ESL-Spectrum 1591 N Harding Street Indianapolis IN 46202 Phone: (317) 951-2300 Fax: (317) 951-2310 Date: Jan 26, 2016 Job Name IndyGo - Facility Upgrades Project INDY16-44005 Indianapolis IN Bid Date Feb 10, 2016 Submittal Date Jan 26, 2016 Engineer: Parsons Brinckerhoff 300 N Meridian St Indianapolis IN 46204 Date: Jan 26, 2016 Page 1/1 Transmittal Project IndyGo - Facility Upgrades Project INDY16-44005 Quote# Location Indianapolis IN Contact: ESL-Spectrum 1591 N Harding Street Indianapolis IN 46202 Phone: (317) 951-2300 From: Scott Parkinson ATTACHED WE ARE SENDING YOU 1 COPY OF THE FOLLOWING ITEM: Drawings Specifications Other: Prints Information Plans Submittals THESE ARE TRANSMITTED FOR: Prior Approval Approval Approval as Submitted Approval as Noted Type FF00009 Resubmittal for Approval Corrections Your Use Review and Comment Record Bids due on: Other: MFG Part B C F1 F2 F3 F4 G H K M N P P1 Columbia Lighting Columbia Lighting Beacon Products Beacon Products Kim Lighting, Inc. Kim Lighting, Inc. Columbia Lighting Kurtzon Lighting Prescolite Columbia Lighting Hubbell Lighting, Inc. Hubbell Lighting, Inc. Hubbell Lighting, Inc. S1 W1 Beacon Products W2 W3 Beacon Products Beacon Products LXEM4-50LW-RFA-EU LCL4-50ML-EU-CHSC AL/X-60NB/136-5K-6X6-UNV-SF3-X AL/X-24NB/55-5K-2X2-UNV-SF3-X ARFX25WF-5K-45-UV-DB-X EL700F3/7L5KUV/X LBIL4-40ML-EDU-ELL14 WL-LP-X-2-40-X/LEDR40-UNV LC6LED-277-6LCLED-6-40K-8-B24 LJT14-40HLG-FAA12-EDU NRG-406-2 HBLHO-72LU-A2-5K-W-092-CD-X HBLHO-72LU-A2-5K-W-092-CD-XOCS360 TRV/X-24NB/27-5K-T3-UNV-DBT A670TSRLED991/480WB/4ARC45T3/ MDL03/SRR1HSS/BKT TRV/X-48NB/110-5K-T3-UNV-PEC-DBT TRV/X-48NB/110-5K-T3-UNV-DBT Sternberg Vintage Lighting Page 1/1 Catalog Number: LXEM4-50LW-RFA-EU Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: B Notes: INDY16-44005 LXEM Enclosed and Gasketed Fiberglass Extreme Environment / LED PROJECT INFORMATION FEATURES • • • • • • • • • • • • • • • • • • • • • • LED Enclosed and Gasketed Long life 60,000 hour LEDs at L80 for reduced maintenance Four LED color choices and 80 CRI IP66 all sizes when ordered with standard polyacetal (POM) latches IP65 all sizes, IP67 4' and 8' Available in 2', 4', or 8' lengths Fiberglass housing with F1 weatherability rating, standard Smooth housing for easy cleaning Gasket is non-porous to ensure seal Impact modified acrylic lens equivalent to 100% DR Wide range of lens selections Lens firmly secured with tamper resistance ready polyacetal (POM) latches Stainless steel latching optional Removable gear tray electrical access for modular replaceability Emergency battery pack installed, optional on most models Standard ambient -20°C to 25°C Elevated ambient option on most models DesignLights Consortium® qualified Includes surface mounting brackets Occupancy and/or daylight sensing accessories available Available with exclusive wiHUBB technology preinstalled Five year warranty Project Name Type Catalog No. Date CONSTRUCTION Housing is formed from UL 5VA fiberglass. F1 weatherability rating, suitable for indoor or outdoor use with respect to exposure to UV light. Pour-in-place non-porous gasketing assures seal. LED affixed to removable heat sinked gear tray. 14 Latches per 8', 8 per 4', 6 per 2'. Latches are provided tamper resistance ready, tamper resistant screws by others. Latches are standard polyacetal (POM), optional in stainless steel. Access openings are provided for electrical connection. SHIELDING Lineal ribbed frosted acrylic lens impact modified equivalent to 100% DR; modification adds flexibility to reduce impact breakage compared to standard acrylic formulations. Optional ribbed polycarbonate lens or deep acrylic. All lenses available in clear or frost. ELECTRICAL Long-life LEDs are rated for 60,000 hours at L80 lumen maintenance. Extra High Lumen packages (XL) rated L70 at 60,000 hours. Driver options include fixed output for on/off function, step dimming4 (high/low/off) or continuous 0-10V dimming. QR code label affixed to housing for easy traceability. CERTIFICATION All luminaires are built to UL 1598 and 2108 standards, and bear appropriate CSA labels. Ingress protection IP65 and IP67 standard. UL Sanitation certified. Wet location labeling is standard. Emergency-equipped fixtures built to UL 924. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. WARRANTY Five year warranty (Terms and Conditions Apply). FINISH White painted parts are treated with a five-stage phosphate bonding process and finished with high reflectance baked enamel. ORDERING INFORMATION LXEM EXAMPLE LXEM4-35HL-RFA-EDU – MODEL – COLOR TEMP LXEM LED Enclosed and Gasketed 30 35 40 50 SIZE 2 2' 1,2,6,7 4 4' 8 8' 3000K 3500K 4000K 5000K LUMEN OUTPUT LW ML HL VL XL SHIELDING RFA RA DFA DCA RFP Low Watt Medium Lumen High Lumen1 Very High Lumen Xtra High Lumen2, 5 SENSOR KITS (Order Separately) All sensor kits include Occupancy & Daylight. Daylight activation requires setting of dip-switches on site. Catalog # # Relays Lens Type Voltage Wet Label OS1360WLK 1 360° 120/277 Yes 120V/ OS2360WLK 2 360° 120/277 Yes 277V OS1AWLK 1 Aisle 120/277 Yes OS2AWLK 2 Aisle 120/277 Yes HL not available in 2' size with HT option. Not available with battery pack. 3 2' and 4' only. 8' not available. 4 Only available on 4' and 8' LW and ML Lumen package. Not available with HT. Not available with XL lumen package. Not available with VL lumen package. 8 Requires 3⁄8" OD threaded rod by others. 9 2 required for 8' fixture 1 5 2 6 Page 1/3 Rev. 08/11/15 7 U – Ribbed Frosted Acrylic Ribbed Clear Acrylic Deep Frosted Acrylic Deep Clear Acrylic Ribbed Frosted Polycarbonate3 DRIVER – VOLTAGE E Fixed Output ESD Step Dimming4,5 ED 0-10V Dimming U 120V-277V PRODUCT AVAILABILITY Size 2' 4' 8' Lumen Package Nominal Lumen Range (DFA Lens) Nominal Watts Lumens/ Watt (Highest) Max Temp, HT Option LW ML HL LW ML HL VL XL LW ML HL VL XL 3150-3500 4300-4750 4850-5350 4050-4450 4850-5350 5800-6400 7350-8150 9750-10750 8100-8900 9700-10700 11600-12800 14700-16300 19500-21500 29 43 51 36 47 52 68 102 72 94 104 136 204 121 110 105 124 114 123 120 105 124 114 123 120 105 40°C 40°C 25°C 50°C 50°C 45°C 40°C 25°C 50°C 50°C 45°C 40°C 25°C Lumens vary according to color temperatures and other factors. See specific photometric test(s). Output levels based on the DFA lens option. © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com OPTIONS GLR Fast Blow Fuse SSL Stainless Steel Tamper Resistance Ready Latches TP Tamper Proof Latches ELL14 Emergency Battery Pack Installed, 1400 Lumens6 F3C8W 3 Wire 8' Wet Cord F3C15W 3 Wire 15' Wet Cord SWH Single Wet Hub 1⁄2" NPT Hub DWH Dual Wet Hub 1⁄2" NPT Hub XEDPM Dual Pendant Brackets (pendant by others)8 WIH wiHUBB Enabled HT Elevated Ambient 1,2,6 ACCESSORIES (ORDER SEPARATELY) XEHC Chain Hanger Kit (Includes 14" Chain) XE45MB 45° Mounting Bracket9 XE45MBSS 45° Stainless Steel Mounting Bracket LED / LXEM Catalog Number: LXEM4-50LW-RFA-EU Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: B Notes: INDY16-44005 LXEM Enclosed and Gasketed Fiberglass Extreme Environment / LED PHOTOMETRIC DATA LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet Test 14.00242 Test Date 8/29/14 ZONAL LUMEN SUMMARY LXEM4-40ML-DFA-EU LXEM LED Enclosed and Gasketed, Industrial. 7" x 51" LED with deep frosted acrylic diffuser D15CC55UNVTC 1.00 LED 5383 47.00 Surface 0º = 90 90º = 90 0º = 1.25 90º = 1.30 Length: 4.25 Width: 0.50 Height: 0.33 Zone 0-30 INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 1297 24.1 24.1 0-40 2127 39.5 39.5 0-60 3824 71.0 71.0 0-90 5105 94.8 94.8 0-180 5383 100.0 100.0 180 165 150 135 1700 120 850 105 90 ENERGY DATA Total Luminaire Efficiency 100% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 115 75 850 Noncompliant $2.09 based on 3000 hrs. and $0.08 per KWH 60 1700 0 0.0 15 30 Horiz 0-180 45.0 45 90.0 Test 14.00117 Test Date 9/9/14 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet ZONAL LUMEN SUMMARY LXEM4-40HL-DFA-EU LXEM LED Enclosed and Gasketed, Industrial 7" x 51" LED with deep frost ribbed acrylic diffuser D15CC55UNVTC 1.00 LED 6182 51.80 Surface 0º = 90 90º = 90 0º = 1.25 90º = 1.29 Length: 4.17 Width: 0.50 Height: 0.29 Zone 0-30 INDOOR CANDELA PLOT Lumens % Lamp % Fixt. 1493 24.2 24.2 0-40 2450 39.6 39.6 0-60 4399 71.2 71.2 0-90 5863 94.8 94.8 0-180 6182 100.0 100.0 180 165 150 135 2000 120 1000 105 ENERGY DATA 90 Total Luminaire Efficiency 100% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 119 Noncompliant $2.02 based on 3000 hrs. and $0.08 per KWH 75 1000 60 2000 0 0.0 15 30 Horiz 0-180 45.0 45 90.0 Test 14.00224 Test Date 8/29/14 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet ZONAL LUMEN SUMMARY LXEM4-40VL-DFA-EU LXEM LED Enclosed and Gasketed, Industrial 7" x 51" LED with deep frosted acrylic diffuser D23CC90UNVTF 1.00 LED 7876 67.70 Surface 0º = 90 90º = 90 0º = 1.24 90º = 1.29 Length: 4.25 Width: 0.50 Height: 0.25 Zone 0-30 Lumens % Lamp % Fixt. 1899 24.1 24.1 39.5 0-40 3114 39.5 0-60 5588 71.0 71.0 0-90 7461 94.7 94.7 0-180 7876 100.0 100.0 INDOOR CANDELA PLOT 180 165 150 135 2600 120 1300 105 ENERGY DATA Total Luminaire Efficiency 100% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 116 Noncompliant 90 75 1300 $2.07 based on 3000 hrs. and $0.08 per KWH 60 2600 0 Page 2/3 Rev. 08/11/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com 0.0 15 30 Horiz 0-180 45.0 45 90.0 LED / LXEM Catalog Number: LXEM4-50LW-RFA-EU Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: B Notes: INDY16-44005 LXEM Enclosed and Gasketed Fiberglass Extreme Environment / LED DIMENSIONAL DATA See Table 67⁄9" 67⁄9" 22⁄5" 22⁄5" 55⁄8" 43⁄8" RFA Lens: 2', 4', 8', RFP Lens: 2', 4' LXEM LENGTH DIMENSIONS SIZE LENS LENGTH 2' RFA RFP DFA 272⁄3" 272⁄3" 272⁄3" DFA Lens: 2', 4', 8' SIZE LENS LENGTH 4' RFA RFP DFA 512⁄3" 512⁄3" 512⁄3" SIZE LENS LENGTH 8' RFA RFP DFA 100" N/A 100" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 3/3 Rev. 08/11/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / LXEM Catalog Number: LCL4-50ML-EU-CHSC Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: C Notes: INDY16-44005 LCL Lensed Striplight / LED PROJECT INFORMATION • • • • • • • • • • • • Type Catalog No. Date CONSTRUCTION FEATURES • • • • • Project Name LED technology in a lensed striplight Long life 50,000 hour LEDs at L80 for reduced maintenance Up to 110 lumens per watt Choice of four LED color temperatures Superior color consistency within a 3-step MacAdam ellipse and greater than 80 CRI Choice of four lumen packages per size Available in 2', 4' or 8' lengths Optional integral emergency battery pack Heavy die-formed steel channel with 100% acrylic formed diffuser Fully assembled fixture for quick installation LED boards and driver accessible for future maintenance or upgrades Modular replaceable LED components Surface mount or suspended Maximum temperature 35°C on all lumen packages up to HL DesignLights Consortium® (DLC) qualified Five year warranty Maximum temperature 35 (degree) C on all lumen packages up to HL MODEL SIZE 2 2' 4 4' 8 8' COLOR TEMP 30 35 40 50 3000K 3500K 4000K 5000K All luminaires are built to UL 1598 and 2108 standards, and bear appropriate CSA c/US labels. Damp location labeling is standard. Emergency equipped fixtures labeled UL924. Adheres to LM70, LM80, and TM21 industry standards. Designlights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www. designlights.org. FINISH White painted parts are treated with a five-stage phosphate bonding process and finished with high reflectance baked enamel. For a post-painted housing finish select PAF option. WARRANTY Five year warranty (Terms and Conditions apply). ELECTRICAL Long-life LEDs are rated for 50,000 hours at L80 lumen maintenance. Driver options include fixed output for on/off function, step dimming (high/low/ off) or continuous 0-10V dimming. ORDERING INFORMATION – LCL LCL LED Striplight CERTIFICATION Housing, wireway, and ends are formed from code-gauge steel. Housing components act as heat sink for LED heat dissipation. Knockouts are provided for electrical access and mounting. Shielded with 100% frosted prismatic acrylic lens. EXAMPLE LCL4-40HL-EU U – LUMEN OUTPUT LW ML HL VL Low Watt Medium Lumen High Lumen Very High Lumen See Product Availability Table below. DRIVER E ESD ED ED1 Fixed Output Step Dimming 0-10V Dimming 0-10V 1% Dimming LUTH Lutron H Series3 LUT5 Lutron 5 Series3 ACCESSORIES (ORDER SEPARATELY) S18 SS18 CSHC LCLWG4 18" Stem, Canopy 18" Swivel Stem—45° Swivel Chain Hanger Assembly 4' Wire Guard, 2 Required for 8' Fixture VOLTAGE U 120V-277V 347 347V (E,ED,ED1 only) For compatibility with Dual-Lite LiteGear® inverters in lieu of installed battery pack, contact Hubbell Lighting representative. Not available in 2 ft size. 3 Not available in VL packages. 2 Page 1/2 Rev. 12/23/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com OPTIONS ELL14 Emergency Battery Pack, 1400 Lumens1,2 GLR Fast Blow Fuse PAF Paint After Fabrication NYC NYC Compliant PRODUCT AVAILABILITY SIZE 2' 4' 8' 1 – LUMEN PACKAGE ML LW ML HL VL LW ML HL VL NOMINAL LUMENS (4000K) 2,500 2,500 5,000 6,100 10,100 5,000 10,100 12,200 20,100 NOMINAL EFFICACY WATTS 25 100 25 100 48 104 55 110 96 105 48 104 96 105 111 110 193 104 Lumens vary according to color temperature and other factors. See specific photometric test(s). LED / LCL Catalog Number: LCL4-50ML-EU-CHSC Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: C Notes: INDY16-44005 LCL Lensed Striplight / LED PHOTOMETRIC DATA Test ITL15383 Test Date 7/14/14 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY LCL4-40HL-ED LCL Led Lensed Utility Channel, Industrial 48" x 41⁄2 x 313⁄16" LED with acrylic formed lens D15CC55UNVTC 1.00 LED 6078 54.70 0º = 90 90º = 90 0º = 1.24 90º = 1.28 Length: 4.00 Width: 0.40 Height: 0.00 Zone Lumens Lamp Fixt. 0-30 0-40 0-60 0-90 0-180 1649 2679 4574 5860 6078 27.1 44.1 75.2 96.4 100.0 27.1 44.1 75.2 96.4 100.0 180 165 150 135 2200 120 1100 ENERGY DATA 105 Total Luminaire Efficiency 100.0 Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 111 Noncompliant $2.16 based on 3000 hrs. and $0.08 per KWH 90 75 1100 60 2200 15 0 0.0 30 Horiz 0-180 45.0 45 90.0 DIMENSIONAL DATA 96" 45⁄8" A 3" A B 48" B A B A B A A 41⁄2" 41⁄8" 48" 45⁄8" A 3" A B 241⁄8" A A 45⁄8" 191⁄8" A B 36" A 313⁄16" B A A - 7/8" Diameter Knockout B - 5⁄16" x 1⁄2" hole Note 1: All Non-Shielded (strip) fixtures- Deduct 1/16" from overall dimension for continuous row mounting. Dimensions shown include end panel. MOUNTING ACCESSORIES CSZT 11/2" Space CSTH Slide Clamp Tong Hanger NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 12/23/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / LCL Catalog Number: AL/X-60NB/136-5K-6X6-UNVSF3-X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: F1 Notes: INDY16-44005 Type: rev. 06.10.2015 Project Name: ALPHA (LED) Alpha Floodlight Max Weight: 27.0 lbs Max EPA: 1.32 sq ft Notes: design . performance . technology www.beaconproducts.com Sample AL-U Ordering 60NB-136 / 5K / A B 4X4 UNV / PEC / C D / E DETAILS PM / F G A. MODEL 16 3/8” 11 5/8 ” 14 5/8 ” 26 1/2” 14 5/8 ” I F. ELECTRICAL OPTIONS PEC AL-U Alpha, up light PCR-TL photocell, twist-lock 1,3 PCR-SC photocell, shorting cap 1,3 2PF dual power feed 1,2 photocell, button 24NB-55 55 Watts - LED array 36NB-80 80 Watts - LED array G. MOUNTING OPTIONS 60NB-136 136 Watts - LED array WM wall mount 72NB-170 170 Watts - LED array PM 3” pier mount 72NB-220 220 Watts - LED array SF3 2 3/8” OD tenon (std.) H. SHIELD OPTIONS 11 3/4” C. CCT - COLOR TEMP FL full louver 3K 3000K FV full visor 4K 4000K HL half louver 5K 5000K (std.) HV half visor 2X2 narrow spot I. COLOR 4X4 narrow flood BBT basic black textured 5X5 medium flood BMT black matte textured 6X6 wide flood WHT white textured 5X3 horizontal flood MBT metallic bronze textured 3X5 vertical flood BZT bronze textured DBT dark bronze textured GYS gray smooth DPS dark platinum smooth D. BEAM 8” Wall Mount (WM) SHIELD OPTIONS Full Louver H Alpha, down light 20” Standard SF3 mount Slips 2 3/8” to 3” O.D. Tenon BBT / AL-D B. ENGINE-WATTS 9 3/8” FL / Full Visor E. VOLTAGE UNV 120-277V GNT green textured 347 347V MST metallic silver textured 480 480V MTT metallic titanium textured OWI old world iron RAL ______________ MOUNTING OPTIONS 11 3/4” 1/2” Half Visor 16 3/8 ” 1 1/2” 6 1/2” Half Louver 8” 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 1 not available @ 347V or 480V input 2 available on 24NB-55, 72NB-170, and 72NB-220 only 3 PCR-TL and PCR-SC not available on AL-U Fax: (941) 751-5535 ORDERING Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: AL/X-60NB/136-5K-6X6-UNVSF3-X Type: F1 Notes: INDY16-44005 rev. 06.10.2015 ALPHA (LED) Alpha Floodlight Max Weight: 27.0 lbs Max EPA: 1.32 sq ft design . performance . technology Intended Use: The Alpha Luminaire is a high performance “LED” energy and maintenance lighting solution, designed with optical versatility. Markets include large areas requiring perimeter lighting, security fence lighting, truck terminals, car lots, recreational sports lighting, airport ramp lighting and building flood-lighting. The Alpha LED luminaire is intended to be used to reduce energy and maintenance associated with HID legacy lighting technology. Construction: The housing, electrical compartment and fitter are made from die cast aluminum that is pre-treated and powder-coated to meet the most rugged industry standards. The finish is corrosion resistant to meet ASTMB-117, resists cracking or loss of adhesion per ASTM D522, resists surface impacts of up to 160 inch-pound. All external hardware is corrosion resistant. Adjustable cast knuckle: The adjustable knuckle is designed to slip fit 2 3/8” to 3” O.D. tenon. The knuckle is designed for continuous aiming adjustment without the use is cast serrations. The cast knuckle uses cast external degree markers for aiming. The aiming adjustment is design to operate with a single bolt adjustment. The Alpha can adjust 30-degrees up from Nadir to straight up vertical. corrosion resistance and resists cracking or loss of adhesion per ASTM D522 and resists surface impacts of up to 160 inch-pound. Agency Certification: The luminaire shall bear a CSA label and be marked suitable for wet locations. Warranty: Beacon luminaires feature a 5 year limited warranty. Beacon LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED drivers are covered by a 5 year limited warranty. PIR sensors carry a 5 year limited warranty from the sensor manufacturer. See Warranty Information on www.beaconproducts.com complete details and exclusions. Power/Lumens & Distributions D. Delivered Lumens LPW Engine Beam Angle Field Angle Max Candela 24NB 17.4 H x 17.2 V 32.3 H x 32.5 V 45,920 55 2x2 5,680 104.5 36NB 17.4 H x 17.2 V 32.3 H x 32.5 V 68,881 80 2x2 8,520 104.5 60NB 17.4 H x 17.2 V 32.3 H x 32.5 V 114,802 136 2x2 14,200 104.5 72NB 17.4 H x 17.2 V 32.3 H x 32.5 V 137,673 170 2x2 17,029 100 72NB 17.4 H x 17.2 V 32.3 H x 32.5 V 164,385 220 2x2 20,333 96.2 24NB 28.1 H x 29.4 V 52.4 H x 51.8 V 18,255 55 4x4 5,627 103.8 36NB 28.1 H x 29.4 V 52.4 H x 51.8 V 27,383 80 4x4 8,440 103.7 60NB 28.1 H x 29.4 V 52.4 H x 51.8 V 46,635 136 4x4 14,066 103.7 72NB 28.1 H x 29.4 V 52.4 H x 51.8 V 54,762 170 4x4 17,039 100 72NB 28.1 H x 29.4 V 52.4 H x 51.8 V 65,349 220 4x4 20,143 95.3 24NB 66.8 H x 67.3 V 97.0 H x 96.3 V 8,342 55 5x5 5,042 91.7 36NB 66.8 H x 67.3 V 97.0 H x 96.3 V 12,514 80 5x5 7,563 92.3 60NB 66.8 H x 67.3 V 97.0 H x 96.3 V 20,856 136 5x5 12,605 92.8 72NB 66.8 H x 67.3 V 97.0 H x 96.3 V 13,347 170 5x5 16,107 95 72NB 66.8 H x 67.3 V 97.0 H x 96.3 V 30,024 220 5x5 18,146 82.5 24NB 72.0 H x 74.9 V 102.2 H x 101.6 V 4,449 55 6x6 5,603 101.8 36NB 72.0 H x 74.9 V 102.2 H x 101.6 V 6,674 80 6x6 8,404 102.5 60NB 72.0 H x 74.9 V 102.2 H x 101.6 V 11,123 136 6x6 14,024 103.3 72NB 72.0 H x 74.9 V 102.2 H x 101.6 V 13,347 170 6x6 17,315 102 72NB 72.0 H x 74.9 V 102.2 H x 101.6 V 16,089 220 6x6 20,260 92.1 Fasteners: All fasteners shall be stainless steel. When tamper resistant fasteners are required, spanner HD (snake eye) style shall be provided (special tool required, consult factory). 