SIMPSON PRODUCTS A ANGLES Material: 12 gauge. W1 W2 Length Finish: galvanized 41⁄2" 6" 8" 4" 11" 41⁄2" 6" 8" 2" 35⁄8" 11⁄2" 11⁄2" 2" 21⁄2" 2" Codes: BOCA, ICBO, SBCCI No. NER-421 (except A44). Code A44 A66 A88 A24 A311 A44 Angle A88 Angle A34/A35 FRAMING ANCHORS Code The A35 anchors exclusive bending slot allows instant, accurate field bends for all two-way and threeway ties. Balanced, and completely reversible design permits the A35 to secure a great variety of connections. 18 gauge galvanized. Some products available in stainless steel or Z-Max. A34 uses 8-8d x 11⁄2" nails. A35 and A35F use 128d x 11⁄2" nails. A35 uses 9-8d x 11⁄2" nails for connection types A1, E, C1. A34 A35 A35F A35F Framing Anchor Codes: BOCA, ICBO, SBCCI No. NER-413; Dade County, FL No. 960719.10; City of L.A. No. RR 25119. A35F AC/LPC POST CAPS Twin design allows easy installation. Material: 18 gauge. Finish: galvanized. Installation: install in pairs. LPC–21⁄2" beams may be used if 10d x 11⁄2" nails are substituted for 10d commons. Codes: BOCA, ICBO, SBCCI Nos. NER-421, NER-443, NER-469; Dade County FL 93-1016.1, 92-0828.05; City of L.A. RR 25076. Width Length 39⁄16" — 51⁄2" — 39⁄16" 61⁄2" 41⁄2" 81⁄2" 81⁄2" 51⁄2" Code AC4 ACE4 AC6 ACE6 LPC4 Use two LPC6 post caps AC ACE 78 LCP 415-824-4300 SIMPSON PRODUCTS ADJUSTABLE POST BASES Fully adjustable post base offers moisture protection, structural values, ease of installation, and finished hardware appearance. Standoff plate provides flat end bearing for post and keeps post end 11⁄8" above surface moisture. Width Length 39⁄16" 39⁄16" 51⁄2" 39⁄16" 51⁄2" 51⁄2" Width Height Code AB44 AB46 AB66 2” minimum sidecover Finish: 12 gauge adjustment and stand-off plates. 16 gauge base cover. Galvanized. Installation: post nail holes are sized for 10d commons. Rectangular adjustment plate assumes 1⁄2" diameter anchorage. The AB is supplied as shown; position the post, secure the easy-access nut, then bend up the fourth side. For non-bolt, non-adjustment installations, 3⁄16" holes for optional nail holddown or powder-actuated fasteners in a concrete or wood AB base are in the base cover. A 2" minimum side cover is required to obtain the full load. Not recommended for nontop-supported installations such as fences. Codes: BOCA, ICBO, SBCCI NER-393; City of L.A. RR 24818. ALUMINUM POST STANDOFF The APS stand-off height above concrete or masonry floors or decks reduces decay at post and column ends. 31⁄4" Code 1" 1" 51⁄8" APS4 APS6 Material: cast aluminum. Installation: attach to the post before installation using four nail holes. Embed a rod into concrete and extend into wood member. For nominal or rough sawn lumber. APS4 BC POST CAPS/BASES CAPS W1 W2 L1 L2 H1 H2 39⁄16" 39⁄16" 27⁄8" 27⁄8" Installed with 16d commons or 16d x 21⁄2" joist hanger nails. Not recommended for non-topsupported installations such as fences when used as a base. 39⁄16" 4" 51⁄2" 39⁄16" 4" 51⁄2" 47⁄8" 4" 43⁄8" 27⁄8" 4" 43⁄8" 3" 31⁄2" 3" 33⁄8" 3" 21⁄2" 3" 33⁄8" BASES W1 W2 L1 L2 H1 H2 Code 4 51⁄2" 51⁄2" — — — — 21⁄4" Codes: BOCA, ICBO, SBCCI No. NER-421; Dade County FL No. 920828.05; City of L.A. No. RR 25076. — — — — 31⁄4" — — — — BC4O* BC4OR BC46O BC6O The BC series offers dual purpose post cap/base for light cap or base connections. Material: 18 gauge galvanized. 39⁄16"# BC4 Cap Bace 4" 33⁄8" 51⁄2" *ALSO AVAILABLE IN 12 GAUGE 415-824-4300 79 3" 3" 3" Code BC4 BC46 BC4R BC6 SIMPSON PRODUCTS CB COLUMN BASES W1 For columns that require high structural values and rugged performance. Material: Simpson gray paint or HDG. 3” minimum sidecover (2” for LCB) W2 D Code 39⁄16" 39⁄16" 8" 39⁄16" 51⁄2" 51⁄2" 51⁄2" 8" 8" CB44 CB44R CB46 CB66 CB66R Installation: for full loads, minimum side cover required is 3!. Install all models with base plate flush with concrete. Not recommended for non-top-supported installations such as fences. Options: Rough and other sizes available: