3 Test, Measurement and Facilities Locating Dynatel™ Diagnostic Testing Equipment Subscriber Loop Products 900 Series 270 Subscriber Loop Tester 946DSP 279 Qualification Test Sets 949 and 950 ADSL 284 Advanced Modular System 965AMS 288 How to Search this Catalog This digital catalog provides you with two quick ways to find the products and information you’re looking for. Just point and click on the bookmarks to the left or the labeled sections of the table of contents. You can also use the “search” function built into Adobe Acrobat to jump directly to any text reference in this document. Acrobat “Search” function instructions: 1. Press CONTROL + F 2. When the dialog box appears, type in the word or words you are looking for and press ENTER. 3. Depending on your version of Acrobat, it will either take you directly to the first instance found, or display a list of pages where the text can be found. In the latter, click on the link to the pages provided. How to Search the 3M Website 3M Solutions Tool The solutions tool is designed to show you the breadth of the 3M product line and allow you to drill into specific categories to identify solutions. To use this free Internet support tool, visit: http://www.3M.com/Telecom. 269 3M™ Dynatel™ Subscriber Loop Test Products 900 Series Rugged and portable for harsh environments, Dynatel 900 series test sets offer the right mix of functions, from loop diagnostic routines to fault locating, transmission testing and combination test/terminal capabilities. Subscriber Loop Analyzer 965DSP The 965DSP analyzer is a microprocessor-controlled integrated test set that provides fullfeatured POTS, wideband and DSL-specific testing. The functions include fault location and repair verification on twisted-pair and drop cables (utilizing capacitance bridge, resistance bridge and Time Domain Reflectometer (TDR) functions). The 965DSP analyzer executes a wide range of individual tests, or performs automatic test routines to categorize and sectionalize problems. The hand-held set is housed in a lightweight, ergonomically designed case for portability and ease of handling. It is weather-resistant and weighs only 4.3 pounds (1.95 kg) with battery, test leads and soft case. 270 www.3MTelecommunications.com 800-426-8688 3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES The 965DSP/SA subscriber loop analyzer delivers all the multi-function capabilities of the 965DSP tester and provides a spectrum analyzer and E, F and G noise-weighted filters. Wideband noise measurements are made with the E (ISDN/ISDL), F (HDSL) and G (ADSL) filters. The spectrum analyzer test function enables the operator to view the DSL frequency spectrum and identify spectral interferers such as crosstalk noise generated by other services. Subscriber Loop Analyzers 965DSP/ADSL and 965DSP/SA/ADSL The 965DSP/ADSL and 965DSP/SA/ADSL subscriber loop analyzers feature an Alcatel™ MTK-20150 modem chipset in the proven 965DSP platform. The 965DSP/ADSL tester provides active ADSL testing to address the growing number of residential and business ADSL customers. It delivers all the multi-function capabilities of the 965DSP tester plus the testing functions of the ADSL modem. The 965DSP/SA/ADSL test set adds comprehensive DSL parametric measurements to this integrated solution. Extended loss measurement ranges, spectrum analyzer and E, F and G filtered wideband noise measurements complete this comprehensive family of rugged loop testers. The units are weather resistant and weigh only three pounds (4.5 lbs. with test leads and soft case). Preserving the rugged dependability of all Dynatel products, the ADSL option incorporates a durable “spacer” element to the current 965DSP molded plastic case to permit easy and robust expansion of the ADSL circuit board. Far End Device II Designed to provide remote controlled far end testing assistance during subscriber loop testing, the far end device II is a companion to the Dynatel 965DSP family of subscriber loop analyzers where the “one person out” concept has been implemented. The FED device can enhance technician productivity by connecting to the far end of a cable pair to enable diagnostic testing from the near end using the DTMF signaling capability of the 965DSP, 965DSP/SA, 965DSP/ADSL and Test, Measurement and Facilities Locating — Diagnostic Testing Equipment Subscriber Loop Analyzer 965DSP/SA 965DSP/SA/ADSL test sets. PRODUCT REFERRAL GENERATOR Accessories and Replacement Parts . . . . . . . . . . pg. 282 271 3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES Subscriber Loop Tester 945DSP The Dynatel 945DSP subscriber loop tester is a microprocessorcontrolled test set that provides full-featured POTS testing. The tester performs a wide range of voice band tests to analyze problems on twisted-pair cables. Weather-resistant and weighing only 1 pound, the hand-held 945DSP test set is housed in a lightweight case for portability and ease of handling. KIT CONTENTS SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES PRODUCT DESCRIPTION 965DSP 965DSP/SA 965DSP/ADSL 965DSP/SA/ADSL 945DSP • • • • • Standard Accessories Analyzer Nickel metal hydride battery pack • • • • AC adapter • • • • Specified test cables • • • • Alkaline battery holder • • • • Conductor strap • • • • Wire gauge • • • • Self-test circuit board • • • • Instruction manual • • • • ADSL modem Optional Optional • • Spectrum analyzer Optional • Optional • 054007-31253 054007-31253 054007-31253 054007-31253 Specified batteries 1030 conductor gauge • • 4 alkaline AA 054007-31253 Alkaline battery holder/adapter 051138-57685 051138-57685 051138-57685 051138-57685 — 110/220 VAC adapter 051138-58628 051138-58628 051138-58628 051138-58628 — Softcase (model 1151) 051138-87178 051138-87178 051138-87178 051138-87178 051141-04458 Nickel metal hydride battery pack 051138-57686 051138-57686 051138-57686 051138-57686 — 1144 black/red test lead, alligator, bed-of-nails 051138-57648 051138-57648 051138-57648 051138-57648 051138-57648 1142 blue/yellow test lead, alligator, bed-of-nails 051138-57649 051138-57649 051138-57649 051138-57649 — 1143 green test lead, alligator, bed-of-nails 051138-57650 051138-57650 051138-57650 051138-57650 051138-57650 Shorting strap, alligator 051138-58529 051138-58529 051138-58529 051138-58529 — Optional Accessories 272 Black/red test