PACKAGED GASL" / ELECTRIC PACKAGED SERIES LG L SERIES® ROOFTOP UNITS − 60HZ ENGINEERING DATA Variable or Constant Air Volume 13 to 30 Tons Bulletin No. 210318 October 2004 Supersedes July 2004 Insulated Panels in all Conditioned Areas Copper Tube Coil with Enhanced Fins Humiditrol® Hot Gas Reheat Option Available (Not Shown) (Not available for all models) MERV 7 Filters Furnished (Optional MERV 11 Available) Thermally Protected Outdoor Coil Fan Motors with PVC Coated Fan Guard Independent Fan Motor Mount (Separate from fan guard) Hinged Access Panels with Quarter Turn latches Heavy Gauge Galvanized Steel Panels with Two−layer Enamel Paint Finish Intelligent Unit Controller Solid−State Microprocessor Provides Flexible Control of all Unit Functions and Diagnostics High and Low Pressure Switches Thermal Expansion Valves with Filter Drier R−410A Refrigerant Available (15, 20, 21 and 30 Ton High Efficiency CAV Models Only) Belt Drive Blowers Circuit Breaker, Disconnect and GFI Service Outlets Available Full Perimeter Base Rail with Rigging Holes and Fork Lift Slots Aluminized Steel Heat Exchanger (Optional Stainless Steel Available) Fully Insulated Base Refrigerant Service Valves Available Power/Gas Entry Through Base or Side of Unit Combustion Air Inducer Aluminized Steel Inshot Burners Copeland Scroll Compressors with Crankcase Heater Dual Stage Gas Valve with Manual Shut−Off ASHRAE 90.1 COMPLIANT NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 2004 Lennox Industries Inc. TABLE OF CONTENTS Application Guide − Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 85−87 Accessory Air Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 41−43 Blower Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 38−40 Control Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 53−61 Cooling Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 24−29 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 64−75 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 47−51 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 3−7 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 76−84 High Altitude Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 37 Humiditrol® Condenser Reheat Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 9−10 Humiditrol® Condenser Reheat Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 35−37 Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page −51−52 Model Number Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 8−13 Optional Disconnect Switch Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 46 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 14−23 Sound Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 51 Weight Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 62−63 MODEL NUMBER IDENTIFICATION L G C 240 S 2 B S 1 Y Voltage Y = 208/230V-3 phase-60hz G = 460V-3 phase-60hz J = 575V-3 phase-60hz Brand/Family L = L Series Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Nominal Cooling Capacity − Tons 156 = 13 Tons 180= 15 Tons 210 = 17.5 Tons 240 = 20 Tons 248 = 21 Tons 300 = 25 Tons 360 = 30 Tons Cooling Efficiency S = Standard Efficiency H = High Efficiency L Series Packaged Gas/Electric − 13 to 30 Tons / Page 2 Minor Design Sequence 1 = 1st Revision 2 = 2nd Revision 3 = 3rd Revision Heating Type L = Low Gas Heat, 1 Stage S = Standard Gas Heat, 2 Stage M = Medium Gas Heat, 2 Stage H = High Gas Heat, 2 Stage Blower Type B = Constant Air Volume (CAV) − Belt Drive V = Variable Air Volume (VAV) − Belt Drive Refrigerant Type 2 = R−22 4 = R−410A FEATURES AND BENEFITS CERTIFICATIONS ETL and CSA listed. Heating efficiency ratings verified by CSA. Components bonded for grounding to meet safety standards for servicing required by UL, CSA and National and Canadian Electrical Codes. 156 thru 248 models are certified in accordance with the ULE certification program, which is based on ARI Standard 340/360-2000. 300 and 360 models are tested at conditions included in ARI Standard 340/360−2000. ISO 9001 Registered Manufacturing Quality System. ENERGY STAR® certified units are designed to use less energy, help save money on utility bills, and help protect the environment. WARRANTY Limited ten years aluminized heat exchanger, limited fifteen years optional stainless steel heat exchanger. Limited five years on compressors. Limited three years on Integrated Modular Control. Limited one year all other covered components. COOLING SYSTEM Designed to maximize sensible and latent cooling performance at design conditions. Two efficiency levels provide flexibility. System can operate from 0°F to 125°F without any additional controls. Compressors Resiliently mounted on rubber grommets for quiet operation. Copeland Scroll compressors on all models for high performance, reliability and quiet operation. Compressor Crankcase Heaters Protects against refrigerant migration that can occur during low ambient operation. Thermal Expansion Valves Assures optimal performance throughout the application range. Removable element head. Filter/Driers High capacity filter/driers protect the system from dirt and moisture. High Pressure Switches Protects the compressor from overload conditions such as dirty condenser coils, blocked refrigerant flow, or loss of outdoor fan operation. Automatic reset Low Pressure Switches Protects the compressor from low pressure conditions such as low refrigerant charge, or low/no air flow. Automatic reset Freezestats Protects the evaporator coil from damaging ice build−up due to conditions such as low/no air flow, or low/no refrigerant charge. Coil Construction Copper tube construction, enhanced rippled−edge aluminum fins, flared shoulder tubing connections, silver soldered construction for improved heat transfer. Factory leak tested. Evaporator Coil Cross row circuiting with rifled copper tubing optimizes both sensible and latent cooling capacity. Low fin per inch count minimizes air pressure drop. Constant air volume (CAV) models have face−split evaporator coils. Variable air volume (VAV) models have row−split evaporator coils designed to keep condensate water off of an inactive part of the coil so the condensate will not re−enter the air stream. Condenser Coil Angled, slab design helps protect coil from possible contact or hail damage. Condensate Drain Pan Drain connection extends outside unit. Painted, galvanized pan with positive slope. Stainless steel drain pan available as a factory installed option. Outdoor Coil Fan Motors Thermal overload protected, totally enclosed, permanently lubricated ball bearings, shaft up, wire basket mount. Outdoor Coil Fan PVC coated fan guard furnished. Refrigerant Choice LGC180H, LGA240H, LGA248H, and LGA360H models can be ordered with R−22 (CAV and VAV models) or R−410A (CAV models only) refrigerant systems. REQUIRED SELECTIONS Cooling Capacity Specify the nominal cooling capacity of the unit Cooling Efficiency Specify either standard or high efficiency. Refrigerant Choice (LGC180H, LGA240H, LGA248H, and LGA360H Models Only) Specify R−22 (CAV and VAV models) or R−410A (CAV models only) refrigerant. OPTIONS / ACCESSORIES Factory Installed Discharge Air Temperature Sensor Sensor sends information to the IMC to cycle up to 4 stages of heating or cooling to maintain the discharge air setpoints for heating or cooling. Optional for CAV units (single zone or bypass zoning control). Automatically furnished with all Variable Air Volume (VAV) units. Sensor is shipped with the unit for remote field installation in the supply duct. Service Valves Fully serviceable brass valves installed in discharge & liquid lines. Not for use with Humiditrol equipped units. Four Stage Control Add−on board that enables the unit to operate four stages of cooling and four stages of gas heat when controlled by a 4−stage thermostat or aftermarket DDC control system. For 248H, 300H, 360H models only. Fresh Air Tempering Provides heating and cooling as needed to maintain the supply air temperature within a comfort range, regardless of the thermostat demand. Sensor ships with unit but must be field installed in the supply air duct. Requires change to IMC (ECTO) parameter in the field to activate this mode of operation. Stainless Steel Condensate Drain Pan Factory installed Factory or Field Installed Condensate Drain Trap Field installed only, may be factory enclosed to ship with unit. Available in copper or PVC. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 3 FEATURES AND BENEFITS HEATING SYSTEM Aluminized steel inshot burners, direct spark ignition, electronic flame sensor, combustion air inducer, redundant automatic single or dual stage gas valve with manual shut-off. Heat Exchanger Tubular construction, aluminized steel, life cycle tested. Stainless Steel Heat Exchanger is required if mixed air temperature is less than 45°F. Fan & Limit Controls Factory installed with fixed temperature setting. Heat limit controls protect against overheating. Safety Switches Flame roll−out switches, flame sensors and combustion air inducer proving switches protect system operation. All safety switches are monitored by the IMC unit controller and diagnostic errors are reported and recorded. REQUIRED SELECTIONS Gas Input − Order one: 169,000 Btuh Low Heat Gas Input (LGC156, LGC180 and LGC210 models only). 169,000 / 260,000 Btuh low/high fire − Standard Heat Gas Input. 234,000 / 360,000 Btuh low/high fire − Medium Gas Heat Input. 312,000 / 480,000 Btuh low/high fire − High Gas Heat Input (Not available for LGC156). OPTIONS / ACCESSORIES Factory Installed Discharge Air Temperature Sensor Sensor sends information to the IMC to cycle up to 4 stages of heating or cooling to maintain the discharge air setpoints for heating or cooling. Optional for CAV units (single zone or bypass zoning control). Automatically furnished with all Variable Air Volume (VAV) units. Sensor is shipped with the unit for remote field installation in the supply duct. Stainless Steel Heat Exchanger Required if mixed air temperature is below 45°F. Four Stage Control − Add−on board that enables the unit to operate four stages of cooling and four stages of gas heat when controlled by a 4−stage thermostat or aftermarket DDC control system. For 248H, 300H, 360H models only. Factory or Field Installed Fresh Air Tempering Provides heating and cooling as needed to maintain the supply air temperature within a comfort range, regardless of the thermostat demand. Sensor ships with unit but must be field installed in the supply air duct. Requires change to IMC (ECTO) parameter in the field to activate this mode of operation. Field Installed Combustion Air Intake Extensions Recommended for use with existing flue extension kits in areas where high snow drifts can block intake air. LPG/Propane Kits Conversion kit to field change over units from Natural Gas to LPG/Propane. Vertical Vent Extension Kit Exhausts flue gases vertically above unit. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 4 BLOWER A wide selection of supply air blower options are available to meet a variety of air flow requirements. Motor Overload protected, equipped with ball bearings. Belt drive motors are offered in several different sizes to maximize air performance. Motor Efficiency Specify standard or high. Supply Air Blower Forward curved blades, blower wheel is statically and dynamically balanced. Belt drive motors with adjustable pulley for speed change on CAV units. Blower assembly slides out of unit for servicing. Grease fittings furnished. REQUIRED SELECTIONS Supply Air Blower Specify Constant Air Volume (CAV) or Variable Air Volume (VAV). Order Standard or High Efficiency Blower motor (See Blower Data Table for specifications). NOTE − 575V VAV models are only available with high efficiency blower motors. Order one drive kit, see Drive Kit Specifications Table. OPTIONS / ACCESSORIES Factory Installed Supply Static Transducer Transducer sends information to the IMC to control VFD blower speed. Optional for CAV units (single zone or bypass zoning control). Automatically furnished with all VAV units. Transducer is shipped with the unit for remote field installation in the supply duct. Supply VFD Blower Bypass Control Allows variable air volume (VAV) unit to operate as a constant air volume (CAV) unit in case of variable frequency drive (VFD) failure. Field Installed Supply Static Limit Switch Field installed manual reset switch for supply static high pressure limit. Prevents exceeding pressure limit in supply air duct. Optional Mounting Kit includes tubing and adaptors. FEATURES AND BENEFITS CABINET Construction Heavy−gauge steel panels and full perimeter heavy−gauge galvanized steel base rail provides structural integrity for transportation, handling, and installation. Base rails have rigging holes. Three sides of the base rail have fork slots. Raised edges around duct and power entry openings in the bottom of the unit provide additional protection against water entering the building. Air−Flow Choice Units are available in down−flow (vertical) or horizontal return air flow configuration. Horizontal air flow requires Horizontal Roof Curb. Horizontal Return Air Panel Kit is also required if converting a down−flow configured unit to horizontal air flow. Power and Gas Entry Electrical and gas lines can be brought through the unit base or through horizontal access knock−outs. Exterior Panels Constructed of heavy−gauge, galvanized steel with a two−layer enamel paint finish. Insulation All panels adjacent to conditioned air are fully insulated with non−hygroscopic fiberglass insulation. Unit base is fully insulated. The insulation also serves as an air seal to the roof curb, eliminating the need to add a seal during installation. Access Panels Hinged access panels are provided for 2 compressor/controls/heating areas, blower access and air filter/economizer access. All panels have seals and quarter−turn latching handles to provide a tight air and water seal. REQUIRED SELECTIONS Air Flow Configuration Specify horizontal or down−flow. OPTIONS / ACCESSORIES Factory Installed Corrosion Protection Phenolic epoxy coating, applied to condenser coils (with painted base section) and evaporator coils (with painted base and painted blower housings), factory applied to either section or both sections. Field Installed Coil Guards Painted, galvanized steel wire guards to protect outdoor coil. Not used with Hail Guards. Grille Guards Protects the space between outdoor coils and main cabinet. Hail Guards Constructed of heavy gauge steel, painted to match cabinet, helps protect outdoor coils from hail damage. Not used with Coil Guards. Horizontal Return Air Panel Kit Required for horizontal applications with Horizontal Roof Curb, contains panel with return air opening for field replacement of existing unit panel and panel to cover bottom return air opening in unit, see dimension drawings. AIR FILTERS Disposable 2 inch (51 mm) pleated MERV 7 filters (Minimum Efficiency Reporting Value based on ASHRAE 52.2). OPTIONS / ACCESSORIES Factory or Field Installed MERV 11 Filters Disposable 2 inch pleated MERV 11 filters (Minimum Efficiency Reporting Value based on ASHRAE 52.2). L Series Packaged Gas/Electric − 13 to 30 Tons / Page 5 FEATURES AND BENEFITS CONTROLS Intelligent Unit Controller The Integrated Modular Control (IMC) is a solid−state microprocessor−based control board that provides flexible control of all unit functions. All control voltage is provided via a 24V (secondary) transformer with built−in circuit breaker protection. Built-in functions include: Blower On/Off Delay − Adjustable time delay between blower on and off. Blower Air Delivery Options − Three air delivery options; single zone CAV, bypass zoning with bypass dampers, and modulating VAV with VFD. Built-in Control Parameter Defaults − No programming required for standard CAV models. Compressor Time−Off Delay − Adjustable time delay between compressor shutoff and start up. DDC Compatible − Various third party DDC controllers can be factory or field installed. Refer to the Unit Controllers section for details. Dirty Filter Switch Input − When a Dirty Filter Switch is installed, the IMC will signal when the indoor blower static pressure increases, indicating a dirty filter condition. Switch is optional and can be factory or field installed. Discharge Air Temperature Control − The IMC will cycle up to 4 stages of heating or cooling to maintain the discharge air setpoints for heating or cooling. Optional for CAV units (single zone or bypass zoning control). Sensor is automatically furnished with all Variable Air Volume (VAV) units. Sensor is shipped with the unit for remote field installation in the supply duct. Display/Sensor Readout − Displays control parameters, diagnostic codes, and sensor readings. The IMC unit controller displays temperature readings from return air, supply air, and outdoor air sensors that are furnished as standard on all L Series units. IMC will also display readings from optional sensors such as zone sensors, CO2 sensors or relative humidity sensors. Economizer Control Choice − The economizer is controlled by an add−on board to the IMC. The economizer control board has several choices for controlling the economizer. See Economizer / Outdoor Air / Exhaust Options. Fresh Air Tempering − Provides heating and cooling as needed to maintain the supply air temperature within a comfort range, regardless of the thermostat demand. Sensor ships with unit but must be field installed in the supply air duct. Requires change to IMC (ECTO) parameter in the field to activate this mode of operation. Extensive Unit Diagnostics − The IMC monitors all sensors and functions related to unit operation to provide critical information. The IMC will display detailed diagnostic information with over 80 diagnostic codes to pinpoint any problems and reduce troubleshooting time. All diagnostic codes are listed inside control access panel for easy reference. Exhaust Fan Control Modes − Fans controlled by fresh air damper position (non−VFD power exhaust) or building static differential pressure transducer. Permanent Diagnostic Code Storage − Maintains diagnostic codes through a power failure. Field Changeable Control Parameters − Over 200 different control parameters allow customization of the unit operation by changing delays, cooling stages, deadbands, and setpoints. Indoor Air Quality Input − The IMC is Demand Control Ventilation ready from the factory (optional field installed CO2 sensor required). Two modes of operation are available: setpoint and proportional. 1 − Setpoint − Opens the economizer dampers to full position when CO2 setpoint level is reached. 2 − Proportional − Opens the dampers at the first set point and gradually increases it as the CO2 level increases until the second setpoint is reached. Low Ambient Controls − Allows unit cooling operation down to 0°F. Gas Valve Time Delay Between First and Second Stage − Allows gradual increase of input rate. Minimum Compressor Run Time − Ensures proper oil return to the compressor. Network Capable − The IMC can be daisy chained to other L Series units or L Connection® Network controllers using twisted pair wire. Night Setback Mode − Adjusts setpoints, closes outdoor air dampers and operates the blower on demand, may be customized for special requirements. Return Air Temperature Limit Control − Allows the user to override the demands based upon the return air temperature during either heating or cooling operation. Helps protect against abnormal operating conditions in the event of a room sensor or thermostat failure. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 6 Safety Switch Input − Normally−closed digital input allows the IMC to respond to a external safety switch trip (phase protector, low voltage, etc.) shutting down unit operation. Service Relay Output − Digital output can indicate a critical error has occurred to an external control device. Can also be configured to energize based on relative humidity, indoor air quality, outdoor air temperature or unit operation. Smoke Alarm Mode − Control board has four choices for responding to a smoke alarm. 1 − Unit Off − unit will turn off. 2 − Positive Pressure − blower is energized, exhaust fan is de−energized, and the outdoor air dampers are opened. 3 − Negative Pressure − blower is energized, exhaust fan is energized, and the outdoor air dampers are closed. 4 − Purge − blower is energized, exhaust fan is energized, and the outdoor air dampers are opened. Staging − 2 heat/2 cool. Capable of up to 4 heat/4 cool with zone sensor or with optional Four Stage Control (FS1) board and 4 heat/4 cool thermostat or third party DDC control system. Strike Three" Protection − Ends cooling or heating operation when any of the following occurs three times (adjustable) within a thermostat cycle: low pressure trip, high pressure trip, heat limit trip, or freeze−stat trip. Gas Reheat − Control parameter option that allows simultaneous heating and cooling operation on CAV gas units for controlling humidity for process air applications such as supermarkets. Field installed relative humidity sensor or dehumidistat can be used. On−Demand Dehumidification − Monitors and controls condenser hot gas bypass operation with Humiditrol option. Prioritizes heat and cool demand with dehumidification demand. Reheat demand can be enabled by digital input or a field installed relative humidity sensor can be used. CAV models only. Thermostat Bounce Delay − Protects compressor from short cycling when mechanical thermostat is used. Warm-up Mode Delay − Adjustable time that the economizer dampers are kept in the closed position during morning warm−up. On−Board User Interface − Push−button, DIP switches used with three−digit display readout for field adjustment of control parameters. LED indicators for L Connection Network (transmit and receive) and for each thermostat input. FEATURES AND BENEFITS CONTROLS − CONTINUED ELECTRICAL PC Interface − PC with optional Unit Controller software may be used to field or remotely adjust parameters, read alarms, or display unit status. VAV Control − Supports variable air volume (VAV) units with variable frequency drive or constant air volume units with bypass zoning control system. Constant air volume bypass zoning control units require add−on control board. Zone Sensor Operation − Controls zone temperature with up to 4 stages of heating or cooling with optional zone sensor. Four Stage Control (FS1) Board is not required. OPTIONS / ACCESSORIES Factory Installed Four Stage Control Provides additional 24VAC thermostat inputs for 4 heat/4 cool thermostats and aftermarket DDC controls. Factory installed. Factory or Field Installed Blower Proving Switch Monitors blower operation, shuts down unit if blower fails. Factory installed. Dirty Filter Switch Senses static pressure increase indicating dirty filter condition. Indoor Air Quality (CO2) Sensor Monitors CO2 levels, reports to IMC board which adjusts economizer dampers as needed. Smoke Detector Photoelectric type, installed in supply air section or return air section or both sections Commercial Control Systems L Connection® Network Control system to complement the IMC in single zone applications. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See pages 53 − 55. Sectrat Commercial Zoning System Control system to complement the IMC in VFD, bypass zoning applications and single zone control. Options include local interface, software for local or remote communication, and hardware for networking other control functions. See Pages 56 − 58. Aftermarket DDC See Pages 59−60. Thermostats Control system and thermostat options. Aftermarket unit controller options. See Page 61. Field Installed Humidity Sensor Kit, Remote Mounted Humidity sensor required with factory installed Humiditrol Option. REQUIRED SELECTIONS Voltage Choice Specify 208/23V, 460V or 575V 3−phase−60hz when ordering base unit. OPTIONS / ACCESSORIES Factory Installed Circuit Breakers up to 250 Amp HACR circuit breaker without power distribution lugs. Accessible from outside of unit, spring−loaded weatherproof cover furnished. Main power to the unit is field connected to the circuit breaker which allows all power to be shutoff for service. Circuit breaker is sized to the unit maximum overcurrent protection (MOCP) size. Field Installed Disconnect Switch up to 250 Amp Accessible from outside of unit, spring loaded weatherproof cover furnished. Main power to the unit is field connected to the disconnect which allows all power to be shut off for service. See Optional Disconnect Switch Requirements table, Page 46 for field installed disconnect switches. GFI Service Outlets (2) 115v ground fault circuit interrupter (GFCI) type, field wired or unit powered. SERVICEABILITY Designed to streamline general maintenance and decrease troubleshooting time. Diagnostics IMC diagnostic codes pinpoint problems, minimizing troubleshooting time. Marked & Color−Coded Wiring All electrical wiring is color−coded and marked to identify which components it is connecting. Electrical Plugs Positive connection electrical plugs are used to connect common accessories or maintenance parts for easy removal or installation. Tool−less, Hinged Access Panels Large access panels are hinged and have quarter−turn, latching handles for quick and easy access to maintenance areas. Filter access panels are hinged for easy access to the filters. Blower Access Blower assembly slides out of the unit for easy access. Coil Cleaning Slab condenser coils allow easier cleaning. Standard Components A large number of common maintenance parts are standard throughout the entire range of sizes (3−30 tons), reducing the need to carry a lot of different parts to the job or in inventory. Compressor Compartment Compressors are located near the perimeter of the unit for easier access. Compressors are isolated from the condenser air flow allowing system operation checks to be done without changing the air flow across the outdoor coils. Thermal Expansion Valves Thermal expansion valves are located near the perimeter of the unit for easier access. Removable element head allows change out of element and bulb without removing the TXV. Service Valves (optional) Optional factory installed liquid and discharge service valves allow refrigerant to be isolated to the high side for service work on the low side of the refrigeration system. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 7 OPTIONS / ACCESSORIES ECONOMIZER/OUTDOOR AIR/EXHAUST Factory or Field Installed Economizer − Parallel gear driven action recirculated air and outdoor air dampers, plug-in connections to unit, nylon bearings, neoprene seals, 24 volt fully modulating spring return motor, adjustable minimum damper position, damper assembly slides in unit, outdoor air hood must be ordered separately, optional down-flow barometric relief dampers available, choice of economizer controls. The IMC add−on board for economizer control is included with the economizer. Control board has five choices for controlling the economizer (DIP switch selections). 1 − Differential Sensible Control − Factory setting. Uses the outdoor air and return air sensors that are furnished with the unit. The IMC compares the outdoor air and return air and using setpoints, enables the economizer when the outdoor air temperature is below the configured setpoint and cooler than return air. NOTE − Differential Sensible Control can be configured in the field to provide Offset Differential Sensible Control or Single Sensible Control. In Offset Differential Sensible Control mode, the economizer is enabled if the temperature differential (offset) between outdoor air and return air reaches the configured setpoint. In Single Sensible Control mode, the economizer is enabled when outdoor air temperature falls b 2 − Single Sensible Control − Differential Sensible Control above can be configured to Single Sensible Control. The IMC compares the outdoor air sensor temperature to the setpoint and enables the economizer when the outdoor air is cooler than the setpoint. 3 − Global Control − The IMC communicates with a DDC system with one global sensor (enthalpy or sensible) to determine whether outside air is suitable for free cooling on all units connected to the control system. Sensor must be field provided. 4 − Single Enthalpy Control − Outdoor air enthalpy sensor enables economizer if the outdoor enthalpy is less than the setpoint of the board. Factory installed. 