specify W1 and W2 dimensions. Consult Simpson for bolt sizes and allowable loads. CB or LCB Codes: BOCA, ICBO, SBCCI Nos. NER-393 and NER-432; City of L.A. Nos. RR 24818, RR 25074. CBA COLUMN BASES Code Adjustable column base which allows precise column placement after the concrete cures. For new or retrofitted nominal or rough 6x’s. Bottom panel functions as a built-in moisture barrier (partial barrier for rough sizes.) CBA66 Finish: galvanized. Installation: install in pairs, using two 16d nails for temporary attachment while boring bolt holes. Install all models with base plate flush with concrete. Not recommended for non-topsupported installations such as fences. Options: rough and other sizes available: specify W1 and W2 dimensions. Consult Simpson fo bolt sizes and allowable loads. CB44 configuration (CB46, CB66 similar) Codes: BOCA, ICBO, SBCCI Nos. NER-393 and NER-432; Dade County FL No. 93-1016.1; City of L.A. Nos. RR 24818, RR 25074. 80 415-824-4300 SIMPSON PRODUCTS CS COILED STRAPS Total Length Continuous utility straps which can be cut to length on the job site. Packaged in lightweight (about 40 lbs.) cartons. Available in retail packs of 25!; convenient for the doit-your-selfer or contractors who require smaller strap lengths, and packaged in portable 10" square cartons. 150! End Length Gauge 14! 16 Code CS16 Finish: galvanized. Some products available in Z-Max; contact factory. Installation: wood shrinkage after strap installation across horizontal wood members may cause strap to buckle outward. Codes: BOCA, ICBO, SBCCI NER-413 and NER-499; Dade County FL 93-1016.1. CS16 DECK-TIE CONNECTORS Code Material: DRT8 is 18 gauge, DPT5 and 7 are 14 gauge. DPT7 DRT8 Finish: Z-max Installation: DPT5 and 7: testing shows similar strength and deflection limits when compared with 4 x 4 posts attached to 2 x 8 rim joists with two 1⁄2" machine bolts placed 31⁄2" apart. Install in pairs at a recommended minimum center-center spacing of 5". Use two 3"8" through bolts and 5–10d x 11$2" nails for DPT5 (5–10d commons for DPT7) per tie. DRT8 Deck Railing Tie: eliminates nailing into the top of hand railing. Attaches 2 x 4 and 2 x 6 hand railing to posts. Use four #8 x 11⁄4" flathead wood screws. Drive prongs into post, then two screws into the post and two screws into the railing. 415-824-4300 DRT8 81 SIMPSON PRODUCTS DS DRYWALL STOP Code Eliminates costly blocking at top plate, end walls, and corners. A typical residence will use several hundred of these inexpensive clips with a substantial savings in blocking and labor. The installation prongs provide even more labor savings. DS1 Material: 20 gauge. Finish: galvanized. Installation: 16" on center or less, using 8d commons. Codes: BOCA, ICBO, SBCCI No. NER-413. DS EPC POST CAPS Size W1 W2 L1 L2 L3 No 4x4 4x4 4x6 4x6 4x6 4x6 6x6 6x6 39⁄16" 39⁄16" 39⁄16" 39⁄16" 51⁄2" 51⁄2" 51⁄2" 51⁄2" 39⁄16" 39⁄16" 51⁄2" 51⁄2" 39⁄16" 39⁄16" 51⁄2" 51⁄2" 25⁄8" 25⁄8" 25⁄8" 25⁄8" 49⁄16" 49⁄16" 49⁄16" 49⁄16" 11" 11" 13" 13" 11" 11" 13" 13" 73⁄8" 73⁄8" 91⁄4" 91⁄4" 73⁄8" 73⁄8" 91⁄4" 91⁄4" EPC44-16 EPC44 EPC46-16 EPC46 EPC64-16 EPC64 EPC66-16 EPC66 EPC SSTB ANCHOR BOLTS • Rolled threads for tensile capacity. • Stamped bolt head. • Stamped embedment line. Size Code 16" 20" 24" 28" SSTB16 SSTB20 SSTB24 SSTB28 Special Order 82 Allowable Tension Load (133) 1.2 Model7 Stemwall Dia Length Avg Concrete Concrete Concrete No. Width Ult f9 c=2500psi BLock BLock End 5 5 6 13640 ⁄8 17 ⁄8 4420 1850 SSTB16 4780 5⁄8 215⁄8 14745 6 4600 1850 SSTB20 4780 5⁄8 25 5⁄8 14745 6 5175 1850 SSTB24 4780 7⁄8 29 7⁄8 32700 8 10100 4815 SSTB28 6385 7⁄8 34 7⁄8 32700 8 10100 4815 SSTB34 6385 7⁄8 36 7⁄8 32700 8 10100 4815 SSTB36 6385 415-824-4300 SIMPSON PRODUCTS FLOOR BEAM LEVELERS Height Jack piers and standard floor beam levelers offer unique leveling simplicity during and after construction. JPs allow two simple methods of installation for economy and