24NB 56.2 H x 22.7 V 82.3 H x 46.4 V 8,342 55 5x3 5,032 91.6 36NB 56.2 H x 22.7 V 82.3 H x 46.4 V 12,514 80 5x3 7,547 92.3 60NB 56.2 H x 22.7 V 82.3 H x 46.4 V 20,856 136 5x3 12,579 93 Drivers: Luminaires are equipped with an LED driver that accepts 100V through 277V, 50 Hz to 60 Hz (UNV), or a driver that accepts 347V or 480V input. Power factor is .92 at full load. All electrical components are rated at 50,000 hours at full load and 40-C ambient conditions per MIL-217F Notice 2. Optional 0 to 10 volt dimming drivers are available upon request. Component-to -component wiring within the luminaire will carry no more than 80% of rated current and is listed by UL for use at 600VAC at 50°C or higher. Plug disconnects are listed by UL for use at 600 VAC. 72NB 56.2 H x 22.7 V 82.3 H x 46.4 V 25,027 170 5x3 15,126 89 72NB 56.2 H x 22.7 V 82.3 H x 46.4 V 30,024 220 5x3 18,108 82.5 24NB 22.8 H x 56.1 V 46.7 H x 83.8 V 8,342 55 3x5 5,042 91.6 36NB 22.8 H x 56.1 V 46.7 H x 83.8 V 12,514 80 3x5 7,566 92.3 60NB 22.8 H x 56.1 V 46.7 H x 83.8 V 20,856 136 3x5 12,611 93 Surge Protector: The on-board surge protector shall be a UL recognized component for the United States and Canada and have a surge current rating of 20,000 Amps using the industry standard 8/20 pSec wave. The LSP shall have a clamping voltage of 320V and surge rating of 372J. The case shall be a high-temperature, flame resistant plastic enclosure. 72NB 22.8 H x 56.1 V 46.7 H x 83.8 V 25,027 170 3x5 15,126 89 72NB 22.8 H x 56.1 V 46.7 H x 83.8 V 30,024 220 3x5 18,153 82.5 Electrical Assembly: The fixture electrical compartment shall contain all LED driver components and shall be provided with an internal terminal block for AC power connections. The compartment is designed for an optional twist lock photo control. Optical: The Alpha luminaire provides the best combination of vertical and horizontal illumination while reducing light behind the poles. The Alpha features revolutionary individual LED optical control based on TIR high performance acrylic optical designs. Flood Lighting optics are available in 2x2, 4x4, 5x5, 6x6, 5x3 and 3x5 NEMA distributions and are interchangeable with Type 2, 3,4, and Type V roadway and area lighting optics. The Alpha also features a protective lens cover. Well designed optics result in fewer poles and fixtures that use less energy consumption, while improved light distribution result in lower life-cycle cost as well as initial installation costs. Lifeshield™ Circuit: Thermal circuit shall protect the luminaire from excessive temperature by interfacing with its 0-10V dimmable drivers to reduce drive current as necessary. The factory-preset temperature limits shall be designed to ensure maximum hours of operation to assure L70 lumen maintenance. The device shall activate at a specific, factory-preset temperature, and progressively reduce power over a finite temperature range and may be reliably operated in any ambient temperature up to 55ºC (131 ºF). Operation shall be smooth and undetectable to the eye. Thermal circuit shall directly measure the temperature at the LED solder point. For maximum simplicity and reliability, the device shall have no dedicated enclosure, circuit board, wiring harness, gaskets, or hardware. Device shall have no moving parts, and shall operate entirely at low voltage (NEC Class 2). Thermal circuit shall be designed to “fail on”, allowing the luminaire to revert to full power in the event of an interruption of its power supply, or faulty wiring connection to the drivers. Device shall be able to co-exist with other 0-10V control devices (occupancy sensors, external dimmers, etc.). The device will effectively control the solder point temperature as needed; otherwise it will allow the other control device(s) to function unimpeded. Watts Optic TM21 is the framework for taking LM-80 data and making useful LED lifetime projections. Reported and Calculated Lifetimes shown are based on hours at the time of this printing. For current Reported and Calculated hours please contact factory or Beacon’s web-site. Operating Environment: Shall be able to operate normally in ambient temperatures from -40°C to 40°C CCT (COLOR TEMP) Lumen Output Multipliers CRI (Color Rendering) Finish: Finish shall be a Beacote V polyester powder-coat electro-statically applied and thermocured. Beacote V finish shall consist of a five stage iron phosphate chemical pretreatment regimen with a polymer primer sealer, oven dry off, and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for 5000° K = 1.0 min 67 CRI 4000° K = .92 min 70 CRI 3000° K = .75 min 80 CRI 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. Fax: (941) 751-5535 SPECIFICATION Catalog Number: Type: AL/X-24NB/55-5K-2X2-UNV-SF3X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Notes: F2 INDY16-44005 Type: rev. 06.10.2015 Project Name: ALPHA (LED) Alpha Floodlight Max Weight: 27.0 lbs Max EPA: 1.32 sq ft Notes: design . performance . technology www.beaconproducts.com Sample AL-U Ordering 60NB-136 / 5K / A B 4X4 UNV / PEC / C D / E DETAILS PM / F G A. MODEL 16 3/8” 11 5/8 ” 14 5/8 ” 26 1/2” 14 5/8 ” I F. ELECTRICAL OPTIONS PEC AL-U Alpha, up light PCR-TL photocell, twist-lock 1,3 PCR-SC photocell, shorting cap 1,3 2PF dual power feed 1,2 photocell, button 24NB-55 55 Watts - LED array 36NB-80 80 Watts - LED array G. MOUNTING OPTIONS 60NB-136 136 Watts - LED array WM wall mount 72NB-170 170 Watts - LED array PM 3” pier mount 72NB-220 220 Watts - LED array SF3 2 3/8” OD tenon (std.) H. SHIELD OPTIONS 11 3/4” C. CCT - COLOR TEMP FL full louver 3K 3000K FV full visor 4K 4000K HL half louver 5K 5000K (std.) HV half visor 2X2 narrow spot I. COLOR 4X4 narrow flood BBT basic black textured 5X5 medium flood BMT black matte textured 6X6 wide flood WHT white textured 5X3 horizontal flood MBT metallic bronze textured 3X5 vertical flood BZT bronze textured DBT dark bronze textured GYS gray smooth DPS dark platinum smooth D. BEAM 8” Wall Mount (WM) SHIELD OPTIONS Full Louver H Alpha, down light 20” Standard SF3 mount Slips 2 3/8” to 3” O.D. Tenon BBT / AL-D B. ENGINE-WATTS 9 3/8” FL / Full Visor E. VOLTAGE UNV 120-277V GNT green textured 347 347V MST metallic silver textured 480 480V MTT metallic titanium textured OWI old world iron RAL ______________ MOUNTING OPTIONS 11 3/4” 1/2” Half Visor 16 3/8 ” 1 1/2” 6 1/2” Half Louver 8” 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 1 not available @ 347V or 480V input 2 available on 24NB-55, 72NB-170, and 72NB-220 only 3 PCR-TL and PCR-SC not available on AL-U Fax: (941) 751-5535 ORDERING Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: Type: AL/X-24NB/55-5K-2X2-UNV-SF3X Notes: F2 INDY16-44005 rev. 06.10.2015 ALPHA (LED) Alpha Floodlight Max Weight: 27.0 lbs Max EPA: 1.32 sq ft design . performance . technology Intended Use: The Alpha Luminaire is a high performance “LED” energy and maintenance lighting solution, designed with optical versatility. Markets include large areas requiring perimeter lighting, security fence lighting, truck terminals, car lots, recreational sports lighting, airport ramp lighting and building flood-lighting. The Alpha LED luminaire is intended to be used to reduce energy and maintenance associated with HID legacy lighting technology. Construction: The housing, electrical compartment and fitter are made from die cast aluminum that is pre-treated and powder-coated to meet the most rugged industry standards. The finish is corrosion resistant to meet ASTMB-117, resists cracking or loss of adhesion per ASTM D522, resists surface impacts of up to 160 inch-pound. All external hardware is corrosion resistant. Adjustable cast knuckle: The adjustable knuckle is designed to slip fit 2 3/8” to 3” O.D. tenon. The knuckle is designed for continuous aiming adjustment without the use is cast serrations. The cast knuckle uses cast external degree markers for aiming. The aiming adjustment is design to operate with a single bolt adjustment. The Alpha can adjust 30-degrees up from Nadir to straight up vertical. corrosion resistance and resists cracking or loss of adhesion per ASTM D522 and resists surface impacts of up to 160 inch-pound. Agency Certification: The luminaire shall bear a CSA label and be marked suitable for wet locations. Warranty: Beacon luminaires feature a 5 year limited warranty. Beacon LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED drivers are covered by a 5 year limited warranty. PIR sensors carry a 5 year limited warranty from the sensor manufacturer. See Warranty Information on www.beaconproducts.com complete details and exclusions. Power/Lumens & Distributions D. Delivered Lumens LPW Engine Beam Angle Field Angle Max Candela 24NB 17.4 H x 17.2 V 32.3 H x 32.5 V 45,920 55 2x2 5,680 104.5 36NB 17.4 H x 17.2 V 32.3 H x 32.5 V 68,881 80 2x2 8,520 104.5 60NB 17.4 H x 17.2 V 32.3 H x 32.5 V 114,802 136 2x2 14,200 104.5 72NB 17.4 H x 17.2 V 32.3 H x 32.5 V 137,673 170 2x2 17,029 100 72NB 17.4 H x 17.2 V 32.3 H x 32.5 V 164,385 220 2x2 20,333 96.2 24NB 28.1 H x 29.4 V 52.4 H x 51.8 V 18,255 55 4x4 5,627 103.8 36NB 28.1 H x 29.4 V 52.4 H x 51.8 V 27,383 80 4x4 8,440 103.7 60NB 28.1 H x 29.4 V 52.4 H x 51.8 V 46,635 136 4x4 14,066 103.7 72NB 28.1 H x 29.4 V 52.4 H x 51.8 V 54,762 170 4x4 17,039 100 72NB 28.1 H x 29.4 V 52.4 H x 51.8 V 65,349 220 4x4 20,143 95.3 24NB 66.8 H x 67.3 V 97.0 H x 96.3 V 8,342 55 5x5 5,042 91.7 36NB 66.8 H x 67.3 V 97.0 H x 96.3 V 12,514 80 5x5 7,563 92.3 60NB 66.8 H x 67.3 V 97.0 H x 96.3 V 20,856 136 5x5 12,605 92.8 72NB 66.8 H x 67.3 V 97.0 H x 96.3 V 13,347 170 5x5 16,107 95 72NB 66.8 H x 67.3 V 97.0 H x 96.3 V 30,024 220 5x5 18,146 82.5 24NB 72.0 H x 74.9 V 102.2 H x 101.6 V 4,449 55 6x6 5,603 101.8 36NB 72.0 H x 74.9 V 102.2 H x 101.6 V 6,674 80 6x6 8,404 102.5 60NB 72.0 H x 74.9 V 102.2 H x 101.6 V 11,123 136 6x6 14,024 103.3 72NB 72.0 H x 74.9 V 102.2 H x 101.6 V 13,347 170 6x6 17,315 102 72NB 72.0 H x 74.9 V 102.2 H x 101.6 V 16,089 220 6x6 20,260 92.1 Fasteners: All fasteners shall be stainless steel. When tamper resistant fasteners are required, spanner HD (snake eye) style shall be provided (special tool required, consult factory). 24NB 56.2 H x 22.7 V 82.3 H x 46.4 V 8,342 55 5x3 5,032 91.6 36NB 56.2 H x 22.7 V 82.3 H x 46.4 V 12,514 80 5x3 7,547 92.3 60NB 56.2 H x 22.7 V 82.3 H x 46.4 V 20,856 136 5x3 12,579 93 Drivers: Luminaires are equipped with an LED driver that accepts 100V through 277V, 50 Hz to 60 Hz (UNV), or a driver that accepts 347V or 480V input. Power factor is .92 at full load. All electrical components are rated at 50,000 hours at full load and 40-C ambient conditions per MIL-217F Notice 2. Optional 0 to 10 volt dimming drivers are available upon request. Component-to -component wiring within the luminaire will carry no more than 80% of rated current and is listed by UL for use at 600VAC at 50°C or higher. Plug disconnects are listed by UL for use at 600 VAC. 72NB 56.2 H x 22.7 V 82.3 H x 46.4 V 25,027 170 5x3 15,126 89 72NB 56.2 H x 22.7 V 82.3 H x 46.4 V 30,024 220 5x3 18,108 82.5 24NB 22.8 H x 56.1 V 46.7 H x 83.8 V 8,342 55 3x5 5,042 91.6 36NB 22.8 H x 56.1 V 46.7 H x 83.8 V 12,514 80 3x5 7,566 92.3 60NB 22.8 H x 56.1 V 46.7 H x 83.8 V 20,856 136 3x5 12,611 93 Surge Protector: The on-board surge protector shall be a UL recognized component for the United States and Canada and have a surge current rating of 20,000 Amps using the industry standard 8/20 pSec wave. The LSP shall have a clamping voltage of 320V and surge rating of 372J. The case shall be a high-temperature, flame resistant plastic enclosure. 72NB 22.8 H x 56.1 V 46.7 H x 83.8 V 25,027 170 3x5 15,126 89 72NB 22.8 H x 56.1 V 46.7 H x 83.8 V 30,024 220 3x5 18,153 82.5 Electrical Assembly: The fixture electrical compartment shall contain all LED driver components and shall be provided with an internal terminal block for AC power connections. The compartment is designed for an optional twist lock photo control. Optical: The Alpha luminaire provides the best combination of vertical and horizontal illumination while reducing light behind the poles. The Alpha features revolutionary individual LED optical control based on TIR high performance acrylic optical designs. Flood Lighting optics are available in 2x2, 4x4, 5x5, 6x6, 5x3 and 3x5 NEMA distributions and are interchangeable with Type 2, 3,4, and Type V roadway and area lighting optics. The Alpha also features a protective lens cover. Well designed optics result in fewer poles and fixtures that use less energy consumption, while improved light distribution result in lower life-cycle cost as well as initial installation costs. Lifeshield™ Circuit: Thermal circuit shall protect the luminaire from excessive temperature by interfacing with its 0-10V dimmable drivers to reduce drive current as necessary. The factory-preset temperature limits shall be designed to ensure maximum hours of operation to assure L70 lumen maintenance. The device shall activate at a specific, factory-preset temperature, and progressively reduce power over a finite temperature range and may be reliably operated in any ambient temperature up to 55ºC (131 ºF). Operation shall be smooth and undetectable to the eye. Thermal circuit shall directly measure the temperature at the LED solder point. For maximum simplicity and reliability, the device shall have no dedicated enclosure, circuit board, wiring harness, gaskets, or hardware. Device shall have no moving parts, and shall operate entirely at low voltage (NEC Class 2). Thermal circuit shall be designed to “fail on”, allowing the luminaire to revert to full power in the event of an interruption of its power supply, or faulty wiring connection to the drivers. Device shall be able to co-exist with other 0-10V control devices (occupancy sensors, external dimmers, etc.). The device will effectively control the solder point temperature as needed; otherwise it will allow the other control device(s) to function unimpeded. Watts Optic TM21 is the framework for taking LM-80 data and making useful LED lifetime projections. Reported and Calculated Lifetimes shown are based on hours at the time of this printing. For current Reported and Calculated hours please contact factory or Beacon’s web-site. Operating Environment: Shall be able to operate normally in ambient temperatures from -40°C to 40°C CCT (COLOR TEMP) Lumen Output Multipliers CRI (Color Rendering) Finish: Finish shall be a Beacote V polyester powder-coat electro-statically applied and thermocured. Beacote V finish shall consist of a five stage iron phosphate chemical pretreatment regimen with a polymer primer sealer, oven dry off, and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for 5000° K = 1.0 min 67 CRI 4000° K = .92 min 70 CRI 3000° K = .75 min 80 CRI 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 Due to our continued efforts to improve our products, product specifications are subject to change without notice. Fax: (941) 751-5535 SPECIFICATION Catalog Number: ARFX25WF-5K-45-UV-DB-X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: F3 Notes: INDY16-44005 ARFX25 ArcheType ® Flood Luminaire kl_arfx25_spec.pdf 20” JOB TYPE NOTES APPROVALS 20” FEATURES ■ Independently aimed LEAR™ modules 20” distribution creation 355° horizontal and 70° vertical module ■ adjustment and -5° to +25° housing adjustment ■ Certifications ■ Design software interface for custom Variable drive current ■ IP66 sealed optical chamber ■ Traditional NEMA distributions available 20” 9” SPECIFICATIONS 26-5/8” ARFX25 Max Weight = 64 lbs. EPA = 1.51 20” 9” 7.482” 20” 26-5/8” 6-1/2” 7.482” Side Front 9” Bottom ORDERING CODE ARFX25 26-5/8” Fixture Distribution WF Wide Flood VF Vertical Flood MF Medium Flood NF Narrow Flood Color Temperature 3K 3000K 4K 4000K 5K 5000K Electrical Module Drive Current 35 40 45 50 55 60 7.482” NS Narrow Spot SP Spot X Custom1 350mA 400mA 450mA 500mA 550mA 600mA 6-1/2” Controls Wireless WIR-RMS-IO 208 240 277 WIR-RML-IO 208 240 277 Motion Voltages UV 120-277V 347 347V 480 480V Fuse Options Fixture Finish Photocell Options SG Stealth Gray A25-7H Horizontal3 SF 120, 277, 347 Line Volts BL Black A25-7V Vertical3 DF 208, 240, 480 Line Volts DB Dark Bronze A30 120V LG Light Gray A31 208V PS Platinum Silver A32 240V WH White CC Custom Color2 A33 277V A34 347V A35 480V For Pole Spec Select: http://www.kimlighting.com/products/arms_and_poles/ For Control Spec Select: http://trpssl.com/index.html SCL-R Round Pole-Mounted Occupancy 1 SCL-S Square Pole-Mounted Occupancy Sensor up to 16" 3 Sensor up to 16" 6-1/2” 2 Custom distributions must include IES# file where indicated Custom colors supject to additional charges, minimum quantites and extended lead times. Consult representative. Indicates mount position of fixture. SCH-R Round Pole-Mounted Occupancy Sensor up to 30" SCH-S Square