4"
73⁄8"
73⁄8"
91⁄4"
91⁄4"
PC44-16
PC44
PC46-16
PC46
PC64-16
PC64
PC66-16
PC66
PLATE STRAPS
Material
16ga
RPS
415-824-4300
89
L
H
11⁄2"
11⁄2"
11⁄2"
185⁄16"
225⁄16"
285⁄16"
Code
RPS18
RPS22
RPS28
SIMPSON PRODUCTS
PLYWOOD SHEATHING CLIPS
Size
Material
Finish
1⁄2"
20 gauge
galvanized
Code
PSC04
PSC05
PSC06
5⁄8"
3⁄4"
Provides
1/8” gap
PSCL
PREDEFLECTED HOLDOWNS
The Predeflected Holdown (PHD) is
a revolutionary development in
holdown connections. This
connector is a predeflected during
manufacturing, to virtually eliminate
deflection from material stretch.
Gauge
W
H
B
CL
14
3"
95⁄16"
119⁄16"
1313⁄16"
173⁄16"
27⁄8"
27⁄8"
13⁄8"
13⁄8"
12
10
Code
PHD2
PHD5
PHD6
PHD8
Wood screws reduce slip due to
overdrilled bolt holes. Smaller
centerline reduces eccentricity in
the stud. No stud bolts to
countersink. the slot in the seat
provides anchor bolt adjustment.
Connectors 3" width fits easily on a
4x wall.
Material: see table.
Finish: galvanized.
Installation: place over the anchor
bolt. Install Simpson’s SDS1⁄4"x 3"
wood screws (sold separately.) For
an improved connection, use a steel
nylon locking nut or a thread
adhesive on the anchor bolt. To tie
double 2x members together, the
designer must determine the
fasteners required to bind members
to act as one unit without splitting
the wood.
PHD
Codes: submitted to ICBO and City
of L.A. in 10/96.
REINFORCING AND SKEWABLE ANGLES
L – Curved metal speed prong reduces labor and
overall construction cost. Staggered nail pattern
reduces the possibility for splitting and allows
installation on both sides of a member.
LS – Field-adjustable angles attach members
intersecting at angles. Bend one time only. Joist
must be constrained against rotation
(for example, with solid blocking) when using a
single LS per connection.
Codes: BOCA, ICBO, SBCCI Nos. NER-413, NER443; City of L.A. Nos. RR 25119, 25149
Size
Material
3"
5"
7"
9"
33⁄8"
47⁄8"
63⁄8"
16GA
18GA
Code
L30
L50
L70
L90
LS30
LS50
LS70
L70
90
415-824-4300
SIMPSON PRODUCTS
ROTATED COLUMN END CAPS
Width1
The industry standard column cap.
Precision factory gang-punched
holes speed installation.
35⁄8"
35⁄8"
51⁄4"
51⁄2"
Material: CC44, CC46, CC64, CC66
are 7 gauge; all others are 3 gauge.
Width2
35⁄8"
51⁄2"
51⁄2"
51⁄2"
Finish: Simpson gray paint; may be
ordered HDG.
Options: straps may be rotated 90º
where W1% W2. For special,
custom, or rough cut lumber sizes,
provide dimensions. An optional W2
dimension may be specified with
any column size given (note that the
W2 dimension on straps rotated 90º
is limited by the W1 dimension.)
Column caps with W1, L, H1, and
hole schedules different from the
shown dimensions may be special
Width1
CC66
ordered. Provide a drawing to
ensure accuracy. For end
conditions, specify ECC.
L dimensions will vary from 51⁄2
to 101⁄2. Uplift loads do not
apply to the ECC. ECC9 and 10
use four beam bolts.
SIMPSON STRONG-DRIVE®
4CUT™ INTERIOR AND
EXTERIOR SCREW
The Simpson Strong-Drive® screw
(SDS) is a 1⁄4" diameter structural
wood screw ideal for various
connector installations as well as
wood-to-wood applications. It
installs with no predrilling and has
been extensively tested in various
applications. For 2007 the SDS is new
and improved with a patented new
easy driving tip and a corrosion
resistant coating.