design versatility. Both models are adjustable; see table. Threaded (Min-Max) Rod Length 2”-4” 5”-7” 13”-18” 43⁄4" Material: 12 gauge plates, 3⁄4" threaded rod, 3⁄4" steel pipe. 4" 8" Code JP44 J57 J1318 Finish: None. Connectors installed in damp areas, or corrosive environments that are not exposed to rain or periodic washing, will deteriorate at a faster rate. Corrosion-resistant finish and maintenance can improve the connectors service life. Installation: Use all specified fasteners; see general notes. Holes are provided for installation with 16d commons. Do not use J/JPs for dynamic jacking of structures, such as houses. Codes: BOCA, ICBO, SBCCI No. NER-413. City of L. A. No. RR JP FOUNDATION ANCHORS This series is for retrofit or new construction. These products may be used together as a system or in individual applications, designed and tested for earthquake and high wind conditions. installation.Material: 12 gauge. FA anchors eliminate vertical drilling by nailing into the top of the mudsill. They facilitate installation when vertical space is limited, and resist forces between the foundation and mudsill. Codes: BOCA, ICBO, SBCCI Nos. NER-469 (FA8, FJA); City of LA No. RR25158. Finish: galvanized. Qty 1⁄2" 2 2 2 1⁄2" Installation: select and install concrete anchor bolts in accordance with the manufacturer’s recommendations. FJA foundation joist anchors nail or bolt directly into floor joist, and provides a direct connection between the foundation and joist. It provides uplift and lateral resistance. FSA foundation stud anchors nail or bolt to floor joists or nail to studs. Plywood shearwall may require nitching with stud-to-foundation Diameter 1⁄2" FJA FA FSA 415-824-4300 83 Code FA8 FJA FSA SIMPSON PRODUCTS H SEISMIC AND HURRICANE TIES Gauge The H connector series provides wind and seismic ties for trusses and rafters. Code 18 H1 H2 H2.5 H3 H4 H5 H6 Finish: galvanized; also available in stainless steel or Z-Max. 20 18 16 Installation: H1 can be installed with flanges facing outwards. When installed inside a wall, a birdsmouth cut is required. H2.5, H3, H4, and H5 ties are shipped in equal quantities of separate rights and lefts. H2 Codes: BOCA, ICBO, SBCCI Nos. NER-422, NER-393, NER-499; Dade County, FL No. 96-0719.10; City of L.A. No. RR 24818. H3 H2.5 H6 H1 H5 H4 HH HEADER HANGERS For fast, accurate installation of door and window headers and other cross member details. HH header hangers speed up the job, strengthen the frame, and eliminate the need for trimmers. Width Height 39⁄16" 51⁄2" 27⁄8" 51⁄4" Code HH4 HH6 Material: 16 gauge. Finish: galvanized. Codes: BOCA, ICBO SBCCI No. NER413; Dade County, FL No. 93-0828.4; City of L.A. No. RR 25119. HH 84 415-824-4300 SIMPSON PRODUCTS HDA HOLDOWNS Base Body Holdowns are used to transfer tension loads between floors, to tie pulins to masonry or concrete, etc. Use for overturn requirements and other applications to transfer tension loads. All HDAs are selfjigging, ensuring code-required minimum 7! bolt diameter spacing from the end of the wood member. Gauge Gauge HB 7" 3" 3⁄8 " 12" 41⁄2" 10" 51⁄4" 7" 63⁄16" SB W 21⁄2" 3" 31⁄2" HD6a, HD8A, HD10A’s seat design allows greater installation adjustability. An overall width of 31⁄4" for the HD6A, HD8A and HD10A provides for an easy fit in a standard 4x wall. H B SO 21⁄2" 8" 25⁄8" 33⁄16" 93⁄8" 31⁄2" 31⁄8" 111⁄16" 37⁄16" 143⁄8" 177⁄8" CL " 11⁄2" 1⁄2" 21⁄16" 9⁄16" 21⁄16" 1⁄4 Code HD2A HD5A HD6A HD8A HD10A Special Features: single piece non-welded design results in higher capacity. Load transfer plate eliminates the need for a seat washer. Fewer inspection problems. Finish: galvanized. HD8A may be ordered HDG; check with the factory. Installation: for an improved connection, use a steel nylon locking nut or a thread adhesive on the anchor bolt. Bolt holes shall be a minimum of 1⁄32" to a maximum of 1⁄16" larger than the bolt diameter (per 1991 