THE NEW PANASONIC SOLUTION FOR CHILLED AND HOT WATER PRODUCTION! FROM 28 kW TO 80 kW Key beneļ¬ts: · No cascade installation up to 80 kW with GHP outdoor unit and 51.3 kW with ECOi · No Glycol needed when WHE is located on the heated part of the building · Full line-up of outdoor units which can cover up to 80 kW heat demand · Large choice of remote controls and interfaces · 3.25 COP with water at 45 °C and outdoor temperature of +7 °C Energy saving Environmentally friendly refrigerant R410A 94 High savings Environmentally friendly refrigerant R410A VRF SYSTEMS With ECOi outdoor units With GHP outdoor units: · Maximum hot water outlet temperature: 45 °C · Minimum chilled water outlet temperature: 7 °C · Outdoor temperature range in cooling mode: +5 °C to +43 °C · Outdoor temperature range in heating mode: -20 °C to +15 °C · Hot water outlet temperatures from 35 °C to 55 °C · Chilled water outlet temperatures from 5 °C to 15 °C · Outdoor temperature range in cooling mode: -10 °C to +43 °C · Minimum outdoor temperature in heating mode: -21 °C ECOi Water Heat Exchanger ECO G Water Heat Exchanger. Mixed System Application Electrical VRF with Water Heat Exchanger · With this easy to install Water Heat Exchanger unit, you can now cover projects up to 51 kW hot water demand or 44 kW on chilled application on a efficient way and cost effective. · Combined with a Water Heat Exchanger unit, the Panasonic GHP can create a flexible system, the ideal replacement for existing chiller and boiler systems. · The GHP Multi System can have an indoor unit plus a GHP chiller. When the two systems are operated independently, an outdoor unit with 130% capacity can be connected. SYSTEM EXAMPLE SYSTEM EXAMPLE Floor Heating Floor Heating Fan Coil Unit ECO G Chiller Water Heat Exchanger Fan Coil Unit ECOi Chiller Water Heat Exchanger Buffer Tank Refrigerant piping Duct* Refrigerant piping Air Handling Unit Note: The mode of running of outdoor unit depends on the Water Heat Exchanger’s mode. The water pump is not included in the Water Heat Exchanger unit. For simultaneous operation, however, the maximum capacity is 130%. Please inquire details of this system design of Panasonic. * Standard DX type indoor unit system. MODEL Rated capacity Cooling/Heating Rated power input Cooling/Heating Rated current Power supply Water volume flow Pressure loss Water volume in heat exchanger / in primary circuit (min) Max. water pressure Type of anti-freeze protection Dimensions / Weight HxWxD Pipe connections Gas pipe / Liquid pipe Max. piping length Max. height difference IU above OU / OU above IU Power supply wire diameter Communication wire (LIYCY) Fuse size (slow-blow) Duct* Water Piping Air Handling Unit Outdoor unit Water Piping Outdoor unit Buffer Tank kW kW A V / Ph / Hz m³/h kPa m³ MPa mm / kg mm m m mm² mm² A Control wiring Note: The mode of running of outdoor unit depends on the Water Heat Exchanger’s mode. The water pump is not included in the Water Heat Exchanger unit. For simultaneous operation, however, the maximum capacity is 130%. Please inquire details of this system design of Panasonic. * Standard DX type indoor unit system. S-250WX2E5¹ S-500WX2E5 S-710WX2E5² 25 / 30 0.01 0.07 220-240 / 1 / 50 4.3 6.6 0.008 / 0.28 0.686 Flow switch 1,000 x 395 x 965 / 110 22.22 / 9.52 170³ 35³ 5 / 50³ 2 x 2.0 2 x 0.5~2.0 (total length up to 1,000 m) 15 50 / 60 0.01 0.07 220-240 / 1 / 50 8.6 9.6 0.012 / 0.5 0.686 71 / 80 0.01 0.07 220-240 / 1 / 50 12.24 11.7 0.017 / 0.73 0.686 1,000 x 395 x 965 / 130 28.58 / 15.88 170³ 35³ 5 / 50³ 2 x 2.0 2 x 0.5~2.0 (total length up to 1,000 m) 15 1,000 x 395 x 965 / 150 31.75 / 19.05 170³ 35³ 5 / 50³ 2 x 2.0 2 x 0.5~2.0 (total length up to 1,000 m) 15 1. Only with indoors combination. Can not be used as 1 to 1. 2. Only connectable with GHP. 3. Not valid in case of mixed systems, combination ratio in case of mixed systems: 50 to 130 %, combination ratio in case of one-to-one-systems: 100 %. 