Pole-Mounted Occupancy Sensor up to 30" Kim Lighting reserves the right to change specifications without notice. © 2015 KIM LIGHTING | 16555 East Gale Ave. | City of Industry | CA 91745 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev May 2015 | 1 | Catalog Number: ARFX25WF-5K-45-UV-DB-X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: F3 Notes: INDY16-44005 ARFX25 ArcheType ® Flood Luminaire kl_arfx25_spec.pdf ARFX LEAR™ 5x5 FLOOD Distribution Type 3000K Field Angle - 10% max 350 mA 400 mA 450 mA 500 mA 550 mA 600 mA WF - Wide Flood (°H X °V) 14774 16884 18995 23638 23216 25326 VF - Vertical Flood (°H X °V) 14425 16486 18547 23081 22668 24729 MF - Medium Flood 15440 17645 19851 24703 24262 26468 15090 17246 19402 24145 23714 25869 (°H X °V) NF - Narrow Flood (°H X °V) Designation 400 mA 450 mA 500 mA 550 mA 600 mA WF - Wide Flood (°H X °V) 17236 19698 22160 27577 27085 29547 VF - Vertical Flood (°H X °V) 16830 19234 21638 26927 26447 28851 MF - Medium Flood 18013 20586 23159 28820 28306 30879 17606 20121 22636 28169 27666 30181 (°H X °V) NF - Narrow Flood (°H X °V) Distribution Type 350 mA 400 mA 450 mA 500 mA 550 mA 600 mA 17588 20100 22613 28140 27638 30150 VF - Vertical Flood (°H X °V) 17173 19626 22080 27477 26986 29440 MF - Medium Flood 18380 21006 23632 29409 28883 31509 17965 20531 23098 28744 28231 30797 (°H X °V) NF - Narrow Flood (°H X °V) ELECTRICAL CHARACTERISTICS Ordering Code ARFX25 System Watts Line Voltage VAC 120 277 480 350 mA 170 1.42 0.61 N/A 400 mA 194 1.62 0.88 N/A 450 mA 219 1.82 0.79 N/A 500 mA 243 2.03 0.88 N/A 120-480 Hz Amps AC 50/60 550 mA 267 2.23 0.96 N/A 600 mA 292 2.43 1.05 N/A TM-21 LIFETIME CALCULATION LEAR™ >65 1.78 Drive Current WF - Wide Flood (°H X °V) Optical System >80 1.33 CRI Minimum S/P Ratio 5K 5000K Delivered Lumens - 219C pro-rate Field Angle - 10% max LEAR™ 3000K Drive Current 350 mA Optical System Spectroradiometric 4K 4000K >70 1.66 3K Delivered Lumens - 219C pro-rate Field Angle - 10% max 4000K Consult factory for Amber, Turtle Friendly, Gulf Coast and Observatory applications. Drive Current Distribution Type 5000K LED COLOR Delivered Lumens - 219C pro-rate Ordering Code ARFX25 Ambient Environment °C 16 Min. Max THD Dimming Power (%) Range Factor >0.9 20 10% to 100% Projected Lumen Maintenance 26 TM-21 60 100 15° 98 97 96 94 25° 40° 96 96 95 95 93 93 90 90 Dimming Source current out of 0-10V purple wire Absolute voltage range on 0-10V (+) purple wire Min Typical Max Min Typical Max 0mA - 2mA 0 - 12V Reported L70 >60Khrs Kim Lighting reserves the right to change specifications without notice. © 2015 KIM LIGHTING | 16555 East Gale Ave. | City of Industry | CA 91745 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev May 2015 | 2 | Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: ARFX25WF-5K-45-UV-DB-X Type: F3 Notes: INDY16-44005 ARFX25 ArcheType ® Flood Luminaire kl_arfx25_spec.pdf SPECIFICATIONS Housing: Electrical Components: Finish: ■ Low copper aluminum alloy die-casting ■ Standard programmable driver for variable ade and abrasion resistant, electrostatically ■ F designed as one-piece with external cooling ribs. ■ Solid cast aluminum walls between the housing and arm creating a thermal barrier between the optical and electrical compartments. ■ M olded silicone gasket throughout to insure sealing between the two compartments and ingress protection. H ousing designed with integral Type X ■ thermal transfer “turrets” utilized for both thermal transfer and secure location of the LEAR™ Optical Module. The turrets are spaced in rows of 3 X 3, designed to optimize photometric performance for standard and Type X custom distributions. Lens Frame: ■ One-piece die-cast, low copper aluminum alloy secured to housing with eight captive, tamper-resistant stainless steel fasteners. ■ Molded silicone gasket assembles into a cast channel in the doorframe sealing the 3/16” thick low iron-content, tempered glass lens against the housing upon closure. drive current settings from 350mA to 600mA. molded silicon gasket seal to separate from the optical chamber. Type X LEAR™ Optical Module: protecting the sensitive electronics and acting as a signal for maintenance. ■ Programmable Driver is rated for -40°F starting. ■ “Thermal Shield” Primary Side thermister Protection for sustainable life of LEAR modules and electronic components. Dimming: Dimming range from 10% to 100% by the use of its standard 0-10V interface on the programmable driver. ■ IP66 sealed Type X LEAR modules utilize six high output LEDs, positioned beneath a precision, high purity molded acrylic prism U L 8750 Standard for Safety for Light ■ Emitting Diode (LED) Equipment for use in Lighting Products. ■ C SA C22.2#250.0 Luminaires. A NSI C136.31-2010 3G Vibration tested and ■ compliant ■ R CM/CE/SASO certifications pending. Consult factory for specific details. ■ R oHS compliant. ■ Modular wiring harness in the service ■ Dimming circuitry compatible with 0-10V CAUTION: ■ F ixtures must be grounded in accordance area provided for user access to the dimming circuitry. user-defined control devices. Arm: ■ Low copper aluminum alloy, two piece die- casting designed and gasketed to function as one-piece. ■ with national, state and/or local electrical codes, Failure to do so may result in serious personal injury. WARRANTY: ■ F or full warranty see http://www. hubbelllighting.com/resources/warranty External cooling ribs create continuous aesthetic and thermal path ■ Molded silicone gasket seals the wiring channel seperating the arm from the housing thermally insulating the electronic components. IES files created using design software vertical adjustment with a tamper resistant fastener. L 1598 Standard for Luminaires. ■ U ■ M eets Buy American provisions within ARRA. ■ Customer factory adjusted distributions using ■ Tooless 355° horizontal adjustment and 70° Certifications and Listings: ■ ■ Optimized standard distribution or custom beam patterns. Dark Bronze, (WH) White, (PS) Platinum Silver, (SG) Stealth Gray, (LG) Light Gray, and (CC) Custom Color (Include RAL#). series circuited. ■ Open circuit fault will extinguish the luminaire ■ Turret alignment and thermal transfer design allow for freedom of adjustability and precision of the LEAR™ LED array. ■ S tandard colors include (BL) Black, (DB) ■ 10KV Transient voltage/surge suppression ■ IP66 construction to protect the interior components from dust and water ingress. applied, thermally cured, triglycida isocyanurate (TGIC) polyester powdercoat. ■ Electrical components are located in the arm ■ Internally accessible slip-fitter provided to attach to a 1-1/4” to 2-3/8” tenon with handsfree wiring and maintenance. ■ Luminaire housing adjustable +30° and -5 via locking fastener under the arm cover. ■ Targeted optics minimize pixilation concerns to provide outstanding performance, uniformity and glare control. Kim Lighting reserves the right to change specifications without notice. © 2015 KIM LIGHTING | 16555 East Gale Ave. | City of Industry | CA 91745 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev May 2015 | 3 | Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: ARFX25WF-5K-45-UV-DB-X Notes: Type: F3 INDY16-44005 ARFX25 ArcheType ® Flood Luminaire kl_arfx25_spec.pdf Controls A25-7H or V4 Fully gasketed 7-pin receptacle standard. Easy access location above the electrical compartment. 7-pin construction allows user-defined interface and control definition of operational performance. ANSI twist-lock control module by-others. H (Horizontal) or V (Vertical) indicates mount position of fixture. Round Pole-Mounted Occupancy Sensor up to 16' SCL-R Round Pole Mounted Occupancy Sensor up to 16’ - Outdoor occupancy sensor with 0-10V interface dimming control mounts directly to the pole. Wide 360° pattern. Module colors available Black, Gray, and White. Module is cut for round pole mounting. Pole diameter needed. Pole to be drilled in the field with provided installation instructions. Ordering Example: SCL-R41/2772 /BL 3 Square Pole-Mounted Occupancy Sensor up to 16' SCL-S Square Pole Mounted Occupancy Sensor up to 16’ - Outdoor occupancy sensor with 0-10V interface dimming control mounts directly to the pole. Wide 360° pattern. Module colors available Black, Gray, and White. Module is cut for square pole mounting. Pole diameter needed. Pole to be drilled in the field with provided installation instructions. Ordering Example: SCL-L/2772 /BL 3 Round Pole-Mounted Occupancy Sensor up to 30’ SCH-R Round Pole Mounted Occupancy Sensor up to 30’ - Outdoor occupancy sensor with 0-10V interface dimming control mounts directly to the pole. Wide 360° pattern. Module colors available Black, Gray, and White. Module is cut for round pole mounting. Pole diameter needed. Pole to be drilled in the field with provided installation instructions. Ordering Example: SCH-R41/2772 /BL 3 Wireless Control WIR-RMS WIR-RML WIR-RMS-IO WIR-RML-IO Hubbell Building Automation’s wiSCAPE™ Fixture Module is a bidirectional wireless RF device that allows an individual fixture to be managed, monitored and metered. The wiSCAPE Fixture Modules communicates wirelessly over a robust 2.4GHz ISM (Industrial, Scientific and Medical) certified meshed radio signal. The wiSCAPE Fixture Module drastically simplifies control and automation of projects, especially in retrofit environments and challenges the legacy world of wired-systems. wiSCAPE wireless control technology adapts easily to complex automation situations for quick, simple and economical commissioning. Photocell4 Factory installed photocell inside housing with a fully gasketed sensor on the side wall. For multiple fixture mountings, one fixture is supplied with a photocell to operate the others. Square Pole-Mounted Occupancy Sensor up to 30' SCH-S Square Pole Mounted Occupancy Sensor up to 30’ - Outdoor occupancy sensor with 0-10V interface dimming control mounts directly to the pole. Wide 360° pattern. Module colors available Black, Gray, and White. Module is cut for square pole mounting. Ordering Example: SCH-S/2772 /BL 3 1 Pole Diameter, 2Voltage, 3 Color, 4 Not compatible with wiSCAPE. Kim Lighting reserves the right to change specifications without notice. © 2015 KIM LIGHTING | 16555 East Gale Ave. | City of Industry | CA 91745 P 626.968.5666 | F 626.369.2695 | www.kimlighting.com | Rev May 2015 | 4 | Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: EL700F3/7L5KUV/X Type: F4 Notes: INDY16-44005 Scarab EL700 TM 120 to 277 Volt Die-Cast Aluminum LED 9/5/13 • kl_el700led_spec.pdf Approvals: Type: Job: Fixture Catalog number: Fixture Options: Fixture and Finish Ordered separately from fixture, see page 3. See 120 Volt Mounting Options Spec Sheet for mounting options Specifications Date: Page: 1 of 4 Housing: Die-cast aluminum body and lens frame. Swivel: Die-cast aluminum with locking teeth and K" solid brass NPT mount. Provides horizontal rotation independent of the threaded mount. Swivel locked by J-20 stainless set screw. Clear anodized prior to powder coating for added corrosion resistance. EL700/7L 7 Light Emitting Diodes 7K" (191 mm) 6D"r. 4K" 3D" Gasketing: Silicone gaskets throughout. Fasteners: Stainless steel. Wiring: No. 18AWM rated 105°C. (114 mm) (92 mm) K" NPT Optical System: High performance acrylic optic securely attached to internal heat sink for maximum thermal dissipation. 2B" Driver: Universal Voltage from 120 to 277V with a ±10% tolerance. -40ºF. starting temperature. All drivers are Underwriters Laboratories recognized. (54 mm) EL700/9L 9 Light Emitting Diodes 9" (229 mm) 8"r. 5B" 4M" (130 mm) (110 mm) K" NPT Finish: Each luminaire receives a fade and abrasion resistant, electrostatically applied, thermally cured, triglycidal isocyanurate (TGIC) polyester powdercoat finish. Standard colors include (BL) Black, (DB) Dark Bronze, (GR) Verde Green. Listed to: UL 1598 Standard for Luminaires - UL 8750 Standard for Safety for Light Emitting Diode (LED) Equipment for use in Lighting Products and CAN/CSA C22.2 No. 250.0 -08 Luminaires. LEDs and drivers are RoHS compliant. CAUTION: Fixtures must be grounded in accordance with national, state and/or local electrical codes, Failure to do so may result in serious personal injury. 2B" (54 mm) EL700/12L 12 Light Emitting Diodes 10M" 9K"r. (262 mm) 6K" 5D" (165 mm) (143 mm) K" NPT 2B" (54 mm) U.s. patent D424,731 KIM LIGHTING RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE. © 2013 KIM LIGHTING INC. • p.o. Box 60080, City of Industry, CA 91716-0080 • TEL: 626/968-5666 • FAX: 626/369-2695 Catalog Number: EL700F3/7L5KUV/X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: F4 Notes: INDY16-44005 Scarab EL700 TM 120 to 277 Volt Die-Cast Aluminum LED 9/5/13 • kl_el700led_spec.pdf Type: Job: Page: 2 of 4 Standard Features Ordering Information Fixture l l l l l l l l l l l l l l l l l l 1 Source EL700S3/7L3KUV 1 EL700S3/7L4KUV 1 EL700S3/7L5KUV 1 EL700F3/7L3KUV 1 EL700F3/7L4KUV 1 EL700F3/7L5KUV 9W, 9W, 9W, 9W, 9W, 9W, EL700S3/9L3KUV 1 EL700S3/9L4KUV 1 EL700S3/9L5KUV 1 EL700F3/9L3KUV 1 EL700F3/9L4KUV 1 EL700F3/9L5KUV 11W, 11W, 11W, 11W, 11W, 11W, 9 9 9 9 9 9 EL700S3/12L3KUV 1 EL700S3/12L4KUV 1 EL700S3/12L5KUV 1 EL700F3/12L3KUV 1 EL700F3/12L4KUV 1 EL700F3/12L5KUV 14W, 14W, 14W, 14W, 14W, 14W, 12 12 12 12 12 12 1 1 7 7 7 7 7 7 LEDs, LEDs, LEDs, LEDs, LEDs, LEDs, 3000K 4200K 5100K 3000K 4200K 5100K LEDs, LEDs, LEDs, LEDs, LEDs, LEDs, 3000K 4200K 5100K 3000K 4200K 5100K LEDs, LEDs, LEDs, LEDs, LEDs, LEDs, 3000K 4200K 5100K 3000K 4200K 5100K 1 S = Spot, F = Narrow Flood, 3 = 350mA, UV = Universal Voltage from 120 to 277V with a ±10% tolerance. Finish TGIC powder coat. Color: Black Cat. No.: BL Dark Bronze DB Verde Green GR © 2013 KIM LIGHTING INC. • p.o. Box 60080, City of Industry, CA 91716-0080 • TEL: 626/968-5666 • FAX: 626/369-2695 Catalog Number: EL700F3/7L5KUV/X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: F4 Notes: INDY16-44005 Scarab EL700 TM 120 to 277 Volt Die-Cast Aluminum LED 9/5/13 • kl_el700led_spec.pdf Type: Job: Page: 3 of 4 Fixture Options Ordered Separately from Fixture Aluminum Adjustable Glare Shield Spun aluminum shield with 45° cut and drain hole. Includes die-cast low copper alloy (< 0.6%) aluminum lens ring. The shield is rotatable 360°. Replaces standard lens ring/hood on fixture. 31° cutoff (87 mm) Finish Black Dark Bronze Verde Green Aluminum Full Glare Shield 32° cutoff 31.5° cutoff 3N" DIA. 4A" DIA. (91 mm) 5N" 4F" DIA. DIA. (106 mm) (103 mm) (145 mm) EL700/9L l AGS73BL l AGS73DB l AGS73GR EL700/12L l AGS74BL l AGS74DB l AGS74GR 6D" 31° cutoff 3G" DIA. (87 mm) Finish Black Dark Bronze Verde Green EL700/7L l FGS72BL l FGS72DB l FGS72GR 8L"5A" (222 mm) 4M" 31.5° cutoff 32° cutoff 3N" DIA. 5N" DIA. 4F" DIA. 4A" DIA. (91 mm) (106 mm) (103 mm) (141 mm) EL700/9L l FGS73BL l FGS73DB l FGS73GR 6L" (172 mm) (129 mm) (168 mm) (110 mm) (143 mm) EL700/12L l FGS74BL l FGS74DB l FGS74GR 5H" DIA. (145 mm) l No Option l No Option l No Option Stainless steel wire screen welded to flange, and held in place with spring clips. Screen inserts inside full glare shield only. All debris screens are black iridite colored. 8L" 6D"4M" (110 mm) 5D" (143 mm) Finish Black Mounting l No Option l No Option l No Option Spun aluminum shield with drain hole. Includes die-cast low copper aluminum lens ring. Replaces standard lens ring/hood on fixture. 5D" Debris Screen (172 mm) 5H" DIA. (141 mm) EL700/7L l AGS72BL l AGS72DB l AGS72GR 6L" (129 mm) (110 mm) (143 mm) 3G" DIA. 8L" (222 mm) 5A" 6D" 4M" (168 mm) 5D" EL700/7L l DS72 31° cutoff EL700/9L l DS73 3G" DIA. (87 mm) 5A" (222 mm) (129 mm) (168 mm) EL700/12L 31.5° cutoff 3N" DIA. 4A" DIA. (91 mm) l DS74 (103 mm) 32° cutoff 4F" DIA. 5N" DIA. l No Option (141 mm)(106 mm) Refer to 120 Volt Mounting Options Spec Sheet http://www.kimlighting.com/content/products/specs/specs_files/kl_120vmounting_spec.pdf for individual mounting options. © 2013 KIM LIGHTING INC. • p.o. Box 60080, City of Industry, CA 91716-0080 • TEL: 626/968-5666 • FAX: 626/369-2695 5H" DI (145 mm) Catalog Number: EL700F3/7L5KUV/X Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: F4 Notes: INDY16-44005 Scarab EL700 TM 120 to 277 Volt Die-Cast Aluminum LED 9/5/13 • kl_el700led_spec.pdf Type: Job: Page: 4 of 4 Lumen Data Spectroradiometric 3000K 2800 to 3175K ≤80 >.90 @ 120V Correlated Color Temp. CCT (K) Color Rendering Index (CRI) Power Factor 4200K 3800 to 4600K ≤80 >.90 @ 120V 5100K 4600 to 5600K ≤70 >.90 @ 120V Electrical Drive Current EL700-7L Current EL700-9L EL700-12L Volts -AC Amps - AC System Watts Volts -AC Amps - AC System Watts Volts -AC Amps - AC System Watts 120 0.08 9 120 0.09 11 120 0.13 14 208 0.05 9 208 0.06 11 208 0.08 14 240 0.04 9 240 0.05 11 240 0.07 14 277 0.04 9 277 0.04 11 277 0.06 14 350mA Absolute Lumens EL700-7L Current 350mA EL700-9L EL700-12L Temp. Spot Narrow Flood Temp. Spot Narrow Flood Temp. Spot 3000K 806 502 3000K 1031 714 3000K 1334 Narrow Flood 918 4200K 1047 661 4200K 1339 939 4200K 1778 1208 5100K 1173 741 5100K 1500 1024 5100K 1938 1317 Main Beam Candela and Beam Angle EL700-7L Current Temp. 350mA Spot Beam° EL700-9L Narrow Flood Beam° Temp. Spot Beam° EL700-12L Narrow Flood Beam° Temp. Spot Beam° Narrow Flood Beam° 3000K 5553 15° 1170 35° 3000K 6499 15° 3134 35° 3000K 9528 15° 3782 35° 4200K 7214 15° 1544 35° 4200K 8441 15° 4121 35° 4200K 12699 15° 4977 35° 5100K 8082 15° 1730 35° 5100K 9456 15° 4494 35° 5100K 13842 15° 5426 35° LED performance and lumen output continues to improve at a rapid pace. Log onto www.kimlighting.com to download the most current photometric files from Kim Lighting’s IES File Library. For custom optics and color temperature configurations, contact factory. Projected Lumen Maintenance TM21-11* 100,000 hrs Calulated (L70) .97 .96 1,003,000 hrs * 60,000 hrs, 350mA, Ts 46-51°C / 25°C ambient. © 2013 KIM LIGHTING INC. • p.o. Box 60080, City of Industry, CA 91716-0080 • TEL: 626/968-5666 • FAX: 626/369-2695 Catalog Number: LBIL4-40ML-EDU-ELL14 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: G Notes: INDY16-44005 LBIL LED Bi-Level Luminaire with Controls PROJECT INFORMATION Project Name Type Catalog No. Date HOUSING CERTIFICATION Steel fixture body. ELECTRICAL FEATURES • • • • • • • • • • Energy saving luminaire with integrated occupancy controls Long-life 50,000 hour LEDs at L70 for reduced maintenance Choice of four lumen packages Occupancy controlled dimming of the LEDs increases energy savings while maintaining base light