m u N b o c M JE P 3 0 6 Ca -U e klb S & n rd o E :O IL A H P N D Y IT n R iO s rs,c.g e @ e ,jN E IV R G o m l.c k s n a rd jN O 4 ) 0 7 ( T R H C 7 R 4 5 O X A F 1 S 0 2 ,( 8 4 ) 0 7 O G J A 6 2 R 0 3 D 1 7 0 N &S A K A G N N E L I E R S IN C . 100 6"∅ A AIR DEVICE TAG, TYPE "A", BALANCE FOR 100 CFM, 6" ROUND NECK BDD BACK DRAFT DAMPER ABBREVIATION DESCRIPTION ABBREVIATION --- 1000 BTUH/HR MBH BDD ABOVE CEILING A/C ABOVE FINISHED FLOOR AFF HVAC GENERAL NOTES DUCT SMOKE DETECTORS: 1. ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE REQUIREMENTS OF THE 2009 INTERNATIONAL MECHANICAL CODE, THE 2009 INTERNATIONAL BUILDING CODE, THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE, STATE AND LOCAL AMENDMENTS, NFPA 90A, 101, UNDERWRITERS LABORATORIES (OR ETL) AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 1. ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE SHALL BE INSTALLED WITH A SMOKE DETECTOR IN THE RETURN DUCTWORK. DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN AIR PATH OF AIR DISTRIBUTION SYSTEMS UTILIZING A COMMON SUPPLY AND/OR RETURN AIR PLENUM WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM. 2. THE LOCATIONS, ARRANGEMENT AND EXTENT OF EQUIPMENT, PIPING, SUPPORTS, DEVICES, CONDUIT, AND OTHER APPURTENANCES RELATED TO THE INSTALLATION OF THE MECHANICAL AND ELECTRICAL WORK SHOWN ARE APPROXIMATE. THE DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE THE DRAWINGS, BUT REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS OF BUILDING COMPONENTS. SHOULD A CONFLICT EXIST BETWEEN THE ARCHITECTURAL AND ENGINEERING DRAWINGS REGARDING DIMENSIONS, SCALE, ETC., NOTIFY THE ARCHITECT IMMEDIATELY. 2. THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, MOUNTED IN THE DUCT BY THE MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. 3. MATERIALS, EQUIPMENT OR LABOR NOT INDICATED, BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE INSTALLATION SHALL BE PROVIDED. THE DRAWINGS AND SPECIFICATIONS DO NOT UNDERTAKE TO INDICATE EVERY ITEM OF MATERIAL, EQUIPMENT OR LABOR REQUIRED TO PRODUCE A SAFE, COMPLETE AND PROPERLY OPERATING SYSTEM. 1. SUPPLY, RETURN AND O.A. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS, LATEST EDITION. ALL JOINTS AND SEAMS IN ALL SHEETMETAL DUCTWORK SHALL BE SEALED WITH DUCT SEALER. 4. PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. 2. ALL OPEN ENDED DUCTS AND FAN OUTLETS SHALL HAVE ½” X ½” HARDWARE CLOTH AFFIXED TO THE OPENING. 3. EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL (G 90 MINIMUM) CONSTRUCTED TO SMACNA STANDARDS AND SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. 4. ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL BE PER SMACNA STANDARDS. 5. FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M-KE (U.L. 181 LISTED, CLASS 1 FLEXIBLE AIR DUCT) OR EQUAL. PROVIDE MINIMUM INSULATION VALUE OF R-6; R-8 WHEN LOCATED OUTSIDE THE THERMAL ENVELOPE OF THE BUILDING, OR GREATER WHERE REQUIRED BY APPLICABLE ENERGY CODE. AIR CONNECTORS ARE NOT ACCEPTABLE. FLEX DUCT DIAMETER SHALL MATCH DEVICE NECK DIAMETER. PROVIDE ROUND GALVANIZED STEEL DUCT RUNOUTS TO MAINTAIN A MAXIMUM FLEXIBLE DUCT LENGTH OF 8'-0". FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. 6. ROUND AND FLEXIBLE SUPPLY AIR DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH A CONICAL TYPE SPIN-IN FITTING WITH MANUAL VOLUME DAMPER (EXCEPT WHERE INSTALLED ABOVE INACCESSIBLE CEILINGS, THE DAMPER SHALL BE OMITTED AND PROVIDED IN THE AIR DEVICE NECK). 7. TAPE, BED AND SEAL AIR TIGHT ALL PENETRATIONS FROM RETURN AIR PLENUMS TO NON RETURN AIR PLENUMS THAT ARE REQUIRED DUE TO DUCTWORK, PIPING OR OTHER ITEMS. 8. DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. 9. EXTERNAL STATIC PRESSURE (ESP) DOES NOT INCLUDE COIL, CASING OR FILTER PRESSURE DROP. 10. PROVIDE ALL OUTDOOR AIR INTAKES AND EXHAUST OPENINGS WITH MOTORIZED OR GRAVITY DAMPERS IN ACCORDANCE WITH THE LOCAL ENERGY CODE. DAMPERS SHALL CLOSE WHEN THE VENTILATION SYSTEM IS NOT OPERATING. 11. LOCATIONS OF GRILLES, REGISTERS, AND DIFFUSERS SHOWN ON THE DRAWINGS ARE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, ETC. AND ARCHITECTURAL REFLECTED CEILING PLAN. 12. WHERE BALANCING DAMPERS CANNOT BE ACCESSED FROM BELOW THE CEILING, PROVIDE A REMOTE OPERATED DAMPER; YOUNG REGULATOR OR EQUAL. 13. FLEXIBLE DUCT CONNECTORS SHALL BE USED TO CONNECT DUCTWORK AND PLENUMS TO FAN-ROTATING EQUIPMENT; DURODYNE EXCELON OR APPROVED EQUAL. FLEXIBLE CONNECTORS EXPOSED TO THE WEATHER SHALL BE UV AND OZONE RESISTANT. FABRICS, COATING AND ADHESIVES SHALL BE TESTED IN ACCORDANCE WITH UL 701 AND HAVE A FLAME SPREAD/ SMOKE DEVELOPED RATING OF 25/50. mO u N b o -b n C c P M E J 3 0 6 P H :a IL U A le k S & n rd o E R Y N iT .g ,Ic rs e D O IG jN E @H e ,s V R T 4 ) 0 7 ( m l.c k s n a rd o O N j 5 R 7 4 C2 1 0 X A R F O J O 8 4 ) 0 7 ( S , R D 6 2 A G 0 N A 1 &S 7 0 3 K A G N N E L I E R S IN C . DN DUCT DROP --- R DUCT RISE --- DUCT SIZE - FLAT OVAL --- BOTTOM OF DUCT BOD DUCT SIZE - RECTANGULAR (OR 12/10) --- CEILING RADIATION DAMPER CRD DUCT SIZE - ROUND --- CLEAN OUT CO DUCT SMOKE DETECTOR --- CONDENSATE DRAIN CD DOWN DN DRY BULB DB 8 12x10 8"∅ DUCT TRANSITION FCU -- EQUIPMENT DESIGNATION H M T S --- FIRE DAMPER (HORIZONTAL) FD FIRE DAMPER (VERTICAL) FD ACCESS PANEL (REFER TO ARCHITECTURAL DWGS.) AP ELECTRIC UNIT HEATER EUH ELECTRIC WALL HEATER EWH 5. FLEXIBLE DUCT --- ENTERNING AIR TEMPERATURE EAT FLEXIBLE DUCT CONNECTOR --- EXHAUST AIR (ENVIRONMENTAL AIR) EA EA EXHAUST FAN EF ESP HUMIDISTAT H LINED DUCT --- EXTERNAL STATIC PRESSURE MANUAL VOLUME DAMPER (RECTANGULAR DUCT) MVD GAS FIRED UNIT HEATER MANUAL VOLUME DAMPER (ROUND DUCT) MVD HEAT PUMP MOTORIZED DAMPER MD GUH LEAVING AIR TEMPERATURE NOT TO SCALE NTS RETURN / EXHAUST AIR DUCT TURNED UP --- OUTSIDE AIR OA RETURN / EXHAUST AIR GRILLE (CEILING) --- PRESSURE DROP PD SIDEWALL SUPPLY REGISTER OR GRILLE --- RETURN AIR RA SIDEWALL RETURN AIR REGISTER OR GRILLE ----- ROOF TOP UNIT SLOT DIFFUSER --- SQUARE FEET SF SQUARE CEILING DIFFUSER --- STATIC PRESSURE (IN. W.C.) SP SUPPLY AIR DUCT TURNED DOWN --- SUPPLY AIR SA SUPPLY AIR DUCT TURNED UP --- SUPPLY GRILLE SG THERMOSTAT/TEMPERATURE SENSOR TSTAT SUPPLY REGISTER SR TURNING VANES --- UNLESS NOTED OTHERWISE UNO WALL CAP (EA OR OA) --- WALL LOUVER WL WATER COLUMN OR WATER GAUGE WALL LOUVER (EXHAUST) WL WET BULB --- --- --- --- 7. ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 8. ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 4-YEAR MANUFACTURER'S WARRANTY FOR A 5-YEAR TOTAL WARRANTY. 9. FOR EXACT LOCATION OF OUTDOOR AIR CONDITIONING UNITS, SEE ARCHITECTURAL DRAWINGS. 10. INSTALL ROOF MOUNTED OUTDOOR AIR CONDITIONING EQUIPMENT LEVEL ON 2" (MIN.) THICK POLYPROPYLENE EQUIPMENT PAD 4" LARGER THAN OUTDOOR UNIT FOOTPRINT; DIVERSITECH "E LITE PAD" OR APPROVED EQUAL. MOUNT ALL EQUIPMENT ON ½” THICK NEOPRENE PADS (MINIMUM OF 4 PADS PER UNIT). ALL ROOFTOP MOUNTED EQUIPMENT SHALL BE INSTALLED PER DETAILS AND AS RECOMMENDED BY THE MANUFACTURER. 11. 12. 13. WL --- ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. RTU WALL LOUVER (INTAKE) --- 6. LAT --- --- WC or WG M-101 M-102 M-103 M-104 M-201 M-202 M-301 M-302 14. 15. 16. WB --- --- --- --- --- --- --- --- --- --- DRAWINGLIST‐HVAC SHEETNUMBER SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE: ALL EQUIPMENT SCHEDULED OR SPECIFIED ON THE DRAWINGS; DUCTWORK DRAWN TO 1/4" SCALE OR THE SCALE SHOWN ON THE DRAWINGS; PARKING GARAGE CO/NO2 MONITORING AND CONTROL SYSTEM LAYOUT INCLUDING SENSOR LOCATIONS, SEQUENCE OF OPERATION AND PRODUCT DATA; MECHANICAL VENTILATION REFRIGERANT PIPING AND CONTROL WIRING SCHEMATICS CERTIFIED BY THE AIR CONDITIONING EQUIPMENT MANUFACTURER. FAILURE TO SUBMIT REFRIGERANT PIPING DRAWINGS SHALL BE CAUSE FOR REJECTION OF THE ENTIRE SUBMITTAL. LONG LINE REFRIGERANT PIPING APPLICATIONS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S CURRENT SPLIT SYSTEM LONG-LINE APPLICATION GUIDELINE. SHOP DRAWINGS SHALL BE SUBMITTED SIMULTANEOUSLY IN ONE PACKAGE WITH EACH ITEM CLEARLY NOTED BY THE TAG USED ON THE DRAWINGS. HP RETURN / EXHAUST AIR DUCT TURNED DOWN MECHANICAL EQUIPMENT WITH SERVICE AND AIRFLOW CLEARANCES (AS REQUIRED BY THE MANUFACTURER) AIR DISTRIBUTION: PORTIONS OF DUCTWORK AND PIPE INSULATION VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. MOUNT TOP OF THERMOSTATS AND SENSORS 46" AFF UNLESS NOTED OTHERWISE. PROVIDE CLEAR LOCKING GUARD ASSEMBLIES FOR ALL PUBLIC AREA AND CLASSROOM THERMOSTATS. COORDINATE THERMOSTAT LOCATIONS WITH OTHER TRADES. ALL THERMOSTATS SHALL BE ADA COMPLIANT. ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, PIPING, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. PROVIDE ACCESS PANELS IN NON-ACCESSIBLE CEILINGS AND IN WALL STRUCTURE TO ALLOW ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEMS. ACCESS PANELS IN CEILING AND WALLS SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS OR NECESSARY TO ACCESS DAMPERS, VALVES, ETC. COORDINATE EXACT LOCATION OF ALL ACCESS PANELS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS. ALL MECHANICAL EQUIPMENT SHALL BE LABELED WITH A 2” HIGH SEMI-RIGID PLASTIC LAMINATE NAMEPLATE WITH 1” HIGH WHITE LETTERS ON A BLACK BACKGROUND SECURELY AFFIXED TO THE EQUIPMENT. THE NAMEPLATE SHALL SHOW THE EQUIPMENT TAG USED ON THESE DRAWINGS. 17. REFER TO ARCHITECTURAL PLANS FOR FLOOR AND CEILING ASSEMBLY UL RATINGS AND DETAILS. 