4. Water circulating pump. Power supply: 230 V / 1 Ph / 50 Hz; power input: 0.75 kW; external pressure head: 6 m. 5. For cooling operation where the outdoor air temperature is 10 °C or less, this value should be 30 m. 95 saving NEW ECOi 2-PIPE WITH WATER HEAT EXCHANGER FOR CHILLED AND HOT WATER PRODUCTION saving FOR HYDRONIC APPLICATIONS New Water Heat Exchanger for GHP and ECOi, dimensions reduced by 45 %. Operation and control by wired remote control CZ-RTC2. Energy-efficient capacity control. Stainless steel plate heat exchanger with anti-freeze protection control. Change-over between heating and cooling operation Energy Energy TECHNICAL ZOOM · MAXIMUM DISTANCE BETWEEN OUTDOOR UNIT AND WATER HEAT EXCHANGER: 170 m Environmentally friendly refrigerant · MAXIMUM HOT WATER OUTLET TEMPERATURE: 45 °C R410A · MINIMUM CHILLED WATER OUTLET TEMPERATURE: 7 °C · OUTDOOR TEMP. RANGE IN COOLING MODE: +5 °C TO +43 °C · OUTDOOR TEMP. RANGE IN HEATING MODE: -20 °C TO +15 °C WATER HEAT EXCHANGER S-250WX2E5* S-500WX2E5 Nominal Cooling Capacity Nominal Heating Capacity Heating Capacity at +7°C, heating water temperature at 45 °C COP at +7°C with heating water temperature at 45 °C Dimensions / Weight HxWxD Water pipe connector Pump Heating water flow (6T=5 K. 35 °C) Capacity of integrated electric heater Input Power Maximum Current 25.0 28.0 28.0 3.25 1,000 x 395 x 965 / 165 Rp2 Nut thread (50A) (Field supply) 4.3 (Not equipped) 0.01 0.07 50.0 51.3 51.3 3.10 1,000 x 395 x 965 / 190 Rp2 Nut thread (50A) (Field supply) 8.6 (Not equipped) 0.01 0.07 U-10ME1E81 U-20ME1E81 59 / 73.5 1,758 x 770 x 930 / 283 22.22 / 9.52 6.3 *Need Additional charge at site max. 170 7.5 0< Reffer to Manual 50 (OD above) 35 (OD below) -20 — 15 35 — 45 63 / 77.5 1,758 x 1,540 x 930 / 423 28.58 / 15.88 9.0 *Need Additional charge at site max. 170 7.5 0< Reffer to Manual 50 (OD above) 35 (OD below) -20 — 15 35 — 45 kW mm / kg l/min kW kW A OUTDOOR UNIT Sound pressure / Sound power level Dimensions Weight HxWxD Pipe Diameter Liquid / Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D Hight Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) dB(A) / dB mm / kg mm (Inch) kg m m m g/m m °C °C All values shown as tentative data. Performance calculation in agreement with Eurovent. Sound pressure measured at 1 m from the outdoor unit and at 1.5-m height. * Only with indoors combination. Can not be used as 1 to 1. Rating Conditions: Cooling Indoor 27 ºC DB / 19 ºC WB. Cooling Outdoor 35 ºC DB / 24 ºC WB. Heating Indoor 20 ºC DB. Cooling Outdoor 7 ºC DB / 6 ºC WB. DB: Dry Bulb; WB: Wet Bulb 96 VRF SYSTEMS Newly Slim & Light design Due to the unit’s internal redesign, the width and weight are drastically reduced. 50 mm or over 50 mm or over Standard system example 50 mm or over INSTALLATION SPACE 1615 mm 900 mm Water Heat Exchanger % REDUCTION Water Piping Outdoor unit 600 mm or over 1615 mm 45 600 mm or over 300 mm or over Refrigerant Piping 495 mm 4-Ø24 (for anchor holes) 50 at least 312 (anchor hole pitch) TOP VIEW 1014 (anchor hole pitch) at least REAR VIEW LEFT SIDE VIEW FRONT VIEW 50 at least 50 395 (external cladding) 965 (external cladding) 1000 Liquid pipe (brazed) 2000 at least Connecting cable openings 600 Transmitter box at least Hot/cold water inlet (Rp2 female thread) (50 A) 126 145 69 519 Ø19.05 (710WX2E5) Ø15.88 (500WX2E5) Ø 9.52 (250WX2E5) Gas pipe (brazed) 4-Ø30 Ø31.75 (710WX2E5) Ø28.58 (500WX2E5) Ø22.22 (250WX2E5) 1006 (suspension holes pitch) 140 1060 (frame width) 208.5 Drain opening (R1 male thread) (25 A) 272 suspension holes 417 (frame width) Hot/cold water inlet (Rp2 female thread) (50 A) 97 savings NEW ECO G WITH WATER HEAT EXCHANGER FOR CHILLED AND HOT WATER PRODUCTION savings FOR HYDRONIC APPLICATIONS New Water Heat Exchanger, dimensions reduced by 45 % (250 W x 2 and 500 W x 2). Operation and control by wired remote control