miller dunwiddie TERMINAL BUILDING IMPROVEMENTSLANDSIDE PRE-SECURITY RESTROOM REMODEL THE EASTERN IOWA AIRPORT ARCHrTECrURE 123 North Third Street Suite 104 MinneapolisMN ~1-1657 www.millenlunwiddie.com p 612-337-0000 f 612-337-0031 C EDAR RAPIDS MATERIALS LOCATION MAP I EXISTING CONST. ~l!l ]:; ! \TI: ; !il;: ;W;!J!j j EARTH ,.. . ; ' I CAST-IN-PLACE CONC PZ'/Z1 PRECAST CONCRETE 17/V;/J CONCRETE BLOCK/ CMU 1<-'-::';; >C(I SAND, CONC, GYPSUM SHEET INDEX GENERAL GOOO G001 G1 03 G104 TITLE SHEET REFERENCE FLOOR PLAN- OVERALL TERMINAL PHASING PLANS - PHASES 1 & 2 PARTITION TYPES, DETAILS, AND FIXTURE MOUNTING HEIGHTS CIVIL C001 SITE PLAN DEMOLITION D100 D200 DEMOLITION FLOOR PLANS DEMOLITION EXTERIOR ELEVATIONS & WALL SECTION ARCHITECTURAL ~BRICK WffL?l STEEL, METAL STUD ~PARTICLE BOARD/O.S.B. E'll&"lCJ&Xl/1 BATT INSULATION ~RIGID INSULATION PROJECT LOCATION [ •: •: •: •:3 FOAM INSULATION ~EIFS ABV ACP ADJ AED AFF ALUM BLDG BLKG BO BP BRKT CIP CL CLG CMU CONC CONT COOR CT cw DETL DIA DIM DN DSP EA EJ EL ELEC EQ EQPT EXIST EXP EXT FAF FD FDN FE FF FGLASS FIN FLR FO FV FT FTG GA GALV GC GF GYPBD HM HT ID INSUL INT JT KO oc ABOVE ACOUSTICAL CEILING PANEL ADJUSTABLE AUTOMATIC ELEC DEFIBRILLATOR ABOVE FINISH FLOOR ALUMINUM BUILDING BLOCKING BOTTOM OF BID PACKAGE BRACKET CAST IN PLACE CHAIN LINK CEILING CONCRETE MASONRY UNIT CONCRETE CONTINUOUS COORDINATE CERAMIC TILE CURTAIN WALL DETAIL DIAMETER DIMENSIONS DOWN DOWNSPOUT EACH EXPANSION JOINT ELEVATION ELECTRICAL EQUAL EQUIPMENT EXISTING EXPOSED EXTERIOR FLUID APPLIED FLOORING FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FINISH FLOOR FIBERGLASS FINISH FLOOR FACE OF FIELD VERIFY FIRE TREATED FOOTING GAUGE GALVANIZED GENERAL CONTRACTOR GROUND FACE GYPSUM BOARD HOLLOW METAL HEIGHT INSIDE DIAMETER INSULATION INTERIOR JOINT KNOCKOUT LOCATION oc OD OFD OS OH OTB PC PERIM PLAM PLYWD PRE FIN PSF PT QT R RAD RD RDL REINF REQD REV RM RO SHT SIM SP ss SSTL STC STL STRUCT T T&G TEMP TO TS TYP UG UL UNO VB VERT VIF VR WI WD WR MAXIMUM MECHANICAL MANUFACTURER MINIMUM MOUNTED MASONRY OPENING METAL PANEL MOISTURE RESISTANT METAL MULLION NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVER FLOW DRAIN OVER FLOW SCUPPER OVERHEAD OPEN TO BELOW PRECAST PERIMETER PLASTIC LAMINATE PLYWOOD PREFINISHED POUNDS PER SQUARE FOOT PAINT QUARRY TILE RISER RADIUS ROOF DRAIN ROOF DRAIN LEADER REINFORCED/REINFORCING REQUIRED REVERSE ROOM ROUGH OPENING SHEET SIMILAR SPACE SOLID SURFACE STAINLESS STEEL SOUND TRANSMISSION CLASS STEEL STRUCTURE TREAD TONGUE & GROOVE TEMPORARY TOP OF TUBE STEEL TYPICAL UNDERGROUND UNDERWRITERS LABORATORY UNLESS NOTED OTHERWISE