18. ALL MATERIALS EXPOSED WITHIN HVAC PLENUMS SHALL HAVE A FLAME-SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED RATING INDEX OF NOT MORE THAN 50 UNLESS OTHERWISE ALLOWED BY CODE. 16. 14. EXPOSED INTERIOR DUCTWORK TO BE PAINTED SHALL HAVE ALL EXPOSED SURFACES (INCLUDING HANGER STRAPS) COATED WITH A "PAINT GRIP" FINISH FOR FIELD PAINTING. AS AN OPTION, MILL PHOSPHATIZED STEEL DUCTWORK MAY BE USED. LINE OR INSULATE PER HVAC GENERAL NOTES OR SPEC SECTION 23 07 00. 15. EXPOSED DOUBLE-WALL, INSULATED ROUND OR FLAT OVAL DUCT AND FITTINGS SHALL BE BY McGILL AIRFLOW LLC (OR EQUAL BY LINDAB, INC OR SEMCO, INC.). DUCT SYSTEM SHALL HAVE SPIRAL LOCKSEAM (OR WELDED) GALVANIZED SHEET METAL OUTER SHELL, 1” THICK COATED ACOUSTICAL LINER, AND A PERFORATED SHEET METAL INNER LINER. SHEETNAME KEY PLAN A B ISSUE FOR PERMIT BID & CONSTRUCTION PROTECT DUCTS EXPOSED IN FINISHED SPACES FROM BEING DENTED, SCRATCHED, OR DAMAGED. TRIM DUCT SEALANTS FLUSH WITH METAL TO CREATE A SMOOTH AND UNIFORM EXPOSED BEAD. TWO-PART TAPE SEALING SYSTEMS ARE NOT ALLOWED. REPAIR OR REPLACE DAMAGED DUCTWORK AND FINISH WORK THAT DOES NOT COMPLY WITH THESE REQUIREMENTS. INSULATION: 19. THE FIRE SPRINKLER CONTRACTOR SHALL INSTALL AND LOCATE ALL FIRE SPRNKLER PIPING TO PREVENT PIPING FROM THE POTENTIAL OF FREEZING. THE FIRE SPRINKLER CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT AND COORDINATE WITH THE MECHANICAL AND ELECTRICAL CONTRACTORS IF HEATING IS REQUIRED. 20. UNLESS NOTED OTHERWISE, THE ROOF CURB SHALL BE FURNISHED WITH THE EQUIPMENT IT SUPPORTS (SUBMIT WITH SHOP DRAWINGS). VIBRATION/SOUND ATTENUATING ROOF CURBS (WHERE SCHEDULED OR NOTED) SHALL BE MASON RSC-A (2½“) OR EQUAL WITH ACOUSTICAL PACKAGE. 21. DUCTWORK AND PIPING SHALL NOT BE INSTALLED IN ELECTRICAL ROOMS, TELECOMM ROOMS, OR ELEVATOR EQUIPMENT ROOMS EXCEPT FOR DUCTWORK AND PIPING SERVING THAT SPECIFIC ROOM. DUCTWORK AND PIPING SHALL NOT BE ROUTED ABOVE ELECTRICAL EQUIPMENT PER THE NATIONAL ELECTRICAL CODE ARTICLE 110. 1. 1. AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE TESTED, ADJUSTED, AND BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. SUBMIT CERTIFIED (AABC OR NEBB) TEST AND BALANCE REPORT TO THE ARCHITECT FOR APPROVAL. 2. VENTILATION AIR DISTRIBUTION SYSTEMS (OUTDOOR AIR AND EXHAUST AIR) SHALL BE BALANCED TO ACHIEVE THE AIRFLOW RATES INDICATED ON THE DRAWINGS. THESE AIRFLOW RATES SHALL BE CONSIDERED MINIMUM RATES. THE MEASURED AIR BALANCE TOLERANCE FOR BOTH OUTDOOR AIR AND EXHAUST AIR RATES SHALL BE 0% TO +10%. b. INDOOR EXPOSED ROUND, SPIRAL AND OVAL SUPPLY AND RETURN AIR DUCT SHALL BE LINED WITH 1” THICK ROUND DUCT LINER (MINIMUM R-4), JOHNS MANVILLE SPIRACOUSTIC PLUS OR EQUAL. c. DUCT LINER FOR ACOUSTICS: LINE ALL SHEETMETAL DUCTWORK A MINIMUM OF 15'_0" (OR AS INDICATED) UPSTREAM AND DOWNSTREAM OF ALL ROOFTOP UNITS, AND AIR HANDLING UNITS. DUCT LINER SHALL BE 1½” THICK, (MINIMUM R-6 OR GREATER WHERE REQUIRED BY APPLICABLE ENERGY CODE), JOHNS MANVILLE LINACOUSTIC RC OR EQUAL. THE LEADING EDGE OF THE DUCT LINER SHALL HAVE A SHEETMETAL NOSING. LINED DUCTWORK DOES NOT REQUIRE ADDITIONAL EXTERIOR INSULATION WHERE LINER MEETS REQUIRED R-VALUES. d. REFER TO ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS FOR PAINTING OF DUCTWORK, INSULATION, ETC. IN EXPOSED INTERIOR AREAS. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR SUBMITTING SHOP DRAWINGS, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. SHOP DRAWING SUBMITTALS SHALL CLEARLY STATE THAT THE ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT HAS BEEN COORDINATED WITH THE ELECTRICAL CONTRACT DOCUMENTS AND THE ELECTRICAL CONTRACTOR. 2. ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH DISCONNECT SWITCHES AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON-FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND THE ELECTRICAL DRAWINGS. 3. PROVIDE ALL SYSTEM CONTROLS AND ASSOCIATED CONTROL AND INTERLOCK WIRING FOR COMPLETE AND OPERABLE SYSTEMS. 120 VOLT AND HIGHER WIRING SHALL BE MC CABLE OR IN CONDUIT IN ACCORDANCE WITH LOCAL CODES AND THE MATERIALS AND INSTALLATION REQUIREMENTS OF DIVISION 26 - ELECTRICAL. 4. COORDINATE POWER AND FIRE ALARM REQUIREMENTS OF ALL COMBINATION FIRE/SMOKE DAMPERS AND SMOKE DAMPERS WITH THE ELECTRICAL CONTRACTOR. 5. 6. 7. ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, DEVICES, ETC.) NOT INDICATED ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED ACCORDING TO CODE REQUIREMENTS. UNLESS NOTED OTHERWISE, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED WITH THE EQUIPMENT IT SERVES AND INSTALLED BY THE MECHANICAL CONTRACTOR. MOTOR STARTERS FOR HVAC EQUIPMENT SHALL BE FURNISHED WITH THE MOTOR OR APPARATUS WHICH IT OPERATES. MOTOR STARTER INSTALLATION SHALL BE BY THE DIVISION 26 CONTRACTOR. ROUTING OF PIPING AND DUCTWORK SHALL BE COORDINATED WITH THE ELECTRICAL CONTRACTOR AND ALL OTHER TRADES DURING THE SUBMITTAL AND LAYOUT PHASE. PIPING AND DUCTWORK SHALL NOT BE ROUTED THROUGH THE DEDICATED ELECTRICAL SPACE ABOVE EACH LOAD CENTER. PIPE INSULATION: a. REFRIGERANT SUCTION PIPING INSULATION SHALL BE FLEXIBLE ELASTOMERIC TUBING, AP/ARMAFLEX PIPE INSULATION WITH REINFORCED LAP SEAL AS MANUFACTURED BY ARMACELL OR EQUAL. INSULATION THICKNESS SHALL BE PER SPECIFICATION 23 23 00. INSULATION SHALL BE SLID OVER PIPING FROM ONE END BEFORE PIPE ENDS ARE JOINED AND SHALL NOT BE SLIT OR CUT. ALL JOINTS AND SEAMS SHALL BE SEALED WEATHER-TIGHT. FINISH COAT FOR FLEXIBLE ELASTOMERIC INSULATION INSTALLED OUTDOORS SHALL BE WATER-BASED LATEX ENAMEL DESIGNED FOR USE OVER ALL FORMS OF FLEXIBLE ELASTOMERIC INSULATION. FINISH COAT SHALL PROVIDE A PROTECTIVE FINISH SUITABLE TO BOTH INDOOR AND OUTDOOR APPLICATIONS, FORMULATED FOR COLD WEATHER FLEXIBILITY TO RESIST CRACKING AND WEATHER-RESISTANT TO ULTRAVIOLET (UV) AND OZONE. COATING SHALL BE ARMAFLEX WB FINISH OR EQUIVALENT. MECHANICAL/ELECTRICAL COORDINATION: 1. DUCT INSULATION: a. DUCT WRAP SHALL BE UL LISTED FIBERGLASS BLANKET INSULATION WITH FOIL VAPOR BARRIER, JOHNS MANVILLE MICROLITE XG OR EQUAL. PUNCTURES AND TEARS IN THE FOIL JACKET SHALL BE PATCHED WITH FOIL TAPE TO MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER. INSULATE SHEET METAL DUCTWORK IN THE THICKNESSES AND DENSITIES AS LISTED BELOW: i. SHEET METAL SUPPLY AND OUTSIDE AIR DUCTWORK: 2” THICK, 1 LB/FT3 DENSITY, R-6 MINIMUM INSTALLED. ii. SHEET METAL RETURN DUCTWORK IN NON-AIR CONDITIONED AREAS (SUCH AS INTERSTITIAL SPACES AND FLOOR/CEILING ASSEMBLIES): 2" THICK, 1 LB/FT3 DENSITY, R-6 MINIMUM INSTALLED. TESTING, ADJUSTING AND BALANCING GENERAL NOTES AND LEGEND - MECHANICAL SCHEDULES - MECHANICAL DETAILS - MECHANICAL DETAILS - MECHANICAL FLOOR PLAN AREA A - MECHANICAL FLOOR PLAN AREA B - MECHANICAL ROOF PLAN AREA A - MECHANICAL ROOF PLAN AREA B - MECHANICAL 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 DESCRIPTION P 3 0 6 CU M E c m u N b o J H O :P IL A a l N k S & n d o r-E e b D Y IT R O n i R .g ,c rs e ,jN E IV G O @ e s N 4 ) 0 7 ( T H m l.c k s n a rd o j R C 7 R 4 5 O X A F 1 0 2 S ,( 8 4 ) 0 7 O A J G 6 2 R D 3 0 1 7 0 N &K A S A G IN E N E L R S IN C . CENTRAL BAPTIST CHURCH CHILDRENS BUILDING SYMBOL 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 HVAC NOTES C c P mO u N b o M JE 3 0 6 P H :A IL U a - Y e klb S & n rd o E R N D IT O n i IG rs,c.g e jR E @ e ,s V N H T ( 4 ) 0 7 m l.c k s n a rd o O N j 5 R 7 4 C2 1 0 R X A F O J O S 8 4 ) 0 7 ( , R D 6 2 A G 0 N A 1 &S 7 0 3 K A G N N E L I E R S IN C . b. INSULATE ALL CONDENSATE DRAIN PIPING WITH FIBERGLASS PIPE INSULATION WITH VAPOR BARRIER JACKET; JOHNS MANVILLE MICRO-LOK OR APPROVED EQUAL. FITTINGS, VALVES AND PIPING SPECIALITIES SHALL BE PROVIDED WITH FORMED FITTING COVERS BY PROTO PVC CORPORATION. SEE SPECIFICATIONS FOR INSULATION THICKNESSES AND ADDITIONAL INFORMATION. ALL EXPOSED INSULATED PIPING BELOW 10'_0" AFF SHALL BE PROTECTED BY A CORRUGATED ALUMINUM JACKET WITH ALUMINUM BANDS 3'-0" O.C. 1991 FM 158, BRYAN, TX 77845 HVAC LEGEND PIPING: 1. REFRIGERANT PIPING SHALL BE TYPE L OR ACR (AIR CONDITIONING AND REFRIGERATION FIELD SERVICE) COPPER TUBING WITH BRAZED JOINTS. 2. REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS. 3. CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO THE NEAREST PLUMBING DRAIN. CONDENSATE PIPING SHALL BE SCHEDULE 40 PVC (EXCEPT INSULATED TYPE M COPPER IN HVAC PLENUMS). CONDENSATE SHALL BE PUMPED AS REQUIRED. PVC EXPOSED TO THE WEATHER SHALL BE PAINTED WITH A LIGHT COLORED ACRYLIC OR LATEX ULTRAVIOLET (UV) AND OZONE INHIBITOR PAINT THAT IS CHEMICALLY COMPATIBLE WITH PVC. 4. