Automatic Transfer Switches From 80A to 3200A E l e c t r i c a lI n d u s t r i a l 80 to 3200A Automatic Transfer Switch GGLD - 80 ~ 3200A/4P GGLD-3200A-4 Automatic transfer switch 80 to 3200A, motor 230VAC Conforming to IEC60947-1, IEC60947-3, IEC60947-6-1 Page 2 GGLD-80/4 GGLD - 80 ~ 3200A/4P 80 to 3200A Automatic Transfer Switch Product features Good Safety • With double-row composite contacts, lever pulling opening and closing mechanism, micro-motor energy pre-stored technology as well as microelectronic control technology, no flashover (arc chute not required) is achieved. • Adopt reliable mechanical and electrical interlock. • Due to zero crossing technology, it can be set to ‘O’ position under emergency (Both power supplies are cut off to load). • With visible indication of on-off position and padlocking function, which power supply to load is clearly visible and can be locked respectively. High reliability and service life of above 8000 times • Designed with electromechanical integration,the switch transfers accurately, flexibly and smoothly. • Supply to motors and other parts are cut-off after achieving steady state position thereby saving energy. • All logic components are of reputable brands like Philips,Motorola and Omron. • Motor used is neoprene damp-heat type, with safety device. It will trip when temperature is over 110oC or on over current. It’ll be reset automatically when fault is eliminated. We adopt spur-gear for reversible reduction gear. Superior electromagnetism compatability and Highly automated to provide 2 types of operating mode • Switch with multi-circuit input/output interface that realise remote control by external logic eg. thru PLC or hard• ware logic. Switch come with internal logic which provides stable switching. No need for external controls. Good apperance, compact size and good orientation of busbars • Compact size allows saving of switchboard space. • Good orientation of busbars allows flexibility in the connecting direction of both power supplies and load. Conformity to standards • IEC60947-6-1 for Automatic Transfer Switching Equipment. • IEC60947-1 for Low-Voltage Switchgear and Controlgear General Rules. • IEC60947-3 for Low-Voltage Switchgear, Low-Voltage Switches, Disconnectors, Switch-disconnectors and FuseSwitch combination units. GGLD D 1 (B) No of poles Order informations A(fully-automatic), S(external controlled) Rated current Ultra-thin type [ A(fully-automatic) ] Design no. Automatic transfer switches Gele Electrical Industrial Co., LTD Page 3 GGLD-80/4P 80A 4P Automatic Transfer Switch Outline & Installation Dimensions Maximum extent of handle rotating 153 14 74.5 10.5 30 30 126 30 36 244.5 145 18 7 84 106 106 φ6 2.5 2.5 86 Operating Handle 133 Main Technical Indices Conventional heating current Rated insulation voltage UI Rated impact withstand voltage Uimp Rated working voltage Ue Ratedworking current le Load characteristic Rated making capacity Rated breaking capacity Rated limiting short-circuit current Rated short time withstand current IS Change-over time (I to II, II to I) Voltage of control power supply Energy consumpution of the motor Weight Kg 20A 20A 4.2 40A 63A 750V 8KV AC440V 40A 63A AC31A, AC35A,AC33A 10Ie 8Ie 100KA 7KA 0.45 Sec AC230V 50/60Hz In-rush 300W, Normal 55W 4.3 4.4 80A 80A 4.5 Wiring Diagram Of Terminals (Without Double-Breaking) N1 C1 C2 Normal power supply 230VAC N2 Standby power supply 230VAC C N AC230V FU2 FU1 Switch’s contact output terminals wiring HD1 HL1 HL2 HD2 302 303 304 305 Note : HL1 & HL2 are power on indicators for Normal and Standby power supply respectively. HD1 & HD2 are switch’s position indicators for Normal and Standby power. FU1 & FU2 are fuses (2A); 302 to 305 are switch’s terminals. Page 4 GGLD - 80 ~ 3200A/4P 80 to 3200A 4P Automatic Transfer Switch Main technical indices Conventional heating current 80A Rated Insulation voltage Ui 750V 1000V Rated impact withstand voltage Uimp 8KV 12KV Rated working voltage Ue AC440V Rated working current Ie 380V 100A 160A 250A 400A 630A 1000A 1250A 1600A 2000A 2500A 3200A AC 21 80 