Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April 2008 – A multinational company with 37 locations worldwide – Sensidyne is the instrumentation hub for the Americas Expanded to new manufacturing and corporate headquarters in January, 2013 Certified to ISO9001:2008 Ongoing investment in product development and sustaining engineering Sensidyne Fixed Gas Detection Committed to providing the best solutions for gas detection. Robust designs that are hazardous area and performance certified Uncompromising dedication to the highest level of quality. – Plant Is An ISO 9001:2008, EN 13485:2003 Certified Facility Gas detection options certified to SIL2 for hardware and software Predictive maintenance functions Universal instrument platforms Quality Management System structured & operated in accordance with ISO 9001:2008 Employees share responsibility to provide products with superior quality Customer satisfaction is our highest priority Providing Solutions to a Wide Range of Industries and Applications SensAlert ASI Advanced Safety Integrity for confidence in every safety application. Enhanced design to ensure reliability – – – – Third-party SIL-2 certification validating reliability Sensors are performance tested and certified Sensor Test-On-Demand, with on-board gas generator Predictive sensor failure Universal platform with Intrinsically Safe sensor head – – – – Replace sensors without area declassification or hot work permits Shop calibrate then hot-swap gas sensors in hazardous classified areas Remote mount sensor up to 100 ft./30 m. away without rigid conduit RS485 Modbus RTU & HART communication options and Standard 4-20 mA SensAlert ASI Unmatched application versatility and ease of use. Intelligent Plus Series sensors – – – – – Flexible installation or retrofit – – – – Auto-recognition and set-up from sensor memory Extensive sensor options for Flammables/Combustibles, Toxics, and Oxygen Compatible with all Plus Series sensor ranges and technologies Four records of calibration Min/Max gas and temperature readings 2-wire and 3-wire transmitter models with global performance approvals Versatile installation and operation in hazardous classified areas Non-intrusive configuration and maintenance interface Configurable alarms & warnings for hazard notification Wide-ranging application options – – Intrinsically Safe or Explosion Proof installation configurations Remote sensors and gassing, duct mount, and sample draw SensAlert ASI Global approvals – FM, CSA, ATEX, and CE Intrinsic Safety – IEC 60079-0:2006, IEC 60079-11:1999, IEC 60079-15:2007 SIL-2 Certified – – IEC 61508 SIL-2 Parts 1,2, & 3 Hardware & Software. Certified for use in SIL-2 applications. NEC and CEC Class I Div 1, Grps A, B, C, D; Class II Grps E, F, G; Class III T4 Flame Proof ATEX Directive 94/9/EC IECEx – Explosion Proof – NEC and CEC Class I Div 1, Grps A, B, C, D; Class II Grps E, F, G; Class III T4 ATEX EEx ia IIC T4 II 1 G CE Mark – ATEX EEx d[ia] IIC T4 II 2 [1] G Non-Incendive – NEC and CEC Class I Div 2, Groups A, B, C, D; Class II Grps E, F, G; Class III T4 ATEX EEx nC [ia] IIC T4 II 3 [1] G Certificate of Compliance – SIL-2 Compliance Certification for Parts 1 – 3 for General, Electrical, and Software SensAlert Plus Universal platform gas detection transmitter for safety applications. Foundation for development of SensAlert ASI Shares all features of SensAlert ASI except: ⓧ ⓧ ⓧ ⓧ ⓧ SIL2 Certification Four calibration records Menu driven contrast adjustment Rotatable enclosure options Calibration due notification SensAlarm Plus Advanced all-in-one gas monitoring system for local and remote gas detection. Complete gas detection system – Stand-alone single point AC or DC powered gas detection system – 1 or 2 double-flash strobes, horn and reset button – Optional battery back-up Application-flexible installation and easy maintenance – Non-intrusive configuration and maintenance interface – Remote sensor & gassing, duct mount, or sample draw – Mount sensor up to 100 ft./30 m. away using 4 conductor cable Shown in Dual Strobe Configuration SensAlarm Plus Convenience and performance in a single easy to use and install package. Intelligent Plus Series sensors for Combustible and Toxic gases Oxygen enrichment & deficiency – – – – Exceptional capability – – – Shown in Single Strobe Configuration Percent remaining sensor life Sensor auto-recognition and configuration Uploads application parameters and gas & alarm data Time-stamped event and calibration data Meets the demands of a many industrial and heavy commercial applications Supports Plus Series sensor transportable calibration Ideal for manufacturing, laboratories, control rooms, and gas storage rooms SensAir CMB Cost effective, heavy duty combustible gas detector with enhanced poison resistance. High performance catalytic bead sensor – – Factory Mutual approved – – Enhanced poison resistance to Sulfides and Silicon for continued monitoring in contaminated