R L509 816 PBX INTERFACE (ANALOG) CALL 1-800-999-3600 146 3 57 ( 214" ) DI M ENSI ONS I N MI LLI M ETRES Power I nUse Mode Vi deo 816 PBX I NTERFACE ( DI M ENSI ONS I N FEETI NCHES) (5 4") 816 PBX INTERFACE 3 86 PERSPECTIVE VIEW ( 3 8" ) THI RD ANGLE PROJECTI ON TOP VIEW PROGRAMMING OPTIONS **11 xxx Select xxx as value for mic level 000-255 **50 x 171 172 **10 xxx Select xxx as value for speaker level 000-255 ( 61116" ) Open video connection to lane from operator xx ( 634" ) **0 xx select x as ring cadence (0 for Standard or 1 for Distinct) PAGE 1 OF 3 0 = 250 ms ; 1 = 500 ms; 2 = 1 secs ; 3 = 5 sec. **70 Select mode 0 (trunk port) 3 Select x as dry contact time (0-3) 86 **6 x ( 3 8" ) **51 xxx Select xxx as number of rings 000-255 146 FI LE NO.1781898 REV.1 " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" (534") FRONT VIEW Telephone port Power (Program) (Video) Call Switch SIDE VIEW Customer Audio USB (Upgrade) RJ11 TELEPHONE CONNECT TO PORT (PROGRAM) CUSTOMER STATION RJ45 VIDEO POWER USB (UPGRADE) OPTIONAL CALL CHIME BOTTOM VIEW R NOTES: 1. ONE 816 PBX INTERFACE IS REQUIRED FOR EACH CUSTOMER STATION (DRIVE-THRU LANE). 2. ONE EXTERNAL CALL CHIME SUPPORTS UP TO TWO CUSTOMER STATIONS WITH DISTINCT TONES. 3. DIAGNOSTIC TELEPHONE SHOULD BE LOCATED IN OPERATORS KNEE SPACE AREA SPECIFICATIONS POWER ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES VOLTAGE 22VDC MIN. 27VDC MAX CURRENT 50mA MIN. 200mA MAX CONTACT RATING 24VDC 1A DIMENSIONS 171mm (634") H. X 146mm (534") W. X 57mm (214") D. TRUNK PORT 0 CALL ORIGINATION: (25 ma DC CURRENT LOOP PROVIDED ON CALL ANSWER) GENERATE 90V 20Hz SINE WAVE FOR 3 REN TO TELEPHONE SYSTEM (PROGRAMMABLE RING CADENCE) TELEPHONE USER ACCESSES PBX INTERFACE BY USE OF A TRUNK KEY. (TELEPHONE SYSTEM DEPENDANT) ACCESS CAN BE ACHIEVED BY PROGRAMMING AN ACCESS CODE FOR A SPECIFIC TRUNK LINE. (TELEPHONE SYSTEM DEPENDENT) 0 CALL TERMINATION BY HANGING UP TELEPHONE. 0 TRUNK PORT IS UNBALANCED (LESS THAN A 350 METERS (1000’-0") CONNECTION OVER INTERNAL WIRING) 0 NOT INTENDED FOR NETWORK CONNECTION OR USE OVER EXPOSED PLANT 0 CONNECTION OF TRUNK PORT TO ANALOG STATION PORT OF TELEPHONE SYSTEM SHALL NOT CAUSE DAMAGE TO THE 816 PBX INTERFACE. THI RD ANGLE PROJECTI ON 816 PBX INTERFACE KIT INCLUDES (41-017478-000-A) 0 816 PBX INTERFACE UNIT (41-017476-000A) 0 RJ-1 1 CABLE 0 CALL CHIME CABLE (AUDIO) (19-042364-000A) 0 POWER RJ-45 CABLE (31-020363-000A) 0 GENDER CHANGER (29-012934-000A) 146 10 (534") 3 (8") 10 3 ( 8") 126 NOTE: (5") MOUNTING ANCHORS AS REQUIRED 86 ( 338" ) 816 PBX INTERFACE 86 PER SITE CONDITIONS (BY OTHERS) ( 338" ) PAGE 2 OF 3 TYPICAL MOUNTING PROGRAMMING OPTIONS 172 ( 634" ) " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" FI LE NO.1781898 REV.1 **11 xxx Select xxx as value for mic level 000-255 **50 x 152 Open video connection to lane from operator xx ( 6" ) CLEARANCE **0 xx **10 xxx Select xxx as value for speaker level 000-255 select x