VINYL BASE VERTICAL VERIFY IN FIELD VAPOR RETARDER WITH WOOD WASTE RECEPTACLE EOOO E111 E211 E911 l;#i' AWzi~ PLYWOOD ~ 7%J FINISH WOOD PLUMBING welshme@kjww.com nietfeldtph@kjww.com PROJECT THE EASTERN IOWA AIRPORT P101 P111 P300 P500 P901 P911 UNDERFLOOR PLAN- PLUMBING 1ST FLOOR PLAN - PLUMBING PLUMBING RISER DIAGRAMS PLUMBING MATERIAL LIST UNDERFLOOR DEMOLITION PLAN - PLUMBING 1ST FLOOR DEMOLITION PLAN- PLUMBING Slgnatura "" TBD CEDAR RAPIDS, IOWA REVISED I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. FIRE PROTECTION FP111 FP911 TERMINAL BUILDING IMPROVEMENTS LANDS IDE PRE-SECURITY RESTROOM REMODEL I hereby certify that the portion of this technical submission described below was prepared by me or under my direct supervision and responsible charge. I am a duly Registered Architect under the laws of the State of Iowa. 1ST FLOOR PLAN- MECHANICAL MECHANICAL SCHEDULES & DETAILS 1ST FLOOR DEMOLITION PLAN - MECHANICAL 1ST FLOOR PLAN - FIRE PROTECTION 1ST FLOOR DEMOLITION PLAN - FIRE PROTECTION John M. Fleming Mark Description Date _,. 13323 ,... TBD BUILDING SECTION MARKER Slgnatura I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa. Brian J. Leavitt 17410 _,. DETAIL SECTION MARKER & CCNSULTANTS PROJECT MANAGER FOTH INFRASTRUCTURE & ENVIRONMENTAL, LLC. 3950 RIVER RIDGE DRIVE NE, SUITE A CEDAR RAPIDS, IOWA 52402 PH: (319) 365-9565 FAX: (319) 365-9631 CONTACT: ERIC SCOTT DAVE KAPLER EMAIL: eric.scott@foth.com dave.kapler@foth.com WALL SECTION MARKER A123 ENiliiiNEERING COVER SHEET - ELECTRICAL 1ST FLOOR PLAN- LIGHTING 1ST FLOOR PLAN - POWER AND SYSTEMS 1ST FLOOR DEMOLITION PLAN - ELECTRICAL J;:";>,:c;·,.:,:·'<·:l GYPSUM BOARD I ARCHITECT MILLER DUNWIDDIE ARCHITECTURE 123 NORTH THIRD STREET, SUITE 104 MINNEAPOLIS, MN 55401 PH' (612) 337-IJOOO FAX' (612) 337-ll031 CONTACT' JOELSTROMGREN EMAIL: jstromgren@millerdunwiddie.com ELECTRICAL M111 M500 M911 SYMBOLS MAX MECH MFR MIN MNTD MO MP MR MTL MULL NIC NOM NTS FLOOR PLANS AND DETAILS REFLECTED CEILING PLANS AND DETAILS ROOF PLANS, ROOF FRAMING & TOILET PARTITION SUPPORT FRAMING PLANS EXTERIOR ELEVATIONS & WALL SECTION DOOR TYPES, FRAME TYPES, DOOR SCHEDULE, STOREFRONT TYPES, & DETAILS ROOM FINISH FLOOR PLAN & INTERIOR ELEVATIONS- MEN'S RESTROOM ROOM FINISH FLOOR PLAN & INTERIOR ELEVATIONS- WOMEN'S RESTROOM FINISH FLOOR PLANS INTERIOR DETAILS Foth MECHANICAL I ELECTRICAL ENGINEER KJWW ENGINEERING CONSULTANTS 623- 26th AVENUE ROCK ISLAND, IL 61201 PH' (309) 768-0673 FAX' (309) 766-5967 CONTACT' MECH.- JOHN FLEMING ELEC. - MARK WELSH TECH.