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM THE TOP CHORDS OF THE JOISTS. No. Date Revision RAC Drawn JRM Checked WAS Approved GENERAL NOTES AND LEGEND MECHANICAL Project No. Date Last Revision 15187.00 05/11/2016 M-101 printed5/11/2016 12:25:59 PM MANF. EQUIP SERIES MORGANIZER MODELNO. OCD181E_TXV A112,A113,A114,A115,A116 OCD181E_TXV A107,A108,A109,A110,A111 OE360B4DH_100 A119,A117,A118,A122,A120,A121 OE420B4DH_100 A124,A125,A126,A123,A127,A128,A129 OHC120E A101,A102,A103,A104,A105,A106,104,105 A100 OCD181E_TXV B166,B168,B167,112,A135,A134,A133,B103,B 102,B101,108,A132 107 100,101 OHC120E 101 101,115 B100 OE360B4DH_100 B156,B165,B159,B164,B160,B161,B163,B162, B132,B133,B131,B130,B134,B135 OCD151E_TXV B114,B113,B115,B112,B116,B117 OHC120E B104,B105,B106,B107 OCD211E_TXV B155,B154,B153,B149,B147,B145,B146 B139,B138,B137,B141,B140,B144,B143,B142, B100M OCD151E_TXV B136,B126,B125,B124,B123,B127,B128,B129 OCD151E_TXV B121,B120,B119,B118,B110,B109,B108 RTU 1 RTU 2 RTU 3 RTU 4 RTU 5 RTU 6 RTU 7 TRANE TRANE TRANE TRANE TRANE TRANE TRANE THD181 THD181 TED360 TED420 THC120 THC120 THD181 RTU 8 RTU 9 RTU 10 RTU 11 RTU 12 RTU 13 TRANE TRANE TRANE TRANE TRANE TRANE THC102 THD150 THC120 THC092 THD240 TED360 RTU 14 RTU 15 RTU 16 RTU 17 TRANE TRANE TRANE TRANE THD151 THC120 THD211 THC060 RTU 18 RTU 19 TRANE TRANE THD151 THD151 SYSTEM TYPE AREASERVED HEATING EFFICIENCY EER/IEER SEER KW FILTERS WEIGHT NO.OF MERV EAT (LB) CONTROL RATING (˚F) STAGES ACCESSORIES CV CV CV CV CV CV CV 3600 3550 7800 8200 2200 3400 3200 1320 1310 2250 2390 850 520 1280 3600 3550 7800 8200 2200 3400 3200 3 3 7 1/2 7 1/2 3 3/4 3 3/4 3 1.0 1.0 1.0 1.0 1.0 1.0 1.0 15 15 30 35 10 10 15 170.9 169.8 320.5 363.9 108.2 105.7 165.2 107.1 106.4 214.5 242.1 69.1 87.7 103.4 84.2 84.4 82.2 82.3 84.7 78.8 85 70 70 69 69 70 65 70 12 12 12 12 12.4 12.4 12 - 54 36 90 90 27 27 36 52.2 51.9 55.6 55.5 51.4 62.2 50.8 SCR 2 SCR SCR 2 2 2 7 7 7 7 7 7 7 3000 3000 4100 4100 1800 3000 3000 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,10,11,12,13,14,15 1,2,3,4,5,6,7,8,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,10,11,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 CV CV CV CV CV CV 3000 5000 2300 2700 7200 6500 560 830 770 700 690 3130 3000 5000 2300 2700 7200 6500 3 3/4 3 3 3/4 3 3/4 7 1/2 7 1/2 1.0 1.0 1.0 1.0 1.0 1.0 8.5 12.5 10 7.5 20 30 93.8 147 109.2 87 236.6 314.4 69.8 113.2 67.2 62 156.9 221 79.7 79.2 83.4 81.5 77.5 87.2 67 67 70 69 65 72 12.5 12.1 12.4 12.6 11.0 12 - 27 54 27 27 72 90 60.0 60.9 53.6 56.9 59.6 47.0 2 SCR 2 2 SCR SCR 7 7 7 7 7 7 1500 3000 1800 1500 3000 4100 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,10,11,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 CV CV CV CV 2100 2300 3650 1600 1220 1030 1620 170 2100 2300 3650 1600 3 3 3/4 5 3/4 1.0 1.0 1.0 1.0 12.5 10 17.5 5 127.5 132.9 188 58 82.7 71.2 125 40 87.2 86.2 86.3 77.9 72 72 72 65 12.1 12.4 11.8 - 14.2 36 27 54 12 46.7 48.7 48.7 62.6 2 2 SCR 2 7 7 7 7 3000 1800 3000 1000 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,13,14,15 CV CV 2730 2950 1140 1080 2730 2950 3 3 1.0 1.0 15 12.5 135.5 131.4 91 79.8 85.4 85.8 70 70 12 12.1 - 36 36 49.5 49.2 2 2 7 7 3000 3000 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 TAG SUPPLYFAN NETCOOLING AIRFLOW(CFM) CAPACITY(MBH) EAT(˚F) MAX ESP MOTOR OUTSIDEAIR (INWC) NOM TOT TOTAL SENS DB WB HP TONS MIN MAX 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 ROOFTOPUNIT(ELECTRICHEAT) NOTES: (APPLIES TO ALL UNITS). A. SCHEDULED COOLING CAPACIITY BASED ON THE FOLLOWING OUTDOOR AMBIENT TEMPERATURE: 100 ˚F DB B. REFRIGERANT SHALL BE R-410A. C. ALL RTU'S WITH CAPACITIES 7.5 TONS AND HIGHER SHALL BE PROVIDED WITH MULTIPLE COMPRESSORS AND MINIMUM OF 2 INDEPENDENT REFRIGERANT CIRCUITS. D. RETURN AND OUTSIDE AIR DAMPERS SHALL BE CLASS 1 LOW-LEAKAGE TYPE. E. PROVIDE CRANKCASE HEATERS ON ALL UNITS 6 TONS AND LARGER. F. RTU'S SHALL BE PROVIDED WITH 2" PLEATED DISPOSABLE FILTERS, CONDENSATE OVERFLOW SWITCH IN PRIMARY DRAIN PAN, MOTORIZED MODULATING OUTSIDE AIR DAMPER, COMPRESSOR ANTI-RECYCLE CONTROLS, SINGLE POINT POWER CONNECTION, COOLING OPERATION DOWN TO 40˚F, 14" HIGH INSULATED ROOF CURB WITH BASE SLOPED TO MATCH ROOF PITCH. ACCESSORIES: KEY PLAN 1. CONTROLS CONTRACTOR TO PROVIDE PROGRAMMABLE THERMOSTATS. 2. LOCKING THERMOSTAT COVER. 3. BACnet COMPATIBLE BAS CONTROLLER. 4. POWERED EXHAUST FOR ECONOMIZER RELIEF. 5. UNIT MOUNTED DISCONNECT. 6. SMOKE DETECTORS. MOUNT IN RETURN AIRSTREAM. 7. MODULATING HOT GAS RE-HEAT ADAPTIVE DEHUMIDIFICATION SYSTEM, CONTROLS. 8. HOT GAS BYPASS. INSTALL ON LEADING COMPRESSOR ON 2-STAGE UNITS. 9. KINETICS KNM-100C SOUND BARRIER MATERIAL INSIDE OF ROOF CURB AND ON TOP OF ROOF DECK. 10. GFCI 15 AMP CONVENIENCE OUTLET POWERED ON LINE SIDE OF DISCONNECT. 11. PHASE MONITORING PROTECTION. 12. RTU DEMAND CONTROL VENTILATION WIRING AND CONTROLS. PROVIDE WITH RETURN DUCT MOUNTED CO2 SENSORS AND ADDITIONAL SENSORS WHERE INDICATED. 13. INTEGRATED DIFFERENTIAL ENTHALPY TYPE ECONOMIZER, SIZED FOR 100% SUPPLY AIR CAPACITY, CAPABLE OF SIMULTANEOUS ECONOMIZER AND COMPRESSOR OPERATION, AND INTAKE HOOD. 14. CONDENSER COIL HAIL GUARDS. 15. PROVIDE MANUFACTURER STARTUP. A B EQUIPMENT SELECTIONS BASED ON PRODUCTS INDICATED. SUBJECT TO COMPLIANCE WITH ALL PRODUCTS, EQUAL PRODUCTS BY: CARRIER, LENNOX, DAIKIN. CU 1 CU 2 CU 3 CU 4 WAH 1 WAH 2 WAH 3 WAH 4 MODELNO. TOTALCFM RK18NMVJU RK24NMVJU RK18NMVJU RK18NMVJU FTK18NMVJU FTK24NMVJU FTK18NMVJU FTK18NMVJU MINO.A. CFM MAXFAN HP MBHTOT COOL MBHSENS COOL MINSEER ACCESSORIES TAG MODELNO. AREA SERVED TOTALCFM OUTDOOR AIRCFM ESP (IN.WG.) MBHTOTAL COOL MBHSENS COOL MBHINTL HEAT MAXFAN HP AUXHEAT KW MINSEER MINHSPF NOTES/ ACCESSORIES - - 18 24 18 18 18 24 18 18 14.4 21.2 14.4 14.4 14.4 21.2 14.4 14.4 18 18 18 18 1,3 1,3 1,3 1,3 2,4 2,4 2,4 2,4 AH 1 HP 1 GAM5024 4TWR4024 102 - LIBRARY - 750 - 120 - 0.8 - 23 23 17.7 17.7 21.5 21.5 1/2 - 5 - 14 14 8.5 8.5 1,2,3,4,5,6,7,8,9 1,2,3,4,5,6,7,8,9 710 710 710 710 ISSUE FOR PERMIT BID & CONSTRUCTION NOTES: A. COOLING CAPACITY BASED ON EAT 80DEG FDB/67 DEG. FWB INDOOR ENTERING AIR TEMPERATURE AND 95 DEG. FWB. B. REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL CHARACTERISTICS. HEATER SHALL BE CAPABLE OF SCHEDULED HEATING CAPACITY AT VOLTAGE SHOWN ON ELECTRICAL DRAWINGS. NOTES: ACCESSORIES: A. COOLING CAPACITY BASED ON EAT 80DEG FDB/67 DEG. FWB INDOOR ENTERING AIR TEMPERATURE AND 95 DEG. FWB. B. COOLING ONLY 1. INDOOR UNIT - SINGLE POINT POWER WIRING KIT WITH DISCONNECTING MEANS AND OVERLOAD PROTECTION 2. OUTDOOR UNIT - DISCONNECT PROVIDED BY ELECTRICAL 3. FACTORY MOUNTED THERMAL EXPANSION VALVE TO ACHIEVE 14 SEER RATING (IF REQUIRED) 4. REFRIGERANT FILTER DRIER (LOCATE PER MANUFACTURERS RECOMMENDATION) 5. SAF-T-SWITCH INSTALLED IN SECONDARY CONDENSATE DRAIN FOR OVERFLOW PROTECTION. 6. MINIMUM MERV 7 REMOVABLE FILTER. 7. 7-DAY PROGRAMMABLE THERMOSTAT WITH FAN-ON-AUTO CONTROL AND AUTO HEATING/COOLING CHANGEOVER. 8. LOCKING THERMOSTAT COVER. 9. COMPRESSOR ANTI-RECYCLE CONTROLS. ACCESSORIES: 1. LOW AMBIENT OPERATION KIT. 2. WASHABLE FILTER. 3. SINGLE POWER POINT OF CONNECTION. 4. EQUIPMENT MANUFACTURER PROVIDED CONDENSATE PUMP. SELECTIONS BASED ON PRODUCTS BY TRANE EQUAL PRODUCTS BY CARRIER, YORK, LENNOX. SELECTIONS BASED ON PRODUCTS BY DAIKIN EQUAL PRODUCTS BY LG, MITSUBISHI, TOSHIBA. FANS GRILLES,REGISTERSANDDIFFUSERS TAG MODEL DUTY CFM ESP (IN.WG.) MOTORHP RPM DRIVE WEIGHT (LBS) ACCESSORIES EF 1 EF 2 EF 3 EF 4 EF 5 EF 6 EF 7 G-103-VG G-095-VG G-095-VG G-090-VG G-090-VG G-090-VG SP-110-VG EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST 1200 750 800 450 525 675 100 0.375 0.375 0.375 0.375 0.375 0.375 0.25 1/4 1/6 1/6 1/10 1/10 1/6 8.4 W 1725 1725 1725 1725 1725 1725 940 DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT DIRECT 40 30 30 30 30 30 15 1,2,3,4,5 1,2,3,4,5 1,2,3,4,5 1,2,3,4,5 1,2,3,4,5 1,2,3,4,5 1,2,3,5 SERIES TAG A B C D E F G H TMS TMS 50F 50F 300FL 350FL TBDI 50FF CFM SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS DUTY SUPPLY SUPPLY RETURN EXHAUST SUPPLY RETURN / TXR SUPPLY RETURN NECKSIZE FACESIZE (IN) DAMPER MATERIAL NOTES/ ACCESSORIES SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS SEE DWGS 24x24 12x12 24x24 12x12 SEE DWGS SEE DWGS SEE DWGS 24x24 YES YES NO NO NO NO NO NO STEEL ALUMINUM ALUMNIUM ALUMINUM ALUMINUM ALUMINUM STEEL ALUMINUM ACCESSORIES 1,2 ACCESSORIES 1,2 NOTE E - 1991 FM 158, BRYAN, TX 77845 TAG SPLITSYSTEMHEATPUMP CENTRAL BAPTIST CHURCH CHILDRENS BUILDING DUCTLESSSPLITSYSTEM(COOLINGONLY) ACCESSORIES: NOTES (APPLY TO ALL DEVICES UNO): 1. MOTORIZED BACKDRAFT DAMPER 2. SPEED CONTROLLER 3. DISCONNECT SWITCH 4. 12" HIGH INSULATED ROOF CURB 5. BIRD SCREEN A. REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF CEILING AND/ OR SUSPENSION SYSTEM. B. FINISH SHALL BE OF THE TYPE AND COLOR SELECTED BY THE ARCHITECT. SUBMIT CHART FOR SHOP DRAWINGS. C. FOR DRYWALL OR PLASTER CEILING INSTALLATION, PROVIDE PLASTER FRAME. D. WHEN A DAMPER IS CALLED FOR ABOVE AND THE DEVICE IS TO BE MOUNTED IN AN INACCESSIBLE CEILING, EITHER A FACE ADJUSTABLE OR REMOTE OPERATED BALANCING DAMPER SHALL BE INCLUDED. E. TWO 1" SLOTS, 4' LONG, FACTORY INSULATED PLENUM. SELECTIONS ARE BASED ON PRODUCTS BY: GREENHECK EQUAL PRODUCTS: PENN, CARNES, COOK ACCESSORIES: 1. MOLDED INSULATION (R-6) BLANKET ON BACK PAN. 2. BALANCING DAMPER IN INLET. SELECTIONS ARE BASED ON PRODUCTS BY: TITUS. EQUAL PRODUCTS: KRUEGER, CARNES, ANEMOSTAT, TUTTLE& BAILEY, PRICE, J & J, METAL AIRE. WALLLOUVERS SIZE(IN) TAG MODELNO. WL 1 WL 2 ELECTRICHEATERS MINFREE AREA (SQ.FT.) CFM MAXPRESS. DROP (IN.WG.) WIDTH HEIGHT ESD-603 12 16 0.44 100 0.15 ESD-603 12 16 0.44 120 0.1 NOTES: A. FINAL COLOR SELECTION SHALL BE MADE BY ARCHITECT AT TIME OF SHOP DRAWINGS APPROVAL. ACCESSORIES: 1. MOTOR OPERATED DAMPER 2. BAKED ON ENAMEL FINISH. 3. BIRD SCREEN SELECTIONS ARE BASED ON GREENHECK EQUAL PRODUCTS: CARNES, RUSKIN, ARROW OPERATOR INTERLOCK FRAME ACCESSORIES MOTORIZED DAMPER MOTORIZED DAMPER EF-7 ALUMINUM 1,2,3 AH-3 ALUMINUM 1,2,3 TAG MODELNO EH 1 AFA840D APPLICATION MOUNTING FREEZE PROTECTION 24" AFF K.W. WEIGHT (LBS) ACCESSORIES 4 30 1,2,3 NOTES: A. ALL HEATERS SHALL BE UL LISTED. B. CAPACITY SCHEDULED IS AT INSTALLED VOLTAGE. COORDINATE WITH ELECTRICAL DRAWINGS. C. ALL HEATERS SHALL HAVE THERMAL OVERLOAD PROTECTION. D. SPRINKLER RISER ROOM HEATER - THERMOSTAT SETPOINT SHALL BE 45 DEGREES FARENHEIGHT ACCESSORIES: 1. INTEGRAL TAMPERPROOF THERMOSTAT. 