Micro-S Pro/ Micro-S RM Pro Micro-S RM Pro (800VA) (800 VA - 5000 VA) Micro-S RM Pro (1100 - 2200 VA) Micro-S RM-Pro (3300VA) Micro-S 1000 Pro Micro-S 5000 Tower/ RM convertible Features • pure sine wave • „long-life“ batteries • Smart backup time estimation • Adjustable voltage sensitivity, voltagetransfer points & charging voltage • Generator compatible • Automatic restart of load after UPS shutdown • Smart AVR function (Two buck / boost modes) • Cold-start capable • Audible alarm • Hot-swappable batteries for rack models • Smart battery management • Network manageable (SNMP optional) • Full function of LCD display (LED display optional) • Intelligent double stages of charging control • Power Management Software inclusive Micro-S 5000 RM/Tower convertible Applications: • Networkserver • Small computersystems • Data centers • Telecommunicationssystems • Industrial applications • Safty and protection system Micro-S Pro/ Micro-S RM Pro Model (Tower version) Micro-S 1000 Pro 1000 VA/ 600 W Micro-S 1100 RM-Pro 1100 VA/ 660 W Capacity, Power Levels (VA/W) Output Voltage Voltage waveform Crest factor Frequency (synchronized to mains) Regulation (nominal) Regulation (battery mode) Transfer time Over current protection Input Nominal Voltage Frequency Efficiency (normal mode) Noise filtering Over current protection 230V Over current protection 115V Voltage range AVR range (2 bucks, 2 boosts) Surge protection 230V models Surge protection 115V models Battery Type Capacity Tower Capacity 19"RM Voltage in Vdc Backup time half-load Charging method Charging time Average charging current Average charging voltage for each battery Protection Monitoring Micro-S 800 RM-Pro 800 VA/ 480 W Micro-S 5000 5000 VA/ 3750 W Micro-S 5000 RM 5000 VA/ 3750 W 100/110/115/120 V or 200/220/230/240 V selectable 47Hz ~ 65Hz, 50/60Hz auto-sensing 97% full time EMI/RFI filtering by AC fuse by re-settable over current protector by AC fuse by re-settable over current protector ´-20% ~ +24% for selected nominal voltage; -29% ~ +33% adjustable by using the remote set-up software enhanced buck: +15% of selected nominal voltage; buck mode: +5% of selected nominal voltage boost mode: -5% of selected nominal voltage; enhanced boost: -12.5% of selected nominal voltage 220 Joules 440 Joules 660 Joules 216 Joules 324 Joules maintenance-free sealed, valve-regulated, lead-acid 12V-7Ah 12V-7Ah 12V-9Ah 12V-9Ah 12V-7Ah 6V-9Ah 12V-9Ah 12V-7Ah 12V-9Ah 12V-9Ah 12V-7Ah 18 24 36 48 72 72 (2x6 Batt.) 18 Min. 14 Min. 12 Min. smart pulse charging with two charging modes: Quick charging when battery is not fully charged; trickle charging when battery is 90% fully charged less than 3 hours to 90% at normal line and normal temperature 2.5A quick charging mode: 14V maximum trickle charging mode: 13.2V ~ 13.9V adjustable with the remote set-up software over current protection (SCR control); over charging voltage protection (SCR control); thermal protection (CPU control); When temperature inside UPS is over 45°C, charger will stop charging for 2.5 minutes followed by an 1.5 minutes charging. The cycle will be repeated until the temperature is lower than 44° C. smart monitoring&warning for failed battery or open-circuit battery. Auto-detection each time when power on or every 6 days RS232, DB9, USB, optional for RJ45 Standard interface port 19" RM Software Optional interface port Tower EBT(estimation of backuptime) Green mode function (auto-shutdown during blackout) Environmental and safety Operation temperature Transit/storage temperature Relative humidity Operating altitude Audible noise, 1M from surface Safety markings Tower Safety markings 19" RM EMC Quality control system Physical Dimensions (DxHxW) unit/shipping Tower in cm Dimension (DxHxW) unit/shipping 19" RM in cm Weight (Net/Gross kg) Tower Weight (Net/Gross kg) 19" RM Packing Micro-S 3300 Pro 3300 VA/ 2000 W Micro-S 3300 RM-Pro 3300 VA/ 2000 W 100/110/115/120 V or 200/220/230/240 V selectable sine wave 3:1 auto select for 50/60 Hz; 47Hz ~ 55Hz for 50Hz nominal; 56Hz ~ 65Hz for 60Hz nominal ±5% typical of nominal voltage (optional at ±8% AVR for wide I/P upt to ±35%) ±3% of selected output voltage (adjustable by using the remote set-up software) blackout 3ms typical; brownout 1ms typical; battery mode to normal mode: 1ms typical over load alarm level 100% ~ 120%; over load shutdown level 120% ~ 190%, (adjustable by using the remote set-up software) Communications & Management Standard interface port Tower Optional interface port 19" RM Control panel Audible alarm Micro-S 2200 Pro 2200 VA/ 1350 W Micro-S 2200 RM-Pro 2200 VA/ 1350 W RS232, DB9, USB, RJ45 optional (Surge Protection) UPSilon 2000 compatible SNMP external type 3xRS232,DB9, USB, RJ45 optional as Tower internal or external SNMP external SNMP internal oder external type LCD or LED selectable alarm on battery: low battery & battery over voltage, alarm on abnormal operation: Over load, Short-circuit & over heat support for LCD display 1% to 14% full load (adjustable by using the remote set-up software) The default setting is OFF. up to 1500 meters: 0°C to 40°C (32°F to 104°F) -15°C to 55°C (5°F to 131°F) 5 - 95% non condensing 0 ~ 3000 meters ≤ 40 dBA EN 62040, 230V-models: CE, 115V-models: BSMI; EN 62040, CE Class B, EN50091-2, FCC part15, IEC1000-2-2 ISO 9001 18x20x38 / 30x33x48 1HE x 40 18x20x45 / 30x33x54 2HE x 47 / 59x61x22.5 18x20x51 / 30x33x61 17,8x48,3x52 3HEx47/ 4HEx52 58x62x27 15/16 kg 21/22 kg 25/26 kg 36/37 kg 70/74 kg 14/16 kg 18/20 kg 23.5/25.5 kg 28/30 kg 41/43 kg 70/74 kg export carton for each unit, Tower: 16-30 / 19“ RM 14~21 units per pallet AdPoS Advanced Power Systems GmbH & Co. KG Pfaffensee 2 · D-91301 Forchheim Tel. +49 (0) 91 91 / 70 05 - 0 · Fax +49 (0) 91 91 / 70 05 - 20 info@adpos-ups.de · www.adpos-ups.de November 2012 Model (19“ RM-version) Capacity, Power Levels (VA/W) Micro-S 1500 Pro 1500 VA/ 900 W Micro-S 1650 RM-Pro 1650 VA/ 1000 W