environments Long life sensor for reduced ownership costs Division 1 & Division 2 approval ATEX Zone 1 & Zone 2 approval Explosion-proof 316 stainless steel sensor housing – – – High resistance to corrosion Horizontal or vertical orientation options Non-intrusive interface with display with magnetic switches SensAir CMB Ultimate solution for OEM and high-volume applications. Easy installation and maintenance – Designed for flexible installation in new facilities or retrofit – 3-wire, 4 – 20 mA output Bright RED three digit LED display – High-visibility indication of gas concentration – Blind transmitter available – Six LEDs corresponding to magnetic switches and alarms SensAlert Alarm Annunciators Added visual and audible annunciation for warning workers and supervisors. Local alarm annunciation – Warning of gas hazard alarms to nearby workers and supervisors – Communicates warning to follow alarm procedures or not to enter Single and dual strobe options Available power supply to power transmitters Annunciation models available general purpose (shown left) or hazardous area approved Sample Draw System Approved solution for monitoring gas in remote or difficult to access applications. FM listed for NFPA 820 compliance – – – Pumped or air aspirated versions – – – Approved for remote sampling in Class 1 Division 2 areas from Class 1 Division 1 areas Flexible solution to overcome challenging gas detection applications Decreases personnel time hazardous areas Flow sensor with fail-safe relay Internal power switch and flow adjustment External flow indication and LED’s 24 VDC power source for gas detectors – – Power up to four transmitters Allows for stand-alone system with the addition of annunciation SensAlert 4-Channel Controller Four channel controller with smart features for SensAlert family transmitters. Ultimate companion for SensAlert family gas detectors – Automatic sensor recognition and configuration for most Plus Sensors – Easy push-button interface for custom setup – 24 VDC power source for up to four gas detectors Application-flexible – NEMA 4X fiberglass wall-mount enclosure – Single, dual, or non- strobe options – Three alarm relays per channel – Common fault relay Model 9000 Dual & Quad Two or four channel control panel for display and management of inputs. Easy management of two or four channels of gas detection – Internal relays for annunciation or startup of hazard mitigation sequence – Graphic backlit LCD display – Accepts two or four 4-20 mA inputs Rich in features and capability – RS-485 Modbus RTU output – CSA approved for Class 1 Division 2 – Discrete alarm relays Model 7100 Eight or Sixteen Channel Advanced control panel for display and management of inputs. Accepts eight or sixteen gas detector inputs – Monitors 8 or 16, 4-20 mA inputs – Scaleable for future expansion – Wall-mount enclosure or rack-mount configuration Exceptional display & alarm logic – Common alarms with acknowledge function – Discrete alarms with voting, grouping, – full configuration and 24 hour trending – Optional discrete 4-20 mA outputs – Dual (Master and Slave) RS-485 Modbus RTU outputs Factory Commissioning & Service Ensure safety through expert start-up, repair, calibration, and maintenance. Start-up and Commissioning – Contracted on-site calibration or maintenance – On site start-up of equipment, functional testing, initial calibration, and training of local personnel Routine calibration and maintenance services by expert technicians Sensor Calibration and Exchange Program – – – – Scheduled delivery of factory calibrated sensors Customer’s second set of sensors stored at factory until next calibration interval Sensors tested in Sensidyne’s Factory Mutual (FM) approved lab Sensors ship with calibration certificate Accessories and Calibration Tools to solve difficult gas detection applications and maintain calibration. Remote Sensor Mounting – The unique ToD cell manually or automatically bump tests the sensor at user set intervals with a configurable result notification Rainshield – Prevents wind blown water from contacting the sensor and adversely affecting performance Duct Mount Fixture – – Provides general duct, vent hood, or air intake monitoring for gases Snap in membrane protects sensor from dust, particles, and reduces moisture transients Aspirated Sample Draw – Used in sampling systems to present sample to the gas sensor Moisture/Particulate Barrier Used with remote sensors for routine calibration or bump testing from the transmitter location ToD™ Gas Generator – Flow Through Cell (Flowblock) – Extension kits are provided to mount sensors high, low or in difficult locations up to 100ft (30m) Remote Calibration Adapters – Uses an air aspirator to draw a sample from a confined space, ceiling or other difficult to access location Pumped Sample Draw – Same as above but employs a motorized pump to draw a sample Sensidyne Fixed Gas Detection The most dependable solutions for gas detection.