levels in stairwells at all times Tool-less access to ballast for ease of maintenance Can be surface mounted, wall mounted, or suspended Fail safe operation switches light level to 100% if sensor is damaged Optional battery backup available for emergency egress applications DesignLights Consortium® (DLC) qualified 5 year warranty (terms and conditions apply) Long-life LEDs are rated for 50,000 hours at L70 lumen maintenance. Driver options include fixed output for on/off function, step dimming (high/low/ off), or continuous 0-10V dimming. LENS Highly efficient acrylic lens with a linear refractive pattern for even illumination and excellent LED obscuration. All luminaires are built to UL1598 and 2108 standards, and bear appropriate CSA labels. Damp location labeling is standard. Emergency equipped fixtures labeled UL924. Adheres to LM79, LM80 and TM21 standards. Designlights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. WARRANTY 5 year warranty (terms and conditions apply). OCCUPANCY SENSOR Hubbell Building Automation Internally mounted Passive Infrared Occupancy sensor. LED indicator for easy verification of coverage. Lens has a 1500 square-foot, 360° coverage area at a mounting height of 10 ft, and a 2:1 radius to height ratio coverage pattern. Sensor includes an adjustable time delay, and motion/photocell sensitivity time delay, and motion/photocell sensitivity. ORDERING INFORMATION 4 LBIL MODEL – SIZE LBIL LED Bi-Level Luminaire EXAMPLE LBIL4-35LW-EDU COLOR TEMP 2 2' 4 4' 8 8' U – LUMEN OUTPUT 35 3500K 40 4000K 50 5000K VW MW LW ML Very Low Watt (2' only) Medium Low Watt (2' only) Low Watt Medium Lumen DRIVER VOLTAGE OPTIONS E Fixed Output ESD Step Dimming ED 0-01V Dimming U 120V-277V ELL14 Emergency Battery Pack Installed, 1400 Lumens NYC NYC Compliant NYCU NYC Compliant, Union Label C6TL15_ 6' Cord and Twist-Lock™ Plug 15A (Add Voltage: 1=120, 2=277) C6TL20_ 6' Cord and Twist-Lock™ Plug 20A (Add Voltage: 1=120, 2=277) C6P151 6' Cord and Straight Blade Plug 15A, 120V PRODUCT AVAILABILITY, 100% LIGHT OUTPUT Size 2' 4' 8' Lumen Package Nominal Lumens Nominal Watts Efficacy VW MW LW LW ML LW ML 1,600 2,000 3,000 3,000 5,000 6,000 10,000 16 21 28 31 51 62 102 99 97 105 98 96 98 96 – Page 1/2 Rev. 12/03/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com SURFACE / LBIL Catalog Number: LBIL4-40ML-EDU-ELL14 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: G Notes: INDY16-44005 LBIL LED Bi-Level Luminaire with Controls PHOTOMETRIC DATA Test #L04134338 Test Date 4/17/13 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet INDOOR CANDELA PLOT LBIL-4-40ML-EU LBIL Led Bi-Level Luminaire, Surface 55"L. X 6"W. X 4-1/2"H. LED luminaire, white reflector, and diffused lens. D310CQ50UNVA-A 1.00 LED 5276 50.40 Surface 0º = 90 90º = 90 0º = 1.19 90º = 1.28 Length: 4.00 Width: 0.38 Height: 0.17 180 165 150 ENERGY DATA 135 1700 120 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 105 Noncompliant $2.26 based on 3000 hrs. and $0.08 per KWH 850 ZONAL LUMEN SUMMARY 105 Zone 90 75 850 Lumens % Lamp % Fixt. 0-30 1271 24.1 24.1 0-40 2073 39.3 39.3 0-60 3635 68.9 68.9 0-90 4939 93.6 93.6 0-180 5276 100.0 100.0 60 1700 0 0.0 15 30 Horiz 0-180 45.0 45 90.0 DIMENSIONAL DATA 6" 4" 54" 0.88" 6" 10" 54" 6" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 12/03/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com SURFACE / LBIL Catalog Number: WL-LP-X-2-40-X/LEDR40-UNV Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Notes: Type: H INDY16-44005 Wet-Lock Series BOE)JHI&óDJFODZ-&%BOE'MVPSFTDFOU8SBQ-VNJOBJSFT *13BUFE8FU-PDBUJPOT Project: ________________________________ Specifications: Approved By: ___________________________ Housing: Double channel housing of Electrical: Standard ballast - Electronic less than 20-gauge CRS, type 304 stainless steel or aluminum construction. 10% THD high performance instant start (0°F) universal voltage (120-277 volt). See options for other choices. End Caps: Precision stamped 20-gauge type Fixture Type: ___________________________ Cat. Number: ___________________________ Standard 304 stainless steel end caps secured to housing with standard stainless steel fasteners or optional hub assembly. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Gasket: Closed cell extruded SealPro™ NSF Listed gasketing. Resists grease and solvents. Installation: Four .312” debossed holes for Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: (Standard) Smooth surface .125" White/ Opal high impact blend virgin acrylic. Linear clear prismatic polycarbonate optional (LPx ) Sources: T5, T5HO, T8 and LED (For total LED lumens generated in a fixture multiply array lumens by the number of arrays. Example 4400 x 2 arrays = 8800 lumens. Fluorescent lamps supplied by others.) 25 Year Optional NSF Warranty WET LOCATION C-2 NON-FOOD ZONE HOSE DOWN IP 55 surface mounting. One .875” (1/2” trade-size) flattened and silicone sealed knockout located on back of housing for wiring. See below for other mounting and supply entry options. Rows: Joiner bands provided for continuous row mounting (See Option: CRM). Please specify number of fixtures in each run. 85 PSI IEC 60529 RATED Listings: UL and CUL Listed for Wet Location. Rated IP-55 dust and water resistance. NSF Listed for Food, Splash and Non-Food zones. Optionally rated 85 psi hosedown (HD85). 3.7" 5.5" 4.50" 6" WL-A WL-B WL-LPC WL-D 9.00" 8" 2.6" 4.00" Ordering Information: Example: WL-LPD-3-40-4/T8-UNV-FF WL - - 4FSJFT-FOT1SPöMF WL - - - .BUFSJBM4J[F4PVSDF A = 1-2 Lamps/1 LEDs B = 2 Lamps/LEDs C = 2 Lamps/LEDs Ω D = 3-4 Lamps/2 LEDs 1 = CRS Ext. & Int. 2 = SS Ext. & CRS Int. 3 = SS Ext. & Int. 4 = AL Ext. & CRS Int. 7PMUBHF 120V 277V 347V UNV (Blank)= Opal Arcylic LP= Clear Prismatic (Linear) Fluorescent LED Arrays 20 = 2' Housing 1 or 2/T8 = F17T8 (G13) 1 or 2/LEDR35 = 2200 Lumen Array(s) 1 or 2/T5 = F14WT5 (G5) 1 or 2/LEDR40 = 2200 Lumen Array(s) 1 or 2/T5HO = F24WT5 (G5) 40 = 4' Housing 1 or 2/T8 = F32T8 (G13) 1 or 2/T5 = F28WT5 (G5) 1/T5HO = F54WT5 (G5) 80 = 8' Housing 2, 4, 6 or 8/T8 = F32T8 (Tandem) 2, 4, 6, or 8/T5HO = F54WT5HO (Tandem) 1 or 2/LEDR35 = 4400◊ Lumen Array(s) 1 or 2/LEDR40 = 4400◊ Lumen Array(s) 0QUJPOT FF = Fuse & Holder FD = Double Fuse & Holders 2/EB = Two Ballasts, (Two Circuits) EBL = -20°F Electronic Ballast EBPRS= Program Rapid Start Ballast EBDIM= Electronic Dimming Ballast HLO= High Light Output Ballast* 1/EM = 1 Lamp Battery Pack (700L) 2/EM = 1 or 2 Lamp Battery Pack (1400L)* CRM = Custom Row Mounting* TP = Stainless Steel Tamperproof Fasteners SSH = Stainless Hubs (2) for Feed Thru Supply HD85 = 85 P.S.I. Hosedown* WHT= White Finished Stainless Steel PMB= Pendant Mount Brackets (2) CMB= Corner Mount Brackets (2) AMB= Adjustable Mount Bracket (2) * Note: Consult factory for multiple options marked "*". ‡ Housings made of CRS or Aluminum are capable of NSF Non-Food Zone with GG option. Ω Not available in 8 foot size. ◊ For total lumens generated in a fixture multiply array lumens by the number of arrays. Example 4400 x 2 arrays = 8800 lumens. ©2013 Kurtzon Lighting Catalog Number: LC6LED-277-6LCLED-6-40K-8B24 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: K Notes: INDY16-44005 6" LED Cylinder DATE:TYPE: LCC6LED FIRM NAME: PROJECT: 120 - 277V 0-10V Dimming 1000-1800 Lumens APPLICATIONS: LiteForms™ LCC6LED Series is a 6”commercial grade LED cylinder with available outputs between 1000-1800 lumens. This is suitable to replace most indoor/outdoor CFL cylinder applications in a variety of commercial, retail, and institutional spaces to achieve wide distribution illumination patterns on vertical walls or columns while realizing substantial energy and maintenance savings. Rated for a minimum of 50,000 hrs life (70% lumen maintenance) with ambient temperatures up to 30ºC (86ºF) during operation. HOUSING: Seamless .058" thick extruded aluminum cylinder body with durable powder coat paint finish and die cast aluminum canopy arm (wall mount) in a variety of architectural colors including Prescolite's exclusive Zet, metallic silver. REFLECTOR: High purity spun aluminum self-flanged reflector with iridescence suppressed Alzak semi-diffuse anodized (standard) or optional white or black painted finish. LED LIGHT ENGINE: The LCC6LED light engines use either 36, 48, or 60 mid power Nichia LEDs, specifically mixed to provide a minimum of 80 CRI with 3 SCDM color consistency. The use of multiple mid power LEDs allows for optimal thermal management by effectively spreading the heat over a larger area, eliminating hot spots on the LEDs. A diffuse yet highly transmissive lens obscures the view of the LEDs and creates a smooth, even look from below. For conversion to millimeters, multiply inches by 25.4 Not to Scale The light engine is available in multiple lumen packages and Kelvin temperatures to accommodate any design requirement. The system is designed to provide optimal life and lumen maintenance (50,000 hrs at 70% lumen maintenance). The reflector/light engine assembly features a twist-and-lock installation and is mechanically retained with a safety cable for ease of maintenance O 4-1/2" 1-1/4" LED DRIVER: The LCC6LED is offered standard with a 25-watt constant current Osram LED driver with 0-10V flicker free dimming to 10%. Other driver options are available including Osram LED 0-10V dimming to 1% (DM1), Lutron EcoSystem to 1% (EDM), or Lutron 2-wire Leading Edge dimming to 1% (120V only). All options are Class 2 compliant, have inherent short-circuit and overload protection, and meet UL 8750 with a 50,000 hour minimum anticipated life. 13-1/2" 12-1/4" INSTALLATION: Available cylinder mounting options include wall mount, ceiling/surface mount, pendant stem mount, and cord mount. Each mounting has a quick connect feature that allows easy access for future technology upgrades. CERTIFICATIONS: CSA certified to US and Canadian safety standards. Wall mount suitable for wet location. Surface and Pendant suitable for wet location under canopy/covered ceilings only. Cord mount suitable for damp locations. O 6" SURFACE WARRANTY: 5 Year Warranty. See www.prescolite.com for details. Pendant, wall, and cord mount line art on page 3. CATALOG NUMBER: CYLINDER ❑LCC6LED 6" LED Cylinder MOUNTING EXAMPLE: LCC6LEDP18L35K8WFL45 WH OUTPUT LED COLOR TEMP CRI VOLTAGE OPTIONS BEAM ❑10L ❑27K ❑8 ❑Blank ❑Blank ❑WFL45 ❑P 1000 2700 80+ 120-277 Standard 0-10V 45 Pendant (18" Volt CRI Delivered dimming to Kelvin Degree standard) ❑120V Lumens ❑30K 10% Cutoff ❑S 120V ❑14L 3000 ❑EDM3 Surface (for 1 400 1,2 Kelvin Lutron ❑CM 2DM) Delivered ❑35K EcoSystem to Cord Mount Lumens 3500 1% ❑W ❑18L Kelvin ❑2DM Wall Mount 1800 ❑40K Lutron 2 Wire Delivered 4000 Leading Edge Kelvin Lumens Dimming to 1% ❑50K (120V only) 5000 ❑DM1 Kelvin Osram dimming to 1% 0-10V REFLECTOR FINISH REFLECTOR COLOR ❑BC ❑Blank Painted Black Clear Alzak, Cone Semi-Diffuse ❑WC Painted White Cone CYLINDER COLOR ❑BA Brushed Aluminum ❑BZ Bronze ❑BL Matte Black ❑WH Matte White ❑Z Zet NOTES: 1 Cord length 6 feet, clear sleeve 2 Plastic bushings are grey on white, brushed aluminum and zet cylinder; black on black and bronze 3 Consult factory for 3-wire dimming option A Division of Hubbell Lighting, Inc. In a continuing effort to offer the best product possible we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Web: www.prescolite.com • Tech Support: (888) 777-4832 LFO-LED-016 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: K Notes: INDY16-44005 PHOTOMETRIC DATA LCC6LEDx10L LCC6LEDx14L LCC6LEDx18L Input Voltage 120-277V 120-277V 120-277V Input Frequency 50/60 Hz 50/60 Hz 50/60 Hz Input Current 0.130 (120v) 0.166 (120v). 0.207 (120v) 0.056 (277v) 0.071 (277v) 0.09 (277v) 19.7W 24.9W 700mA 700mA ® Input Power 15.5W 701 Millennium Blvd Greenville, SC 29607 Constant Current Output 700mA www.hubbelllighting.com NVLAP LAB CODE: 201003-0 Power Factor ≥0.90 ≥0.90 ≥0.90 THD <25% <20% <20% EMI Filtering FCC 47CFR FCC 47CFR FCC 47CFR Driver options ZONE 75˚ 400 400 %FIXT 53.3 83.0 99.7 100.0 0.0 100.0 NVLAP LAB CODE: 201003-0 60˚ /15 TTS = 24.9 SCOLITE 2 Lm/W CC6LEDS14L30K8WFL45WH ECT D - 6" LED Cylinder ING CRITERION = 1.1 7DT-V1 TER: 5.000 3000K LEDs OT25WPRG1250C/UNV/DIM/J IN CANDELA/SQ METER DRIVER LIC- Part #93044138 um with Clear Alzak t #93057761 IS ABSOLUTE FOR THE IDED. LUMENS 800 800 PAGE: 3 OF 8 45˚ 1200 1200 0˚ 15˚ 30˚ DEG CANDELA 0 5 15 25 35 45 55 65 75 85 90 1145 1136 1088 1121 858 328 21 9 0 0 0 86 254 413 393 189 26 2 1 0 100.0 LCC6LEDS14L30K8WFL45WH LED Light Engine: 3000K, 80+ CRI System Wattage: 19.7W Fixture Delivered Lumens: 1364 Fixture Efficacy: 69.2 Spacing Criteria: 1.1 300 300 60˚ 600 600 45˚ 1.1 900 900 0˚ 15˚ CANDELA 0 5 15 25 35 45 55 65 75 85 90 881 890 894 907 641 247 10 2 1 0 0 80% 0 0 Zonal Cavity Method 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 50 30 10 70 30 10 50 30 97 88 96 90 95 88 94 86 3 100 93 79 84 81 78 94 85 87 83 79 74 50 98 30 91 92 10 50 30 10 50 86 84 82 78 74 89 82 84 77 81 73 86 80 83 76 72 78 74 10 71 5 88 79 72 67 87 78 72 67 76 71 66 74 70 66 73 69 65 6 83 73 66 61 81 72 66 61 70 65 61 69 64 60 68 63 60 78 67 61 56 77 67 60 56 65 60 55 64 59 55 63 58 55 8 73 63 56 51 72 62 56 51 61 55 51 60 55 51 59 54 50 9 10 69 65 58 54 52 48 47 44 68 64 58 54 51 48 47 43 57 53 51 47 47 43 56 52 51 47 47 43 55 51 50 47 47 LCC6LEDS18L35K8WFL45WH LUMENS 0-60 1361 99.8 0-90 1364 100.0 0 0.0 1364 100.0 43 Test No. 15.00459 LUMINANCE DATA IN CANDELA/ SQ. METER Angle in Vertical Average - 0º 45° 19142 55° 955 %LUMINAIRE 65° 259 75° 85° 212 0 Zonal Cavity Method COEFFICIENTS OF UTILIZATION % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 30 10 50 30 1 2 113 110 107 105 110 108 105 103 104 102 100 100 98 107 101 97 93 104 99 95 92 96 93 90 93 90 97 88 96 90 95 88 94 86 3 100 93 80 84 81 79 4 70 50 30 10 70 94 86 88 80 83 75 98 92 50 92 85 30 87 79 10 50 30 10 50 83 75 89 83 85 78 81 74 87 80 83 76 73 79 75 10 72 5 89 79 73 68 87 78 72 68 77 71 67 75 70 66 73 69 66 6 83 73 67 62 82 73 66 62 71 65 61 70 65 61 68 64 60 7 79 68 61 57 77 67 61 56 66 60 56 65 60 56 64 59 56 8 74 63 57 52 73 63 56 52 62 56 52 60 55 51 59 55 51 9 10 70 65 59 55 52 49 48 44 69 65 58 55 52 48 48 44 57 54 52 48 48 44 57 53 51 48 47 44 56 52 51 47 47 LCC6LEDS14L30K8WFL45WH 30˚ Test No. 15.00306 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 D INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. 1681 75° 85° % Effective Ceiling Cavity Reflectance CANDELA DISTRIBUTION DEG 65° 113 110 107 105 110 108 105 103 104 102 100 100 98 106 101 96 93 104 99 95 92 96 93 90 93 90 7 90-180 1.14 1.03 1.00 1.00 0.91 1 2 4 ZONE 75˚ CANDELA/SQ METER 0.0 100.0 ZONAL LUMEN SUMMARY 90˚ = 19.7 m/W 0 1747 COEFFICIENTS OF UTILIZATION 0-180 %FIXT 55.2 84.0 99.8 100.0 0.0 100.0 CRITERION = 6.000 99.7 1747 Test No. 15.00459 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 ISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. RY S 3 7 1 4 0 4 1741 0-90 CANDELA DISTRIBUTION ® 701 Millennium Blvd Greenville, SC 29607 %LUMINAIRE 0-60 90-180 90˚ LUMENS Kelvin Kelvin Kelvin Kelvin Kelvin LUMINANCE DATA IN CANDELA/ SQ. METER Angle in Vertical Average - 0º 45° 36604 55° 2889 ZONAL LUMEN SUMMARY 0-180 www.hubbelllighting.com MMARY MENS 931 1450 1741 1747 0 .00306 1747 0-10V Room Cavity Ratio 108 310 514 519 251 40 6 0 0 5000 4000 3500 3000 2700 -30ºC to +30ºC LED Light Engine: 3500K, 80+ CRI System Wattage: 24.9W Fixture Delivered Lumens: 1747 Fixture Efficacy: 70.2 Spacing Criteria: 1.1 LUMENS Lumen Multiplier Table Unless specified, photometrics for the LCC6LED are published below at a nominal 3000 or 3500 Kelvin temperature. This table may be used to approximate the lumen values at different Kelvin temperatures. Power consumption would stay the same. Part 15, Class A Room Cavity Ratio A LiteForms - 6" LCC6LED Cylinder DRIVER DATA Part8 15, Class A Part 15, Class A 15.00459 PAGE: 3 OF /20/15 Operating Temperature -30ºC to +30ºC-30ºC to +30ºC PRESCOLITE : LCC6LEDS18L35K8WFL45WH Dimming (standard) 0-10V 0-10V LED Cylinder cular Aluminum - Part #93057761 Over-voltage, over-current, short-circuit protected 757DT-V1 -Nichia Lumen output & input wattage may vary slightly with EDM/2DM/DM1 O.: OT25W/PRG/1250C/UNV/DIM/J am Drivers ant WN IS ABSOLUTE FOR THE VIDED. LCC6LEDS18L35K8WFL45WH : Catalog Number: LC6LED-277-6LCLED-6-40K-8B24 Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFO-LED-014 • 4/29/15 44 Test No. 15.00306 ® 701 Millennium Blvd Greenville, SC 29607 Catalog Number: LC6LED-277-6LCLED-6-40K-8B24 Submitted by ESL-Spectrum www.hubbelllighting.com NVLAP LAB CODE: 201003-0 Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) 305 Type: K Notes: INDY16-44005 PAGE: 3 OF 7 LITE LEDS10L30K8WFL45WH Cylinder -V1 0K LEDs 25W/PRG/1250C/UNV/DIM/J IVER PHOTOMETRIC DATA LiteForms - 6" LCC6LED Cylinder with Clear Alzak Finish- Part #93057761 - Part #93044138 ABSOLUTE FOR THE SAMPLE PROVIDED. LUMENS 63 181 327 306 137 21 3 1 0 TS = 15.5 Lm/W CT NG CRITERION = ER: 6.000" ZONE 1034 99.5 1039 100.0 250 250 60˚ 500 500 45˚ 1.1 750 750 0˚ 15˚ 0 0.0 1039 100.0 CANDELA DISTRIBUTION 75˚ IN CANDELA/SQ METER %LUMINAIRE 0-90 90-180 90˚ LUMENS 0-60 0-180 %FIXT 54.9 84.4 99.5 100.0 0.0 100.0 LUMINANCE DATA IN CANDELA/ SQ. METER Angle in Vertical Average - 0º 45° 14182 55° 955 ZONAL LUMEN SUMMARY 30˚ DEG CANDELA 0 5 15 25 35 45 55 65 75 85 90 668 663 628 720 504 183 10 3 1 0 0 389 75° 85° 212 0 % Effective Ceiling Cavity Reflectance 80% 70% 50% 30% 10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 30 10 50 30 1 2 113 110 107 105 110 108 105 103 104 102 100 100 98 107 101 97 93 104 99 95 92 96 93 90 93 90 97 88 96 90 95 88 94 86 3 100 93 80 84 81 78 4 70 50 30 10 70 94 86 87 79 83 75 98 92 50 92 85 30 86 79 10 50 30 10 50 82 74 89 85 82 77 81 73 86 80 83 76 73 78 75 10 72 5 89 79 73 68 87 78 72 67 76 71 67 75 70 66 73 69 66 6 83 73 66 62 82 72 66 61 71 65 61 69 64 60 68 63 60 7 Test No. 15.00305 Tested at 25ºC Ambient in accordance to IESNA LM-79-2008 65° Zonal Cavity Method COEFFICIENTS OF UTILIZATION Room Cavity Ratio MARY ENS 570 877 034 039 0 039 LCC6LEDS10L30K8WFL45WH LED Light Engine: 3000K, 80+ CRI System Wattage: 15.5W Fixture Delivered Lumens: 1039 Fixture Efficacy: 67.0 Spacing Criteria: 1.1 78 68 61 56 77 67 61 56 66 60 56 64 59 55 63 59 55 8 74 63 56 52 72 62 56 51 61 55 51 60 55 51 59 54 51 9 10 69 66 59 55 52 48 48 44 68 65 58 54 52 48 47 44 57 53 51 47 47 44 56 53 51 47 47 44 55 52 50 47 47 LCC6LEDS10L30K8WFL45WH 43 Test No. 