2. INTEGRAL DISCONNECT SWITCH. 3. SURFACE MOUNTING KIT. No. Date Revision RAC Drawn SELECTIONS ARE BASED ON PRODUCTS BY: RAYWALL EQUAL PRODUCTS: MARKEL, BERKO, INDEECO JRM Checked WAS Approved SCHEDULES MECHANICAL Project No. Date Last Revision 15187.00 05/11/2016 M-102 printed5/11/2016 12:26:06 PM WING NUT NYLON ZIP TIES H UNION ROOFTOP UNIT INTERIOR LINER H = FAN INLET PRESSURE (IN. WC) + 1" CL H/2 MINIMUM ROUND SHEET METAL DUCT DIAMETER AS INDICATED ON PLANS PRE-INSULATED FLEXIBLE DUCTWORK. SEE GENERAL NOTES/SPECIFICATIONS. LENGTH SHALL NOT EXCEED 8'-0". PROVIDE SUPPORT PER SMACNA STANDARDS AND INSTALL FREE OF KINKS & SAGS. ROOF CURB FINISHED ROOF THERMAFLEX FLEXFLOW ELBOW SUPPORT SUPPORT PIPING 6' OC WITH MIFAB MODEL C PIPE SUPPORT ON ROOFING WALKPAD MATERIAL - SECURE PIPE WITH PIPE CLAMP CONICAL SPIN-IN FITTING WITH MVD VOLUME DAMPER NOT TO SCALE CONDENSING UNIT OR HEAT PUMP 1/4" x 1-1/2" CADMIUMPLATED LAG SCREWS INSULATED REFRIGERANT LINE SET, TYPICAL 2"X2", 3/8 " THICK NEOPRENE PAD, TYPICAL OF 4 ROOF INSULATION DIRECTION OF GRAIN ROOF DECK 2"R 45° MIN. 26 GAUGE VANES B 1/8" MALLEABLE GALVANIZED STEEL WIRE ROPE CLIP 1 INCH WIDE, MINIMUM 22 GAUGE SHEET METAL HANGER STRAP AT 10'-0" OC (MIN.) 45° THIMBLE FILTER SECTION WITH SIDE ACCESS - MAINTAIN CLEAR SPACE FOR FILTER REMOVAL OUTDOOR AIR INTAKE HOOD FLEX CONNECTION, TYP. 14" HIGH (MIN.) ROOF CURB LINED SUPPLY AIR DUCT (OR DUCTBOARD IF SPECIFIED) OA INTAKE PER PLANS ROOF DECK 2x4 WOOD NAILER. CAULK BETWEEN NAILER AND ROOF CURB CONTINUOUS 1_2 " x 1" RUBBER GASKET GALVANIZED FLASHING CONTINUOUS OVER WOOD NAILER ROOF MOUNTED EXHAUST FAN (RE: SCHEDULE) INTERNAL DISCONNECT SWITCH DRYER EXHAUST DUCT ROUTED TO WALL CAP. SEE PLANS FOR DUCT SIZE AND ROUTING. BIRD SCREEN ELECTRIC CONDUIT GUIDE NOTES: 1. PROVIDE WITH INTEGRAL BACKDRAFT DAMPER 2. WALL CAP BY VENTCRAFT, OR APPROVED EQUAL. 3. PROVIDE CAP WITH PAINT GRIP COATING FOR FIELD PAINTING. 4. PROVIDE INSECT SCREEN FOR BATHROOM EXHAUST WALL CAP ONLY. WELDED PREFABRICATED INSULATED AIR TIGHT ROOF CURB C c P ma u N b o M E J 3 0 6 O -P e lb k S & n rd o E H :A n IL U R Y N iT .g ,Ic rs e D O IG E @ e ,s V R j H N T 4 ) 0 7 ( m l.c k s n a rd o O N j 5 R 7 4 C2 1 0 X A R F O J O 8 4 ) 0 7 ( S , R D 6 2 A G 0 A N 1 &S 7 0 3 K A G N N E L I E R S IN C . P 3 0 6 CU M E c m u N b Jo H O :P IL a A kl N S & n d o r-E e b D Y IT O R n i R rs,c.g e ,N E IV js G N @ e O 4 ) 0 7 ( T H m l.c k s n a rd o j R C 7 R 4 5 O X A F 1 S 0 2 ,( 8 4 ) 0 7 O G J A 6 2 R 0 D 0 1 7 3 N &S A K A G IN E N E L R S N I C . 4" M CO2 CONDENSATE DRAIN- TRAP PER DETAIL; SIZE AND ROUTE PER PLANS NOTES: 1. WHEN FACTORY MOUNTED DISCONNECT SWITCH IS SCHEDULED OR SPECIFIED, CONDUIT FROM BELOW THE ROOF SHALL BE LOCATED INSIDE THE ROOF CURB. FIELD MOUNTED DISCONNECT SWITCH, BRACKETS, AND CONDUIT SHALL BE LOCATED SUCH THAT THEY ARE CLEAR OF ALL UNIT ACCESS PANELS AND DO NOT OBSTRUCT AIRFLOW. ATTACH DISCONNECT SWITCH SUPPORT BRACKETS TO STRUCTURAL MEMBERS OF UNIT AND NOT DIRECTLY TO SHEETMETAL CASING (COORDINATE WITH ELECTRICIAN). 2. DO NOT MOUNT DISCONNECT SWITCH OVER NAMEPLATE OF UNIT (COORDINATE WITH ELECTRICIAN). 3. CUT OPENINGS IN THE ROOF DECK ONLY FOR SUPPLY AND RETURN DUCT PENETRATIONS PER MANUFACTURER'S DIMENSIONAL LAYOUT DRAWINGS. BATT INSULATION SHALL COVER THE ENTIRE AREA OUTLINED BY THE CURB AND IN BETWEEN SUPPLY AND RETURN DUCTS. 4. MAINTAIN 10 LINEAL FEET BETWEEN OA INTAKE HOOD AND EXHAUST FANS, PLUMBING VENTS, ETC. ROOF TOP UNIT DETAIL NOT TO SCALE RA SA CO2 SENSOR. PROVIDE AS NOTED. EXPOSED SPIRAL DUCT HANGER DETAIL NOT TO SCALE SECURE TO CURB WITH STAINLESS STEEL SCREWS 8" O.C. ALL SIDES PRIMARY CONDENSATE DRAIN- FULL SIZE OF UNIT CONNECTION (3/4" MIN.) UNLESS NOTED OTHERWISE. SLOPE 1/8"/FT. (OR SLOPE PER LOCAL CODE) MIN. REFER TO FLOOR PLANS FOR ROUTING DRAIN PAN GALVANIZED FLASHING. EXTEND 6" (MIN.) AND SEAL WEATHERTIGHT 14" MIN ABOVE ROOF FINISHED SURFACE. COORDINATE CURB HEIGHT WITH INSULATION THICKNESS TO ACHIEVE THIS DIMENSION ROOF CURB INSULATION ROOF MEMBRANE. RE: ARCH DRYER EXHAUST WALL CAP NOT TO SCALE CONDENSATE TRAP PER DETAIL OR INSTALL PER MANUFACTURER'S RECOMMENDATIONS CONDENSATE OVERFLOW SWITCH IN SECONDARY DRAIN; "SAFE-T-SWITCH" OR EQUAL. INTERLOCK WITH AH TO SHUT UNIT OFF IF LIQUID IS DETECTED LINED RETURN AIR PLENUM/DUCTWORK (OR DUCTBOARD IF SPECIFIED) NOTES: 1. STRUCTURE VARIES. COORDINATE WITH STRUCTURAL DOCUMENTS FOR PROPER ANCHORING METHOD (BEAM CLAMPS, EXPANSION BOLTS, INSERTS, ETC.). 2. ON SERVICE SIDE OF UNIT, MAINTAIN A 42"W X LENGTH OF UNIT CLEARANCE TO PIPING, DUCTWORK, EQUIPMENT, CONDUIT, ETC. ELECTRIC HEAT SECTIONS OR DUCT HEATERS: MAINTAIN A MIN. OF 42" CLEARANCE (OR PER N.E.C.) IN FRONT OF ALL ELECTRIC HEATER CONTROL PANELS. THE WIDTH OF THE SERVICE CLEARANCE SHALL BE 30" OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER. FOR LOW VOLTAGE CONTROL PANELS (WITHOUT ELECTRIC HEATER), MAINTAIN A MIN. OF 24" CLEARANCE (OR PER N.E.C.) IN FRONT OF PANEL. THE WIDTH OF THE SERVICE CLEARANCE SHALL BE 24" OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER. NO PIPES, SPRINKLERS, CONDUITS, ETC. SHALL BE INSTALLED WITHIN THIS ZONE. COORDINATE AND PLAN WORK CAREFULLY WITH ALL OTHER TRADES. 3. WHERE AHs OR THEIR WORKING CLEARANCE ARE LOCATED ABOVE LIGHT FIXTURES, THE FIXTURE SHALL HAVE A FLEXIBLE WHIP TO ALLOW TEMPORARY RELOCATION OF THE FIXTURE FOR ACCESS TO THE AH. COORDINATE WITH ELECTRICAL CONTRACTOR. 4. PROVIDE MINIMUM SERVICE CLEARANCES AS RECOMMENDED BY UNIT MANUFACTURER. SUSPENDED HORIZONTAL AIR HANDLING UNIT DETAIL NOT TO SCALE ISSUE FOR PERMIT BID & CONSTRUCTION SPIRAL DUCTWORK - ALL EXPOSED SHEETMETAL SURFACES (SA & RA) AND HANGAR STRAPS SHALL HAVE A "PAINT GRIP" FINISH FOR FIELD PAINTING. AS AN OPTION, MILL PHOSPHATIZED STEEL DUCTWORK MAY BE USED. INTERNALLY INSULATE PER HVAC GENERAL NOTES OR SPEC SECTION 23 07 00 UNO. NOTES: 1. PAINT COLOR SHALL BE SELECTED BY ARCHITECT. 2. PAINTING BY OTHERS. COORDINATE WITH ARCHITECTURAL DWGS. TURNING VANE DETAILS NOT TO SCALE THREADED ROD WITH SPRING TYPE VIBRATION ISOLATORS (SIZE RODS AND SUPPORT UNIT AS RECOMMENDED BY MANUFACTURER) (TYPICAL OF FOUR ONE PER CORNER). SEE NOTE 1 SMALL NOTE: TURNING VANES SHALL BE CONSTRUCTED PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS (2005 EDITION FIGURE 4-3). ROOF CURB FRAMING MECHANICAL EQUIPMENT FLEXIBLE DUCT CONNECTOR, TYP. THERMOSTAT WIRING DUCT SMOKE DETECTOR PER CODE LARGE STEEL JOIST NOT TO SCALE BOLT AND NUT TYPE 2 RUNNER WELD EVERY SIXTH VANE TO RUNNER (OVER 1500 FPM) 2-1/4" BURGLAR BARS, IF SPECIFIED A MINIMUM 1/8" 7x19 STRANDED GALVANIZED AIRCRAFT CABLE 45° STEEL ANGLES, ALL SIDES OF ROOF OPENING - SEE STRUCTURAL DWGS. c NOT TO SCALE KEY PLAN MIN. 24 GAUGE VANES STEEL DECK PIPING SUPPORT (CONDENSATE) KINETICS NOISE CONTROL "KIP-R1" FIBERGLASS PAD CONTINUOUS BETWEEN RTU AND CURB PER MANUFACTURER'S RECOMMENDATIONS POWER WIRING (SEE ELECTRICAL DWGS.) 3-1/4" 45° NOT TO SCALE LINE INSIDE OF CURB AND ROOF DECK WITH KINETICS KNM-100C ACOUSTICAL BARRIER SUSPEND FROM STRUCTURE ABOVE TURNBUCKLE 4-1/2"R OUTDOOR UNIT ROOF MOUNTING DETAIL FELTED SEMI-RIGID MINERAL WOOL BATT INSULATION, 4 LB. DENSITY, 8" THICK TOTAL NOTE: DETAIL SHOWN APPLIES TO 18" MAXIMUM DUCT SIZE. FOR LARGER SIZES REFER TO SMACNA HVAC DUCT CONSTRUCTION STANDARDS. 2-1/8" CANT ROOF INSULATION 1'-2" MINIMUM 1. PLACE BASE SHEETS ON ROOFING BEFORE GRAVEL, IF ANY. SET BLOCKS FREE ON BASE SHEETS. STACK BLOCKS AND NAIL THEM TOGETHER WHERE REQUIRED TO ELEVATE PIPING. 2. SUPPORTS SHALL BE PLACED EVERY 6' ON CENTER (BASED ON SCHEDULE 40 PVC). NOTES: 1. MIFAB PIPE SUPPORT TO HAVE 14 GA. X 3/16 " WIDE GALVANIZED CHANNEL. LENGTH TO SUIT QUANTITY OF PIPING SUPPORTED. PROVIDE INSULATION SHIELD WHERE STRUT CLAMP COMES IN CONTACT WITH INSULATION. 2. EQUIPMENT SUPPORTS WITH THE FEWEST ROOF PENETRATIONS ARE PREFERRED HOWEVER, ALTERNATE SYSTEMS BY MIRO OR CADDY PYRAMID ARE ACCEPTABLE PROVIDED THEY ARE INSTALLED IN A PERMANENT MANNER AND SECURED TO THE ROOF STRUCTURE. DISCONNECT SWITCH (SEE ELECTRICAL DWGS. UNLESS FACTORY MOUNTED) 1-1/8" 2-1/4" NOTES: SOLID PLATFORM TYPE EQUIPMENT CURB BY ROOF PRODUCTS AND SUPPORTS, INC.- SECURE TO ROOF STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS CONDENSER FAN DISCHARGE NOT TO SCALE 1-1/8" SEAL OPENING AIR AND WATER TIGHT WITH EXPANDING FOAM INSULATION ROOF STRUCTURE ROOFING PROVIDE MULTIPLE BASE SHEETS OR TRIM THE TIMBER AS REQUIRED TO ACCOMMODATE VARIATIONS IN ROOF ELEVATION. NOT TO SCALE c PROVIDE FLASHING AND COUNTERFLASHING AT ROOFTOP UNIT BASE RAIL INTEGRAL 2X WOOD NAILER ROOF CURB BY ROOFTOP UNIT MANUFACTURER SUPPORT PIPING 6' OC WITH MIFAB MODEL C PIPE SUPPORT ON ROOFING WALKPAD MATERIAL SECURE PIPE WITH PIPE CLAMP 18" x 18" x 1/2" THICK ROOF WALKWAY MATERIAL FOR BASE SHEET. ("CAREY-TRED" OR PER ARCHITECTURAL SPECIFICATIONS.) SPIRAL DUCT THRU WALL DETAIL 3/4" x1/4" WIDE GASKET AROUND ENTIRE CURB FRAME 3/4" NOTES: 1. WHEN SPECIFIED TO BE PAINTED, ALL EXPOSED SHEETMETAL SURFACES INCLUDING HANGER STRAPS SHALL HAVE A "PAINT GRIP" FINISH FOR FIELD PAINTING. AS AN OPTION, MILL PHOSPHATIZED STEEL DUCTWORK MAY BE USED. 2. PAINT COLOR SHALL BE SELECTED BY ARCHITECT. 