NDS, section 8.1.2.1.) Standard washers are required on stud bolt nuts against the wood. The Load Transfer Plate is an integral part of the HDA Hold down and no washer is required. Locate on wood member to maintain a minimum distance of seven bolt diameters from the end of the member to the centerline of the first bolt hole (HDAs are self-jigging; minimum required distance is automatically maintained when end of wood member is flush with the bottom of the holdown.) To tie double 2x members together, the designer must determine the fasteners required to bind members to act as one unit without splitting. For holdowns installed on the mudsill, anchor bolt nuts should be finger-tight plus 1⁄3 to 1⁄2 turn with a wrench, with consideration given to possible future wood shrinkage. Care should be taken to not over-torque the nut, which may lead to premature anchor bolt failure. HD5A Stud bolts should be snugly tightened (per 1991 NDS, section 8.1.2.4.) Codes: BOCA, ICBO, SBCCI Nos. NER-393, NER-469; City of L.A. Nos. RR 24818 and RR 25158. HL HEAVY ANGLES AND GUSSETS GA Versatile angle gussets and heavy angles promote standardization and construction economy, and are compatible with Strong-Tie structural hardware. 7 7 7 Finish: Simpson gray paint. L D1 D2 D3 D4 Code 31⁄4" 21⁄2" 11⁄4" 31⁄4" 53⁄4" 5" 5" 11⁄4" 11⁄4" — 21⁄2" 21⁄2" 2" 2" 2" — — 21⁄2" HL33 HL35G* HL55 HL35G* IN STOCK Options: gussets may be added to HL models when L%5" (specify G after model number, as in HL46G.) 415-824-4300 W1 & W2 85 SIMPSON PRODUCTS HU FACE MOUNT HANGERS Joist Size Most models have triangle and round holes, which give high loads when filled with common nails. These heavy-duty connectors are designed for schools and other structures requiring additional strength, longevity and safety factors. 3!x12! 2x4 4x 6 4x 8 4 x 10 4 x 12 6x6 6x8 6 x 10 6 x 12 HU min. nailing fill round holes. HU max. nailing fill round and triangle holes. Can be installed filling round holes only, or filling round and triangle holes for maximum values. Gauge W H B 14 29⁄16" 39⁄16" 105⁄8" 27⁄8" 53⁄16" 613⁄16" 85⁄8" 105⁄16" 43⁄16" 513⁄16" 75⁄8" 93⁄8" 21⁄2" 51⁄2" Code HU312 HU44 HU46 HU48 HU410 HU412 HU66 HU68 HU610 HU612 Codes: BOCA, ICBO, ICBO No. 5117; Dade County, FL No. 960719.09; City of L.A. Nos. RR 24947, RR 24818. HU68 HUC FACE MOUNT HANGERS Concealed flange. Joist Size 4x 6 4x 8 4 x 10 4 x 12 6x6 Gauge W H B 14 29⁄16" 105⁄8" 21⁄2" Code 39⁄16" 51⁄2" 613⁄16" 85⁄8" 105⁄16" 43⁄16" HUC46 HUC48 HUC410 HUC412 HUC66 Gauge W H B Code 14 29⁄16" 105⁄8" 613⁄16" 85⁄8" 105⁄16" 21⁄2" HUC412 Concealed Flanges HUS FACE MOUNT HANGERS Joist Size Provides intermediate load-carrying capacity. Available with the head flanges turned. 4x 6 4x 8 4 x 10 4 x 12 Codes: BOCA, ICBO, SBCCI Nos. NER-209, NER-413, NER-421, NEW499; Dade County, FL No. 930828.8, 93-0824.07; City of L.A. Nos. RR 24949, RR 25076. HUS46 HUS48 HUS410 HUS412 HUS412 86 415-824-4300 SIMPSON PRODUCTS IS INSULATION SUPPORTS Size Easy one-hand installation to hold insulation in place. Mitered edges ensure a tight fit when installed between joists. Code 151⁄2" 231⁄2" IS16 IS24 Installation: Install insulation supports between joists. IS16 (151⁄2" long) for 16" o.c. spacing; IS24 (231⁄2" long) for 24" o.c. spacing. Follow the insulation manufacturer’s installation recommendations. LU FACE MOUNT HANGERS Joist Size Value engineered for strength and economy! Just a tap of the hammer at each speed prong secures the LU for easy nailing. Precision formed — engineered for installation ease and design value. 