15.00305 Dimming Compatibility Table HED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. Dimming Ballast DM/DM1 DM/DM1 EDM 2DM Manufacturer Lutron DVTV Leviton AWRMG-7xx, AWSMG-7xx, AWSMT-7xx Lutron Lutron Web Link http://bit.ly/11jSvZg http://bit.ly/1BJn2R9 http://bit.ly/1vtjHAl http://bit.ly/1nF4Zp1 O 5-1/4" 5" 2-7/8" 1/4 " See notes 1&2 17-5/8" 72" on page 1 4-1/2" 84-1/4" ADJUSTABLE TO CUSTOMER REQUIREMENTS 29-7/8" 12-1/4" 12-1/4" 12-1/4" O 6" 8-7/8" 6" O 6" WALL MOUNT PENDANT MOUNT Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Boulevard • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2015 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • LFO-LED-014 • 4/29/15 CORD MOUNT Catalog Number: LJT14-40HLG-FAA12-EDU Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: M Notes: INDY16-44005 LJT14 1' × 4', LED Troffer PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION Luminaire housing and end caps are die-formed code-gauge cold-rolled steel. Optical system hinges from either side for easy access to LED module and electrical components. FEATURES • Full distribution LED troffer • Direct replacement of fluorescent 1x4 • Long-life, 60,000 hour LEDs at L80 reduce life cycle maintenance costs • Four LED color choices and 80 CRI • Many shielding choices • Two door frame choices • Metal to metal light leak protection on all four sides of shielding frame • Fixed output, step dimming (high/low/off), or 0-10V dimming drivers available • Hinged optical system allows easy access to LED modules and electrical from below the ceiling • All models standard with IC rating • DesignLights Consortium® (DLC) qualified • Five year warranty FINISH All metal parts processed with a multi-stage phosphate bonding treatment and finished with a high reflectance baked white enamel. SHIELDING Lens is high transmission pattern #12 acrylic (A12) for light diffusion without compromise to light output. Other shielding may be specified. If desired shielding media is not shown in ordering guide, contact your local Hubbell Lighting representative. INSTALLATION An access plate is furnished with each recessed fixture for fast wiring connections without the necessity to open the fixture or wireway. ORDERING INFORMATION LJT 14 MODEL – LW ML HL VL Low Watt Medium Lumen High Lumen Very High Lumen SIZE LUMEN OUTPUT 14 1' × 4' See Product Availability Table Below PRODUCT AVAILABILITY SIZE OUTPUT NOMINAL LUMENS 14 LW 2,485-2,605 ML 3,605-3,860 HL 4,430-4,755 VL 4,920-5,350 SHIELDING G Grid1 SM Surface Mount CM Cable Mount2 3000K 3500K 4000K 5000K WATTS 26 39 51 55 A12 Pattern 12 Acrylic Lens A12125 Pattern 12 Acrylic Lens, 0.125" Nominal DOOR A12F Pattern 12 Frosted FS White Flush Acrylic Lens Steel FA White Flush A12125F Pattern 12 Frosted Aluminum Acrylic Lens, 0.125" Nominal A19 Pattern 19 Acrylic Lens, 0.156" Nominal A19F Pattern 19 Frosted Acrylic Lens 0.156" BEST EFFICACY 97-102 92-98 88-94 91-97 Lumens will vary according to color temperatures and other factors. See specific photometric test(s). WARRANTY Five year warranty. (Terms and Conditions Apply) U – CEILING TYPE 30 35 40 50 CERTIFICATION All luminaires are built to UL 1598 and 2108 standards, and bear appropriate CSA labels. Damp location labeling is standard. Emergency equipped fixtures labeled UL924. Adheres to LM79, LM80 and TM21 industry standards. IC rating is standard on all models. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. EXAMPLE LJT14-35MLG-FSA12-EU – COLOR TEMP LJT LED Lensed Troffer CEILING COMPATIBILITY Designed for recessed installation in standard inverted tee grid ceilings (G). Four integral T-bar clips standard. Also available for recessed installation in hard ceilings (G with FK accessory), surface mount at ceiling plane (SM), or cable mount suspension below ceiling plane (CM). For compatibility with specific ceilings contact your Hubbell Lighting representative. DRIVER VOLTAGE E Fixed Output ESD Step Dimming ED 0-10V Dimming U 120V-277V For hard ceilings use flange kit accessory. 2 Order hanger accessories separately. 3 For compatibility with Dual-Lite LiteGear® inverters in lieu of installed battery pack, contact Hubbell Lighting Representative. 4 Not available with Surface Mount. Damp label—standard. IC rating—standard. 1 Page 1/3 Rev. 11/06/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com – OPTIONS 3-Wire Flex 4-Wire Flex 5-Wire Flex Emergency Battery Pack Installed, 1400 Lumens3,4 GLR Fast Blow Fuse G1 Single Gasketing (Door to Housing) G2 Double Gasketing (G1 and Lens to Door) G3 Triple Gasketing (G2 and Housing to Ceiling) CP Chicago Plenum GTD Not Available C388 C488 C588 ELL14 ACCESSORIES (ORDER SEPARATELY) FK14 1' × 4' Single Flange Kit CM48Y1SC3F-KIT 48" Cable Mount Kit for 1' wide Cable Mount Fixtures, 3-Wire LED / LJT14 Catalog Number: LJT14-40HLG-FAA12-EDU Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: M Notes: INDY16-44005 LJT14 1' × 4', LED Troffer PHOTOMETRIC DATA LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet Test 15.00231 Test Date 02/06/2015 ENERGY DATA LJT14-40LW-XXA12-EDU LJT LED, Lensed Troffer 1 x 4 led with A12 pattern acrylic prismed lens D700C30UNVTZC 1.00 LED 2606 25.50 Recessed 0º = 90 90º = 90 0º = 1.23 90º = 1.13 Length: 3.81 Width: 0.83 Height: 0.00 INDOOR CANDELA PLOT Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 102 YES-VDT NORMAL USE $2.40 based on 3000 hrs. and $0.08 per KWH 90 75 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens %Lamp 978 1523 2272 2606 2606 37.5 58.4 87.2 100.0 100.0 650 %Fixt. 37.5 58.4 87.2 100.0 100.0 60 1300 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 Test 15.00191 Test Date 02/02/2015 ENERGY DATA LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet LJT14-40ML-XXA12-EDU LJT LED, Lensed Troffer 1 x 4 led with A12 pattern acrylic prismed lens D10C55UNVTC 1.00 LED 3860 39.40 Recessed 0º = 90 90º = 90 0º = 1.23 90º = 1.13 Length: 3.81 Width: 0.83 Height: 0.00 INDOOR CANDELA PLOT Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 98 Noncompliant 90 $2.42 based on 3000 hrs. and $0.08 per KWH 75 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens %Lamp 1445 2253 3365 3860 3860 37.4 58.4 87.2 100.0 100.0 950 %Fixt. 37.4 58.4 87.2 100.0 100.0 60 1900 0 15 0.0 30 Horiz 0-180 45.0 45 90.0 Test 15.00192 Test Date 05/14/2014 LUMINAIRE DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet ENERGY DATA LJT14-40HL-XXA12-EDU LJT LED, Lensed Troffer x 4 led with A12 pattern acrylic prismed lens D15C55UNVTC 1.00 LED 4755 50.50 Recessed 0º = 90 90º = 90 0º = 1.23 90º = 1.13 Length: 3.81 Width: 0.83 Height: 0.00 INDOOR CANDELA PLOT Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 94 Noncompliant 90 $2.53 based on 3000 hrs. and $0.08 per KWH 75 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens %Lamp 1780 2775 4145 4755 4755 37.4 58.4 87.2 100.0 100.0 1200 %Fixt. 37.4 58.4 87.2 100.0 100.0 60 2400 0 15 0.0 Page 2/3 Rev. 11/06/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com 30 Horiz 0-180 45.0 45 90.0 LED / LJT14 Catalog Number: LJT14-40HLG-FAA12-EDU Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: M Notes: INDY16-44005 LJT14 1' × 4', LED Troffer DIMENSIONAL DATA CEILING COMPATIBILITY FK14 Flange Kit Type G End View 413⁄16" End 1/2" 225⁄8" 225⁄8" 15" 13/16" 15" 1/4" Ø 33⁄4" 33⁄4" 481⁄16" Side View 471⁄16" 481⁄16" End Side For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. 12" Top View Side 47⁄16" 1" 7⁄8 KOS, 2 PLCS For hard ceiling applications, order FK14 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. For flanged fixtures in FKCR row configurations, the FKCR adapter bracket kit is required in addition to the FK14 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK14 & (1) FKCR) Row cut out dimensions using FK14s & FKCR adapters: Width 123/8", Length [48" × (# in row)] + 3/8". Example: (48" × 2) + 3/8" = 963/8" Flange kit rough in dimensions for single unit only: 123/8" × 483/8" 35⁄8" 11⁄2" 3/8" A: 7/8" Diameter knockout K: 2" × 3" through hole for access plate. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. DIMENSIONAL DATA - SURFACE MOUNT (SM) AND CABLE MOUNT (CM) 43" 27⁄8" 7/8" Feed KO 27⁄8" A A 51⁄4" A A NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. 91⁄2" 127⁄8" 485⁄16" 53⁄16" Side View End View SURFACE MOUNT CABLE MOUNT Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 1⁄4" to 1⁄2" provided as shown, marked "A". Order CM ceiling type. Access plate supplied for cable mounting or suspension. Use CM48Y1 C3F-KIT 48" cable mount kit. Includes 3 wire feed cord. For other wiring needs, contact Hubbell Lighting representative. Mounting knock-outs, 1⁄4" to 1⁄2", provided as shown, marked "A". Page 3/3 Rev. 11/06/15 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com LED / LJT14 Catalog Number: NRG-406-2 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: N Notes: INDY16-44005 ceiling mount Cat. # Approvals Job Type nrg®400 series lumasquare® I Outdoor Lighting applications • Efficient lighting distribution and good uniformity for commercial and industrial applications, such as interior lighting for offices, lobbies, stairwells, corridors, parking garages, and storage areas. Aesthetic appearance and durable construction permit outdoor and indoor security lighting for walkways, apartments, schools, hotels, motels, and commercial building Specifications • Unique prismatic polycarbonate refractor for low brightness and even distribution. • One-piece, injection molded, bronze polycarbonate housing. Permanent color with textured finish. Very low profile - 5 inch height. Concealed latching. Ideal for indoor and outdoor damp applications. Two point mounting for stability • Reflector for HPS is hydroformed aluminum with Anodal® finish for maximum reflectivity. (Reflector reduces glare by shielding the arc tube from normal viewing angles.) Fluorescent reflector is aluminum with white high reflectance finish. IES Type V distribution • HPS has Class H normal power factory reactor ballast. -40°F starting, 60 Hz, 120 volt only. Fluorescent: (2) 120V, 13W reactor ballasts (lamps instant start down to 32°F). (2) 120V, 28W reactor ballasts (lamps start down to -20°F). Lamp included. HPS is B-17 clear medium base. Fluorescent is (2) 13W twin tube, or (2) 28W 15mm Quad tube, single ended listings • Listed to UL1598 for damp locations indoor and outdoor A B A B 10” square 254 mm square 5” 127 mm ordering information Catalog Number1 Ballast Type Min. Start Temp Input Amps Weight lbs. (kg) -40F 1.8 6 (2.7) Wattage Voltage 50 120 NRG-406-21 2 x 13 120 Preheat 32F .7 5 (2.3) NRG-4561 2 x 28 120 NPF Reactor -20F 1.2 6 (2.7) High Pressure Sodium NRG-4011 1 Note: Reactor Fluorescent CSA certified for outdoor applications only; UL indoor/ outdoor, NRG-406 uses GX23 base, NRG-456 uses GX32d-3 base lamps Lamp included Accessories - Order Separately Catalog Number S-319-B S-314-B S-319-B S-319-B S-329-B Description 4” Cast aluminum round junction box for surface conduit mounting with two mounting lugs, four 1/2” tapped hubs, and three plugs; leaves fixture 2” from ceiling Replacement Part Catalog Number 264-0225-9904 Description Replacement refractor with molded hinges photometric reports Catalog Number nrg-401 GLN-1-G nrg-406-2 nrg-456 Report # NM-BC hp02075.ies 1414 hp03243.ies hp05001.ies Due to our continued efforts to improve our products, product specifications are subject to change without notice. Hubbell Outdoor Lighting • 701 Millennium Boulevard • Greenville, SC 29607 • phone: 864-678-1000 For more information visit our web site: www.hubbelloutdoor.com Outdoor Lighting Copyright © 2011 HUBBELL lighting All Rights Reserved nrg400-spec8/11 Printed in USA Catalog Number: Type: HBLHO-72LU-A2-5K-W-092-CDX Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Notes: P INDY16-44005 CAT.# APPROVALS JOB TYPE SPECIFICATIONS Applications The NEW Hubbell LED Highbay is designed to efficiently light any large interior space such as heavy industrial settings, warehouses, gyms, churches, swimming pools/natatorium and shopping malls. Well sealed design works well for food processing applications. Construction • High performance LED design delivering up to 100 lumens per watt • LED count 72 • LED driven at 920 mA • Minimum operating temperature of -40˚C • Fixture weight: 29 lbs. Shipped weight: 33 lbs. • UL Sanitation listed for food processing A B DIMENSIONS C A B C A Optics/Electrical System • Custom engineered LED optics providing optimally controlled and evenly distributed light • Three distinct distributions: aisle, narrow and wide • Sealed optic for long life and durability A HBLHO A LED Light Engine • High output LEDs • 100,000 hours, long life at L70 • 2700-5000°K Color Temperature - See ordering logic for more information • 68 CRI on 5000˚K and 80 CRI on 27K, 3K, 35K and 4K options B AB C 18”11” 6” D Thermal Performance # of LEDs HBLHO 72 40˚C C A B C D Listings - LED Driver • Circuit Loading Information • 1.50 amps @ 120v 60 Hz • 0.75 amps @ 240v 60 Hz • 0.65 amps @ 277v 60 Hz • Power factor greater than 0.90 • Standard 0 to 10v dimmable drivers • FCC 47CFR Part 15 Class B Compliant • CSA tested to UL1598 Wet Location, IP56 Warranty • Five years from date of purchase ORDERING INFORMATION ORDERING EXAMPLE: HBLHO-72LU-A2-5K-N-070-ND-WH HBLHO Series 092 # of LEDs Voltage Mount Hub SERIES HBLHO High Output Highbay HBL Series NUMBER OF LEDS 72L 72 High Performance LEDs 120 - 277V 1120V 2208V 3240V 4277V Note: Voltage must be specified for Fusing and Occupancy Sensor compatibility. MOUNT APendant CCone S Straight stanchion XCeiling YYoke Distribution HUB DRIVE CURRENT 2¾” 092 Drive Current 920 MA Available with A, C, X and Y Mount VOLTAGE U Color Temp 31” Available with A, C, X Mount 4 5 1 ¼” 1 ½” Available with S Mount COLOR TEMPERATURE 27K 3K 2700˚ Kelvin - 80 CRI 3000˚ Kelvin - 80 CRI 35K 4K 5K 3500˚ Kelvin - 80 CRI 4000˚ Kelvin - 80 CRI 5000˚ Kelvin - 68 CRI Note: See Color Temperature De-Rating factors table on pg.2 DISTRIBUTION NNarrow WWide AAisle DIMMING CD ND Continous Dimming Non Dimming Dimming Colors ACCESSORIES COLORS BLBlack GRGrey WHWhite Options Notes:1.OCS unavailable with SL, ENCA or ENCG. OCS and WIH options can not be specified together 2.WIH only available with 120V or 277V 3.-F(X) Fixture fuse. Replace X with voltage: 1-120V, 2-208V, 3-240V, 4-277V 4. Wire Guard and SL Lens cannot be used together. (order as separate part #) HOOK/LOOP BLA-C4HLPX Fixture Mounting Hook Cord and Plug Set LG2S DUAL-LITE 250 VA LiteGear Emergency Lighting Inverter OPTIONS F(x) Fusing (replace “x” with voltage) ENCA Frosted Acrylic Protective Lens ENCG Glass Protective Lens OCS360 360˚ Lens Occupancy Sensor OCSA WG WIH Aisle Lens Occupancy Sensor Bottom Wire Guard4 Wireless Control System SL Sag Lens, Translucent White FP UL Sanitation, Food Processing HIL0082 HBLHO Spec Catalog Number: Type: HBLHO-72LU-A2-5K-W-092-CDX Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Notes: P INDY16-44005 pg 2 MOUNTING OPTIONS PENDANT MOUNT CONE MOUNT STANCHION (0˚) MOUNT CEILING MOUNT 347V/480V MOUNTING - Consult factory for availability. COLOR TEMPERATURE DE-RATING FACTORS NUMBER OF LEDS 347v/480v to 277v Step-Down Power Hook 17.5” 72 Narrow Aisle Wide 5000K 21010 19149 20208 4000K 17439 15894 16773 3500K 17229 15703 16570 3000K 16598 15128 15964 2700K 15968 14553 15358 277v HBL Fixture ORDERING INFORMATION MOUNTING ACCESSORIES OPTIONS FOR HBL/HO LED HIGHBAY SERIES (order separately) Plugs are twist-lock® type as manufactured by hubbell wiring devices. Factory installed ­– order with fixture by adding suffix. CORD, HOOK/LOOP -C4HL 4’ Cord, Hook/Loop -C6HL 6’ Cord, Hook/Loop -C8HL 8’ Cord, Hook/Loop -C10HL 10’ Cord, Hook/Loop -C12HL 12’ Cord, Hook/Loop x= 120V 4’ Cord, Hook/Loop and 120V 20A Twist-Lock® Plug BLA-C4HLP-4 4’ Cord, Hook/Loop and 277V 20A Twist-Lock® Plug BLA-C4HLP1-15A 4’ Cord, Hook/Loop and 120V 15A Twist-Lock® Plug BLA-C4HLP4-15A HOOK/LOOP1 4’ Cord, Hook/Loop and 277V 15A Twist-Lock® Plug converts to Loop with strap included Hook - cast aluminum 3/4” NPS male; includes safety screw; H34AL341 Swivel Aligner - complete with box for thru wiring; all hubs 1 CORD, HOOK/LOOP & 20A PLUG Length BLA-C4HLP-1 tapped for 3/4” conduit - 25° swivel Cord, Hook/Loop and Plug must be added to fixture as option, example: -c2hlp4. NOTE: Cord used with above accessories is 16/3 SOWA 105°C NEMA configurations. 208V 240V 277V -C4HLP (X) 4’ 1 2 3 4 -C6HLP (X) 6’ 1 2 3 4 -C8HLP (X) 8’ 1 2 3 4 -C10HLP (X) 10’ 1 2 3 4 -C12HLP (X) 12’ 1 2 3 4 CORD, HOOK/LOOP & 15A PLUG 208V 240V 277V -C4HLP(X)-15a Length 4’ x= 120V 1 2 3 4 -C6HLP(X)-15a 6’ 1 2 3 4 -C8HLP(X)-15a 8’ 1 2 3 4 -C10HLP(X)-15a 10’ 1 2 3 4 -C12HLP(X)-15a 12’ 1 2 3 4 NOTE: 1. Plugs are twist-lock® type as manufactured by hubbell wiring devices 2. Pendant or Cone Mount Only - A and C Mount Only with 2 Hubb (3/4”) WI-HUBB WIH Wireless control system WARNING: Improper selection, installation, operation, servicing, removal, and disposal of lighting products may create serious hazardous including fires, explosions, shock, burns, cuts, impaired vision, falling objects, and environmental contamination. Reduce risks by using luminaire retainers/safety cables of equipment, the guidance of licensed professionals throughout the product life cycle, and following individual product, component, and accessory safety instructions and labels. We offer this in the interest of safety for our customers, who may not be aware of the potentially high risk involved in the misuse of these products. Due to our continued efforts to improve our products, specifications are subject to change without notice. Copyright © 2014 Hubbell Lighting All Rights Reserved. For more information visit our web site: http://www.hubbellindustrial.com/ Phone: 1-864-678-1000 HIL0082 HBLHO Spec - B 3/15 Catalog Number: Type: HBLHO-72LU-A2-5K-W-092-CDX-OCS360 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Notes: P1 INDY16-44005 CAT.