LED Troffer Conversion Kit - Precision

advertisement
TKD
LED Troffer Conversion Kit
Patent Pending
Product Information
Project Name
Type
Catalog Number
Date
SPECIFICATIONS
Features
• Retrofits prismatic & parabolic troffers with fixture depth greater than 3-1/8".
• Fully integrated reversible hinged optical assembly allows for rapid troffer conversion.
• Upgrade to modern full distribution architectural aesthetics providing
controlled soft, uniform light distribution without pixilation.
• Choice of four lumen packages and three dimming options available.
• Long-life, 60,000 hour LEDs at L80 (80% lumen maintenance)
reduces life cycle maintenance costs.
• Up to 101 lumens per watt.
• Low W/ft2 to meet the most restrictive lighting power density codes.
• Reduces job site waste by reusing existing fixture housing.
• Color Rendering Index (CRI) > 80.
• Available in both 2x4 and 2x2 configurations.
Construction
•
•
•
•
•
Conversion kit includes pre-wired LED door frame assembly, mounting rails and screws.
Luminaire retrofit is die formed, pre-painted white aluminum.
Acrylic lens features linear prisms sculpted into the surface for a distinct ribbed texture.
Hinges from either side for easy access to LED module and electrical components
Weight: 2x2 – 7 lbs. & 2x4 – 10 lbs.
Certifications
•
•
•
•
•
•
•
UL listed 1598, 1598C and cUL for Canada.
Luminaires bear appropriate listing labels.
Emergency-equipped fixtures labeled UL 924.
Adheres to LM79, LM80 and TM21 industry standards.
Maintains insulation contact (IC) rating of existing fixture.
DesignLights Consortium® (DLC) qualified.
Please refer to the DLC website for specific product qualifications
at www.designlights.org.
• Please refer to the Lighting Facts website for specific product
qualifications at www.lightingfacts.com.
Electrical
•
•
•
•
•
•
•
•
•
•
•
•
Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max)
Frequency: 50/60 Hz Nom. (47-63 Hz Min/Max)
Active Power Factor Correction
Power Factor: >0.90 @ full load, 100V through 277V
Inrush Current: 70 Amps max @ 220 VAC, cold start 25ºC
Harmonic Distortion: THD < 20% @ full load
Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit with self-recovery
Compliant to FCC Part 15 requirements for EMI/RFI emissions
NEC/CEC compliant ballast disconnect is standard
Standard surge protection: ANSI Std. C62.41-2002 Category A (2.5 kV)
Optional surge protection: ANSI Std. C62.41-2002 Category C High (10kA and 10kV)
Optional emergency battery pack
Application
• Ideal for Commercial Offices, Educational Facilities, Retail,
and Health Care Facilities.
• Suitable for use with most wired or wireless lighting control systems.
• Suitable for Dry or Damp Locations.
Warranty
• Five-year warranty. (Terms and Conditions Apply)
CERTIFICATION
ORDERING INFORMATION
–
MODEL
TKD Full
Distribution
LED
Conversion
Kit*
EXAMPLE TKD-2X4-LW-F-UL-40K-FRL
–
SIZE
2x2 2x2
Nominal
2x4 2x4
Nominal
–
LUMEN
OUTPUT
VL Very Low1
(2x4 Only)
XL Extra Low
LW Low
ML Medium
HL High
–
DRIVER
OUTPUT
F Fixed
DM 0-10v
Dimming2
DML 0-10v Line
Voltage
Dimming2
–
DRIVER
VOLTAGE
UL Universal
120-277 Volt
120 120 Volt
(For DML)
277 277 Volt
–
–
COLOR
TEMP
35K 3500
40K 4000
50K 5000
LENS
OTHER
FRL Frosted
EB Emergency
Ribbed
Lens
Battery
Backup
LSP Lighting
Surge
Protector
(For DML)
FOOTNOTES
* U.S. & Canada Patents Pending.
1. Non-DLC 40K and 50K.
2. Must be used in conjunction with lighting controls.
Contact factory for assistance.