CZ-RTC2. Energy-efficient capacity control. Stainless steel plate heat exchanger with anti-freeze protection control. Change-over between heating and cooling operation. High High TECHNICAL ZOOM · MAXIMUM DISTANCE BETWEEN O_U AND WHE: 170 m Environmentally friendly · POSSIBILITY TO MIX DX AND WATER HEAT EXCHANGER SYSTEMS refrigerant · NO COOLING TOWER NECESSARY R410A · HOT WATER OUTLET TEMPERATURES FROM 35 °C TO 55 °C · CHILLED WATER OUTLET TEMPERATURES FROM 5 °C TO 15 °C · OUTDOOR TEMP. RANGE IN COOLING MODE: -10 °C TO +43 °C · MINIMUM OUTDOOR TEMPERATURE IN HEATING MODE: -21 °C WATER HEAT EXCHANGER S-250WX2E5* S-500WX2E5 S-710WX2E5 Nominal Heating Capacity Heating Capacity at +7 °C, heating water temperature at 35 °C COP at +7 °C with heating water temperature at 35 °C Heating Capacity at +7 °C, heating water temperature at 45 °C COP at +7 °C with heating water temperature at 45 °C Heating Capacity at -7 °C, heating water temperature at 35 °C COP at -7 °C, heating water temperature at 35 °C Heating Capacity at -15 °C, heating water temperature at 35 °C COP at -15 °C with heating water temperature at 35 °C Nominal Cooling Capacity Cooling capacity at +35 °C, outlet tp 7 °C, inlet tp 12 °C EER at +35 °C, outlet tp 7 °C, inlet tp 12 °C Dimensions / Weight HxWxD Water pipe connector Pump Heating water flow (6T=5 K. 35 °C) Capacity of integrated electric heater Input Power Maximum Current 30 1,000 x 395 x 965 / 110 Rp2 Nut thread (50A) (Field supply) 4.3 (Not equipped) 0.01 0.07 60 62 1.49 60 1.30 57.2 0.76 59.2 0.75 50 50 1.15 1,000 x 395 x 965 / 130 Rp2 Nut thread (50A) (Field supply) 8.6 (Not equipped) 0.01 0.07 80 82,8 1.34 80 1.17 74.6 0.77 77.4 0.76 71 71 1.05 1,000 x 395 x 965 / 150 Rp2 Nut thread (50A) (Field supply) 12.2 (Not equipped) 0.01 0.07 - U-20GE2E5 U-30GE2E5 58 / 83 2,273 x 1,650 x 1,000 / 780 28.58 / 15.88 11.5 *Need additional chatge at site max. 170 7 0< Refer to Manual 50 (OD above) 35 (OD below) -21 — 15.5 35 — 55 63 / 86 2,273 x 2,026 x 1,000 / 840 31.75 / 19.05 11.5 *Need additional chatge at site max. 170 7 0< Refer to Manual 50 (OD above) 35 (OD below) -21 — 15.5 35 — 55 OUTDOOR UNIT Sound pressure / Sound power level Dimensions / Weight HxWxD Pipe Diameter Liquid / Gas Refrigerant (R410A) Pipe Length Range Pipe Length for nominal capacity Pipe Length for additional gas Additional Gas Amount (R410A) I/D&O/D High Difference Operation Range Outdoor Ambient Water Outlet (at-2/-7/-15) 2) kW kW 30 kW kW 25 kW mm / kg l/min kW kW A dB(A) / dB mm / kg mm (Inch) kg m m m g/m m 50 (OD above) 35 (OD below) °C °C All values shown as tentative data. Performance calculation in agreement with Eurovent. Sound pressure measured at 1 m from the outdoor unit and at 1.5 m height. * Only with indoors combination. Can not be used as 1 to 1. Rating Conditions: Cooling Indoor 27 ºC DB / 19 ºC WB. Cooling Outdoor 35 ºC DB / 24 ºC WB. Heating Indoor 20 ºC DB. Cooling Outdoor 7 ºC DB / 6 ºC WB. DB: Dry Bulb; WB: Wet Bulb 98 VRF SYSTEMS Combination system example The GHP multi system can have indoor units with a GHP chiller. When the two systems are operated independently, an outdoor unit with 130% capacity can be connected. Standard system example Water Heat Exchanger Water Piping Outdoor unit 4-Ø24 (for anchor holes) REAR VIEW at least 50 312 (anchor hole pitch) TOP VIEW 1014 (anchor hole pitch) FRONT VIEW LEFT SIDE VIEW at least 50 at least 50 395 (external cladding) 965 (external cladding) Transmitter box at least 600 Hot/cold water intlet (Rp2 female thread) (50A) Refrigerant piping side at least 2000 Connecting cable openings Gas pipe (brazed) Ø31.75 (710) Ø28.58 (500) Ø22.22 (250) Drain opening (R1 male thread) (25A) 126 145 69 519 1000 Liquid pipe (brazed) Ø19.05 (710) Ø15.88 (500) Ø9.52 (250) 140 208.5 272 1006 (suspension holes pitch) 1060 (frame width) Hot/cold water outlet (Rp2 female thread) (50A) 417 (frame width) 4-Ø30 (suspension holes) 99