35⁄8"
35⁄8"
51⁄4"
51⁄2"
51⁄2"
91
35⁄8"
51⁄2"
51⁄2"
35⁄8"
51⁄2"
CC
H1
Code
7"
11"
13"
11"
4"
61⁄2"
8"
61⁄2"
CC44
CC46
8CC51⁄4-6
CC66
ECC
H1
Code
51⁄2"
81⁄2"
91⁄2"
71⁄2"
71⁄2"
4"
61⁄2"
8"
61⁄2"
61⁄2"
ECC44
ECC46
ECC51⁄4-6
ECC64
ECC66
Length
Size
Qty
Finish
11⁄2"
2"
21⁄2"
3"
31⁄2"
41⁄2"
6"
25/BOX
25/BOX
25/BOX
25/BOX
10/BOX
10/BOX
10/BOX
Double Barrier
Size
Qty
Finish
300/CASE
250/CASE
200/CASE
150/CASE
125/CASE
100/CASE
100/CASE
Double Barrier
11⁄2"
2"
• The patented 4CUT™ tip has a square
21⁄2"
core and serrated threads to reduce
• A new Double-Barrier Coating 3"
installation torque and make driving
31⁄2"
finish provides corrosion
easier with no predrilling and minimal
resistance superior to hot-dip 41⁄2"
wood splitting
galvanization. Now one screw 6"
• 3⁄8" hex washer head is stamped with
can handle interior, exterior
the No-Equal sign and fastener length
and certain pressure-treated
for easy indentification after installation.
wood applications
415-824-4300
Width2
Length
Code
9DBB14
9DBB20
9DBB24
9DBB30
9DBB34
9DBB44
9DBB60
Code
9DBC14
9DBC20
9DBC24
9DBC30
9DBC34
9DBC44
9DBC60
SIMPSON PRODUCTS
STANDOFF POST BASES
Provides tested capacity. Features
1" stand-off height above concrete
floors, code-required when
supporting permanent structures
that are exposed to the weather or
water splash, or in basements.
Reduces the potential for decay at
post and column ends.
ABE and ABU’s base design
includes anchor bolt adjustment
slot. Four-sided stand-off plate
increases download support and
provides attractive appearance.
2” minimum
sidecover
W1
W2
39⁄16"
31⁄2"
39⁄16"
51⁄2"
39⁄16"
51⁄2"
39⁄16"
31⁄2"
51⁄8"
31⁄2"
57⁄16"
31⁄2"
D
L
—
—
5"
71⁄8"
67⁄8"
31⁄2"
31⁄2"
3"
13⁄4"
21⁄4"
3"
21⁄4"
HB
Code
13⁄4"
5⁄8"
45⁄16"
41⁄2"
37⁄16"
ABE44
ABU44
ABU66
CBS44
CBS66
PBS44
ABE44
CBS and PBS embed into wet
concrete up to the bottom of the 1"
standoff base plate. A 3" minimum
side cover is required to obtain the
full load for CBS; 2" for PBS. Holes
in the bottom of the PBS and CBS
straps allow for free concrete flow.
1” standoff
satisfies code
requirements
3” minimum
sidecover
2” minimum
sidecover
6 gauge, galvanized. Some products
available in Z-Max. Not
recommended for non-topsupported installations such as
fences. For pre-poured anchors,
embed 4& into concrete. For epoxy
or wedge anchors, select and install
according to anchor manufacturer’s
recommendations; anchor diameter
shown in table. Install requires
washer.
CBS44
PBS44
Codes: BOCA, ICBO, SBCCI Nos.
NER-422, NER-432, NER-469;
City of L.A. Nos. RR 25064, 25074,
25158; Dade County FL No. 93-1016.1
STRAP TIES
Piling straps connect wood pilings
to floor girders in elevated
structures. Hot-dipped galvanized
for greater corrosion resistance.
Install where plates or soles are
cut, at wall intersections, and as
ridge ties.
Codes: BOCA, ICBO, SBCCI No.s
NER-413 and NER-443; Dade
County, FL No. 93-0828.7. City of
L.A. Nos. RR 25119, 25149.
Width
Length
Material
Code
21⁄16"
21⁄16"
21⁄16"
21⁄16"
11⁄2"
27"
37"
48"
60"
185⁄16"
225⁄16"
285⁄16"
95⁄16"
1213⁄16"
165⁄16"
12GA
MST27
MST37
MST48
MST60
RPS18
RPS22
RPS28
ST292
ST2122
ST2115
ST6215
ST6224
ST22
ST6236
21⁄16"
21⁄16"
3⁄4"
21⁄16"
21⁄16"
11⁄4"
21⁄16"
MSTI
92
10GA
16GA
20GA
16GA
235⁄16"
215⁄8"
3313⁄16"
14GA
415-824-4300
SIMPSON PRODUCTS
SUR/SUL SKEWED 45º HANGERS
Joist Size
Standardized and code-listed 45º
skewed hangers. Angled slots
direct nails to allow speedy and
proper installation of the nails.