- PHIL NIETFELDT EMAIL: flemingjm@kjww.com OWNER THE CEDAR RAPIDS AIRPORT COMMISSION 2115ARTHUR COLLINS PARKWAY SW CEDAR RAPIDS, IOWA 52404-8951 MECHANICAL 1><1 ROUGH WOOD ABBREVIATIONS A100 A150 A170 A200 A500 A600 A601 A61 0 A650 PROJECT TEAM TBD Slgnatura ELEVATION MARKER ~ "" INTERIOR ELEVATION MARKER 0----~ BUILDING GRID LINE ELEVATION/HEIGHT MARKER 0>------- FIE1302 COMM. NO.: WALL TYPE DESIGNATOR DATE: STOREFRONT/WINDOW/LOUVER TYPE DESIGNATOR DRAWN: JRH CHECKED: JTS OCTOBER 28, 2013 PLAN DETAIL MARKER ©2013 Miller Dunwiddie Architecture, Inc. DRAWING TITLE DOOR IN THIS BID PACKAGE ( '- TITLE SHEET 1 REVISION MARKER GENERAL NOTES CODES 1. FINISH FLOOR REFERENCE ELEVATION OF 100'-ll" EQUALS 666'-0". BUILDING CODE 2. SEE SPECIFICATIONS AND DETAILS FOR LOCATIONS OF UNTREATED, PRESERVATIVE TREATED, AND FIRE-RETARDENT TREATED LUMBER. CITY OF CEDAR RAPIDS BUILDING CODE 2012 INTERNATIONAL BUILDING CODE I CITY OF CEDAR RAPIDS MECHANICAL CODE DRAWING NUI\1BER PLUMBING CODE 3. PROVIDE FT WOOD OR SHEET METAL BACKING AS REQUIRED FOR INSTALLATION OF CABINETS, MILLWORK, EQUIPMENT AND ACCESSORIES. 2012 INIFORM PLUMBING CODE CITY OF CEDAR RAPIDS PLUMBING CODE ELECTRICAL CODE 2012 NATIONAL ELECTRICAL CODE ENERGY CODE CITY OF CEDAR RAPIDS ELECTRICAL CODE 2009 IECC WITH AMENDMENTS GOOO I, 2 I J I 4 I s I 6 I 1 I a I 9 l1o I ELECTRICAL GENERAL NOTES 1. "1/E111" INDICATES DETAIL NUMBER/SHEET NUMBER. 2. " 3. 4. # "SE" " SYMBOL: INDICATES KEYED NOTE USED TO DESCRIBE ADDITIONAL INFORMATION OF WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL IT IS SHOWN WITH. J INDICATES LUMINAIRE IS SWITCHED DURING NORMAL OPERATION AND OPERATES FROM EMERGENCY BATTERY UPON LOSS OF POWER. CONNECT THE SWITCHING DEVICE TO THE BALLAST FOR NORMAL OPERATION. EXTEND "AN" UNSWITCHED PORTION OF THE SAME CIRCUIT TO THE FIXTURE FOR CONNECTION TO THE EMERGENCY BATTERY AND BALLAST. E TAG: J E HALF SHADED LUMINAIRE INDICATES LUMINAIRE HAS AN INTERNAL EMERGENCY BATTERY. LUMINAIRE KEY: F1 = FIXTURE TAG LS *IF LABEL IS ORIENTED HORIZONTALLY A / WILL SEPARATE THIS INFORMATION. EX: F1 / 1 / A / NL 6. 7. 8. D 0 DEVICE KEY: DEVICE SPEC SECTION: OC A = MOUNTING (IF APPLICABLE) U DESCRIPTION: JB 16111 JUNCTION BOX ECONN 16111 ELECTRICAL CONNECTION PANEL '###' EXISTING PANELBOARD - RECESS MOUNT PANEL '###' EXISTING PANELBOARD - SURFACE MOUNT EXISTING TRANSFORMER 16141 SWITCH - SINGLE POLE SW-LS-D 16141 DAYLIGHT LEVEL SENSOR - 1 ZONE DIMMING SW-OC-P-0 16141 SWITCH - OCCUPANCY SENSOR WALL SWITCH SW-OC-U 16141 OCCUPANCY SENSOR - ULTRASONIC 360 DEGREE COVERAGE SW-1P LUMINAIRE SE = SUBSCRIPT (IF APPLICABLE) 5. MOUNTING SUBSCRIPT KEY: F# 16510 LINEAR LUMINAIRES RECEPTACLES AND TELECOMMUNICATIONS OUTLETS: A MOUNT ABOVE COUNTER (+6" TO CENTERLINE ABOVE COUTNER OR BACKSPLASH. F# 16510 TROFFER F# 16510 DOWNLIGHT LUMINAIRE REFER TO SPECIFICATIONS FOR FULL DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES. F# 16510 INDUSTRIAL LUMINAIRE SD EXISTING FIRE ALARM SMOKE DETECTOR CEILING MOUNTED F EXISTING FIRE ALARM MANUAL PULL STATION EXISTING FIRE ALARM VISUAL NOTIFICATION DEVICE WALL MOUNTED REFER TO DRAWINGS FIRE ALARM AUDIO/VISUAL NOTIFICATION DEVICE - WALL MOUNTED LINE TYPE KEY: NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE) EXISTING TO REMAIN (LIGHT SOLID LINE) EXISTING TO BE REMOVED BY THIS CONTRACTOR (DARK SHORT DASHED LINE) V1 V3 V7 VH A1 A3 A7 AH VS FA-211 AS A1 A3 A7 AH ELECTRICAL INSTALLATION NOTES 1. CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITH NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN EACH PHASE. 3. FLUSH MOUNT ALL TOGGLE SWITCHES AT +42" FROM FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. TOGGLE SWITCHES MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED. 4. FLUSH MOUNT ALL DUPLEX RECEPTACLES AT +18" FROM FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED. 5. DUPLEX RECEPTACLES FOR ELECTRIC WATER COOLERS (EWC) SHALL BE CONCEALED BEHIND WATER COOLER ACCESS PLATE OR BE DIRECTLY BELOW AND CENTERED ON EWC. CONTRACTOR SHALL VERIFY TYPE OF EWC TO BE INSTALLED. 6. INSTALL ALL WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES AT 90" ABOVE FINISHED FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER, EXCEPT WHERE OTHERWISE NOTED. HEIGHT SHALL BE MEASURED TO THE TOP OF THE DEVICE. 7. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL FIRE ALARM DEVICES AND/OR SPEAKERS WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES IN CEILING TILE PATTERN. ELECTRICAL EQUIPMENT SHALL BE MOUNTED TO AVOID IMPEDANCE OF, OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF ELECTRICAL EQUIPMENT, ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE OTHER CONTRACTOR. 8. 9. FA-231 AS S THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADAAG (AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES). 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR SEALED INTO OPENINGS. LUMINAIRE SCHEDULE ELECTRICAL SYMBOL LIST REC-DUP-GFI CL - CEILING SURFACE WL - WALL UC - UNDER CABINET CV - COVE PL - POLE FR- FLANGED RECESSED O - OTHER ( SEE DESCRIPTION) DOOR: FA - FLAT ALUMINUM FS - FLAT STEEL RA - REGRESSED ALUMINUM RS - REGRESSED STEEL FINISH: PAF - PAINT AFTER FABRICATION ITEM F1 DESCRIPTION F1D SAME AS F1 EXCEPT WITH DIMMING. EXISTING SIMPLEX RECEPTACLE F1E SAME AS F1 EXCEPT WITH EMERGENCY BATTERY BACKUP EXISTING DATA OUTLET/ROUGH-IN EXISTING