# APPROVALS JOB TYPE SPECIFICATIONS Applications The NEW Hubbell LED Highbay is designed to efficiently light any large interior space such as heavy industrial settings, warehouses, gyms, churches, swimming pools/natatorium and shopping malls. Well sealed design works well for food processing applications. Construction • High performance LED design delivering up to 100 lumens per watt • LED count 72 • LED driven at 920 mA • Minimum operating temperature of -40˚C • Fixture weight: 29 lbs. Shipped weight: 33 lbs. • UL Sanitation listed for food processing A B DIMENSIONS C A B C A Optics/Electrical System • Custom engineered LED optics providing optimally controlled and evenly distributed light • Three distinct distributions: aisle, narrow and wide • Sealed optic for long life and durability A HBLHO A LED Light Engine • High output LEDs • 100,000 hours, long life at L70 • 2700-5000°K Color Temperature - See ordering logic for more information • 68 CRI on 5000˚K and 80 CRI on 27K, 3K, 35K and 4K options B AB C 18”11” 6” D Thermal Performance # of LEDs HBLHO 72 40˚C C A B C D Listings - LED Driver • Circuit Loading Information • 1.50 amps @ 120v 60 Hz • 0.75 amps @ 240v 60 Hz • 0.65 amps @ 277v 60 Hz • Power factor greater than 0.90 • Standard 0 to 10v dimmable drivers • FCC 47CFR Part 15 Class B Compliant • CSA tested to UL1598 Wet Location, IP56 Warranty • Five years from date of purchase ORDERING INFORMATION ORDERING EXAMPLE: HBLHO-72LU-A2-5K-N-070-ND-WH HBLHO Series 092 # of LEDs Voltage Mount Hub SERIES HBLHO High Output Highbay HBL Series NUMBER OF LEDS 72L 72 High Performance LEDs 120 - 277V 1120V 2208V 3240V 4277V Note: Voltage must be specified for Fusing and Occupancy Sensor compatibility. MOUNT APendant CCone S Straight stanchion XCeiling YYoke Distribution HUB DRIVE CURRENT 2¾” 092 Drive Current 920 MA Available with A, C, X and Y Mount VOLTAGE U Color Temp 31” Available with A, C, X Mount 4 5 1 ¼” 1 ½” Available with S Mount COLOR TEMPERATURE 27K 3K 2700˚ Kelvin - 80 CRI 3000˚ Kelvin - 80 CRI 35K 4K 5K 3500˚ Kelvin - 80 CRI 4000˚ Kelvin - 80 CRI 5000˚ Kelvin - 68 CRI Note: See Color Temperature De-Rating factors table on pg.2 DISTRIBUTION NNarrow WWide AAisle DIMMING CD ND Continous Dimming Non Dimming Dimming Colors ACCESSORIES COLORS BLBlack GRGrey WHWhite Options Notes:1.OCS unavailable with SL, ENCA or ENCG. OCS and WIH options can not be specified together 2.WIH only available with 120V or 277V 3.-F(X) Fixture fuse. Replace X with voltage: 1-120V, 2-208V, 3-240V, 4-277V 4. Wire Guard and SL Lens cannot be used together. (order as separate part #) HOOK/LOOP BLA-C4HLPX Fixture Mounting Hook Cord and Plug Set LG2S DUAL-LITE 250 VA LiteGear Emergency Lighting Inverter OPTIONS F(x) Fusing (replace “x” with voltage) ENCA Frosted Acrylic Protective Lens ENCG Glass Protective Lens OCS360 360˚ Lens Occupancy Sensor OCSA WG WIH Aisle Lens Occupancy Sensor Bottom Wire Guard4 Wireless Control System SL Sag Lens, Translucent White FP UL Sanitation, Food Processing HIL0082 HBLHO Spec Catalog Number: Type: HBLHO-72LU-A2-5K-W-092-CDX-OCS360 Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Notes: P1 INDY16-44005 pg 2 MOUNTING OPTIONS PENDANT MOUNT CONE MOUNT STANCHION (0˚) MOUNT CEILING MOUNT 347V/480V MOUNTING - Consult factory for availability. COLOR TEMPERATURE DE-RATING FACTORS NUMBER OF LEDS 347v/480v to 277v Step-Down Power Hook 17.5” 72 Narrow Aisle Wide 5000K 21010 19149 20208 4000K 17439 15894 16773 3500K 17229 15703 16570 3000K 16598 15128 15964 2700K 15968 14553 15358 277v HBL Fixture ORDERING INFORMATION MOUNTING ACCESSORIES OPTIONS FOR HBL/HO LED HIGHBAY SERIES (order separately) Plugs are twist-lock® type as manufactured by hubbell wiring devices. Factory installed ­– order with fixture by adding suffix. CORD, HOOK/LOOP -C4HL 4’ Cord, Hook/Loop -C6HL 6’ Cord, Hook/Loop -C8HL 8’ Cord, Hook/Loop -C10HL 10’ Cord, Hook/Loop -C12HL 12’ Cord, Hook/Loop x= 120V 4’ Cord, Hook/Loop and 120V 20A Twist-Lock® Plug BLA-C4HLP-4 4’ Cord, Hook/Loop and 277V 20A Twist-Lock® Plug BLA-C4HLP1-15A 4’ Cord, Hook/Loop and 120V 15A Twist-Lock® Plug BLA-C4HLP4-15A HOOK/LOOP1 4’ Cord, Hook/Loop and 277V 15A Twist-Lock® Plug converts to Loop with strap included Hook - cast aluminum 3/4” NPS male; includes safety screw; H34AL341 Swivel Aligner - complete with box for thru wiring; all hubs 1 CORD, HOOK/LOOP & 20A PLUG Length BLA-C4HLP-1 tapped for 3/4” conduit - 25° swivel Cord, Hook/Loop and Plug must be added to fixture as option, example: -c2hlp4. NOTE: Cord used with above accessories is 16/3 SOWA 105°C NEMA configurations. 208V 240V 277V -C4HLP (X) 4’ 1 2 3 4 -C6HLP (X) 6’ 1 2 3 4 -C8HLP (X) 8’ 1 2 3 4 -C10HLP (X) 10’ 1 2 3 4 -C12HLP (X) 12’ 1 2 3 4 CORD, HOOK/LOOP & 15A PLUG 208V 240V 277V -C4HLP(X)-15a Length 4’ x= 120V 1 2 3 4 -C6HLP(X)-15a 6’ 1 2 3 4 -C8HLP(X)-15a 8’ 1 2 3 4 -C10HLP(X)-15a 10’ 1 2 3 4 -C12HLP(X)-15a 12’ 1 2 3 4 NOTE: 1. Plugs are twist-lock® type as manufactured by hubbell wiring devices 2. Pendant or Cone Mount Only - A and C Mount Only with 2 Hubb (3/4”) WI-HUBB WIH Wireless control system WARNING: Improper selection, installation, operation, servicing, removal, and disposal of lighting products may create serious hazardous including fires, explosions, shock, burns, cuts, impaired vision, falling objects, and environmental contamination. Reduce risks by using luminaire retainers/safety cables of equipment, the guidance of licensed professionals throughout the product life cycle, and following individual product, component, and accessory safety instructions and labels. We offer this in the interest of safety for our customers, who may not be aware of the potentially high risk involved in the misuse of these products. Due to our continued efforts to improve our products, specifications are subject to change without notice. Copyright © 2014 Hubbell Lighting All Rights Reserved. For more information visit our web site: http://www.hubbellindustrial.com/ Phone: 1-864-678-1000 HIL0082 HBLHO Spec - B 3/15 Catalog Number: TRV/X-24NB/27-5K-T3-UNVDBT Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: S1 Notes: INDY16-44005 Type: rev. 09.21.2015 Project Name: TRAVERSE (LED) Traverse Wall Pack Max Weight: 24.0 lbs Notes: design . performance . technology www.beaconproducts.com Sample TRV-D Ordering 60NB-136 / A 5K / B T5R UNV / C / D DETAILS GENIXX / E PEC / F G A. MODEL 12 1/2” BBT / H F. CONTROL OPTIONS TRV-D Traverse down light TRV-U Traverse up light (lens req.) 1 GENI-XX Energeni 7 G. ELECTRICAL OPTIONS 7 1/4” Side View B. ENGINE-WATTS PEC photocell, button 24NB-27 27 Watts - LED array 2PF dual power feed 2,3 24NB-55 55 Watts - LED array MOB motion sensor 33% or 50% 36NB-80 80 Watts - LED array 48NB-110 110 Watts - LED array OCS occupancy sensor (on/off) 60NB-136 136 Watts - LED array BPC cold weather battery pack 4 dimming 5,6 14” C. CCT - COLOR TEMP H. COLOR 3K 3000K BBT basic black textured 4K 4000K BMT black matte textured 5K 5000K (std.) WHT white textured Front View D. OPTICS Top View metallic bronze textured BZT bronze textured T2 type II DBT dark bronze textured T3 type III GYS gray smooth T4 type IV DPS dark platinum smooth T5R type V, rectangular GNT green textured 2X2 narrow spot flood MST metallic silver textured 5X5 medium flood MTT metallic titanium textured E. VOLTAGE Bottom View MBT UNV 120-277V 347 347V 480 480V OWI old world iron RAL ______________ MOB ORDERING INFORMATION: When ordering a fixture with the motion detection option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. 33% or 50% - _____ ?? / MT 1 to 30 min. - __________ TRV-D / 48E-63 / AMB / T5SW / 180 / UNV / MOB - __________ High to Dim Delay 1 Low Level Mounting Height (ft.) indoor use only 2 not available on 240NB-27 3 not available @ 347V or 480V input 4 36NB-80 only 5 not available on 48NB-110 6 not available on 60NB-136 When ordering Energeni, specify the routine setting code (example GENI-04). See Energeni brochure and instructions for setting table and options. Not available with sensor options. 7 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 Fax: (941) 751-5535 ORDERING Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: TRV/X-24NB/27-5K-T3-UNVDBT Type: S1 Notes: INDY16-44005 rev. 09.21.2015 TRAVERSE (LED) Traverse Wall Pack Max Weight: 24.0 lbs design . performance . technology General: The Beacon TRV luminaire is a wall surface mounted luminaire with a field replaceable LED light engine & optical bezel system. Internal components are totally enclosed in rain-tight and corrosion-resistant die cast aluminum housing. The TRV Luminaire is suitable for wet locations. Housing/LED Thermal Management: The Beacon TRV luminaire consists of a die cast aluminum two-piece housing. The die cast main (thermal) housing provides direct heat exchange between the LED light engine and the cool outdoor air by drawing heat through integral heat channels and out to the sculptured and functional luminaire surface. LED drivers are thermally isolated from the main housing, mechanically attached and heat sinked to the rear housing The main housing is designed with heat dissipating fins for LED thermal management without the use of metallic screens, cages, or fans. The shape of the main housing is designed to prevent debris accumulation and as a bird nesting deterrent. The back and main housings are designed to hinge open for easy mounting and easy access. Mounting & Installation: The rear housing (back plate) is designed with various bolt patterns for direct wall mounting or mounting to a recessed 4” junction box. The rear housing has three integral 3/4” NPT power feed locations (bottom and each side) for surface mounted conduit applications. After mounting the rear housing to the wall or junction box, the main housing is designed to hang and hinge closed after connecting the male and female quick connectors. The mounting design permits a simple retrofit to existing wall luminaires that utilize surface mount or recessed junction boxes. Bezel Optical System: Each Traverse luminaire is supplied with an Optical one piece cartridge system consisting of an LED engine, LED lamps, optics, gasket and stainless steel bezel. The cartridge is held together with internal brass standoffs soldered to the board so that it can be field replaced as a one piece Optical system. A two-piece die cut silicone and polycarbonate foam gasket ensures a weather-proof seal around each individual LED and allows the Traverse luminaire to be rated for high-pressure hose down applications. The optical cartridge is secured to the extruded housing with fasteners and a heat pad to ensure thermal conductivity. The optics are held in place without the use of adhesives and the complete assembly is gasketed for high pressure hose down cleaning. The cartridge assembly is available in various lighting distributions using TIR designed Acrylic optical lenses over each LED. Printed Circuit Board (PCB): Aluminum thermal clad board with 0.062” thick aluminum base layer “high temperature” HT-06503 or equivalent (subject to change) dielectric (0.003” thick, thermal conductivity of 2.2 W/MK, UL RTI of 140°C) 0.0014” thick copper circuit layer Circuit layer designed with copper pours to minimize thermal impedance across dielectric. Board shall be supplied with QPAD-3 fiberglass reinforced thermal pad 0.005” thick thermal conductivity of 2.0 W/Mk. Continuous use temperature of 180°C UL94 V-0. Board will be mounted to the heat sink using 12 #4-40 screws to ensure contact with thermal pad and heat sink. Use of thermal grease will not be allowed. LifeShield™ Circuit: (optional) Thermal circuit shall protect the luminaire from excessive temperature by interfacing with its 0-10V dimmable drivers to reduce drive current as necessary. The factory-preset temperature limits shall be designed to ensure maximum hours of operation to assure L70 rated lumen maintenance. The device shall activate at a specific, factory-preset temperature, and progressively reduce power over a finite temperature range in recognition of the effect of reduced current on the internal temperature and longevity of the LEDs and other components. A luminaire equipped with the device may be reliably operated in any ambient temperature up to 55ºC (131ºF). The LifeShield™ thermal regulation circuit will allow higher maximum Wattages than would be permissible on an unregulated luminaire (if some variation in light output is permissible), without risk of premature LED failure. Operation shall be smooth and undetectable to the eye. Thermal circuit shall directly measure the temperature at the LED solder point. LifeShield™ shall consist of surface mounted components mounted on the LED engine (printed circuit board). For maximum simplicity and reliability, the device shall have no dedicated enclosure, circuit board, wiring harness, gaskets, or hardware. Device shall have no moving parts, and shall operate entirely at low voltage (NEC Class 2). The device shall be located in an area of the luminaire that is protected from the elements. LifeShield™ shall be designed to “fail on”, allowing the luminaire to revert to full power in the event of an interruption of its power supply, or faulty wiring connection to the drivers. Device shall be able to co-exist with other 0-10V control devices (occupancy sensors, external dimmers, etc.). The device will effectively control the solder point temperature as needed; otherwise it will allow the other control device(s) to function unimpeded. Motion Activated Luminaires: Beacon TRV luminaires are available with an optional passive infrared (PIR) motion sensor capable of detecting motion within 24 feet of the sensor, 360° around the luminaire, when placed at an 8 foot mounting height. When no motion is detected for 5 minutes, the Motion Response system reduces the Wattage from 10% to 50% (factory set at 50% reduction) of the maximum Wattage, reducing the light level accordingly. When motion is detected by the PIR sensor, the luminaire returns to full Wattage and full 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 light output. Please contact Beacon Products if project requirements vary from standard configuration. Electrical: Luminaires are equipped with an LED driver that accepts 100V through 277V, 50 Hz to 60 Hz (UNIV), or a driver that accepts 347V or 480V input. Power factor is .92 at full load. All electrical components are rated at 50,000 hours at full load and 40°C ambient conditions per MIL-217F Notice 2. Optional 0 to 10 volt dimming drivers are available upon request. Component-to-component wiring within the luminaire may carry no more than 80% of rated load and is listed by UL for use at 600VAC at 50°C or higher. Plug disconnects are listed by UL for use at 600 VAC, 15A or higher. 15A rating applies to primary (AC) side only. Surge Protector: The on-board surge protector shall be a UL recognized component for the United States and Canada and have a surge current rating of 20,000 Amps using the industry standard 8/20 pSec wave. The LSP shall have a clamping voltage of 825V and surge rating of 540J. The case shall be a high-temperature, flame resistant plastic enclosure. Cold Weather Battery Pack: The emergency driver shall be capable of operating an LED load of up to 23.1 Watts at rated current (700 mA) for a minimum of 90 minutes. It is suitable for damp locations as well as sealed and gasketed fixtures. The BPC shall have 37 Watts of input power and a 54.0 Watts-hour battery capacity and shall comply with emergency standards set forth by the current NEC. Fasteners: All fasteners shall be stainless steel. When tamper resistant fasteners are required, spanner HD (snake eye) style shall be provided (special tool required, consult factory). Power Supply/Driver Requirements: U.L. UL1310, Class 2 and UL48 compliant Color Rendering Index (CRI): Luminaire shall have a minimum CRI of 67 at 5000K. Operating Environment: Shall be able to operate normally in ambient temperatures from -40°C to 40°C. Finish: Finish shall be a Beacote V polyester powder-coat electro-statically applied and thermocured. Beacote V finish shall consist of a five stage iron phosphate chemical pretreatment regimen with a polymer primer sealer, oven dry off, and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for corrosion resistance and resists cracking or loss of adhesion per ASTM D522 and resists surface impacts of up to 160 inch-pound. Agency Certification: The luminaire shall bear a CSA label and be marked suitable for wet locations. Warranty: Beacon luminaires feature a 5 year limited warranty. Beacon LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED drivers are covered by a 5 year limited warranty. PIR sensors carry a 5 year limited warranty from the sensor manufacturer. See Warranty Information on www.beaconproducts.com complete details and exclusions. Power/Lumens & Distribution Engine Wattage Delivered TM21 Calculated % Lumen Delivered Lumens Maint. LPW at 100,000 hrs (varies by optic) 24NB 27 2752-3014 105-115 96.19% 24NB 55 5138-5500 93-100 96.19% 36NB 80 6935-8215 93-103 94.87% 48NB 110 10240-10950 93-103 92.73% 60NB 136 12800-13700 93-103 85.79% TM21 is the framework for taking LM-80 data and making useful LED lifetime projections. Reported and Calculated Lifetimes shown are based on hours at the time of this printing. For current Reported and Calculated hours please contact factory or Beacon’s web-site. CCT (COLOR TEMP) Lumen Output Multipliers CRI (Color Rendering) 5000K = 1.0 min 67 CRI 4000K = .92 min 70 CRI 3000K = .75 min 80 CRI Due to our continued efforts to improve our products, product specifications are subject to change without notice. Fax: (941) 751-5535 SPECIFICATION Catalog Number: Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: A670TSRLED991/480WB/ 4ARC45T3/MDL03/SRR1HSS/BKT W1 Notes: INDY16-44005 A670TSR LED YALE SERIES LumInAIRE DESIGn • the luminaire shall be a stylized victorian acorn fixture provided with a decorative cast aluminum fitter, a polycarbonate or acrylic clear textured acorn and a cast aluminum cage and roof. • the luminaire shall be appointed with a cast aluminum decorative 4-vane finial. • the luminaire shall have LeD light sources and roof mounted, down-lighting optics. • the luminaire shall be 18” diameter and 38 5 / 8” over-all height. • the luminaire shall be e.t.L. or U.L. listed in U.S. and canada. FITTER - STAnDARD • the fitter shall be heavy wall cast aluminum, 356 alloy for high tensile strength. • it shall have an 8 1 / 2” inside diameter opening to attach to the 8” neck of the acorn globe. • When ordered with a Sternberg aluminum pole, the fitter shall be welded to the pole top or tenon for safety and to ensure the fixture will be plumb, secure and level over the life of the installation. • the fitter shall have a one- piece ring bug gasket to resist insect penetration into lamp assembly. LED Lighting Caged Acorns SpecificationS Cast Aluminum Finial A670TSRLED 508P Cast