5 − Differential Enthalpy Control − Two solid-state enthalpy sensors allow the economizer control board to select between outdoor air or return air, whichever has lower enthalpy. Factory installed. Outdoor Air Dampers (Manual or Motorized) − Linked mechanical dampers, 0 to 25% (fixed) outdoor air adjustable, installs in unit, outdoor air hood must be ordered separately. Motorized model features fully modulating spring return damper motor with plug−in connection. Manual model features a slide damper. Minimum mixed air temperature in heating mode 30°F. Maximum mixed air temperature in cooling mode: 90°F. Outdoor Air Hood − Required with LAREMD Economizer, LAOAD and LAOADM Outdoor Air Damper Sections, cleanable aluminum mesh fresh air filters furnished. Down−Flow Barometric Relief Dampers − Allows relief of excess air, aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, bird screen furnished. Dampers are required with Standard Static Power Exhaust Fans. Down−Flow Barometric Relief Damper Hood is available and must be ordered extra. Field Installed Down−Flow Barometric Relief Damper Hood − Field installed only. Use with Barometric Relief Dampers. Horizontal Barometric Relief Dampers − Aluminum blade dampers prevent blow back and outdoor air infiltration during off cycle, field installed in return air duct, bird screen furnished. Factory or Field Installed Standard Static Power Exhaust Fans − LAPEF18/24 models have two, 1/3 hp motors with 20 in., five blade propeller−type fans with a total power input of 750 Watts and a total air volume of 8630 cfm at 0 in. w.g. LAPEF30/36 models have three, 1/3 hp motors with 20 in., five blade propeller−type fans with a total power input of 1125 Watts and a total air volume of 12,800 cfm at 0 in. w.g. Motor is inherently protected and enclosed for maximum protection from weather, dust and corrosion. Installs internal to unit for down-flow applications only with economizer option, provides exhaust air pressure relief, interlocked to run when return air dampers are closed and supply air blower is operating, fan runs when outdoor air dampers are 50% open (adjustable), motor is overload protected, steel cabinet and hood painted to match unit, requires optional Down-flow Economizer Barometric Relief Dampers. See Standard Static Power Exhaust Blower Tables. High Static Power Exhaust Fans (248H/300H/360H Models Only − Choice of 50% (two, 2 hp motors) or 100% (three, 2 hp motors) centrifugal−type power exhaust. Overload and sub−fuse protected, equipped with ball bearings. Forward curved blades, blower wheel is statically and dynamically balanced. Constant volume high static power exhaust fans have adjustable pulleys for speed adjustments and are controlled by damper position. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 8 Variable air volume units (with variable frequency drive) have 100% capacity and can be ordered with an optional VFD bypass. Fans feature solid−state analog pressure transducer control which senses differential pressure between conditioned space and outdoor air to regulate fan speed. See Power Exhaust Blower Tables See High Static Power Exhaust Blower Tables. NOTE − High Static Power Exhaust is field installed but must be ordered at the same time as the rooftop unit so the unit can be factory configured for this option. Power Exhaust Control Options: Damper Position Control IMC controls exhaust fan based on economizer damper position. For Standard or High Static Power Exhaust (without VFD) Fans only. Differential Pressure Transducer Differential pressure transducer compares atmospheric pressure to conditioned space static pressure for controlling exhaust fan. Transducer is shipped with the unit for remote field installation. For High Static Power Exhaust (with VFD) fans only. CEILING DIFFUSERS Field Installed Ceiling Diffusers − Aluminum grilles, large center grille, insulated diffuser box with flanges, hanging rings furnished, interior transition (even air flow), internally sealed (prevents recirculation), adapts to T-bar ceiling grids or plaster ceilings. Transitions (Supply and Return) − Used with diffusers, installs in roof curb, galvanized steel construction, flanges furnished for duct connection to diffusers, fully insulated. ROOF CURBS Field Installed Nailer strip furnished, mates to unit, shipped knocked down. Standard Down−Flow − US National Roofing Contractors Approved, available in 14 inch and 24 inch heights Horizontal − Converts unit from down-flow to horizontal (side) air flow, return air is on unit, supply air is on curb, see dimension drawings. Curbs for rooftop applications meet National Roofing Code requirements. Requires Horizontal Return Air Panel. Available in 26 inch, 30 inch, 37 inch and 41 inch heights. Optional Insulation Kit is available to help prevent sweating. Cliplock 1000 Full Perimeter Down−Flow − Available in 14 inch, 18 inch and 24 inch heights. OPTIONS HUMIDITROL® HOT GAS BYPASS REHEAT OPTION 156H & 180H (3 Compressors) 210H, 240H & 300S (4 Compressors) R−22 CAV MODELS ONLY Factory installed option designed to control humidity. Provides dehumidification on demand using ASHRAE 90.1 recommended method for reheat with comfort conditioning humidity control. In addition to a thermostat/room sensor used for conventional operation, a humidity sensor is required and must be located in the occupied space. Humidity sensor provides input to the Integrated Modular Control (IMC) which is used to control activation of the dehumidification operation. Reheat controls are located in the compressor control section of the unit for easy access. Benefits Improves indoor air quality. Helps prevents damage due to high humidity levels. Improves comfort levels by reducing space humidity levels. Operation No Dehumidification Demand The unit will operate conventionally whenever there is a demand for cooling or heating and no dehumidification demand. Free cooling is only permitted when there is no demand for dehumidification. Dehumidification Demand Only The IMC is factory set at 60% relative humidity setpoint and can be adjusted at the IMC or with optional Unit Controller Software. For Network Control Panel (NCP) applications, the humidity setpoint can be adjusted at the NCP. The unit will operate in the dehumidification mode until the relative humidity of the conditioned space is 3% below the setpoint. Reheat operation will initiate on a dehumidification demand and does not require a cooling demand. The reheat coil is sized to offset most of the first stage sensible cooling effect during reheat only operation. This reduction in sensible cooling capacity extends compressor run time to control humidity when cooling loads are light. Solenoid valves divert hot gas from compressor 1 and compressor 2 to the reheat coil. The cooled and dehumidified air from the evaporator is then reheated as it passes through the reheat coil. The de−superheated and partially condensed refrigerant continues to the outdoor condenser coil where condensing is completed. The unit will continue to operate in this mode until the dehumidification demand is satisfied. A heating demand will terminate reheat operation. Dehumidification and Cooling Demand for 156H/180H three compressor models (Thermostat Application) If both a dehumidification and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 will operate in cooling. A demand for second stage cooling will terminate reheat operation until second stage cooling demand is satisfied. Dehumidification and Cooling Demand for 210H/240H/300S four compressor models (Thermostat Application) If both a dehumidification and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 and compressor 4 will operate in cooling. A demand for second stage cooling will terminate reheat operation until second stage cooling demand is satisfied. Dehumidification and Cooling Demand for 156H/180H three compressor models (Room Sensor Application) If both a dehumidification and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 will operate in cooling. A demand for second stage cooling will terminate reheat and compressor 3 operation and operate compressor 1 and compressor 2 in cooling until second stage cooling demand is satisfied. A demand for third stage cooling will operate compressor 1, compressor 2 and compressor 3 in cooling. Dehumidification and Cooling Demand for 210H/240H/300S four compressor models (Room Sensor Application) If both a dehumidification demand and a first stage cooling demand occur, the system will operate compressor 1 and compressor 2 in reheat and compressor 3 will operate in cooling. If a demand for second stage cooling is initiated, compressor 1 and compressor 2 will operate in reheat and compressor 3 and compressor 4 will operate in cooling. A demand for third stage cooling will terminate reheat and compressor 4 operation and operate compressor 1, compressor 2 and compressor 3 in cooling until third stage cooling demand is satisfied. A demand for fourth stage cooling will operate compressor 1, compressor 2, compressor 3 and compressor 4 in cooling. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 9 OPTIONS HUMIDITROL® HOT GAS BYPASS REHEAT OPTION (CONTINUED) REFRIGERANT SCHEMATIC (156H, 180H MODELS ONLY) NOTE: Refrigerant circuits one and two operates when there is a first-stage thermostat demand. MIXED INDOOR/OUTDOOR AIR 3 CONDENSER COIL 2 1 2 2 1 1 2 1 2 3 3 3 OUTDOOR AIR 1 REFRIGERANT CIRCUIT 1 2 REFRIGERANT CIRCUIT 2 3 REFRIGERANT CIRCUIT 3 REHEAT VALVE S CHECK VALVE THERMAL EXPANSION VALVE REFRIGERANT SCHEMATIC (210H, 240H and 300S MODELS ONLY) NOTE: Refrigerant circuits one and two operates when there is a first-stage thermostat demand. MIXED INDOOR/OUTDOOR AIR 4 3 CONDENSER COIL 2 1 2 2 1 1 2 4 3 2 4 3 1 OUTDOOR AIR 1 REFRIGERANT CIRCUIT 1 2 REFRIGERANT CIRCUIT 2 3 REFRIGERANT CIRCUIT 3 4 REFRIGERANT CIRCUIT 4 S REHEAT VALVE CHECK VALVE THERMAL EXPANSION VALVE L Series Packaged Gas/Electric − 13 to 30 Tons / Page 10 OPTIONs / ACCESSORIES 210 240 248 300H 360 f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f 1x 1x 1x 1x f 1x f f f f 1x 1x 1x 1x f 1x f f f 1x 1x 1x 1x f 1x f f f 1x 1x 1x 1x f 1x f f f 1x 1x 1x 1x f 1x f f f 1x 1x 1x 1x f 1x f f f 1x 1x 1x 1x f 1x f f f f f f f f f f f f f f f f f f f f f f f f f x x x x x x x x f x f f f f f f f f ⊗ f f x f f f f f f f f ⊗ f f x x x f x x x 300S 180 Item 156 L Series COOLING SYSTEM Standard Efficiency High Efficiency Condensate Drain Trap − Copper Condensate Drain Trap − PVC Corrosion Protection Service Valves Stainless Steel Condensate Drain Pan Factory installed only Factory installed only LTACDKC09/36 LTACDKP09/36 Factory installed only Factory installed only Factory installed only f HEATING SYSTEM Low Heat (1 stage) Standard Heat (2 stage) Medium Heat (2 stage) High Heat (2 stage) Combustion Air Intake Extensions LPG/Propane Conversion Kits Stainless Steel Heat Exchanger Vertical Vent Extension Factory installed only Factory installed only Factory installed only Factory installed only 89L97 130/260 (2 kits) kBtuh input − 72M94 180/360 (2 kits) kBtuh input − 72M95 240/480 (2 kits) kBtuh input − 72M96 Factory installed only 73M72 f f f 1x 1x 1x 1x f 1x Blower − SUPPLY MOTOR f f 2, 3, 5 hp Std. Efficiency CAV 2, 3, 5 hp High Efficiency CAV 3, 5, 7.5 hp Std. Efficiency CAV 3, 5, 7.5 hp High. Efficiency CAV 5, 7.5, 10 hp Std. Efficiency CAV 5, 7.5, 10 hp High Efficiency CAV 5, 7.5, 10 hp Std. Efficiency VAV with VFD (not 575V units) 5, 7.5, 10 hp High Efficiency VAV with VFD (not 575V units) Supply VFD Blower Bypass (VAV units with VFD only) AIR FILTERS MERV 11 High Efficiency 97L87 (24 x 24 x 2 order 6 per unit) 97L88 (20 x 20 x 2 order 12 per unit) f 88K52 88K53 78K78 86K30 88K25 88K26 38K47 38K48 x f f f f f CABINET Coil Guards Grille Guards Hail Guards Horizontal Return Air Panel Kit x x x x x x x x x x x x x x x x x x x x x x x CONTROLS Blower Proving Switch 30K49 f f f Dehumidistat − Supermarket reheat only 65F86 x x x Commercial Controls L Connection® Building Automation System f f f Novar® ETM−2051 Unit Controller f f f Sectrat Zoning System w/ VFD Control − C0CTRL05BD1L Sectrat Zoning System with Bypass Control − C0CTRL04BD1L f f f Sectrat Zoning System Single Zone Control − C0CTRL03BD1L f f f Dirty Filter Switch 30K48 f f f 2 Discharge Air Temperature Sensor Factory installed only Four Stage Control Factory installed only Fresh Air Tempering 45L78 ⊗ ⊗ ⊗ Smoke Detector − Supply LTSASDK10/36 f f f Smoke Detector − Return LTARSDK10/30 f f f Smoke Detector − Return LTARSDK30/36 C0SNSR11AE1 (Switch) x x x Supply Static Limit Switch C0SNSR12AE1− (Mounting Kit) x x x 2 Supply Static Transducer NOTE − The catalog and part numbers that appear here are for ordering field installed accessories only. f x f f f f f ⊗ f f x x f x f f f f f f f f ⊗ f f x x x f x f f f f f ⊗ f f x x ⊗ − Field Installed Accessory or Configure to Order (factory installed) f − Configure to Order (Factory Installed) X − Field Installed. 1 Two required. 2 Optional for Constant Air Volume (CAV) units (single zone or bypass zoning control). Automatically furnished with all Variable Air Volume (VAV) units. Sensor is shipped with the unit for remote field installation in the supply duct. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 11 OPTIONs / ACCESSORIES 156 180 210 240 248 300S 300H 360 L Series 77N39 87N53 87N52 87N54 85L43 90N43 70N93 x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Voltage (60HZ) − 208/230V−3 phase, 460V−3 phase or 575V−3 phase HACR Circuit Breakers Factory installed only 80 Amp − 30M39 Disconnect Switch 150 Amp − 30M40 250 Amp − 30M41 GFI Service Outlets 74M70 f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f f Item INDOOR AIR QUALITY (Co2) SENSORS Sensor − white case, CO2 display Sensor − white case, no display Sensor − black case, CO2 display Sensor − black case, no display CO2 Sensor Duct Mounting Kit Aspiration Box for duct mounting Handheld CO2 Monitor ELECTRICAL HUMIDITROL® CONDENSER REHEAT OPTION Humiditrol® Humidity Sensor Kit, Remote Mounted (required) Remote Sensor Wall Seal Plate 17M50 58L33 H x x H x x H x x f f f S x x ECONOMIZER/OUTDOOR AIR / EXHAUST Economizer LAREMD18/24 LAREMD30/36 Economizer (Order Outdoor Air Hood Below Separately) f f f Economizer Controls Differential Sensible Control Global Control Single Enthalpy Control Differential Enthalpy Control f f f f f f f f f f f f f f f f f f f f LAGEH18/30S LAGEH30H/36 f f f f LAGEDH18/24 f f f f Factory Setting Sensor field provided LTASEK03/36 LTADEK03/36 f f f f f f f f Barometric Relief Down−Flow Barometric Relief Dampers (Order Outdoor Air Hood Below Separately) Hood for Down Down−Flow Flow LAGED Horizontal Barometric Relief Dampers (Hood Furnished) LAGED18/24 f f LAGED30/36 f f f f LAGEDH30/36 Outdoor Air Dampers Damper Section (down−flow) Motorized (Order Hood Separately) Damper Section (down−flow) Manual (Order Hood Separately) f LAOADM18/24 f f f f f LAOADM30/36 f LAOAD18/24 f f f f f LAOAD30/36 Outdoor Air Hoods Outdoor Air Hood (down−flow) (Number of Filters) 16 x 25 x 1 in. f LAOAH18/24 (3) f f f f f LAOAH30/36 (5) Power Exhaust Standard Static High g Static 50% 100% 100% with VFD 100% with VFD and Bypass LAPEF18/24 LAPEF30/36 LAPEB30/36D LAPEB30/36E LAPEV30/36E LAPEV30/36F f f f f f f 1f 1f 1f 1f NOTE − The catalog and part numbers that appear here are for ordering field installed accessories only. ⊗ − Field Installed Accessory or Configure to Order (factory installed) f − Configure to Order (Factory Installed) S − Configure to Order (Factory Installed) R−22 Standard Efficiency Models Only H − Configure to Order (Factory Installed) R−22 High Efficiency Models Only X − Field Installed. 1 High Static Power Exhaust is field installed, but must be ordered at the same time as the rooftop unit so the unit can be factory configured for this option. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 12 f f 1f 1f 1f 1f 1f 1f 1f 1f OPTIONs / ACCESSORIES 300H 360 x 300S x 248 x 240 x 210 180 Item 156 L Series x x x x x x CEILING DIFFUSERS Step−Down p (O d one)) (Order RTD11−185 RTD11−275 LARTD30/36 Flush (O d one)) (Order Transitions S l and d Return R t Supply (Order one) RTD11−185S RTD11−275S LARTD30/36S FD11−185 FD11−150/180S FD11−275 FD11−275S LAFD30/36 LAFD30/36S LASRT18 LASRT18S LASRT21/24 LASRT21/24S LASRT30/36 LASRT30/36S x x x x x x x x x x x x x x ROOF CURBS − STANDARD Down−Flow 14 in. height LARMF18/36−14 x x x x x x x x 24 in. height LARMF18/36−24 x x x x x x x x 26 in. height LARMFH18/24−26 x x x x 30 in. height LARMFH30/36−30 x x x x Horizontal Slab Applications x x Rooftop Applications 37 in. height LARMFH18/24−37 41 in. height LARMFH30/36−41 x x x x x x Insulation Kits for LARMFH18/24−26 73K32 x x x x x for LARMFH18/24−37 73K34 x x x x x for LARMFH30/36−30 73K33 x x x for LARMFH30/36−41 73K35 x x x x x x x x x ROOF CURBS − CLIPLOCK 1000 Down−Flow 14 in. height g LARMF18/30S−14 x x x x x x x x LARMF30/36S−14 18 in. height g LARMF18/30S−18 x LARMF30/36S−18 24 in. height g LARMF18/30S−24 x x x x x x x LARMF30/36S−24 x x Horizontal 26 in. height LARMFH18/24S−26 x x x x x 37 in. height LARMFH18/24S−37 x x x x x 30 in. height LARMFH30/36S−30 x x x 41 in. height LARMFH30/36S−41 x x x NOTE − The catalog and part numbers that appear here are for ordering field installed accessories only. X − Field Installed L Series Packaged Gas/Electric − 13 to 30 Tons / Page 13 SPECIFICATIONS − STANDARD EFFICIENCY COOLING (CAV) General Data Nominal Tonnage Model No. Efficiency Type Blower Type Cooling g Gross Cooling Capacity − Btuh (kW) Performance P f 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant g Charge g Circuit 1 Furnished (R (R-22) 22) Circuit 2 Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (KW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure − Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condenser Motor horsepower (W) Fans F Motor rpm Total Motor watts Diameter − in. (mm) No. of blades Total Air volume − cfm (L/s) p Evaporator Net face area − sq. ft. (m2) total Coils C il Tube diameter − in. (mm) No. of rows Fins per inch (m) Drain connection − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Selection Maximum usable motor output (US Only) Motor − Drive kit 15 Ton 15 Ton LGC180S2B (R−22) Standard Constant Air Volume (CAV) 186,000 (54.5) 180,000 (52.7) 6000 (2830) 18.0 10.0 10.6 9 lbs. 0 oz. (4.08 kg) 9 lbs. 0 oz. (4.08 kg) 9 lbs. 0 oz. (4.08 kg) −−− Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (3) 56.5 (5.25) 3/8 (9.5) 1 20 (787) (4) 1/3 (249) 1075 1370 (4) 24 (610) 3 15,850 (7480) 22.3 (2.07) 3/8 (9.5) 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 865 rpm kit #2 − 685 − 865 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #4 − 945 − 1185 rpm Blowerwheelnominaldiameterxwidth Type of filter No. and size − in. (mm) Electrical characteristics Filters 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 in. (381 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 14 SPECIFICATIONS − STANDARD EFFICIENCY COOLING (CAV) General Data Nominal Tonnage Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) Cooling g P f Performance 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Circuit 1 Refrigerant g Charge g Furnished (R (R-22) 22) Circuit 2 Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (KW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure − Natural LPG/Propane Compressor Type (no.) Net face area − sq. ft. (m2) total Condenser C il Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Motor horsepower (W) Condenser F Fans Motor rpm Total Motor watts Diameter − in. (mm) No. of blades Total Air volume − cfm (L/s) Net face area − sq. ft. (m2) total Evaporator p C il Coils Tube diameter − in. (mm) No. of rows Fins per inch (m) Drain connection − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Maximum usable motor output Selection (US Only) Motor − Drive kit Blowerwheelnominaldiameterxwidth Type of filter No. and size − in. (mm) Electrical characteristics Filters 17.5 Ton 17.5 Ton LGC210S2B (R−22) Standard Constant Air Volume (CAV) 212,000 (62.1) 204,000 (59.8) 6800 (3210) 20.4 10.0 10.5 7 lbs. 0 oz. (3.18 kg) 7 lbs. 0 oz. (3.18 kg) 7 lbs. 0 oz. (3.18 kg) 7 lbs. 0 oz. (3.18 kg) Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) 56.5 (5.25) 3/8 (9.5) 1 20 (787) (4) 1/3 (249) 1075 1370 (4) 24 (610) 3 15,850 (7480) 22.3 (2.07) 3/8 (9.5) 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 1045 rpm kit #2 − 685 − 1045 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 865 rpm kit #4 − 945 − 1185 rpm 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 in. (381 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 15 SPECIFICATIONS − STANDARD EFFICIENCY COOLING (CAV) 20 and 25 Ton General Data G General l Data Nominal Tonnage 20 Ton 25 Ton Model No. LGC240S2B (R−22) LGC300S2B (R−22) Efficiency Type Standard Standard Constant Air Volume (CAV) Blower Type Type Constant Air Volume (CAV) Cooling g Gross Cooling Capacity − Btuh (kW) 243,000 (71.2) 302,000 (88.4) Performance P f 1 232,000 (67.9) 2 286,000 (83.7) Net Cooling Capacity − Btuh (kW) Total Unit Power (kW) 24.4 30.1 ARI Rated Air Flow − cfm (L/s) 8000 (3775) 9000 (4250) 1 9.5 2 9.5 EER (Btuh/Watt) 3 Integrated Part Load Value (Btuh/Watt) 9.8 9.7 Refrigerant g Charge g Circuit 1 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) Furnished (R (R-22) 22) 11 lbs. 4 oz. (5.10 kg) Circuit 2 11 lbs. 0 oz. (4.99 kg) Circuit 3 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) Circuit 4 11 lbs. 0 oz. (4.99 kg) 11 lbs. 4 oz. (5.10 kg) g g Refrigerant Charge Circuit 1 Not Available 12 lbs. 4 oz. (5.56 kg) Furnished (R-22) (R 22) Circuit 2 Not Available 12 lbs. 4 oz. (5.56 kg) with Humiditrol Option Circuit 3 Not Available 11 lbs. 4 oz. (5.10 kg) Circuit 4 Not Available 11 lbs. 4 oz. (5.10 kg) Gas Heating Heat Input Type Standard Medium High Standard Medium High Performance 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage Input − Btuh (kW) First Stage 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) Second Stage 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) Output − Btuh (kW) Second Stage 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) CSA Thermal Efficiency 80.0% 80.0% Gas Supply Connections 1 in. 1 in. Recommended Gas Supply Pressure Natural 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) LPG/Propane 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Compressor Type (no.) Scroll (4) Scroll (4) Condenser Net face area − sq. ft. (m2) total 56.5 (5.25) 56.5 (5.25) C il Coils 3/8 (9.5) Tube diameter − in. (mm) 3/8 (9.5) Number of rows 2 2 Fins per inch (m) 20 (787) 20 (787) Condenser Motor horsepower (W) (4) 1/3 (249) (4) 1/2 (373) Fans F 1075 Motor rpm 1075 Total Motor watts 1395 1800 Diameter − in. (mm) (4) 24 (610) (4) 24 (610) No. of blades 3 3 Total Air volume − cfm (L/s) 15,450 (7290) 16,000 (7550) p Evaporator Net face area − sq. ft. (m2) total 22.3 (2.07) 22.3 (2.07) Coils C il 3/8 (9.5) Tube diameter − in. (mm) 3/8 (9.5) No. of rows 3 4 Fins per inch (m) 14 (551) 14 (551) Drain connection − number and size (1) 1 in. NPT coupling (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head 4 Indoor Nominal motor output 5 hp (3.7 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 7.5 hp (5.6 kW) Blower and 10 hp (7.5 kW) 10 hp (7.5 kW) Drive Maximum usable motor output 5.75 hp (4.3 kW) 5.75 hp (4.3 kW) Selection (US Only) 8.63 hp (6.4 kW) 8.63 hp (6.4 kW) 11.5 hp (8.6 kW) 11.5 hp (8.6 kW) Motor − Drive kit 5 hp 5 hp kit #2 − 685 − 865 rpm kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #3 − 850 − 1045 rpm kit #4 945 − 1185 rpm kit #4 − 945−1185 rpm 7.5 hp 7.5 hp kit #5 − 945 − 1185 rpm kit #5 − 945 − 1185 rpm kit #6 − 1045 − 1285 rpm kit#6 − 1045−1285 rpm kit #7 − 850 − 1045 rpm kit #7 − 850 − 1045 rpm 10 hp 10 hp kit #6 − 1045−1285 rpm kit #6 − 1045 − 1285 rpm kit #8 − 1135−1365 rpm kit #8 − 1135−1365 rpm Blowerwheelnominaldiameterxwidth (2) 15 x 15 in. (381 x 381 mm) (2) 15 x 15 in. (381 x 381 mm) Filters Type of filter Disposable, pleated MERV 7 (standard) or MERV 11 (optional) No. and size − in. (mm) (6) 24 x 24 x 2 (610 x 610 x 51) Electrical characteristics 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Tested at conditions included in with ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 3 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 4 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 16 13 Ton SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General Data D t Nominal Tonnage Model No. Efficiency Type Blower Type Type Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Circuit 1 Refrigerant Charge Furnished (R-22) F i h d (R 22) Circuit 2 Circuit 3 Circuit 1 Refrigerant Charge Furnished (R-22) F i h d (R 22) Circuit 2 with Humiditrol Option Circuit 3 Gas Heating Heat Input Type Performance 13 Ton LGC156H2B (R−22) High Constant Air Volume (CAV) Cooling P f Performance Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser C il Coils Condenser F Fans Evaporator C il Coils 3 Indoor Blower and Drive Selection Net face area − sq. ft. (m2) total Tube diameter − in. (mm) − No. of rows Fins per inch (m) Motor horsepower (W) Motor rpm Total Motor watts Diameter − in. (mm) − No. of blades Total Air volume − cfm (L/s) Net face area − sq. ft. (m2) total Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condensate Drain − number and size Expansion device type Nominal motor output Maximum usable motor output (US Only) Motor − Drive kit number Blowerwheelnom. dia.xwidth−in.(mm) Type of filter No. and size − in. (mm) Electrical characteristics Filters Low 1 Stage 160,000 (46.8) 156,000 (45.7) 5100 (2405) 12.8 12.2 13.6 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 13 lbs. 8 oz. (6.12 kg) 13 lbs. 8 oz. (6.12 kg) 11 lbs. 0 oz. (4.99 kg) Standard 2 Stage Medium 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) −−− 260,000 (76.2) 360,000 (105.5) 135,000 (39.6) −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (3) 56.5 (5.25) 3/8 (9.5) − 2 20 (787) (4) 1/3 (249) 1075 1395 (4) 24 (610) − 3 15,450 (7290) 22.3 (2.07) 3/8 (9.5) − 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 2 hp (1.5 kW) 3 hp (2.2 kW) 5 hp (3.7 kW) 2.3 hp (1.7 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 2 hp kit #A − 535 − 725 rpm 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 865 rpm kit #2 − 685 − 865 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #4 − 945 − 1185 rpm (2) 15 x 15 (381 x 381) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 17 SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General Data D t Cooling Performance Nominal Tonnage Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 Furnished (R-22) F i h d (R ( 22)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 Furnished (R-410A) F i h d (R ( 410A)) Circuit 2 Circuit 3 Refrigerant Charge Circuit 1 Furnished (R-22) F i h d (R ( 22)) Circuit 2 with Humiditrol Option Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total Coils C il Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condenser Motor horsepower (W) Fans F Motor rpm Total Motor watts Diameter − in. (mm) − No. of blades Total Air volume − cfm (L/s) Evaporator Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Selection Maximum usable motor output (US Only) Motor − Drive kit number Blowerwheelnom. dia.xwidth−in.(mm) Type of filter No. and size − in. (mm) Electrical characteristics Filters 15 Ton 15 Ton LGC180H2B (R−22) LGC180H4B (R−410A) High Constant Air Volume (CAV) 188,000 (55.1) (R−22) 190,000 (55.7) (R−410A) 182,000 (53.3) (R−22 184,000 (53.9) (R−410A) 5700 (2690) 15.4 (R−22) 16.1 (R−410A) 11.8 (R−22) 11.4 (R−410A) 13.3 (R−22) 12.8 (R−410A) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) 11 lbs. 8 oz. (5.22 kg) −−− 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 14 lbs. 0 oz. (6.35 kg) 14 lbs. 0 oz. (6.35 kg) 11 lbs. 8 oz. (5.22 kg) −−− Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (3) 56.5 (5.25) 3/8 (9.5) − 2 20 (787) (4) 1/3 (249) 1075 1395 (4) 24 (610) − 3 15,450 (7290) 22.3 (2.07) 3/8 (9.5) − 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 865 rpm kit #2 − 685 − 865 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 1045 rpm kit #4 − 945 − 1185 rpm 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 (381 x 381) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 18 SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General Data Nominal Tonnage Model No. Efficiency Type Blower Type Cooling Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) Performance P f ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 Furnished (R-22) F i h d (R ( 22)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 Furnished (R-410A) ( 410A)) F i h d (R Circuit 2 Circuit 3 Refrigerant Charge Circuit 1 Furnished (R-22) F i h d (R ( 22)) Circuit 2 with Humiditrol Option Circuit 3 Circuit 4 Gas Heating Heat Input Type Performance Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) First Stage Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total Coils C il Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condenser Motor horsepower (W) F Fans Motor rpm Total Motor watts Diameter − in. (mm) − No. of blades Total Air volume − cfm (L/s) Evaporator Net face area − sq. ft. (m2) total C il Coils Tube diameter − in. (mm) − No. of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Drive Selection Maximum usable motor output (US Only) Motor − Drive kit number Blowerwheelnom. dia.xwidth−in.