W
H
B
A1
A2
Code
2 x 6,8
2 x 10,16
19⁄16"
19⁄16"
5"
81⁄8"
2"
2"
1"
1"
13⁄8"
13⁄8"
SUR/L26
SUR/L210
Material
L
H
B
Qty
Dia
Code
7GA ptd
7GA ptd
7GA ptd
7GA ptd
7GA ptd
7GA ptd
7GA ptd
7GA ptd
6"
8"
12"
16"
6"
12"
12"
16"
6"
8"
12"
16"
5"
8"
12"
16"
11⁄2"
2"
2"
21⁄2"
11⁄2"
2"
2"
21⁄2"
3
3
3
4
3
3
3
6
3⁄8
66L
88L
1212L
1616HL
66T
128T
1212T
1616HT
Material: 16 gauge.
Finish: galvanized.
Installation: these hangers will
normally accommodate a 40º to 50º
skew. SUR=skewed right;
SUL=skewed left. The joist end
may be square cut or bevel cut.
Codes: ICBO No. 5117; City of L.A.
RR 24947; Dade County, FL No. 930824.07.
SUL
T AND L STRAP TIES
66T
66L
1⁄2
1⁄2
5⁄8
3⁄8
1⁄2
1⁄2
5⁄8
TS TWIST STRAPS
Length
Twist straps provide a tension
connection between two wood
members. An equal number of right
and left hand units are supplied in
each carton unless ordered
otherwise.
9"
115⁄8"
173⁄4"
Material: 16 gauge.
Finish: galvanized. Some products
available in stainless steel and ZMax.
Installation: use all specified
fasteners.
415-824-4300
TS
93
Total Fasteners
8-16d
10-16d
14-16d
Code
TS9
TS12
TS18
SIMPSON PRODUCTS
TENSION TIES
Tension ties are ideal for retrofit or
new construction and provide postpour, concrete-to-wood
connections. MTT28B amy be
ordered HDG; check with the
factory.
Strap
Plate
W
L
CL
Code
12GA
7GA
21⁄16"
27"
15⁄8"
MTT28B
Codes: BOCA, ICBO, SBCCI No.
NER-393; City of L.A. No. RR24818.
MTT28B
TIE PLATES
Width
TPs are nail-on tie plates. TPAs are
flanged for added support.
Length
No of Nail Holes
11"
9"
11"
7"
50
54
66
60
31⁄8"
41⁄8"
41⁄8"
53⁄4"
Material: 20 gauge.
FInish: galvanized.
Installation: holes are sized for 8d
common or 8d x 11⁄2" nails.
Code
TP311
TP49
TP411
TP57
TP
U FACE MOUNT HANGERS
Joist Size
The standard U hanger provides
flexibility of joist to header
installation. Some models have
speed prongs for fast installation.
Versatile fastener selection with
tested allowable loads.
Gauge
2x4
16
2 x 6,8
2 x 10, 12, 14
2 x 14, 16
DBL 2 x 4
DBL 2 x 6, 8
DBL 2 x 10
Rough 2 x 4
Rough 2 x 6, 8
Rough 2 x 10,12,14
W
H
B
19⁄16"
31⁄8"
11⁄2"
43⁄4"
713⁄16"
10"
3"
5"
81⁄2"
35⁄8"
55⁄8"
91⁄8"
2"
31⁄8"
2"
2"
2"
Code
U24
U26
U210
U214
U24-2
U26-2
U210-2
U24R
U26R
U210R
U210
94
415-824-4300
SIMPSON PRODUCTS
UNIVERSAL FOUNDATION PLATE
Code
The UFP10 Retrofit Foundation Plate
cuts installation time in half!
Designed to connect when the
mudsill is offset from the foundation
up to 21⁄2" or extended beyond the
foundation up to 1⁄2". UFP may be
used in place of FA, HFA and FAP.
UFP10
Material: 14 gauge.
Finish: galvanized.
Codes: City of L.A. RR 25281.
UFP10 on a
straight foundation with
offset mudsill
WALL BRACING
Length
Designed to fulfill the same code
bracing requirements as 1 x 4 let-in
bracing, but less expensive and
faster to install. Resists racking
during construction. Not designed
to replace shearwall load-carrying
components.