Page 1/3 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
TKD
LED Troffer Conversion Kit
Patent Pending
PHOTOMETRIC DATA
PHOTOMETRIC DATA: TKD-2X4-LW-F-UL-40K-FRL
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
Luminaire
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
INDOOR CANDELA PLOT
ZONAL LUMEN SUMMARY
90
TKD-2X4-LW-F-UL-40K-FRL,
LED Troffer Conversion Kit
D255CQ42UNV-A
1.00
LED
4019
41
Recessed
N/A
0° = 1.20 90° = 1.20
Length: 3.71
Width: 0.88
Height: 0.00
Test: L0813316R01
Test Date: 08/14/13
80
356
70
Zone
Lumens
%Lamp
%Fixt
0-20
0-30
0-40
0-60
0-80
0-90
510
1067
1724
3021
3887
4019
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
12
26
42
75
96
100
712
60
1068
50
1424
0
10
20
30
AVG. LUMINANCE (Candela/Sq. M.)
40
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _
0.0
RCR
RC
RW
0
1
2
3
4
5
6
7
8
9
80
70
119
108
98
89
81
75
69
64
60
56
50
119
103
89
78
69
61
55
50
46
42
70
30
119
98
82
69
60
52
46
41
37
34
10
119
94
76
62
53
45
40
35
31
28
70
116
105
95
86
79
73
67
62
58
54
50
116
100
87
76
67
60
54
49
45
41
50
30
116
96
80
68
59
52
46
41
37
33
10
116
92
75
62
52
45
39
35
31
28
50
111
96
83
73
65
58
53
48
44
40
30
111
93
78
66
58
50
45
40
36
33
Average Luminance Angle
COEFFICIENTS OF UTILIZATION (%)
0
10
111
89
73
61
52
45
39
35
31
28
0
100
82
67
56
48
41
36
32
29
26
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
0 1424
5 1412
10 1386
15 1343
20 1285
25 1212
30 1126
35 1031
40 927
45 820
50 711
55 603
60 506
65 406
70 307
75 217
80 133
85
63
22.5
45.0
67.5
90.0
1424
1413
1385
1342
1282
1210
1128
1037
940
839
736
633
538
436
342
252
166
85
1424
1415
1385
1339
1279
1209
1132
1051
966
878
788
699
615
528
437
338
235
123
1424
1413
1380
1332
1271
1205
1134
1061
986
909
831
755
682
604
508
408
304
170
1424
1411
1377
1328
1269
1203
1134
1064
992
920
847
775
707
630
535
439
332
192
LUMEN PACKAGE OPTIONS
4000K DETAILS
3500K DETAILS
Proposed
System
TKD-2X2-XL
TKD-2X2-LW
TKD-2X2-ML
TKD-2X2-HL
TKD-2X4-VL
TKD-2X4-XL
TKD-2X4-LW
TKD-2X4-ML
TKD-2X4-HL
Light Source
Quantity & Type
1
1
1
1
1
1
1
1
1
TKD XL Engine
TKD LWEngine
TKD ML Engine
TKD HL Engine
TKD VL Engine
TKD XL Engine
TKD LWEngine
TKD ML Engine
TKD HL Engine
CRI
CCT
Lumens
Per Fixture
Input
Watts
Lumens
Per Watt
CCT
Lumens
Per Fixture
Input
Watts
Lumens
Per Watt
>80
>80
>80
>80
>80
>80
>80
>80
>80
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
2,091
2,544
3,237
4,632
2,793
3,076
3,989
4,702
6,573
21
27
36
52
25
30
41
51
72
99
94
90
89
113
101
98
93
91
4000K
4000K
4000K
4000K
4000K*
4000K
4000K
4000K
4000K
2,082
2,589
3,421
4,851
2,849*
3,137
4,020
4,747
6,863
21
28
36
52
25*
32
41
51
72
98
91
95
93
113*
99
97
94
95
Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards.
*Lumen values calculated with 1.02 multiplier based on LED manufacturer data.
Page 2/3 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
TKD
LED Troffer Conversion Kit
Patent Pending
MINIMUM DIMENSIONS OF EXISTING FIXTURE OPENING
2X4 Min. Dimension.
2X2 Min. Dimension.
14.41 Min.
14.41
3.125
Min.
3.125
Min.
.65
22.50
Min. Dimension at
Fixture Opening
45.81
Min. Inside Dimension
46.81
Min. Inside Dimension
at Fixture Opening
.65
22.50
Min. Dimension at
Fixture Opening
22.81
Min. Inside Dimension
at Fixture Opening
24.00
48.00
FIT AND FUNCTION
Minimum dimensional requirements are above but Precision-Paragon[P2] recommends
a trial installation prior to ordering project quantities. TKD Coversion Kits are designed
to fit into most parabolic and lensed-recessed troffers mounted in T-grid installation.
Page 3/3 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
Download