lead, 4 mm banana 051138-57608 051138-57608 051138-57608 051138-57608 — Blue/yellow test lead, 4mm banana 051138-57610 051138-57610 051138-57610 051138-57610 — Green test lead, 4mm banana 051138-57612 051138-57612 051138-57612 051138-57612 — Shorting strap, 4 mm banana 051138-58532 051138-58532 051138-58532 051138-58532 — Video training tape 054007-71941 — — — — Cigarette lighter adapter 051138-57744 051138-57744 051138-57744 051138-57744 — IR adapter cable 051138-58764 051138-58764 051138-58764 051138-58764 — Far End Device FED II 1342 with alligator clips 051138-87639 051138-87639 051138-87639 051138-87639 — Far End Device FED II 1343 (bed-of-nails test clips) 051138-87640 051138-87640 051138-87640 051138-87640 — Far End Device FED II 1344 (single needle) 051138-89794 051138-89794 051138-89794 051138-89794 — FEATURES 3M™ DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES FEATURES 965DSP 965DSP-B 965DSP/SA 965DSP/ADSL 965DSP/SA/ADSL • • • • • 945DSP Open fault locate • • • • • • Load coil count • • • • • Optional Longitudinal balance • • • • • • Caller Identification (CID) • • Split fault locate • • • • • • • Voltage measurement • • • • • • Tone source • • • • • • Current measurement • • • • • • Ohms measurement • • • • • • Soak test • • • • • • Ohms-to-distance conversion • • • • • Loss measurement • • • • • • Noise measurement • • • • • • Ringers count • • • • • Optional Self-test and self-calibration • • • • • Wideband noise/loss for ISDN and xDSL • Line prequalification tests for basic rate ISDN service • TDR • IR port (communication port) • Stored results internal memory • Communications craft set • • • • • • • • • • • • • • • • • • • • • Feet, meters, Fahrenheit, Celsius Feet, meters, Fahrenheit, Celsius Feet, meters, Fahrenheit, Celsius Feet, meters, Fahrenheit, Celsius Feet, meters, Fahrenheit, Celsius Feet, meters, Fahrenheit, Celsius • • • • • • Auto diagnostic DC testing (loop) • • • • • Auto diagnostic AC testing (transmission) • • • • • High insulation resistance test • • • • • Resistance difference and loop resistance • • • • • Optional • • Optional • • • • • • Measurement units Graphic display (backlit) Spectrum analyzer (includes E, F, G noise filters) Fast kick test Onboard operating instructions ADSL active modem testing • • • • • Optional Optional Optional • • Test, Measurement and Facilities Locating — Diagnostic Testing Equipment Resistance fault locate 273 ORDERING INFORMATION ™ 3M DYNATEL™ SUBSCRIBER LOOP TEST PRODUCTS 900 SERIES 965DSP-A 965DSP-B 965DSP-A/SA 965DSP-A/ADSL 965DSP-A/SA/ADSL 1/cs. 1/cs. 1/cs. 1/cs. 1/cs. 1/cs. 1 each 1 each 1 each 1 each 1 each 1 each Nickel metal hydride batteries, bed-of-nails clips 051138-57603 051138-58643 051138-88358 051115-14490 051115-14488 — Nickel metal hydride batteries, bed-of-nails clips and 3M Dynatel Far End Device 1343 Packaging Minimum order 274 945DSP 051138-89791 051138-89790 051115-14740 — 051115-18506 — Nickel metal hydride batteries, bed-of-nails clips and AC/DC chargers — — 051115-16144 — — — Nickel metal hydride batteries, bed-of-nails clips, AC/DC chargers and 1343 far end device — — 051115-16143 — — — Nickel metal hydride batteries, 4mm banana plugs and multi-language 051138-70088 051138-87781 051138-87782 051115-14492 051115-14493 — Nickel metal hydride batteries and single-needle clips — — — 051115-14491 051115-14489 — Bed-of-nails clips/c-message weighting — — — — — 051115-104452 Bed-of-nails clips/c-message weighting, w/ soak, ringers and load count — — — — — 051115-17989 www.3MTelecommunications.com 800-426-8688 ELECTRICAL SPECIFICATIONS 3M™ DYNATEL™ SUBSCRIBER LOOP ANALYZER 965DSP (A, B AND SA) RANGE RESOLUTION ACCURACY Voltage (DC) 0 to 99.9 V 100 to 300 V 0.1 V 1V 1% ± 0.5 V 3% Voltage (AC) 0 to 99.9 V 100 to 250 V 0.1 V 1V 1% ± 0.5 V 3% Current 0 to 59.9 mA 60 to 110 mA 0.1 mA 0.1 mA 1% ± 0.3 mA 2% Resistance and soak test with CO voltage 0 to 9999 Ω 0 to 9999 Ω 10 k to 99.9 kΩ 100 k to 999 kΩ 1 M to 9.9 MΩ 10 M to 99 MΩ 100 M to 990 MΩ 1Ω 1Ω 0.1 kΩ 1 kΩ 0.1 MΩ 1 MΩ 10 MΩ 1% ± 5 Ω 1% ± 50 Ω 1% 3% 3% 5% 10% Opens (no noise) 0 to 3,000 ft. (0 to 1000 m) 3,000 to 10,000 ft. (1 km to 3 km) 10,000 to 50,000 ft. (3 km to 15 km) 50,000 to 100,000 ft. (15 km to 30 km) 1 ft. (1 m) 1 ft. (1 m) 10 ft. (10 m) 100 ft. (100 m) 1% ± 3 ft. (1 m) 3% 5% 10% 0 to 20 MΩ 0 to 99.99 Ω RTS 100 to 999.9 Ω RTS 1 kΩ to 7 kΩ RTS — 0.01 Ω 0.1 Ω 1.0 Ω — 0.1% of RTS ± 0.01 Ω 0.2% of RTS ± 0.01 Ω 1.0% of RTS ± 0.01 Ω Loss (and frequency) with 600 Ω Zin with 135 Ω Zin -40 to +10 dBm, 200 to 20kHz -50 to +2 dBm, 20 k to 1200 kHz 0.1 dB, 1Hz, 1kHz 0.1 dB, kHz 0.5 dB, 1% 2 dB, 1% Noise metallic 0 to 50 dBrnc (-90 to -40 dBm0p) 1 dB 2 dB Noise to ground 40 to 100 dBrnc (-50 to 10 dBm0p) 1 dB 2 dB Longitudinal balance 0 to 70 dB 70 to 85 dB 1 dB 1 dB 2 dB — Wideband - 135 Ω Zout 200 to 1000 Hz, fixed level 200 to 9999 Hz, -20 to +1 dBm 10 k to 19.99 kHz, -20 to +1 dBm 20 k to 1200 kHz, 0 dBm — 1 Hz, 0.1 dB 1 Hz, 0.1 dB 1 kHz — 1% Hz, 0.2 dB 2% Hz, 1 dB 1 dB Dial mode DTMF, Pulse — — TDR Under typical conditions a 500 ft bridge tap can be seen at 18,000 ft on a 20,000 ft 24 AWG cable. (150 m bridge tap at 5500 m on a 6000 m 0.5 mm cable). 100, 200, 500, 1,000, 2,000 5,000, 10,000, 20,000, 30,000 ft, (30, 60, 150, 300, 600, 1,500 3,000, 6,000, 10,000 m) 1 ft. (1 m) 0.6% range Pulse width Velocity input Modes 5 nS, 34 nS, 235 nS, 1600 nS 0.50 to 0.99 (150 to 299 m/µs) Single trace, dual trace, differential, memory, crosstalk, peak — 0.01 (1 m/µs) — Fixed values — — Auto-tests Same specifications as full tests See above See above Active/inactive Near-end and far-end block errors — 1 block error — 1 block error -75 to +5 dBm, 20 kHz to 1200 kHz 1 dB 1 dB +10/+20/+30 to +90 dBrn +40/+50/+60 to + 120 dBrn 1 dB 1 dB 2 dB 2 dB 10 kHz to 1.8 MHz from 120kHz to 2 MHz -90 to +10 dBm 1% of span 135Ω — — — — — — — — RFL Fault range Resistance to fault (no noise) Tone output ID Precision - 600 Ω Zout SA Functions (ISDN/IDSL, HDSL, ADSL) ISDN (2B1Q) Link test Error test (US and Canada only) DSL Loss (and frequency) with 100 Ω or 135 Ω Zin Noise (with E, F, and G filters) Metallic with100 Ω/135 Ω Zin Longitudinal with 10 kΩ Zin Test, Measurement and Facilities Locating — Diagnostic Testing Equipment MAIN FUNCTIONS Wideband Spectrum Analyzer Range 5 spans Dynamic range Frequency resolution Input