(mm) Type of filter No. and size − in. (mm) Electrical characteristics Filters 17.5 Ton 17.5 Ton LGC210H2B (R−22) High Constant Air Volume (CAV) 218,000 (63.9) 210,000 (61.5) 6600 (3115) 18.3 11.5 12.3 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) −−− −−− −−− 13 lbs. 0 oz. (5.90 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) Low Standard Medium High 1 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) −−− 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 135,000 (39.6) −−− −−− −−− −−− 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 1 in. 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) 56.5 (5.25) 3/8 (9.5) − 2 20 (787) (4) 1/3 (249) 1075 1395 (4) 24 (610) − 3 15,450 (7290) 22.3 (2.07) 3/8 (9.5) − 4 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 3 hp (2.2 kW) 5 hp (3.7 kW) 7.5 hp (5.6 kW) 3.45 hp (2.6 kW) 5.75 hp (4.3 kW) 8.63 hp (6.4 kW) 3 hp kit #A − 535 − 725 rpm kit #1 − 685 − 1045 rpm kit #2 − 685 − 1045 rpm 5 hp kit #2 − 685 − 865 rpm kit #3 − 850 − 865 rpm kit #4 − 945 − 1185 rpm 7.5 hp kit# 5 − 945 − 1185 rpm kit# 6 − 1045 − 1285 rpm kit# 7 − 850 − 1045 rpm (2) 15 x 15 (381 x 381) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610 x 610 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 19 SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) General Data D t Cooling Performance Nominal Tonnage (kW) Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net Gas Heating Performance Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 F i h d (R Furnished (R-22) ( 22)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 F i h d (R Furnished (R-410A) ( 410A)) Circuit 2 Circuit 3 Circuit 4 Refrigerant Charge Circuit 1 Furnished (R-22) F i h d (R ( 22)) Circuit 2 with Humiditrol Option Circuit 3 Circuit 4 Heat Input Type Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condenser Motor horsepower (W) Fans Motor rpm Total Motor watts Diameter − in. (mm) Number of blades Total Air volume − cfm (L/s) Evaporator Net face area − sq. ft. (m2) total Coils Tube diameter − in. (mm) Number of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Max. usable motor output (US Only) Di Drive Motor − Drive kit Selection Filters Blowerwheelnominaldia.xwidth Type of filter Number and size − in. (mm) Electrical characteristics 20 and 21 Ton 20 Ton 21 Ton LGA248H2B (R−22) LGA240H2B (R−22) LGA248H4B (R−410A) LGA240H4B (R−410A) High High Constant Air Volume (CAV) Constant Air Volume (CAV) 252,000 (73.8) (R−22) 257,000 (75.3) (R−22) 254,000 (74.4) (R−410A) 257,000 (75.3) (R−410A) 242,000 (70.9) (R−22) 248,000 (72.6) (R−22) 244,000 (71.5) (R−410A) 248,000 (72.6) (R−410A) 7500 (3540) 8,000 (3775) 22.0 (R−22) 23.2 (R−410A) 21.2 11.0 (R−22) 10.5 (R−410A) 11.7 11.8 (R−22) 11.5 (R−410A) 12.3 (R−22) 12.7 (R−410A) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 12 lbs. 8 oz. (5.67 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 11 lbs. 4 oz. (5.10 kg) 13 lbs. 0 oz. (5.90 kg) 12 lbs. 4 oz. (5.56 kg) --12 lbs. 4 oz. (5.56 kg) ----11 lbs. 4 oz. (5.10 kg) 11 lbs. 4 oz. (5.10 kg) --Standard Medium High Standard Medium High 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 80.0% 1 in. 1 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) Scroll (4) 56.5 (5.25) 70.6 (6.6) 3/8 (9.5) 3/8 (9.5) 2 2 20 (787) 20 (787) (4) 1/3 (249) (6) 1/3 (249) 1075 1075 1395 2500 (4) 24 (610) (6) 24 (610) 3 3 15,450 (7290) 21,500 (10,145) 22.3 (2.07) 33.3 (3.1) 3/8 (9.5) 3/8 (9.5) 4 3 14 (551) 14 (551) (1) 1 in. NPT coupling (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) 5.75 hp (4.3 kW) − 8.63 hp (6.4 kW) − 11.5 hp (8.6 kW) 5 hp 5 hp kit #2 − 685 − 865 rpm kit #1 − 660 − 810 rpm kit #3 − 850 − 1045 rpm kit #2 − 770 − 965 rpm kit #4 945 − 1185 rpm kit #6 − 560 − 710 rpm 7.5 hp kit #5 − 945 − 1185 rpm 7.5 hp kit #6 − 1045 − 1285 rpm kit #3 − 715 − 880 rpm kit #7 − 850 − 1045 rpm kit#4 − 770 − 965 rpm 10 hp kit #6 − 1045−1285 rpm 10 hp kit #8 − 1135−1365 rpm kit #3 − 715 − 880 rpm kit #5 − 850 − 1045 rpm (2) 15 x 15 in. (381 x 381 mm) (2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (6) 24 x 24 x 2 (610x610x51) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 20 21 Ton SPECIFICATIONS − HIGH EFFICIENCY COOLING (VAV) General Data D t Cooling P f Performance Gas Heating Performance Nominal Tonnage (kW) Model No. Efficiency Type Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge Circuit 1 F i h d (R Furnished (R-22) 22) Circuit 2 Circuit 3 Circuit 4 Heat Input Type 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) Btuh (kW) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) Output − Second Stage Btuh (kW) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) Indoor Blower and Drive Selection 80.0% 1 Natural 7 in. w.g. (1.7 kPa) LPG/Propane 11 in. w.g. (2.7 kPa) Compressor Type (no.) 3 High 2 Stage Btuh (kW) Gas Supply Connections Evaporator Coils Standard 2 Stage Input − First Stage Recommended Gas Supply Pressure Condenser Fans 257,000 (75.3) 248,000 (72.6) 8,000 (3775) 21.0 11.8 14.7 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) 12 lbs. 8 oz. (5.67 kg) Medium 2 Stage Input − Second Stage CSA Thermal Efficiency Condenser Coils 21 Ton LGA248H2V (R−22) High Variable Air Volume (VAV) Scroll (4) Net face area − sq. ft. (m2) total Tube diameter − in. (mm) Number of rows Fins per inch (m) Motor horsepower (W) Motor rpm Total Motor watts Diameter − in. (mm) Number of blades Total Air volume − cfm (L/s) Net face area − sq. ft. (m2) total Tube diameter − in. (mm) Number of rows Fins per inch (m) Condensate Drain − number and size Expansion device type Nominal motor output Motor − Drive kit (maximum rpm, 60hz inverter frequency setting) 70.6 (6.6) 3/8 (9.5) 2 20 (787) (6) 1/3 (249) 1075 2500 (6) 24 (610) 3 21,500 (10,145) 33.3 (3.1) 3/8 (9.5) 3 14 (551) (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) 5 hp kit #7 − 965 rpm 7.5 hp kit#8 − 965 rpm 10 hp kit #9 − 1045 rpm Filters Blowerwheelnominaldia.xwidth Type of filter Number and size − in. (mm) Electrical characteristics (2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Certified in accordance with the ULE certification program, which is based on ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 21 SPECIFICATIONS − HIGH EFFICIENCY COOLING (CAV) Nominal Tonnage (kW) General D t Data Model No. Efficiency Type Cooling Performance Blower Type Gross Cooling Capacity − Btuh (kW) 1 Net Gas Heating Performance Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) g g Refrigerant Charge Circuit 1 Furnished (R-22) F i h d (R 22) Circuit 2 Circuit 3 Circuit 4 g g Refrigerant Charge Circuit 1 Furnished (R-410A) F i h d (R 410A) Circuit 2 Circuit 3 Heat Input Type Input − Btuh (kW) First Stage Second Stage Output − Btuh (kW) Second Stage CSA Thermal Efficiency Gas Supply Connections Recommended Gas Supply Pressure Natural LPG/Propane Compressor Type (no.) Condenser Net face area − sq. ft. (m2) total Coils C il Tube diameter − in. (mm) Number of rows Fins per inch (m) Condenser Motor horsepower (W) F Fans Motor rpm Total Motor watts Diameter − in. (mm) Number of blades Total Air volume − cfm (L/s) p Evaporator Net face area − sq. ft. (m2) total Coils C il Tube diameter − in. (mm) Number of rows Fins per inch (m) Condensate Drain − number and size Expansion device type 3 Indoor Nominal motor output Blower and Bl d Max. usable motor output (US Only) Drive Motor − Drive kit Selection Blowerwheelnominaldiameterxwidth Type of filter Number and size − in. (mm) Electrical characteristics Filters 25 and 30 Ton 25 Ton 30 Ton LGC300H2B (R−22) LGA360H2B (R−22) LGA360H4B (R−410A) High High Constant Air Volume (CAV) 311,000 (91.1) Constant Air Volume (CAV) 355,000 (104.0) (R−22) 377,000 (110.5) (R−410A) 300,000 (87.9) 336,000 (98.4) (R−22) 360,000 (105.5) (R−410A) 9500 (4484) 10,500 (4955) 28.4 32.9 (R−22) 37.1 (R−410A) 11.0 10.2 (R−22) 9.7 (R−410A) 11.5 10.6 (R−22) 10.4 (R−410A) 11 lbs. 0 oz. (4.99 kg) 17 lbs. 0 oz (7.71 kg) 17 lbs. 0 oz (7.71 kg) 11 lbs. 0 oz. (4.99 kg) 11 lbs. 0 oz. (4.99 kg) 17 lbs. 0 oz (7.71 kg) 11 lbs. 0 oz. (4.99 kg) ----18 lbs. 8 oz. (8.39 kg) 18 lbs. 8 oz. (8.39 kg) ----18 lbs. 8 oz. (8.39 kg) Standard Medium High Standard Medium High 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 2 Stage 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 80.0% 80.0% 1 1 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Scroll (4) Scroll (3) 70.6 (6.6) 70.6 (6.6) 3/8 (9.5) 3/8 (9.5) 2 2 20 (787) 20 (787) (6) 1/3 (249) (6) 1/3 (249) 1075 1075 2500 2500 (6) 24 (610) (6) 24 (610) 3 3 21,500 (10,145) 21,500 (10,145) 33.3 (3.1) 33.3 (3.1) 3/8 (9.5) 3/8 (9.5) 3 3 14 (551) 14 (551) (1) 1 in. NPT coupling (1) 1 in. NPT coupling Balanced Port Thermostatic Expansion Valve, removeable power head 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) 5.75 hp (4.3 kW) − 8.63 hp (6.4 kW) − 11.5 hp (8.6 kW) 5 hp 5 hp kit #1 − 660 − 810 rpm kit #1 − 660 − 810 rpm kit #2 − 770 − 965 rpm kit #2 − 770 − 965 rpm kit #6 − 560 − 710 rpm kit #6 − 560 − 710 rpm 7.5 hp 7.5 hp kit #3 − 715 − 880 rpm kit #3 − 715 − 880 rpm kit#4 − 770 − 965 rpm kit#4 − 770 − 965 rpm 10 hp 10 hp kit #3 − 715 − 880 rpm kit #3 − 715 − 880 rpm kit #5 − 850 − 1045 rpm kit #5 − 850 − 1045 rpm (2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Tested at conditions included in with ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished by Lennox are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 22 25 and 30 Ton SPECIFICATIONS − HIGH EFFICIENCY COOLING (VAV) General D t Data Nominal Tonnage (kW) Model No. Efficiency Type Blower Type Cooling g Gross Cooling Capacity − Btuh (kW) P f Performance 1 Net Cooling Capacity − Btuh (kW) ARI Rated Air Flow − cfm (L/s) Total Unit Power (kW) 1 EER (Btuh/Watt) 2 Integrated Part Load Value (Btuh/Watt) Refrigerant Charge g g Circuit 1 F i h d (R 22) Furnished (R-22) Circuit 2 Circuit 3 Circuit 4 Gas Heating Performance Heat Input Type 25 Ton 30 Ton LGC300H2V (R−22) LGC360H2V (R−22) High High Variable Air Volume (VAV) 309,000 (90.5) 300,000 (87.9) 9000 (4245) 27.8 10.8 13.4 12 lbs. 0 oz. (5.44 kg) 12 lbs. 0 oz. (5.44 kg) 12 lbs. 0 oz. (5.44 kg) 12 lbs. 0 oz. (5.44 kg) Variable Air Volume (VAV) 348,000 (101.9) 336,000 (98.4) 10,500 (4955) 32.9 10.3 13.0 12 lbs. 0 oz (5.44 kg) 11 lbs. 0 oz (4.99 kg) 11 lbs. 0 oz (4.99 kg) 11 lbs. 0 oz (4.99 kg) Standard 2 Stage Medium 2 Stage High 2 Stage Standard 2 Stage Medium 2 Stage High 2 Stage Input − First Stage Btuh (kW) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) 169,000 (49.5) 234,000 (68.6) 312,000 (91.4) Input − Second Stage Btuh (kW) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) 260,000 (76.2) 360,000 (105.5) 480,000 (140.6) Output − Second Stage Btuh (kW) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) 208,000 (60.9) 288,000 (84.4) 384,000 (112.5) CSA Thermal Efficiency 80.0% 80.0% Gas Supply Connections 1 1 Recommended Gas Supply Pressure Natural 7 in. w.g. (1.7 kPa) 7 in. w.g. (1.7 kPa) LPG/Propane 11 in. w.g. (2.7 kPa) 11 in. w.g. (2.7 kPa) Compressor Type (no.) Scroll (4) Scroll (4) Condenser Net face area − sq. ft. (m2) total 70.6 (6.6) 70.6 (6.6) C il Coils Tube diameter − in. (mm) 3/8 (9.5) 3/8 (9.5) Number of rows 2 2 Fins per inch (m) 20 (787) 20 (787) Condenser Motor horsepower (W) (6) 1/3 (249) (6) 1/3 (249) F Fans Motor rpm 1075 1075 Total Motor watts 2500 2500 Diameter − in. (mm) (6) 24 (610) (6) 24 (610) Number of blades 3 3 Total Air volume − cfm (L/s) 21,500 (10,145) 21,500 (10,145) Evaporator p Net face area − sq. ft. (m2) total 33.3 (3.1) 33.3 (3.1) C il Coils 3/8 (9.5) Tube diameter − in. (mm) 3/8 (9.5) Number of rows 3 3 Fins per inch (m) 14 (551) 14 (551) Condensate Drain − number and size (1) 1 in. NPT coupling (1) 1 in. NPT coupling Expansion device type Balanced Port Thermostatic Expansion Valve, removeable power head 3 Indoor Nominal motor output 5 hp (3.7 kW) − 7.5 hp (5.6 kW) − 10 hp (7.5 kW) Bl d Blower and Motor − Drive kit 5 hp 5 hp Drive kit #7 − 965 rpm kit #7 − 965 rpm (maximum rpm, Selection 60hz inverter frequency setting) 7.5 hp 7.5 hp kit#8 − 965 rpm kit#8 − 965 rpm 10 hp kit #9 − 1045 rpm Blowerwheelnominaldiameterxwidth Type of filter Number and size − in. (mm) Electrical characteristics Filters 10 hp kit #9 − 1045 rpm (2) 18 x 15 in. (457 x 381 mm) Disposable, pleated MERV 7 (standard) or MERV 11 (optional) (12) 20 x 20 x 2 (508 x 508 x 51) 208/230V, 460V or 575V − 60 hertz − 3 phase NOTE − Net capacity includes evaporator blower motor heat deduction. Gross capacity does not include evaporator blower motor heat deduction. 1 Tested at conditions included in with ARI Standard 340/360; 95_F (35_C) outdoor air temperature and 80_F (27_C) db/67_F (19_C) wb entering evaporator air; minimum external duct static pressure. 2 Integrated Part Load Value tested at 80_F (27_C) outdoor air temperature. 3 Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 23 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 13 TON HIGH EFFICIENCY − LGC156H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4160 5200 6240 4160 5200 6240 4160 5200 6240 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 1965 2455 2945 1965 2455 2945 1965 2455 2945 105.6 110.2 113.9 113.2 117.3 120.4 121.4 125.7 128.7 30.9 32.3 33.4 33.2 34.4 35.3 35.6 36.8 37.7 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 4.67 .64 4.69 .69 4.71 .74 4.70 .50 4.73 .53 4.75 .55 4.75 .38 4.77 .39 4.79 .40 80_F 27_C .79 .87 .94 .61 .66 .71 .48 .51 .54 85_F 29_C .94 1.00 1.00 .74 .82 .91 .59 .63 .68 Total Cooling Capacity kBtuh 102.8 107.2 110.7 110.0 114.0 116.8 117.9 121.9 124.7 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 30.1 5.27 .64 31.4 5.29 .70 32.4 5.31 .76 32.2 5.30 .51 33.4 5.32 .53 34.2 5.34 .56 34.6 5.34 .38 35.7 5.36 .39 36.5 5.38 .40 80_F 27_C .80 .89 .96 .62 .67 .73 .49 .52 .55 85_F 29_C .96 1.00 1.00 .76 .84 .92 .59 .64 .70 Total Cooling Capacity kBtuh kW 99.6 103.8 107.2 106.4 110.1 112.8 114.1 117.8 120.4 29.2 30.4 31.4 31.2 32.3 33.1 33.4 34.5 35.3 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.95 .65 5.97 .71 5.99 .77 5.99 .51 6.00 .54 6.02 .57 6.02 .38 6.03 .39 6.05 .40 80_F 27_C .82 .90 .98 .63 .68 .75 .49 .52 .55 85_F 29_C .97 1.00 1.00 .77 .86 .94 .60 .65 .72 Total Cooling Capacity kBtuh kW 96.1 99.9 103.5 102.5 106.0 108.5 109.8 113.3 115.7 28.2 29.3 30.3 30.0 31.1 31.8 32.2 33.2 33.9 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW 75_F 80_F 85_F Input 24_C 27_C 29_C 6.71 .66 .83 .99 6.74 .73 .93 1.00 6.75 .79 .99 1.00 6.74 .52 .64 .79 6.76 .55 .70 .89 6.78 .58 .77 .97 6.78 .38 .50 .61 6.80 .40 .53 .67 6.81 .41 .56 .74 13 TON HIGH EFFICIENCY − LGC156H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4160 5200 6240 4160 5200 6240 4160 5200 6240 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 1965 2455 2945 1965 2455 2945 1965 2455 2945 150.4 156.7 161.9 160.7 166.2 170.2 172.2 177.8 181.6 44.1 45.9 47.4 47.1 48.7 49.9 50.5 52.1 53.2 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 9.03 .68 9.06 .74 9.09 .80 9.09 .53 9.12 .56 9.14 .59 9.15 .40 9.17 .41 9.19 .42 80_F 27_C .84 .92 .99 .66 .71 .77 .52 .55 .58 85_F 29_C .98 1.00 1.00 .79 .88 .96 .63 .69 .74 Total Cooling Capacity kBtuh 145.1 150.9 156.3 154.8 160.0 163.7 165.8 171.0 174.6 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 42.5 10.18 .69 44.2 10.22 .75 45.8 10.25 .82 45.4 10.24 .54 46.9 10.26 .57 48.0 10.29 .60 48.6 10.29 .40 50.1 10.32 .41 51.2 10.34 .43 80_F 27_C .85 .94 1.00 .67 .72 .79 .52 .56 .59 85_F 29_C 1.00 1.00 1.00 .81 .90 .98 .64 .70 .76 Total Cooling Capacity kBtuh kW 139.2 144.8 150.7 148.5 153.3 156.6 159.0 163.6 166.9 40.8 42.4 44.2 43.5 44.9 45.9 46.6 47.9 48.9 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 11.51 .70 11.54 .77 11.54 .84 11.54 .55 11.58 .58 11.60 .62 11.59 .41 11.64 .42 11.64 .43 80_F 27_C .87 .96 1.00 .68 .74 .81 .53 .57 .60 85_F 29_C 1.00 1.00 1.00 .83 .93 1.00 .66 .72 .79 Total Cooling Capacity kBtuh kW 132.9 138.5 144.5 141.6 145.9 149.2 151.7 155.8 158.7 38.9 40.6 42.3 41.5 42.8 43.7 44.5 45.7 46.5 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.98 .72 .90 1.00 13.01 .79 .99 1.00 13.02 .87 1.00 1.00 13.01 .56 .70 .86 13.05 .59 .77 .95 13.07 .63 .84 1.00 13.07 .41 .54 .67 13.10 .42 .58 .74 13.12 .44 .62 .81 15 TON STANDARD EFFICIENCY − LGC180S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 123.4 128.2 132.0 131.2 135.4 138.3 139.5 143.7 146.5 36.2 37.6 38.7 38.5 39.7 40.5 40.9 42.1 42.9 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.02 .66 7.13 .71 7.20 .77 7.18 .53 7.28 .55 7.34 .58 7.36 .40 7.46 .41 7.53 .42 80_F 27_C .80 .88 .94 .64 .69 .74 .51 .54 .57 85_F 29_C .94 1.00 1.00 .77 .84 .91 .62 .66 .72 Total Cooling Capacity kBtuh 120.2 124.8 128.5 127.7 131.8 134.7 136.0 140.0 142.8 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 35.2 7.72 .67 36.6 7.82 .72 37.7 7.90 .78 37.4 7.88 .53 38.6 7.98 .55 39.5 8.04 .58 39.9 8.06 .40 41.0 8.16 .41 41.9 8.22 .42 80_F 27_C .81 .89 .96 .65 .69 .75 .51 .54 .57 85_F 29_C .95 1.00 1.00 .78 .86 .93 .62 .67 .73 Total Cooling Capacity kBtuh kW 116.3 120.8 124.5 123.7 127.6 130.4 131.8 135.6 138.2 34.1 35.4 36.5 36.3 37.4 38.2 38.6 39.7 40.5 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 8.52 .68 8.62 .73 8.71 .79 8.69 .53 8.78 .56 8.85 .59 8.87 .40 8.97 .41 9.03 .42 80_F 27_C .83 .91 .97 .65 .71 .77 .52 .55 .58 85_F 29_C .97 1.00 1.00 .79 .87 .95 .63 .68 .74 Total Cooling Capacity kBtuh kW 112.1 116.5 120.2 119.2 123.0 125.6 127.1 130.8 133.1 32.9 34.1 35.2 34.9 36.0 36.8 37.2 38.3 39.0 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.45 .69 .85 .98 9.55 .75 .93 1.00 9.63 .81 .99 1.00 9.61 .54 .66 .81 9.71 .57 .72 .89 9.79 .60 .79 .96 9.82 .40 .52 .64 9.90 .41 .55 .70 9.98 .43 .59 .76 15 TON STANDARD EFFICIENCY − LGC180S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 176.3 183.2 188.8 187.6 193.5 197.7 199.8 205.6 209.5 51.7 53.7 55.3 55.0 56.7 57.9 58.6 60.3 61.4 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 12.81 .69 12.96 .74 13.09 .80 13.06 .54 13.20 .57 13.31 .60 13.34 .41 13.49 .42 13.58 .43 80_F 27_C .84 .91 .97 .67 .72 .78 .53 .56 .59 85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .75 Total Cooling Capacity kBtuh 169.9 176.6 182.2 180.7 186.4 190.4 192.6 198.2 201.8 Comp Motor kW 75_F kW Input 24_C 49.8 14.20 .70 51.8 14.35 .76 53.4 14.48 .82 53.0 14.45 .55 54.6 14.60 .58 55.8 14.72 .61 56.4 14.76 .41 58.1 14.89 .42 59.1 15.01 .43 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 24 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .85 .93 .99 .68 .73 .80 .53 .57 .60 85_F 29_C .98 1.00 1.00 .82 .90 .97 .66 .71 .77 Total Cooling Capacity kBtuh kW 163.3 169.6 175.5 173.6 178.8 182.6 185.1 190.3 193.8 47.9 49.7 51.4 50.9 52.4 53.5 54.2 55.8 56.8 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 15.75 .71 15.93 .78 16.08 .84 16.05 .56 16.19 .59 16.31 .62 16.37 .41 16.51 .43 16.61 .44 80_F 27_C .87 .95 1.00 .69 .75 .82 .54 .58 .61 85_F 29_C 1.00 1.00 1.00 .83 .92 .98 .67 .73 .79 Total Cooling Capacity kBtuh kW 156.8 162.9 169.1 166.5 171.4 174.8 177.5 182.1 185.3 46.0 47.7 49.6 48.8 50.2 51.2 52.0 53.4 54.3 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 17.52 .73 .89 1.00 17.73 .79 .97 1.00 17.91 .86 1.00 1.00 17.83 .56 .70 .85 18.01 .60 .77 .94 18.11 .64 .84 1.00 18.18 .42 .55 .68 18.36 .43 .59 .74 18.45 .44 .63 .81 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 15 TON HIGH EFFICIENCY − LGC180H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 128.6 133.8 137.6 137.0 141.7 145.1 146.2 150.9 154.1 37.7 39.2 40.3 40.2 41.5 42.5 42.8 44.2 45.2 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.78 .66 5.82 .71 5.85 .76 5.84 .52 5.87 .55 5.91 .57 5.91 .40 5.95 .41 5.98 .42 80_F 27_C .80 .87 .93 .64 .68 .73 .51 .53 .56 85_F 29_C .93 .99 1.00 .76 .83 .90 .61 .66 .71 Total Cooling Capacity kBtuh 125.2 130.0 133.9 133.3 137.7 140.9 142.0 146.5 149.6 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 36.7 6.47 .67 38.1 6.52 .72 39.2 6.54 .77 39.1 6.53 .53 40.4 6.58 .55 41.3 6.61 .58 41.6 6.61 .40 42.9 6.65 .41 43.8 6.68 .42 80_F 27_C .81 .88 .95 .64 .69 .74 .51 .54 .57 85_F 29_C .94 1.00 1.00 .77 .84 .91 .62 .67 .72 Total Cooling Capacity kBtuh kW 121.4 126.1 129.9 129.1 133.3 136.3 137.7 141.8 144.8 35.6 37.0 38.1 37.8 39.1 39.9 40.4 41.6 42.4 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.29 .67 7.32 .73 7.36 .78 7.35 .53 7.39 .56 7.41 .59 7.42 .40 7.46 .41 7.48 .42 80_F 27_C .82 .90 .96 .65 .70 .76 .51 .54 .57 85_F 29_C .96 1.00 1.00 .78 .86 .93 .63 .68 .73 Total Cooling Capacity kBtuh kW 117.2 121.8 125.4 124.7 128.6 131.4 132.9 136.8 139.6 34.3 35.7 36.8 36.5 37.7 38.5 38.9 40.1 40.9 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.22 .68 .84 .97 8.26 .74 .91 1.00 8.29 .80 .98 1.00 8.30 .54 .66 .80 8.32 .57 .72 .88 8.35 .60 .78 .95 8.37 .40 .52 .64 8.40 .41 .55 .69 8.43 .42 .58 .75 15 TON HIGH EFFICIENCY − LGC180H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 177.6 184.4 189.9 188.9 195.0 199.5 201.4 207.6 211.8 52.0 54.0 55.7 55.4 57.1 58.5 59.0 60.8 62.1 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 10.86 .69 10.92 .73 10.96 .79 10.96 .54 11.02 .57 11.05 .60 11.06 .41 11.13 .42 11.17 .43 80_F 27_C .82 .90 .96 .66 .71 .76 .52 .55 .58 85_F 29_C .96 1.00 1.00 .79 .86 .93 .64 .69 .74 Total Cooling Capacity kBtuh 171.5 178.1 183.6 182.3 188.1 192.3 194.5 200.2 204.1 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 50.3 12.26 .69 52.2 12.31 .75 53.8 12.36 .80 53.4 12.36 .54 55.1 12.40 .57 56.4 12.46 .60 57.0 12.47 .41 58.7 12.52 .42 59.8 12.56 .43 80_F 27_C .84 .92 .98 .67 .72 .78 .53 .56 .59 85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .76 Total Cooling Capacity kBtuh kW 165.1 171.4 176.9 175.4 180.9 184.8 187.0 192.5 196.0 48.4 50.2 51.8 51.4 53.0 54.2 54.8 56.4 57.4 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 13.86 .70 13.91 .76 13.97 .82 13.97 .55 14.00 .58 14.06 .61 14.09 .41 14.13 .42 14.19 .44 80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .60 85_F 29_C .99 1.00 1.00 .82 .90 .97 .66 .71 .78 Total Cooling Capacity kBtuh kW 158.3 164.3 170.3 168.2 173.2 176.8 179.4 184.4 187.6 46.4 48.2 49.9 49.3 50.8 51.8 52.6 54.0 55.0 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 15.67 .72 .88 1.00 15.75 .78 .96 1.00 15.78 .84 1.00 1.00 15.78 .56 .69 .84 15.84 .59 .76 .92 15.90 .63 .82 .99 15.91 .41 .54 .67 15.96 .43 .58 .73 16.01 .44 .62 .80 15 TON HIGH EFFICIENCY − LGC180H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 131.6 137.0 141.2 140.4 145.5 149.0 149.8 155.0 158.6 38.6 40.2 41.4 41.1 42.6 43.7 43.9 45.4 46.5 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.75 .68 5.77 .72 5.79 .77 5.79 .54 5.81 .56 5.83 .59 5.83 .42 5.85 .42 5.87 .43 80_F 27_C .80 .86 .92 .65 .70 .74 .52 .55 .57 85_F 29_C .92 .98 1.00 .77 .83 .89 .63 .67 .72 Total Cooling Capacity kBtuh 126.8 131.9 135.9 135.2 139.9 143.2 144.3 149.1 152.3 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 37.2 6.57 .69 38.7 6.61 .73 39.8 6.63 .78 39.6 6.62 .55 41.0 6.65 .57 42.0 6.68 .60 42.3 6.68 .42 43.7 6.71 .42 44.6 6.74 .43 80_F 27_C .82 .88 .94 .66 .71 .76 .53 .55 .58 85_F 29_C .94 .99 1.00 .78 .85 .91 .64 .68 .73 Total Cooling Capacity kBtuh kW 121.7 126.6 130.5 129.7 134.1 137.2 138.5 142.8 145.8 35.7 37.1 38.2 38.0 39.3 40.2 40.6 41.9 42.7 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.51 .70 7.54 .75 7.56 .80 7.56 .55 7.60 .58 7.62 .61 7.62 .42 7.66 .43 7.69 .44 80_F 27_C .83 .90 .96 .67 .72 .78 .53 .56 .59 85_F 29_C .95 1.00 1.00 .80 .87 .93 .65 .70 .75 Total Cooling Capacity kBtuh kW 116.3 120.9 124.7 123.9 127.9 130.8 132.2 136.2 139.0 34.1 35.4 36.5 36.3 37.5 38.3 38.7 39.9 40.7 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.57 .71 .85 .97 8.60 .76 .92 1.00 8.63 .82 .98 1.00 8.63 .56 .69 .82 8.66 .59 .74 .89 8.68 .62 .79 .95 8.69 .42 .54 .66 8.73 .43 .57 .72 8.75 .44 .61 .77 15 TON HIGH EFFICIENCY − LGC180H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 182.2 189.5 195.4 194.2 200.8 205.4 207.3 213.8 218.3 53.4 55.5 57.3 56.9 58.8 60.2 60.8 62.7 64.0 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 11.30 .70 11.35 .75 11.38 .80 11.38 .55 11.44 .58 11.47 .61 11.47 .42 11.53 .43 11.58 .44 80_F 27_C .83 .90 .96 .67 .72 .77 .53 .56 .59 85_F 29_C .95 1.00 1.00 .80 .86 .93 .65 .70 .75 Total Cooling Capacity kBtuh 174.1 181.0 186.7 185.5 191.5 195.9 197.9 203.9 208.1 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 51.0 12.89 .71 53.0 12.94 .76 54.7 12.98 .81 54.4 12.99 .56 56.1 13.03 .59 57.4 13.06 .62 58.0 13.08 .42 59.8 13.14 .43 61.0 13.17 .44 80_F 27_C .85 .92 .98 .68 .74 .79 .54 .57 .61 85_F 29_C .97 1.00 1.00 .81 .89 .95 .66 .71 .77 Total Cooling Capacity kBtuh kW 165.4 171.8 177.5 176.1 181.6 185.5 188.0 193.4 196.9 48.5 50.3 52.0 51.6 53.2 54.4 55.1 56.7 57.7 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 14.68 .73 14.72 .78 14.76 .84 14.76 .57 14.81 .60 14.86 .63 14.88 .42 14.91 .43 14.97 .45 80_F 27_C .87 .94 .99 .70 .76 .82 .55 .58 .62 85_F 29_C .99 1.00 1.00 .83 .91 .97 .67 .73 .79 Total Cooling Capacity kBtuh kW 155.8 161.9 168.3 165.8 170.6 174.4 177.1 181.8 185.1 45.7 47.4 49.3 48.6 50.0 51.1 51.9 53.3 54.2 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.68 .74 .90 1.00 16.74 .81 .97 1.00 16.75 .87 1.00 1.00 16.76 .58 .72 .86 16.82 .61 .78 .94 16.84 .65 .84 .99 16.85 .43 .56 .69 16.91 .44 .60 .76 16.93 .45 .64 .82 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 25 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 17.5 TON STANDARD EFFICIENCY − LGC210S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 5600 7000 8400 5600 7000 8400 5600 7000 8400 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965 104.0 108.0 111.0 110.4 113.8 116.4 117.4 120.8 123.2 30.5 31.7 32.5 32.4 33.4 34.1 34.4 35.4 36.1 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.70 .64 5.80 .69 5.86 .75 5.86 .50 5.92 .53 6.00 .56 6.02 .38 6.10 .39 6.16 .40 80_F 27_C .79 .87 .95 .62 .66 .72 .49 .52 .55 85_F 29_C .94 1.00 1.00 .75 .84 .91 .60 .64 .70 Total Cooling Capacity kBtuh 100.8 104.4 107.6 107.0 110.2 112.4 113.8 116.8 119.0 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 29.5 6.34 .65 30.6 6.44 .70 31.5 6.50 .76 31.4 6.48 .51 32.3 6.58 .54 32.9 6.62 .56 33.4 6.66 .38 34.2 6.74 .39 34.9 6.80 .40 80_F 27_C .81 .89 .96 .63 .67 .74 .49 .52 .56 85_F 29_C .96 1.00 1.00 .77 .86 .93 .60 .65 .71 Total Cooling Capacity kBtuh kW 97.2 100.8 104.0 103.2 106.2 108.4 109.8 112.6 114.8 28.5 29.5 30.5 30.2 31.1 31.8 32.2 33.0 33.6 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.06 .66 7.14 .72 7.22 .78 7.20 .51 7.30 .54 7.34 .57 7.38 .39 7.48 .39 7.54 .41 80_F 27_C .82 .91 .98 .63 .69 .76 .50 .53 .56 85_F 29_C .98 1.00 1.00 .78 .88 .95 .61 .67 .73 Total Cooling Capacity kBtuh kW 93.6 97.0 100.2 99.2 102.0 104.0 105.4 108.2 110.2 27.4 28.4 29.4 29.1 29.9 30.5 30.9 31.7 32.3 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.88 .67 .84 .99 7.96 .74 .93 1.00 8.06 .80 .99 1.00 8.04 .52 .65 .80 8.12 .55 .71 .90 8.18 .58 .78 .97 8.22 .39 .51 .63 8.30 .40 .54 .68 8.38 .41 .57 .76 17.5 TON STANDARD EFFICIENCY − LGC210S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 5600 7000 8400 5600 7000 8400 5600 7000 8400 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965 202.0 209.4 215.8 214.4 220.6 225.2 228.0 234.0 238.4 59.2 61.4 63.2 62.8 64.7 66.0 66.8 68.6 69.9 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 14.24 .69 14.40 .74 14.56 .80 14.52 .54 14.72 .57 14.82 .60 14.88 .40 15.08 .42 15.20 .43 80_F 27_C .84 .92 .98 .67 .72 .78 .52 .56 .59 85_F 29_C .98 1.00 1.00 .80 .89 .96 .64 .70 .76 Total Cooling Capacity kBtuh 194.4 201.4 208.0 206.0 212.0 216.2 219.2 224.8 229.0 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 57.0 15.88 .70 59.0 16.06 .76 61.0 16.26 .82 60.4 16.22 .55 62.1 16.38 .58 63.4 16.50 .61 64.2 16.58 .41 65.9 16.74 .42 67.1 16.90 .43 80_F 27_C .86 .94 1.00 .68 .73 .80 .53 .57 .60 85_F 29_C .99 1.00 1.00 .82 .91 .98 .66 .71 .78 Total Cooling Capacity kBtuh kW 186.2 193.2 199.8 197.0 202.8 206.6 209.8 215.2 218.6 54.6 56.6 58.6 57.7 59.4 60.5 61.5 63.1 64.1 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 17.76 .72 17.96 .78 18.16 .85 18.10 .55 18.28 .59 18.40 .62 18.48 .41 18.64 .42 18.80 .44 80_F 27_C .88 .96 1.00 .69 .75 .82 .54 .58 .62 85_F 29_C 1.00 1.00 1.00 .84 .93 .99 .67 .73 .80 Total Cooling Capacity kBtuh kW 177.4 184.4 191.2 187.6 192.6 196.6 199.6 204.6 207.6 52.0 54.0 56.0 55.0 56.4 57.6 58.5 60.0 60.8 