100 125 160 250 400 630 1000 1250 1600 2000 2500 3200 AC 22 80 100 125 160 250 400 630 1000 1000 1250 2000 2000 2500 AC 23 80 100 125 160 250 400 400 1000 1000 1000 1250 1250 1250 Rated making capacity 10IE Rated breaking capacity 8Ie Rated short time withstand current 1sec 7KA Changeover time (I - II, II - I) 0.6 Sec Motor consumption 125A 9KA 13KA 50KA 55KA 1.2 Sec 2.4 Sec In-rush 300W 325W 355W 440W 600W Normal 55W 62W 74W 98W 120W Weight Kg 7.2 7.5 7.5 8.8 9 16.5 17 36 40 49 95 98 135 Applicable schemes M Two supplies One load • Normal supply • Standby supply • Emergency loads • One supply • Two pump loads One supply Two Loads M L1 M One supply One reversible load Multi-service One reserved control L2 • One supply • One reversible motor load L M L1 M L2 • One supply • One essential load • Two interchange load L3 Page 5 GGLD - 125 ~ 1600A/4P 125 -1600A 4P Automatic transfer switch Outline & installation dimensions J Electrical connections area Max rotation range of Handle E N G L S G Z H rad ius O φX R B1 B U K N T 145 H Z G Operating Handle T C V Y Y1 P P P A1 W Operating Handle A 40 20 φ13 18 20 φ12.5 12.5 20 35 20 40 80 1000A 1250A 1600A Dimensions Overall size Installation for switch Connecting terminals Spec A A1 B B1 C E G H J K L N O P R S T U V W X Y Y1 Z 125A 453 359 160 135 251 195 190 30 339 95 7 86 253 50 25 30 3 130 27 162 11 60.5 136.5 15 160A 453 359 160 135 251 195 190 30 339 95 7 86 253 50 25 30 3 130 27 162 11 60.5 136.5 15 250A 453 359 160 135 251 195 190 30 339 95 7 86 253 50 25 30 3.5 130 27 162 11 60.5 136.5 15 400A 525 433 260 228 319 262 190 25 413 180 9 89 324 65 40 50 5 201 37.5 180.5 13 82.5 192.5 20 630A 525 433 260 228 319 262 190 25 413 180 9 89 324 65 40 50 6 201 37.5 180.5 13 82.5 192.5 20 1000A 1007 633 330 250 370 321 470 65 609 220 11 85 524 120 63 65 8 60.5 188.5 107 249 1250A 1007 633 330 250 370 321 470 65 609 220 11 85 524 120 63 65 8 60.5 188.5 107 249 1600A 1007 633 330 250 370 321 470 65 609 220 11 85 524 120 63 65 10 60.5 188.5 107 253 Page 6 GGLD - 2000 ~ 3200A/4P 2000 - 3200A 4P Automatic transfer switch Outline & installation dimensions 2-6 6 3-7 G 8 Y3 4 1-5 2’-6’ 3’-7’ 2 6 C 468 495 Y2 4-8 8’ 4’ Y1 S 1’-5’ 6’ 78.5 4’-8’ 2’ 185 φ13 12.5 12 141.5 J O Max rotation range of handle 7-7’ 5-5’ 3-3’ 1-1’ 8-8’ 6-6’ 4-4’ 2-2’ G 2000A ius 20 rad 40 80 20 H 20 40 84.5 250 Y1 Y2 Y3 33 147 84 147 13 152 79 152 13 152 79 152 H 35 50 35 220 100 25 50 B φ13 R V 120 120 120 120 A1 A 2500A/3200A Dimensions Overall size Spec A A1 B C 2000A 1007 633 455 2500A 1007 633 455 3200A 1007 633 455 Installation for switch E K L N O Connecting terminals G H J P R S T 562 470 53 467 524 562 470 28 467 524 80 80 10 120 100 10 562 470 28 467 524 120 100 12 U V W X Page 7 GGLD - 80 ~ 3200A/4P 80-1600A 4P Automatic transfer switch Remote control wiring way SB2 Normal power supply AC230V SB1 FU1 Standby power supply AC230V FU2 HD1 HL1 201 202 203 204 205 206 101 102 103 104 105 106 SB1 : Manual normal power cut in button SB2 : Manual standby power cut in button HD2 HL2 301 302 303 304 305 306 FU1/FU2 : Fuses 2A HL1/HL2 : Normal/Standby power indicator HD1/HD2 : Switch’s position indicator Auto-manual remote control wiring way Automatic Normal power supply AC230V Manual Standby power supply AC230V SAM 1 2 3 4 SB1 FU1 FU2 HD1 SB2 HL1 101 102 103 104 105 106 301 302 303 304 305 306 201 202 203 204 205 206 SAM : Automatic/Manual function selector switch SB1 : Manual normal power cut in button SB2 : Manual standby power cut in button Page 8 HD2 HL2 FU1/FU2 : Fuses 2A HL1/HL2 : Normal/Standby power indicator HD1/HD2 : Switch’s position indicator Other products GELE also offers other products like; • On-load break switches from 40A to 3150A, 3P & 4P. • Manual changeover switches from 125A to 3150A, 3P & 4P, both break before make and make before break. • Fuse combination switches from 32A to 630A, 3P. Gele Electrical Industrial Co, LTD Page 9 Singapore Representative GTAC Singapore PTE LTD Block 4004, Depot Lane #01-01, Singapore 109758 Telephone: (65) 62731363 / 62736343 Fax: 62781126 Email: gtac@starhub.net.sg