3. PAINTING BY OTHERS. COORDINATE WITH ARCHITECTURAL DWGS. 4. SECURE ESCUTCHEON TO DUCT WITH SHEETMETAL SCREWS AT 6" OC. SPIRAL DUCT SUPPLY REGISTER DETAIL ROOFTOP UNIT SHALL BE LEVEL AND SHALL NOT SIT ON METAL DECK, BUT ON STEEL ANGLES. ROOF TOP UNIT GALVANIZED STEEL PIPE CLAMP. DO NOT CLAMP PIPE TIGHT. c NOTES: 1. PAINT COLOR SHALL BE SELECTED BY ARCHITECT. 2. PAINTING BY OTHERS. COORDINATE WITH ARCHITECTURAL DWGS. NOT TO SCALE WATERTIGHT REFRIGERANT LINE SET CHASE SUPPORT RS & RL 6' OC WITH MIFAB MODEL C PIPE SUPPORT ON ROOFING WALKPAD MATERIAL - SECURE PIPE WITH PIPE CLAMP SA DUCTWORK - INTERNALLY LINED; RA DUCTWORK - NO INSULATION; OA DUCTWORK - EXTERNALLY INSULATED; REFER TO HVAC GENERAL NOTES OR SPEC SECTION 23 07 00 UNO. TURN DOWN 30 DEGREES NOT TO SCALE SECURE OUTDOOR UNIT TO CURB PER MANUFACTURER'S RECOMMENDATIONS, TYP. 4 LOCATIONS. SEAL SCREW HOLES WITH 20-YR SILICONE SEALANT CONCEALED AREA (DUCT ROUTED ABOVE CEILING) FOLD SHEET METAL ENDS DOWN 1" COMMERCIAL FLEXIBLE DUCT TAKE-OFF DETAIL CONDENSATE DRAIN TRAP DETAIL ARM 20 GAUGE SHEETMETAL ESCUTCHEON PLATE (TO COVER ENTIRE OPENING) FOR A CLEAN AND NEAT APPEARANCE FILL ANNULAR SPACE WITH MINERAL WOOL SUPPLY DIFFUSER OR REGISTER CEILING - SEE ARCH. DWGS. FOR TYPE WALL SUPPLY DUCTWORK (CONCEALED) EXPOSED AREA (DUCT ROUTED IN SPACE) SUPPLY REGISTER BRANCH DUCT NOTES: 1. SLOPE PIPING DOWN TOWARDS PLUMBING DRAIN AT 1/8 " PER FOOT. 2. RUNNING TRAPS ARE NOT ALLOWED. 3. TEST THE FLOAT SWITCH IN THE DRAIN PAN FOR PROPER OPERATION AT LEAST ONCE A YEAR. VOLUME DAMPER SHAFT RAISED PANEL 1/ " PLATE FOR DUCTS UP TO 18" 16 1/ " PLATE FOR DUCTS 19" AND UP 8 SPIRAL SUPPLY DUCTWORK ALL EXPOSED SHEETMETAL SURFACES (SA & RA) AND HANGAR STRAPS SHALL HAVE A "PAINT GRIP" FINISH FOR FIELD PAINTING. AS AN OPTION, MILL PHOSPHATIZED STEEL DUCTWORK MAY BE USED. INTERNALLY INSULATE PER HVAC GENERAL NOTES OR SPEC SECTION 23 07 00 UNO. MECHANICAL FASTENER INSULATION PROVIDE SPACE FOR ELECTRICAL CONDUIT BETWEEN DAMPER AND ROOF OPENING 1991 FM 158, BRYAN, TX 77845 QUADRANT 3/ " FOR DUCTS UP TO 18" 8 1/ " FOR DUCTS 19" THRU 48" 2 CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON ZIP TIES. APPLY A BEAD OF MASTIC BETWEEN THE INTERIOR LINER AND THE SHEETMETAL PRIOR TO ZIP-TYING. THE INTERIOR LINER AND EXTERIOR INSULATION OF THE FLEX DUCT SHALL BE ZIP-TIED INDIVIDUALLY. INSTALL ZIP TIES USING A TENSIONING TOOL PER MANUFACTURER'S RECOMMENDATIONS 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 FACTORY DRAIN PAN SUSPEND FROM STRUCTURE - REFER TO EXPOSED SPIRAL DUCT HANGER DETAIL CENTRAL BAPTIST CHURCH CHILDRENS BUILDING TRAP AND PIPE SAME SIZE AS UNIT CONNECTION - ROUTE TO NEAREST PLUMBING DRAIN SEE PLANS FOR CONTINUATION HAND TIGHT PLUGS FOR CLEANOUT PURPOSES 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 FLOAT SWITCH WIRED TO SHUT DOWN RTU; SAF-T-SWITCH MODEL SS3 SCREWS DUCT INSULATION ROOF TOP UNIT ROOF DECK, RE: STRUCT. BACKDRAFT DAMPER (SEE NOTE 3) FLEX. CONNECTOR LINE INSIDE OF CURB AND ROOF DECK WITH KINETICS KNM-100C ACOUSTICAL BARRIER ROOF CURB CAULK TO FILL GAP CONTINUOUS BENT DUCT FLANGE ROOF CURB ROOF EXHAUST DUCT SIZE AS SHOWN ON PLANS. DUCT SHALL EXTEND UP TO ROOF EXHAUSTER OPENING. DUCT SHALL NOT TERMINATE BELOW ROOF. RADIUS ELBOW (WHERE REQUIRED FOR DUCT OFFSET) COVER OPENING WITH 1/2''x1/2" HARDWARE CLOTH, 0.135'' WIRE NOTES: 1. SEAL PENETRATION AIR TIGHT AROUND CONDUIT THRU WELDED ROOF CURB. 2. SEAL AIR TIGHT ANY PENETRATIONS THROUGH WELDED ROOF CURB. 3. WITH THE EXCEPTION OF KITCHEN GREASE EXHAUST FANS, PROVIDE MOTORIZED DAMPER FOR ALL EXHAUST FANS WITH CAPACITY 300 CFM AND GREATER. ROOF MOUNTED EXHAUST FAN NOT TO SCALE ROOF DECK RADIUS ELBOWS SHALL BE USED ON ALL SUPPLY DUCT TURNS WHEN POSSIBLE. IF RADIUS ELBOWS CANNOT BE USED, MITERED ELBOWS WITH TURNING VANES MAY BE SUBSTITUTED. No. Date Revision RAC Drawn SMOKE DETECTOR. PROVIDE AS NOTED. (TYP.) ROOF TOP UNIT MOUNTING DETAIL JRM Checked WAS Approved NOT TO SCALE DETAILS MECHANICAL Project No. Date Last Revision 15187.00 05/11/2016 M-103 printed5/11/2016 12:26:10 PM RTU SEQUENCE OF OPERATION 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 RECTANGULAR SUPPLY, RETURN OR EXHAUST DUCT RECTANGULAR SUPPLY, RETURN OR EXHAUST DUCT RECTANGULAR BRANCH DUCT TAKE-OFF LOW PRESSURE BRANCH DUCT TAKE-OFF (RECTANGULAR 45° ENTRY) LOW PRESSURE BRANCH DUCT TAKE-OFF (ROUND BRANCH ENTRY) NOT TO SCALE NOT TO SCALE SA AIRFLOW SA AIRFLOW e. Morning Warm-Up Mode: During optimal start, if the space temperature is below the occupied heating setpoint a morning warm-up mode shall be activated. When morning warm-up is initiated the unit shall enable the heating and supply fan. The outside air damper shall remain closed. When the space temperature reaches the occupied heating setpoint (adj.), the unit shall transition to the occupied mode. f. Pre-Cool Mode: During optimal start, if the space temperature is above the occupied cooling setpoint, pre-cool mode shall be activated. When pre-cool is initiated the unit shall enable the fan and cooling or economizer. The outside air damper shall remain closed, unless economizing. When the space temperature reaches occupied cooling setpoint (adj.), the unit shall transition to the occupied mode. RA & EA AIRFLOW g. Optimal Stop: The BAS shall monitor the scheduled unoccupied time, occupied setpoints and space temperature to calculate when the optimal stop occurs. When the optimal stop mode is active the unit controller shall maintain the space temperature to the space temperature offset setpoint. RA & EA AIRFLOW SHOP FABRICATED 90° CONICAL FITTING h. Occupied Bypass: The BAS shall monitor the status of the “on” and “cancel” buttons of the space temperature sensor. When an occupied bypass request is received from a space sensor, the unit shall transition from its current occupancy mode to occupied bypass mode and the unit shall maintain the space temperature to the occupied setpoints (adj.). i. Cooling Mode: The unit controller shall use space temperature and space temperature setpoint to determine when to initiate requests for cooling. When the space temperature rises above the setpoint, the unit controller shall modulate the economizer or stage the DX cooling as required to maintain the space temperature setpoint. The first compressor shall energize after its minimum 3-minute off time has expired. If additional cooling capacity is required the second stage of cooling shall be enabled. Once the space temperature falls below the setpoint the compressors shall be deactivated and the economizer shall return to minimum position. SHOP FABRICATED 45° CONICAL FITTING NOTE: 1. ACCEPTABLE ALTERNATES ARE CONICAL TAPS AND CONICAL SADDLE TAPS PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS. j. Heating Mode: The unit controller shall use the space temperature and space temperature setpoint to determine when to initiate requests for heat. When the space temperature drops below the setpoint, the unit controller shall enable electric heating stages to maintain the space temperature setpoint. Once the space temperature rises above the setpoint the electric heating stages shall be disabled. k. Dehumidification: Factory installed hot gas reheat shall allow application of dehumidification. Dehumidification shall be allowed only when the outside air temperature is above 40.0 deg. F and below 100.0 deg. F. The economizer outside air damper shall drive to minimum position during dehumidification. 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 CONICAL TAP (SPIN-IN OR FLANGED) L = 1/4W, 4" MIN. d. Optimal Start: The BAS shall monitor the scheduled occupied time, occupied space setpoints and space temperature to calculate when the optimal start occurs. SA AIRFLOW ROUND BRANCH DUCT TAKE-OFF L c. Unoccupied Mode: When the space temperature is below the unoccupied heating setpoint of 60.0 deg. F (adj.) the supply fan shall start, the outside air damper shall remain closed and the electric heat shall be enabled. When the space temperature rises above the unoccupied heating setpoint of 60.0 deg. F (adj.) plus the unoccupied differential of 4.0 deg. F (adj.) the supply fan shall stop and the electric heat shall be disabled. When the space temperature is above the unoccupied cooling setpoint of 85.0 deg. F (adj.) the supply fan shall start, the outside air damper shall open if economizing is enabled and remain closed if economizing is disabled and the DX cooling shall be enabled. When the space temperature falls below the unoccupied cooling setpoint of 85.0 deg. F (adj.) minus the unoccupied differential of 4.0 deg. F (adj.) the supply fan shall stop, the DX cooling shall be disabled and the outside air damper shall close. RA & EA AIRFLOW b. Occupied Mode: During occupied periods, the supply fan shall run continuously and the outside air damper shall open to maintain minimum ventilation requirements. The DX cooling and electric heat shall stage to maintain the occupied space temperature setpoint. If economizing is enabled the outside air damper shall modulate to maintain the occupied space temperature setpoint. MVD RA & EA AIRFLOW W a. Building Automation System Interface: The Building Automation System (BAS) shall send the controller Occupied Bypass, Morning Warm-up / Pre-Cool, Occupied / Unoccupied and Heat / Cool modes. If a BAS is not present, or communication is lost