2x4 2 x 6, 8 2 x 8, 10 2x10, 12, 14 Gauge W H B 20 19⁄16" 31⁄8" 43⁄4" 63⁄8" 713⁄16" 11⁄2" Code LU24 LU26 LU28 LU210 Codes: BOCA, ICBO, SBCCI No. NER-393.; Dade County, FL No. 960719.09; City of L.A. Nos. RR 24947, RR 24818. LSSU LIGHT SLOPED/SKEWED U HANGERS Joist Size All models are skew- and slopeadjustable on the job site! Attach joists or rafters to headers, sloped up or down, and skewed left or right, up to 45º. 2x8 2 x 10 & up 3 x 10 & up W H 19⁄16" 71⁄8" 19⁄16" 29⁄16" 81⁄2" 81⁄2" Material: 18 gauge. Finish: galvanized. Installation: attach the sloped joist at both ends so that the horizontal force developed by the slope is fully supported by the supporting members. Codes: BOCA, ICBO, SBCCI Nos. NER-209, NER-421, NER-432. City of L.A. Nos. RR24949, 25074 and 25076. LSSU 415-824-4300 LSSU28 87 Code LSSU28 LSSU210 LSSU310 SIMPSON PRODUCTS LUS FACE MOUNT HANGERS Joist Size A light duty joist hanger with the lowest installed cost. Speed prongs secure the LUS for easy nailing. Gauge 2’x 4’ 18 2’x 6’,8’ 2’x 8”,10’ 2’x 10’, 12’, 14’ 4’x 4’ 4’x 6’, 8’ 4’x 8’, 10’ 4’x 10’, 12’, 14’ 4’x 12’ , 14’ DBL 2’x 4’ DBL 2’x 6’, 8’ DBL 2’x 8’, 10’ DBL 2’x 10’, 12’, 14’ MONKEY PAW™ ANCHOR BOLT HOLDERS 2’x 4’ H B Code 19⁄16” 31⁄8” 43⁄4” 65⁄8” 713⁄16” 3” 43⁄4” 63⁄4” 83⁄4” 103⁄4” 31⁄8” 47⁄8” 7” 9” 13⁄4” LUS24 LUS26 LUS28 LUS210 LUS44 LUS46 LUS48 LUS410 LUS414 LUS24-2 LUS26-2 LUS28-2 LUS210-2 39⁄16” 31⁄8” Bolt Size Offers significant savings over plywood or 2x wood holders. Use the MKP5/8 to install the SSTB16, 20, and 24. May be used several times. Stabilizes bolt by providing three-point support against lateral concrete pressure. Alignment arrows (left or right) match the SSTB bolt head arrow. Stamped for 2x4 ro 2x6 mudsill placement. No nut required to hold bolt in place. When removed, the MKP cleans the bolt thread of concrete. W Dia 5⁄8" 2” Finish galvanized Code MKP5⁄8 MKP 5/8” with SSTB16 NAILS Description Strong-Tie nails and structural fasteners have been developed as the optimum fasteners for connector products. Special lengths afford economy of purchase and installation, and depth compatibility with framing members. Nail specifications include head size, thickness, steel and shank design, and point configuration to ensure conformity to published values. (8d) 101⁄4GA x 11⁄2" Smooth Shank (10d) 9GA x 11⁄2" Smooth Shank (16d) 8GA x 21⁄2" Smooth Shank (20d) 0.192 x 21⁄8" Annular Ring (20d) 0.192 x 13⁄4" Annular Ring 0.250 x 21⁄2" Annular Ring 88 Metric Equivalent Finish Code 3.3MM x 38.1MM 3.8MM x 38.1MM 4.1MM x 63.5MM 4.9MM x 54.0MM 4.9MM x 44.5MM 6.4MM x 63.5MM HDG HDG Bright Bright Bright Bright N8 N10 N16 N20AN N20A N54A 415-824-4300 SIMPSON PRODUCTS NAIL STOPPERS Help prevent nails from piercing water pipes and electrical lines. Installed over utilities that prevent framing members the NS provides a warning and allows repositioning of the nail. 16 gauge steel conforms to the National Electric Code. Install with 8d commons or prongs. Size 3" Material Finish 16GA galvanized Code NS1 NS1 or NS2 PB POST BASES Locking prongs eliminate bolts or inserts in concrete. One-piece design assures maximum strength. Finish: 12 gauge galvanized. Installation: Holes are provided for installation with either 16d commons or 1⁄2" bolts. A 2" minimum sidecover is required to obtain the full load. Not recommended for non-topsupported installations such as fences. Width Length 39⁄16" 31⁄4" 4" 51⁄2" 51⁄2" 31⁄4" 31⁄4" 53⁄8" Code PB44 PB44R PB46 PB66 Codes: BOCA, ICBO, SBCCI NER443. Dade Co., FL No. 92-0828.05; City of L.A. RR 25149. 2” minimum sidecover PB44 PC POST CAPS PC Size W1 W2 L1 L2 L3 No 4x4 4x4 4x6 4x6 4x6 4x6 6x6 6x6 39⁄16" 39⁄16" 39⁄16" 39⁄16" 51⁄2" 51⁄2" 51⁄2" 51⁄2" 39⁄16" 39⁄16" 51⁄2" 51⁄2" 39⁄16" 39⁄16" 51⁄2" 51⁄2" 25⁄8" 25⁄8" 25⁄8" 25⁄8" 49⁄16" 49⁄16" 49⁄16" 49⁄16" 11" 11" 13" 13" 11" 11" 13" 13" 73⁄8" 73⁄8" 91⁄4" 91⁄4" 73⁄8" 73⁄8" 91⁄4" 91⁄4" PC44-16 PC44 PC46-16 PC46 PC64-16 PC64 PC66-16 PC66 PLATE STRAPS Material 16ga RPS 415-824-4300 89 L H 11⁄2" 11⁄2" 11⁄2" 185⁄16" 225⁄16" 285⁄16" Code RPS18 RPS22 RPS28 SIMPSON PRODUCTS PLYWOOD SHEATHING CLIPS Size Material Finish 1⁄2" 20 gauge galvanized Code PSC04 PSC05 PSC06 5⁄8" 3⁄4" Provides 1/8” gap PSCL PREDEFLECTED HOLDOWNS The Predeflected Holdown (PHD) is a