as ring cadence (0 for Standard or 1 for Distinct) **51 xxx Select xxx as number of rings 000-255 **6 x Select x as dry contact time (0-3) 0 = 250 ms ; 1 = 500 ms; 2 = 1 secs ; 3 = 5 sec. **70 Select mode 0 (trunk port) PERSPECTIVE VIEW FRONT VIEW R 816 PBX INTERFACE CALL 1-800-999-3600 TYPICAL SCHEMATIC A ELECTRICAL CONTRACTOR TO PROVIDE (1) DUPLEX OUTLET AT EACH A LOCATE IN OPERATORS KNEE SPACE AREA. * ON (1) 120 VAC, 60 Hz., 10, / (3W), 20 AMP DEDICATED BRANCH CIRCUIT. THE RECOMMENDED LOCATION FOR THE CALL CHIME IS IN THE OPERATORS KNEE SPACE AREA OR WITHIN INTERFACE UNIT. ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES LOCATE WITHIN 1829mm (6’-0") TO 2438mm (8"-0") OF THE 816 PBX B 15.24 METERS (50’-0") OF THE PHONE INTERFACE. ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT B TO BUILDINGS ELECTRICAL SUPPLY PANEL. AUDIO CABLE #20 AWG, 6 CONDUCTOR, 3 TWISTED PAIR, INDIVIDUAL FOIL SHIELD WITH DRAIN, COLOR CODED ( BELDEN #9873 OR EQUIVALENT ) RJ-11 CABLE 1219mm (4’-0") MAX. LENGTH A PLUG-IN TRANSFORMER * AUDIO CCA B POWER DIEBOLD THI RD ANGLE PROJECTI ON RJ-45 CABLE 11-040335-000-A (31-020363-000A) 816 PBX INTERFACE PROGRAMMING OPTIONS **0 xx Open video connection to lane from operator xx **10 xxx Select xxx as value for speaker level 000-255 **11 xxx Select xxx as value for mic level 000-255 **50 x select x as ring cadence (0 for Standard or 1 for Distinct) * **51 xxx Select xxx as number of rings 000-255 **6 x SUPPLIED BY CUSTOMER Select x as dry contact time (0-3) 0 = 250 ms ; 1 = 500 ms; 2 = 1 secs ; 3 = 5 sec. **70 Select mode 0 (trunk port) CUSTOMER STATION #2 816 PBX INTERFACE 3 PAIR MPR/CMR, 24 AWG LEVEL 2 CALL SWITCH CABLE OR EQUIVALENT (19-042364-000A) PRIVATE BRANCH EXCHANGE PAGE 3 OF 3 PLUG-IN STEP DOWN A TRUNK 120 V, 16.5 VAC (31-017885-000A) PORT RJ-11 CABLE TRANSFORMER * RJ-11 (6) CONDUCTOR PHONE JACK B #20 AWG, 2 CONDUCTOR, TWISTED, FOIL SHIELD (91-020023-6262) * (BELDEN 9154 OR EQUIVALENT) RJ-11 CABLE " ALL DI M ENSI ONS AND DESI GN CRI TERI A SUBJECT TO CHANGE W I THOUT NOTI CE" EXTERNAL CALL CHIME (OPTIONAL) AUDIO CABLE (31-020173-000A) 4572mm (15’-0") MAX. LENGTH (31-020277-000-A) #20 AWG, 2 CONDUCTOR, TWISTED, FOIL SHIELD (91-020023-6262) PHARMACIST PHARMACIST PHONE #1 PHONE #2 (BELDEN 9154 OR EQUIVALENT) CALL SWITCH CABLE (19-042364-000A) CUSTOMER STATION #1 RJ-11 CABLE GENDER CHANGER 1219mm (4’-0") (29-012934-000A) MAX. LENGTH 816 PBX INTERFACE PROGRAMMING OPTIONS **0 xx Open video connection to lane from operator xx FI LE NO.1781898 REV.1 **10 xxx Select xxx as value for speaker level 000-255 **11 xxx Select xxx as value for mic level 000-255 **50 x select x as ring cadence (0 for Standard or 1 for Distinct) **51 xxx Select xxx as number of rings 000-255 **6 x **70 PLUG-IN * Select x as dry contact time (0-3) 0 = 250 ms ; 1 = 500 ms; 2 = 1 secs ; 3 = 5 sec. A TRANSFORMER Select mode 0 (trunk port) 816 PBX INTERFACE B POWER RJ-45 CABLE (31-020363-000A) *