DUPLEX RECEPTACLE, 125V 16141 DUPLEX GFI RECEPTACLE, 125V ELECTRIC WATER COOLER END OF LINE SUPERVISION DEVICE EXISTING PAGING HEAD END EQUIPMENT PSMH - PULSE START METAL HALIDE CMH - CERAMIC METAL HALIDE O - OTHER (SEE DESCRIPTION) XL - EXTENDED LIFE XLP - EXTENDED LIFE & OUTPUT (TYPE) BALLAST: DIM07- 0-10V DIMMING BALLAST DIM10- LINE DIMMING BALLAST HL- HIGH / LOW LEVEL BALLAST ML- MULTI-LEVEL SWITCHING HP- HIGH PERFORMANCE / LBF L W L.E.D. OPEN DOWNLIGHT, PROVIDE WITH DECORATIVE GLASS TRIM RING. SIMPLEX RECEPTACLE EWC G- TEMPERED GLASS H- WALL WASHER P- POLY CARBONATE K- KSH12 .125" ACRYLIC K19- KSH19 .156" ACRYLIC L- LOW IRIDESCENT SPECULAR ALUM. N- NONE R- HIGH IMPACT DR ACRYLIC O- OTHER (SEE DESCRIPTION) (TYPE) BALLAST: EB- ELECTRONIC BALLAST EM- EMERGENCY BATTERY/BALLAST DALI- DIGITAL DIMMING BALLAST MV- MULTI-VOLTAGE ELECTRONIC 120V-277V #BF- BALLAST FACTOR DIMENSIONS EXISTING ELECTRICAL CONTRACTOR HS - HIGH PRESSURE SODIUM MH - METAL HALIDE SMH - SUPER METAL HALIDE ALL LAMPS FOR THIS PROJECT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. FLUORESCENT LAMP CORRELATED COLOR TEMPERATURE 5000°K, COLOR RENDERING INDEX (CRI) AT OR ABOVE 75, UNLESS NOTED OTHERWISE. LED LAMP COLOR RENDERING INDEX (CRI) AT OR ABOVE 80 FOR INTERIOR APPLICATIONS. PAGING SPEAKER, FROM OWNER'S ATTIC STOCK E.C. C- CLEAR ALZAK D- PARABOLIC F- FRESNEL REFER TO SPECIFICATION SECTIONS LIGHTING 26 51 00 AND EMERGENCY LIGHTING 26 52 00 FOR ADDITIONAL INFORMATION AND REQUIREMENTS. REFER TO DRAWINGS DESCRIPTION: (L/L) LENS/LOUVER: A- .125" ACRYLIC B- BLACK BAFFLE CATALOG NUMBER SHALL NOT BE CONSIDERED COMPLETE AND MATERIAL SHALL NOT BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. THE COMPLETE DESCRIPTION AND THE SPECIFICATION SHALL BE COORDINATED WITH THE CATALOG NUMBER TO DETERMINE THE EXACT MATERIAL AND ACCESSORIES TO BE ORDERED. THE FIRST MANUFACTURER LISTED IS THE BASIS FOR DESIGN. FIRE ALARM AUDIO/VISUAL NOTIFICATION DEVICE - CEILING MOUNTED ABBREVIATION: LAMP TECHNOLOGY: (Type) FL - FLUORESCENT CF - COMPACT FLUORESCENT HL - HALOGEN IN - INCANDESCENT LED - LIGHT EMITTING DIODE CSA - FINISH SELECTION BY ARCHITECT REFER TO DRAWINGS ELECTRICAL ABBREVIATIONS 10. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OF ELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION. CONTRACTOR SHALL REPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR. (MTG) MOUNTING: RE - RECESSED SP - SUSPENDED LAMPS H DIA 7" 6" MTG RE TYPE L.E.D. QTY 1 BALLAST MODEL 1000 LUMEN ARRAY VOLTS 277V TYPE L/L O 3500°K CCT TRIM RING: CTR6326L2-CLR-P DIM07 EM F1DE SAME AS F1 EXCEPT WITH DIMMING AND EMERGENCY BATTERY