impedance 275 SPECIFICATIONS ™ 3M DYNATEL™ SUBSCRIBER LOOP ANALYZER 965DSP (A, B AND SA) PHYSICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Size H x W x D in. (cm) 10.3 x 4.7 x 3.2 (26.2 x 12 x 8.1) Operating temperature 0° to 140°F (-18 to 60°C) Net weight lbs. (kg) 4.3 (1.95) with battery and soft case Storage temperature -40° to 165°F (-40 to 75°C) Shipping weight lbs. (kg) 7.8 (3.54) Humidity 0 to 95%, non-condensing Material GE Xenoy ACCESSORIES DESCRIPTION Test leads U.S. – 5 ft. (1.5 m) test leads with 2 mm gold-plated banana plugs on one end and chrome-plated alligator clips on other end (black/red, blue/yellow, green) European – 5 ft. (1.5 m) test leads with 2 mm gold-plated banana plugs on one end and 4 mm gold-plated banana plugs on other end (black/red, blue/yellow, green) RFL strap U.S. – 1.5 ft. (0.5 m) with alligator clips on ends European – 1.5 ft. (0.5 m) with banana plugs on ends AC/DC battery charger 100-250 VAC (50/60 Hz) input; 12 VDC (1 A) output. For charging only. Do not operate when using charger. Soft case Heavy-duty fabric case for unit and test leads Battery holder Plastic holder for 6 AA (LR6) batteries Battery pack Custom 1.5 amp-hour nickel metal hydride TOOLBOX FUNCTIONS RANGE RESOLUTION ACCURACY Load coil count 0 to 5 1 ±1 Ohms/distance calculator 0 to 9999 ohms 0 to 99999 ft (0 to 30 km) 0.01 Ω 1 ft (0.1 m) — — Caller ID (U.S. and Canada only) Carrier level Date, time, number, name -4 to -32 dBm — 1 dBm — 2 dBm Self-calibrate Pass/fail — — Loop resistance 0 to 99.9 Ω 100 to 999.9 Ω 1000 to 7000 Ω 0.01 Ω 0.1 Ω 1Ω 0.1% ± 0.01 Ω 0.2% ± 0.01 Ω 1.0% ± 0.01 Ω Resistance difference 0 to 99.99 Ω 0.01 Ω 1% of loop resistance ± 0.01 Ω Ground resistance 5 to 500 Ω 1Ω 1% ± 1 Ω 0 to 7K Ω (Fault Res1) > twice (Fault Res2) 0 to 99 Ω 100 to 999 Ω 1K to 3.5K Ω __ __ 0.01 Ω 0.1 Ω 1Ω __ __ 5% 5% 5% K-Test Loop resistance Fault ratio Resistance to fault (no noise) Stored results (Autotest and TDR) 100 results of each, minimum — — Ringers 0.0 to 4.0 0.1 ringer equivalent General specifications GENERAL SPECIFICATIONS Ruggedness Survives 5 ft. (1.5 m) drop in soft case Water-resistance Splashproof; may be used in light to moderate rain Standards Meets FCC part 15, class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity) EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe. Built to ISO9001 certification for manufacturing facilities. Built to Bellcore (Telcordia Technologies) TSY000078 manufacturing methods. Meets UL50 Rain Test. Language English and multi-languages Units Feet or meters, Fahrenheit or Celsius, dBrnC or dBm0p, m/uS or Vp Battery life Rechargeable battery pack, 12 hours typical usage (no backlight), 4 hours typical (with backlight); typical usage defined as 30 minutes on, 30 minutes off Charging time Minimum 2.5 hours from low to full Keypad 24-key membrane keypad with tactile feedback Display in. (cm) 2.5 x 2.5 (74 x 74), 192 by 192 pixel resolution, backlight Note: Routine calibration is not recommended or required. 276 www.3MTelecommunications.com 800-426-8688 SPECIFICATIONS 3M™ DYNATEL™ SUBSCRIBER LOOP ANALYZER 965DSP SERIES WITH ADSL MODEM PHYSICAL SPECIFICATIONS 10.3 x 4.6 x 3.75 (26.2 x 11.7 x 9.5) Net weight lbs. (kg) with soft case and test leads 4.5 (2) Shipping weight lbs. (kg) 8 (3.6) ENVIRONMENTAL SPECIFICATIONS Operating temperature 0˚ to 140˚ F (-18˚ to 60˚ C) Storage temperature -40˚ to 165˚ F (-40˚ to 75˚ C) Humidity 0 to 95%, non-condensing Vibration Random 3-axis vibration for 20 minutes Water resistance Meets UL50 Rain Test Shock 10 drops on corners and sides from 30 in. (without soft case) and 10 drops on corners and sides from 60 in. (with soft case) Safety IEC950 OPERATIONAL SPECIFICATIONS Product will incorporate all the features of the 965DSP and/or 965DSP/SA subscriber loop analyzers at the accuracy currently specified for these products (see 965DSP family product documentation). ADSL datalink capability is limited to link synchronization. No ‘PING’ or data application capability is provided. Modem will initiate a connection with the far-end under operator command. Status messages indicating link progress will be returned. ANSI/ITU standards supported ITU G.992.2 (G.Lite), ITU G.992.1 (G.DMT), ANSI T1.413 Issue 2 ADSL modes ANSI, G.DMT, G.Lite, MultiMode Reach Designed to synchronize at distances from 0 ft. to 18,000 ft. Statistics Actual and maximum upstream and downstream connect rates Upstream and downstream percent used ADSL line capacity Upstream and downstream noise margin Upstream and downstream signal attenuation Upstream and downstream power levels Modem manufacturer identification (ANSI mode only) Upstream and downstream FEC, CRC, and HEC counts Alarm codes including LOS, LOF, LCD and LOM Graphical display of bits-per-bin count for the DMT signal Operating modes Captured – Modem auto-disconnects from the far-end after statistics gathered Continuous – Modem gathers statistics for up to ten minutes Test, Measurement and Facilities Locating — Diagnostic Testing Equipment Size H x W x D in. (cm) 277 SPECIFICATIONS ™ 3M DYNATEL™ SUBSCRIBER LOOP TESTER 945DSP MEASUREMENT FUNCTION RANGE RESOLUTION Size H X W X D in. (cm) Cord length ft. (m) Net weight lbs. (kg) 1 (.5) Shipping weight lbs. (kg) 1.5 (0.7) Operating temperature -30° to 140° F (-34° to 60° C) Storage temperature -40° to 140° F (-40° to 60° C) Relative humidity 0 to 95% Display in. (cm) 2.25 x 1.25 (5.7 x 3.2) AC voltage 0 to 75 V 75 to 250 V 1.0 V 1.0 V ±1 V ±3 V ±100 to ±350 V 0 to ±100 V 1.0 V 1.0 V ±3 V DC current 0 to ±110 mA 1.0 mA ±2 mA Resistance 0 to 999Ω 1kΩ to 9.9KΩ 10kΩ to 999KΩ 1MΩ to 9.9MΩ 10MΩ to 30MΩ 1Ω 100Ω 1 kΩ 100kΩ 1 MΩ ±5 Ω or 3% ±3% ±3% ±3% ±10% DC voltage Noise metallic (with C-message weighting*) 0 to 60 dBrnc 1 dB ±2 dB Noise to ground (with C-message weighting*) 40 to 100 dBrnc 1 dB ±2 dB 0-9999 ft. 10k to 20k ft. 0 to 6000 m 1 ft. 1k ft. 1m ±20 ft., ±5% ±5% ±6 m, ±5% Opens Ground resistance 0 – 50 Ohm 1Ω ±3 Ω Loop loss -50 to +10 dBm 1 dB ±1 dB Frequency during loss, single frequency only 200 to 5,000 Hz 1 Hz ±3 Hz Longitudinal balance 0 to 65 dB 1 dB ±2 dB Tone output ID Precision - 600 ΩZout 577.5 Hz 404,1004,2804Hz Power source 0 ±.5 dBm 4 - Disposable Alkaline (AA or LR6) but will accept user provided Ni-Cad or NiMH batteries with user provided external charger Typical battery life Over voltage protection Vibration Alkalines: 40 hours of typical use, 15 hours continuous 450 VDC, 250 VAC Between any leads to protect the internal circuit. Random 3-axis vibration at 12.5Grms for 20 minutes Rain proof/splash proof Shock Meets UL50, rain test 10 drops on corners and sides from 30 in. without the soft case and 10 drops from 60 in. in soft case EMI/EMC Meets FCC part 15, Class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity), EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe. Keypad ON/OFF switch, numeric key pads, which also function as the function keys. Function keys V (voltage), mA (loop current/ground resistance), Ω (resistance/soak test), OPENS, TONE, DB, AUTO Cal. Two non-testing function keys are ‘*’ and ‘#’. *Psophometric filter is available as a special order. 