with the BAS the controller shall operate using default modes and setpoints. SA AIRFLOW MVD NOTE: 1. ACCEPTABLE ALTERNATES ARE CONICAL TAPS AND CONICAL SADDLE TAPS PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS. LOW PRESSURE BRANCH DUCT TAKE-OFF (ALTERNATIVE ROUND 90° BRANCH) LOW PRESSURE BRANCH DUCT TAKE-OFF (ALTERNATIVE ROUND 45° BRANCH) NOT TO SCALE NOT TO SCALE KEY PLAN A B l. Single compressor units: On a call for dehumidification, the reheat valve shall energize and the compressor shall enable. When the humidity control setpoint is satisfied, the valve shall be de-energized and the compressor shall be disabled. If there is a call for cooling from the space temperature controller, while in reheat, the reheat valve shall be de-energized and the compressor continues to run. ISSUE FOR PERMIT BID & CONSTRUCTION 2W WALL - SEE ARCH. DWGS. FOR TYPE DOUBLE THICKNESS TURNING VANES n. Economizer: The mixed air sensor shall measures the dry bulb temperature of the air leaving the evaporator coil while economizing. When economizing is enabled and the unit is operating in the cooling mode, the economizer damper shall be modulated between its minimum position and 100% to maintain the space temperature setpoint. The economizer damper shall modulate toward minimum position in the event the mixed air temperature falls below the low limit temperature setting. Compressors shall be delayed from operating until the economizer has opened to 100%. MVD STEEL LINTEL, IF REQUIRED - SEE STRUCT./ARCH. DWGS. MVD W HEAD FLASHING W o. Reference Dry Bulb: Outside air (OA) temperature shall compared with a reference dry bulb setpoint. The economizer shall enable when the OA temperature is less than reference dry bulb setpoint. The economizer shall be disabled when OA temperature is greater than reference dry bulb setpoint + 5.0 deg. F. ALUMINUM ANGLE AROUND PERIMETER SECURE TO WALL & LOUVER LOUVER p. Supply Fan: The supply fan shall be enabled while in the occupied mode and cycled on during the unoccupied mode. A differential pressure switch shall monitor the differential pressure across the fan. If the switch does not open within 40 seconds after a request for fan operation a fan failure alarm shall be annunciated at the BAS, the unit shall stop, requiring a manual reset. SUPPLY, RETURN OR EXHAUST DUCT 2W BIRD SCREEN q. Building Pressure Control: The power exhaust shall enable when the economizer damper position is equal to or greater than the exhaust fan setpoint. 90° r. Filter Status: A differential pressure switch shall monitor the differential pressure across the filter when the fan is running. If the switch closes for 2 minutes after a request for fan operation a dirty filter alarm shall be annunciated at the BAS. SEAL AROUND ENTIRE PERIMETER TO MAKE WATERTIGHT CENTERLINE RADIUS = 1.5 x 2W MVD MVD MOUNTING AND LINKAGE HARDWARE FOR ELECTRIC ACTUATOR (PROVIDE CONCEALED ACTUATOR/ LINKAGE IN SILL AS REQUIRED FOR FLUSH INTERIOR INSTALLATION) W W DRIP SILL AND FLASHING NOTE: ARCH. DWGS. AND MANUFACTURER'S INSTALLATION MANUAL SUPERCEDE THIS DWG. DIVIDED FLOW FITTING DETAILS WALL LOUVER DETAIL NOT TO SCALE NOT TO SCALE ROUTE DRYER EXHAUST DUCT TO EXTERIOR WALL IN THE MOST DIRECT MANNER POSSIBLE 2 RTU POINTS LIST 4" ROUND DRYER EXHAUST DUCT SHALL BE A MINIMUM OF 26 GAUGE 20 GAUGE GALVANIZED SHEET METAL HOOD - PAINT IN A COLOR SELECTED BY ARCHITECT. Scale: 1" = 1'-0" LINE INTERIOR OF SHEET METAL HOOD WITH DUCT LINER PROVIDE WATERPROOF SEALANT BETWEEN SLEEVES AND PIPES 16 GAUGE (MIN.) EQUIPMENT CURB SLOPE PIPING AWAY FROM HOOD 1991 FM 158, BRYAN, TX 77845 SUPPLY, RETURN OR EXHAUST DUCT CENTRAL BAPTIST CHURCH CHILDRENS BUILDING m. Dual compressor units: On a call for dehumidification, the reheat valve shall energize and both compressors shall enable. When the humidity control setpoint is satisfied, the valve shall be de-energized and both compressors shall be disabled. If there is a call for 1st stage cooling while in the dehumidification mode, no action shall take place. If there is a call for 2nd stage cooling, the reheat valve shall be de-energized, and the unit shall revert to the cooling mode. If 2nd stage cooling is satisfied and there is still a call for dehumidification, the reheat valve shall once again be energized. EXTEND 4" DRYER EXHAUST DUCT THRU DRYER EXHAUST BOX TO ALLOW CONNECTION FOR FLEXIBLE DRYER HOSE METAL FLANGE SECURE EXHAUST BOX TO WALL PER MANUFACTURER'S RECOMMENDATIONS FLEXIBLE DRYER HOSE BY INSTALLER DRYER EXHAUST WALL BOX REFER TO PLANS FOR EXACT LOCATION AND SEE NOTES BELOW FOR ADDITIONAL INFORMATION ROOF DECK 1-1/4"x1-1/4"x1/4" ANGLE FRAMING ROOFING CONTRACTOR TO INSTALL ROOF CURB. MECH. CONTRACTOR SHALL SUPERVISE THE INSTALLATION AND PAY ALL COSTS. SECURE PIPE TO WALL AND SUPPORT AT BASE 1-1/4"x 1-1/4"x 1/4" ANGLE FRAMING No. Date PIPE CURB DETAIL NOT TO SCALE NOTES: 1. DRYER EXHAUST BOX MODEL 425 AS MANUFACTURED BY IN-O-VATE TECHNOLOGIES; LISTED FOR 1-HR (F AND T RATINGS) WALL INSTALLATION; UL THROUGH-PENETRATION FIRESTOP SYSTEM NO. W-L-7129. USE FOR UPWARD EXHAUST DIRECTION AND DOWNWARD EXHAUST DIRECTION ONLY FOR PEDESTAL AND STACKING DRYERS. 2. FOR DOWNWARD EXHAUST DIRECTION USE THE MODEL 4D (EXCEPT FOR PEDESTAL AND STACKABLE DRYERS). 3. INSTALLATION REQUIRES THE SPACES BETWEEN THE SIDES OF THE BOX AND THE STUDS AND THE SPACE IMMEDIATELY ABOVE THE BOX TO BE TIGHTLY PACKED WITH GLASS FIBER BATT OR MINERAL WOOL BATT INSULATION. REFER TO UL INSTALLATION DETAILS FOR ADDITIONAL INFORMATION. 4. INSTALL 16 GA STEEL SHIELD PLATES AT THE FINISHED FACE OF FRAMING MEMBERS WHERE THERE IS LESS THAN 1 1/4 " BETWEEN THE DUCT AND THE FINISHED FACE OF THE FRAMING. SHIELD PLATES SHALL EXTEND 2" ABOVE SOLE PLATES AND 2" BELOW TOP PLATES. Revision RAC Drawn JRM Checked WAS Approved DRYER EXHAUST WALL BOX DETAIL NOT TO SCALE DETAILS MECHANICAL Project No. Date Last Revision 15187.00 05/11/2016 M-104 printed5/11/2016 12:26:14 PM KEYVALUE 1 2 3 4 5 6 7 1. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 36" IN FRONT OF ALL ELECTRICAL DISCONNECTS. 2. CONTRACTOR SHALL OBSERVE ALL MANUFACTURER CLEARANCE AND INSTALLATION GUIDELINES FOR MECHANICAL EQUIPMENT. 3. CONDENSATE FROM COOLING COILS SHALL BE COLLECTED PER LOCAL CITY REQUIREMENTS. 4. MATERIALS, EQUIPMENT OR LABOR NOT INDICATED BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE INSTALLATION SHALL BE PROVIDED. DRAWINGS AND SPECIFICATIONS DO NOT UNDERTAKE TO INDICATE EVERY ITEM OF MATERIAL, EQUIPMENT, OR LABOR REQUIRED TO PRODUCE A COMPLETE AND PROPERLY OPERATING INSTALLATION. 5. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT EXACT CONDITIONS. THE LOCATION OF EQUIPMENT, DUCTWORK, ETC. IS APPROXIMATE ONLY. THE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT TO BE SCALED. SCALES ARE SHOWN FOR REFERENCE AND APPROXIMATION ONLY. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONAL DATA OF BUILDING COMPONENTS. 6. INSTALL ALL DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE, IN ORDER TO MAXIMIZE CEILING HEIGHTS. 7. PROVIDE ALL OFFSETS AND TRANSITIONS IN DUCTWORK AS NEEDED TO MAINTAIN CEILING HEIGHTS AND TRANSITION OVER OR UNDER DUCTWORK AND OTHER BUILDING SYSTEMS, WHETHER SHOWN ON DRAWINGS OR NOT. 8. COORDINATE DUCTWORK WITH STRUCTURE, LIGHTING, SPRINKLERS, ETC. PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL MAKE EVERY EFFORT TO INSTALL DUCTWORK IN ORDER TO MINIMIZE DUCT TRANSITIONS, FITTINGS, AND ELBOWS AS MUCH AS POSSIBLE TO REDUCE SYSTEM STATIC PRESSURE. 10. ROUND AND RECTANGULAR ELBOWS SHALL BE IN STRICT CONFORMANCE OF THE SPECIFICATIONS. SEGMENTED ELBOWS ARE NOT ALLOWED. 11. CONVERGING AND DIVERGING AIRFLOWS SHALL BE PROVIDED WITH FITTINGS CONFORMING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE", LATEST EDITION, TO MINIMIZE SYSTEM PRESSURE DROP. 12. NOT ALL VOLUME CONTROL DAMPERS ARE INDICATED ON THE DRAWINGS. PROVIDE DAMPERS PER THE SPECIFICATIONS AND AS REQUIRED FOR BALANCING MAIN AND BRANCH TAKE-OFF AIRFLOWS TO THE DOWNSTREAM CFM SHOWN. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING COORDINATION DRAWINGS TO SCALE, AS REQUIRED, USING INPUT FROM ALL OTHER TRADES PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK. CONTRACTOR DRAWINGS SHALL INDICATE DUCT INSTALLATION IN CONGESTED SPACES, INDICATING COORDINATION WITH GENERAL CONSTRUCTION, BUILDING COMPONENTS, CEILING ELEVATIONS, AND OTHER BUILDING SERVICES. INDICATE PROPOSED CHANGES TO DUCT LAYOUT. 14. MOUNT THERMOSTATS AT 46" AFF AND 8" FROM THE EDGE OF THE WALL. COORDINATE LOCATIONS WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. 15. PROVIDE 1" DOOR UNDERCUT UNDER RESTROOM DOORS FOR MAKEUP AIR. 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 KEYNOTES(THISSHEET) GENERAL NOTES NOTE OFFSET, TRANSITION AND CONNECT SUPPLY AND RETURN DUCTWORK UP TO ROOFTOP UNIT. OFFSET, TRANSITION AND CONNECT EXHAUST DUCT UP TO FAN ON ROOF. REFER TO ARCHITECTURAL ELEVATIONS FOR AIR DEVICE LOCATIONS. REFER TO ARCHITECTURAL FOR LOUVER LOCATIONS. MAINTAIN 10' BETWEEN INTAKE AND EXHAUST. CONDENSATE DRAIN DOWN TO TAILPIECE. COORDINATE WITH PLUMBING FOR LOCATION. ROUTE RETURN DUCT BELOW SUPPLY AND TURN UP TO CONNECT GRILLES TO BOTTOM OF DUCT. ROUTE CONDENSATE TO HUB DRAIN ABOVE CEILING. TERMINATE 1" ABOVE DRAIN. REFER TO PLUMBING FOR EXACT LOCATION. ROUTE DUCT BELOW STRUCTURE. TURN UP AFTER STRUCTURE TO AVOID CONFLICTS WITH CEILING, LIGHTS, ETC. SLOPE DOWN AND ROUTE DUCT BELOW JOIST. TRANSITION TO ROUND DUCT AND TURN UP AFTER WALL PENETRATION. RETURN DUCT OPEN TO PLENUM. PROVIDE WIRE MESH SCREEN ON OPENING. ROUTE RETURN DUCTWORK BELOW SUPPLY DUCTWORK. OFFSET, TRANSITION AND CONNECT TO RETURN GRILLE. RETURN DUCT TURNED UP AFTER JOIST. 