BACKUP F2 FLUORESCENT RECESSED PERIMETER FIXTURE, STAGGERED LAMPING, CONTINUOUS PARABOLIC LOUVER, PROVIDE CONTINUOUS HOUSING FOR LENGTH AS SHOWN ON PLANS. VERIFY DIMENSIONS FOR CONTINUOUS HOUSING WITH ARCHITECTURAL DRAWINGS AND FIELD CONDITIONS IN NEW WOMEN'S RR 115 AND NEW MEN'S RR 120. F3 RECESSED DIRECT WITH HIGH ANGLE ILLUMINANCE, MATTE ACRYLIC DIFFUSER, SINGLE LAMP CHAMBER F4 F5 APPROVED MANUFACTURER CON-TECH RA6LNC-435K27D2-CST6322L2-CLR DIM07 EM THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA AS SHOWN ON PLANS 8" 3" RE FL 1 32 WATT F32T8 PER 4' SECTION MV EB O MARK ARCHITECTURAL MP 4' 2' 5.3" RE FL 2 32 WATT F32T8 MV EB O DAYBRITE SOFTRACE DIFFUSE 2STG232 FOCAL POINT APOLLO 2 WHITE ANODIZED SIDE RAILS LIGHTOLIER HP90 LEDALITE PURE FX MARK ARCHITECTURAL MERIDIAN LDS CORELITE CLASS R3 L.E.D. CABLE LIGHT, 0.2 WATT L.E.D.S SPACED AT 2" ON CENTER, CLEAR LENS, PROVIDE CONTINUOUS LENGTH AS SHOWN ON PLANS, PROVIDE THE APPROPRIATE NUMBER OF STRINGS AND DRIVERS AS DETERMINED BY THE MANUFACTURER SPECIFICATIONS. AS SHOWN ON PLANS 1" 0.6" CV L.E.D. 0.2 WATT L.E.D. 277V DIM07 O TOKISTAR CRL-50-5000K ENCLOSED INDUSTRIAL WITH FIBERGLASS HOUSING, STAINLESS STEEL LATCHES, MOLDED IN PLACE GASKET, PEBBLED LENS, UL WET LOCATION 48" 7" A GUTH DC4 LITHONIA DMW232 H.E.WILLIAMS 92-4-232OC-A-WET PRUDENTIAL P-5362 METALUX VT2232 5000°K 5" CL FL 2 32WATT F32T8 MV FIE1302 APPLICABLE CODES 1 CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS. NATIONAL ELECTRICAL CODE: NEC 2011 EDITION WITH LOCAL AMENDMENTS BUILDING CODE: IBC 2012 : PAGING RISER DIAGRAM NO SCALE OCTOBER 28, 2013 GENERAL NOTES KEYNOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV JAN/MECH VESTIBULE VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FAMILY ROOM FIE1302 OCTOBER 28, 2013 VENDI 1 N 1ST FLOOR PLAN - LIGHTING SCALE: 1/8"=1'-0" O R T H KEYPLAN GENERAL NOTES KEYNOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FAMILY ROOM FIE1302 OCTOBER 28, 2013 VENDI 1 N 1ST FLOOR PLAN - POWER AND SYSTEMS SCALE: 1/8"=1'-0" O R T H KEYPLAN KEYNOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FIE1302 OCTOBER 28, 2013 VENDI 1 N 1ST FLOOR DEMOLITION PLAN - ELECTRICAL SCALE: 1/8"=1'-0" O R T H KEYPLAN MECHANICAL SYMBOLS LIST SYMBOL: DESCRIPTION: THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FAMILY ROOM FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N 1ST FLOOR PLAN - MECHANICAL HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR FAN COIL UNIT SCHEDULE - HYDRONIC SYMBOL FCU-1 SERVICE RESTROOM CFM EXT. S.P. IN W.C. EAT DB °F 0.2 75 300 HEATING COIL ELECTRICAL TOTAL MBH GPM EWT °F LWT °F W.P.D. FT. HD