278 ACCURACY ± 7.5 x 4 x 1.5 (19 x 10.2 x 3.8) 5 (1.5) www.3MTelecommunications.com 800-426-8688 ±1 V 3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 946DSP 945DSP tester with the following additions specific to acceptance testing of new telephone installations: The ability to count up to 5 load coils, auto-test: V (T,R,Gnd), mA, Ground Resistance, Ohms (T,R,Gnd), Opens (T,R,Gnd), Load Coil Count, Noise, PI, LB and Loss (up to 10 frequencies), storage of up to 10 full sets of test results including the ability to review any of the 10 results in the field on the 946DSP, and upload stored results to a PC using an adapter cable. FUNCTION DESCRIPTION Voltage (V) Detects and measures the presence of central office or foreign DC and AC voltages on R-T, R-G and T-G. Current (mA) Measures DC loop current. Ground resistance When measuring mA, press the set up key to measure and display the ground path resistance (when supported by the switch). Resistance test Measures conductor and insulation resistance up to 30 megohms. Accurate readings in the presence of foreign voltage. Full autoranging. Insulation soak test Monitors the leakage resistance from the test leads to ground and indicates changes in the insulation resistance over time in the presence of high voltage. Increasing resistance is an indication of a wet fault and decreasing resistance is an indication of oxidation, which is breaking down and becoming more conductive. Opens Measures the open length of tip, ring or cable pair at distances up to 100,000 ft, (30 km). Tone Provides 577 Hz ID tone for conductor identification, and 404, 1004 and 2804 Hz precision tones for determining circuit loss. Loss Measures voiceband loss up to 5KHz, displaying frequency and level. Noise Measures circuit noise and power influence, and displays calculated balance. C-Message Weighting is used in the U.S. and Canada, and a Psophometric Filter where ITU (CCITT) Standards are used. Longitudinal balance This test provides active measurement of line balance. Dial key Allows storage of 10-14 digit numbers for testing of active lines. Load coils Counts up to 5 load coils on an unterminated pair. Result summary screen This screen shows the results from last V, mA, Ground Resistance, Ohms, Opens, Load Coil Count, Noise, PI, LB and Loss test in a tabular form for easy analysis. If desired, these results can then be saved to one of 10 result storage locations. Result storage Storage will be provided for 10 sets of results. Each set will include a 10 digit numeric identifier and the following measurements: V (T-R), V (T-G), V (R-G), mA, Ground Resistance, Ohms (T-R), Ohms (T-G), Ohms (R-G), Open Length (T-R), Open Length (T-G), Open Length (R-G), Load Coil Count, Noise, Power Influence, Longitudinal Balance and Loss at up to 10 different frequencies. Result review Means will be provided to review any result set on the screen of the 946DSP. Result upload Results can be uploaded to a PC through the test leads using an adapter and pc software provided with the unit. Test, Measurement and Facilities Locating — Diagnostic Testing Equipment The 946DSP subscriber loop tester has all the features of the current 279 ELECTRICAL SPECIFICATIONS 3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 946DSP FUNCTION Voltage (AC) Voltage (DC) Loop current (DC) Loop resistance Leakage resistance and insulation soak Loop loss RANGE RESOLUTION ACCURACY* TEST LEADS R-T, R-G, T-G 0 to 75 VAC 1V ±1 V 75 to 250 VAC 1V ±3 V R-T, R-G, T-G 0 to ± 100 V 1V ±1V R-T, R-G, T-G ±100 to ±350V 1V ±3V R-T, R-G, T-G 0 to ±110 mA 1 mA ±2m A R-T (Zin = 430 Ω) 0 to 999 Ω 1Ω ± 5 Ω or 3% R-T, R-G, T-G 1kΩ to 9.9kΩ 10kΩ to 99.9kΩ 100kΩ to 999kΩ 1MΩ to 9.9MΩ 10MΩ to 30MΩ 10 Ω 100 Ω 1kΩ 100kΩ 1MΩ ± 3% ± 3% ± 3% ± 3% ± 10% R-T, R-G, T-G R-T, R-G, T-G R-T, R-G, T-G R-T, R-G, T-G R-T, R-G, T-G -50 to +10 dBm 1 dB ±1 dB R-T (Zin=600) 200 to 5000 Hz Noise metallic with C-message weighting** 0 to 60 dBrnc 1 dB ±2 dB R-T (Zin=600) Noise to ground with C-message weighting** 40 to 100 dBrnc 1 dB ±2 dB R and T-G(Zin=100K) Ring, tip, mutual Opens Frequency during loss, single frequency only Longitudinal balance Ground resistance Load coils 0 to 9,999 ft. 1 ft. ± 20 ft. ±5% 10,000 to 99,999 ft (0 to 9,999 m) (10,000 to 30,000m) 100ft (1 m) (100m) +/- 5% ( ± 6m, ±5%) (+/- 5%) 200 to 5,000 Hz 1 Hz ±3 Hz R-T 0 to 65 dB 1 dB ±2 dB TR-G 0 to 50 Ω 1 Ω ±3Ω Count 0,1,2,3,4 or >4 coils +/- 1 coil Note: First load must be >3000’ from the unit and 3000’ of cable must extend beyond the last load coil for an accurate count *Percent of reading **C-message specification has additional frequency dependent tolerance. Refer to “Subscriber Loop Transmission Test Set Specification”, Bell System PUB 55020, January 1982. 