revolutionary development in holdown connections. This connector is a predeflected during manufacturing, to virtually eliminate deflection from material stretch. Gauge W H B CL 14 3" 95⁄16" 119⁄16" 1313⁄16" 173⁄16" 27⁄8" 27⁄8" 13⁄8" 13⁄8" 12 10 Code PHD2 PHD5 PHD6 PHD8 Wood screws reduce slip due to overdrilled bolt holes. Smaller centerline reduces eccentricity in the stud. No stud bolts to countersink. the slot in the seat provides anchor bolt adjustment. Connectors 3" width fits easily on a 4x wall. Material: see table. Finish: galvanized. Installation: place over the anchor bolt. Install Simpson’s SDS1⁄4"x 3" wood screws (sold separately.) For an improved connection, use a steel nylon locking nut or a thread adhesive on the anchor bolt. To tie double 2x members together, the designer must determine the fasteners required to bind members to act as one unit without splitting the wood. PHD Codes: submitted to ICBO and City of L.A. in 10/96. REINFORCING AND SKEWABLE ANGLES L – Curved metal speed prong reduces labor and overall construction cost. Staggered nail pattern reduces the possibility for splitting and allows installation on both sides of a member. LS – Field-adjustable angles attach members intersecting at angles. Bend one time only. Joist must be constrained against rotation (for example, with solid blocking) when using a single LS per connection. Codes: BOCA, ICBO, SBCCI Nos. NER-413, NER443; City of L.A. Nos. RR 25119, 25149 Size Material 3" 5" 7" 9" 33⁄8" 47⁄8" 63⁄8" 16GA 18GA Code L30 L50 L70 L90 LS30 LS50 LS70 L70 90 415-824-4300 SIMPSON PRODUCTS ROTATED COLUMN END CAPS Width1 The industry standard column cap. Precision factory gang-punched holes speed installation. 35⁄8" 35⁄8" 51⁄4" 51⁄2" Material: CC44, CC46, CC64, CC66 are 7 gauge; all others are 3 gauge. Width2 35⁄8" 51⁄2" 51⁄2" 51⁄2" Finish: Simpson gray paint; may be ordered HDG. Options: straps may be rotated 90º where W1% W2. For special, custom, or rough cut lumber sizes, provide dimensions. An optional W2 dimension may be specified with any column size given (note that the W2 dimension on straps rotated 90º is limited by the W1 dimension.) Column caps with W1, L, H1, and hole schedules different from the shown dimensions may be special Width1 CC66 ordered. Provide a drawing to ensure accuracy. For end conditions, specify ECC. L dimensions will vary from 51⁄2 to 101⁄2. Uplift loads do not apply to the ECC. ECC9 and 10 use four beam bolts. SIMPSON STRONG-DRIVE® 4CUT™ INTERIOR AND EXTERIOR SCREW The Simpson Strong-Drive® screw (SDS) is a 1⁄4" diameter structural wood screw ideal for various connector installations as well as wood-to-wood applications. It installs with no predrilling and has been extensively tested in various applications. For 2007 the SDS is new and improved with a patented new easy driving tip and a corrosion resistant coating. 35⁄8" 35⁄8" 51⁄4" 51⁄2" 51⁄2" 91 35⁄8" 51⁄2" 51⁄2" 35⁄8" 51⁄2" CC H1 Code 7" 11" 13" 11" 4" 61⁄2" 8" 61⁄2" CC44 CC46 8CC51⁄4-6 CC66 ECC H1 Code 51⁄2" 81⁄2" 91⁄2" 71⁄2" 71⁄2" 4" 61⁄2" 8" 61⁄2" 61⁄2" ECC44 ECC46 ECC51⁄4-6 ECC64 ECC66 Length Size Qty Finish 11⁄2" 2" 21⁄2" 3" 31⁄2" 41⁄2" 6" 25/BOX 25/BOX 25/BOX 25/BOX 10/BOX 10/BOX 10/BOX Double Barrier Size Qty Finish 300/CASE 250/CASE 200/CASE 150/CASE 125/CASE 100/CASE 100/CASE Double Barrier 11⁄2" 2" • The patented 4CUT™ tip has a square 21⁄2" core and serrated threads to reduce • A new Double-Barrier Coating 3" installation torque and make driving 31⁄2" finish provides corrosion easier with no predrilling and minimal resistance superior to hot-dip 41⁄2" wood splitting galvanization. Now one screw 6" • 3⁄8" hex washer head is stamped with can handle interior, exterior the No-Equal sign and fastener length and certain pressure-treated for easy indentification after installation. wood applications 415-824-4300 Width2 Length Code 9DBB14 9DBB20 9DBB24 9DBB30 9DBB34 9DBB44 9DBB60 Code 9DBC14 9DBC20 9DBC24 9DBC30 9DBC34 9DBC44 9DBC60 SIMPSON PRODUCTS STANDOFF POST BASES Provides tested capacity. Features 1" stand-off height above concrete floors, code-required when supporting permanent structures that are exposed to the weather or water splash, or in basements. Reduces the potential for decay at post and column ends. ABE and ABU’s base design includes anchor bolt adjustment slot. Four-sided stand-off plate increases download support and provides attractive appearance. 