Aluminum Roof LED Roof Mounted Optics Cast Aluminum Cage Polycarbonate or Acrylic Textured Lens Cast Aluminum 508 Fitter Cast Aluminum Finial A670TSRLED 990 Cast Aluminum Roof LED Roof Mounted Optics Cast Aluminum Cage 990 FITTER SERIES OPTIOn • the fitter shall be heavy wall cast aluminum, 360 die cast alloy for high tensile strength. • it shall have a 9 1/ 4” inside diameter opening to attach to the 8” neck of the acorn globe. • it shall have a hinged, tool-less entry door that provides open EPA = 1.40 (ft 2) WEIGHT = 48 LBS access to all of the components. • the 990 shall have an optional terminal block for ease of wiring, an Rated IP65 optional twist-Lock photocell receptacle, an optional Gfci outlet for auxiliary power needs. • the top mounted ballast mounting plate shall be cast aluminum and provide tool-less removal from the housing using 2 finger latches. • When ordered with a Sternberg aluminum pole, the fitter shall be set screwed to the pole top or tenon. • the fitter shall have a one- piece ring bug gasket to resist insect penetration into lamp assembly. • When supplied with Gfi receptical a hole will be provided for cord and plug installation with the access door closed. • When cord and plug is not in use a filler plug will be provided and shall be tethered to the fitter for easy recovery and installation. LIST NO. A670TSR LED YALE SERIES DRIvER • the LeD driver shall be securely mounted inside the fitter, for optimized performance and longevity. Polycarbonate or Acrylic Textured Lens Cast Aluminum 990 Fitter 1-14 (Continued on next page) Catalog Number: Submitted by ESL-Spectrum Job Name: Type: A670TSRLED991/480WB/ 4ARC45T3/MDL03/SRR1HSS/BKT IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) W1 Notes: INDY16-44005 LED Lighting Caged Acorns A670TSR LED YALE SERIES LIST NO. A670TSR LED YALE SERIES SpecificationS LIGHT SOuRCES • the luminaire shall use high output, high brightness LeDs. • the LeDs shall be mounted in arrays, on printed circuit boards designed to maximize heat transfer to the heat sink surface. • the LeDs shall be attached to the printed circuit board with not less than 90% pure silver to insure optimal electrical and thermal conductivity. • the LeDs and printed circuit boards shall be protected from moisture and corrosion by a conformal coating of 1 to 3 mils. • the LeDs and printed circuit board construction shall be environmentally friendly and 100% recyclable. they shall not contain lead, mercury or any other hazardous substances and shall be RoHS compliant. • the LeD life rating shall be determined in accordance with LM-80. LIGHT SOuRCE 6ARC62T-MDL05 T2 SPEC LumEnS 9975 T3 SPEC LumEnS 10270 T3R SPEC LumEnS 10185 T5 SPEC LumEnS 10515 WATTS 145 6ARC35T-MDL05 8755 9015 8940 9230 145 6ARC45T-MDL05 6ARC62T-MDL03 6ARC45T-MDL03 6ARC35T-MDL03 9330 7445 6960 6530 9605 7580 7090 6655 9525 7670 7170 6730 9835 7730 7230 6785 4ARC62T-MDL03 5130 5050 5080 5340 4ARC35T-MDL03 4505 4435 4460 4690 4ARC45T-MDL03 3ARC62T-MDL03 3ARC45T-MDL03 3ARC35T-MDL03 2ARC62T-MDL03 2ARC45T-MDL03 2ARC35T-MDL03 4800 3935 3680 3455 2645 2475 2320 4725 3705 3465 3250 2675 2505 2350 4750 3990 3735 3505 2685 2510 2355 4995 4040 3780 3550 2755 2580 2420 145 96 96 96 67 67 67 53 53 53 34 34 34 OPTICS • the luminaire shall be provided with individual, acrylic, refractor type optics applied to each LeD. • the luminaire shall provide type ___ (2, 3, 3R or 5) light distribution per the ieSna classifications. testing shall be done in accordance with LM-79. PERFORmAnCE • the LeDs and LeD driver shall operate over a -40°c (-40°f) to +50°c (122°f) ambient air temperature range. • the High performance white LeDs will have a life expectancy of approximately 70,000 hours with not less than 70% of original brightness (lumen maintenance), rated at 25°c. • the High Brightness, High output LeD’s shall be 4500K (3500K or 6200K option) color temperature with a typical of 70 cRi. • the Luminaire shall have a minimum ______ (see table) initial delivered lumen rating when operated at steady state with an average ambient temperature of 25°c (77°f). 555 Lawrence Ave. Roselle, IL 60172 • 847- 588 - 3400 • Fax 847- 588 - 3440 www.sternberglighting.com Email: info @ sternberglighting.com 1-14 Catalog Number: Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: A670TSRLED991/480WB/ 4ARC45T3/MDL03/SRR1HSS/BKT W1 Notes: INDY16-44005 A670TSR LED YALE SERIES LIST NO. A670TSR LED YALE SERIES LED Lighting Caged Acorns SpecificationS ELECTROnIC DRIvERS • the driver shall be U.L. Listed. • the driver shall have overload as well as short circuit protection. • the driver shall be a Dc voltage output, constant current design, 50 /60HZ. • the driver accepts input voltage from 120-277 (MDL). optional 347-480 (MDH). • the driver shall have a minimum power factor of 0.90. • the driver shall be rated at full load with tHD<20%. • the driver is dimmable using 0-10V signal. • the luminaire shall be supplied with line-ground, line-neutral and neutral-ground electrical surge protection in accordance with ieee/anSi c62.41.2 guidelines. • the LeD driver shall be supplied with a quick-disconnect electrical connector on the power supply, providing easy power connections and fixture installation. CAGED ACORn • the caged acorn shall be 18” diameter and 29 1/ 2” tall with an 8” diameter neck. • the caged acorn shall be made of _____________________ vandal resistant, clear textured polycarbonate or dent resistant (DR) clear textured acrylic. for acrylic, add “a” to model number. • the caged acorn shall be supplied with a cast aluminum finial and a solid, cast aluminum roof which includes optimized heat sinks to provide maximum life and performance for the LeD light sources. • the caged acorn shall be sealed to the cast aluminum roof to provide a moisture-free and bug-free optics chamber for the LeD light sources and Rated IP65. • the Luminaire shall have a distinctively styled, decorative cast aluminum cage. ARmS • the arms shall be cast aluminum and/or extruded aluminum. • arms with decorative filigree shall have meticulously detailed scroll work and gracefully curved brackets. • (All except BAPT and 779 arms) the arms shall be bolted to a post mount adaptor which is welded to the pole to ensure proper alignment. • (Twin TA and twin 579 arms) the arms shall be attached to a decorative center hub which will fit the center tenon of the pole (not shown). 555 Lawrence Ave. Roselle, IL 60172 • 847- 588 - 3400 • Fax 847- 588 - 3440 www.sternberglighting.com Email: info @ sternberglighting.com 1-14 Catalog Number: Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: A670TSRLED991/480WB/ 4ARC45T3/MDL03/SRR1HSS/BKT W1 Notes: INDY16-44005 A670TSR LED YALE SERIES LIST NO. A670TSR LED YALE SERIES LED Lighting Caged Acorns SpecificationS PHOTOCELL OPTIOnS Electronic Button Cell Option • photocells shall be electronic button type. • on single post-top fixtures, the photocell shall be mounted in the fitter and pre-wired to the driver. • on multiple head fixtures, photocells shall be mounted in the pole shaft, on an access plate. the photocell is not pre-wired since drivers are mounted in the fitters and packaged separately. • the photocell is instant-on at 1.5 foot-candles and turns off 5-10 seconds at 2-3 foot-candles. • the photocell is 120- 277 volt. Twist-Lock Type Option • photocells shall be twist-lock design, thermal-bimetallic switch type. • 990 Fitter: photocells shall be mounted in the fitter on the photocell bracket and pre-wired to the driver. on multi-fixture poles the photocell shall be mounted on top of pole/arm/hangstraight. the photocell is not pre-wired on multi-fixture poles since drivers are mounted in the fitters and packaged separately. • Twist-Lock Roof option (SRR and SRR1): on single-fixture poles, the photocell shall be mounted on top of roof, protected by a waterproof spinning and gasket; and pre-wired to the driver. • photocell time delay is 2 minutes to turn on at 1.5 foot-candles and 2 minutes to turn off at no more than 6 foot-candles. • the photocell is 120-277 volt.. FInISH • prior to coating, the luminaire shall be chemically cleaned and etched in a 5-stage washing system which includes alkaline cleaning, rinsing, phosphoric etching, reverse-osmosis water rinsing and non-chrome sealing to ensure corrosion resistance and excellent adhesion for the finish coat. • the finish coat shall be an electrostatically applied semi-gloss, super durable polyester powder coat, baked on at 400°f, to provide a durable, color retentive finish. • *the optional _________ (Verde Green or Swedish iron) finish shall be hand-brushed using a 3-step process. * (OPTION) WARRAnTy • the luminaire shall be free from all defects in materials and workmanship for a period of seven (7) years from the date of manufacture. • the luminaire manufacturer shall warrant the LeD boards/ system, during the stated warranty period, against failure defined as more than 10% simultaneous non-operating LeDs. • the driver shall be warranted for seven (7) years. 555 Lawrence Ave. Roselle, IL 60172 • 847- 588 - 3400 • Fax 847- 588 - 3440 www.sternberglighting.com Email: info @ sternberglighting.com 1-14 Catalog Number: Submitted by ESL-Spectrum Job Name: Type: A670TSRLED991/480WB/ 4ARC45T3/MDL03/SRR1HSS/BKT IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) W1 Notes: INDY16-44005 A670TSR LED YALE SERIES CAGED ACORnS 18” W 38 FITTERS acoRnS / fitteRS / aRMS pM - WB 18” W 18” W 5 / 8” 46 29 5/8” 101⁄8” W 101⁄8” H 101⁄8” W 101⁄8” H 101⁄8” W 101⁄4” H 101⁄8” W 113⁄4” H 101⁄8” W 113⁄4” H 101⁄8” W 113⁄4” H 101⁄2” W 153⁄4” H 101⁄2” W 131⁄8” H 101⁄2” W 131⁄8” H 101⁄2” W 153⁄4” H 5P (508) Fits 3” poles or tenons and arms below BD4 (508BD4) Fits 4” poles or tenons BD5 (508BD5) Fits 5” poles or tenons B7 (508B7) Fits 7” poles or tenons BD7 (508BD7) Fits 7” poles or tenons 7 (708) Fits 4” poles or tenons - 3” with adapter & large arms 990 Fits 3” poles or tenons and large arms 994 3” Tenon 991 Fits 3” poles or tenons and large arms 992 Fits 3” poles or tenons and large arms 993 Fits 3” poles or tenons and large arms 995 4” Tenon 11 1/ 2 ” 11 3 / 4” 80 18 ” 21 3/ 8 ” 16 480 18 3/ 8 ” 10 3” Only 34 ” 31 1/ 2” TA 478 779 27 1/ 2” 16 1/ 4 ” 450PB 579 16 1/ 2 ” 11 1/ 4 ” 15 1/ 4 ” 1 / 2” 18 ” 17 7/ 8” 12 3/ 4” 15 1/ 8 ” 1-14 39WB 19 5/ 8 ” TASCR 16 1/ 4 ” 19 7/ 8” 1/ 2 ” 17 ” 478TS 11 1/ 4” 17 3/ 4 ” See Arms Section for more information 16 1/ 4 ” 50 (80D Downswept Arm) 15 1/ 4” CDR- CL Custom Logo A670TSRLED Polycarbonate A670TASRLED Acrylic ARmS - POST mOunT (Pm) or WALL BRACKETS (WB) 10 1/ 8 ” 1 / 2” 15 1/ 4 ” 10 3/ 8 ” 6236 55 24” 55L 22 3 / 4” BAPT Twin Only 70 Catalog Number: Submitted by ESL-Spectrum Job Name: Type: A670TSRLED991/480WB/ 4ARC45T3/MDL03/SRR1HSS/BKT IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) W1 Notes: INDY16-44005 LED Caged Acorn Specifications BUiLDinG a paRt nUMBeR POST & ARm FIxTuRES ARM MOUNTED FIXTURE NO. OF ARMS 2 ACORN/FITTER/POSTARM CENTER POST TOP FIXTURE (PT) ACORN/FITTER A670SRLED/5P/579PT ACORN/FITTER/WALL BRACKET A670TSRLED/5P/50WB LED 4ARC PART numBER SELECTIOnS ACORnS • A670TSRLED 1 • A670TASRLED FITTERS • 5P • 7 • • • • • • • • • • 990 991 992 993 994 995 BD4 BD5 BD7 B7 DRIvER VOLTS 120-277 347-480 *6ARC only NOTES: 1 White POST ARmS • 50PM • 50DPM • 478PM • 478TSPM • 70PM* • 80PM • 80DPM • 480PM • 480DPM • 55PM • 55LPM • 6236PM • 579PT • TAPT • TASCRPT • BAPT PIER BASE • 450PB TYPE MDL MDH mA 03 05* polycarbonate acorns are available. Specify WP after acorn number. 2 Consult factory for specification details. 3 For 990 fitter only. LIGHT SOURCE COLOR 45 LIGHT SOURCE (See Post Section) 4212FP4 PT WALL FIxTuRES POST CAP POST TYPE T3 DRIVER DRIVER LED COLOR TYPE 6ARC 45 T5 OPTIONS MDL03 OPTIONS MDL03 FINISH BKT PIER FIxTuRES Uses same information boxes as wall fixture FINISH A670TSRLED/5P/450PB BKT ACORn / FITTER / PIER BASE WALL BRACKET ARmS • 50WB • 50DWB • 478WB • 478TSWB • 70WB* • 80WB • 80DWB • 480WB • 480DWB • 55WB • 55LWB • 6236WB • 579WB • TAWB • TASCRWB • 39WB* LIGHT SOuRCES* LED 6ARC 4ARC 3ARC 2ARC COLOR TEMP. (K) 62(00) 45(00) 35(00) *Consult factory for other color temperatures *No fitter required TYPE T2 T3 T3R T5 STAnDARD FInISHES* • BKT Black Textured • WHT White Textured • PGT Park Green Textured • ABZT Architectural Medium Bronze Textured • DBT Dark Bronze Textured *Smooth Finishes are available upon request CuSTOm FInISHES • OI Old Iron • RT Rust • WBR Weathered Brown • CD Cedar • WBK Weathered Black • TT Two Tone STERnBERG SELECT FInISHES • VG Verde Green • SI Swedish Iron • OWGT Old World Gray Textured OPTIOnS • PEC Photocell-Electronic 120-277 Volt • R 3 Receptacle Only for Twist-Lock Photo Cell • R13 Twist-Lock Photo Cell 120 - 277 Volt • SRR Solid Roof: Receptacle Only for Twist-Lock Photo Cell • SRR1 Solid Roof: Twist-Lock Photo Cell 120-277 Volt • FHD Dual Fuse & Holder - 208, 240, 480 Volt • PF per arm Pineapple Finial or Font (for TA, TASCR) • BF per arm Ball Finial or Font (for TA, TASCR) • CDR- CL2 Cast Decorative Ring with Custom Logo • G 3 GFI • HSS House Side Shield • TB Terminal Block 555 Lawrence Ave. Roselle, IL 60172 • 847- 588 - 3400 • Fax 847- 588 - 3440 www.sternberglighting.com Email: info @ sternberglighting.com 1-14 Catalog Number: TRV/X-48NB/110-5K-T3-UNVPEC-DBT Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: W2 Notes: INDY16-44005 Type: rev. 09.21.2015 Project Name: TRAVERSE (LED) Traverse Wall Pack Max Weight: 24.0 lbs Notes: design . performance . technology www.beaconproducts.com Sample TRV-D Ordering 60NB-136 / A 5K / B T5R UNV / C / D DETAILS GENIXX / E PEC / F G A. MODEL 12 1/2” BBT / H F. CONTROL OPTIONS TRV-D Traverse down light TRV-U Traverse up light (lens req.) 1 GENI-XX Energeni 7 G. ELECTRICAL OPTIONS 7 1/4” Side View B. ENGINE-WATTS PEC photocell, button 24NB-27 27 Watts - LED array 2PF dual power feed 2,3 24NB-55 55 Watts - LED array MOB motion sensor 33% or 50% 36NB-80 80 Watts - LED array 48NB-110 110 Watts - LED array OCS occupancy sensor (on/off) 60NB-136 136 Watts - LED array BPC cold weather battery pack 4 dimming 5,6 14” C. CCT - COLOR TEMP H. COLOR 3K 3000K BBT basic black textured 4K 4000K BMT black matte textured 5K 5000K (std.) WHT white textured Front View D. OPTICS Top View metallic bronze textured BZT bronze textured T2 type II DBT dark bronze textured T3 type III GYS gray smooth T4 type IV DPS dark platinum smooth T5R type V, rectangular GNT green textured 2X2 narrow spot flood MST metallic silver textured 5X5 medium flood MTT metallic titanium textured E. VOLTAGE Bottom View MBT UNV 120-277V 347 347V 480 480V OWI old world iron RAL ______________ MOB ORDERING INFORMATION: When ordering a fixture with the motion detection option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. 33% or 50% - _____ ?? / MT 1 to 30 min. - __________ TRV-D / 48E-63 / AMB / T5SW / 180 / UNV / MOB - __________ High to Dim Delay 1 Low Level Mounting Height (ft.) indoor use only 2 not available on 240NB-27 3 not available @ 347V or 480V input 4 36NB-80 only 5 not available on 48NB-110 6 not available on 60NB-136 When ordering Energeni, specify the routine setting code (example GENI-04). See Energeni brochure and instructions for setting table and options. Not available with sensor options. 7 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 Fax: (941) 751-5535 ORDERING Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: TRV/X-48NB/110-5K-T3-UNVPEC-DBT Type: W2 Notes: INDY16-44005 rev. 09.21.2015 TRAVERSE (LED) Traverse Wall Pack Max Weight: 24.0 lbs design . performance . technology General: The Beacon TRV luminaire is a wall surface mounted luminaire with a field replaceable LED light engine & optical bezel system. Internal components are totally enclosed in rain-tight and corrosion-resistant die cast aluminum housing. The TRV Luminaire is suitable for wet locations. Housing/LED Thermal Management: The Beacon TRV luminaire consists of a die cast aluminum two-piece housing. The die cast main (thermal) housing provides direct heat exchange between the LED light engine and the cool outdoor air by drawing heat through integral heat channels and out to the sculptured and functional luminaire surface. LED drivers are thermally isolated from the main housing, mechanically attached and heat sinked to the rear housing The main housing is designed with heat dissipating fins for LED thermal management without the use of metallic screens, cages, or fans. The shape of the main housing is designed to prevent debris accumulation and as a bird nesting deterrent. The back and main housings are designed to hinge open for easy mounting and easy access. Mounting & Installation: The rear housing (back plate) is designed with various bolt patterns for direct wall mounting or mounting to a recessed 4” junction box. The rear housing has three integral 3/4” NPT power feed locations (bottom and each side) for surface mounted conduit applications. After mounting the rear housing to the wall or junction box, the main housing is designed to hang and hinge closed after connecting the male and female quick connectors. The mounting design permits a simple retrofit to existing wall luminaires that utilize surface mount or recessed junction boxes. Bezel Optical System: Each Traverse luminaire is supplied with an Optical one piece cartridge system consisting of an LED engine, LED lamps, optics, gasket and stainless steel bezel. The cartridge is held together with internal brass standoffs soldered to the board so that it can be field replaced as a one piece Optical system. A two-piece die cut silicone and polycarbonate foam gasket ensures a weather-proof seal around each individual LED and allows the Traverse luminaire to be rated for high-pressure hose down applications. The optical cartridge is secured to the extruded housing with fasteners and a heat pad to ensure thermal conductivity. The optics are held in place without the use of adhesives and the complete assembly is gasketed for high pressure hose down cleaning. The cartridge assembly is available in various lighting distributions using TIR designed Acrylic optical lenses over each LED. Printed Circuit Board (PCB): Aluminum thermal clad board with 0.062” thick aluminum base layer “high temperature” HT-06503 or equivalent (subject to change) dielectric (0.003” thick, thermal conductivity of 2.2 W/MK, UL RTI of 140°C) 0.0014” thick copper circuit layer Circuit layer designed with copper pours to minimize