280 OUTPUT FREQUENCY AMPLITUDE ATTACHMENT REMARKS ID tone Precision tone 577.5 Hz 404,1004, 0 2804 Hz 8 Vpp ±0.5 dBm R-T R-T Squarewave, interrupted 600Ω source, continuous sinewave. <10%THD www.3MTelecommunications.com 800-426-8688 PHYSICAL SPECIFICATIONS 3M™ DYNATEL™ SUBSCRIBER LOOP TESTER 946DSP WEIGHT (INCLUDING BATTERIES) SHIPPING WEIGHT DISPLAY SIZE (7.5"H x 4"W x 1.5"D ) 19 cm x 10.2 cm x 3.8 cm 1 lb. with battery and soft case (0.5 kg) 1.5 lbs (0.7 kg) 2.25" x 1.25" (5.7 cm x 3.2 cm) ENVIRONMENTAL SPECIFICATIONS SUBSCRIBER LOOP TESTER 946DSP Operating temperature 0° to 140°F (-17° to 60°C) Storage temperature -40° to 140°F (-40° to 60°C) Humidity 0 to 95% Vibration Random 3-axis vibration at 12.5 Grms for 20 minutes Rain proof/splash proof Meets UL50, Rain test EMI/EMC Meets FCC part 15, Class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity), EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe. GENERAL SPECIFICATIONS SUBSCRIBER LOOP TESTER 946DSP Batteries 4 - disposable alkaline (AA or LR6) but will accept user provided Ni-Cad or NiMH batteries with user provided external charger Battery life Alkaline: up to 25 hours continuous, dependent on temperature and use of backlight. Dialing DTMF and pulse dialing - 10 number storage (50% on/off measures voltage) Display Graphical LCD with universal icons Test leads Removable red, black and green leads; 5 ft. (1.5 m) Over voltage protection 450 VDC, 250 VAC. between any leads to protect the internal circuit Keypad Field-rugged, waterproof membrane keypad Function keys V (voltage), mA (loop current/ground resistance), ohms (resistance/soak test), OPENS, TONE, DB, AUTO Cal. Two non-testing function keys are ‘ * ’ and ‘#’ Note: Routine calibration is not recommended or required ** Percent of reading ** Psophometric filter is available as a special order 12 hours typical use Test, Measurement and Facilities Locating — Diagnostic Testing Equipment 946DSP SIZE (H X W X D) IN. (CM) 281 3M™ DYNATEL 900 SERIES SUBSCRIBER LOOP TEST PRODUCT ACCESSORIES 282 PRODUCT NUMBER/ PACKAGING INFO DESCRIPTION 1146 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-57744 Cigarette Lighter Adapter For 965DSP tester. 1149 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-57685 Alkaline Battery Holder For 900 series tester. 1145 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-58628 Adapter 110/220 VAC For 965DSP tester. 1148 PKG. (LBS.): 1 EACH (0.44) MIN. ORDER: 1 EACH UPC: 051138-57686 Nickel Metal Hydride Battery Pack For 965DSP tester. 1151 PKG. (LBS.): 1 EACH (0.20) MIN. ORDER: 1 EACH UPC: 051138-87178 Soft Carrying Case For 965DSP and 965DSP/SA testers. 1181 PKG. (LBS.): 1 EACH (3.00) MIN. ORDER: 1 EACH UPC: 051115-15090 Soft Carrying Case For 965DSP/ADSL tester. 1147 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-58529 Ground Strap, Shorting, Alligator For 965DSP tester. 900-IR PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-58764 IR Adapter Cable For 900 series tester. www.3MTelecommunications.com 800-426-8688 3M™ DYNATEL 900 SERIES SUBSCRIBER LOOP TEST PRODUCT ACCESSORIES DESCRIPTION 1142 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-57649 Lead Test, Blue/Yellow Alligator Clip and Bed-of-Nails For 965DSP tester. 1143 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-57650 Green Lead Test Alligator Clip and Bed-of-Nails For 945DSP and 965DSP testers. 1144 PKG. (LBS.): 1 EACH (0.10) MIN. ORDER: 1 EACH UPC: 051138-57648 Black/Red Lead Test Alligator Clip and Bed-of-Nails For 945DSP and 965DSP testers. 1342 PKG. (LBS.): 1 EACH (2.00) MIN. ORDER: 1 EACH UPC: 051138-87639 Far End Device II Use with 965DSP tester with alligator clips. 1343 PKG. (LBS.): 1 EACH (2.00) MIN. ORDER: 1 EACH UPC: 051138-87640 Far End Device II Use with 965DSP tester with bed-of-nails and alligator clips. 1344 PKG.: 1 EACH MIN. ORDER: 1 EACH UPC: 051138-89794 Far End Device II With alligator clip and long/single needle. 1110 PKG.: 1 EACH MIN. ORDER: 1 EACH UPC: 051115-13550 Test Lead with RJ45/Alligator Clip, 7 Leads For 1342 far end device II. Test, Measurement and Facilities Locating — Diagnostic Testing Equipment PRODUCT NUMBER/ PACKAGING INFO 283 3M™ DYNATEL™ QUALIFICATION TEST SETS 949 AND 950ADSL The 949 and 950ADSL qualification test sets can provide a low-cost solution for POTS testing and verification of ADSL modem connectivity at customer locations. Rugged Reliable Design The Dynatel test sets are housed in a light-weight, hand-held case designed for ease-of-handling and portability. Each unit weighs less than 2.5 pounds with the rechargeable battery pack included. The Dynatel brand and its distinctive Dynatel yellow color are your assurances of rugged reliability. GENERAL SPECIFICATIONS QUALIFICATION TEST SET 950ADSL POTS test storage 10 Sets of results, each identified with a 10 digit numeric identifier. Stored results can be viewed in the test set. POTS auto-test Auto-test will run the following tests: V (T, R, G), mA, ground resistance, ohms (T, R, G), opens (T, R, G), load coil count, noise, PI, LB and loss (up to 10 voiceband frequencies). ADDITIONAL POTS MEASUREMENT SPECIFICATIONS QUALIFICATION TEST SET 950ADSL FUNCTION RANGE Loop current (DC) RESOLUTION ACCURACY* TEST LEADS R-T (Impedance = 430 ø) 0 to ±110 mA 1 mA ±2mA 0 ohm to 999 ohms 1 ohm ± 5 ohm ± 3% R-T, R-G, T-G -50 to +10 dBm 200 to 5000 Hz 1 dB ±1 dB R-T (Impedance = 600 ø) Frequency during loss, single frequency only 200 to 5,000 Hz 1 Hz ±3 Hz R-T Noise metallic with C-message weighting** 0 to 60 dBrnc 1 dB ±2 dB R-T (Impedance = 600 ø) Noise to ground with C-message weighting** 40 to 100 dBrnc 1 dB ±2 dB R and T-G (Impedance = 100KW) 0 to 9,999 ft. 10,000 to 99,999 ft (0 to 9,999 m) (10,000 to 30,000m) 1 ft. 100ft (1 m) (100m) ± 20 ft. ±5% +/- 5% (± 6m, ±5%) (+/- 5%) Ring, tip, mutual Longitudinal balance 0 – 65 dB 1 dB ±2 dB TR-G. Ground resistance 0 to 50 ø 1ø Loop resistance Loop loss Opens Load coils Note: First load must be >3000’ from the unit and 3000’ of cable must extend beyond the last load coil for an accurate count Count 0,1,2,3,4 or >4 coils ±3ø +/- 1 coil *Percent of reading **C-message specification has additional frequency dependent tolerance. Refer to “Subscriber Loop Transmission Test Set Specification”, Bell System PUB 55020, January 1982. 