53⁄8"
9!
11! 43⁄8"
11! 43⁄4"
11! 43⁄8"
Material: 16 gauge.
Finish: galvanized.
Installation:
WB and WBC: install in “X” pairs or
in opposing “V” fashion. Use with
16" or 24" o.c. studs.
CWB: use with 16" o.c. studs.
Established run-line using the
bracing as a straight edge. Single
cut a saw kerf 1" deep along the
run line. If the wall is pre-framed on
the floor, place the part into the
saw kerf, and put one nail into the
top plate, bottom plate and studs
according to the nailing schedule.
WB
Codes: BOCA, ICBO, SBCCI Nos.
NER-413, NER-432, NER-443, NER422; Dade County, FL. 93-0824.07:
City of L.A. RR 25074, RR 25119,
RR 25149.
415-824-4300
95
Angle
Wall Size
Code
8!
60º
45º
WB106
WB126
WB126C
CWB126
SIMPSON PRODUCTS
WT WEDGE FORM TIES
Especially designed for low
foundation wall applications. 5⁄8"
wide formed “V” design for rigidity
allows accurate form spacing and
support.
Wall Thickness
Code
6"
8"
10"
12"
Material: 18 gauge.
Finish: galvanized.
WT6
WT8
WT10
WT12
WT8
Installation: not recommended for
wall pours greater than 4! high. Fits
1" or 2" nominal form lumber. Wall
thickness from 6" to 12".
WI WEDGE
Material: 18 gauge.
Gauge
Finish: galvanized.
18
Code
W1
Installation: use two 31⁄2" long
wedges for each tie.
W1
COLUMN CAP
W1
W2
L
H
Qty
3/”
51/2”
3/”
51/2”
7”
11”
4”
61/2”
EA
5 8
5 8
EA
Code
CC44HDG
CC66HDG
COLUMN CAP
W1
W2
L1
L2
H
Qty
Code
3/”
51/2”
3/”
51/2”
5/”
71/2”
6/”
91/2”
4”
61/2”
EA
ECC44HDG
ECC66HDG
5 8
96
5 8
1 2
1 2
EA
415-824-4300
SIMPSON PRODUCTS
STAND OFF POST BASE
W
39/16”
51/2”
L
H
Qty
39/16”
59/16”
21/4”
3”
EA
EA
Code
AB44Z
AB66Z
REINFORCING ANGLE
Qty
L50
EA
EA
Code
L50Z
L70Z
L70
REGULAR POST BASES
W
39/16”
51/2”
L
Qty
31/4”
51/4”
EA
EA
Code
PB44Z
PB66Z
2” MINIMUM SIDECOVER
POST CAP
W1
W2
L1
L2
L3
Qty
Code
3/ ”
51/2”
3/ ”
51/2”
2/”
49/16”
11”
13”
7/ ”
91/4”
EA
PC4416Z
PC66Z
9 16
415-824-4300
97
9 16
5 8
5 16
EA
SIMPSON PRODUCTS
HOLDDOWNS
COLUMN BASES
HB4
SB
W
H
B
49/16”
63/16”
21/2”
31/2”
23/4”
31/4”
8”
149/16”
29/16”
37/16”
1 5/16" for 5/8" bolts
1 1/2" for 3/4" bolts
CL
Qty
Code
/”
/ ”
17/16”
21/16”
EA
HD2AHDG
HD8AHDG
3 8
9 16
EA
W1
W2
D
Qty
Code
3/ ”
51/2”
3/ ”
51/2”
8”
8”
EA
CB44HDG
CB66HDG
9 16
DOUBLE SHEAR JOIST
HANGERS
SO
W
1/ ”
19/16”
31/8”
19/16”
31/8”
19/16”
31/8”
39/16”
39/16”
39/16”
9 16
9 16
EA
H
B
Qty
Code
3/”
43/4”
47/8”
65/8”
7”
713/16”
9”
3”
43/4”
63/4”
1/”
13/4”
2”
13/4”
2”
13/4”
2”
2”
2”
2”
EA
LUS24Z
LUS26Z
LUS26-2Z
LUS28Z
LUS28-2Z
LUS210Z
LUS210-2Z
LUS44Z
LUS46Z
LUS48Z
H
Qty
11/2”
EA
1 8
3 4
EA
EA
EA
EA
EA
EA
EA
EA
EA
STAIRCASE ANGLES
W
101/4”
Code
TA10Z
TA9Z
TA10
98
415-824-4300
Download