DVS VOLTAGE STABILIZER SINGLE OR THREE PHASE 5-225KVA DVS Single or Three Phase Voltage Stabilizer 5-225kVA The DVS accommodates wide variations of incoming AC line voltage, while regulating and conditioning the AC output to preset limits. Suitable for harsh environments, the robust design utilizes a copper-wound, triple-shielded, low-impedance isolation transformer. The DVS incorporates state-of-the-art microprocessor technology and independent phase regulation engineered to eliminate voltage spikes and sags. High reliability – Exceeds 205,00 hours MTBF Low-audible noise of 65-72 dBA High efficiency – Operating at 95% efficiency at full load Transient response time of less than 2 cycles Correction time does not exceed 5 cycles Low total harmonic distortion of ≤ 1% Industrial grade – built to operate in extreme environmental conditions Designed for use with Inverter/UPS systems, or for stand-alone operations Tight AC Output regulation of ± 2% (± 1% optional) Model kVA Input Amps Input Breaker Ampacity 120 480 Output Amps 120 480 120 Heat Loss BTU/Hr Cabinet Style Weight DVS1005 5 54 14 80 16 41 711 GTD1X 447 DVS1007 7.5 810 20 100 25 63 1066 GTD1X 497 DVS1010 10 109 27 150 36 83 1422 GTD1X 569 DVS1015 15 163 41 200 50 125 2133 GTD1X 651 DVS1025 25 274 69 350 100 208 4489 GTD1X 824 DVS1030 30 329 82 420 100 250 5387 GTD1X 842 DVS1050 50 548 137 700 180 417 8979 GTD1X 1222 DVS1075 75 822 206 1000 260 625 13469 GTD1X 1287 DVS1100 100 1097 274 1350 350 833 17958 GTD2X 1960 Model kVA Output Amps Heat Loss BTU/Hr Cabinet Style Weight Input Amps Input Breaker Ampacity 208 480 208 480 208 36 16 50 20 28 1422 GTD1X 572 676 3DVS1010 10 3DVS1015 15 54 24 80 30 42 2133 GTD1X 3DVS1030 30 109 47 150 60 83 4265 GTD1X 936 3DVS1045 45 163 71 200 100 125 6398 GTD1X 1235 3DVS1075 75 274 119 350 160 208 13468 GTD2X 1430 3DVS1112 112 410 178 500 250 311 20113 GTD2X 2366 3DVS1225 225 820 356 1000 500 622 40226 GTD2X 4290 General Specifications Isolimiter Mechanical AC Input Cooling Aided Convection or Forced Air, depending on kVA rating and design (fans standard for 75kVA units and above) Nominal Voltage 120,208, 380, 415, 480, 600 VAC Cable Entry Top or Bottom Entry Standard Input Range + 10% to -15% Cabinet Rating NEMA 1 / IP-20 (IP-21 with addition optional drip shield) Frequency 50 or 60Hz ± 3Hz Optional Features (Option #) (65) (64) (105) (93) (127) (70) Drip Shield Vermin Screen Lifting Eye Bolts Padlockable Circuit Breakers PCB Confrormal Coating Fungus and Moisture Proof AC Output kVA Ratings 5-225 kVA AC Output Voltage1 120, 208, 220 Single Phase 120/208, 277/480, 220/380, 250/415 Three Phase Metering and System Measurements Regulation ± 2 % (± 1% Optional) Voltage Adjustment ± 10 % Frequency 50 or 60 Hz; + 0.1% Total Harmonic Distortion (THD) ≤ 1% AC Input Voltage AC Output Voltage AC Output Frequency AC Input Current AC Output Current Load PF 0.6 leading/lagging Transient Response Time < 2 cycles typical Correction Time < 5 cycles Overload Capacity 200% for 30 Seconds, 1000% for 1 cycle Voltage Deviation Efficiency Mechanical Alarm (Option #) ≤ 2.5% (when stepping from no load to full load) Alarm (Option #) ≥ 95% Fan Failure Low AC Output High AC Output AC Output Overload Over Temperature Applicable Standards, Codes and Regulations All alarms have options for front panel LEDs and Relays All alarms have options for front panel LEDs and Relays Environmental (120) (8) (9) (40) (10) Standard Relays Ambient Temperature 0 to 40oC (32 to 104oF) Relative Humidity 0-95% non-condensing Operating Altitude 0-3300 meters (10,000 feet) Audible Noise 65-72dB(A) @1.5 meter typical Mean Time Between Failure (MTBF) (20) (80) (81) (66) (79) AC Input (14kAIC, minimum) Battery Input (10kAIC, minimum) Bypass Input (14kAIC, minimum) NEMA PE-1 ANSI ANSI/NFPA 70 IEEE IEC UL (CUL) Listed to 1012 Unit Manufactured in ISO9001 Certified Facility 2 (Option #) Common Alarm >205,000 Hours Style H x W x D (inches) H x W x D (mm) GTD1X 79 x 32 x 36 2007 x 813 x 914 GTD2X 79 x 54 x 36 2007 x 1372 x 914 Custom Input and Output Voltages available - Consult Factory 1 Addition of drip shield may increase noise by 1-3dBA 2 Specifications subject to change without notice T H E PURPO SE OF OUR BUSINESS IS T O PROVI D E CONT I NU I T Y OF E L E CT RI CA L P O W ER TO KEEP BU SI N E SSE S I N BU SI N E SS. All Facilities are ISO 9001 Certified World Headquarters Asia Pacific Headquarters Middle East Offices India Headquarters 875 Dearborn Drive Columbus, Ohio 43085 Phone: +1-614-846-7500 Toll Free: +1-800-635-7300 Fax: +1-614-885-3990 AMETEK Singapore Office 43 Changi South Ave. 2 #04-01 Singapore 486164 Phone: +65-6484-2388 Fax: +65-6481-6588 Mexico Headquarters Brazil Headquarters Dubai P.O.Box 337164 Office 2004 , X2 Building Jumeirah Lakes Towers JLT Dubai – UAE Phone: +971544300331 Avenida Ejercito Nacional Number 423 2o. Colonia Granada C.P. 11520 Miguel Hidalgo, Mexico, D.F. Phone: +52-55-5250-1132 Fax: +52-55-5250-7981 AMETEK do Brasil Ltda Rod. Eng° Ermênio de Oliveira Penteado (SP75) - Km 57, Barrio Tombadouro Indaiatuba - SP - Brasil, 13337-300 Phone: +55-16-2107-4100 AMETEK Instruments India Private Limited Plot 148, EPIP Zone Phase 2 Featherlite Tech Park, 1st Floor Whitefield, Bangalore - 560066 Karnataka, INDIA Phone: +91 70222 53258 Fax: +91 80 6782 3232 Saudi Arabia King Khalid Street, ATCO Building Dammam, Saudi Arabia Phone: +966 13 833 2339 ext. 654 Direct: +966 830 5482 Cell: +966 55 888 7860 VISIT OUR WEBSITES: English: www.solidstatecontrolsinc.com Russian: www.solidstatecontrolsinc-ru.com Nuclear: www.nuclearups.com Chinese: www.solidstatecontrolsinc-chn.com Spanish: www.solidstatecontrolsinc-esp.com Brazilian Portuguese: www.solidstatecontrolsinc-bz.com