284 www.3MTelecommunications.com 800-426-8688 3M™ DYNATEL™ QUALIFICATION TEST SETS 949 AND 950ADSL Metallic tests conducted by the 949 and 950ADSL qualification test sets include CO and foreign voltage, insulation resistance, loop resistance, and longitudinal balance. As a tone source, the testers are capable of generating 200Hz and 2MHz sine wave tones. Additional qualification tests include ADSL modem linkup and essential performance measurements including connect rates, error statistics, and bingraph. Test sets also have the capability to ping to an ISP. ADSL test results can be saved and viewed in the unit or uploaded to a computer as needed. The 950 test set can perform a POTS autotest which can be saved and uploaded to a computer. PRODUCT FEATURES QUALIFICATION TEST SET TESTS PERFORMED 949ADSL TEST SET 950ADSL TEST SET Volts – AC and DC • • Loop current • Resistance test • Soak test • • Ground resistance • Opens • Loss and noise Longitudinal balance • • Dial key Load coils • • • POTS autotest • Precision tones to 2MHz • • ADSL connectivity • • PING testing • • FEATURES 949ADSL TEST SET 950ADSL TEST SET Backlit LCD • • RJ45 attachment for test leads • • Rechargeable NiMH battery • • Serial upload to PC • • Storage for 200 ADSL results • Storage for 10 POTS results • • Test, Measurement and Facilities Locating — Diagnostic Testing Equipment POTS and ADSL Tests 285 ADSL MEASUREMENT SPECIFICATIONS 3M™ DYNATEL™ QUALIFICATION TEST SETS 949 AND 950ADSL ADSL standards ANSI T1.413 ITU-T G.992.2 (G.LITE) ITU-T G.992.1 (G.DMT) - Annex A IP encapsulation LLC SNAP or VC MUX IP transport protocols DHCPoE – IP on Ethernet over ATM DHCPoA - IP over ATM StaticIPoE – IP on Ethernet over ATM StaticIPoA - IP over ATM PPPoE - PPP over Ethernet over ATM PPPoA - PPP over ATM PPP authentication CHAP or PAP Line impedance 100 ohms, nominally FUNCTION MEASUREMENT ACCURACY ADSL status Fast rate up/down Interleaved rate up/down Max rate up/down Margin up/down Attenuation up/down Capacity up/down +/- 1 kbps +/- 1 kbps +/- 1 kbps +/- 1 dB +/- 1 dB +/- 1 % ADSL information FEC errors up/down CRC errors up/down HEC errors up/down Bin graph +/- 1 +/- 1 +/- 1 ADSL alarms Loss of Signal (LOS) Loss of Frame (LOF) Loss of Power (LOP) Loss of Margin (LOM) Ping Connection time +/- 10mS GENERAL SPECIFICATIONS QUALIFICATION TEST SET 949ADSL 286 Size 60 mm high x 100 mm wide x 200 mm long Weight Less than 2.5 lb. with battery Battery NiMH 2.1 Ahr – shrink wrap pack, user replaceable through access door on back of unit Battery life 8 hours standby (Backlite Off) + 20 full ADSL qualification tests AC/DC adapter connects to the unit through the RJ45 test lead jack The unit cannot make measurements while powered by the AC/DC adapter Auto shutoff after 5 minutes with no activity, except during charging Display 64 x 128 pixel, 57 mm x 31 mm viewing area with LED backlight Test leads Red, black and green leads. 1.5 meter long. Connected to unit via RJ45 jack Breakdown voltage 360 VDC, 250 VAC. (the unit will be damaged if exposed to voltages exceeding these limits) Operating temperature -10°C to 60°C except for ADSL and battery charger functions 0°C to 60°C ADSL functions (temperatures > 50°C performance could degrade) 0°C to 50°C battery charger operation Humidity 0 to 80% non-condensing Rain proof/splash proof Conforms to IP42 Shock Will survive 3 foot drop to concrete Regulatory CE / FCC ADSL test storage 200 sets of results identified with an alphanumeric label Stored results can be viewed in the test set. Languages English RS232 port An RJ45 to DB9 adapter cable is provided to permit connecting the 949 and 950ADSL to a PC The serial connection supports the following: • Upload of test results to the PC • Field software updates www.3MTelecommunications.com 800-426-8688 POTS MEASUREMENT SPECIFICATIONS 3M™ DYNATEL™ QUALIFICATION TEST SETS 949 AND 950ADSL RANGE RESOLUTION ACCURACY* TEST LEADS AC voltage 0 to 250 VAC ± 1 V ± 2% R-T, R-G, T-G (input resistance = 1M Ohm ± 5%) DC voltage 0 to 250 VDC ± 1 V ± 2% R-T, R-G, T-G (input resistance = 1M Ohm ± 5%) Resistance 0 ohm to 999 ohms 1k ohm to 9.9k ohms 10 ohms ± 3% 10k ohms to 99.9k ohms 100 ohm ± 3% 10k ohms to 999k ohms 1k ohm ± 3% 1M ohm to 9.9M ohms 100k ohms ± 3% 10M ohms to 30M ohms 1M ohm ± 10% Active pair: 0 to -60 VDC R-T voltage, 600 ohm to 7k ohms Inactive pair: 0 to -90 VDC R-T voltage, 600 ohms to 1 Megohm 1 ohm ± 5 ohm ± 3% R-T, R-G, T-G 0 – 65 dB 1 dB ±2 dB TR-G Amplitude 0 ± 0.5 dBm R-T Amplitude 0 ± 0.5 dBm R-T Longitudinal balance Precision tone Frequency 404Hz, 1004Hz, 2804Hz (preset) Source Impedance 600 ohms +/- 5% Frequency 8000 – 2MHz (user settable) +/- 10% Source Impedance 100 ohms +/- 5% 577 Hz intermittent trace tone Amplitude 5V P-P *Percent of reading ORDERING INFORMATION PRODUCT NUMBER DESCRIPTION PKG. (LBS.) MIN. ORDER UPC 051115- CE100699624 949ADSL qualification test set 1 each (3.60) 1 each 18042 CE100699632 950ADSL qualification test set w/enhanced testing capability 1 each (3.60) 1 each 18073 CE100700687 AC/DC adapter, 120VAC input 1 each 1 each 19407 CE100700695 Test leads 949/950, red/black/green 1 each 1 each 19408 CE100700711 Serial cable 1 each 1 each 19409 CE100700729 Telephone patch cord 1 each 1 each 19410 CE100700737 Soft carry case 1 each 1 each 19411 CE100700745 Rechargeable NiMH battery pack 1 each 1 each 19412 CE100700752 AC/DC adapter, 220VAC – – – Test, Measurement and Facilities Locating — Diagnostic Testing Equipment FUNCTION 287 3M™ Dynatel™ Advanced Modular System 965AMS The new 965AMS advanced modular system contains every feature of our previous 965 model plus a larger, brighter display that features 3M™ Vikuiti™ Display Enhancement technology, a user-friendly icon-based interface and rugged field-swappable module. The external modules can be shared between technicians and allows transmission testing of a variety of OSP technologies. The platform is available with an optional ADSL2+ modem module. Development for future modules may include such features as: VDSL2, FTTx fiber test, VoIP, DS1, DS3 and new technologies yet to come. 288 www.3MTelecommunications.com 800-426-8688 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS This microcomputer-controlled flexible test set family provides full-featured testing for the triple play—voice, video and data circuits. Because it’s a Dynatel 965 series tester, the AMS model is easy to use, requiring minimal training for testing professionals. And because it emphasizes fault diagnosis and fault location, customer can use the tester to assist in quick problem solving. Autotest The knowledge-based smart autotest function allows automatic test of active and inactive lines with pass/fail limits. Autotest capabilities also include expert system analysis of test results with advice on how to repair or how to locate faults. 