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 19.92 .73 .91 1.00 20.12 .80 .99 1.00 20.34 .87 1.00 1.00 20.24 .56 .71 .87 20.46 .60 .78 .96 20.54 .64 .85 1.00 20.66 .41 .55 .69 20.82 .43 .59 .76 20.94 .44 .63 .83 17.5 TON HIGH EFFICIENCY − LGC210H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 5600 7000 8400 5600 7000 8400 5600 7000 8400 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965 109.2 114.0 117.6 116.6 120.8 123.8 124.8 129.0 131.8 32.0 33.4 34.5 34.2 35.4 36.3 36.6 37.8 38.6 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 4.94 .65 4.98 .70 5.00 .76 5.00 .51 5.02 .54 5.06 .57 5.06 .39 5.10 .40 5.12 .41 80_F 27_C .80 .89 .97 .63 .67 .74 .49 .52 .56 85_F 29_C .95 1.00 1.00 .76 .85 .93 .60 .65 .71 Total Cooling Capacity kBtuh 106.2 110.6 114.2 113.2 117.0 119.8 121.0 124.8 127.4 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 31.1 5.58 .66 32.4 5.60 .72 33.5 5.64 .78 33.2 5.62 .51 34.3 5.66 .55 35.1 5.68 .58 35.5 5.70 .39 36.6 5.72 .40 37.3 5.76 .41 80_F 27_C .81 .91 .98 .63 .69 .75 .50 .53 .56 85_F 29_C .97 1.00 1.00 .77 .86 .95 .61 .66 .72 Total Cooling Capacity kBtuh kW 102.6 106.8 110.6 109.4 113.0 115.6 116.8 120.4 122.8 30.1 31.3 32.4 32.1 33.1 33.9 34.2 35.3 36.0 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 6.28 .67 6.32 .73 6.34 .80 6.34 .52 6.38 .55 6.40 .58 6.40 .39 6.44 .40 6.46 .41 80_F 27_C .83 .93 1.00 .64 .70 .77 .50 .54 .57 85_F 29_C .98 1.00 1.00 .79 .89 .97 .62 .67 .74 Total Cooling Capacity kBtuh kW 98.8 102.8 107.0 105.2 108.6 111.0 112.4 115.6 117.8 29.0 30.1 31.4 30.8 31.8 32.5 32.9 33.9 34.5 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW 75_F 80_F 85_F Input 24_C 27_C 29_C 7.08 .68 .85 1.00 7.12 .75 .95 1.00 7.14 .82 1.00 1.00 7.14 .53 .65 .81 7.18 .56 .72 .91 7.20 .60 .79 .99 7.20 .39 .51 .63 7.24 .40 .55 .69 7.26 .42 .59 .77 17.5 TON HIGH EFFICIENCY − LGC210H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 5600 7000 8400 5600 7000 8400 5600 7000 8400 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965 207.7 216.4 223.8 221.4 228.9 234.2 236.6 244.1 249.0 60.9 63.4 65.6 64.9 67.1 68.6 69.3 71.5 73.0 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 12.74 .70 12.82 .76 12.86 .82 12.84 .55 12.92 .58 12.96 .62 12.98 .41 13.04 .42 13.08 .44 80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .60 85_F 29_C .98 1.00 1.00 .81 .90 .97 .65 .71 .77 Total Cooling Capacity kBtuh 200.3 208.4 216.4 213.2 220.1 225.2 228.0 234.5 239.0 Comp Motor kW 75_F kW Input 24_C 58.7 14.36 .71 61.1 14.44 .78 63.4 14.50 .84 62.5 14.48 .56 64.5 14.56 .59 66.0 14.60 .63 66.8 14.60 .41 68.7 14.68 .43 70.0 14.72 .44 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 26 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .87 .95 1.00 .69 .75 .81 .54 .58 .62 85_F 29_C 1.00 1.00 1.00 .83 .92 .99 .66 .73 .79 Total Cooling Capacity kBtuh kW 192.0 199.9 208.4 204.3 210.8 215.3 218.4 224.4 228.6 56.3 58.6 61.1 59.9 61.8 63.1 64.0 65.8 67.0 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 16.20 .73 16.30 .79 16.34 .86 16.32 .56 16.38 .60 16.42 .64 16.46 .42 16.50 .43 16.54 .45 80_F 27_C .89 .97 1.00 .70 .77 .84 .55 .59 .63 85_F 29_C 1.00 1.00 1.00 .85 .94 1.00 .68 .74 .81 Total Cooling Capacity kBtuh kW 183.1 191.2 199.6 194.7 200.8 205.2 208.0 213.7 217.6 53.7 56.0 58.5 57.1 58.8 60.1 61.0 62.6 63.8 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 18.30 .74 .91 1.00 18.36 .82 .99 1.00 18.44 .89 1.00 1.00 18.42 .57 .72 .87 18.48 .61 .79 .97 18.52 .65 .86 1.00 18.56 .42 .56 .69 18.60 .44 .60 .76 18.64 .45 .65 .84 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 20 TON STANDARD EFFICIENCY − LGC240S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 118.8 123.0 126.4 126.0 129.8 132.4 133.8 137.4 140.0 34.8 36.0 37.0 36.9 38.0 38.8 39.2 40.3 41.0 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 6.72 .60 6.80 .65 6.86 .71 6.86 .48 6.92 .50 6.98 .52 7.02 .36 7.08 .37 7.14 .38 80_F 27_C .76 .85 .93 .58 .62 .68 .46 .49 .51 85_F 29_C .92 1.00 1.00 .72 .81 .89 .56 .61 .66 Total Cooling Capacity kBtuh 115.8 120.0 123.4 122.8 126.4 129.0 130.6 134.2 136.6 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 33.9 7.38 .61 35.2 7.46 .66 36.2 7.54 .72 36.0 7.52 .48 37.0 7.58 .50 37.8 7.64 .53 38.3 7.66 .36 39.3 7.74 .37 40.0 7.80 .38 80_F 27_C .77 .86 .94 .59 .63 .70 .46 .49 .52 85_F 29_C .94 1.00 1.00 .73 .82 .91 .56 .61 .67 Total Cooling Capacity kBtuh kW 112.0 116.2 119.6 119.0 122.6 125.0 126.6 130.0 132.4 32.8 34.1 35.1 34.9 35.9 36.6 37.1 38.1 38.8 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 8.14 .62 8.24 .67 8.30 .74 8.28 .48 8.36 .51 8.42 .54 8.44 .36 8.52 .37 8.56 .38 80_F 27_C .79 .89 .96 .59 .64 .72 .47 .50 .53 85_F 29_C .96 1.00 1.00 .74 .84 .93 .57 .62 .69 Total Cooling Capacity kBtuh kW 108.0 112.2 115.6 114.6 118.0 120.4 122.2 125.4 127.6 31.7 32.9 33.9 33.6 34.6 35.3 35.8 36.8 37.4 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.02 .62 .81 .98 9.12 .69 .91 1.00 9.18 .76 .98 1.00 9.16 .49 .60 .76 9.26 .51 .66 .87 9.30 .54 .74 .95 9.32 .36 .47 .58 9.40 .37 .50 .63 9.46 .39 .53 .71 20 TON STANDARD EFFICIENCY − LGC240S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 230.6 239.2 246.2 245.0 252.2 257.4 260.6 267.6 272.6 67.6 70.1 72.2 71.8 73.9 75.4 76.4 78.4 79.9 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 16.66 .69 16.86 .74 16.98 .80 16.94 .54 17.10 .57 17.24 .60 17.28 .41 17.44 .42 17.52 .43 80_F 27_C .85 .93 1.00 .67 .72 .78 .52 .56 .59 85_F 29_C .99 1.00 1.00 .81 .89 .97 .64 .70 .75 Total Cooling Capacity kBtuh 222.4 231.0 238.0 236.0 243.0 248.0 251.6 258.2 262.8 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 65.2 18.46 .70 67.7 18.66 .76 69.8 18.80 .82 69.2 18.76 .55 71.2 18.94 .58 72.7 19.04 .61 73.7 19.08 .41 75.7 19.24 .42 77.0 19.36 .43 80_F 27_C .86 .95 1.00 .68 .73 .80 .53 .57 .60 85_F 29_C 1.00 1.00 1.00 .82 .91 .99 .65 .71 .77 Total Cooling Capacity kBtuh kW 213.8 222.0 229.4 227.0 233.4 238.4 241.8 248.0 252.4 62.7 65.1 67.2 66.5 68.4 69.9 70.9 72.7 74.0 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 20.54 .71 20.70 .78 20.88 .84 20.82 .55 21.00 .59 21.12 .62 21.18 .41 21.36 .42 21.46 .44 80_F 27_C .88 .97 1.00 .69 .75 .82 .54 .58 .61 85_F 29_C 1.00 1.00 1.00 .84 .94 1.00 .67 .73 .79 Total Cooling Capacity kBtuh kW 205.4 213.4 220.8 217.6 223.8 228.4 232.0 237.8 241.8 60.2 62.5 64.7 63.8 65.6 66.9 68.0 69.7 70.9 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 22.84 .73 .91 1.00 23.02 .80 .99 1.00 23.24 .87 1.00 1.00 23.18 .56 .70 .87 23.34 .60 .77 .96 23.46 .63 .84 1.00 23.58 .41 .55 .68 23.72 .43 .58 .74 23.84 .44 .62 .82 20 TON HIGH EFFICIENCY − LGA240H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 126.6 131.6 135.8 134.6 139.2 142.4 143.6 148.0 151.2 37.1 38.6 39.8 39.4 40.8 41.7 42.1 43.4 44.3 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.26 .63 .78 .94 6.32 .68 .87 1.00 6.36 .74 .95 1.00 6.34 .50 .61 .74 6.40 .52 .65 .83 6.42 .55 .72 .91 6.44 .38 .48 .59 6.48 .39 .51 .63 6.52 .40 .54 .69 75_F (24_C) Total Cooling Capacity kBtuh kW 122.8 127.8 131.8 130.6 134.8 138.0 139.4 143.4 146.4 36.0 37.5 38.6 38.3 39.5 40.4 40.9 42.0 42.9 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.04 .64 .80 .95 7.08 .69 .89 1.00 7.14 .76 .97 1.00 7.12 .50 .62 .75 7.18 .53 .67 .85 7.20 .56 .73 .93 7.22 .38 .49 .59 7.28 .39 .52 .64 7.30 .40 .55 .70 85_F (29_C) Total Cooling Capacity kBtuh kW 118.8 123.6 127.6 126.4 130.4 133.4 134.8 138.6 141.4 34.8 36.2 37.4 37.0 38.2 39.1 39.5 40.6 41.4 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.94 .65 .81 .97 8.00 .71 .91 1.00 8.04 .78 .98 1.00 8.02 .51 .62 .77 8.08 .54 .68 .87 8.12 .57 .75 .95 8.14 .38 .49 .60 8.18 .39 .52 .66 8.24 .40 .56 .72 95_F (35_C) Total Cooling Capacity kBtuh kW 114.8 119.2 123.4 121.8 125.6 128.4 129.8 133.6 136.0 33.6 34.9 36.2 35.7 36.8 37.6 38.0 39.2 39.9 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.98 .66 .83 .99 9.04 .73 .93 1.00 9.10 .80 1.00 1.00 9.08 .51 .63 .79 9.13 .54 .70 .89 9.18 .58 .77 .97 9.20 .38 .50 .61 9.24 .39 .53 .67 9.28 .41 .57 .74 20 TON HIGH EFFICIENCY − LGA240H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 238.4 248.0 256.0 253.4 261.6 267.5 270.3 278.1 283.6 69.9 72.7 75.0 74.3 76.7 78.4 79.2 81.5 83.1 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 15.72 .70 .85 .99 15.84 .75 .93 1.00 15.92 .81 1.00 1.00 15.89 .55 .67 .81 16.00 .58 .73 .89 16.08 .61 .79 .97 16.12 .41 .53 .65 16.20 .42 .56 .70 16.32 .43 .60 .76 95_F (35_C) Total Cooling Capacity kBtuh kW 230.2 239.2 247.6 244.3 252.0 257.6 260.5 268.0 272.9 67.5 70.1 72.6 71.6 73.9 75.5 76.3 78.5 80.0 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 17.80 .71 .86 1.00 17.90 .77 .95 1.00 18.02 .83 1.00 1.00 17.98 .55 .68 .82 18.09 .58 .74 .91 18.18 .62 .81 .99 18.22 .41 .53 .66 18.30 .42 .57 .72 18.39 .44 .61 .78 105_F (41_C) Total Cooling Capacity kBtuh kW 221.2 230.0 238.6 234.8 241.9 247.1 250.4 257.2 261.7 64.8 67.4 69.9 68.8 70.9 72.4 73.4 75.4 76.7 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.16 .72 .88 1.00 20.28 .78 .97 1.00 20.40 .85 1.00 1.00 20.32 .56 .69 .84 20.48 .59 .76 .94 20.56 .63 .83 1.00 20.60 .41 .54 .67 20.72 .43 .58 .73 20.79 .44 .62 .81 115_F (46_C) Total Cooling Capacity kBtuh kW 211.5 220.2 229.4 224.4 231.0 236.0 239.5 245.7 249.9 62.0 64.5 67.2 65.8 67.7 69.2 70.2 72.0 73.2 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 22.82 .73 .91 1.00 22.96 .81 .99 1.00 23.09 .88 1.00 1.00 23.02 .57 .71 .87 23.18 .60 .78 .96 23.24 .64 .85 1.00 23.28 .42 .55 .69 23.40 .43 .59 .75 23.48 .45 .64 .83 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 27 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 20 TON HIGH EFFICIENCY − LGA240H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 133.0 138.4 142.6 141.4 146.4 149.8 150.8 155.6 159.0 39.0 40.6 41.8 41.4 42.9 43.9 44.2 45.6 46.6 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 6.30 .67 6.36 .72 6.38 .77 6.36 .53 6.42 .56 6.46 .58 6.46 .41 6.50 .41 6.54 .42 80_F 27_C .80 .87 .94 .65 .69 .74 .51 .54 .57 85_F 29_C .93 1.00 1.00 .76 .84 .91 .62 .67 .72 Total Cooling Capacity kBtuh 128.0 133.2 137.2 136.0 140.6 144.0 145.0 149.4 152.6 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 37.5 7.18 .68 39.0 7.24 .73 40.2 7.28 .78 39.9 7.26 .54 41.2 7.32 .56 42.2 7.36 .59 42.5 7.36 .41 43.8 7.42 .42 44.7 7.46 .43 80_F 27_C .82 .89 .95 .66 .70 .76 .52 .55 .58 85_F 29_C .95 1.00 1.00 .78 .86 .93 .63 .68 .74 Total Cooling Capacity kBtuh kW 122.6 127.6 131.6 130.4 134.6 137.6 139.0 143.0 145.8 35.9 37.4 38.6 38.2 39.4 40.3 40.7 41.9 42.7 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 8.20 .69 8.24 .75 8.30 .80 8.28 .54 8.34 .57 8.38 .60 8.38 .41 8.46 .42 8.48 .43 80_F 27_C .83 .91 .97 .67 .72 .78 .52 .56 .59 85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .76 Total Cooling Capacity kBtuh kW 117.0 121.6 125.6 124.2 128.2 131.0 132.4 136.2 138.8 34.3 35.6 36.8 36.4 37.6 38.4 38.8 39.9 40.7 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.34 .70 .85 .98 9.40 .77 .93 1.00 9.44 .83 .99 1.00 9.42 .55 .68 .82 9.48 .58 .74 .90 9.52 .62 .80 .97 9.54 .41 .53 .66 9.58 .42 .57 .71 9.62 .44 .61 .78 20 TON HIGH EFFICIENCY − LGA240H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 245.5 255.5 263.5 261.1 269.5 275.6 278.3 286.4 292.0 71.9 74.9 77.2 76.5 79.0 80.8 81.6 83.9 85.6 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 16.40 .69 16.48 .74 16.60 .80 16.56 .54 16.68 .57 16.76 .60 16.76 .41 16.92 .42 16.96 .43 80_F 27_C .83 .91 .97 .67 .72 .78 .52 .56 .59 85_F 29_C .96 1.00 1.00 .79 .87 .95 .64 .70 .75 Total Cooling Capacity kBtuh 234.3 243.5 251.6 248.7 256.7 262.4 265.1 272.8 277.9 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 68.7 18.68 .70 71.4 18.79 .76 73.7 18.88 .82 72.9 18.84 .55 75.2 18.96 .58 76.9 19.04 .62 77.7 19.08 .41 79.9 19.16 .42 81.4 19.25 .44 80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .61 85_F 29_C .98 1.00 1.00 .81 .90 .97 .66 .71 .78 Total Cooling Capacity kBtuh kW 221.9 230.7 239.5 235.5 242.4 248.0 251.2 257.6 262.4 65.0 67.6 70.2 69.0 71.0 72.7 73.6 75.5 76.9 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 21.20 .72 21.32 .78 21.44 .85 21.40 .56 21.52 .59 21.56 .63 21.59 .41 21.72 .43 21.76 .44 80_F 27_C .88 .96 1.00 .70 .76 .83 .54 .58 .62 85_F 29_C 1.00 1.00 1.00 .84 .93 .99 .67 .73 .80 Total Cooling Capacity kBtuh kW 208.4 217.1 226.3 221.1 227.6 232.4 236.0 241.7 246.0 61.1 63.6 66.3 64.8 66.7 68.1 69.2 70.8 72.1 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 24.08 .74 .91 1.00 24.16 .81 .99 1.00 24.28 .88 1.00 1.00 24.24 .57 .72 .87 24.32 .61 .79 .96 24.40 .65 .86 1.00 24.43 .42 .56 .69 24.52 .43 .60 .76 24.59 .45 .64 .84 21 TON HIGH EFFICIENCY − LGA248H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6720 8400 10080 6720 8400 10080 6720 8400 10080 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760 123.2 128.1 132.0 131.1 135.6 138.9 139.9 144.4 147.5 36.1 37.5 38.7 38.4 39.7 40.7 41.0 42.3 43.2 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.56 .58 5.59 .63 5.63 .70 5.61 .46 5.65 .48 5.68 .50 5.69 .35 5.72 .35 5.75 .36 80_F 27_C .74 .84 .93 .56 .60 .66 .44 .47 .49 85_F 29_C .92 1.00 1.00 .69 .79 .89 .54 .58 .63 Total Cooling Capacity kBtuh 119.8 124.6 128.3 127.5 131.7 134.8 136.0 140.3 143.1 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 35.1 6.23 .59 36.5 6.25 .64 37.6 6.29 .71 37.4 6.29 .46 38.6 6.32 .48 39.5 6.34 .51 39.9 6.35 .35 41.1 6.39 .36 41.9 6.41 .37 80_F 27_C .76 .86 .95 .56 .61 .68 .45 .47 .50 85_F 29_C .94 1.00 1.00 .71 .81 .91 .54 .59 .65 Total Cooling Capacity kBtuh kW 116.1 120.7 124.6 123.6 127.5 130.4 131.7 135.8 138.5 34.0 35.4 36.5 36.2 37.4 38.2 38.6 39.8 40.6 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.00 .59 7.03 .66 7.06 .73 7.06 .46 7.09 .49 7.12 .52 7.13 .35 7.15 .36 7.19 .37 80_F 27_C .77 .88 .97 .57 .62 .70 .45 .48 .51 85_F 29_C .96 1.00 1.00 .72 .83 .93 .55 .60 .67 Total Cooling Capacity kBtuh kW 112.2 116.5 120.5 119.3 123.0 125.7 127.3 130.9 133.4 32.9 34.1 35.3 35.0 36.0 36.8 37.3 38.4 39.1 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.89 .60 .79 .98 7.93 .67 .91 1.00 7.95 .75 .99 1.00 7.95 .47 .58 .74 7.99 .50 .64 .86 8.01 .52 .72 .96 8.02 .35 .45 .56 8.06 .36 .49 .61 8.09 .37 .52 .69 21 TON HIGH EFFICIENCY − LGA248H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6720 8400 10080 6720 8400 10080 6720 8400 10080 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760 244.2 253.6 261.8 259.8 268.2 274.0 277.0 285.4 291.0 71.6 74.3 76.7 76.1 78.6 80.3 81.2 83.6 85.3 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 14.08 .69 14.14 .75 14.22 .80 14.20 .54 14.26 .57 14.34 .61 14.34 .41 14.42 .42 14.46 .43 80_F 27_C .84 .92 .98 .67 .72 .78 .53 .56 .60 85_F 29_C .97 1.00 1.00 .80 .88 .95 .64 .70 .76 Total Cooling Capacity kBtuh 235.8 245.0 253.2 250.8 258.8 264.4 267.4 275.2 280.4 Comp Motor kW 75_F kW Input 24_C 69.1 15.88 .70 71.8 15.94 .76 74.2 16.02 .82 73.5 16.00 .55 75.8 16.06 .58 77.5 16.12 .62 78.4 16.14 .41 80.7 16.22 .42 82.2 16.26 .44 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 28 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .85 .93 .99 .68 .74 .80 .53 .57 .60 85_F 29_C .99 1.00 1.00 .81 .90 .97 .65 .71 .77 Total Cooling Capacity kBtuh kW 227.2 236.0 244.4 241.4 248.8 254.0 257.4 264.6 269.4 66.6 69.2 71.6 70.7 72.9 74.4 75.4 77.5 79.0 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 17.94 .71 18.02 .78 18.06 .84 18.06 .56 18.14 .59 18.20 .63 18.22 .41 18.28 .43 18.34 .44 80_F 27_C .87 .95 1.00 .69 .75 .82 .54 .58 .62 85_F 29_C 1.00 1.00 1.00 .83 .92 .99 .67 .73 .79 Total Cooling Capacity kBtuh kW 217.8 226.4 235.4 231.2 238.2 243.2 246.8 253.2 257.8 63.8 66.4 69.0 67.8 69.8 71.3 72.3 74.2 75.6 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.30 .73 .89 1.00 20.38 .80 .97 1.00 20.46 .86 1.00 1.00 20.42 .56 .70 .85 20.50 .60 .77 .94 20.56 .64 .84 1.00 20.58 .42 .55 .68 20.66 .43 .59 .75 20.70 .44 .63 .82 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 21 TON HIGH EFFICIENCY − LGA248H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6720 8400 10080 6720 8400 10080 6720 8400 10080 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760 128.2 133.5 137.6 136.6 141.5 144.8 145.9 150.7 153.9 37.6 39.1 40.3 40.0 41.5 42.4 42.8 44.2 45.1 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.25 .54 5.29 .59 5.33 .66 5.31 .43 5.35 .45 5.38 .47 5.39 .33 5.43 .33 5.46 .34 80_F 27_C .71 .82 .92 .52 .56 .63 .41 .44 .46 85_F 29_C .91 1.00 1.00 .66 .77 .87 .50 .54 .59 Total Cooling Capacity kBtuh 123.4 128.4 132.5 131.5 136.0 139.1 140.4 144.8 147.8 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 36.2 6.08 .55 37.6 6.11 .61 38.8 6.15 .69 38.5 6.14 .43 39.9 6.17 .46 40.8 6.21 .48 41.1 6.22 .33 42.4 6.26 .33 43.3 6.29 .34 80_F 27_C .74 .85 .95 .53 .57 .65 .42 .44 .47 85_F 29_C .94 1.00 1.00 .68 .80 .91 .51 .55 .62 Total Cooling Capacity kBtuh kW 118.3 123.0 127.2 126.0 130.1 133.0 134.6 138.6 141.3 34.7 36.0 37.3 36.9 38.1 39.0 39.4 40.6 41.4 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 6.95 .56 6.99 .63 7.03 .71 7.02 .44 7.06 .46 7.09 .49 7.11 .33 7.15 .34 7.18 .35 80_F 27_C .76 .88 .98 .54 .59 .68 .42 .45 .48 85_F 29_C .97 1.00 1.00 .71 .83 .94 .52 .57 .65 Total Cooling Capacity kBtuh kW 112.9 117.4 121.7 120.2 123.9 126.6 128.3 132.0 134.4 33.1 34.4 35.7 35.2 36.3 37.1 37.6 38.7 39.4 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.91 .57 .80 1.00 7.97 .66 .92 1.00 7.99 .75 1.00 1.00 7.99 .44 .55 .74 8.03 .47 .62 .87 8.05 .50 .72 .98 8.07 .33 .43 .53 8.11 .34 .46 .59 8.15 .35 .49 .68 21 TON HIGH EFFICIENCY − LGA248H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6720 8400 10080 6720 8400 10080 6720 8400 10080 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760 247.6 257.2 266.0 263.4 272.0 278.2 281.4 289.8 295.4 72.6 75.4 78.0 77.2 79.7 81.5 82.5 84.9 86.6 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 13.94 .66 14.02 .72 14.10 .78 14.08 .52 14.16 .55 14.22 .58 14.24 .39 14.34 .40 14.40 .41 80_F 27_C .82 .92 .99 .64 .69 .76 .50 .54 .57 85_F 29_C .98 1.00 1.00 .78 .87 .96 .62 .67 .73 Total Cooling Capacity kBtuh 236.2 245.4 254.4 251.2 259.0 264.6 268.2 275.6 280.8 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 69.2 15.86 .68 71.9 15.98 .74 74.6 16.02 .81 73.6 16.02 .53 75.9 16.10 .56 77.5 16.16 .59 78.6 16.18 .39 80.8 16.26 .40 82.3 16.34 .42 80_F 27_C .84 .94 1.00 .65 .71 .78 .51 .55 .58 85_F 29_C 1.00 1.00 1.00 .80 .90 .98 .63 .69 .76 Total Cooling Capacity kBtuh kW 223.6 232.8 242.4 237.8 244.8 250.0 253.8 260.8 265.2 65.5 68.2 71.0 69.7 71.7 73.3 74.4 76.4 77.7 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 18.06 .69 18.14 .77 18.22 .84 18.18 .53 18.26 .57 18.30 .61 18.36 .39 18.42 .41 18.48 .42 80_F 27_C .88 .97 1.00 .67 .74 .82 .52 .56 .60 85_F 29_C 1.00 1.00 1.00 .83 .94 1.00 .65 .71 .79 Total Cooling Capacity kBtuh kW 210.2 219.8 229.4 223.2 229.8 234.6 238.4 244.4 248.4 61.6 64.4 67.2 65.4 67.3 68.8 69.9 71.6 72.8 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.50 .71 .92 1.00 20.58 .80 1.00 1.00 20.66 .88 1.00 1.00 20.62 .55 .69 .87 20.70 .59 .77 .98 20.74 .63 .86 1.00 20.80 .40 .53 .67 20.86 .41 .58 .74 20.90 .43 .62 .83 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 29 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − ONE COMPRESSOR OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperat ure Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 1680 795 2100 990 2520 1190 1680 795 2100 990 2520 1190 1680 795 2100 990 2520 1190 49.3 52.9 55.4 53.0 56.7 59.3 56.9 60.8 63.5 14.4 15.5 16.2 15.5 16.6 17.4 16.7 17.8 18.6 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 4.32 .64 4.36 .65 4.38 .67 4.36 .53 4.40 .53 4.43 .54 4.40 .43 4.45 .43 4.48 .42 80_F 27_C .72 .74 .77 .61 .62 .64 .50 .51 .52 Total Cooling Capacity 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 85_F 75_F kBtuh kW Input 29_C 24_C .80 48.1 14.1 4.84 .64 .84 51.4 15.1 4.88 .65 .88 53.8 15.8 4.91 .67 .68 51.7 15.2 4.88 .53 .71 55.1 16.1 4.92 .53 .74 57.6 16.9 4.95 .54 .57 55.5 16.3 4.93 .43 .59 59.1 17.3 4.97 .43 .61 61.7 18.1 5.00 .42 80_F 27_C .72 .75 .78 .61 .62 .65 .50 .51 .52 Total Cooling Capacity 85_F kBtuh kW 29_C .80 46.7 13.7 .84 49.9 14.6 .89 52.1 15.3 .68 50.2 14.7 .71 53.4 15.6 .75 55.7 16.3 .58 53.9 15.8 .59 57.3 16.8 .62 59.6 17.5 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.45 .64 5.49 .66 5.52 .68 5.50 .53 5.53 .54 5.56 .55 5.54 .43 5.58 .42 5.61 .42 80_F 27_C .73 .76 .79 .61 .63 .65 .50 .51 .52 Total Cooling Capacity 85_F kBtuh kW 29_C .81 45.2 13.2 .85 48.1 14.1 .90 50.2 14.7 .69 48.6 14.2 .72 51.6 15.1 .76 53.7 15.7 .58 52.1 15.3 .60 55.3 16.2 .62 57.5 16.9 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.16 .64 .73 .82 6.19 .66 .77 .87 6.22 .69 .80 .92 6.20 .53 .61 .69 6.24 .54 .63 .73 6.26 .55 .66 .77 6.25 .43 .51 .58 6.28 .42 .52 .60 6.32 .43 .53 .63 21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 3570 4200 4830 3570 4200 4830 3570 4200 4830 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 1685 1980 2280 1685 1980 2280 1685 1980 2280 135.1 139.0 142.2 144.3 147.9 150.7 154.0 157.8 160.6 39.6 40.7 41.7 42.3 43.3 44.2 45.1 46.2 47.1 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.45 .73 7.49 .76 7.52 .80 7.54 .57 7.57 .59 7.60 .62 7.62 .43 7.67 .44 7.69 .45 80_F 27_C .87 .91 .96 .70 .74 .78 .56 .58 .60 85_F 29_C .99 1.00 1.00 .83 .88 .93 .68 .71 .75 Total Cooling Capacity kBtuh 131.2 134.9 138.1 140.0 143.4 146.0 149.4 152.9 155.5 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 38.5 8.33 .74 39.5 8.36 .77 40.5 8.40 .81 41.0 8.41 .58 42.0 8.45 .60 42.8 8.47 .62 43.8 8.50 .43 44.8 8.55 .44 45.6 8.57 .45 80_F 27_C .88 .93 .97 .71 .75 .79 .56 .58 .61 85_F 29_C 1.00 1.00 1.00 .84 .89 .94 .68 .73 .77 Total Cooling Capacity kBtuh kW 127.0 130.5 133.5 135.4 138.6 141.0 144.4 147.7 150.1 37.2 38.2 39.1 39.7 40.6 41.3 42.3 43.3 44.0 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 9.36 .75 9.39 .79 9.43 .83 9.44 .58 9.48 .61 9.50 .63 9.53 .44 9.57 .45 9.60 .46 80_F 27_C .89 .94 .99 .72 .76 .80 .57 .59 .62 85_F 29_C 1.00 1.00 1.00 .86 .91 .96 .70 .74 .78 Total Cooling Capacity kBtuh kW 122.4 125.8 128.8 130.3 133.4 135.6 139.2 142.1 144.4 35.9 36.9 37.7 38.2 39.1 39.7 40.8 41.6 42.3 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 10.54 .76 .91 1.00 10.58 .80 .96 1.00 10.61 .84 1.00 1.00 10.62 .59 .73 .87 10.66 .61 .78 .93 10.68 .64 .82 .98 10.72 .44 .57 .71 10.75 .45 .60 .75 10.78 .46 .63 .80 21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − THREE COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 5040 6300 7560 5040 6300 7560 5040 6300 7560 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2380 2975 3570 2380 2975 3570 2380 2975 3570 197.1 205.0 212.2 208.9 214.3 218.3 222.5 227.5 231.1 57.8 60.1 62.2 61.2 62.8 64.0 65.2 66.7 67.7 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 11.48 .69 11.55 .75 11.62 .83 11.59 .53 11.64 .57 11.68 .60 11.73 .39 11.78 .40 11.82 .42 80_F 27_C .89 .97 1.00 .67 .73 .80 .52 .56 .60 85_F 29_C 1.00 1.00 1.00 .85 .95 .99 .65 .71 .78 Total Cooling Capacity kBtuh 191.5 199.5 206.5 202.7 207.7 211.6 215.7 220.5 223.8 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 56.1 12.83 .70 58.5 12.90 .77 60.5 12.98 .85 59.4 12.93 .54 60.9 12.99 .57 62.0 13.03 .61 63.2 13.07 .39 64.6 13.13 .40 65.6 13.17 .42 80_F 27_C .91 .98 1.00 .68 .74 .82 .52 .57 .60 85_F 29_C 1.00 1.00 1.00 .86 .96 1.00 .66 .72 .80 Total Cooling Capacity kBtuh kW 185.6 193.5 200.3 195.9 200.7 204.5 208.4 212.9 216.1 54.4 56.7 58.7 57.4 58.8 59.9 61.1 62.4 63.3 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 14.41 .71 14.47 .79 14.56 .87 14.52 .54 14.57 .58 14.62 .62 14.65 .39 14.70 .41 14.75 .42 80_F 27_C .93 .99 1.00 .69 .76 .84 .53 .57 .62 85_F 29_C 1.00 1.00 1.00 .89 .97 1.00 .67 .74 .82 Total Cooling Capacity kBtuh kW 179.2 187.2 193.9 188.7 193.3 196.9 200.8 204.9 207.8 52.5 54.9 56.8 55.3 56.7 57.7 58.8 60.1 60.9 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.23 .73 .95 1.00 16.32 .81 1.00 1.00 16.38 .89 1.00 1.00 16.34 .55 .71 .91 16.39 .59 .78 .99 16.45 .63 .87 1.00 16.48 .39 .54 .69 16.53 .41 .59 .76 16.57 .43 .63 .84 21 TON HIGH EFFICIENCY − LGA248H2V (R−22/VAV) − COOLING CAPACITY − FOUR COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6720 8400 10080 6720 8400 10080 6720 8400 10080 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3170 3965 4760 3170 3965 4760 3170 3965 4760 244.4 254.7 262.3 253.0 258.7 264.1 268.2 272.7 276.0 71.6 74.6 76.9 74.1 75.8 77.4 78.6 79.9 80.9 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 17.92 .71 18.02 .76 18.09 .89 18.00 .53 18.09 .58 18.14 .62 18.17 .37 18.23 .39 18.27 .41 80_F 27_C .98 1.00 1.00 .69 .75 .85 .53 .57 .62 85_F 29_C 1.00 1.00 1.00 .93 1.00 1.00 .68 .74 .82 Total Cooling Capacity kBtuh 236.4 246.4 253.6 243.8 249.3 254.8 258.2 262.3 265.6 Comp Motor kW 75_F kW Input 24_C 69.3 20.18 .72 72.2 20.28 .80 74.3 20.37 .92 71.5 20.28 .54 73.1 20.35 .59 74.7 20.39 .63 75.7 20.44 .37 76.9 20.49 .39 77.8 20.54 .41 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 30 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C 1.00 1.00 1.00 .71 .76 .89 .54 .59 .63 85_F 29_C 1.00 1.00 1.00 .96 1.00 1.00 .69 .75 .86 Total Cooling Capacity kBtuh kW 228.2 237.6 244.5 234.0 239.7 245.3 247.8 251.6 254.7 66.9 69.6 71.7 68.6 70.2 71.9 72.6 73.7 74.6 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 22.77 .73 22.89 .85 22.98 .95 22.87 .55 22.94 .60 23.00 .65 23.04 .38 23.11 .40 23.11 .42 80_F 27_C 1.00 1.00 1.00 .72 .81 .93 .55 .60 .65 85_F 29_C 1.00 1.00 1.00 .99 1.00 1.00 .71 .77 .90 Total Cooling Capacity kBtuh kW 219.5 228.2 234.8 224.0 229.7 235.2 236.9 240.6 243.4 64.3 66.9 68.8 65.6 67.3 68.9 69.4 70.5 71.3 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 25.76 .75 1.00 1.00 25.86 .89 1.00 1.00 25.93 .99 1.00 1.00 25.84 .56 .74 1.00 25.91 .62 .85 1.00 25.93 .66 .97 1.00 26.01 .38 .56 .72 26.07 .41 .61 .82 26.09 .43 .66 .94 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 25 TON STANDARD EFFICIENCY − LGC300S (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 149.0 154.6 159.2 158.0 162.8 166.2 167.8 172.4 175.6 43.7 45.3 46.7 46.3 47.7 48.7 49.2 50.5 51.5 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 8.34 .61 8.46 .66 8.56 .73 8.52 .48 8.64 .50 8.74 .53 8.76 .36 8.88 .37 8.96 .38 80_F 27_C .77 .86 .95 .59 .63 .70 .46 .49 .52 85_F 29_C .94 1.00 1.00 .72 .82 .91 .56 .61 .67 Total Cooling Capacity kBtuh 144.6 150.0 154.4 153.2 157.8 161.0 162.6 167.2 170.0 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 42.4 9.28 .61 44.0 9.42 .67 45.3 9.52 .74 44.9 9.48 .48 46.2 9.60 .51 47.2 9.70 .54 47.7 9.74 .36 49.0 9.84 .37 49.8 9.94 .38 80_F 27_C .78 .88 .96 .59 .64 .71 .47 .50 .53 85_F 29_C .95 1.00 1.00 .74 .84 .93 .57 .62 .69 Total Cooling Capacity kBtuh kW 140.0 145.2 149.6 148.0 152.4 155.6 157.4 161.4 164.2 41.0 42.6 43.8 43.4 44.7 45.6 46.1 47.3 48.1 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 10.38 .62 10.50 .69 10.62 .76 10.58 .49 10.70 .51 10.78 .55 10.82 .36 10.94 .37 11.02 .39 80_F 27_C .80 .90 .98 .60 .66 .73 .47 .50 .54 85_F 29_C .97 1.00 1.00 .75 .86 .95 .58 .63 .71 Total Cooling Capacity kBtuh kW 135.0 140.0 144.6 142.8 146.8 149.8 151.6 155.4 158.2 39.6 41.0 42.4 41.9 43.0 43.9 44.4 45.5 46.4 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.62 .63 .82 .99 11.74 .71 .93 1.00 11.88 .78 1.00 1.00 11.82 .49 .61 .78 11.94 .52 .68 .89 12.04 .55 .76 .97 12.08 .37 .48 .59 12.20 .38 .51 .65 12.28 .39 .55 .73 25 TON STANDARD EFFICIENCY − LGC300S (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 291.5 302.4 311.6 308.4 317.4 324.1 327.8 336.3 342.1 85.4 88.6 91.3 90.4 93.0 95.0 96.1 98.6 100.3 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 20.90 .70 21.15 .76 21.38 .82 21.30 .55 21.55 .58 21.71 .61 21.79 .41 22.03 .42 22.20 .43 80_F 27_C .86 .95 1.00 .68 .73 .80 .53 .57 .60 85_F 29_C 1.00 1.00 1.00 .82 .91 .99 .65 .71 .77 Total Cooling Capacity kBtuh 281.1 291.7 301.3 297.4 305.9 312.2 315.9 323.9 329.6 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 82.4 23.41 .71 85.5 23.65 .77 88.3 23.92 .84 87.2 23.81 .55 89.7 24.05 .59 91.5 24.24 .62 92.6 24.33 .41 94.9 24.57 .42 96.6 24.73 .44 80_F 27_C .88 .97 1.00 .69 .75 .82 .54 .58 .61 85_F 29_C 1.00 1.00 1.00 .84 .93 1.00 .66 .73 .79 Total Cooling Capacity kBtuh kW 270.1 280.5 290.1 285.5 293.5 299.4 303.4 311.0 316.0 79.2 82.2 85.0 83.7 86.0 87.7 88.9 91.1 92.6 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 26.23 .72 26.51 .79 26.79 .86 26.67 .56 26.91 .60 27.11 .63 27.23 .41 27.43 .43 27.63 .44 80_F 27_C .90 .99 1.00 .70 .77 .84 .55 .59 .63 85_F 29_C 1.00 1.00 1.00 .86 .96 1.00 .68 .74 .82 Total Cooling Capacity kBtuh kW 258.4 268.5 278.7 272.7 280.2 286.0 290.1 297.0 301.6 75.7 78.7 81.7 79.9 82.1 83.8 85.0 87.0 88.4 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 29.44 .74 .92 1.00 