thermal impedance across dielectric. Board shall be supplied with QPAD-3 fiberglass reinforced thermal pad 0.005” thick thermal conductivity of 2.0 W/Mk. Continuous use temperature of 180°C UL94 V-0. Board will be mounted to the heat sink using 12 #4-40 screws to ensure contact with thermal pad and heat sink. Use of thermal grease will not be allowed. LifeShield™ Circuit: (optional) Thermal circuit shall protect the luminaire from excessive temperature by interfacing with its 0-10V dimmable drivers to reduce drive current as necessary. The factory-preset temperature limits shall be designed to ensure maximum hours of operation to assure L70 rated lumen maintenance. The device shall activate at a specific, factory-preset temperature, and progressively reduce power over a finite temperature range in recognition of the effect of reduced current on the internal temperature and longevity of the LEDs and other components. A luminaire equipped with the device may be reliably operated in any ambient temperature up to 55ºC (131ºF). The LifeShield™ thermal regulation circuit will allow higher maximum Wattages than would be permissible on an unregulated luminaire (if some variation in light output is permissible), without risk of premature LED failure. Operation shall be smooth and undetectable to the eye. Thermal circuit shall directly measure the temperature at the LED solder point. LifeShield™ shall consist of surface mounted components mounted on the LED engine (printed circuit board). For maximum simplicity and reliability, the device shall have no dedicated enclosure, circuit board, wiring harness, gaskets, or hardware. Device shall have no moving parts, and shall operate entirely at low voltage (NEC Class 2). The device shall be located in an area of the luminaire that is protected from the elements. LifeShield™ shall be designed to “fail on”, allowing the luminaire to revert to full power in the event of an interruption of its power supply, or faulty wiring connection to the drivers. Device shall be able to co-exist with other 0-10V control devices (occupancy sensors, external dimmers, etc.). The device will effectively control the solder point temperature as needed; otherwise it will allow the other control device(s) to function unimpeded. Motion Activated Luminaires: Beacon TRV luminaires are available with an optional passive infrared (PIR) motion sensor capable of detecting motion within 24 feet of the sensor, 360° around the luminaire, when placed at an 8 foot mounting height. When no motion is detected for 5 minutes, the Motion Response system reduces the Wattage from 10% to 50% (factory set at 50% reduction) of the maximum Wattage, reducing the light level accordingly. When motion is detected by the PIR sensor, the luminaire returns to full Wattage and full 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 light output. Please contact Beacon Products if project requirements vary from standard configuration. Electrical: Luminaires are equipped with an LED driver that accepts 100V through 277V, 50 Hz to 60 Hz (UNIV), or a driver that accepts 347V or 480V input. Power factor is .92 at full load. All electrical components are rated at 50,000 hours at full load and 40°C ambient conditions per MIL-217F Notice 2. Optional 0 to 10 volt dimming drivers are available upon request. Component-to-component wiring within the luminaire may carry no more than 80% of rated load and is listed by UL for use at 600VAC at 50°C or higher. Plug disconnects are listed by UL for use at 600 VAC, 15A or higher. 15A rating applies to primary (AC) side only. Surge Protector: The on-board surge protector shall be a UL recognized component for the United States and Canada and have a surge current rating of 20,000 Amps using the industry standard 8/20 pSec wave. The LSP shall have a clamping voltage of 825V and surge rating of 540J. The case shall be a high-temperature, flame resistant plastic enclosure. Cold Weather Battery Pack: The emergency driver shall be capable of operating an LED load of up to 23.1 Watts at rated current (700 mA) for a minimum of 90 minutes. It is suitable for damp locations as well as sealed and gasketed fixtures. The BPC shall have 37 Watts of input power and a 54.0 Watts-hour battery capacity and shall comply with emergency standards set forth by the current NEC. Fasteners: All fasteners shall be stainless steel. When tamper resistant fasteners are required, spanner HD (snake eye) style shall be provided (special tool required, consult factory). Power Supply/Driver Requirements: U.L. UL1310, Class 2 and UL48 compliant Color Rendering Index (CRI): Luminaire shall have a minimum CRI of 67 at 5000K. Operating Environment: Shall be able to operate normally in ambient temperatures from -40°C to 40°C. Finish: Finish shall be a Beacote V polyester powder-coat electro-statically applied and thermocured. Beacote V finish shall consist of a five stage iron phosphate chemical pretreatment regimen with a polymer primer sealer, oven dry off, and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for corrosion resistance and resists cracking or loss of adhesion per ASTM D522 and resists surface impacts of up to 160 inch-pound. Agency Certification: The luminaire shall bear a CSA label and be marked suitable for wet locations. Warranty: Beacon luminaires feature a 5 year limited warranty. Beacon LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED drivers are covered by a 5 year limited warranty. PIR sensors carry a 5 year limited warranty from the sensor manufacturer. See Warranty Information on www.beaconproducts.com complete details and exclusions. Power/Lumens & Distribution Engine Wattage Delivered TM21 Calculated % Lumen Delivered Lumens Maint. LPW at 100,000 hrs (varies by optic) 24NB 27 2752-3014 105-115 96.19% 24NB 55 5138-5500 93-100 96.19% 36NB 80 6935-8215 93-103 94.87% 48NB 110 10240-10950 93-103 92.73% 60NB 136 12800-13700 93-103 85.79% TM21 is the framework for taking LM-80 data and making useful LED lifetime projections. Reported and Calculated Lifetimes shown are based on hours at the time of this printing. For current Reported and Calculated hours please contact factory or Beacon’s web-site. CCT (COLOR TEMP) Lumen Output Multipliers CRI (Color Rendering) 5000K = 1.0 min 67 CRI 4000K = .92 min 70 CRI 3000K = .75 min 80 CRI Due to our continued efforts to improve our products, product specifications are subject to change without notice. Fax: (941) 751-5535 SPECIFICATION Catalog Number: TRV/X-48NB/110-5K-T3-UNVDBT Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Type: W3 Notes: INDY16-44005 Type: rev. 09.21.2015 Project Name: TRAVERSE (LED) Traverse Wall Pack Max Weight: 24.0 lbs Notes: design . performance . technology www.beaconproducts.com Sample TRV-D Ordering 60NB-136 / A 5K / B T5R UNV / C / D DETAILS GENIXX / E PEC / F G A. MODEL 12 1/2” BBT / H F. CONTROL OPTIONS TRV-D Traverse down light TRV-U Traverse up light (lens req.) 1 GENI-XX Energeni 7 G. ELECTRICAL OPTIONS 7 1/4” Side View B. ENGINE-WATTS PEC photocell, button 24NB-27 27 Watts - LED array 2PF dual power feed 2,3 24NB-55 55 Watts - LED array MOB motion sensor 33% or 50% 36NB-80 80 Watts - LED array 48NB-110 110 Watts - LED array OCS occupancy sensor (on/off) 60NB-136 136 Watts - LED array BPC cold weather battery pack 4 dimming 5,6 14” C. CCT - COLOR TEMP H. COLOR 3K 3000K BBT basic black textured 4K 4000K BMT black matte textured 5K 5000K (std.) WHT white textured Front View D. OPTICS Top View metallic bronze textured BZT bronze textured T2 type II DBT dark bronze textured T3 type III GYS gray smooth T4 type IV DPS dark platinum smooth T5R type V, rectangular GNT green textured 2X2 narrow spot flood MST metallic silver textured 5X5 medium flood MTT metallic titanium textured E. VOLTAGE Bottom View MBT UNV 120-277V 347 347V 480 480V OWI old world iron RAL ______________ MOB ORDERING INFORMATION: When ordering a fixture with the motion detection option (MOB), please specify the appropriate information. These settings are specified in the ordering as shown in the example below. 33% or 50% - _____ ?? / MT 1 to 30 min. - __________ TRV-D / 48E-63 / AMB / T5SW / 180 / UNV / MOB - __________ High to Dim Delay 1 Low Level Mounting Height (ft.) indoor use only 2 not available on 240NB-27 3 not available @ 347V or 480V input 4 36NB-80 only 5 not available on 48NB-110 6 not available on 60NB-136 When ordering Energeni, specify the routine setting code (example GENI-04). See Energeni brochure and instructions for setting table and options. Not available with sensor options. 7 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 Fax: (941) 751-5535 ORDERING Submitted by ESL-Spectrum Job Name: IndyGo - Facility Upgrades Project Engineer: Parsons Brinckerhoff (Indianapolis) Catalog Number: TRV/X-48NB/110-5K-T3-UNVDBT Type: W3 Notes: INDY16-44005 rev. 09.21.2015 TRAVERSE (LED) Traverse Wall Pack Max Weight: 24.0 lbs design . performance . technology General: The Beacon TRV luminaire is a wall surface mounted luminaire with a field replaceable LED light engine & optical bezel system. Internal components are totally enclosed in rain-tight and corrosion-resistant die cast aluminum housing. The TRV Luminaire is suitable for wet locations. Housing/LED Thermal Management: The Beacon TRV luminaire consists of a die cast aluminum two-piece housing. The die cast main (thermal) housing provides direct heat exchange between the LED light engine and the cool outdoor air by drawing heat through integral heat channels and out to the sculptured and functional luminaire surface. LED drivers are thermally isolated from the main housing, mechanically attached and heat sinked to the rear housing The main housing is designed with heat dissipating fins for LED thermal management without the use of metallic screens, cages, or fans. The shape of the main housing is designed to prevent debris accumulation and as a bird nesting deterrent. The back and main housings are designed to hinge open for easy mounting and easy access. Mounting & Installation: The rear housing (back plate) is designed with various bolt patterns for direct wall mounting or mounting to a recessed 4” junction box. The rear housing has three integral 3/4” NPT power feed locations (bottom and each side) for surface mounted conduit applications. After mounting the rear housing to the wall or junction box, the main housing is designed to hang and hinge closed after connecting the male and female quick connectors. The mounting design permits a simple retrofit to existing wall luminaires that utilize surface mount or recessed junction boxes. Bezel Optical System: Each Traverse luminaire is supplied with an Optical one piece cartridge system consisting of an LED engine, LED lamps, optics, gasket and stainless steel bezel. The cartridge is held together with internal brass standoffs soldered to the board so that it can be field replaced as a one piece Optical system. A two-piece die cut silicone and polycarbonate foam gasket ensures a weather-proof seal around each individual LED and allows the Traverse luminaire to be rated for high-pressure hose down applications. The optical cartridge is secured to the extruded housing with fasteners and a heat pad to ensure thermal conductivity. The optics are held in place without the use of adhesives and the complete assembly is gasketed for high pressure hose down cleaning. The cartridge assembly is available in various lighting distributions using TIR designed Acrylic optical lenses over each LED. Printed Circuit Board (PCB): Aluminum thermal clad board with 0.062” thick aluminum base layer “high temperature” HT-06503 or equivalent (subject to change) dielectric (0.003” thick, thermal conductivity of 2.2 W/MK, UL RTI of 140°C) 0.0014” thick copper circuit layer Circuit layer designed with copper pours to minimize thermal impedance across dielectric. Board shall be supplied with QPAD-3 fiberglass reinforced thermal pad 0.005” thick thermal conductivity of 2.0 W/Mk. Continuous use temperature of 180°C UL94 V-0. Board will be mounted to the heat sink using 12 #4-40 screws to ensure contact with thermal pad and heat sink. Use of thermal grease will not be allowed. LifeShield™ Circuit: (optional) Thermal circuit shall protect the luminaire from excessive temperature by interfacing with its 0-10V dimmable drivers to reduce drive current as necessary. The factory-preset temperature limits shall be designed to ensure maximum hours of operation to assure L70 rated lumen maintenance. The device shall activate at a specific, factory-preset temperature, and progressively reduce power over a finite temperature range in recognition of the effect of reduced current on the internal temperature and longevity of the LEDs and other components. A luminaire equipped with the device may be reliably operated in any ambient temperature up to 55ºC (131ºF). The LifeShield™ thermal regulation circuit will allow higher maximum Wattages than would be permissible on an unregulated luminaire (if some variation in light output is permissible), without risk of premature LED failure. Operation shall be smooth and undetectable to the eye. Thermal circuit shall directly measure the temperature at the LED solder point. LifeShield™ shall consist of surface mounted components mounted on the LED engine (printed circuit board). For maximum simplicity and reliability, the device shall have no dedicated enclosure, circuit board, wiring harness, gaskets, or hardware. Device shall have no moving parts, and shall operate entirely at low voltage (NEC Class 2). The device shall be located in an area of the luminaire that is protected from the elements. LifeShield™ shall be designed to “fail on”, allowing the luminaire to revert to full power in the event of an interruption of its power supply, or faulty wiring connection to the drivers. Device shall be able to co-exist with other 0-10V control devices (occupancy sensors, external dimmers, etc.). The device will effectively control the solder point temperature as needed; otherwise it will allow the other control device(s) to function unimpeded. Motion Activated Luminaires: Beacon TRV luminaires are available with an optional passive infrared (PIR) motion sensor capable of detecting motion within 24 feet of the sensor, 360° around the luminaire, when placed at an 8 foot mounting height. When no motion is detected for 5 minutes, the Motion Response system reduces the Wattage from 10% to 50% (factory set at 50% reduction) of the maximum Wattage, reducing the light level accordingly. When motion is detected by the PIR sensor, the luminaire returns to full Wattage and full 2041 58th Avenue Circle East Bradenton, fl 34203 Phone: (800) 345-4928 light output. Please contact Beacon Products if project requirements vary from standard configuration. Electrical: Luminaires are equipped with an LED driver that accepts 100V through 277V, 50 Hz to 60 Hz (UNIV), or a driver that accepts 347V or 480V input. Power factor is .92 at full load. All electrical components are rated at 50,000 hours at full load and 40°C ambient conditions per MIL-217F Notice 2. Optional 0 to 10 volt dimming drivers are available upon request. Component-to-component wiring within the luminaire may carry no more than 80% of rated load and is listed by UL for use at 600VAC at 50°C or higher. Plug disconnects are listed by UL for use at 600 VAC, 15A or higher. 15A rating applies to primary (AC) side only. Surge Protector: The on-board surge protector shall be a UL recognized component for the United States and Canada and have a surge current rating of 20,000 Amps using the industry standard 8/20 pSec wave. The LSP shall have a clamping voltage of 825V and surge rating of 540J. The case shall be a high-temperature, flame resistant plastic enclosure. Cold Weather Battery Pack: The emergency driver shall be capable of operating an LED load of up to 23.1 Watts at rated current (700 mA) for a minimum of 90 minutes. It is suitable for damp locations as well as sealed and gasketed fixtures. The BPC shall have 37 Watts of input power and a 54.0 Watts-hour battery capacity and shall comply with emergency standards set forth by the current NEC. Fasteners: All fasteners shall be stainless steel. When tamper resistant fasteners are required, spanner HD (snake eye) style shall be provided (special tool required, consult factory). Power Supply/Driver Requirements: U.L. UL1310, Class 2 and UL48 compliant Color Rendering Index (CRI): Luminaire shall have a minimum CRI of 67 at 5000K. Operating Environment: Shall be able to operate normally in ambient temperatures from -40°C to 40°C. Finish: Finish shall be a Beacote V polyester powder-coat electro-statically applied and thermocured. Beacote V finish shall consist of a five stage iron phosphate chemical pretreatment regimen with a polymer primer sealer, oven dry off, and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 605.2 performance specification which includes passing a 3000 hour salt spray test for corrosion resistance and resists cracking or loss of adhesion per ASTM D522 and resists surface impacts of up to 160 inch-pound. Agency Certification: The luminaire shall bear a CSA label and be marked suitable for wet locations. Warranty: Beacon luminaires feature a 5 year limited warranty. Beacon LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays. LED drivers are covered by a 5 year limited warranty. PIR sensors carry a 5 year limited warranty from the sensor manufacturer. See Warranty Information on www.beaconproducts.com complete details and exclusions. Power/Lumens & Distribution Engine Wattage Delivered TM21 Calculated % Lumen Delivered Lumens Maint. LPW at 100,000 hrs (varies by optic) 24NB 27 2752-3014 105-115 96.19% 24NB 55 5138-5500 93-100 96.19% 36NB 80 6935-8215 93-103 94.87% 48NB 110 10240-10950 93-103 92.73% 60NB 136 12800-13700 93-103 85.79% TM21 is the framework for taking LM-80 data and making useful LED lifetime projections. Reported and Calculated Lifetimes shown are based on hours at the time of this printing. For current Reported and Calculated hours please contact factory or Beacon’s web-site. CCT (COLOR TEMP) Lumen Output Multipliers CRI (Color Rendering) 5000K = 1.0 min 67 CRI 4000K = .92 min 70 CRI 3000K = .75 min 80 CRI Due to our continued efforts to improve our products, product specifications are subject to change without notice. Fax: (941) 751-5535 SPECIFICATION