3M™ Dynatel Far End Device FED II and customizable selections of tests are supported by the autotest feature of the 965AMS platform. External Modules 965AMS modules support special circuits technicians who work on a variety of circuit standards during a typical day. Because the modules are field swappable, the technicians can share them. The ADSL2+ module is currently available. The following is a list of future modem protocols: VDSL2, FTTx fiber test and VoIP. Rugged, Weather-Resistant Design The hand-held 965AMS product is housed in a lightweight, ergonomically-designed case. The weather-resistant unit weighs only 5 lbs (2.2kg) and operates on a desktop, on the ground, in aerial environments and underground locations. Test, Measurement and Facilities Locating — Diagnostic Testing Equipment The complete testing platform for all outside plant telecommunications. 289 FEATURES BENEFITS 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS Communications Capability to work with a PC or handheld computer supporting software upload and data downloads Flexible architecture Supports various data modem protocols such as ADSL2+ Graphical user interface User-friendly, icon-based display of test results Help function An internal help and tutorial provides information as needed during operation Backlight High resolution/high contrast black and white LCD display Vehicle power adapter Plugs into standard vehicle accessory outlet Windows/CE operating system Provides open architecture software environment Keyboard Allows rapid access to twelve different “blue key” functions, reducing menu levels. Also has cursors, and supports alpha-numeric entry1 Yellow and green LED lights Signal battery state and communication status Software TDR and auto-test knowledge based systems aids technicians during test interpretation Bright big screen Highly visible even in bright sunlight due to proprietary 3M™ Vikuiti™ brightness enhancement technology, 80% larger than 965DSP Modular design All you need is a new module to increase test capability (no need to replace test set) Dynatel yellow Rugged, dependable ACCESSORIES PRODUCT NAME DESCRIPTION Test Leads Five 5-ft (1.5 m) test leads with 2 mm gold-plated banana plugs one end and chrome-plated alligator clips on other end (black/red, blue/yellow, green) Lead styles include bed of nails, no nails, spike and Canadian test leads European Test Leads Five 5-ft (1.5 m) test leads with 2 mm gold-plated banana plugs one end and 4-mm gold-plated banana plugs on other end (black/red, blue/yellow, green) RFL Strap 1.5 ft (0.5 m) with alligator clips on ends AC/DC Adapter 100-250 VAC (50/60 Hz) input, 12 VDC (1 A) output Power cord with IEC socket, US cord included ENVIRONMENTAL SPECIFICATIONS Operating temperature 0° to 140°F (-18 to 60°C) Storage temperature -40° to 165°F (-40 to 75°C) Moisture: rain, water and humidity proof Meets or exceeds 1P65, 1P67 PHYSICAL SPECIFICATIONS 965AMS (includes ADSL2+ module) 290 SIZE (H X W X D) IN. (CM) WEIGHT (INCLUDING BATTERIES) 11.5 x 5.75 x 3.25 (29 x 14.5 x 8.3) 5 LB (2.2 KG) ELECTRICAL SPECIFICATIONS 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS FUNCTION RESOLUTION ACCURACY ± Voltage (DC) 0 to 99.9 V 100 to 300 V 0.1 V 1V 1% ± 0.5 V 3% Voltage (AC) 20 to 4 KHz Meter resistance 100 K or 1 M 0 to 99.9 V 100 to 250 V 0.1 V 1V 1% ± 0.5 V 3% Current 0 to 59.9 mA 60 to 110 mA 430 Ω 0.1 mA 0.1 mA 1% ± 0.3 mA 2% Resistance With CO voltage 0 to 9999 Ω 0 to 9999 Ω 10 k to 99.9 kΩ 100 k to 999 kΩ 1 M to 9.9 MΩ 10 M to 99 MΩ 100 M to 990 MΩ 1Ω 1Ω 0.1 kΩ 1 kΩ 10 kΩ 0.1 MΩ 1 MΩ 1% ± 5 Ω 1% ± 50 Ω 1% 3% 3% 5% 10% Opens (no noise) 0 to 3,000 ft (0 to 1,000 m) 3,000 to 10,000 ft (1 km to 3 km) 10,000 to 50,000 ft (3 km to 15 km) 50,000 to 100,000 ft (15 km to 30 km) 1 ft (1 m) 1 ft (1 m) 10 ft (10 m) 100 ft (100 m) 1% ± 3 ft (1 m) 3% 5% 10% 0 to 20 MΩ 0 to 99.99 Ω 100 to 999.9 Ω 1 k to 3 kΩ — RTS 0.01 Ω RTS 0.1 Ω RTS 1.0 Ω — 0.1% of RTS ± 0.01 Ω 0.2% of RTS ± 0.01 Ω 1.0% of RTS ± 0.01 Ω 0 to 7 kΩ 0 to 3.5 kΩ — — — 5% 0 to 99.9 Ω 100 to 999.9 Ω 1000 to 7000 Ω 0.01 Ω 0.1 Ω 1Ω 0.1% ± 0.01 Ω 0.2% ± 0.01 Ω 1.0% ± 0.01 Ω 0 to 99.99 Ω 0.01 Ω 1% of loop resistance ± 0.01 Ω 200 to 1000 Hz, fixed level 200 to 9999 Hz, -20 to +1 dBm 10 k to 19.99 kHz, -20 to +1 dBm 8 volt peak to peak 1 Hz, 0.1 dB 1 Hz, 0.1 dB +1 Hz 1% Hz, 0.2 dB 2% Hz, 1 dB 0.0 to 4.0 ringer 0 to 2000 nF 0.1 ringer 10 nF Shunt resistance RFL Fault range Resistance to Fault (no noise) Wet section test Loop resistance Resistive balance Loop resistance Resistance difference Tone output ID tone Precision tone- 600 Ω Zout Ringers Load coil count Ground resistance Ohms/distance calculator 0 to 5 1 ±1 load coil 5 to 500 Ω 1Ω 1% ± 1 Ω 0-9999 Ω 0-99999 ft (0-30 km) 0.01 1 ft (0.1 m) — — Note: 1All resistance to fault measurement accuracies have an added factor of (2x10-8) Rf ohms (Rf=fault resistance in ohms) Test, Measurement and Facilities Locating — Diagnostic Testing Equipment RANGE 291 ELECTRICAL SPECIFICATIONS (CON’T FROM PREVIOUS PAGE) 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS FUNCTIONS TDR Ranges Velocity input RANGE RESOLUTION ACCURACY 100 ft, 200 ft, 500 ft, 1,000 ft, 2,000 ft, 5,000 ft, 10,000 ft, 20,000 ft, 30,000 ft (30 m, 60 m, 150 m, 300 m, 600 m, 1.5 km, 3km, 6 km, 10 km) 1 ft (1 m) * 0.3% range 5 nS, 34 nS, 135 nS, 1600 nS, 600 nS Fixed values 0.50 to 0.99 (150 to 299 m/µs) — — Single trace, dual trace, differential, memory, crosstalk, Peak, memory diff. — — Loss (and frequency) With 600 Ω Zin -40 to +10 dBm, 200 to 3000 Hz, -40 to +10 dBm, 3000 to 9995 Hz, -40 to +10 dBm, 10 k to 19.9 kHz 0.1 dB, 1 Hz, 0.1 dB, 10 Hz 1 dB, 10 Hz ± 0.5 dB, 2 Hz ± 0.5 dB, 10 Hz ± 1 dB, 20 Hz Noise metallic 600 Ω Zin C and psophometric 0 to 50 dBrnc (-90 to –40 dBm0p) 1 dB ± 2 dB Noise to ground 600 Ω Zin 40 to 100 dBrnc (-50 to 10 dBm0p) 1 dB ± 2 dB 0 to 85 dB 1 dB ± 2 dB DTMF, Pulse Standard Standard Date, time, number, name -4 to –32 dBm — 1 dBm ± 2 dBm Short range wideband specifications (without SA option) Wideband loss 100, 135 Ω Zin Wideband tone output–100,135 Ω Zout -50 to +2 dBm, 20 kHz to 1.2 MHz .1 dB, 100 Hz ± 2 dB, 1% Hz 0 dBm, 20 k to 2.2 MHz 1 kHz ± 1 dB at 2.2 MHz SA wideband specifications Wideband loss 100, 135 Ω Zin -85 to +5 dBm, 20 kHz to 2.2 MHz .1 dB, 100 Hz ± 1 dB, 1%Hz E filter 10-90 dBm F filter 20-90 dBm G filter 30-90 dBm 1 dB 1 dB 1 dB ± 2 dB ± 2 dB ± 2 dB 10 kHz to 2.2 MHz – 90 dBm to +10 dBm 0.5% of span 1dB 1% 0 dBm, 20 k to 2.2 MHz 1 kHz ± 1 dB at 2.2 MHz ± 0.1% frequency ± 0.5 kHz 1-60 minutes 1 minute ±5% Lower limits: 30 dBrnC and E 40 dBrnF 50 dBrnG 100 dBrn upper limit All 30 dB higher for N to Ground 1 dB ±1 dB (typical) 9999 1 — Modes