Surface Mount: F = Ceiling / R = Wall / O = Bottom Installation Drawing Applicable luminaires: A 1 | A4 | ACL2 | A CL3 | ACL4 | B4 | D2 | D3 | D4 | E2 | E3 | E4 | G3 | G4 | O2 | O3 | X6 A B Rows: 1. A 1 lens 2 2 1. When rows are ordered: row sections will be labeled in sequence. Position sections in proper order prior to installation. (ie: Place 1 next to 1). 2. Connect wiring between housings using the provided quick connects. 2. 3. Line up pins and bang extrusion pieces together using a mallet until no gap remains. 4 1 1 3 C 4. Secure extrusions with joiner brackets using a threaded rod or bolt with flange nuts (provided). D Gyp Ceilings: 1. Drill mounting and powerfeed holes in top or side of extrusion, near each end. Be cautious of internal components. Secure fixture to studs at a minimum of two locations per extrusion, with appropriate hardware (by others). DRILL HERE (CEILING OR BOTTOM) GEAR TRAY DRIVER DRILL HERE (WALL) REFLECTOR 1 1. Reinstall LED or fluorescent gear tray and lamps, if applicable (by others). * Do not rely on bare sheetrock for fixture support. Always tie to structure. Powerfeed: LENS D3 LED Fixture Shown 2 1. Route power wires through pre-drilled holes or drill holes in top or side of extrusion (refer to Powerfeed Location chart on page 2). Fixture housing can be used as a J-box. Wire per code. 2. Reinstall louver or lens. Lens may have optical inserts. Louver or Lens D3 LED Fixture Shown IDS Caddy Clip Option ATTENTION: IDS Caddy with stud attached (by others), surrounding T-Bar. Ceiling Tile Mounting Nut (by others-typically packaged with the IDS Caddy) Close-up of our housing top attached to tile ceiling. *CONSULT LOCAL BUILDING CODE AUTHORITIES FOR INSTALLATION REQUIREMENTS AND APPROVALS. IDS CADDY T-bar Ceilings: *WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FLUORESCENT LIGHTING ELECTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN. 1. Drill mounting and powerfeed holes in top of extrusion, being cautious of internal components. Attach IDS Caddy Clips (by others) around T-bar. *WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE BALLAST WIRE, OR OTHER ELECTRICAL COMPONENTS MAY BE DAMAGED WHEN DRILLING FOR INSTALLATION OF FIXTURE TO WALL OR CEILING. CHECK FOR ENCLOSED WIRE AND COMPONENTS. 2. Lift fixture into place and fasten the Caddy Clips’ threaded bolt through housing. *WARNING: TO PREVENT WIRE DAMAGE OR ABRASION, DO NOT EXPOSE WIRES TO EDGES OF SHEET METAL OR OTHER SHARP OBJECT. DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRE OR ELECTRIC COMPONENT DURING FIXTURE INSTALLATION. 3728 maritime way oceans ide , ca 92056 p. 760.727.7675 f. 760.727.7695 a· light | Jan 2015 / O = Bottom Surface Mount: F = Ceiling / R = Wall Installation Drawing Applicable luminaires: A 1 | A4 | ACL2 | A CL3 | ACL4 | B4 | D2 | D3 | D4 | E2 | E3 | E4 | G3 | G4 | O2 | O3 | X6 Powerfeed Locations: Ceiling or Bottom Mount Use pre-drilled powerfeed holes or drill at the following recommended locations : 1-3/8 TOP VIEW (OR BOTTOM VIEW FOR BOTTOM MOUNT) TOP VIEW (OR BOTTOM VIEW FOR BOTTOM MOUNT) ACL3 | ACL4 | B4 | D3 | D4 | G3 | G4 | O3 | X6 TOP VIEW E3 | E4 Applicable Luminaires Ceiling/Surface Mount (Downlight) A1 ACL3 D3 G3 E3 X6 O2/O3 (Pre-drilled holes) Bottom Mount (Uplight) B4 ACL4 G4 D4 E4 Powerfeed Locations: Wall Mount Use pre-drilled powerfeed holes or drill at the recommended locations for each fixture type shown below (measured from bottom of fixture) : Applicable Luminaires Wall Mount (Up/Downlight) 4.000 1.500 1.375 1.000 A4 ACL2 ACL3 1.750 1.000 1.000 ACL4 D2 B4 D3 LED Fixture Lengths 3.750 1.250 E2 D4 E3 G3 E4 3.500 2.500 2.500 ACL2 | ACL3 | ACL4 | B4 | D2 D3 | D4 | E2 | E3 | E4 | G3 | G4 | O3 | X6 3.125 2.250 G4 O3 Notes Always consult submittal drawings (if applicable) for the most accurate dimensions and powerfeed locations. Drivers and ballasts are typically located towards the center of each extrusion. Be aware of driver/ballast locations before drilling any holes. Factory-drilled powerfeed holes will be drilled and tapped for 1/2" chase nipple. changing the right to make design or options wit ts tice NOMINAL LENGTH LIGHTED LENGTH OVERALL LENGTH 2 3 23.00 34.50 23.75 35.25 46.00 46.75 5 6 57.25 58.00 69.00 69.75 7 8 80.25 81.00 9 91.75 102.75 92.50 103.50 10 11 12 114.75 126.00 143.25 115.50 126.75 144.00