29.74 .81 1.00 1.00 30.05 .89 1.00 1.00 29.89 .57 .71 .88 30.17 .61 .79 .98 30.37 .65 .87 1.00 30.46 .42 .55 .69 30.67 .43 .60 .76 30.87 .45 .64 .84 25 TON HIGH EFFICIENCY − LGC300H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 157.5 163.6 168.5 167.5 173.2 177.2 178.5 184.2 187.9 46.2 47.9 49.4 49.1 50.8 51.9 52.3 54.0 55.1 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 8.00 .58 8.08 .63 8.14 .69 8.12 .46 8.19 .48 8.25 .51 8.27 .35 8.34 .36 8.39 .37 80_F 27_C .73 .83 .91 .56 .60 .66 .44 .47 .49 85_F 29_C .90 .99 1.00 .69 .78 .87 .54 .58 .63 Total Cooling Capacity kBtuh 152.7 158.6 163.4 162.4 167.7 171.5 173.0 178.3 181.8 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 44.8 9.01 .59 46.5 9.11 .64 47.9 9.17 .71 47.6 9.16 .46 49.1 9.25 .49 50.3 9.31 .51 50.7 9.33 .35 52.3 9.41 .36 53.3 9.48 .37 80_F 27_C .75 .85 .93 .57 .61 .67 .45 .47 .50 85_F 29_C .92 1.00 1.00 .70 .80 .89 .55 .59 .65 Total Cooling Capacity kBtuh kW 147.9 153.6 158.4 157.1 162.2 165.8 167.5 172.4 175.7 43.3 45.0 46.4 46.0 47.5 48.6 49.1 50.5 51.5 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 10.09 .60 10.20 .65 10.28 .72 10.26 .47 10.36 .49 10.43 .52 10.45 .35 10.55 .36 10.61 .37 80_F 27_C .77 .87 .95 .57 .62 .69 .45 .48 .51 85_F 29_C .94 1.00 1.00 .72 .82 .91 .55 .60 .66 Total Cooling Capacity kBtuh kW 143.0 148.4 153.1 151.8 156.5 160.0 161.7 166.3 169.5 41.9 43.5 44.9 44.5 45.9 46.9 47.4 48.7 49.7 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.28 .60 .79 .96 11.39 .67 .89 1.00 11.49 .74 .97 1.00 11.46 .47 .58 .74 11.57 .50 .64 .85 11.64 .53 .71 .94 11.67 .35 .46 .56 11.77 .36 .49 .61 11.85 .37 .52 .69 25 TON HIGH EFFICIENCY − LGC300H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 294.0 305.2 314.8 312.4 322.4 329.6 332.8 342.6 349.4 86.2 89.4 92.3 91.6 94.5 96.6 97.5 100.4 102.4 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 18.94 .67 19.16 .72 19.30 .78 19.26 .53 19.46 .56 19.58 .59 19.62 .40 19.80 .41 19.94 .42 80_F 27_C .82 .90 .96 .65 .70 .76 .51 .54 .57 85_F 29_C .96 1.00 1.00 .78 .86 .93 .62 .68 .73 Total Cooling Capacity kBtuh 284.2 295.2 304.2 301.8 311.2 318.0 321.4 330.6 337.0 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 83.3 21.18 .68 86.5 21.38 .74 89.2 21.56 .80 88.4 21.52 .53 91.2 21.70 .56 93.2 21.84 .59 94.2 21.90 .40 96.9 22.10 .41 98.8 22.24 .42 80_F 27_C .83 .91 .98 .66 .71 .77 .52 .55 .58 85_F 29_C .97 1.00 1.00 .79 .88 .95 .63 .69 .75 Total Cooling Capacity kBtuh kW 274.0 284.4 293.6 290.6 299.4 305.6 309.4 318.0 323.6 80.3 83.3 86.0 85.2 87.7 89.6 90.7 93.2 94.8 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 23.66 .69 23.88 .75 24.06 .82 24.06 .54 24.22 .57 24.40 .60 24.48 .40 24.66 .41 24.82 .43 80_F 27_C .85 .93 .99 .67 .73 .79 .52 .56 .59 85_F 29_C .99 1.00 1.00 .81 .90 .97 .65 .70 .77 Total Cooling Capacity kBtuh kW 262.6 272.8 282.2 278.4 286.6 292.4 296.4 304.4 309.8 77.0 79.9 82.7 81.6 84.0 85.7 86.9 89.2 90.8 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 26.46 .70 .87 1.00 26.74 .77 .96 1.00 26.98 .84 1.00 1.00 26.88 .55 .68 .83 27.08 .58 .75 .92 27.28 .62 .81 .99 27.34 .40 .53 .66 27.54 .42 .57 .72 27.70 .43 .61 .79 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 31 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − ONE COMPRESSOR OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 2000 2500 3000 2000 2500 3000 2000 2500 3000 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 945 1180 1415 945 1180 1415 945 1180 1415 59.8 64.2 67.4 64.3 68.9 72.2 69.0 73.8 77.2 17.5 18.8 19.8 18.8 20.2 21.2 20.2 21.6 22.6 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.10 .60 5.19 .61 5.25 .63 5.20 .50 5.28 .50 5.34 .51 5.29 .41 5.38 .41 5.44 .40 80_F 27_C .68 .71 .73 .57 .58 .60 .48 .48 .49 Total Cooling Capacity 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 85_F 75_F kBtuh kW Input 29_C 24_C .76 58.2 17.1 5.75 .61 .80 62.4 18.3 5.85 .62 .84 65.4 19.2 5.92 .64 .64 62.6 18.3 5.86 .50 .67 67.0 19.6 5.96 .51 .70 70.1 20.5 6.03 .51 .54 67.2 19.7 5.97 .41 .56 71.8 21.0 6.08 .41 .57 75.0 22.0 6.15 .40 80_F 27_C .69 .71 .74 .57 .59 .61 .48 .48 .49 Total Cooling Capacity 85_F kBtuh kW 29_C .77 56.7 16.6 .81 60.6 17.8 .85 63.4 18.6 .65 60.9 17.8 .67 65.0 19.0 .71 67.9 19.9 .54 65.5 19.2 .56 69.7 20.4 .58 72.7 21.3 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 6.45 .61 6.55 .62 6.63 .64 6.57 .50 6.68 .51 6.76 .51 6.70 .41 6.81 .40 6.89 .40 80_F 27_C .69 .72 .75 .58 .59 .61 .48 .48 .49 Total Cooling Capacity 85_F kBtuh kW 29_C .77 55.0 16.1 .82 58.7 17.2 .86 61.4 18.0 .65 59.1 17.3 .68 63.0 18.5 .71 65.7 19.3 .55 63.5 18.6 .56 67.5 19.8 .58 70.3 20.6 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.22 .61 .70 .78 7.33 .63 .73 .83 7.42 .65 .76 .88 7.35 .50 .58 .66 7.47 .51 .59 .69 7.55 .52 .62 .72 7.49 .41 .48 .55 7.62 .40 .48 .57 7.70 .40 .50 .59 25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4000 5000 6000 4000 5000 6000 4000 5000 6000 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 1890 2360 2830 1890 2360 2830 1890 2360 2830 156.1 162.4 167.4 166.8 172.7 177.0 177.9 184.0 188.4 45.7 47.6 49.1 48.9 50.6 51.9 52.1 53.9 55.2 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 9.43 .71 9.54 .75 9.61 .80 9.59 .57 9.70 .59 9.76 .62 9.77 .43 9.87 .44 9.94 .45 80_F 27_C .84 .91 .97 .68 .73 .78 .55 .57 .60 85_F 29_C .97 1.00 1.00 .81 .87 .94 .66 .70 .75 Total Cooling Capacity kBtuh 151.3 157.4 162.0 161.5 167.2 171.2 172.4 178.1 182.2 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 44.3 10.63 .72 46.1 10.74 .77 47.5 10.84 .82 47.3 10.83 .57 49.0 10.95 .60 50.2 11.02 .62 50.5 11.04 .43 52.2 11.15 .44 53.4 11.22 .45 80_F 27_C .85 .92 .98 .69 .74 .79 .55 .58 .61 85_F 29_C .98 1.00 1.00 .82 .89 .95 .66 .71 .76 Total Cooling Capacity kBtuh kW 146.5 152.2 156.8 156.3 161.6 165.3 166.8 172.2 175.9 42.9 44.6 46.0 45.8 47.4 48.4 48.9 50.5 51.6 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 11.92 .73 12.03 .78 12.15 .83 12.13 .57 12.25 .60 12.35 .63 12.36 .44 12.49 .44 12.59 .46 80_F 27_C .87 .94 1.00 .70 .75 .80 .56 .59 .62 85_F 29_C 1.00 1.00 1.00 .83 .90 .97 .67 .72 .78 Total Cooling Capacity kBtuh kW 141.5 147.0 151.4 150.9 155.9 159.4 161.0 166.1 169.4 41.5 43.1 44.4 44.2 45.7 46.7 47.2 48.7 49.6 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 13.32 .74 .88 1.00 13.44 .79 .95 1.00 13.56 .84 1.00 1.00 13.55 .58 .71 .85 13.69 .61 .76 .92 13.78 .64 .82 .99 13.81 .44 .56 .68 13.94 .45 .59 .74 14.04 .46 .63 .80 25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − THREE COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6000 7500 9000 6000 7500 9000 6000 7500 9000 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2830 3540 4250 2830 3540 4250 2830 3540 4250 238.8 247.2 255.4 252.9 259.5 264.2 269.0 275.3 279.8 70.0 72.4 74.9 74.1 76.1 77.4 78.8 80.7 82.0 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 14.71 .69 14.83 .74 14.97 .82 14.93 .53 15.04 .56 15.12 .59 15.19 .39 15.31 .40 15.38 .42 80_F 27_C .88 .97 1.00 .67 .72 .79 .52 .55 .59 85_F 29_C 1.00 1.00 1.00 .83 .93 1.00 .64 .70 .76 Total Cooling Capacity kBtuh 231.3 239.8 247.9 244.9 251.0 255.6 260.5 266.3 270.5 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 67.8 16.58 .70 70.3 16.74 .76 72.7 16.91 .84 71.8 16.85 .54 73.6 16.98 .57 74.9 17.07 .60 76.3 17.15 .39 78.0 17.28 .40 79.3 17.37 .42 80_F 27_C .90 .99 1.00 .68 .73 .81 .52 .56 .60 85_F 29_C 1.00 1.00 1.00 .85 .95 1.00 .65 .71 .78 Total Cooling Capacity kBtuh kW 224.0 232.5 240.4 236.8 242.5 246.9 251.8 257.3 261.0 65.6 68.1 70.5 69.4 71.1 72.4 73.8 75.4 76.5 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 18.58 .71 18.77 .78 18.95 .86 18.88 .54 19.02 .58 19.12 .61 19.23 .39 19.36 .41 19.45 .42 80_F 27_C .92 1.00 1.00 .69 .75 .83 .53 .57 .61 85_F 29_C 1.00 1.00 1.00 .88 .97 1.00 .67 .73 .80 Total Cooling Capacity kBtuh kW 216.5 225.2 232.9 228.5 233.8 238.2 242.8 247.9 251.5 63.4 66.0 68.3 67.0 68.5 69.8 71.2 72.7 73.7 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.76 .72 .94 1.00 20.97 .80 1.00 1.00 21.19 .88 1.00 1.00 21.08 .55 .70 .90 21.23 .59 .77 .99 21.34 .62 .85 1.00 21.47 .40 .54 .68 21.60 .41 .58 .75 21.71 .43 .62 .83 25 TON HIGH EFFICIENCY − LGC300H2V (R−22/VAV) − COOLING CAPACITY − FOUR COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 304.1 316.2 325.9 316.5 323.5 329.3 335.4 341.3 345.2 89.1 92.7 95.5 92.8 94.8 96.5 98.3 100.0 101.2 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 23.84 .70 24.12 .76 24.36 .88 24.13 .53 24.29 .57 24.42 .61 24.57 .37 24.71 .39 24.79 .41 80_F 27_C .97 1.00 1.00 .69 .74 .85 .52 .57 .61 85_F 29_C 1.00 1.00 1.00 .93 1.00 1.00 .67 .73 .81 Total Cooling Capacity kBtuh 294.7 306.4 315.7 305.4 312.1 317.9 323.5 328.8 332.8 Comp Motor kW 75_F kW Input 24_C 86.4 26.66 .71 89.8 26.98 .80 92.5 27.19 .91 89.5 26.94 .54 91.5 27.12 .58 93.2 27.27 .62 94.8 27.41 .38 96.4 27.56 .39 97.5 27.66 .41 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 32 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .99 1.00 1.00 .70 .76 .88 .53 .58 .62 85_F 29_C 1.00 1.00 1.00 .95 1.00 1.00 .68 .74 .85 Total Cooling Capacity kBtuh kW 284.6 296.0 304.7 293.8 300.1 306.4 310.9 316.1 319.6 83.4 86.7 89.3 86.1 88.0 89.8 91.1 92.6 93.7 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 29.78 .73 30.11 .84 30.37 .94 30.07 .55 30.25 .59 30.44 .63 30.58 .38 30.72 .40 30.84 .42 80_F 27_C 1.00 1.00 1.00 .71 .80 .92 .54 .59 .63 85_F 29_C 1.00 1.00 1.00 .98 1.00 1.00 .70 .76 .89 Total Cooling Capacity kBtuh kW 273.8 284.8 292.9 281.3 287.6 294.0 297.5 302.0 305.5 80.2 83.5 85.8 82.4 84.3 86.2 87.2 88.5 89.5 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 33.35 .74 1.00 1.00 33.70 .88 1.00 1.00 33.98 .97 1.00 1.00 33.61 .56 .73 1.00 33.83 .61 .85 1.00 34.00 .65 .95 1.00 34.12 .38 .55 .71 34.31 .41 .60 .81 34.43 .43 .65 .93 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 30 TON HIGH EFFICIENCY − LGA360H (R−22/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 9000 11200 13400 9000 11200 13400 9000 11200 13400 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 4250 5285 6325 4250 5285 6325 4250 5285 6325 228.1 236.4 242.9 241.8 249.1 254.2 256.8 263.7 268.6 66.8 69.3 71.2 70.9 73.0 74.5 75.3 77.3 78.7 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 11.16 .65 11.32 .70 11.44 .75 11.42 .51 11.56 .54 11.67 .56 11.72 .39 11.87 .40 11.98 .41 80_F 27_C .79 .87 .94 .63 .67 .73 .50 .53 .55 85_F 29_C .93 1.00 1.00 .76 .83 .91 .61 .65 .70 Total Cooling Capacity kBtuh 222.4 230.4 236.8 235.6 242.6 247.6 250.2 257.0 261.6 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 65.2 12.26 .66 67.5 12.42 .71 69.4 12.53 .76 69.0 12.51 .52 71.1 12.65 .54 72.6 12.77 .57 73.3 12.81 .39 75.3 12.95 .40 76.7 13.07 .41 80_F 27_C .80 .88 .95 .63 .68 .74 .50 .53 .56 85_F 29_C .95 1.00 1.00 .77 .85 .92 .61 .66 .72 Total Cooling Capacity kBtuh kW 216.0 223.6 230.0 228.7 235.3 240.1 242.9 249.3 253.7 63.3 65.5 67.4 67.0 69.0 70.4 71.2 73.1 74.4 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 13.51 .66 13.67 .72 13.79 .78 13.76 .52 13.91 .55 14.00 .58 14.06 .39 14.21 .40 14.30 .41 80_F 27_C .82 .90 .97 .64 .69 .75 .51 .54 .57 85_F 29_C .96 1.00 1.00 .78 .86 .94 .62 .67 .73 Total Cooling Capacity kBtuh kW 208.7 216.2 222.6 221.0 227.2 231.9 234.8 240.7 245.0 61.2 63.4 65.2 64.8 66.6 68.0 68.8 70.5 71.8 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 14.96 .67 .83 .98 15.08 .73 .92 1.00 15.21 .79 .98 1.00 15.19 .53 .65 .80 15.34 .56 .71 .88 15.42 .59 .77 .95 15.49 .39 .51 .63 15.63 .40 .54 .68 15.72 .42 .58 .75 30 TON HIGH EFFICIENCY − LGA360H (R−22/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 9000 11200 13400 9000 11200 13400 9000 11200 13400 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 4250 5285 6325 4250 5285 6325 4250 5285 6325 340.0 352.4 362.6 360.3 370.6 378.2 382.9 392.8 399.7 99.6 103.3 106.3 105.6 108.6 110.8 112.2 115.1 117.1 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 22.02 .71 22.26 .76 22.46 .82 22.41 .55 22.64 .58 22.77 .62 22.87 .42 23.09 .43 23.26 .44 80_F 27_C .85 .92 .98 .68 .74 .79 .54 .57 .61 85_F 29_C .98 1.00 1.00 .82 .89 .96 .66 .72 .77 Total Cooling Capacity kBtuh 328.5 340.4 350.9 347.8 357.7 365.0 369.9 379.2 385.7 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 96.3 24.34 .72 99.8 24.55 .77 102.8 24.76 .83 101.9 24.70 .56 104.8 24.93 .59 107.0 25.07 .63 108.4 25.17 .42 111.1 25.39 .43 113.0 25.53 .44 80_F 27_C .87 .94 .99 .69 .75 .81 .54 .58 .62 85_F 29_C .99 1.00 1.00 .83 .91 .97 .67 .73 .79 Total Cooling Capacity kBtuh kW 315.8 327.5 338.2 334.1 343.6 350.4 355.4 364.2 370.2 92.6 96.0 99.1 97.9 100.7 102.7 104.2 106.7 108.5 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 26.98 .73 27.17 .79 27.40 .85 27.34 .57 27.53 .60 27.69 .64 27.81 .42 27.98 .43 28.13 .45 80_F 27_C .88 .96 1.00 .71 .77 .83 .55 .59 .63 85_F 29_C 1.00 1.00 1.00 .85 .93 .99 .68 .75 .81 Total Cooling Capacity kBtuh kW 302.2 313.6 324.6 319.5 328.2 334.4 339.6 347.9 353.0 88.6 91.9 95.1 93.6 96.2 98.0 99.5 102.0 103.5 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 29.91 .74 .90 1.00 30.17 .81 .98 1.00 30.41 .87 1.00 1.00 30.31 .58 .72 .87 30.49 .61 .79 .95 30.68 .65 .85 1.00 30.78 .42 .56 .70 30.96 .44 .60 .76 31.13 .45 .64 .83 30 TON HIGH EFFICIENCY − LGA360H (R−410A/CAV) − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 9600 12000 14400 9600 12000 14400 9600 12000 14400 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 4530 5665 6795 4530 5665 6795 4530 5665 6795 263.3 272.8 280.2 278.8 287.4 293.5 295.4 304.0 310.0 77.2 79.9 82.1 81.7 84.2 86.0 86.6 89.1 90.9 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 14.58 .60 14.72 .64 14.85 .70 14.81 .48 14.95 .50 15.05 .52 15.07 .36 15.21 .37 15.30 .38 80_F 27_C .74 .82 .90 .58 .62 .67 .46 .48 .51 85_F 29_C .89 .98 1.00 .70 .78 .86 .55 .60 .64 Total Cooling Capacity kBtuh 254.3 263.7 270.8 269.5 277.7 283.5 285.8 294.0 299.6 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 74.5 16.10 .61 77.3 16.28 .65 79.4 16.41 .71 79.0 16.36 .48 81.4 16.52 .50 83.1 16.63 .53 83.8 16.67 .37 86.2 16.83 .37 87.8 16.93 .38 80_F 27_C .76 .84 .92 .58 .62 .69 .46 .49 .52 85_F 29_C .91 .99 1.00 .71 .80 .88 .56 .61 .66 Total Cooling Capacity kBtuh kW 244.3 253.1 260.3 258.8 266.5 272.0 274.7 282.3 287.4 71.6 74.2 76.3 75.8 78.1 79.7 80.5 82.7 84.2 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 18.00 .61 18.18 .67 18.33 .73 18.28 .48 18.46 .51 18.59 .53 18.63 .37 18.80 .37 18.92 .38 80_F 27_C .78 .86 .94 .59 .64 .71 .47 .50 .52 85_F 29_C .93 1.00 1.00 .73 .82 .91 .57 .62 .68 Total Cooling Capacity kBtuh kW 233.0 241.5 248.6 246.7 253.9 259.1 262.1 269.0 273.7 68.3 70.8 72.9 72.3 74.4 75.9 76.8 78.8 80.2 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.28 .62 .80 .96 20.49 .69 .89 1.00 20.63 .76 .97 1.00 20.58 .49 .60 .76 20.77 .52 .66 .85 20.91 .54 .73 .93 20.95 .37 .48 .58 21.13 .38 .51 .64 21.27 .39 .54 .71 30 TON HIGH EFFICIENCY − LGA360H (R−410A/CAV) − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 9600 12000 14400 9600 12000 14400 9600 12000 14400 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 4530 5665 6795 4530 5665 6795 4530 5665 6795 371.1 384.2 395.4 392.9 404.3 412.4 417.0 428.0 435.7 108.8 112.6 115.9 115.1 118.5 120.9 122.2 125.4 127.7 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 25.91 .68 26.20 .73 26.36 .78 26.30 .53 26.54 .56 26.74 .59 26.80 .40 27.04 .41 27.19 .42 80_F 27_C .82 .90 .96 .65 .71 .76 .52 .55 .58 85_F 29_C .96 1.00 1.00 .78 .86 .94 .63 .69 .74 Total Cooling Capacity kBtuh 352.8 365.4 376.6 373.2 383.7 391.7 396.3 406.2 413.3 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 103.4 29.18 .69 107.1 29.46 .75 110.4 29.68 .81 109.4 29.59 .54 112.5 29.86 .57 114.8 30.03 .60 116.1 30.12 .40 119.0 30.39 .42 121.1 30.54 .43 80_F 27_C .84 .92 .98 .67 .72 .79 .53 .56 .60 85_F 29_C .98 1.00 1.00 .81 .89 .96 .65 .70 .76 Total Cooling Capacity kBtuh kW 332.4 345.0 355.9 351.3 361.3 368.3 373.2 382.2 388.7 97.4 101.1 104.3 103.0 105.9 107.9 109.4 112.0 113.9 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 33.00 .71 33.22 .77 33.52 .84 33.45 .55 33.64 .59 33.81 .62 33.98 .41 34.22 .42 34.35 .44 80_F 27_C .87 .95 1.00 .69 .75 .82 .54 .57 .61 85_F 29_C 1.00 1.00 1.00 .84 .92 .99 .67 .73 .80 Total Cooling Capacity kBtuh kW 310.2 322.0 333.8 327.2 336.0 342.3 347.4 355.7 360.7 90.9 94.4 97.8 95.9 98.5 100.3 101.8 104.2 105.7 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 37.29 .73 .91 1.00 37.56 .81 .99 1.00 37.86 .88 1.00 1.00 37.71 .56 .71 .87 37.94 .60 .78 .96 38.15 .64 .86 1.00 38.27 .41 .55 .69 38.48 .43 .59 .76 38.63 .44 .64 .83 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 33 COOLING RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − ONE COMPRESSOR OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 2250 2800 3350 2250 2800 3350 2250 2800 3350 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 1060 1320 1580 1060 1320 1580 1060 1320 1580 67.5 72.2 75.5 72.5 77.4 80.8 77.9 82.8 86.4 19.8 21.2 22.1 21.2 22.7 23.7 22.8 24.3 25.3 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 5.73 .67 5.86 .68 5.96 .70 5.87 .56 6.01 .56 6.12 .57 6.03 .46 6.18 .45 6.29 .45 80_F 27_C .76 .78 .81 .64 .65 .67 .53 .54 .54 Total Cooling Capacity 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 85_F 75_F kBtuh kW Input 29_C 24_C .84 65.8 19.3 6.40 .67 .88 70.2 20.6 6.52 .69 .92 73.3 21.5 6.62 .71 .72 70.6 20.7 6.54 .56 .74 75.2 22.0 6.68 .56 .77 78.4 23.0 6.78 .57 .61 75.8 22.2 6.70 .46 .62 80.5 23.6 6.85 .45 .64 83.8 24.6 6.95 .45 80_F 27_C .76 .79 .82 .64 .66 .68 .53 .54 .55 Total Cooling Capacity 85_F kBtuh kW 29_C .85 63.8 18.7 .89 68.0 19.9 .93 70.9 20.8 .72 68.6 20.1 .75 72.9 21.4 .78 75.9 22.2 .61 73.6 21.6 .63 78.0 22.9 .65 81.1 23.8 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 7.16 .68 7.28 .69 7.37 .71 7.31 .56 7.43 .57 7.53 .57 7.47 .45 7.61 .45 7.71 .45 80_F 27_C .77 .80 .83 .64 .66 .68 .53 .54 .55 Total Cooling Capacity 85_F kBtuh kW 29_C .85 61.9 18.1 .90 65.7 19.3 .94 68.4 20.0 .73 66.4 19.5 .76 70.4 20.6 .79 73.2 21.5 .61 71.3 20.9 .63 75.4 22.1 .65 78.3 22.9 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.02 .68 .77 .86 8.14 .70 .80 .91 8.24 .72 .84 .96 8.17 .56 .65 .73 8.31 .57 .67 .77 8.40 .58 .69 .81 8.34 .45 .53 .61 8.49 .45 .54 .64 8.59 .45 .55 .66 30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4500 5400 6300 4500 5400 6300 4500 5400 6300 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2125 2550 2975 2125 2550 2975 2125 2550 2975 174.1 179.7 184.2 185.7 191.0 194.9 197.9 203.3 207.2 51.0 52.7 54.0 54.4 56.0 57.1 58.0 59.6 60.7 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 10.78 .71 10.93 .74 11.03 .78 11.08 .56 11.21 .58 11.32 .60 11.40 .43 11.54 .43 11.65 .44 80_F 27_C .84 .89 .94 .68 .72 .75 .54 .56 .58 85_F 29_C .96 1.00 1.00 .80 .86 .91 .65 .69 .73 Total Cooling Capacity kBtuh 168.8 174.0 178.5 179.9 184.8 188.5 191.8 196.7 200.3 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 49.5 11.95 .71 51.0 12.09 .75 52.3 12.20 .79 52.7 12.23 .56 54.2 12.38 .58 55.2 12.47 .61 56.2 12.55 .43 57.6 12.70 .43 58.7 12.80 .44 80_F 27_C .85 .91 .96 .69 .73 .77 .54 .57 .59 85_F 29_C .98 1.00 1.00 .82 .87 .93 .66 .70 .74 Total Cooling Capacity kBtuh kW 163.1 168.2 172.3 173.8 178.3 181.8 185.1 189.8 193.3 47.8 49.3 50.5 50.9 52.3 53.3 54.2 55.6 56.7 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 13.28 .72 13.42 .76 13.54 .81 13.57 .57 13.70 .59 13.81 .61 13.90 .43 14.06 .44 14.14 .45 80_F 27_C .87 .92 .98 .70 .74 .78 .55 .58 .60 85_F 29_C .99 1.00 1.00 .83 .89 .95 .67 .71 .76 Total Cooling Capacity kBtuh kW 157.1 162.0 166.0 167.3 171.6 174.8 178.2 182.6 185.7 46.0 47.5 48.6 49.0 50.3 51.2 52.2 53.5 54.4 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 14.81 .73 .88 1.00 14.94 .78 .94 1.00 15.08 .82 .99 1.00 15.12 .57 .71 .85 15.24 .60 .75 .91 15.36 .62 .80 .96 15.47 .43 .56 .68 15.59 .44 .58 .73 15.71 .45 .61 .77 30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − THREE COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6750 8400 10050 6750 8400 10050 6750 8400 10050 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3185 3965 4745 3185 3965 4745 3185 3965 4745 258.7 267.6 276.2 273.3 279.9 284.8 290.3 296.7 301.0 75.8 78.4 80.9 80.1 82.0 83.5 85.1 87.0 88.2 75_F (24_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 16.85 .69 17.10 .74 17.34 .82 17.27 .53 17.46 .56 17.60 .59 17.74 .39 17.94 .40 18.06 .41 80_F 27_C .88 .97 1.00 .67 .72 .79 .52 .55 .59 85_F 29_C 1.00 1.00 1.00 .84 .94 .99 .65 .70 .76 Total Cooling Capacity kBtuh 250.6 259.7 268.2 264.7 270.8 275.4 281.0 287.0 291.1 85_F (29_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW 75_F kW Input 24_C 73.4 18.68 .70 76.1 18.92 .76 78.6 19.16 .84 77.6 19.06 .54 79.4 19.24 .57 80.7 19.39 .60 82.4 19.54 .39 84.1 19.73 .40 85.3 19.85 .42 80_F 27_C .90 .98 1.00 .68 .73 .81 .52 .56 .60 85_F 29_C 1.00 1.00 1.00 .86 .96 1.00 .66 .72 .78 Total Cooling Capacity kBtuh kW 242.4 251.6 259.7 255.5 261.4 265.7 271.3 276.6 280.6 71.0 73.7 76.1 74.9 76.6 77.9 79.5 81.1 82.2 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 20.76 .71 21.02 .78 21.27 .86 21.15 .54 21.33 .58 21.48 .61 21.64 .39 21.81 .41 21.94 .42 80_F 27_C .93 .99 1.00 .69 .75 .83 .53 .57 .61 85_F 29_C 1.00 1.00 1.00 .88 .97 1.00 .67 .73 .81 Total Cooling Capacity kBtuh kW 233.7 243.1 251.0 245.8 251.3 255.8 261.0 266.0 269.5 68.5 71.2 73.6 72.0 73.6 75.0 76.5 78.0 79.0 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 23.15 .72 .95 1.00 23.44 .81 1.00 1.00 23.69 .88 1.00 1.00 23.54 .55 .70 .91 23.72 .59 .78 .99 23.86 .63 .86 1.00 24.05 .39 .54 .68 24.22 .41 .58 .75 24.34 .43 .62 .84 30 TON HIGH EFFICIENCY − LGA360H2V (R−22/VAV) − COOLING CAPACITY − FOUR COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Ai Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 9000 11200 13400 9000 11200 13400 9000 11200 13400 85_F (29_C) Total Cooling Capacity L/s kBtuh kW 4250 5285 6325 4250 5285 6325 4250 5285 6325 343.5 356.5 366.8 356.2 363.7 370.1 377.2 383.1 387.1 100.7 104.5 107.5 104.4 106.6 108.5 110.5 112.3 113.4 95_F (35_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 27.98 .70 28.36 .75 28.67 .88 28.35 .53 28.56 .57 28.76 .60 28.96 .37 29.15 .39 29.29 .40 80_F 27_C .97 1.00 1.00 .68 .74 .84 .52 .56 .60 85_F 29_C 1.00 1.00 1.00 .93 1.00 1.00 .67 .73 .81 Total Cooling Capacity kBtuh 331.9 344.5 354.5 342.7 350.1 356.6 362.7 368.2 372.3 Comp Motor kW 75_F kW Input 24_C 97.3 31.20 .71 101.0 31.61 .79 103.9 31.90 .91 100.4 31.55 .53 102.6 31.77 .58 104.5 31.99 .62 106.3 32.18 .37 107.9 32.37 .39 109.1 32.51 .41 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 34 105_F (41_C) Sensible To Total Ratio (S/T) Dry Bulb 80_F 27_C .99 1.00 1.00 .70 .75 .88 .53 .57 .62 85_F 29_C 1.00 1.00 1.00 .96 1.00 1.00 .68 .74 .85 Total Cooling Capacity kBtuh kW 319.7 331.9 341.1 328.8 335.7 342.7 347.6 352.6 356.4 93.7 97.3 100.0 96.4 98.4 100.4 101.9 103.3 104.5 115_F (46_C) Sensible To Total Ratio (S/T) Dry Bulb Comp Motor kW Input 75_F 24_C 34.92 .72 35.32 .84 35.63 .94 35.21 .55 35.49 .59 35.71 .63 35.89 .38 36.07 .40 36.23 .41 80_F 27_C 1.00 1.00 1.00 .71 .80 .92 .54 .59 .63 85_F 29_C 1.00 1.00 1.00 .98 1.00 1.00 .70 .76 .89 Total Cooling Capacity kBtuh kW 307.0 318.6 327.0 314.0 320.8 327.8 331.5 336.3 339.8 90.0 93.4 95.8 92.0 94.0 96.1 97.2 98.6 99.6 Sensible To Total Comp Ratio (S/T) Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 39.18 .74 1.00 1.00 39.59 .88 1.00 1.00 39.93 .98 1.00 1.00 39.42 .56 .73 1.00 39.74 .60 .85 1.00 39.99 .65 .95 1.00 40.10 .38 .55 .71 40.31 .40 .60 .82 40.47 .42 .65 .93 HUMIDITROL® REHEAT OPTION RATINGS 13 TON HIGH EFFICIENCY − LGC156H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature 63_F (17_C) 67_F (19_C) 71_F (22_C) Total Air Volume 65_F (18_C) Total Cooling Capacity cfm L/s kBtuh kW 4200 5200 6200 4200 5200 6200 4200 5200 6200 1980 57.6 16.9 2455 62.2 18.2 2925 65.9 19.3 1980 79.2 23.2 2455 83.3 24.4 2925 86.4 25.3 1980 104.4 30.6 2455 108.7 31.8 2925 111.7 32.7 75_F (24_C) Sensible To Total Ratio (S/T) 85_F (29_C) Sensible To Total Ratio (S/T) 95_F (35_C) Sensible To Total Ratio (S/T) Sensible To Total Total Total Total Ratio (S/T) Comp Comp Comp Comp Cooling Cooling Cooling Motor Capacity Motor Capacity Motor Capacity Motor Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW kW kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW kBtuh kW kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 4.73 0.34 0.62 0.89 50.8 14.9 5.35 0.27 0.60 0.92 44.6 13.1 6.04 0.22 0.60 0.93 36.1 10.6 6.67 0.09 0.55 0.97 4.76 0.45 0.77 1.00 55.2 16.2 5.37 0.42 0.79 1.00 48.8 14.3 6.05 0.38 0.79 1.00 39.9 11.7 6.70 0.32 0.82 1.00 4.78 0.55 0.90 1.00 58.7 17.2 5.39 0.55 0.92 1.00 52.2 15.3 6.07 0.53 0.96 1.00 43.5 12.7 6.72 0.50 0.98 1.00 4.77 0.29 0.44 0.63 72.0 21.1 5.38 0.25 0.42 0.63 65.4 19.1 6.07 0.20 0.40 0.63 57.5 16.8 6.71 0.14 0.36 0.63 4.80 0.34 0.52 0.75 76.0 22.3 5.40 0.30 0.51 0.76 69.1 20.2 6.09 0.27 0.49 0.78 61.0 17.9 6.73 0.22 0.48 0.81 4.81 0.37 0.60 0.87 78.8 23.1 5.42 0.35 0.60 0.88 71.8 21.0 6.11 0.32 0.61 0.91 63.5 18.6 6.75 0.28 0.61 0.95 4.81 0.28 0.40 0.52 95.9 28.1 5.42 0.24 0.37 0.50 88.1 25.8 6.11 0.20 0.34 0.48 78.8 23.1 6.75 0.14 0.30 0.46 4.84 0.29 0.43 0.57 99.9 29.3 5.44 0.26 0.41 0.56 91.8 26.9 6.12 0.22 0.38 0.55 82.3 24.1 6.76 0.17 0.35 0.55 4.86 0.31 0.47 0.63 102.7 30.1 5.46 0.27 0.45 0.64 94.4 27.6 6.14 0.23 0.43 0.64 84.7 24.8 6.78 0.19 0.40 0.64 13 TON HIGH EFFICIENCY − LGC156H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4200 5200 6200 4200 6200 6200 4200 5200 6200 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 1980 2455 2925 1980 2455 2925 1980 2455 2925 111.5 118.4 123.9 136.9 143.1 147.7 166.3 172.7 177.2 32.6 34.7 36.3 40.1 41.9 43.2 48.7 50.6 51.9 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 7.08 0.53 0.73 0.93 7.12 0.61 0.85 1.00 7.16 0.68 0.94 1.00 7.14 0.41 0.55 0.71 7.19 0.44 0.62 0.81 7.20 0.48 0.68 0.90 7.20 0.34 0.46 0.58 7.25 0.35 0.49 0.63 7.28 0.36 0.53 0.69 75_F (24_C) Total Cooling Capacity kBtuh kW 103.3 109.8 115.2 128.1 134.0 138.3 156.0 162.0 166.2 30.2 32.2 33.7 37.5 39.2 40.5 45.7 47.4 48.7 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.01 0.50 0.73 0.95 8.04 0.60 0.87 1.00 8.07 0.70 0.96 1.00 8.06 0.39 0.55 0.71 8.09 0.44 0.61 0.82 8.12 0.48 0.69 0.92 8.12 0.32 0.44 0.57 8.15 0.33 0.48 0.64 8.18 0.34 0.51 0.69 85_F (29_C) Total Cooling Capacity kBtuh kW 95.4 101.7 106.9 119.7 125.2 129.2 146.2 151.8 155.6 27.9 29.8 31.3 35.0 36.7 37.8 42.8 44.4 45.6 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.04 0.50 0.75 0.97 9.06 0.60 0.88 1.00 9.09 0.70 0.98 1.00 9.09 0.37 0.54 0.72 9.12 0.42 0.62 0.84 9.14 0.46 0.70 0.95 9.15 0.29 0.43 0.56 9.17 0.31 0.47 0.64 9.19 0.32 0.51 0.70 95_F (35_C) Total Cooling Capacity kBtuh kW 85.1 90.9 96.3 109.8 115.0 118.7 134.8 140.0 143.6 24.9 26.6 28.2 32.2 33.7 34.8 39.5 41.0 42.0 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 10.05 0.47 0.74 1.00 10.09 0.58 0.90 1.00 10.12 0.71 1.00 1.00 10.11 0.35 0.53 0.73 10.14 0.40 0.61 0.86 10.17 0.45 0.71 0.97 10.17 0.26 0.41 0.56 10.19 0.28 0.46 0.63 10.21 0.31 0.50 0.71 15 TON HIGH EFFICIENCY − LGC180H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 66.6 71.8 75.8 92.2 96.9 100.2 119.4 124.1 127.4 19.5 21.0 22.2 27.0 28.4 29.4 35.0 36.4 37.3 Sensible To Total Ratio (S/T) 75_F (24_C) Total Cooling Capacity Sensible To Total Ratio (S/T) Comp Comp Motor Motor Dry Bulb Dry Bulb kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 5.91 0.34 0.61 0.86 58.0 17.0 6.63 0.27 0.59 0.89 5.95 0.44 0.76 1.00 62.9 18.4 6.67 0.40 0.75 1.00 5.99 0.55 0.89 1.00 66.9 19.6 6.70 0.54 0.90 1.00 5.97 0.29 0.45 0.64 82.2 24.1 6.69 0.22 0.42 0.63 6.01 0.33 0.53 0.75 86.6 25.4 6.73 0.28 0.51 0.76 6.05 0.38 0.61 0.86 89.9 26.3 6.76 0.34 0.59 0.87 6.05 0.26 0.39 0.52 110.1 32.3 6.77 0.23 0.37 0.51 6.09 0.27 0.43 0.57 114.6 33.6 6.82 0.23 0.40 0.57 6.12 0.28 0.47 0.64 117.7 34.5 6.84 0.25 0.44 0.64 85_F (29_C) Total Cooling Capacity kBtuh kW 45.1 49.9 53.7 74.9 79.1 82.2 102.7 106.9 109.8 13.2 14.6 15.7 22.0 23.2 24.1 30.1 31.3 32.2 Sensible To Total Ratio (S/T) 95_F (35_C) Sensible To Total Ratio (S/T) Comp Comp Motor Motor Dry Bulb Dry Bulb kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 7.42 0.11 0.52 0.89 39.0 11.4 8.14 0.04 0.52 0.94 7.44 0.32 0.75 1.00 43.6 12.8 8.18 0.27 0.78 1.00 7.48 0.47 0.93 1.00 47.4 13.9 8.21 0.47 0.95 1.00 7.48 0.19 0.40 0.62 66.5 19.5 8.21 0.12 0.36 0.63 7.52 0.24 0.50 0.76 70.5 20.7 8.24 0.20 0.47 0.78 7.54 0.30 0.60 0.88 73.4 21.5 8.28 0.27 0.59 0.91 7.56 0.20 0.34 0.49 91.9 26.9 8.29 0.13 0.31 0.46 7.60 0.22 0.39 0.56 95.9 28.1 8.32 0.16 0.36 0.56 7.62 0.24 0.43 0.64 98.6 28.9 8.35 0.18 0.41 0.65 Total Cooling Capacity 15 TON HIGH EFFICIENCY − LGC180H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 4800 6000 7200 4800 6000 7200 4800 6000 7200 