8 9 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 10 11 12 KEY PLAN B C C.1 D C.9 D.8 E E.6 F F.1 G G.1 G.2 G.7 H H.1 H.5 J J.8 K A B 235 A 10"ø 235 A 10"ø 235 A 10"ø 24x20 SA 12x14 SA A 260 10"ø CLASSROOM A116 235 A 10"ø 235 A 10"ø 235 A 10"ø A 12x12 SA CLASSROOM A112 16x16 A 16x16 C A 230 10"ø 230 10"ø A 16x16 C 1" CD CORRIDOR A100d DN DN 12"ø SA 230 10"ø 230 10"ø A CLASSROOM A111 T RTU-2 230 A 10"ø 1" CD 1 335 10"ø C B 16x16 7 A 34x26 SA CLASSROOM A117 F 8x8 18x20 SA 24x20 SA 335 10"ø D STORAGE A118 38x24 RA 200 E 8x8 DN 18x12 SA 24x14 SA 9 DN 18x12 SA T 9 DN F RTU-3 20"ø SA 3 16"ø SA BOD 12'-0" AFF 46x34 DN E 290 10x10 450 BOYS RR 10x10 A122 180 8"ø 12x10 EA CLASSROOM A110 14x14 SA 1" CD DN DN 18x12 SA 9 9 DN 35 B 6"ø DN DN UNSX RR A120 195 E 10x10 195 E 10x10 E BOD 12'-0" AFF 195 10x10 415 E 10x10 290 E 18"ø SA 10x10 E 290 10x10 195 E 10x10 75 D 6x6 35 6"ø 18x12 SA 9 UNSX RR A121 B E 12"ø SA 12"ø SA E 295 E 10x10 295 E 10x10 9 170 10x10 9 UNSX RR WAH A126 4 170 E 10x10 260 E 10x10 18"ø SA 20"ø SA BOD 12'-0" AFF 540 12"ø E 195 10x10 E 195 10x10 E 295 10x10 195 10x10 180 10x10 E 180 10x10 195 10x10 4TH-5TH LARGE GROUP A119 12"ø SA 295 E 10x10 E E 180 E 10x10 250 10x10 E 250 10x10 38x26 RA 1 34x26 SA A 250 10"ø E 9 ISSUE FOR PERMIT BID & CONSTRUCTION C 16x16 C 16x16 WL 2 1" CD 24x24 35 6"ø F UNSX RR 42x30 A128 260 E 10x10 170 E 10x10 B F 42x30 RTU-4 9 3 260 E 10x10 260 10x10 E 3 C 20"ø SA 265 10x10 E 265 10x10 E E 12x12 SA 200 A 8"ø 265 10x10 E 20x18 RA 265 E 10x10 180 10x10 300 10x10 E 300 10x10 E E C 180 10x10 16x16 100 A 6"ø 300 10x10 250 E 10x10 2 RE: M-202 12"ø SA 8x12 EA 12x12 EA A 540 12"ø 14x12 EA E 180 10x10 10x8 EA T RTU-11 EF 7 AH-3 H 20x20 CLASSROOM A104 E 250 10x10 D C 24x24 2300 48x18 E 310 310 A 10"ø 10"ø 8x10 SACLASSROOM A103 225 D 8x8 105 B 6"ø GIRLS RR A102 26x16 RA 6x10 SA 1" CD BOYS RR A101 105 B 6"ø 10x8 EA 20x22 RA A 75 6"ø 7 5 AQUARIUM SERVICE 103 COMMONS 101 3 75 6x6 UNISEX RR 104 40 B 6"ø D 1 5 5 1 225 8x8 DN 40 B 6"ø 3 UNISEX RR 105 2300 E 48x18 75 D 6x6 DN 44x16 RA RTU-10 44x16 SA 6 26x26 RA 6 8 T 12x14 EA 1" CD T 20x20 SA RTU-5 STOR A130 10 310 10"ø 520 A 12"ø 12"ø SA E 3 12x14 SA T 8 12x12 SA 12 A 11 265 E 10x10 300 10x10 3/4" CD C 16x16 A 12"ø SA LIBRARY 102 AH 1 6"ø SA 1 CORR A100b 8x6 EA 14"ø SA 180 10x10 12x12 SA F 48x18 310 10"ø M 6"ø EA 400 18x8 30x14 RA A 265 10x10 E 265 E 10x10 265 E 10x10 100 A 6"ø 10 210 8"ø 10"Ø OA 3 18x18 SA DN 8 24x22 RA VEST 115 A 14x18 RA 12"ø SA 1 M 10x10 SA 16x16 SA 170 10x10 135 8"ø (TYP 5) 2 BOD 12'-0" AFF K-3RD LARGE GROUP A124 T CORR A100a 210 8"ø A E UNSX RR A129 18"ø SA BOD 12'-0" AFF 18"ø SA E 16x16 6x10 SA 16x20 SA 35 B 20x14 SA 6"ø 9 4 G 200 STORAGE E 8x8 A127 75 75 D D 6x6 6x6 EA 6x6 34x18 RA 24x14 SA 8 4 16x16 RA 24x22 SA WL 1 CLASSROOM A105 1 295 10x10 RTU-6 RE: M-201 250 10"ø 18"ø SA 180 10x10 E 22x20 SA 540 12"ø 230 10"ø C 12"ø SA E A 12x12 SA CLASSROOM A107 18x16 RA 12"ø SA 520 12"ø 12"ø SA E A CLASSROOM A109 230 10"ø 34x18 RA F 12x10 BOD 12'-0" AFF 14"ø SA CORR A100e 290 E 10x10 250 10"ø 1" CD T 12"ø SA 12"ø SA 295 10x10 35 B 6"ø 16"ø SA 195 10x10 CLASSROOM A108 E 415 E 10x10 E 75 D 6x6 35 B 6"ø UNSX RR A125 BOD 12'-0" AFF E A 200 E 8x8 16x20 SA 75 24x14 SA D 6x6 20x14 SA ELEC 3/4" CD A127a 16x16 SA 195 10x10 26x20 RA A A 24x22 SA E 290 E 10x10 235 A 10"ø 5 16"ø SA 195 E 10x10 A 235 10"ø 16x16 SA 20x18 RA GIRLS RR 450 D A123 12x12 8x10 EA A BOD 12'-0" AFF 180 B 8"ø A 16x16 C 12x10 EA 16x14 EA 75 D 6x6 18x20 SA 14x18 SA 195 E 10x10 BOD 12'-0" AFF 235 A 10"ø 18x18 SA 1 16x16 C 6x10 SA 16"ø SA 290 E 10x10 235 10"ø 16x16 SA 2 24x22 SA DN A C 16x16 7 A 235 10"ø 24x20 SA C 540 A 12"ø 235 A 10"ø 12x12 SA 24x16 RA CLASSROOM A115 T 235 A 10"ø 16x14 SA 26x20 RA CLASSROOM CLASSROOM A113 A114 1 RTU-1 C 24x24 235 A 10"ø 18x18 SA 16x16 SA C 16x16 A 230 10"ø C 16x16 235 A 10"ø 235 A 10"ø 1991 FM 158, BRYAN, TX 77845 270 A 10"ø CENTRAL BAPTIST CHURCH CHILDRENS BUILDING 270 A 10"ø 26x16 RA 34x20 SA RE: M-201 RE: M-202 5.8 No. Date Revision RAC Drawn JRM 1 FLOOR PLAN - AREA A MECHANICAL Checked WAS Approved Scale: 3/32" = 1'-0" FLOOR PLAN AREA A MECHANICAL Project No. Date Last Revision 15187.00 05/11/2016 M-201 TRUE NORTH PLAN NORTH printed5/11/2016 12:26:24 PM 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 KEYNOTES(THISSHEET) GENERAL NOTES 1. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 36" IN FRONT OF ALL ELECTRICAL DISCONNECTS. 2. CONTRACTOR SHALL OBSERVE ALL MANUFACTURER CLEARANCE AND INSTALLATION GUIDELINES FOR MECHANICAL EQUIPMENT. KEYVALUE 1 2 3 4 CONDENSATE FROM COOLING COILS SHALL BE COLLECTED PER LOCAL CITY REQUIREMENTS. 4. MATERIALS, EQUIPMENT OR LABOR NOT INDICATED BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE INSTALLATION SHALL BE PROVIDED. DRAWINGS AND SPECIFICATIONS DO NOT UNDERTAKE TO INDICATE EVERY ITEM OF MATERIAL, EQUIPMENT, OR LABOR REQUIRED TO PRODUCE A COMPLETE AND PROPERLY OPERATING INSTALLATION. 5. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT EXACT CONDITIONS. THE LOCATION OF EQUIPMENT, DUCTWORK, ETC. IS APPROXIMATE ONLY. THE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT TO BE SCALED. SCALES ARE SHOWN FOR REFERENCE AND APPROXIMATION ONLY. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONAL DATA OF BUILDING COMPONENTS. 6. INSTALL ALL DUCTWORK AS TIGHT TO STRUCTURE AS POSSIBLE, IN ORDER TO MAXIMIZE CEILING HEIGHTS. 7. PROVIDE ALL OFFSETS AND TRANSITIONS IN DUCTWORK AS NEEDED TO MAINTAIN CEILING HEIGHTS AND TRANSITION OVER OR UNDER DUCTWORK AND OTHER BUILDING SYSTEMS, WHETHER SHOWN ON DRAWINGS OR NOT. 8. COORDINATE DUCTWORK WITH STRUCTURE, LIGHTING, SPRINKLERS, ETC. PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL MAKE EVERY EFFORT TO INSTALL DUCTWORK IN ORDER TO MINIMIZE DUCT TRANSITIONS, FITTINGS, AND ELBOWS AS MUCH AS POSSIBLE TO REDUCE SYSTEM STATIC PRESSURE. 10. ROUND AND RECTANGULAR ELBOWS SHALL BE IN STRICT CONFORMANCE OF THE SPECIFICATIONS. SEGMENTED ELBOWS ARE NOT ALLOWED. 11. CONVERGING AND DIVERGING AIRFLOWS SHALL BE PROVIDED WITH FITTINGS CONFORMING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE", LATEST EDITION, TO MINIMIZE SYSTEM PRESSURE DROP. 12. NOT ALL VOLUME CONTROL DAMPERS ARE INDICATED ON THE DRAWINGS. PROVIDE DAMPERS PER THE SPECIFICATIONS AND AS REQUIRED FOR BALANCING MAIN AND BRANCH TAKE-OFF AIRFLOWS TO THE DOWNSTREAM CFM SHOWN. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING COORDINATION DRAWINGS TO SCALE, AS REQUIRED, USING INPUT FROM ALL OTHER TRADES PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK. CONTRACTOR DRAWINGS SHALL INDICATE DUCT INSTALLATION IN CONGESTED SPACES, INDICATING COORDINATION WITH GENERAL CONSTRUCTION, BUILDING COMPONENTS, CEILING ELEVATIONS, AND OTHER BUILDING SERVICES. INDICATE PROPOSED CHANGES TO DUCT LAYOUT. 14. MOUNT THERMOSTATS AT 46" AFF AND 8" FROM THE EDGE OF THE WALL. COORDINATE LOCATIONS WITH OWNER AND ARCHITECT PRIOR TO INSTALLATION. 15. PROVIDE 1" DOOR UNDERCUT UNDER RESTROOM DOORS FOR MAKEUP AIR. 5 6 7 8 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 3. NOTE OFFSET, TRANSITION AND CONNECT SUPPLY AND RETURN DUCTWORK UP TO ROOFTOP UNIT. REFER TO ARCHITECTURAL ELEVATIONS FOR AIR DEVICE LOCATIONS. OFFSET, TRANSITION AND CONNECT EXHAUST DUCT UP TO FAN ON ROOF. COORDINATE LOCATION OF HEATER WITH SPRINKLER CONTRACTOR PRIOR TO INSTALLATION. MOUNT HEATER 24" AFF. 4" ROUND DRYER EXHAUST DUCT FROM VENT BOX ROUTED TO EXTERIOR WALL CAP. CONDENSATE DRAIN DOWN TO TAILPIECE. COORDINATE WITH PLUMBING FOR LOCATION. CONDENSATE DRAIN DOWN TO JANITOR SINK. COORDINATE WITH PLUMBING FOR EXACT LOCATION. ROUTE DUCT THROUGH OPENING IN JOIST. KEY PLAN A RE: M-202 12x12 EA 12x14 EA PRE-SCHOOL B166 275 A 10"ø B RR B167 40 6"ø A 255 10"ø A 365 10"ø PANTRY 112B 50 D 6x6 BREAK RM 112A 1 A C 12x12 275 10"ø 365 10"ø 14x12 SA DN 10x12 SA C 12x12 T 230 10"ø A 7 ELEC 110 WAH 2 14x14 C 10x10 EA WOMEN 80 A134 B 150 6"ø D 8x8 150 D 8x8 8x8 EA 1" CD 8x8 EA 3/4" CD 16x14 SA A 10x10 EA 80 MENS B 6"ø A133 RESOURCE A135 7 3/4" CD PRE-SCHOOL B168 255 A 10"ø 24x20 RA IT/AVL 111 1" CD 22x20 SA 12x12 RA JAN 109 6x10 EA 8x8 EA 1" CD 1" CD 150 D 8x8 MENS B103 80 6"ø B C 8x8 24x24 230 10"ø 10x12 SA 75 D 6x6 RR B158 1 34x24 RA 325 10"ø A A 40 B 6"ø STOR B165b A A 14x16 SA 24x24 C B ADULT RR B169 75 D 8x8 50 6"ø A 26x20 RA PRE-SCHOOL B152 50 230 B A 6"ø 10"ø RTU-16 16x16 325 A 10"ø 325 A 10"ø PRE-SCHOOL B155 C 150 D 8x8 10x12 SA 10x12 SA 235 10"ø 235 A 10"ø A 18x14 RA 16x16 8x6 EA 12x12 SA PRE-SCHOOL 300 B153 A 50 10"ø B 6"ø RR B154 A DN 300 A 10"ø 12x12 E 500 18x10 E 500 18x10 500 18x10 E RR B151 150 8x8 C 8x8 6 230 A 10"ø 18x16 SA 8x12 EA DN DN C 90 6"ø STOR B149 A 175 8"ø A 10x10 RA PRE-SCHOOL LARGE GROUP 40 B130 B 6"ø PRE-SCHOOL 185 A PLAY 8"ø B133 STOR B131 310 10"ø DN 18x18 SA A 16x16 SA 10x12 SA A 185 8"ø RR B135 185 A 8"ø 18x18 RA DN C C 16x16 12x12 RA 24x22 SA C 3 OPEN AREA B100n DN DN 500 12"ø 8x12 EA 12x12 SA C A OFFICES B142 16x16 SA 270 A 10"ø 8"ø SA C 10x10 C 16x16 1 ELEC. B148 A 3/4" CD 300 10"ø 295 A 10"ø 18x14 RA 10x10 35 6"ø B A C 10x10 DN B 40 6"ø STOR B134 A 40 6"ø B 50 6"ø A RR B146 C C 10x12 SA RR B128 150 D 8x8 16x16 RA 10x10 8x12 SA A 295 10"ø 230 10"ø C A C 16x16 10x10 230 10"ø D OFFICE B139 150 8x8 OFFICE B138 16x16 240 A 10"ø CORRIDOR B100a PRE-SCHOOL B127 1 80 A 6"ø 1" CD A 240 A 10"ø 50 6"ø 8x8 STORAGE B126 OFFICE B137 RES. B117 300 10"ø PRE-SCHOOL B125 A 12x12 310 A 10"ø 310 10"ø 24x24 C 24x24 VEST 100 1350 30x12 4 2 16x16 150 8"ø (TYP 4) A 12x12 RA 12x12 235 10"ø 235 10"ø 24x18 RA A 8x8 EA NURSERY B106 DN 22x18 RA 20x18 SA 75 D 8x8 12x12 SA 1 3 STOR B121 150 8"ø (TYP 4) A 6 8x10 SA 16x16 RA RTU-15 STOR B171 A 235 10"ø PRE-SCHOOL B118 A 150 8x8 10x12 SA T 20x18 SA 500 12"ø OPEN AREA B100d 14x14 SA C 16x16 NURSERY B107 C 12x12 SA 24x24 2 16x16 RA T 8x8 EA 290 10"ø NURSERY B105 C 16x16 12x12 RA 14x12 SA ADULT RR C 12x12 B170 50 B 6"ø RR B119 C 8x8 12x12 SA 12x12 12x12 SA 290 A 10"ø C C RTU-19 12x12 C 12x12 290 A 10"ø 12x12 SA A 350 10"ø A 350 10"ø 6x12 SA A 50 6"ø 290 10"ø PRE-SCHOOL B123 RR B124 50 6"ø 6x12 SA FIRE RISER B122 A A D 16x14 SA E C 1350 30x12 2 150 A 8"ø (TYP 4) 18x16 RA C A 50 B 6"ø 300 10"ø 14x12 SA B DRYER VENT CAP. REFER TO DETAIL. 