MOTOR (WATTS) VOLTPHASE DISCONNECT BY (NOTE A) CONTROLLER/STARTER 19.5 1.3 180 150 8.0 84 120-1 MFR MFR MANUFACTURER MODEL REMARKS TRANE FFC020 HIGH STATIC TYPE (NOTE A) LINEAR DIFFUSER SCHEDULE SYMBOL MATERIAL SLOT WIDTH NO. SLOTS BAR WIDTH BAR SPACING WIDTH INCHES LENGTH FEET PLENUM REQUIRED PLENUM INSULATION PLENUM INLET SIZE PATTERN CONTROL REQUIRED BALANCING DAMPER REQUIRED FINISH MANUFACTURER MODEL REMARKS LD-1 ALUMINUM 1" 3 N/A N/A 6" 4 YES WRAPPED SEE DWG. YES NO WHITE TITUS TBD NOTE 1, 2 NOTES: 1. CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING CONSTRUCTION. 2. PROVIDE WITH CONCEALED FASTENERS. SCHEDULE GENERAL NOTES: GRILLES REGISTERS & DIFFUSERS SCHEDULE SYMBOL MAT'L TYPE MARGIN (NOTE 1) INLET SIZE (INCH) FACE SIZE (INCH) VOLUME DAMPER REQ'D FINISH MANUFACTURER MODEL REMARKS CD-1 STEEL PANEL FACE LAY-IN SEE DWG. 24x24 NO WHITE TITUS OMNI FLUSH FACE PANEL RG-1 STEEL PERFORATED FACE LAY-IN SEE DWG. 24x24 NO WHITE TITUS PAR DUCTED RETURN RG-2 ALUMINUM 30° DEFLECTION 1 1/4" SEE DWG. INLET +2 NO WHITE TITUS 63FS HEAVY DUTY, CLEAR ANODIZED FINISH EG-1 STEEL PANEL FACE LAY-IN SEE DWG. 24x24 NO WHITE TITUS OMNI FLUSH FACE PANEL A. DISCONNECT AND CONTROLLER STARTER FURNISHED AND INSTALLED BY: MFR = MANUFACTURER EC = ELECTRICAL CONTRACTOR. MC = FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED BY ELECTRICAL CONTRACTOR MFR/EC = FURNISHED LOOSE BY MANUFACTURER INSTALLED BY ELECTRICAL CONTRACTOR ATC = AUTOMATIC TEMPERATURE CONTROL CONTRACTOR B. DISCONNECT TYPE: F = FUSED NF = NON-FUSED NOTES: 1. CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING CONSTRUCTION. 2. ALL RUN OUT DUCTWORK TO DIFFUSERS SHALL BE NECK SIZE UNLESS OTHERWISE NOTED. THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA 1 FAN COIL UNIT PIPING - TWO PIPE NO SCALE 2 FAN COIL UNIT CONTROL - LINE VOLTAGE NO SCALE FIE1302 OCTOBER 28, 2013 THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N 1ST FLOOR DEMOLITION PLAN - MECHANICAL HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR GENERAL PLUMBING NOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FAMILY ROOM FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N UNDERFLOOR PLAN - PLUMBING HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR GENERAL PLUMBING NOTES KEYNOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV JAN/MECH VESTIBULE VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FAMILY ROOM FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N 1ST FLOOR PLAN - PLUMBING HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR PLUMBING FIXTURE ROUGH-IN SCHEDULE FIXTURE DESCRIPTION DOMESTIC C.W. (NOTE 3) DOMESTIC