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2265 2830 3400 2265 2830 3400 2265 2830 3400 126.3 133.9 139.8 155.9 162.7 167.6 187.3 194.3 199.2 37.01 39.2 41.0 45.7 47.7 49.1 54.9 56.9 58.4 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.87 0.51 0.70 0.90 8.93 0.58 0.81 1.00 8.98 0.65 0.91 1.00 8.96 0.39 0.54 0.70 9.02 0.43 0.60 0.80 9.08 0.47 0.67 0.89 9.08 0.31 0.44 0.57 9.14 0.33 0.48 0.61 9.19 0.34 0.51 0.67 75_F (24_C) Total Cooling Capacity kBtuh kW 116.0 123.3 129.2 144.2 150.6 155.3 176.2 182.8 187.3 34.0 36.1 37.9 42.3 44.1 45.5 51.6 53.6 54.9 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.95 0.50 0.70 0.92 10.01 0.57 0.83 1.00 10.05 0.67 0.92 1.00 10.04 0.36 0.53 0.70 10.10 0.41 0.60 0.80 10.15 0.46 0.67 0.89 10.16 0.29 0.43 0.56 10.23 0.31 0.46 0.61 10.27 0.32 0.50 0.68 85_F (29_C) Total Cooling Capacity kBtuh kW 101.3 108.3 113.9 134.8 141.0 145.4 166.6 172.7 177.0 29.7 31.7 33.4 39.5 41.3 42.6 48.8 50.6 51.9 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.16 0.44 0.70 0.93 11.20 0.54 0.83 1.00 11.26 0.65 0.95 1.00 11.25 0.36 0.52 0.71 11.31 0.39 0.60 0.82 11.35 0.44 0.67 0.92 11.37 0.27 0.42 0.55 11.44 0.29 0.46 0.63 11.47 0.32 0.50 0.69 95_F (35_C) Total Cooling Capacity kBtuh kW 93.3 100.0 105.6 124.3 130.1 134.4 153.6 159.4 163.4 27.3 29.3 30.9 36.4 38.1 39.4 45.0 46.7 47.9 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.36 0.43 0.71 0.96 12.42 0.56 0.86 1.00 12.47 0.67 0.97 1.00 12.47 0.33 0.52 0.71 12.52 0.38 0.60 0.83 12.58 0.43 0.69 0.93 12.59 0.25 0.39 0.54 12.64 0.27 0.45 0.62 12.69 0.29 0.49 0.70 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 35 HUMIDITROL® REHEAT OPTION RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 17.5 TON HIGH EFFICIENCY − LGC210H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature 63_F (17_C) 67_F (19_C) 71_F (22_C) Total Air Volume 65_F (18_C) Total Cooling Capacity cfm L/s kBtuh kW 5600 7000 8400 5600 7000 8400 5600 7000 8400 2645 45.2 13.2 3305 50.0 14.6 3965 53.6 15.7 2645 68.6 20.1 3305 72.8 21.3 3965 75.8 22.2 2645 97.8 28.6 3305 102.0 29.9 3965 104.8 30.7 Sensible To Total Ratio (S/T) 75_F (24_C) Sensible To Total Ratio (S/T) 85_F (29_C) Total Cooling Capacity Sensible To Total Ratio (S/T) 95_F (35_C) Sensible To Total Ratio (S/T) Comp Comp Comp Comp Motor Motor Motor Motor Dry Bulb Dry Bulb Dry Bulb Dry Bulb kW kW kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW kBtuh kW kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 4.94 0.15 0.52 0.90 40.2 11.8 5.37 0.10 0.52 0.95 32.6 9.5 5.84 −0.04 0.50 1.00 23.8 6.7 6.51 −0.33 0.42 1.00 4.98 0.32 0.77 1.00 44.6 13.1 5.39 0.28 0.78 1.00 36.8 10.8 5.88 0.22 0.83 1.00 27.8 8.1 6.54 0.08 0.85 1.00 5.00 0.50 0.93 1.00 48.2 14.1 5.43 0.50 0.98 1.00 40.6 11.9 5.90 0.46 1.00 1.00 32.0 9.4 6.56 0.43 1.00 1.00 5.00 0.17 0.35 0.59 63.2 18.5 5.41 0.12 0.34 0.61 55.4 16.2 5.90 0.05 0.29 0.59 46.2 13.5 6.56 −0.09 0.20 0.57 5.02 0.24 0.47 0.75 67.0 19.6 5.45 0.20 0.46 0.77 59.0 17.3 5.94 0.14 0.43 0.81 49.6 14.5 6.60 0.04 0.39 0.82 5.06 0.30 0.58 0.90 69.8 20.4 5.47 0.28 0.59 0.93 61.6 18.0 5.96 0.21 0.59 0.96 52.0 15.2 6.62 0.12 0.57 1.00 5.06 0.21 0.35 0.49 92.0 26.9 5.49 0.18 0.34 0.49 83.8 24.5 5.96 0.15 0.30 0.47 74.4 21.8 6.62 0.08 0.26 0.44 5.10 0.23 0.39 0.56 95.8 28.1 5.51 0.21 0.39 0.56 87.4 25.6 6.00 0.17 0.37 0.56 77.6 22.7 6.66 0.11 0.33 0.54 5.12 0.25 0.45 0.64 98.4 28.8 5.55 0.24 0.44 0.65 89.8 26.3 6.01 0.19 0.41 0.66 79.8 23.4 6.67 0.13 0.39 0.66 Total Cooling Capacity Total Cooling Capacity 17.5 TON HIGH EFFICIENCY − LGC210H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 5600 7000 8400 5600 7000 8400 5600 7000 8400 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 2645 3305 3965 2645 3305 3965 2645 3305 3965 155.4 164.8 172.2 186.2 194.6 200.6 223.6 232.0 237.6 45.5 48.3 50.4 54.5 57.0 58.7 65.5 67.9 69.6 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 10.02 0.52 0.73 0.94 10.08 0.61 0.86 1.00 10.14 0.70 0.97 1.00 10.12 0.40 0.55 0.71 10.18 0.44 0.61 0.83 10.26 0.48 0.69 0.93 10.26 0.32 0.45 0.57 10.34 0.33 0.49 0.63 10.38 0.34 0.52 0.70 75_F (24_C) Total Cooling Capacity kBtuh kW 147.2 156.0 163.4 177.2 185.0 190.6 214.0 221.6 226.8 43.1 45.7 47.8 51.9 54.2 55.8 62.7 64.9 66.4 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 11.09 0.52 0.75 0.97 11.15 0.62 0.89 1.00 11.21 0.72 0.99 1.00 11.91 0.40 0.55 0.73 11.27 0.44 0.62 0.85 11.31 0.48 0.71 0.95 11.35 0.31 0.44 0.58 11.39 0.32 0.48 0.64 11.45 0.35 0.53 0.71 85_F (29_C) Total Cooling Capacity kBtuh kW 136.1 144.5 152.1 165.7 172.8 178.1 201.6 208.8 213.6 39.9 42.3 44.5 48.5 50.6 52.1 59.0 61.1 62.5 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.29 0.52 0.76 1.00 12.36 0.61 0.91 1.00 12.42 0.72 1.00 1.00 12.40 0.38 0.55 0.73 12.50 0.42 0.63 0.87 12.54 0.48 0.71 0.97 12.54 0.30 0.44 0.58 12.62 0.32 0.48 0.64 12.65 0.33 0.53 0.72 95_F (35_C) Total Cooling Capacity kBtuh kW 123.4 131.5 139.8 152.2 159.0 163.9 187.7 194.2 198.5 36.1 38.5 40.9 44.6 46.6 48.0 55.0 56.9 58.1 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 13.79 0.50 0.77 1.00 13.87 0.62 0.94 1.00 13.90 0.74 1.00 1.00 13.90 0.36 0.54 0.75 13.98 0.41 0.63 0.89 14.02 0.47 0.74 1.00 14.02 0.28 0.42 0.58 14.10 0.29 0.47 0.65 14.13 0.32 0.52 0.74 20 TON HIGH EFFICIENCY − LGA240H − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature 63_F (17_C) 67_F (19_C) 71_F (22_C) Total Air Volume 65_F (18_C) Total Cooling Capacity cfm L/s kBtuh kW 6400 8000 9600 6400 8000 9600 6400 8000 9600 3020 51.6 15.1 3775 56.6 16.6 4530 60.8 17.8 3020 78.6 23.0 3775 83.2 24.4 4530 86.4 25.3 3020 106.6 31.2 3775 111.0 32.5 4530 114.2 33.5 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 6.08 0.09 0.46 0.85 6.14 0.26 0.70 1.00 6.18 0.42 0.89 1.00 6.16 0.14 0.33 0.55 6.22 0.20 0.41 0.72 6.24 0.26 0.54 0.85 6.26 0.16 0.30 0.45 6.30 0.19 0.35 0.51 6.34 0.21 0.39 0.59 75_F (24_C) Total Cooling Capacity kBtuh kW 41.8 46.8 50.8 69.6 73.8 77.0 101.4 105.4 108.4 12.3 13.7 14.9 20.4 21.6 22.6 29.7 30.9 31.8 85_F (29_C) Sensible To Total Ratio (S/T) 95_F (35_C) Sensible To Total Ratio (S/T) Sensible To Total Total Total Ratio (S/T) Comp Comp Comp Cooling Cooling Motor Capacity Motor Capacity Motor Dry Bulb Dry Bulb Dry Bulb kW kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 24_C 27_C 29_C 6.72 −0.06 0.41 0.85 30.8 9.0 7.37 −0.35 0.27 0.88 19.8 5.8 8.13 −0.97 0.01 0.94 6.75 0.15 0.70 1.00 35.6 10.4 7.43 −0.01 0.69 1.00 24.2 7.1 8.19 −0.33 0.66 1.00 6.81 0.38 0.92 1.00 39.6 11.6 7.46 0.29 0.94 1.00 28.4 8.3 8.24 0.13 1.00 1.00 6.79 0.06 0.29 0.53 58.4 17.1 7.44 −0.06 0.18 0.50 46.8 13.7 8.22 −0.28 0.04 0.45 6.85 0.14 0.40 0.73 62.4 18.3 7.50 0.04 0.33 0.73 50.6 14.9 8.27 −0.14 0.26 0.73 6.87 0.21 0.52 0.87 65.4 19.2 7.54 0.12 0.49 0.90 53.4 15.7 8.32 −0.01 0.45 0.93 6.89 0.15 0.30 0.44 91.8 26.9 7.56 0.09 0.25 0.41 84.8 24.8 8.33 0.05 0.23 0.40 6.95 0.17 0.35 0.51 95.6 28.0 7.59 0.12 0.30 0.51 88.6 26.0 8.37 0.08 0.29 0.50 6.96 0.19 0.39 0.59 98.4 28.8 7.65 0.14 0.37 0.60 91.0 26.7 8.41 0.12 0.36 0.61 20 TON HIGH EFFICIENCY − LGA240H − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 6400 8000 9600 6400 8000 9600 6400 8000 9600 65_F (18_C) Total Cooling Capacity L/s kBtuh kW 3020 3775 4530 3020 3775 4530 3020 3775 4530 178.9 189.0 197.4 214.0 223.2 230.0 251.3 260.2 266.3 52.4 55.4 57.9 62.7 65.4 67.4 73.6 76.3 78.0 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 12.22 0.55 0.74 0.94 12.34 0.62 0.86 1.00 12.42 0.71 0.96 1.00 12.40 0.42 0.57 0.72 12.50 0.45 0.64 0.82 12.57 0.49 0.70 0.93 12.58 0.32 0.45 0.58 12.68 0.33 0.49 0.63 12.78 0.35 0.52 0.70 75_F (24_C) Total Cooling Capacity kBtuh kW 165.6 175.4 183.6 201.0 209.8 216.1 241.6 250.0 255.7 48.5 51.4 53.8 58.9 61.5 63.3 70.8 73.3 74.9 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 36 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 13.62 0.54 0.75 0.96 13.73 0.62 0.87 1.00 13.81 0.71 0.97 1.00 13.78 0.40 0.56 0.73 13.89 0.44 0.63 0.85 13.97 0.49 0.72 0.94 13.97 0.32 0.44 0.58 14.09 0.33 0.49 0.64 14.16 0.35 0.53 0.71 85_F (29_C) Total Cooling Capacity kBtuh kW 150.4 160.0 168.0 185.4 193.6 199.5 227.3 235.1 240.6 44.0 46.9 49.2 54.3 56.7 58.5 66.6 68.9 70.5 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 15.19 0.52 0.76 0.98 15.27 0.61 0.89 1.00 15.37 0.71 1.00 1.00 15.34 0.38 0.55 0.74 15.43 0.43 0.64 0.85 15.54 0.48 0.72 0.96 15.54 0.30 0.44 0.58 15.65 0.31 0.48 0.65 15.72 0.33 0.53 0.72 95_F (35_C) Total Cooling Capacity kBtuh kW 135.2 144.2 152.6 169.3 177.0 182.6 215.5 223.0 227.9 39.6 42.3 44.7 49.6 51.9 53.5 63.2 65.4 66.8 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.95 0.51 0.76 1.00 17.05 0.62 0.92 1.00 17.15 0.72 1.00 1.00 17.13 0.35 0.54 0.74 17.21 0.40 0.63 0.87 17.32 0.46 0.73 0.99 17.35 0.29 0.43 0.59 17.43 0.30 0.48 0.66 17.52 0.33 0.53 0.74 HUMIDITROL® REHEAT OPTION RATINGS NOTE − For Temperatures and Capacities not shown in tables, see bulletin Cooling Unit Rating Table Correction Factor Data in Miscellaneous Engineering Data section. 25 TON HIGH EFFICIENCY − LGC300S − COOLING CAPACITY WITH HUMIDITROL ON − TWO COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 65_F (18_C) Sensible To Total Ratio (S/T) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 77.0 82.6 87.2 99.0 103.8 107.2 138.8 143.4 146.6 22.5 24.2 25.5 29.0 30.4 31.4 40.6 42.0 42.9 Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 8.34 .25 .55 .88 8.46 .36 .74 1.00 8.56 .51 .91 1.00 8.52 .17 .35 .55 8.64 .22 .42 .72 8.74 .27 .53 .86 8.76 .23 .35 .47 8.88 .24 .39 .53 8.96 .26 .43 .60 75_F (24_C) Total Cooling Capacity kBtuh kW 62.6 68.0 72.4 90.2 94.8 98.0 122.6 127.2 130.0 18.3 19.9 21.2 26.4 27.8 28.7 35.9 37.2 38.1 85_F (29_C) Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 9.01 .10 .49 .88 9.14 .27 .74 1.00 9.24 .45 .91 1.00 9.20 .12 .30 .56 9.32 .18 .40 .73 9.42 .24 .52 .89 9.46 .15 .30 .43 9.55 .17 .34 .50 9.65 .19 .39 .59 Total Cooling Capacity kBtuh kW 45.0 50.2 54.6 70.0 74.4 77.6 102.4 106.4 109.2 13.2 14.7 16.0 20.5 21.8 22.7 30.0 31.2 32.0 95_F (35_C) Sensible To Total Ratio (S/T) Sensible To Total Ratio (S/T) Comp Comp Motor Motor Dry Bulb Dry Bulb kW kW Input 75_F 80_F 85_F Input 75_F 80_F 85_F kBtuh kW 24_C 27_C 29_C 24_C 27_C 29_C 9.59 −.18 .38 .91 27.0 7.9 10.37 −.85 .10 .95 9.71 .10 .71 1.00 32.0 9.4 10.47 −.27 .69 1.00 9.82 .34 .95 1.00 36.6 10.7 10.60 .13 1.00 1.00 9.78 −.08 .15 .47 50.8 14.9 10.54 −.43 −.10 .38 9.89 0 .30 .71 54.8 16.0 10.65 −.29 .14 .71 9.96 .10 .46 .90 57.8 16.9 10.74 −.17 .38 .92 10.00 .02 .19 .35 82.6 24.2 10.78 −.16 .05 .25 10.11 .04 .24 .44 86.4 25.3 10.88 −.12 .12 .37 10.19 .08 .31 .56 89.2 26.1 10.95 −.08 .20 .52 Total Cooling Capacity 25 TON HIGH EFFICIENCY − LGC300S − COOLING CAPACITY WITH HUMIDITROL ON − ALL COMPRESSORS OPERATING Outdoor Air Temperature Entering Outdoor Coil Entering Wet Bulb Temperature Total Air Volume cfm 63_F (17_C) 67_F (19_C) 71_F (22_C) 8000 10000 12000 8000 10000 12000 8000 10000 12000 65_F (18_C) Sensible To Total Ratio (S/T) Total Cooling Capacity L/s kBtuh kW 3775 4720 5665 3775 4720 5665 3775 4720 5665 238.3 249.9 259.5 269.8 279.9 287.0 320.3 330.0 336.7 69.8 73.2 76.0 79.0 82.0 84.0 93.8 96.6 98.6 Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 16.78 .58 .78 .97 17.03 .65 .88 1.00 17.23 .73 .97 1.00 17.16 .44 .59 .74 17.40 .48 .65 .85 17.59 .52 .72 .94 17.65 .36 .48 .60 17.89 .37 .51 .66 18.05 .38 .55 .73 75_F (24_C) Total Cooling Capacity kBtuh kW 219.1 230.4 239.6 256.0 265.5 272.3 298.7 308.2 314.2 64.2 67.5 70.2 75.0 77.7 79.7 87.5 90.2 92.0 85_F (29_C) Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 18.42 .57 .79 .99 18.69 .66 .91 1.00 18.89 .74 1.00 1.00 18.81 .43 .59 .75 19.05 .47 .65 .86 19.24 .51 .74 .96 19.32 .33 .47 .59 19.52 .34 .50 .66 19.72 .36 .54 .73 Total Cooling Capacity kBtuh kW 196.5 207.4 216.6 230.4 239.4 246.1 272.8 281.3 287.1 57.3 60.7 63.4 67.5 70.1 72.1 79.9 82.4 84.1 95_F (35_C) Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 20.11 .55 .79 1.00 20.35 .65 .93 1.00 20.58 .74 1.00 1.00 20.50 .40 .57 .76 20.74 .44 .64 .88 20.89 .49 .74 .99 20.97 .29 .44 .58 21.20 .31 .49 .65 21.37 .32 .52 .73 Total Cooling Capacity kBtuh kW 173.1 183.7 193.3 205.4 213.9 220.2 246.9 254.9 260.6 50.7 53.8 56.6 60.1 62.6 64.5 72.3 74.6 76.3 Sensible To Total Ratio (S/T) Comp Motor Dry Bulb kW Input 75_F 80_F 85_F 24_C 27_C 29_C 22.16 .53 .81 1.00 22.38 .63 .95 1.00 22.64 .75 1.00 1.00 22.53 .35 .55 .77 22.76 .41 .64 .90 22.94 .46 .74 1.00 23.03 .25 .41 .56 23.25 .26 .47 .66 23.40 .29 .51 .73 HIGH ALTITUDE DERATE Units may be installed at altitudes up to 2000 feet (610 m) above sea level without any modification. At altitudes above 2000 feet (610 m), units must be derated to match gas manifold pressures shown in table below. NOTE − This is the only permissible derate for these units. Natural Gas LPG/Propane Altitude − ft. ft (m) in. w.g. kPa in. w.g. kPa 2001 − 3000 (610 − 915) 3.6 0.90 10.2 2.54 3001 − 4000 (915 − 1220) 3.5 0.87 9.9 2.46 4001 − 5000 (1220 − 1525) 3.4 0.85 9.6 2.39 5001 − 6000 (1525 − 1830) 3.3 0.82 9.4 2.34 6001 − 7000 (1830 − 2135) 3.2 0.80 9.1 2.26 7001 − 8000 (2135 − 2440) 3.1 0.77 8.8 2.19 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 37 BLOWER DATA 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 − Wet indoor coil air resistance of selected unit. 2 − Any factory installed options air resistance (heat section, economizer, etc.) 3 − Any field installed accessories air resistance (duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See pages 41 and 43 for wet coil and option/accessory air resistance data. See page 40 for factory installed drive kit specifications. Air Volume cfm f (L/s) 4000 (1890) 4250 (2005) 4500 (2125) 4750 (2240) 5000 (2360) 5250 (2475) 5500 (2595) 5750 (2715) 6000 (2830) 6250 (2950) 6500 (3065) 6750 (3185) 7000 (3305) 7250 (3420) 7500 (3540) 7750 (3655) 8000 (3775) 8250 (3895) 8500 (4010) 8750 (4130) 9000 (4245) 9250 (4365) 9500 (4485) 9750 (4600) 10000 (4720) 10250 (4835) 10500 (4955) 10750 (5075) 11000 (5190) .40 (100) RPM BHP (kW) 545 0.85 (0.63) 555 0.90 (0.67) 565 1.00 (0.75) 575 1.10 (0.82) 585 1.25 (0.93) 595 1.35 (1.01) 605 1.45 (1.08) 615 1.60 (1.19) 630 1.75 (1.31) 640 1.90 (1.42) 650 2.05 (1.53) 665 2.20 (1.64) 675 2.35 (1.75) 690 2.60 (1.94) 700 2.75 (2.05) 715 3.00 (2.24) 725 3.20 (2.39) 740 3.40 (2.54) 750 3.65 (2.72) 765 3.90 (2.91) 780 4.20 (3.13) 790 4.45 (3.32) 805 4.75 (3.54) 820 5.05 (3.77) 835 5.40 (4.03) 845 5.65 (4.21) 860 6.00 (4.48) 875 6.40 (4.77) 890 6.80 (5.07) .60 (150) RPM BHP (kW) 635 1.10 (0.82) 645 1.25 (0.93) 655 1.35 (1.01) 660 1.45 (1.08) 670 1.60 (1.19) 680 1.70 (1.27) 690 1.85 (1.38) 700 2.00 (1.49) 710 2.15 (1.60) 720 2.35 (1.75) 730 2.50 (1.87) 745 2.70 (2.01) 755 2.90 (2.16) 765 3.10 (2.31) 775 3.30 (2.46) 790 3.55 (2.65) 800 3.80 (2.83) 810 4.00 (2.98) 825 4.30 (3.21) 835 4.55 (3.39) 850 4.85 (3.62) 860 5.15 (3.84) 875 5.45 (4.07) 885 5.75 (4.29) 900 6.15 (4.59) 910 6.45 (4.81) 925 6.85 (5.11) 940 7.25 (5.41) 950 7.60 (5.67) .80 (200) RPM BHP (kW) 715 1.40 (1.04) 725 1.55 (1.16) 730 1.65 (1.23) 740 1.80 (1.34) 750 1.95 (1.45) 755 2.10 (1.57) 765 2.25 (1.68) 775 2.45 (1.83) 785 2.60 (1.94) 795 2.80 (2.09) 805 3.00 (2.24) 815 3.20 (2.39) 825 3.40 (2.54) 835 3.65 (2.72) 845 3.85 (2.87) 855 4.10 (3.06) 865 4.35 (3.25) 880 4.65 (3.47) 890 4.90 (3.66) 900 5.20 (3.88) 910 5.50 (4.10) 925 5.85 (4.36) 935 6.15 (4.59) 950 6.55 (4.89) 960 6.85 (5.11) 970 7.20 (5.37) 985 7.65 (5.71) 1000 8.05 (6.01) 1010 8.45 (6.30) TOTAL STATIC PRESSURE Inches Water Gauge (Pa) 1.00 (250) 1.20 (300) 1.40 (350) 1.60 (400) 1.80 (450) 2.00 (495) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP (kW) (kW) (kW) (kW) (kW) (kW) 785 1.70 850 2.00 910 2.30 965 2.60 1020 2.90 1070 3.25 (1.27) (1.49) (1.72) (1.94) (2.16) (2.42) 795 1.85 855 2.15 915 2.45 970 2.80 1025 3.10 1075 3.45 (1.38) (1.60) (1.83) (2.09) (2.31) (2.57) 800 2.00 865 2.35 925 2.65 980 3.00 1030 3.30 1080 3.65 (1.49) (1.75) (1.98) (2.24) (2.46) (2.72) 810 2.15 870 2.50 930 2.85 985 3.20 1040 3.55 1085 3.90 (1.60) (1.87) (2.13) (2.39) (2.65) (2.91) 815 2.30 880 2.70 940 3.05 995 3.40 1045 3.80 1095 4.15 (1.72) (2.01) (2.28) (2.54) (2.83) (3.10) 825 2.50 890 2.90 945 3.25 1000 3.65 1050 4.00 1100 4.40 (1.87) (2.16) (2.42) (2.72) (2.98) (3.28) 835 2.65 895 3.05 955 3.45 1010 3.85 1060 4.25 1110 4.70 (1.98) (2.28) (2.57) (2.87) (3.17) (3.51) 840 2.85 905 3.25 960 3.65 1015 4.10 1065 4.50 1115 4.95 (2.13) (2.42) (2.72) (3.06) (3.36) (3.69) 850 3.05 910 3.45 970 3.90 1025 4.35 1075 4.80 1120 5.20 (2.28) (2.57) (2.91) (3.25) (3.58) (3.88) 860 3.25 920 3.70 975 4.15 1030 4.60 1080 5.05 1130 5.50 (2.42) (2.76) (3.10) (3.43) (3.77) (4.10) 870 3.45 930 3.95 985 4.40 1040 4.85 1090 5.35 1140 5.85 (2.57) (2.95) (3.28) (3.62) (3.99) (4.36) 880 3.70 940 4.20 995 4.65 1045 5.10 1095 5.60 1145 6.10 (2.76) (3.13) (3.47) (3.80) (4.18) (4.55) 890 3.95 950 4.45 1005 4.95 1055 5.40 1105 5.95 1155 6.45 (2.95) (3.32) (3.69) (4.03) (4.44) (4.81) 900 4.15 955 4.65 1015 5.25 1065 5.75 1115 6.25 1160 6.75 (3.10) (3.47) (3.92) (4.29) (4.66) (5.04) 910 4.45 965 4.95 1020 5.50 1075 6.05 1125 6.60 1170 7.15 (3.32) (3.69) (4.10) (4.51) (4.92) (5.33) 920 4.70 975 5.25 1030 5.80 1080 6.35 1130 6.90 1180 7.50 (3.51) (3.92) (4.33) (4.74) (5.15) (5.60) 930 4.95 985 5.50 1040 6.10 1090 6.70 1140 7.25 1185 7.85 (3.69) (4.10) (4.55) (5.00) (5.41) (5.86) 940 5.25 995 5.85 1050 6.45 1100 7.05 1150 7.65 1195 8.25 (3.92) (4.36) (4.81) (5.26) (5.71) (6.15) 950 5.55 1005 6.15 1060 6.80 1110 7.40 1160 8.05 1205 8.65 (4.14) (4.59) (5.07) (5.52) (6.01) (6.45) 960 5.85 1015 6.45 1070 7.15 1120 7.75 1165 8.35 1215 9.05 (4.36) (4.81) (5.33) (5.78) (6.23) (6.75) 970 6.15 1025 6.80 1080 7.50 1130 8.15 1175 8.75 1220 9.40 (4.59) (5.07) (5.60) (6.08) (6.53) (7.01) 985 6.55 1040 7.20 1090 7.85 1140 8.55 1185 9.20 1230 9.85 (4.89) (5.37) (5.86) (6.38) (6.86) (7.35) 995 6.90 1050 7.60 1100 8.25 1150 8.95 1195 9.60 1240 10.30 (5.15) (5.67) (6.15) (6.68) (7.16) (7.68) 1005 7.20 1060 7.95 1110 8.65 1160 9.40 1205 10.05 1250 10.80 (5.37) (5.93) (6.45) (7.01) (7.50) (8.06) 1015 7.60 1070 8.35 1120 9.05 1170 9.80 1215 10.50 1260 11.25 (5.67) (6.23) (6.75) (7.31) (7.83) (8.39) 1030 8.00 1080 8.75 1135 9.55 1180 10.25 1225 11.00 −−− (5.97) (6.53) (7.12) (7.65) (8.21) 1040 8.40 1095 9.20 1145 10.00 1190 10.70 1235 11.45 −−− (6.27) (6.86) (7.46) (7.98) (8.54) 1055 8.85 1105 9.65 1155 10.45 1200 11.20 −−− −−− (6.60) (7.20) (7.80) (8.36) 1065 9.30 1115 10.05 1165 10.90 −−− −−− −−− (6.94) (7.50) (8.13) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 38 2.20 (545) RPM BHP (kW) 1115 3.55 (2.65) 1120 3.75 (2.80) 1130 4.05 (3.02) 1135 4.25 (3.17) 1140 4.50 (3.36) 1150 4.80 (3.58) 1155 5.10 (3.80) 1160 5.35 (3.99) 1170 5.65 (4.21) 1175 5.95 (4.44) 1185 6.30 (4.70) 1190 6.60 (4.92) 1200 6.95 (5.18) 1205 7.30 (5.45) 1215 7.65 (5.71) 1225 8.05 (6.01) 1230 8.40 (6.27) 1240 8.85 (6.60) 1250 9.25 (6.90) 1255 9.65 (7.20) 1265 10.10 (7.53) 1275 10.55 (7.87) 1285 11.05 (8.24) 1295 11.50 (8.58) 2.40 (595) RPM BHP (kW) 1160 3.85 (2.87) 1165 4.10 (3.06) 1175 4.35 (3.25) 1180 4.65 (3.47) 1185 4.90 (3.66) 1195 5.20 (3.88) 1200 5.50 (4.10) 1205 5.80 (4.33) 1215 6.10 (4.55) 1220 6.45 (4.81) 1225 6.75 (5.04) 1235 7.10 (5.30) 1240 7.45 (5.56) 1250 7.85 (5.86) 1260 8.25 (6.15) 1265 8.60 (6.42) 1275 9.00 (6.71) 1280 9.40 (7.01) 1290 9.85 (7.35) 1300 10.30 (7.68) 1310 10.80 (8.06) 1315 11.20 (8.36) 2.60 (645) RPM BHP (kW) 1205 4.15 (3.10) 1210 4.45 (3.32) 1215 4.70 (3.51) 1225 5.00 (3.73) 1230 5.30 (3.95) 1235 5.60 (4.18) 1240 5.90 (4.40) 1250 6.25 (4.66) 1255 6.55 (4.89) 1265 6.90 (5.15) 1270 7.25 (5.41) 1275 7.60 (5.67) 1285 8.00 (5.97) 1290 8.35 (6.23) 1300 8.75 (6.53) 1305 9.15 (6.83) 1315 9.60 (7.16) 1325 10.05 (7.50) 1330 10.45 (7.80) 1340 10.90 (8.13) 1350 11.40 (8.50) −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− BLOWER DATA 21, 25, and 30 TON (248H, 300H, and 360H) BLOWER TABLE INCLUDES RESISTANCE FOR BASE UNIT ONLY WITH DRY INDOOR COIL & AIR FILTERS IN PLACE. FOR ALL UNITS ADD: 1 − Wet indoor coil air resistance of selected unit. 2 − Any factory installed options air resistance (heat section, economizer, etc.) 3 − Any field installed accessories air resistance ( duct resistance, diffuser, etc.) Then determine from blower table blower motor output and drive required. See pages 42−43 for wet coil and option/accessory air resistance data. See page 40 for factory installed drive kit specifications. BOLD INDICATES FIELD FURNISHED DRIVE Air Volume cfm f (L/s) TOTAL STATIC PRESSURE Inches Water Gauge (Pa) .20 (50) .40 (100) .60 (150) .80 (200) 1.00 (250) 1.20 (300) 1.40 (350) 1.60 (400) 1.80 (450) 2.00 (495) 2.20 (545) 2.40 (595) 2.60 (645) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW) 6000 (2830) --- 435 1.20 525 1.45 570 1.60 630 2.00 700 2.35 750 2.80 795 3.15 840 3.40 880 3.80 920 4.20 960 4.65 995 5.10 (0.90) (1.08) (1.19) (1.49) (1.75) (2.09) (2.35) (2.54) (2.83) (3.13) (3.47) (3.80) 6500 (3065) --- 445 1.30 530 1.60 580 1.80 640 2.20 705 2.60 755 3.05 800 3.40 845 3.70 885 4.15 925 4.60 965 5.00 1000 5.45 (0.97) (1.19) (1.34) (1.64) (1.94) (2.28) (2.54) (2.76) (3.10) (4.43) (3.73) (4.07) 7000 (3305) --- 455 1.40 535 1.75 590 2.05 650 2.45 710 2.85 760 3.30 805 3.70 850 4.05 890 4.50 930 4.95 970 5.40 1005 5.85 (1.04) (1.31) (1.53) (1.83) (2.13) (2.46) (2.76) (3.02) (3.36) (3.69) (4.03) (4.36) 7500 (3540) 380 1.05 465 1.50 540 1.90 600 2.30 660 2.70 715 3.15 765 3.60 810 4.00 855 4.45 895 4.90 935 5.35 975 5.85 1010 6.30 (0.78) (1.12) (1.42) (1.72) (2.01) (2.35) (2.69) (2.98) (3.32) (3.66) (3.99) (4.36) (4.70) 8000 (3775) 390 1.25 475 1.65 545 2.10 610 2.55 665 2.95 720 3.45 770 3.90 815 4.35 860 4.85 900 5.30 940 5.75 980 6.30 1015 6.75 (0.93) (1.23) (1.57) (1.90) (2.20) (2.57) (2.91) (3.25) (3.62) (3.95) (4.29) (4.70) (5.04) 8500 (4010) 405 1.40 485 1.90 555 2.35 620 2.80 675 3.30 725 3.75 775 4.20 820 4.70 865 5.20 905 5.70 945 6.20 985 6.75 1020 7.25 (1.04) (1.42) (1.75) (2.09) (2.46) (2.80) (3.13) (3.51) (3.88) (4.25) (4.63) (5.04) (5.41) 9000 (4245) 415 1.60 495 2.10 565 2.60 625 3.10 685 3.60 735 4.10 785 4.60 830 5.10 870 5.60 915 6.15 955 6.70 990 7.20 1025 7.70 (1.19) (1.57) (1.94) (2.31) (2.69) (3.06) (3.43) (3.80) (4.18) (4.59) (5.00) (5.37) (5.74) 9500 (4485) 430 1.85 505 2.35 575 2.90 635 3.40 690 3.90 745 4.50 790 4.95 835 5.50 880 6.05 920 6.60 960 7.15 995 7.70 1035 8.30 (1.38) (1.75) (2.16) (2.54) (2.91) (3.36) (3.69) (4.10) (4.51) (4.92) (5.33) (5.74) (6.19) 10,000 (4720) 445 2.10 520 2.65 585 3.20 645 3.75 700 4.30 750 4.85 800 5.40 845 5.95 885 6.50 925 7.05 965 7.65 1000 8.20 1040 8.85 (1.57) (1.98) (2.39) (2.80) (3.21) (6.49) (4.03) (4.44) (4.85) (5.26) (5.71) (6.12) (6.60) 10,500 4955) 455 2.35 530 2.95 595 3.50 655 4.10 710 4.70 760 5.25 805 5.80 850 6.40 895 7.00 935 7.60 970 8.15 1010 8.80 1045 9.40 (1.75) (2.20) (2.61) (3.06) (3.03) (3.92) (4.33) (4.77) (5.22) (5.67) (608) (6.56) (7.01) 11,000 (5190) 470 2.60 545 3.25 605 3.85 665 4.45 720 5.10 765 5.66 815 6.30 860 6.90 900 7.50 940 8.10 980 8.75 1015 9.35 (1.94) (2.42) (2.87) (3.32) (3.80) (4.22) (4.70) (5.15) (5.60) (6.04) (6.53) (6.98) --- 11,500 (5425) 485 2.95 555 3.60 620 4.25 675 4.85 730 5.55 775 6.10 820 6.70 865 7.40 910 8.05 945 8.65 985 9.30 1020 9.95 (2.20) (2.69) (3.17) (3.62) (4.14) (4.55) (5.00) (5.52) (6.01) (6.45) (6.94) (7.42) --- 12,000 (5665) 500 3.30 570 4.00 630 4.65 685 5.30 740 6.00 785 6.60 830 7.25 875 7.95 915 8.60 955 9.25 995 9.95 1030 10.60 (2.46) (2.98) (3.47) (3.95) (4.480 (4.92) (5.41) (5.93) (6.42) (6.90) (7.42) (7.91) --- 12,500 (5900) 515 3.65 580 4.35 640 5.05 695 5.75 750 6.50 795 7.10 840 7.80 885 8.55 925 9.20 965 9.90 1000 10.55 1035 11.25 (2.72) (3.25) (3.77) (4.29) (4.85) (5.30) (5.82) (6.38) (6.86) (7.39) (7.87) (8.39) --- 13,000 (6135) 530 4.05 595 4.80 655 5.55 710 6.25 760 7.00 805 7.65 850 8.40 890 9.05 930 9.75 970 10.50 1010 11.30 (3.02) (3.58) (4.14) (4.66) (5.22) (5.71) (6.27) (6.75) (7.27) (7.83) (8.43) --- --- 13,500 (6370) 545 4.45 610 5.25 665 6.00 720 6.75 770 7.50 815 8.25 860 9.00 900 9.70 940 10.45 980 11.20 (3.32) (3.92) (4.48) (5.04) (5.60) (6.15) (6.71) (7.24) (7.80) (8.36) --- --- --- 14,000 (6605) 560 4.90 620 5.70 680 6.55 730 7.30 780 8.10 825 8.85 870 9.65 910 10.40 950 11.15 (3.66) (4.25) (4.89) (5.45) (6.04) (6.60) (7.20) 7.76) (8.31) --- --- --- --- 14,500 (6845) 575 5.40 635 6.25 690 7.05 745 7.90 790 8.65 835 9.45 880 10.30 920 11.10 (4.03) (4.66) (5.26) (5.89) (6.45) (7.05) (7.68) (8.28) --- --- --- --- --- 15,000 (7080) 590 5.90 650 6.80 705 7.65 755 8.50 800 9.30 845 10.10 890 11.00 (4.40) (5.07) (5.71) (6.340 (6.94) (7.53) (8.21) --- --- --- --- --- --- L Series Packaged Gas/Electric − 13 to 30 Tons / Page 39 BLOWER DATA CONSTANT AIR VOLUME (CAV) BELT DRIVE KIT SPECIFICATIONS Model No. Motor Efficiency Nominal hp Maximum hp Nominal kW Maximum kW Drive Kit Number RPM Range 156H Standard or High 2 hp 2.3 1.5 1.7 A 535 − 725 156H thru 210 Standard 3 hp 3.45 2.2 2.6 A 1 535 − 725 685 − 865 High 3 hp 3.45 2.2 2.6 2 685 − 865 156H thru 300S Standard or High 5 hp 5.75 3.7 4.3 2 3 4 685 − 865 850 − 1045 945 − 1185 180 thru 300S Standard or High 7.5 hp 8.63 5.6 6.4 5 6 7 945 − 1185 1045 − 1285 850 − 1045 240 thru 300S Standard or High 10 hp 11.5 7.5 8.6 6 8 1045 − 1285 1135 − 1365 248H, 300H, and 360H Standard or High 5 hp 5.75 3.7 4.3 1 2 6 660 − 810 770 − 965 560 − 710 Standard or High 7.5 hp 8.63 5.6 6.4 3 4 715 − 880 770 − 965 Standard or High 10 hp 11.5 7.5 8.6 3 5 715 − 880 850 − 1045 NOTE − Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. Maximum usable output of motors furnished are shown. In Canada, nominal motor output is also maximum usable motor output. If motors of comparable output are used, be sure to keep within the service factor limitations outlined on the motor nameplate. VARIABLE AIR VOLUME (VAV) DRIVE KIT SPECIFICATIONS Model No. 248H, 300H, and 360H Motor Efficiency Nominal hp Nominal kW Drive Kit Number Maximum RPM @ 60Hz VFD Output (Fixed Pulley) Standard or High 5 hp 3.7 7 965 Standard or High 7.5 hp 5.6 8 965 Standard or High 10 hp 7.5 9 1045 NOTE − Using total air volume and system static pressure requirements determine from blower performance tables rpm and motor output required. For VFD applications, nominal motor output is also maximum usable motor output. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 40 BLOWER DATA 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE Air Volume cfm Wet Indoor Coil Humiditrol Gas Heat Exchanger Hot Gas Low/Std. Heat Med. Heat High Heat Reheat Coil 156H,180H, 156H, 210H, 180S/H 240H, 300S 210H, 240H 156 thru 300S 156 thru 300S 180 thru 300S 300S L/s 210S, 240S in. in. in. in. in. in. Pa Pa Pa w.g. w.g. w.g. w.g. Pa w.g. Pa w.g. Pa Horizontal Roof Curb Economizer 156H thru 300S 156H thru 240H in. w.g. in. w.g. Pa Pa MERV 11 Filter 300S in. w.g. Pa in. w.g. Pa 4000 1890 .02 5 .04 10 .02 5 .04 10 .06 15 −−− −−− .06 15 −−− .01 2 4250 2005 .02 5 .04 10 .02 5 .04 10 .06 15 −−− −−− .07 17 −−− .01 2 4500 2125 .02 5 .05 12 .02 5 .05 12 .07 17 .09 22 −−− .07 17 .02 5 .01 2 4750 2240 .02 5 .05 12 .02 5 .05 12 .08 20 .10 25 −−− .08 20 .03 7 .01 2 5000 2360 .02 5 .05 12 .02 5 .05 12 .09 22 .11 27 −−− .08 20 .03 7 .01 2 5250 2475 .02 5 .06 15 .03 7 .06 15 .10 25 .12 30 −−− .09 22 .04 10 .02 5 5500 2595 .02 5 .07 17 .03 7 .06 15 .10 25 .13 32 −−− .10 25 .04 10 .02 5 5750 2715 .03 7 .07 17 .03 7 .06 15 .11 27 .14 35 −−− .11 27 .05 12 .02 5 6000 2830 .03 7 .08 20 .03 7 .07 17 .12 30 .15 37 −−− .11 27 .06 15 .02 5 6250 2950 .03 7 .08 20 .03 7 .07 17 .12 30 .16 40 .01 2 .12 30 .07 17 .02 5 6500 3065 .03 7 .09 22 .04 10 .08 20 .13 32 .17 42 .02 5 .13 32 .08 20 .02 5 6750 3185 .04 10 .10 25 .04 10 .08 20 .14 35 .18 45 .03 7 .14 35 .08 20 .02 5 7000 3305 .04 10 .10 25 .04 10 .09 22 .15 37 .19 47 .04 10 .15 37 .09 22 .03 7 7250 3420 .04 10 .11 27 .04 10 .09 22 .16 40 .20 50 .05 12 .16 40 .10 25 .03 7 7500 3540 .05 12 .12 30 .05 12 .10 25 .17 42 .21 52 .06 15 .17 42 .11 27 .03 7 8000 3775 .05 12 .13 32 .05 12 .11 27 .19 47 .24 60 .09 22 .19 47 .13 32 .04 10 8500 4010 .06 15 .15 37 .05 12 .12 30 .20 50 .26 65 .11 27 .21 52 .15 37 .04 10 9000 4245 .07 17 .16 40 .06 15 .13 32 .23 57 .29 72 .14 35 .24 60 .17 42 .04 10 9500 4485 .08 20 .18 45 .07 17 .14 35 .25 62 .32 80 .16 40 .26 65 .19 47 .05 12 10,000 4720 .08 20 .20 50 .07 17 .16 40 .27 67 .35 87 .19 47 .29 72 .21 52 .06 15 10,500 4955 .09 22 .22 55 .08 20 .17 42 .30 75 .38 94 .22 55 .31 77 .24 60 .06 15 11,000 5190 .11 27 .24 60 .08 20 .18 45 .31 77 .40 99 .25 62 .34 85 .27 67 .07 17 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 41 BLOWER DATA 21, 25, and 30 TON (248H, 300H, and 360H) FACTORY INSTALLED OPTIONS/FIELD INSTALLED ACCESSORY AIR RESISTANCE Air V l Volume Wet Indoor C il Coil Gas Heat Exchanger Standard Heat in. w.g. Pa Medium Heat in. w.g. Pa Economizer Horizontal R f Curb Roof C b MERV 11 Filt Filter High Heat in. w.g. Pa in. w.g. Pa in. w.g. Pa in. w.g. Pa cfm L/s in. w.g. Pa 6000 2830 .04 10 .12 30 .16 40 .19 47 .01 3 .08 20 .01 2 6500 3070 .05 13 .13 32 .18 45 .21 52 .01 3 .09 22 .01 2 7000 3305 .06 15 .14 35 .20 50 .24 59 .02 5 .10 25 .01 2 7500 3540 .07 17 .15 37 .21 52 .25 62 .02 5 .11 27 .02 5 8000 3775 .08 20 .17 42 .24 59 .28 70 .02 5 .13 32 .02 5 8500 4010 .08 20 .20 50 .27 67 .31 77 .03 7 .15 37 .02 5 9000 4245 .09 22 .22 55 .29 72 .34 85 .04 10 .17 42 .02 5 9500 4485 .10 25 .24 60 .32 80 .38 94 .04 10 .19 47 .03 7 10,000 4720 .11 27 .27 67 .36 90 .42 104 .05 12 .21 52 .03 7 10,500 4955 .12 30 .30 75 .40 99 .46 114 .06 15 .24 60 .03 7 11,000 5190 .12 30 .33 92 .43 107 .50 137 .07 17 .27 67 .04 10 11,500 5425 .13 32 .37 92 .48 119 .55 137 .08 20 .30 75 .04 10 12,000 5665 .14 35 .40 99 .52 129 .60 149 .10 25 .33 82 .04 10 12,500 5900 .15 37 .44 109 .57 142 .65 162 .11 27 .37 92 .05 12 13,000 6135 .16 40 .48 119 .61 152 .70 174 .13 32 .40 99 .05 12 13,500 6370 .17 42 .53 132 .67 167 .76 189 .14 35 .44 109 .06 15 14,000 6605 .18 45 .57 142 .72 179 .82 204 .16 40 .49 122 .06 15 14,500 6845 .19 47 .62 154 .78 194 .89 221 .18 45 .53 132 .06 15 15,000 7080 .20 50 .68 169 .84 209 .95 236 .21 52 .58 144 .07 17 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 42 BLOWER DATA CEILING DIFFUSER AIR RESISTANCE Step-Down Diffuser RTD11−185 Air Volume 2 Ends Open 1 Side/2 Ends Open Flush Diffuser RTD11−275 All Ends & Sides Open 2 Ends Open 1 Side/2 Ends Open LARTD30/36 All Ends & Sides Open 2 Ends Open 1 Side/2 Ends Open All Ends FD11−185 FD11−275 LAFD30/36 & Sides Open in. in. in. in. in. in. in. in. in. in. Pa Pa Pa Pa Pa Pa Pa Pa Pa Pa w.g. w.g. w.g. w.g. w.g. w.g. w.g. w.g. w.g. w.g. in. Pa w.g. in. w.g. Pa 67 −−− −−− −−− −−− .30 75 −−− −−− −−− −−− 112 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .33 82 −−− −−− −−− −−− .48 119 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .36 90 −−− −−− −−− −−− 147 .51 127 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .39 97 −−− −−− −−− −−− .63 157 .55 137 .42 104 .29 72 −−− −−− 199 .68 169 .59 147 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .46 114 − − − − − − −−− −−− 214 .72 179 .63 157 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .50 124 − − − − − − −−− −−− 85 −−− −−− 167 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .54 134 − − − − − − −−− −−− .72 174 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .58 144 − − − − − − −−− −−− 216 .76 189 .62 154 99 −−− −−− .92 229 .80 199 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .66 164 − − − − − − −−− −−− .97 241 .84 209 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .70 174 − − − − − − −−− −−− −−− −−− .45 112 .29 72 .74 184 − − − − − − −−− −−− 72 −−− −−− .50 124 .34 85 .34 85 −−− −−− .57 142 .39 97 117 .39 97 −−− −−− .66 164 .44 109 .53 132 .45 112 − − − − − − .74 184 .51 127 174 .60 149 .51 127 − − − − − − .81 201 .57 142 .78 194 .68 169 .58 144 − − − − − − .89 221 .65 162 219 .87 216 .76 190 .65 162 − − − − − − .96 239 .72 179 11,500 5425 −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− .97 241 .85 211 .73 182 − − − − − − − − − − − − .81 201 12,000 5665 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.08 269 .94 234 .82 204 − − − − − − − − − − − − .90 223 12,500 5900 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.19 296 1.04 259 .91 226 − − − − − − − − − − − − .99 246 13,000 6135 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.30 323 1.15 286 1.00 249 − − − − − − − − − − − − 1.10 274 13,500 6370 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.43 356 1.26 313 1.10 374 − − − − − − − − − − − − 1.20 298 14,000 6605 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.56 388 1.38 343 1.20 298 − − − − − − − − − − − − 1.31 326 14,500 6845 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.69 420 1.50 373 1.31 326 − − − − − − − − − − − − 1.43 356 15,000 7080 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 1.84 457 1.63 405 1.43 356 − − − − − − − − − − − − 1.56 388 cfm L/s 5000 2360 .51 127 .44 109 .39 97 −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− .27 5200 2455 .56 139 .48 119 .42 104 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − 5400 2550 .61 152 .52 129 .45 5600 2645 .66 164 .56 139 5800 2735 .71 177 .59 6000 2830 .76 189 6200 2925 .80 6400 3020 .86 6500 3065 −−− −−− −−− −−− −−− −−− 6600 3115 .92 229 .77 191 .67 6800 3210 .99 246 .83 206 7000 3305 1.03 256 .87 7200 3400 1.09 271 7400 3490 1.15 286 7500 3540 7600 3585 1.20 301 1.02 254 8000 3775 −−− −−− −−− −−− −−− −−− .59 147 .49 122 .43 107 .42 104 .36 90 .29 8500 4010 −−− −−− −−− −−− −−− −−− .69 172 .58 144 .50 124 .48 119 .41 102 9000 4245 −−− −−− −−− −−− −−− −−− .79 196 .67 167 .58 144 .55 137 .47 9500 4485 −−− −−− −−− −−− −−− −−− .89 221 .75 186 .65 162 .62 154 10,000 4720 − − − − − − − − − − − − − − − − − − 1.00 249 .84 209 .73 182 .70 10,500 4955 − − − − − − − − − − − − − − − − − − 1.10 273 .92 229 .80 199 11,000 5190 − − − − − − − − − − − − − − − − − − 1.21 301 1.01 251 .88 −−− −−− −−− −−− −−− −−− .88 .36 .42 .49 .51 90 104 122 127 .31 .36 .41 .46 77 90 102 114 .27 .31 .36 .41 67 77 90 102 −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− .37 92 .31 77 .25 62 219 − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − − .34 .40 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 43 BLOWER DATA POWER EXHAUST FANS 50% HIGH STATIC OPERATION BOLD INDICATES FIELD FURNISHED DRIVE Air Volume f cfm (L/s) Return Duct Negative Static Pressure − Inches Water Gauge (Pa) 0 (0) RPM .10 (25) BHP RPM (kW) .20 (50) BHP RPM (kW) .30 (75) BHP RPM (kW) .40 (100) BHP RPM (kW) .50 (125) BHP RPM (kW) .60 (150) BHP RPM (kW) .70 (175) BHP RPM (kW) .80 (200) BHP RPM (kW) .90 (225) BHP RPM (kW) 1.0 (250) BHP RPM (kW) BHP (kW) 4000 (1890) 335 0.30 380 (0.22) 0.35 430 (0.26) 0.40 475 (0.30) 0.45 520 (0.34) 0.50 570 (0.37) 0.55 615 (0.41) 0.65 665 (0.48) 0.70 710 (0.52) 0.75 755 (0.56) 0.85 (0.63) 4500 (2125) 375 0.40 415 (0.30) 0.45 460 (0.34) 0.55 500 (0.41) 0.60 545 (0.45) 0.65 585 (0.48) 0.70 625 (0.52) 0.80 670 (0.60) 0.85 710 (0.63) 0.95 750 (0.71) 1.00 795 (0.75) 1.10 (0.82) 5000 (2360) 415 0.55 455 (0.41) 0.65 490 (0.48) 0.70 530 (0.52) 0.75 570 (0.56) 0.85 605 (0.63) 0.90 645 (0.67) 1.00 680 (0.75) 1.05 720 (0.78) 1.15 755 (0.86) 1.20 795 (0.90) 1.30 (0.97) 5500 (2595) 460 0.75 495 (0.56) 0.85 525 (0.63) 0.90 560 (0.67) 0.95 595 (0.71) 1.05 630 (0.78) 1.10 665 (0.82) 1.20 700 (0.90) 1.30 735 (0.97) 1.35 765 (1.01) 1.45 800 (1.08) 1.55 (1.16) 6000 (2830) 500 1.00 530 (0.75) 1.05 565 (0.78) 1.15 595 (0.86) 1.20 625 (0.90) 1.30 660 (0.97) 1.40 690 (1.04) 1.45 720 (1.08) 1.55 750 (1.16) 1.65 785 (1.23) 1.70 815 (1.27) 1.80 (1.34) 6500 (3065) 540 1.25 570 (0.93) 1.30 600 (0.97) 1.40 630 (1.04) 1.50 660 (1.12) 1.60 685 (1.19) 1.65 715 (1.23) 1.75 745 (1.31) 1.85 775 (1.38) 1.95 805 (1.45) 2.05 830 (1.53) 2.10 (1.57) 7000 (3305) 585 1.55 610 (1.16) 1.65 635 (1.23) 1.70 665 (1.27) 1.85 690 (1.38) 1.90 720 (1.42) 2.00 745 (1.49) 2.10 770 (1.57) 2.20 800 (1.64) 2.30 825 (1.72) 2.40 855 (1.79) 2.50 (1.87) 7500 (3540) 625 1.90 650 (1.42) 2.00 675 (1.49) 2.10 700 (1.57) 2.20 725 (1.64) 2.30 750 (1.72) 2.40 775 (1.79) 2.50 800 (1.87) 2.60 825 (1.94) 2.70 850 (2.01) 2.80 875 (2.09) 2.90 (2.16) 8000 (3775) 665 2.30 690 (1.72) 2.40 715 (1.79) 2.55 735 (1.90) 2.60 760 (1.94) 2.70 785 (2.01) 2.85 810 (2.13) 2.95 830 (2.20) 3.05 855 (2.28) 3.15 880 (2.35) 3.25 905 (2.42) 3.40 (2.54) 8500 (4010) 710 2.80 730 (2.09) 2.90 755 (2.16) 3.00 775 (2.24) 3.10 795 (2.31) 3.20 820 (2.39) 3.35 840 (2.50) 3.45 865 (2.57) 3.55 885 (2.65) 3.65 910 (2.72) 3.80 930 (2.83) 3.90 (2.91) −−− POWER EXHAUST FANS 100% HIGH STATIC OPERATION BOLD INDICATES FIELD FURNISHED DRIVE Air Volume cfm f (L/s) 8500 (4010) 9000 (4245) 9500 (4485) 10,000 (4720) 10,500 (4955) 11,000 (5190) 11,500 (5425) 12,000 (5665) 12,500 (5900) 13,000 (6135) 13,500 (6370) 14,000 (6605) Return Duct Negative Static Pressure − Inches Water Gauge (Pa) 0 (0) RPM .10 (25) BHP RPM (kW) .20 (50) BHP RPM (kW) .30 (75) BHP RPM (kW) .40 (100) BHP RPM (kW) .50 (125) BHP RPM (kW) .60 (150) BHP RPM (kW) .70 (175) BHP RPM (kW) .80 (200) BHP RPM (kW) .90 (225) BHP RPM (kW) 1.0 (250) BHP RPM (kW) BHP (kW) 475 1.30 500 (0.97) 1.30 525 (0.97) 1.40 550 (1.04) 1.50 585 (1.12) 1.60 625 (1.19) 1.75 670 (1.31) 1.90 710 (1.42) 2.10 745 (1.57) 2.30 780 (1.72) 2.50 815 (1.87) 2.70 (2.01) 520 1.55 535 (1.16) 1.60 550 (1.19) 1.65 570 (1.23) 1.70 605 (1.27) 1.85 640 (1.38) 1.95 685 (1.45) 2.15 720 (1.60) 2.35 760 (1.75) 2.55 790 (1.90) 2.75 825 (2.05) 3.00 (2.24) 550 1.80 560 (1.34) 1.85 575 (1.38) 1.90 600 (1.42) 2.00 620 (1.49) 2.10 655 (1.57) 2.20 695 (1.64) 2.40 735 (1.79) 2.60 770 (1.94) 2.80 800 (2.09) 3.00 835 (2.24) 3.25 (2.42) 575 2.10 590 (1.57) 2.15 605 (1.60) 2.20 620 (1.64) 2.30 645 (1.72) 2.40 675 (1.79) 2.50 710 (1.87) 2.65 745 (1.98) 2.85 780 (2.13) 3.05 815 (2.28) 3.30 845 (2.46) 3.50 (2.61) 605 2.45 615 (1.83) 2.45 625 (1.83) 2.50 645 (1.87) 2.60 670 (1.94) 2.75 690 (2.05) 2.80 725 (2.09) 3.00 755 (2.24) 3.15 790 (2.35) 3.35 825 (2.50) 3.60 855 (2.69) 3.80 (2.83) 630 2.80 645 (2.09) 2.85 660 (2.13) 2.95 675 (2.20) 3.00 685 (2.24) 3.05 715 (2.28) 3.20 740 (2.39) 3.30 770 (2.46) 3.50 805 (2.61) 3.70 835 (2.76) 3.90 870 (2.91) 4.20 (3.13) 665 3.25 675 (2.42) 3.30 680 (2.46) 3.30 695 (2.46) 3.40 715 (2.54) 3.50 735 (2.61) 3.60 755 (2.69) 3.70 785 (2.76) 3.85 815 (2.87) 4.05 850 (3.02) 4.30 880 (3.21) 4.50 (3.36) 685 3.60 700 (2.69) 3.70 710 (2.76) 3.75 725 (2.80) 3.85 740 (2.87) 3.95 755 (2.95) 4.00 780 (2.98) 4.15 805 (3.10) 4.30 830 (3.21) 4.45 860 (3.32) 4.65 890 (3.47) 4.90 (3.66) 720 4.10 730 (3.06) 4.20 740 (3.13) 4.25 750 (3.17) 4.30 765 (3.21) 4.40 780 (3.28) 4.50 800 (3.36) 4.60 820 (3.43) 4.75 845 (3.54) 4.90 875 (3.66) 5.10 905 (3.80) 5.35 (3.99) 745 4.60 750 (3.43) 4.65 765 (3.47) 4.75 780 (3.54) 4.85 790 (3.62) 4.90 805 (3.66) 5.00 820 (3.73) 5.10 840 (3.80) 5.25 865 (3.92) 5.40 890 (4.03) 5.60 915 (4.18) 5.80 (4.33) 775 5.15 785 (3.84) 5.25 795 (3.92) 5.35 805 (3.99) 5.40 815 (4.03) 5.50 830 (4.10) 5.60 845 (4.18) 5.70 865 (4.25) 5.80 880 (4.33) 5.95 905 (4.44) 6.10 930 (4.55) 6.30 (4.70) 805 5.80 810 (4.33) 5.80 820 (4.33) 5.90 830 (4.40) 6.00 845 (4.48) 6.10 855 (4.55) 6.20 870 (4.63) 6.30 885 (4.70) 6.40 905 (4.77) 6.55 925 (4.89) 6.70 945 (5.00) 6.85 (5.11) HIGH STATIC POWER EXHAUST FANS WITH CONSTANT AIR VOLUME − DRIVE KIT SPECIFICATIONS Unit Model No. 248H,, 300H,, and 360H Power Exhaust Fan Model No. LAPEB30/36A (50%) LAPEB30/36B (50%) LAPEB30/36C (50%) LAPEB30/36D (100%) LAPEB30/36E (100%) LAPEB30/36F (100%) Motor HP Drive Kit Number (2) 2 hp (2) 2 hp (2) 2 hp (3) 2 hp (3) 2 hp (3) 2 hp 1 2 3 1 2 3 NOTE − Using total air volume and system static pressure requirements, determine from blower performance tables rpm and required. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 44 RPM Range 406 − 533 531 − 731 731 − 932 406 − 533 531 − 731 731 − 932 BLOWER DATA POWER EXHAUST FANS STANDARD STATIC OPERATION 156H, 180, 210, 240, and 300S Return Duct Air Volume Negative Static Pressure in. w.g. Pa cfm L/s 248H, 300H, and 360H Return Duct Air Volume Negative Static Pressure in. w.g. Pa cfm L/s 0 0 8630 4070 0 0 12,800 6040 0.05 12 8210 3875 0.05 12 12,200 5760 0.10 25 7725 3645 0.10 25 11,500 5430 0.15 37 7110 3355 0.15 37 10,800 5100 0.20 50 6470 3055 0.20 50 9900 4670 0.25 62 5790 2730 0.25 62 9000 4250 0.30 75 5060 2390 0.30 75 7900 3730 0.35 87 4300 2030 0.35 87 6750 3190 0.40 100 3510 1655 0.40 100 5450 2570 0.45 112 2690 1270 0.45 112 4150 1960 0.50 125 1840 870 0.50 125 2900 1370 Model No. Air Volume CEILING DIFFUSER AIR THROW DATA 1 Model No. Air Volume cfm 156H 180 210 240 300S 1 L/s Step-Down ft. 1 Effective Throw Range m Flush ft. cfm m Diffuser Model 5600 2645 5800 2740 6000 2830 6200 2925 6400 3020 6600 3115 RTD11−185 39 − 49 12 − 15 42 − 51 13 − 16 44 − 54 13 − 17 45 − 55 14 − 17 46 − 55 14 − 17 57 − 56 14 − 17 FD11−185 28 − 37 9 − 11 29 − 38 9 − 12 40 − 50 12 − 15 42 − 51 13 − 16 53 − 52 13 − 16 45 − 56 14 − 17 Diffuser Model 7200 3400 7400 3490 7600 3585 7800 3680 3775 8000 8200 3870 8400 3965 8600 4060 8800 4155 RTD11−275 33 − 38 10 − 12 35 − 40 11 − 12 36 − 41 11 − 13 38 − 43 11 − 13 39 − 44 12 − 13 41 − 46 12 − 14 43 − 49 13 − 15 44 − 50 13 − 15 47 − 55 14 − 17 FD11−275 26 − 35 8 − 11 28 − 37 9 − 11 29 − 38 9 − 12 40 − 50 12 − 15 42 − 51 13 − 16 43 − 52 13 − 16 44 − 54 13 − 17 46 − 57 14 − 17 48 − 59 15 − 18 Throw is the horizontal or vertical distance an airstream travels on leaving the outletor diffuser before the maximum velocity is reduced to 50 ft. (15 m) per minute. Four sides open. L/s Diffuser Model 248H 300H 360H Effective Throw Range Step-Down ft. m LARTD30/36 Flush ft. m LAFD30/36 9000 4245 40 − 47 12 − 14 29 − 35 8 − 11 9500 4485 43 − 50 13 − 15 33 − 41 10 − 12 10,000 4720 46 − 54 14 − 16 37 − 46 11 − 14 10,500 4955 50 − 58 15 − 18 42 − 51 13 − 15 11,000 4190 53 − 61 16 − 19 46 − 56 14 − 17 11,500 5425 55 − 64 17 − 20 50 − 61 15 − 19 12,000 5665 58 − 67 18 − 20 54 − 66 16 − 20 12,500 5900 61 − 71 19 − 22 58 − 71 18 − 22 13,000 6135 64 − 74 20 − 23 62 − 75 19 − 23 13,500 6370 67 − 77 20 − 23 66 − 79 20 − 24 1 Throw is the horizontal or vertical distance an airstream travels on leaving the outletor diffuser before the maximum velocity is reduced to 50 ft. (15 m) per minute. Four sides open. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 45 OPTIONAL DISCONNECT SWITCH REQUIREMENTS Model No No. 156H 180 210 240 248 300 360 Voltage Blower Motor hp 208/230v−3ph 208/230v−3ph 460v−3ph 575v−3ph 208/230v−3ph 460v−3ph 575v−3ph 208/230v−3ph 460v−3ph 575v−3ph 208/230v−3ph 460v−3ph 575v−3ph 2, 3 5 2, 3, 5 2, 3, 5 3, 5, 7.5 3, 5, 7.5 3, 5, 7.5 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 5, 7.5, 10 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 46 Disconnect Switch 80A 30M39 −−− 30M39 30M39 −−− 30M39 30M39 −−− 30M39 30M39 −−− 30M39 30M39 150A −−− 30M40 −−− −−− 30M40 −−− −−− 30M40 −−− −−− −−− −−− −−− 250A −−− −−− −−− −−− −−− −−− −−− −−− −−− −−− 30M41 −−− −−− ELECTRICAL DATA 13 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((3)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t (4) FanMotors Lockedrotoramps each(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti ((amps)) Protection No PEF 2 Minimum Circuit With Standard PEF A Ampacity it No PEF (Number)Horsepower (W) Optional p Standard St ti Power Static P Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) 208/230V 14.7 (44.1) 91 (273) 2.4 (9.6) 4.7 (18.8) 2 3 5 2.2 3.7 1.5 7.5 10.6 16.7 46.9 66 105 80 80 90 80 90 70 70 73 79 65 68 75 (2) 1/3 (249) 4.8 9.4 15 LGC156H2B (R−22) 460V 7.1 (21.3) 50 (150) 1.3 (5.2) 2.4 (9.6) 2 3 5 1.5 2.2 3.7 3.4 4.8 7.6 20.4 26.8 45.6 40 40 45 35 40 40 35 36 39 32 34 36 (2) 1/3 (249) 2.6 4.8 15 575V 5.1 (15.3) 37 (111) 1 (4) 1.9 (7.6) 2 3 5 1.5 2.2 3.7 2.7 3.9 6.1 16.2 23.4 36.6 30 30 35 25 25 30 26 27 29 24 25 27 (2) 1/3 (249) 2 3.8 15 208/230V 15.4 (46.2) 124 (372) 2.4 (9.6) 4.7 (18.8) 3 5 7.5 3.7 5.6 2.2 10.6 16.7 24.2 66 105 152 90 90 110 90 110 80 76 82 89 77 84 71 (2) 1/3 (249) 4.8 9.4 15 LGC180S2B (R−22) 460V 7.4 (22.2) 59.6 (178.8) 1.3 (5.2) 2.4 (9.6) 3 5 7.5 2.2 3.7 5.6 4.8 7.6 11 26.8 45.6 66 40 45 50 40 40 50 37 40 43 35 37 41 (2) 1/3 (249) 2.6 4.8 15 575V 5.9 (17.7) 49.4 (148.2) 1 (4) 1.9 (7.6) 3 5 2.2 3.7 3.9 6.1 23.4 36.6 35 35 30 35 30 32 28 30 (2) 1/3 (249) 2 3.8 15 15 TON STANDARD EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((3)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t (4) FanMotors Lockedrotoramps each(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti ((amps)) Protection No PEF 2 Minimum Circuit With Standard PEF A Ampacity it No PEF (Number)Horsepower (W) Optional p Standard St ti Power Static P Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) 7.5 5.6 9 54 40 40 35 33 15 TON HIGH EFFICIENCY ModelNo. LGC180H2B (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V Rated load amps each (total) 17.3 (51.9) 9 (27) 7.1 (21.3) Compressors p ((3)) Locked rotor amps each (total) 123 (369) 62 (186) 50 (150) Fullloadamps each(total) 2.4 (9.6) 1.3 (5.2) 1 (4) Condenser F M t FanMotors (4) 2.4 (9.6) 1.9 (7.6) Lockedrotoramps each(total) 4.7 (18.8) Motor Output − hp 3 5 7.5 3 5 7.5 3 5 7.5 Evaporator p Bl M t Blower Motor kW 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 Fullloadamps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Lockedrotoramps 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Maximum Overcurrent With Standard PEF 90 100 110 50 50 50 40 40 45 P t ti ((amps)) Protection No PEF 90 90 110 45 50 50 35 40 45 2 Minimum Circuit With Standard PEF 82 88 95 42 45 49 33 36 39 A it Ampacity No PEF 77 83 91 40 43 46 31 34 37 (Number)Horsepower (W) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) Optional p Standard St ti Power Static P Fullloadamps(total) 4.8 2.6 2 Exhaust Fans Lockedrotoramps(total) 9.4 4.8 3.8 Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15 LGC180H4B (R−410A) 208/230V 460V 575V 20.5 (61.5) 9.6 (28.8) 7.6 (22.8) 155 (465) 75 (225) 54 (162) 2.4 (9.6) 1.3 (5.2) 1 (4) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) 3 5 7.5 3 5 7.5 3 5 7.5 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 66 105 152 26.8 45.6 66 23.4 36.6 54 110 110 125 50 50 60 40 40 45 110 110 125 50 50 50 40 40 45 92 98 106 44 47 50 35 37 40 87 93 101 42 44 48 33 35 38 (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) 4.8 2.6 2 9.4 4.8 3.8 15 15 15 NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 47 ELECTRICAL DATA 17.5 TON STANDARD / HIGH EFFICIENCY ModelNo. LGC210S2B (R−22) LGC210H2B (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V 208/230V 460V 575V Rated load amps each (total) 14.7 (58.8) 7.1 (28.4) 5.8 (23.2) 14.7 (58.8) 7.1 (28.4) 5.1 (20.4) Compressors p ((4)) Locked rotor amps each (total) 91 (364) 50 (200) 37 (148) 91 (364) 50 (200) 37 (148) Fullloadamps each (total) 2.4 (9.6) 1.3 (5.2) 1 (4) 2.4 (9.6) 1.3 (5.2) 1 (4) Condenser F M t (4) FanMotors 2.4 (9.6) 1.9 (7.6) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) Lockedrotoramps each (total) 4.7 (18.8) Motor Output − hp 3 5 7.5 3 5 7.5 3 5 7.5 3 5 7.5 3 5 7.5 3 5 7.5 Evaporator p Bl Blower M Motor t kW 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 2.2 3.7 5.6 Fullloadamps 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 10.6 16.7 24.2 4.8 7.6 11 3.9 6.1 9 Lockedrotoramps 66 105 152 26.8 45.6 66 23.4 36.6 54 66 105 152 26.8 45.6 66 23.4 36.6 54 1 Maximum Overcurrent With Standard PEF 100 110 125 45 50 60 40 40 45 100 110 125 45 50 60 35 40 45 P t ti (amps) ( ) Protection No PEF 90 100 110 45 50 50 35 40 45 90 100 110 45 50 50 30 35 40 2 Minimum Circuit With Standard PEF 88 94 102 43 46 49 35 37 40 88 94 102 43 46 49 32 34 37 A Ampacity it No PEF 83 89 97 41 43 47 33 35 38 83 89 97 41 43 47 30 32 35 (No.)Horsepower (W) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) Optional p Standard St ti Power Static P Fullloadamps(total) 4.8 2.6 2 4.8 2.6 2 Exhaust Fans Lockedrotoramps(total) 9.4 4.8 3.8 9.4 4.8 3.8 Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15 15 15 15 20 TON STANDARD EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps(total) Condenser F M t (4) FanMotors Lockedrotoramps(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti (amps) ( ) Protection No PEF 2 Minimum Circuit With Standard PEF A Ampacity it No PEF (No.)Horsepower (W) Optional p Standard St ti Power Static P Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) 208/230V 15.4 (61.6) 124 (469) 2.4 (9.6) 4.7 (18.8) 5 7.5 10 5.6 7.5 3.7 16.7 24.2 30.8 105 152 193 110 125 125 125 125 100 97 105 111 100 106 92 (2) 1/3 (249) 4.8 9.4 15 LGC240S2B (R−22) 460V 7.4 (29.6) 59.6 (238.4) 1.3 (5.2) 2.4 (9.6) 5 7.5 10 3.7 5.6 7.5 7.6 11 14 45.6 66 84 50 60 60 50 50 60 47 51 54 45 48 51 (2) 1/3 (249) 2.6 4.8 15 575V 5.9 (23.6) 49.4 (197.6) 1 (4) 1.9 (7.6) 5 7.5 3.7 5.6 6.1 9 36.6 54 40 45 40 45 38 41 36 39 (2) 1/3 (249) 2 3.8 15 10 7.5 11 66 50 50 43 41 20 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps(total) Condenser F M t (4) FanMotors Lockedrotoramps(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti (amps) ( ) Protection No PEF 2 Minimum Circuit With Standard PEF A Ampacity it No PEF (No.)Horsepower (W) Optional p Standard St ti Power Static P Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) LGA240H2B (R−22) 208/230V 460V 575V 17.3 (69.2) 9 (36) 7.1 (28.4) 123 (492) 62 (248) 50 (200) 2.4 (9.6) 1.3 (5.2) 1 (4) 2.4 (9.6) 1.9 (7.6) 4.7 (18.8) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 110 125 150 60 60 70 45 50 50 110 125 125 60 60 70 45 50 50 105 113 119 54 58 61 43 46 48 100 108 114 52 55 58 41 44 46 (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) 4.8 2.6 2 9.4 4.8 3.8 15 15 15 NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 48 LGA240H4B (R−410A) 208/230V 460V 575V 20.5 (82) 9.6 (38.4) 7.6 (30.4) 155 (620) 75 (300) 54 (216) 2.4 (9.6) 1.3 (5.2) 1 (4) 4.7 (18.8) 2.4 (9.6) 1.9 (7.6) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 150 150 60 70 70 50 50 60 125 125 150 60 60 70 50 50 50 119 126 133 57 60 63 45 48 50 114 121 128 54 57 60 43 46 48 (2) 1/3 (249) (2) 1/3 (249) (2) 1/3 (249) 4.8 2.6 2 9.4 4.8 3.8 15 15 15 ELECTRICAL DATA 21 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps(total) Condenser F M t FanMotors (6) Lockedrotoramps(total) Motor Output − hp Evaporator p Bl M t Blower Motor kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti (amps) ( ) Protection With 50% High Static PEF With 100% High Static PEF No PEF 2 Minimum Circuit With Standard PEF A Ampacity it With 50% High Static PEF With 100% High Static PEF No PEF (No.)Horsepower (W) Optional p St d d St Standard Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) (No.)Horsepower (W) Optional p 50% Hi High h St Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) (No.)Horsepower (W) Optional p 100% Hi High h St Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) LGA248H2B (R−22) 208/230V 460V 575V 17.3 (69.2) 9 (36) 7.1 (28.4) 123 (492) 62 (248) 50 (200) 2.4 (14.4) 1.3 (7.8) 1 (6) 2.4 (14.4) 1.9 (11.4) 4.7 (28.2) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 125 150 60 70 70 50 50 60 125 150 150 70 70 80 50 60 60 150 150 175 70 70 80 60 60 60 110 125 150 60 60 70 45 50 50 112 120 126 58 61 64 46 49 51 120 128 134 61 64 67 48 51 53 128 135 142 64 68 71 51 54 56 105 113 119 54 58 61 43 46 48 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 (2) 2 (1491) (2) 2 (1491) (2) 2 (1491) 7.5 (15) 3.4 (6.8) 2.7 (5.4) 69.4 (138.8) 31.4 (62.8) 20.1 (40.2) (3) 2 (1491) (3) 2 (1491) (3) 2 (1491) 7.5 (22.5) 3.4 (10.2) 2.7 (8.1) 69.4 (208.2) 31.4 (94.2) 20.1 (60.3) 15 15 15 LGA248H4B (R−410A) 208/230V 460V 575V 18.1 (72.4) 9 (36) 6.8 (27.2) 137 (548) 62 (248) 50 (200) 2.4 (14.4) 1.3 (7.8) 1 (6) 4.7 (28.2) 2.4 (14.4) 1.9 (11.4) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 125 125 150 60 70 70 50 50 60 125 150 150 70 70 80 50 50 60 150 150 175 70 70 80 50 60 60 125 125 150 60 60 70 45 50 50 116 123 130 58 61 64 44 47 49 124 131 138 61 64 67 47 50 52 131 139 145 64 68 71 50 52 54 109 116 123 54 58 61 41 44 46 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 (2) 2 (1491) (2) 2 (1491) (2) 2 (1491) 7.5 (15) 3.4 (6.8) 2.7 (5.4) 69.4 (138.8) 31.4 (62.8) 20.1 (40.2) (3) 2 (1491) (3) 2 (1491) (3) 2 (1491) 7.5 (22.5) 3.4 (10.2) 2.7 (8.1) 69.4 (208.2) 31.4 (94.2) 20.1 (60.3) 15 15 15 25 TON STANDARD EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t FanMotors (4) Lockedrotoramps each(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti (amps) Protection ( ) No PEF 2 Minimum Circuit With Standard PEF A Ampacity it No PEF (No.)Horsepower (W) Optional Standard p St ti Power P Static Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) 208/230V 18.6 (74.4) 156 (624) 3 (12) 6 (24) 5 7.5 10 5.6 7.5 3.7 16.7 24.2 30.8 105 152 193 125 125 150 125 150 125 113 121 127 116 122 108 (2) 1/3 (249) 4.8 9.4 15 LGC300S2B (R−22) 460V 9 (36) 75 (300) 1.5 (6) 3 (12) 5 7.5 10 3.7 5.6 7.5 7.6 11 14 45.6 66 84 60 60 70 60 60 70 55 58 61 52 56 59 (2) 1/3 (249) 2.6 4.8 15 575V 7.4 (29.6) 54 (216) 1.2 (4.8) 2.9 (11.6) 5 7.5 3.7 5.6 6.1 9 36.6 54 50 50 45 50 45 48 43 46 (2) 1/3 (249) 2 3.8 15 10 7.5 11 66 60 50 50 48 NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 49 ELECTRICAL DATA 25 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t (6) FanMotors Lockedrotoramps each(total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti (amps) ( ) Protection With 50% High Static PEF With 100% High Static PEF No PEF 2 Minimum Circuit With Standard PEF A Ampacity it With 50% High Static PEF With 100% High Static PEF No PEF (No.)Horsepower (W) Optional p Standard St ti Power Static P Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) (No.)Horsepower (W) Optional p 50% Hi High h St Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) (No.)Horsepower (W) Optional p 100% Hi High h St Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) 208/230V 18.6 (74.4) 156 (624) 2.4 (14.4) 4.7 (28.2) 5 7.5 10 5.6 7.5 3.7 16.7 24.2 30.8 105 152 193 125 150 150 150 150 150 150 150 175 125 125 150 118 125 132 133 140 126 133 141 147 111 118 125 (3) 1/3 (249) 7.2 14.1 (2) 2 (1491) 7.5 (15) 69.4 (138.8) (3) 2 (1491) 7.5 (22.5) 69.4 (208.2) 15 LGC300H2B / LGC300H2V (R−22) 460V 9 (36) 75 (300) 1.3 (7.8) 2.4 (14.4) 5 7.5 10 3.7 5.6 7.5 7.6 11 14 45.6 66 84 60 70 70 70 70 80 70 70 80 60 60 70 58 61 64 61 64 67 64 68 71 54 58 61 (3) 1/3 (249) 3.9 7.2 (2) 2 (1491) 3.4 (6.8) 31.4 (62.8) (3) 2 (1491) 3.4 (10.2) 31.4 (94.2) 15 575V 7.4 (29.6) 54 (216) 1 (6) 1.9 (11.4) 5 7.5 3.7 5.6 6.1 9 36.6 54 50 50 50 60 60 60 50 50 47 50 49 52 52 55 44 47 (3) 1/3 (249) 3 5.7 (2) 2 (1491) 2.7 (5.4) 20.1 (40.2) (3) 2 (1491) 2.7 (8.1) 20.1 (60.3) 15 10 7.5 11 66 60 60 60 60 52 54 57 49 30 TON HIGH EFFICIENCY ModelNo. LGA360H2B (R−22) Linevoltagedata−60Hz−3phase 208/230V 460V 575V Rated load amps each (total) 30.1 (90.3) 15.5 (46.5) 12.1 (36.3) Compressors p ((3)) Locked rotor amps each (total) 225 (675) 114 (342) 80 (240) Fullloadamps each(total) 2.4 (14.4) 1.3 (7.8) 1 (6) Condenser F M t FanMotors (6) 2.4 (14.4) 1.9 (11.4) Lockedrotoramps each (total) 4.7 (28.2) Motor Output − hp 5 7.5 10 5 7.5 10 5 7.5 10 Evaporator p Bl M t Blower Motor kW 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 Fullloadamps 16.7 24.2 30.8 7.6 11 14 6.1 9 11 Lockedrotoramps 105 152 193 45.6 66 84 36.6 54 66 1 Maximum Overcurrent With Standard PEF 150 150 175 80 80 90 60 60 70 P t ti (amps) ( ) Protection With 50% High Static PEF 150 175 175 80 90 90 60 70 70 With 100% High Static PEF 175 175 175 90 90 90 70 70 70 No PEF 150 150 150 80 80 80 60 60 60 2 Minimum With Standard PEF 137 144 151 70 74 77 55 58 60 Ci Circuit it A Ampacity it With 50% High Static PEF 144 152 159 73 76 79 57 60 62 With 100% High Static PEF 152 159 166 76 80 83 60 63 65 No PEF 129 137 144 66 70 73 52 55 57 (No.)Horsepower (W) (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) Optional p Standard St ti Power Static P Fullloadamps(total) 7.2 3.9 3 Exhaust Fans Lockedrotoramps(total) 14.1 7.2 5.7 (No.)Horsepower (W) (2) 2 (1491) (2) 2 (1491) (2) 2 (1491) Optional p 50% Hi High h St Static ti Fullloadamps(total) 7.5 (15) 3.4 (6.8) 2.7 (5.4) Power Exhaust Fans Lockedrotoramps(total) 69.4 (138.8) 31.4 (62.8) 20.1 (40.2) (No.)Horsepower (W) (3) 2 (1491) (3) 2 (1491) (3) 2 (1491) Optional p 100% Hi High h St Static ti Fullloadamps(total) 7.5 (22.5) 3.4 (10.2) 2.7 (8.1) Power Exhaust Fans Lockedrotoramps(total) 69.4 (208.2) 31.4 (94.2) 20.1 (60.3) Service Outlet (2) 115 volt GFCI (amp rating) 15 15 15 NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 50 LGA360H4B (R−410A) 208/230V 460V 575V 33.3 (99.9) 17.9 (53.7) 11.5 (34.5) 239 (717) 125 (375) 80 (240) 2.4 (14.4) 1.3 (7.8) 1 (6) 4.7 (28.2) 2.4 (14.4) 1.9 (11.4) 5 7.5 10 5 7.5 10 5 7.5 10 3.7 5.6 7.5 3.7 5.6 7.5 3.7 5.6 7.5 16.7 24.2 30.8 7.6 11 14 6.1 9 11 105 152 193 45.6 66 84 36.6 54 66 175 175 175 90 90 100 60 60 60 175 175 200 90 100 100 60 60 70 175 200 200 100 100 100 60 70 70 150 175 175 90 90 90 60 60 60 147 155 161 78 81 84 53 56 58 155 162 169 81 84 87 55 58 60 162 170 176 84 88 91 58 61 63 140 147 154 74 77 80 50 53 55 (3) 1/3 (249) (3) 1/3 (249) (3) 1/3 (249) 7.2 3.9 3 14.1 7.2 5.7 (2) 2 (1491) (2) 2 (1491) (2) 2 (1491) 7.5 (15) 3.4 (6.8) 2.7 (5.4) 69.4 (138.8) 31.4 (62.8) 20.1 (40.2) (3) 2 (1491) (3) 2 (1491) (3) 2 (1491) 7.5 (22.5) 3.4 (10.2) 2.7 (8.1) 69.4 (208.2) 31.4 (94.2) 20.1 (60.3) 15 15 15 ELECTRICAL DATA 30 TON HIGH EFFICIENCY ModelNo. Linevoltagedata−60Hz−3phase Rated load amps each (total) Compressors p ((4)) Locked rotor amps each (total) Fullloadamps each(total) Condenser F M t (6) FanMotors Lockedrotoramps each (total) Motor Output − hp Evaporator p Bl Blower M Motor t kW Fullloadamps Lockedrotoramps 1 Maximum Overcurrent With Standard PEF P t ti (amps) ( ) Protection With 50% High Static PEF With 100% High Static PEF No PEF 2 Minimum With Standard PEF Ci Circuit it A Ampacity it With 50% High Static PEF With 100% High Static PEF No PEF (No.)Horsepower (W) Optional p Standard St ti Power Static P Fullloadamps(total) Exhaust Fans Lockedrotoramps(total) (No.)Horsepower (W) Optional p 50% Hi High h St Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) (No.)Horsepower (W) Optional p 100% Hi High h St Static ti Fullloadamps(total) Power Exhaust Fans Lockedrotoramps(total) Service Outlet (2) 115 volt GFCI (amp rating) 208/230V 22.4 (89.6) 164 (656) 2.4 (14.4) 4.7 (28.2) 5 7.5 10 5.6 7.5 3.7 16.7 24.2 30.8 105 152 193 150 150 175 150 175 150 150 175 175 150 150 150 134 141 148 149 156 142 149 157 163 127 134 141 (3) 1/3 (249) 7.2 14.1 (2) 2 (1491) 7.5 (15) 69.4 (138.8) (3) 2 (1491) 7.5 (22.5) 69.4 (208.2) 15 LGC360H2V (R−22) 460V 10.9 (43.6) 100 (400) 1.3 (7.8) 2.4 (14.4) 5 7.5 10 3.7 5.6 7.5 7.6 11 14 45.6 66 84 70 80 80 70 80 80 80 80 90 70 70 80 66 70 73 69 72 75 72 76 79 62 66 69 (3) 1/3 (249) 3.9 7.2 (2) 2 (1491) 3.4 (6.8) 31.4 (62.8) (3) 2 (1491) 3.4 (10.2) 31.4 (94.2) 15 575V 8.3 (33.2) 78 (312) 1 (6) 1.9 (11.4) 5 7.5 3.7 5.6 6.1 9 36.6 54 60 60 60 60 60 60 50 60 51 54 53 56 56 59 48 51 (3) 1/3 (249) 3 5.7 (2) 2 (1491) 2.7 (5.4) 20.1 (40.2) (3) 2 (1491) 2.7 (8.1) 20.1 (60.3) 15 10 7.5 11 66 60 60 70 60 56 58 61 53 NOTE− Extremesofoperatingrangeareplusandminus10%oflinevoltage. 