2” minimum sidecover W1 W2 39⁄16" 31⁄2" 39⁄16" 51⁄2" 39⁄16" 51⁄2" 39⁄16" 31⁄2" 51⁄8" 31⁄2" 57⁄16" 31⁄2" D L — — 5" 71⁄8" 67⁄8" 31⁄2" 31⁄2" 3" 13⁄4" 21⁄4" 3" 21⁄4" HB Code 13⁄4" 5⁄8" 45⁄16" 41⁄2" 37⁄16" ABE44 ABU44 ABU66 CBS44 CBS66 PBS44 ABE44 CBS and PBS embed into wet concrete up to the bottom of the 1" standoff base plate. A 3" minimum side cover is required to obtain the full load for CBS; 2" for PBS. Holes in the bottom of the PBS and CBS straps allow for free concrete flow. 1” standoff satisfies code requirements 3” minimum sidecover 2” minimum sidecover 6 gauge, galvanized. Some products available in Z-Max. Not recommended for non-topsupported installations such as fences. For pre-poured anchors, embed 4& into concrete. For epoxy or wedge anchors, select and install according to anchor manufacturer’s recommendations; anchor diameter shown in table. Install requires washer. CBS44 PBS44 Codes: BOCA, ICBO, SBCCI Nos. NER-422, NER-432, NER-469; City of L.A. Nos. RR 25064, 25074, 25158; Dade County FL No. 93-1016.1 STRAP TIES Piling straps connect wood pilings to floor girders in elevated structures. Hot-dipped galvanized for greater corrosion resistance. Install where plates or soles are cut, at wall intersections, and as ridge ties. Codes: BOCA, ICBO, SBCCI No.s NER-413 and NER-443; Dade County, FL No. 93-0828.7. City of L.A. Nos. RR 25119, 25149. Width Length Material Code 21⁄16" 21⁄16" 21⁄16" 21⁄16" 11⁄2" 27" 37" 48" 60" 185⁄16" 225⁄16" 285⁄16" 95⁄16" 1213⁄16" 165⁄16" 12GA MST27 MST37 MST48 MST60 RPS18 RPS22 RPS28 ST292 ST2122 ST2115 ST6215 ST6224 ST22 ST6236 21⁄16" 21⁄16" 3⁄4" 21⁄16" 21⁄16" 11⁄4" 21⁄16" MSTI 92 10GA 16GA 20GA 16GA 235⁄16" 215⁄8" 3313⁄16" 14GA 415-824-4300 SIMPSON PRODUCTS SUR/SUL SKEWED 45º HANGERS Joist Size Standardized and code-listed 45º skewed hangers. Angled slots direct nails to allow speedy and proper installation of the nails. W H B A1 A2 Code 2 x 6,8 2 x 10,16 19⁄16" 19⁄16" 5" 81⁄8" 2" 2" 1" 1" 13⁄8" 13⁄8" SUR/L26 SUR/L210 Material L H B Qty Dia Code 7GA ptd 7GA ptd 7GA ptd 7GA ptd 7GA ptd 7GA ptd 7GA ptd 7GA ptd 6" 8" 12" 16" 6" 12" 12" 16" 6" 8" 12" 16" 5" 8" 12" 16" 11⁄2" 2" 2" 21⁄2" 11⁄2" 2" 2" 21⁄2" 3 3 3 4 3 3 3 6 3⁄8 66L 88L 1212L 1616HL 66T 128T 1212T 1616HT Material: 16 gauge. Finish: galvanized. Installation: these hangers will normally accommodate a 40º to 50º skew. SUR=skewed right; SUL=skewed left. The joist end may be square cut or bevel cut. Codes: ICBO No. 5117; City of L.A. RR 24947; Dade County, FL No. 930824.07. SUL T AND L STRAP TIES 66T 66L 1⁄2 1⁄2 5⁄8 3⁄8 1⁄2 1⁄2 5⁄8 TS TWIST STRAPS Length Twist straps provide a tension connection between two wood members. An equal number of right and left hand units are supplied in each carton unless ordered otherwise. 9" 115⁄8" 173⁄4" Material: 16 gauge. Finish: galvanized. Some products available in stainless steel and ZMax. Installation: use all specified fasteners. 