16x16 E 20x20 SA NURSERY PLAY B111 C 12x12 D C 2300 48x18 1 10x12 EA 7 LAUNDRY 410 B136 A 12"ø 5 230 10"ø 50 6"ø 310 10"ø PRE-SCHOOL B120 16x16 NURSERY B104 C 12x12 235 235 A A 10"ø 10"ø NURSERY B112 STROLLER STORAGE B116 110 A 8"ø A A 1" CD A 235 A 10"ø T C E 16x16 SA RTU-18 20x16 SA 2 125 8"ø (TYP 4) 1" CD OPEN AREA 8x8 EA B100g A 10x10 310 10"ø 235 A 10"ø 18x18 SA 16x16 12x12 RA 14x12 SA 8x6 EA 1" CD 12x12 SA C T A C A 5 T 195 8"ø 500 12"ø 24x24 RTU-9 250 10"ø 12x12 RA C 12x12 8x12 SA A 12x12 CORRIDOR B100h C RTU-14 16x14 SA C B 18x18 SA C 28x16 SA CORR B100m 14x12 SA 14x12 RA RTU-17 14x14 24x24 12x12 SA NURSERY B113 1 A 190 8"ø 24x22 SA PRE-SCHOOL B129 240 A 10"ø PRE-SCHOOL B145 PRE-SCHOOL B147 6 C 3 240 10"ø 35 B 6"ø 75 6x6 C 75 8x8 D 22x20 RA ADULT RR B140 D 14x14 95 6"ø A 75 D 6x6 ADULT RR B141 95 6"ø 14x14 SA 250 10"ø A 24x16 RA 235 A 10"ø NURSERY B115 310 10"ø A 8x12 SA 300 10"ø 16x16 110 18x16 RA A 8"ø 6x10 EA 8x8 EA 16x16 RESOURCE B143 OFFICES B144 270 A 10"ø 310 10"ø 10x12 SA A B 250 250 A 10"ø NURSERY 10"ø B114 1" CD C 12x12 190 8"ø A 14x12 SA 235 10"ø PRE-SCHOOL B161 A 235 10"ø DN T A A 195 A 8"ø 185 8"ø A 6x12 SA A RTU-12 12x12 SA C T 1 C 10x10 CORR. B100k PRE-SCHOOL B159 C 16x16 16x14 SA 300 10"ø 180 8"ø ISSUE FOR PERMIT BID & CONSTRUCTION RTU-8 C 24x24 34x26 RA 6 A 10x14 EA 10x12 SA 16x14 SA DN WAH 1 150 D 8x8 235 10"ø 6x12 SA 235 A 10"ø 6x12 SA C 10x10 A 16x14 SA 150 8x8 RR B160 40 B 6"ø A C 16x16 230 10"ø D 8x8 EA D DN 24x24 COMMONS 101 8 8x10 SA 8x8 EA PRE-SCHOOL B163 24x20 SA PRE-SCHOOL B150 16x14 RA T CHECK-IN 106 C A 6x12 SA 1 325 10"ø C 36x36 F 20x20 RA B 5.8 34x20 SA INDOOR PLAY 107 2 DN 28x20 SA 20x18 SA A RESOURCE B132 180 8"ø 8x8 EA DN 175 A 8"ø 12x12 RA 230 10"ø C 8x8 14x14 RA A PRE-SCHOOL PLAY B162 20x12 SA 235 10"ø 480 12"ø 1" CD C 235 10"ø 6x12 SA PRE-SCHOOL B165 OPEN AREA B100p 325 A 10"ø 1" CD 40 B 6"ø RR B164 A 175 8"ø A 10x6 EA A C 10x10 12x12 SA 175 A 8"ø 175 A 8"ø 30x24 SA C 16x16 325 10"ø 500 18x10 E 26x26 RA C 34x26 SA 14x12 SA 6 A 12x14 SA 500 18x10 T 3 40 B 6"ø 175 A 8"ø STOR B157 DN 480 12"ø E (TYP.) DN 10x12 EA 10x10 EA 18x12 RA 230 10"ø 230 10"ø 40 B 6"ø A T 20x14 SA 24x22 RA CORR. B100r A 230 10"ø A A DN RTU-13 C 20x20 C 20x20 310 A 10"ø 12"ø SA 14x16 RA 230 10"ø A 14x14 SA 12"ø SA 2 500 18x10 E 16x16 SA PRE-SCHOOL LARGE GROUP B156 8x12 SA A 150 8x8 80 B 6"ø WOMEN B102 14x12 SA 480 A 12"ø 230 10"ø 480 12"ø A 90 6"ø 28x24 SA A ACTIVITY A132 300 A 10"ø C 8x8 MOTHERS B101 1 50 A 6"ø CORR. B100b RE: M-202 26x16 RA C 24x24 DN 26x14 RA C A RE: M-201 12x12 SA DN D WAH 3 RTU-7 16x16 SA 80 A 6"ø 10x12 SA 150 D 8x8 14x14 SA FIRST AID16x16 SA 108 8x12 EA 1 1991 FM 158, BRYAN, TX 77845 3 CENTRAL BAPTIST CHURCH CHILDRENS BUILDING RE: M-201 4 EH 1 NURSERY B110 290 10"ø A NURSERY B109 6x12 SA 290 10"ø No. Date Revision NURSERY B108 1 150 8x8 RAC Drawn JRM Checked A A.1 B C C.1 C.9 1 D D.8 E E.6 F F.1 G G.1 G.2 G.7 H H.1 H.5 J J.8 WAS K Approved FLOOR PLAN AREA B MECHANICAL FLOOR PLAN - AREA B MECHANICAL Scale: 3/32" = 1'-0" Project No. Date Last Revision 15187.00 05/11/2016 M-202 TRUE NORTH PLAN NORTH printed5/11/2016 12:26:34 PM 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 KEYNOTES(THISSHEET) GENERAL NOTES KEYVALUE 1 2 3 CONTRACTOR SHALL MAINTAIN A MINIMUM OF 36" IN FRONT OF ALL ELECTRICAL DISCONNECTS. 2. REFER TO ARCHITECTURAL PLANS FOR EXACT PLACEMENT OF MECHANICAL EQUIPMENT ON ROOF. COORDINATE WITH STRUCTURAL. 3. CONTRACTOR SHALL OBSERVE ALL MANUFACTURER CLEARANCE AND INSTALLATION GUIDELINES FOR MECHANICAL EQUIPMENT. 4. CONDENSATE FROM COOLING COILS SHALL BE COLLECTED PER LOCAL CITY REQUIREMENTS. 5. MATERIALS, EQUIPMENT OR LABOR NOT INDICATED BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE INSTALLATION SHALL BE PROVIDED. DRAWINGS AND SPECIFICATIONS DO NOT UNDERTAKE TO INDICATE EVERY ITEM OF MATERIAL, EQUIPMENT, OR LABOR REQUIRED TO PRODUCE A COMPLETE AND PROPERLY OPERATING INSTALLATION. 6. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT EXACT CONDITIONS. THE LOCATION OF EQUIPMENT IS APPROXIMATE ONLY. THE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT TO BE SCALED. SCALES ARE SHOWN FOR REFERENCE AND APPROXIMATION ONLY. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONAL DATA OF BUILDING COMPONENTS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING COORDINATION DRAWINGS TO SCALE, AS REQUIRED, USING INPUT FROM ALL OTHER TRADES PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK. CONTRACTOR DRAWINGS SHALL INDICATE DUCT INSTALLATION IN CONGESTED SPACES, INDICATING COORDINATION WITH GENERAL CONSTRUCTION, BUILDING COMPONENTS, CEILING ELEVATIONS, AND OTHER BUILDING SERVICES. INDICATE PROPOSED CHANGES TO DUCT LAYOUT. 8. FALL PROTECTION BY OTHERS MAINTAIN 42" HIGH RAILING OR KEEP EQUIPMENT 10'-0" AWAY FROM EDGE OF BUILDING. 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 1. NOTE MANUFACTURERS RECOMMENDED SERVICE CLEARANCE. 10' OUTSIDE AIR CLEARANCE. EXHAUST AND PLUMBING VENTS SHALL NOT BE LOCATED IN THIS AREA. ROUTE CONDENSATE DOWN THROUGH ROOF CURB. KEY PLAN A B 9 3 3 RTU 2 RTU 1 HP 1 8 EF 1 1 CU 4 (TYP.) RTU 4 3 3 RTU 3 3 EQUIPMENT CURB. REFER TO DETAIL RTU 5 7 2 (TYP.) EF 2 1991 FM 158, BRYAN, TX 77845 CENTRAL BAPTIST CHURCH CHILDRENS BUILDING ISSUE FOR PERMIT BID & CONSTRUCTION RTU 11 3 1" CD RTU 10 3 EF 3 6 RTU 9 RTU 6 No. Date 3 RE: M-301 RE: M-301 RE: M-302 RE: M-302 5.8 Revision RAC Drawn JRM Checked WAS C C.1 C.9 D D.8 E E.6 F F.1 G G.1 G.2 G.7 H H.1 H.5 J J.8 Approved K ROOF PLAN AREA A - MECHANICAL 1 ROOF PLAN - AREA A - MECHANICAL Scale: 3/32" = 1'-0" Project No. Date Last Revision 15187.00 05/11/2016 M-301 TRUE NORTH PLAN NORTH printed5/11/2016 12:26:40 PM KEYVALUE 1 2 3 CONTRACTOR SHALL MAINTAIN A MINIMUM OF 36" IN FRONT OF ALL ELECTRICAL DISCONNECTS. 2. REFER TO ARCHITECTURAL PLANS FOR EXACT PLACEMENT OF MECHANICAL EQUIPMENT ON ROOF. COORDINATE WITH STRUCTURAL. 3. CONTRACTOR SHALL OBSERVE ALL MANUFACTURER CLEARANCE AND INSTALLATION GUIDELINES FOR MECHANICAL EQUIPMENT. 4. CONDENSATE FROM COOLING COILS SHALL BE COLLECTED PER LOCAL CITY REQUIREMENTS. 5. MATERIALS, EQUIPMENT OR LABOR NOT INDICATED BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE INSTALLATION SHALL BE PROVIDED. DRAWINGS AND SPECIFICATIONS DO NOT UNDERTAKE TO INDICATE EVERY ITEM OF MATERIAL, EQUIPMENT, OR LABOR REQUIRED TO PRODUCE A COMPLETE AND PROPERLY OPERATING INSTALLATION. 6. THE DRAWINGS ARE DIAGRAMMATIC AND DO NOT NECESSARILY DEPICT EXACT CONDITIONS. THE LOCATION OF EQUIPMENT IS APPROXIMATE ONLY. THE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT TO BE SCALED. SCALES ARE SHOWN FOR REFERENCE AND APPROXIMATION ONLY. REFER TO THE ARCHITECTURAL DRAWINGS FOR DIMENSIONAL DATA OF BUILDING COMPONENTS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING COORDINATION DRAWINGS TO SCALE, AS REQUIRED, USING INPUT FROM ALL OTHER TRADES PRIOR TO FABRICATION AND INSTALLATION OF DUCTWORK. CONTRACTOR DRAWINGS SHALL INDICATE DUCT INSTALLATION IN CONGESTED SPACES, INDICATING COORDINATION WITH GENERAL CONSTRUCTION, BUILDING COMPONENTS, CEILING ELEVATIONS, AND OTHER BUILDING SERVICES. INDICATE PROPOSED CHANGES TO DUCT LAYOUT. 8. FALL PROTECTION BY OTHERS MAINTAIN 42" HIGH RAILING OR KEEP EQUIPMENT 10'-0" AWAY FROM EDGE OF BUILDING. NOTE MANUFACTURERS RECOMMENDED SERVICE CLEARANCE. 10' OUTSIDE AIR CLEARANCE. EXHAUST AND PLUMBING VENTS SHALL NOT BE LOCATED IN THIS AREA. ROUTE CONDENSATE DOWN THROUGH ROOF CURB. 2808 Fairmount Street, Suite 300 Dallas, Texas 75201 | 214.303.1500 1. 3300 West 7th Street, Suite 110 Fort Worth, Texas 76107 | 817.303.1500 KEYNOTES(THISSHEET) GENERAL NOTES KEY PLAN A B RE: M-301 RE: M-302 RE: M-301 RE: M-302 3 5.8 RTU 6 3 ISSUE FOR PERMIT BID & CONSTRUCTION CU 2 CENTRAL BAPTIST CHURCH CHILDRENS BUILDING RTU 8 CU 3 RTU 7 3 EQUIPMENT CURB. REFER TO DETAIL RTU 12 5 3 EF 4 1 (TYP.) RTU 13 3 RTU 14 3 4 1991 FM 158, BRYAN, TX 77845 EF 3 3 2 EF 6 EF 5 (TYP.) RTU 15 3 3 RTU 17 3 RTU 18 RTU 16 3 3 RTU 19 CU 1 2 EQUIPMENT CURB. REFER TO DETAIL No. Date Revision RAC Drawn JRM 1 Checked WAS Approved ROOF PLAN AREA B - MECHANICAL A A.1 B C C.1 C.9 D D.8 E E.6 F F.1 G G.1 G.2 G.7 H H.1 H.5 J J.8 K Project No. 1 ROOF PLAN - AREA B - MECHANICAL Date Last Revision Scale: 3/32" = 1'-0" 15187.00 05/11/2016 M-302 TRUE NORTH PLAN NORTH printed5/11/2016 12:26:47 PM