Longitudinal balance Dial mode Caller ID (U.S. and Canada only) Carrier level Wideband noise metallic 100, 135 Ω Zin E, F, G, and G2 filters Wideband spectral analysis 100, 135 Ω Zin Dynamic Range Wideband tone output–100,135 Ω Zout Impulse noise counting E, F, G, and G2 filters Counting interval Threshold Count capacity 292 www.3MTelecommunications.com 800-426-8688 ELECTRICAL SPECIFICATIONS 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS RANGE Filters: C and Psophometric E filter F filter G filter G2 filter 300 Hz – 3400 Hz 1 kHz – 50 kHz 4.9 kHz – 245 kHz 20 kHz – 1.1 MHz – 3 dB points 20 kHz – 2.2 MHz GENERAL SPECIFICATIONS Drop test Survives 3 ft (1 m) drop onto concrete, using ASTM D4169 assurance level I method 5276 Vibration Meets Mil 810F method 514.5 Water, dust and chemical proof Meets IP65 per IEC 529(1989) for rain and dust Immersion test IP67 0.15 m deep Emissions Standards meet FCC part 15, class A: Digital Devices for the US, and EN55022 (radiated emissions) Built to ISO9001/2000 certification for manufacturing facilities and TL9000 compliant Built to ANSI/IPC A610-C manufacturing standards Language English, Spanish, and French Canadian* Units Feet or meters, Fahrenheit or Celsius, dBrnC or dBm0p, m/uS or Vf Battery Rechargeable battery pack or alkaline, 9 hours typical use (50% on/off measures voltage) Display 4.1" x 3.1"(104 x 79 mm), 320 x 240 pixel resolution, high visibility in bright sunlight due to 3M™ Vikuiti™ film technology Stored results (All results) 100 results total of all types maximum Note: Routine lab calibration is not recommended or required *Available late 2005 FEATURES MODEL NAME 965AMS BASIC 965AMS TDR 965AMS TDR+SA 965AMS BASIC+ADSL2+ • • • • • 965AMS BASIC TDR+ADSL2+ 965AMS SA+ADSL2+ FEATURES Basic VOM and POTS • TDR Short range wideband loss/tone Wideband spectrum analysis + loss/tone ADSL2+ modem • • • • • • • • • • • • • Test, Measurement and Facilities Locating — Diagnostic Testing Equipment FUNCTIONS 293 FEATURES 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS Interconnectivity All modules include RS232 Communicates with a PC using a supplied cable USB active synch client 1.1 Includes required USB cables Battery charger port Test lead connectors 294 Basic VOM All versions have these features Voltage Detects and measures the presence of central office (exchange) or foreign DC or AC voltages, including ringer voltages Current Measures DC loop current with a 430-ohm shunt Resistance Measures conductor and insulation resistance up to 1GigaOhms Soak test High voltage extended period resistance measurement that will expose corrosion-induced faults Opens Locates opens at distances up to 100,000 ft. (30 km) Resistive fault location Displays distance to fault Special resistance Measures the loop resistance and the resistance difference between two conductors on a pair Wet section test Allows RFL measurement when both wires in a pair are faulted and there is no separate good pair available Ringers Measures and displays capacitance associated with one or more ringers and the equivalent count Ground resistance Measures the resistance of the ground path ID tone High power interrupted signal for tracing and identification Kick test Rapid, fast combination of resistance, voltage and opens for quickly evaluating cable pairs Voice band tests Noise, loss, tone, longitudinal balance, load coil counting and FED compatibility Load coil count Indicates the presence of load coils in a loop circuit and distance to the first load coil Loss Measures voiceband loss Noise Measures noise metallic and noise to ground in dBrnC or dBm0p Longitudinal balance Provides active measurement of line balance Level trace Measures and displays the impedance of the un-terminated line as a function of frequency Tone Provides test tones for conductor identification and transmission testing. 10 default tones, user selectable. Voiceband to 20 kHz, ID tones to 1000 Hz Autotest Supports 3M Dynatel Far End Device FED II Dialing Offhook, dialing capability, monitoring capability Microphone and speaker capability Speaker has 1-watt power output for noisy environments Caller ID functionality Displays number, name, date, and time just like the customers callbox Wideband shortrange testing Wideband loss with limited range, wideband tone. This feature set is enabled in the basic and TDR units. Wideband loss measurements for short range or low frequency Test impendance 135 ohms only Tone 20kHz to 1.2MHz at OdBm www.3MTelecommunications.com 800-426-8688 OPTIONAL FEATURES 3M™ DYNATEL™ ADVANCED MODULAR SYSTEM 965AMS Full-featured TDR with user-selectable pulse widths, length, gain zoom, filter and Vp. The TDR feature is enabled in the TDR and SA models Single trace Provides graphical representation of events on a pair. Including expert system analysis of trace results Dual trace Allows active comparison of two traces Differential Displays difference between two circuits Crosstalk Displays the crosstalk from one pair to another Memory Allows comparison of an active trace with a trace stored in memory Memory diff Difference between memory and live trace Peak Displays a history of maximum and minimum values with the live trace WideBand tests Wideband loss, wideband noise, wideband tone, spectrum analyzer this feature set is enabled in the SA models WideBand Continuous sine wave insertion loss and noise measurements Test impedances 100 and 135 Wideband loss Loss measurements to 2.2 MHz for pre-qualifying xDSL Tone 20 kHz to 2.2 MHz at 0dBm E, F, G, G2 filter Weighted noise and impulse noise counting ORDERING INFORMATION PRODUCT NUMBER STOCK NUMBER 965AMS-TDR/SA/ADSL2+/AC/DC/BON 80-6113-1614-4 965AMS-TDR/SA/ADSL2+/AC/DC/NN 80-6113-1660-7 For ordering information, please contact your local 3M representative. KIT COMPONENTS 965AMS BASIC 965AMS Basic 965AMS base unit storage bag, blue, yellow, green, red and black test leads. Conductor strap, NiMH battery pack (packed in unit), alkaline battery holder, wire gauge, self test circuit board and chain bead, 110/220V AC adapter, certificate of calibration, vehicle power adapter, instruction manual, warranty card, quick reference cards, USB cable and ethernet cable (with ASDL2 options). Test, Measurement and Facilities Locating — Diagnostic Testing Equipment TDR 295 296 www.3MTelecommunications.com 800-426-8688