415-824-4300 TS 93 Total Fasteners 8-16d 10-16d 14-16d Code TS9 TS12 TS18 SIMPSON PRODUCTS TENSION TIES Tension ties are ideal for retrofit or new construction and provide postpour, concrete-to-wood connections. MTT28B amy be ordered HDG; check with the factory. Strap Plate W L CL Code 12GA 7GA 21⁄16" 27" 15⁄8" MTT28B Codes: BOCA, ICBO, SBCCI No. NER-393; City of L.A. No. RR24818. MTT28B TIE PLATES Width TPs are nail-on tie plates. TPAs are flanged for added support. Length No of Nail Holes 11" 9" 11" 7" 50 54 66 60 31⁄8" 41⁄8" 41⁄8" 53⁄4" Material: 20 gauge. FInish: galvanized. Installation: holes are sized for 8d common or 8d x 11⁄2" nails. Code TP311 TP49 TP411 TP57 TP U FACE MOUNT HANGERS Joist Size The standard U hanger provides flexibility of joist to header installation. Some models have speed prongs for fast installation. Versatile fastener selection with tested allowable loads. Gauge 2x4 16 2 x 6,8 2 x 10, 12, 14 2 x 14, 16 DBL 2 x 4 DBL 2 x 6, 8 DBL 2 x 10 Rough 2 x 4 Rough 2 x 6, 8 Rough 2 x 10,12,14 W H B 19⁄16" 31⁄8" 11⁄2" 43⁄4" 713⁄16" 10" 3" 5" 81⁄2" 35⁄8" 55⁄8" 91⁄8" 2" 31⁄8" 2" 2" 2" Code U24 U26 U210 U214 U24-2 U26-2 U210-2 U24R U26R U210R U210 94 415-824-4300 SIMPSON PRODUCTS UNIVERSAL FOUNDATION PLATE Code The UFP10 Retrofit Foundation Plate cuts installation time in half! Designed to connect when the mudsill is offset from the foundation up to 21⁄2" or extended beyond the foundation up to 1⁄2". UFP may be used in place of FA, HFA and FAP. UFP10 Material: 14 gauge. Finish: galvanized. Codes: City of L.A. RR 25281. UFP10 on a straight foundation with offset mudsill WALL BRACING Length Designed to fulfill the same code bracing requirements as 1 x 4 let-in bracing, but less expensive and faster to install. Resists racking during construction. Not designed to replace shearwall load-carrying components. 53⁄8" 9! 11! 43⁄8" 11! 43⁄4" 11! 43⁄8" Material: 16 gauge. Finish: galvanized. Installation: WB and WBC: install in “X” pairs or in opposing “V” fashion. Use with 16" or 24" o.c. studs. CWB: use with 16" o.c. studs. Established run-line using the bracing as a straight edge. Single cut a saw kerf 1" deep along the run line. If the wall is pre-framed on the floor, place the part into the saw kerf, and put one nail into the top plate, bottom plate and studs according to the nailing schedule. WB Codes: BOCA, ICBO, SBCCI Nos. NER-413, NER-432, NER-443, NER422; Dade County, FL. 93-0824.07: City of L.A. RR 25074, RR 25119, RR 25149. 415-824-4300 95 Angle Wall Size Code 8! 60º 45º WB106 WB126 WB126C CWB126 SIMPSON PRODUCTS WT WEDGE FORM TIES Especially designed for low foundation wall applications. 5⁄8" wide formed “V” design for rigidity allows accurate form spacing and support. Wall Thickness Code 6" 8" 10" 12" Material: 18 gauge. Finish: galvanized. WT6 WT8 WT10 WT12 WT8 Installation: not recommended for wall pours greater than 4! high. Fits 1" or 2" nominal form lumber. Wall thickness from 6" to 12". WI WEDGE Material: 18 gauge. Gauge Finish: galvanized. 18 Code W1 Installation: use two 31⁄2" long wedges for each tie. W1 COLUMN CAP W1 W2 L H Qty 3/” 51/2” 3/” 51/2” 7” 11” 4” 61/2” EA 5 8 5 8 EA Code CC44HDG CC66HDG COLUMN CAP W1 W2 L1 L2 H Qty Code 3/” 51/2” 3/” 51/2” 5/” 71/2” 6/” 91/2” 4” 61/2” EA ECC44HDG ECC66HDG 5 8 96 5 8 1 2 1 2 EA 415-824-4300 SIMPSON PRODUCTS STAND OFF POST BASE W 39/16” 51/2” L H Qty 39/16” 59/16” 21/4” 3” EA EA Code AB44Z AB66Z REINFORCING ANGLE Qty L50 EA EA Code L50Z L70Z L70 REGULAR POST BASES W 39/16” 51/2” L Qty 31/4” 51/4” EA EA Code PB44Z PB66Z 2” MINIMUM SIDECOVER POST CAP W1 W2 L1 L2 L3 Qty Code 3/ ” 51/2” 3/ ” 51/2” 2/” 49/16” 11” 13” 7/ ” 91/4” EA PC4416Z PC66Z 9 16 415-824-4300 97 9 16 5 8 5 16 EA SIMPSON PRODUCTS HOLDDOWNS COLUMN BASES HB4 SB W H B 49/16” 63/16” 21/2” 31/2” 23/4” 31/4” 8” 149/16” 29/16” 37/16” 1 5/16" for 5/8" bolts 1 1/2" for 3/4" bolts CL Qty Code /” / ” 17/16” 21/16” EA HD2AHDG HD8AHDG 3 8 9 16 EA W1 W2 D Qty Code 3/ ” 51/2” 3/ ” 51/2” 8” 8” EA CB44HDG CB66HDG 9 16 DOUBLE SHEAR JOIST HANGERS SO W 1/ ” 19/16” 31/8” 19/16” 31/8” 19/16” 31/8” 39/16” 39/16” 39/16” 9 16 9 16 EA H B Qty Code 3/” 43/4” 47/8” 65/8” 7” 713/16” 9” 3” 43/4” 63/4” 1/” 13/4” 2” 13/4” 2” 13/4” 2” 2” 2” 2” EA LUS24Z LUS26Z LUS26-2Z LUS28Z LUS28-2Z LUS210Z LUS210-2Z LUS44Z LUS46Z LUS48Z H Qty 11/2” EA 1 8 3 4 EA EA EA EA EA EA EA EA EA STAIRCASE ANGLES W 101/4” Code TA10Z TA9Z TA10 98 415-824-4300