H.W. (NOTE 3) SANITARY (NOTE 3) VENT (NOTE 3) WATER CLOSET 1" - 4" 2" (FLUSH VALVE) URINAL 3/4" - 2" 1 1/2" (FLUSH VALVE ) LAVATORY 1/2" 1/2" 1 1/4" 1 1/4" NOTE 1 & 2 SINK 1/2" 1/2" 1 1/2" 1 1/2" NOTE 1 & 2 ELECTRIC WATER COOLER 1/2" - 1 1/2" 1 1/4" NOTE 1 & 2 FLOOR DRAIN (FD-1) - - 2" 1 1/2" - FLOOR DRAIN (FD-2) - - 4" 2" - HOSE BIBB 3/4" - - - - REMARKS NOTES: 1. SANITARY RISER UP IN WALL TO FIXTURE SHALL BE A MINIMUM OF 2". 2. 1/2" CW AND HW APPLIES ONLY TO THE FINAL VERTICAL RISE-DROP TO EACH FIXTURE. BRANCH PIPING TO VERTICAL RISE-DROP SHALL BE A MINIMUM OF 3/4" INCH UNLESS NOTED OTHERWISE. 3. SIZES SHOWN ARE MINIMUMS. SIZES SHOWN ON THE DRAWING THAT ARE LARGER THAN THE SIZES LISTED IN THE SCHEDULE SHALL DICTATE THE ROUGH-IN SIZE. THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA 1 MEN'S RESTROOM SAN / VENT RISER NO SCALE 2 WOMENS RESTROOM SAN / VENT RISER NO SCALE FIE1302 OCTOBER 28, 2013 2 , / 1 0 - , . # & & & ( ) + " * ( % # ( # ) ( ' & % $ # " ! GENERAL PLUMBING NOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N UNDERFLOOR DEMOLITION PLAN - PLUMBING HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR GENERAL NOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N 1ST FLOOR DEMOLITION PLAN - PLUMBING HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR FIRE SPRINKLER USAGE SCHEDULE SPRINKLER AREA TYPE (NOTE 1 & 5) AREA HAZARD SYMBOL (NOTES 3 & 4) TYPE RESPONSE FINISH TEMPERATURE °F FINISHED SPACES SEE PLANS SPR-1 CONCEALED QUICK WHITE 155 MANUFACTURER & MODEL REMARKS VIKING VK, RELIABLE G4A, TYCO RFII, VICTAULIC V3802 NOTE 2 NOTES: 1. SEE FLOOR PLANS FOR ZONING REQUIREMENTS. 2. ALL SPRINKLERS SHALL BE UL LISTED. 3. CONTRACTOR TO VERIFY SPRINKLER REQUIREMENTS BASED ON ACTUAL INSTALLATION, USAGE, ARCHITECTURAL CEILING PLAN AND NFPA 13 REQUIREMENTS. 4. SYMBOL IS PRIMARILY FOR IDENTIFYING SPRINKLERS IN SUBMITTALS. IT MAY OR MAY NOT BE FOUND ELSEWHERE ON THE DRAWINGS. CONTRACTOR TO SUBMIT ALL SPRINKLER TYPES TO BE USED. 5. AREAS ARE GENERAL IN NATURE. CONTRACTOR TO MATCH UNSCHEDULED AREAS TO SIMILAR SPACES. THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FAMILY ROOM FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N 1ST FLOOR PLAN - FIRE PROTECTION HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR GENERAL NOTES THE EASTERN IOWA AIRPORT TERMINAL BUILDING IMPROVEMENTS LANDSIDE PRE-SECURITY RESTROOM REMODEL CEDAR RAPIDS, IOWA ELEV VESTIBULE JAN/MECH VESTIBULE STORAGE INFO MEN'S WOMEN'S CONCESSIONS FIE1302 OCTOBER 28, 2013 VENDING FAMILY RR 1 N 1ST FLOOR DEMOLITION PLAN - FIRE PROTECTION HALL SCALE: 1/8"=1'-0" O R T H KEYPLAN WOMENS RR