1 HACR type breaker or fuse. 2 RefertoNational or CanadianElectricalCodemanualtodeterminewire,fuseanddisconnectsizerequirements. OUTDOOR SOUND DATA Octave Band Sound Power Levels dBa, re 10−12 Watts *Unit Model No. 1 Center Frequency − HZ 1 Sound Rating Number (dB) 125 250 500 1000 2000 4000 8000 156H, 180S, 180H 97 92 91 88 83 79 72 93 210S, 210H, 240S, 240H 94 91 90 87 83 79 72 92 300S 96 93 90 87 82 76 65 93 248H, 300H 95 93 92 88 84 81 75 94 360H 94 93 93 90 86 81 75 95 Tested according to ARI Standard 270-95 test conditions and ANSI Standard S1.32-1981. INSTALLATION CLEARANCES − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) OUTDOOR AIR HOOD *NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal 36 (914) *41 (1041) NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface. NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal 36 (914) 36 (914) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 51 INSTALLATION CLEARANCES − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) − Unit With Economizer OUTDOOR AIR HOOD *NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal 36 (914) *41 (1041) 36 (914) NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface. 36 (914) NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal 21, 25, and 30 TON (248H, 300H, and 360H) − Unit With High Static Power Exhaust Fans 80 (2032) OUTDOOR AIR HOOD *NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal *41 (1041) 36 (914) NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface. 36 (914) NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal 21, 25, and 30 TON (248H, 300H, and 360H) − Unit With Horizontal Barometric Relief Dampers OPTIONAL BAROMETRIC RELIEF EXHAUST DAMPERS (Field Installed on Return Air Duct) NOTE Allow adequate clearance for duct and barometric relief damper installation. NOTE Dampers may be installed on each side of return air duct or end to end on one side of return air duct. OUTDOOR AIR HOOD *NOTE − 66 in. (1676 mm) Recommended service clearance for blower deck removal NOTE − Top Clearance 60 in. (1524 mm). NOTE − Entire perimeter of unit base requires support when elevated above mounting surface. NOTE − 60 in. (1524 mm) Recommended service clearance for heat exchanger removal L Series Packaged Gas/Electric − 13 to 30 Tons / Page 52 *41 (1041) 36 (914) 36 (914) L CONNECTION® BUILDING AUTOMATION SYSTEM Network Control Up To 31 Units − Integrates with Integrated Modular Control (IMC) Control on S−Classt and L Series® Packaged Units and other non−IMC Lennox or Aftermarket Equipment with optional DDC Network Thermostat Controller (NTC) − 7 Day Programming plus Holidays − Six Different Time/Temperature Schedules per Day − Storage of Last 75 Alarms With Time/Date − Remote Access (with PC Software) − Large LCD Display Screen NCP1 Network Control Panel 59L21 ZONE TEMPERATURE SENSORS (One sensor required per unit) Order No. Description Wall−Mount After Hours Override Button − Terminal Block Connection − Network Jack for L Connection PC Software Wall Mounted Zone Sensor − With warmer/cooler adjustment 56L80 Wall Mounted Zone Sensor − Without warmer/cooler adjustment 94L60 Miniature Wall−Mount − Terminal Block Connection Miniature Wall Mounted Zone Sensor 94L61 Wall−Mount − Terminal Block Connection Wall Mounted Zone Sensor − use with Building Controller (BC1) for monitoring critical areas 59M04 Wall−Mount − Wire Lead Connection Flush Mount Zone Sensor 76M32 Temperature Averaging Kit Two zone sensors for temperature averaging in one room 23M20 Duct−Mount (For return air duct) Duct Mounted Zone Sensor 56L81 Wall Mounted Zone Humidity Sensor 17M50 Duct Mounted Relative Humidity Sensor 76M31 ZONE HUMIDITY SENSOR OUTDOOR TEMPERATURE SENSOR Mounted in watertight enclosure with a sun shield. Use with Building Controller (BC1) to monitor outdoor temperature 59M05 CO2 SENSORS CO2 − Wall mount, white case, digital display CO2 − Wall mount, white case, no display CO2 − Wall mount, black case, digital display CO2 − Wall mount, black case, no display (UL rated for interior duct and plenum mounting) AFTER HOURS REMOTE OVERRIDE BUTTON After Hours Remote Override Button − Wall Plate furnished (Use with Duct Mounted Zone Sensor if required) 77N39 87N53 87N52 87N54 56L16 L Series Packaged Gas/Electric − 13 to 30 Tons / Page 53 L CONNECTION® BUILDING AUTOMATION SYSTEM Description Order No. NETWORK THERMOSTAT CONTROL − DDC that allows network control of all other non−IMC Lennox or aftermarket equipment over L Connectiont Network 1 Description Order No. NTC1 − 2 Htg.−3 Clg. 17M10 PC SOFTWARE FOR SETUP, CONFIGURATION AND SCHEDULE ADJUSTMENT OF THE NETWORK CONTROL PANEL (NCP) Network Control Panel (NCP) Software For Remote/Local NCP access 96L82 NOTE − Version 2.06 or higher is required for use with M1−7 IMC Controller Requires PC Converter Kit (96L78) for local access and Network Modem Kit (94L62) for remote access FOR SETUP, CONFIGURATION AND SERVICING OF INTEGRATED MODULAR CONTROL (IMC), BUILDING CONTROLLER AND NETWORK THERMOSTAT CONTROL (NTC) Unit Controller Software For Remote/Local network control 96L80 NOTE − Version 2.06 or higher is required for use with M1−7 IMC Controller Requires PC Converter Kit (96L78) for local access and Network Modem Kit (94L62) for remote access LENNOX COMMERCIAL CONTROLS SELECTION SOFTWARE Includes L Connection® (and Sectra®) Estimator Software for product selection and submittal information 34M78 NETWORK MODEM KIT − Provides direct digital communication between a single rooftop unit (or network of rooftop units) and the Network Control Panel Connects phone line directly to L Connection network − Includes modem, PC Converter, cables 94L62 NOTE − Requires either NCP software and/or Unit Controller Software BUILDING CONTROLLER BC1−1 − Use to control lights, vent hoods, exhaust fans, sprinklers and other devices based upon unit occupied operation or time schedule. 17M12 NETWORK ETHERNET CONVERTER − Required to interface between the L Connection network and an Ethernet LAN (local area network). Includes Ethernet converter, L Connection modem converter, cable, and transformer 76M77 NOTE − Requires L Connection Unit Controller and/or NCP software (version 2.05 or higher) Does NOT require Network Bus to PC Converter Kit (96L78) 1 Computer system requirements: IBM compatible PC with Pentium or higher processor, Microsoft® Windows® 95, 98, Me, 2000, XP, or NT®. (Windows® 95, Windows® 98, Windows® Me, Windows® 2000, Windows® XP, and Windows® NT® are registered trademarks of Microsoft Corp.), 256 MB RAM (more memory may be required to run additional applications simultaneously), requires at least 20 MB of free hard drive space, VGA or higher resolution monitor (screen resolution must be 800 X 600 or higher and 256 colors), CD−ROM drive, mouse or compatible pointing device, serial COM port, PC modem (US Robotics® model no. USR5699B, USR5610B, USR5686E, 005686−03, 3CP5610A, 3CP5699A, 005687−03, or USR3686D is recommended) for remote connections. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 54 L CONNECTION® BUILDING AUTOMATION SYSTEM Description Order No. Used with the Building Controller, the monitor sends a 24VAC output to a building control device to load shed when electrical demand is high. 76M33 kWH DEMAND CONTROLLER NOTE − Requires kWH meter with KYZ output. AMBIENT LIGHT SENSOR Use with the Building Controller and Network Control Panel for automatic lighting control 34M67 NEMA 1 ENCLOSURES NEMA Enclosure 17M11 For Network Modem Kit or Building Controller 34M23 For Network Control Panel 34M24 NETWORK PHONE LINE AUTO−ROUTER (Allows modem, fax and phone to share one line − routes signal to connect to device automatically) Network Phone Line Auto−Router 34M22 NETWORK BUS TO PC CONVERTER KIT Allows PC connection directly to L Connection® network − Required for any L Connection® PC software when used on a local network 96L78 NOTE − Not required for use with Ethernet Converter Kit (76M77) COMMUNICATION CABLE 500 ft. Roll − RS−485 twisted pair communication wire − plenum rated 27M19 1 76M76 500 ft. Roll − RS−485 double twisted pair communication wire − plenum rated 1000 ft. Roll − RS−485 twisted pair communication wire − plenum rated 94L63 2500 ft. Roll − RS−485 twisted pair communication wire − plenum rated 68M25 1 Three wires are required for CO2 Sensors or Humidity Sensors. NETWORK CONTROL PANEL WALL TRANSFORMER − Separate power supply for NCP (if desired) Screw terminals Transformer − 20VA, Class 2, Primary 120V, 60Hz, Secondary 24V 18M13 FACTORY INSTALLED COMPONENTS Air Flow Switch Dirty Filter Switch Factory Installed L Series Packaged Gas/Electric − 13 to 30 Tons / Page 55 SECTRAt COMMERCIAL ZONING SYSTEM − FACTORY INSTALLED SECTRA SINGLE ZONE CONTROL Module monitors and controls heating, cooling and economizer functions of Lennox’ S−Classt and L Series® rooftop equipment configured for single−zone applications. Up to 50 zoned (bypass or VFD) and single zone (DDC or communicating thermostat) units can be combined on a single Sectra Commercial Zoning System network (maximum of 120 LonWorks® nodes). Allows 2 stage heat/3 stage cool demands to operate 1 four stages of cooling and heating by grouping compressors/heat stages in the factory IMC configuration. Uses LonTalk protocol, conforming with LonMark® Rooftop Unit Functional Profile. Occupied, unoccupied, standby, override, start−up and wait, cooling, heating, emergency heat, off, disabled, freeze protect, manual position, and fan−only modes. Factory installed complete with return air temperature sensor and blower proving switch. Controls economizer damper via minimum position, proportional free cooling (sensible, single enthalpy, or differential enthalpy), or demand control ventilation using an optional carbon dioxide sensor. Supports modulating hydronic valves for heating and/or cooling. A total of one resistive analog input, two binary inputs, and six relay outputs are available. 1 Sectra Single Zone Control is not compatible with the Four Stage Control Board (FS1). SECTRA BYPASS CONTROL Module monitors and controls heating, cooling and economizer functions of Lennox’ S−Classt and L Series® rooftop equipment configured for pressure dependent constant volume bypass applications. Controls up to 18 zones per rooftop unit, with up to 50 combined zoned (bypass or VFD) and single zone (DDC or communicating thermostat) units on a single Sectra Commercial Zoning System network (maximum of 120 LonWorks nodes). Allows 2 stage heat/3 stage cool demands to operate 1 four stages of cooling and heating by grouping compressors/heat stages in the factory IMC configuration. Modulates bypass damper to maintain constant static pressure input as zone dampers modulate. Occupied, unoccupied, vent and shutdown modes. Factory installed complete with return air temperature sensor, discharge air temperature sensor, and blower proving switch. Controls economizer damper via minimum position, proportional free cooling ( sensible, single enthalpy, or differential enthalpy), or demand control ventilation using an optional carbon dioxide sensor. Supports modulating hydronic valves for heating and/or cooling. A total of eight analog inputs, eight binary inputs, eight binary outputs, and six analog outputs are available. 1 Sectra Bypass Control is not compatible with the Four Stage Control Board (FS1). SECTRA VFD CONTROL Module works with the Integrated Modular Controller (IMC) control module to monitor and control heating and cooling functions of Lennox’ S−Classt and L Series® rooftop equipment configured for pressure dependent, variable air volume applications with a factory mounted variable frequency drive (VFD). Controls up to 18 zones per rooftop unit, with up to 50 combined zoned (bypass or VFD) and single zone (DDC or communicating thermostat) units on a single Sectra Commercial Zoning System network (maximum of 120 LonWorks nodes). Module communicates with IMC using blower enable (G), occupied (OCP), discharge cooling enable (Y1), and discharge heating enable (W1) digital outputs. IMC modulates VFD to maintain constant static pressure input as zone dampers modulate. IMC controls 4 stage heat/4 stage cool 1 individually based on discharge air temperature input. Economizer, demand control ventilation, power exhaust, and other unit functionality are controlled directly by the IMC. 1 Sectra Bypass Control is not compatible with the Four Stage Control Board (FS1). AFTERMARKET ZONING SYSTEMS See "Aftermarket Zoning System Interface" in the Controls Application Guide section of this document. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 56 SECTRAt COMMERCIAL ZONING SYSTEM − FIELD INSTALLED SECTRA ROOFTOP UNIT CONTROL KITS Single Zone Control − Includes controller, blower proving switch, return air temperature sensors, mounting bracket, and wiring harness Sectra Single Zone Control − L Series® 7.5 to 30 ton (CAV Models) Sectra Single Zone Control − L Series® 71M59 3 to 6 ton, S−Classt 40 ton (CAV Models) 21M51 Bypass Control − Includes controller, blower proving switch, return and discharge air temperature sensors, mounting bracket, and wiring harness Sectra Bypass Control − L Series® 7.5 to 30 ton Sectra Bypass Control − L Series® 34M42 3 to 6 ton, S−Classt 40 ton 34M41 Sectra VFD Control −− Includes controller and wiring harness to communicate with IMC controller Sectra VFD Control − L Series® 25−30 ton (300H − 360H) (VFD Models) 83M59 Sectra VFD Control − S−Classt 40 ton (VFD Models) 83M58 NOTE − All Rooftop Unit Control Kits require 75VA transformer (32M78) SECTRA ROOFTOP UNIT CONTROL SENSORS Temperature −− Wall mount, three hour override button, override status LED, and setpoint adjust 29M56 Temperature −− Wall mount, without override or setpoint adjust 29M55 Temperature −− Wallplate, without override or setpoint adjust 85X52 Temperature − Duct mount, discharge air 19L22 CO2 − Wall mount white case, no display 87N53 CO2 − Wall mount, black case, no display (UL rated for interior duct and plenum mounting) 87N54 CO2 − Wall mount, white case, digital display 77N39 CO2 − Duct Kit − Aspiration box to mount any CO2 sensor in duct 90N43 Switch − Dirty Filter 30K48 Relay − Baseboard auxiliary heat 56L68 SECTRA PROGRAMMABLE THERMOSTAT Three stage heating/cooling, seven day programmable, four periods/day, intelligent recovery, automatic or manual changeover 60L59 Communicating subbase, conforms to LonMark® Thermostat Functional Profile (required for use with Sectra network) 82N52 SECTRA THERMOSTAT SENSORS Remote wall mount temperature sensor with setpoint adjust 58C92 1 86G67 Remote wall mount temperature sensor with three hour override button, override status LED, and setpoint adjust Remote duct mount return air temperature sensor 27C40 2 66P91 Remote wall mount averaging temperature sensor 1, 2 Remote wall mount averaging temperature sensor 16P03 1 In averaging sensor applications, one 86G67 sensor can replace one 16P03 sensor (only one 86G67 can be used per thermostat). 2 Remote averaging sensors can be used in the following combinations only: (1) 16P03, (2) 66P91’s, (2) 16P03’s and (1) 66P91, (4) 16P03’s, (5) 66P91’s or (9) 16P03’s. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 57 SECTRAt COMMERCIAL ZONING SYSTEM − FIELD INSTALLED SECTRA ROOFTOP UNIT CONTROL SCHEDULER Scheduler − Maintains schedules for up to four rooftop unit controllers 29M49 NOTE − 75VA transformer (32M78) required SECTRA ROOFTOP UNIT CONTROL NETWORK DISPLAY Network Display − Local interface to monitor and control Sectra network setpoints, schedules and alarms 29M50 NOTE − 75VA transformer (32M78) required SECTRA NETWORK MODEM Modem − allows remote telephone communications to network, includes transformer 32M03 Modem cable −− DB9 to DB25 serial cable to connect modem to SLTA 54X01 NOTE: SLTA (92N65) required to connect modem to Sectra network SECTRA SERIAL LONTALK® ADAPTOR STLA − Provides communication between Sectra network and PC or modem 92N65 Operations Kit − Cable to connect SLTA to PC, 120/24VAC transformer for SLTA with power cord, instructions 83X18 NOTE: Modem (32M03) and modem cable (54X01) required for remote communication SECTRA SOFTWARE Lennox Commercial Controls Selection Software − Includes Sectra® (and L Connection®) Estimator Software for product selection and submittal information 34M78 Sectrat Configurator − Windows® based PC software to configure, monitor and control Sectra system 29M57 SECTRA ZONE CONTROLLER Zone Controller − Combined controller/actuator modulates zone damper based on signal from zone sensor, reports demand to rooftop unit controller 29M52 NOTE − 75VA transformer (32M78) required − Compatible with Sectra Bypass and Sectra VFD applications SECTRA BYPASS DAMPER ACTUATOR Bypass Damper Actuator − Modulates bypass damper based on signal from rooftop unit controller 29M16 NOTE − 75VA transformer (32M78) required Static Pressure Transducer − Sends pressure signal to Sectra rooftop unit controller for bypass control 78M19 SECTRA TRANSFORMER Transformer − 75VA, 120/208/220V primary, 24V secondary at rated power output 32M78 NOTE − Transformer can be used with unit controllers, Sectra Network Display, etc. SECTRA LONWORKS® NETWORK WIRING LonWorks Wire − 1000 feet, 22AWG, unshielded twisted pair, plenum rated, daisy chain on free topology transceiver (FTT) network 84X49 Four Way Repeater − Required for Sectra networks exceeding 4600 ft. (1400 m) in length or a combined 60 LonWorks nodes 99X43 Termination Module − Required at each non−repeater termination point (typically two per Sectra network) 37X75 NOTE − If repeater is present, one termination module is required per subnet − maximum four subnets. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 58 OPTIONAL UNIT CONTROLLERS − FACTORY OR Field Installed Field Installed Catalog No. System and Component Description CPC 810−3062 Control Module/Blower Proving Switch/Return Air Sensor/Discharge Air Sensor/Wiring Harness − Network communications (RS−485, shielded pair twisted wire), 8 analog/digital inputs, 8 form−C relay outputs, 2 analog outputs, 24 VAC, output connections (2 stage heat/2 stage cool, 2 auxiliary outputs (user defined), economizer, fan), input connections (space temperature, discharge and return air temperature, 2 compressor monitoring, 2 aux. inputs (user defined), local override (1 to 240 minutes), Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Return Air Sensor provides input to module to determine heating or cooling operation and number of stages required, Discharge Air Sensor monitors leaving air temperature during unit operation 71M57 Sensor − Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48J43 Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30K48 NO START CPC 810-3062 2 Heat/2 Cool Includes: Control Module, Blower Proving Switch, Return Air Sensor, Discharge Air Sensor, Room Sensor (in kits 61J80 and 61J81 Only) and Wiring Harness NO DIRTY FILTER SWITCH ROOM SENSOR (48J43) (30K48) STOP CSI MR88R Control Module/Blower Proving Switch/Return Air Sensor/Discharge Air Sensor/Wiring Harness − Small point count controller, supports free-form modular DDC programming, intelligent I/STAT for independent local analog or digital control, local override and setpoint adjustment, 4 local or global points, integral start/stop schedule, standalone operation, universal inputs (thermistor, voltage, current, contact), 8 relay or low voltage triac outputs, analog outputs, 7 signal inputs plus power, ISTAT port, MR LAN port (RS−485, shielded pair twisted wire), self test diagnostics with LED readout, input point parameters (normal and narrow range, indoor and outdoor temperature range, individual calibration) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71M56 Sensor − Room temperature sensor with microprocessor data communications and power, alphanumeric LCD display for modes selected, mode selection push buttons for (Function, Call, Service, Change and Select), password protection for Service mode, up to 4 global point assignment with red LED’s to indicate (Set Temp., Fan Speed, Room and Outside) . . . . . . . . . . . . . . . . . . . . . I/STAT (Field Furnished) Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30K48 NO START CSI MR88R 2 Heat/2 Cool Includes: Control Module, Blower Proving DIRTY FILTER SWITCH Switch, Return Air Sensor, Discharge Air Sensor and Wiring Harness (30K48) STOP HONEYWELL EXCEL 10 (W7750B) Control Module (W7750B)/Blower Proving Switch/Discharge Air Sensor/Return Air Sensor/Wiring Harness − Standalone control (staged or modulating) of all heating, cooling, mixed air, system fan and economizer functions, up to four stages of heating/cooling combinations, for single zone applications, 6 relay outputs, 2 digital inputs, 1 resistive analog input, network communications, LonMark compliant, configuration options include: supply fan type of air handler, occupancy sensor, window sensor, wall module option, dirty filter monitor, indoor air quality override and smoke control. modes of operation include: occupied, standby, unoccupied, bypass occupied, override modes, start−up and wait, cooling, heating, emergency heat, off mode, disabled mode, smoke emergency, freeze protect, manual position, fan only and disabled. Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Return Air Sensor provides input to module to determine heating or cooling operation and number of stages required. . . . . . . . . . . . . . . . . . . . . . . . . . .. 71M59 Sensor − Room temperature, with setpoint knob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19L21 Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30K48 NO NO START HONEYWELL EXCEL 10 (W7750B) 4 Heat/4 Cool Includes: Control Module, Blower Proving Switch, Discharge Air Sensor, Return Air Sensor and Wiring Harness T7770 ROOM SENSOR DIRTY FILTER SWITCH (19L21) (30K48) STOP L Series Packaged Gas/Electric − 13 to 30 Tons / Page 59 OPTIONAL UNIT CONTROLLERS − Factory or Field Installed JOHNSON METASYS UNT Control Module/Blower Proving Switch/Wiring Harness −Standalone control of all heating, cooling and economizer functions, various operation modes (including: occupied, unoccupied, warmup, standby), network communications, 6 analog inputs, 4 binary inputs, momentary override, zone lighting control, advanced unit diagnostics, indoor air quality control, outdoor air temperature and humidity monitoring, alarm monitoring of: sensors, airflow, economizer, dirty filter, heating /cooling operation, cooling limit, Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Control module may be used in multi−zone applications (i.e. L−Zone). 71M62 (208/230V−3ph) 71M63 (460V−3ph) 71M64 (575V−3ph) Commissioning Tool − Hand−held interface tool, monitor & adjust 36 analog/binary points, carrying case. . . . . . . . . . . . . 60K37 Sensor − Room temperature, phone jack style wiring, quick−mount design, latching door mechanism, setpoint adjustment (warmer/cooler), optional override button, nickel sensors, options for choosing setpoint, indication, mounting and wiring type, plug for handheld commissioning tool (60K36). . . . . . . . . . 42N44 Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . 30K48 NO NO START JOHNSON METASYS UNT 2 Heat/2 Cool Includes: Control Module, Discharge Air Sensor, Return Air Sensor, Blower Proving Switch and Wiring Harness TE-6411 ROOM SENSOR DIRTY FILTER SWITCH (42N44) (30K48) STOP NOVAR ETM−2051 Electronic Thermostat Module (ETM)/Blower Proving Switch/Return Air Sensor/Discharge Air Sensor/Wiring Harness − Module monitors unit operation from different sensors installed in unit and monitors unit diagnostic codes of the IMC. The ETM has outputs for 2 stage heat/2 stage cool, 7 relay outputs: fan Cool 1, Cool 2. Heat 1, Heat 2, Economizer, Night Mode, automatic or continuous blower operation, economizer damper operation and night setback, features: day/occupied mode with low enthalpy (outdoor air damper open), high enthalpy (outdoor air damper closed) or night/unoccupied mode (outdoor air damper closed), network communication (RS−485, shielded pair twisted wire), local override (1 to 255 minutes), watchdog function, fail−safe operation, ETM allows units to be daisy chained" together (up to 31 units) to be operated from one central location with an executive" type control processor (on−site or off−site), built-in time delays, built-in unit operating defaults, diagnostic LED’s indicate various operating functions, surge suppression protects ETM against lightning or voltage spikes, Blower Proving Switch monitors blower operation and locks out unit in case of blower failure, Return Air Sensor provides input to ETM module to determine heating or cooling operation and number of stages required, Discharge Air Sensor monitors leaving air temperature during unit operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71M58 Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30K48 Room Temperature Sensor with Built−in Night Setback Override Button − Provides input to ETM module to determine heating or cooling operation and number of stages required (ordered separately). Override button allows momentary override of night setback during unoccupied mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67K61 Sensor − Remote switch over . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18L36 NO NO NO START NOVAR ETM-2051 2 Heat/2 Cool Includes: Control Module, Blower Proving Switch, Return Air Sensor, Discharge Air Sensor and Wiring Harness ROOM SENSOR W/ NIGHT SETBACK OVERRIDE BUTTON REMOTE SWITCH OVER SENSOR DIRTY FILTER SWITCH (67K61) (18L36) (30K48) STOP NOVAR CUSTOM CONTROLLER Control Module/Blower Proving Switch/Discharge Air Sensor/Room Air Sensor/Wiring Harness − User definable comfort setpoint, on/off and time of day control, cycle II ventilation control . . . . . . 71M65 Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . 30K48 NO START NOVAR CUSTOM CONTROLLER 2 Heat/2 Cool (48K89) Includes: Control Module, Blower Proving DIRTY FILTER SWITCH Switch, Discharge Air Sensor, Room Air Sensor and Wiring Harness (30K48) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 60 STOP OPTIONAL CONVENTIONAL TEMPERATURE CONTROL SYSTEMS − Field Installed Field Installed Catalog No. System and Component Description ELECTRO-MECHANICAL THERMOSTAT Thermostat − Two stage heat & two stage cool with dual temperature levers, subbase choice . . . . . . . Subbase − Manual system switch (Off-Heat-Auto-Cool), fan switch (Auto-On) . . . . . . . . . . . . . . . . . . . Subbase − Non-switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Night Setback Operation − Order components below Heating Thermostat − Single stage heat / Single stage cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Subbase − Non-switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 7 day operation, indicates day and night periods, 2 hour increments, battery back-up . Time Clock − 24 hour night setback operation, 15 minute increments, battery back-up . . . . . . . . . . . . Blower Proving Switch − Monitors blower operation, locks out unit in case of blower failure . . . . . . Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . 13F06 13F17 13F16 12F99 13F16 See Price Book See Price Book 30K49 30K48 NO NON SWITCHING SUBBASE 7 DAY TIME CLOCK (13F16) START ELECTRO MECHANICAL THERMOSTAT (13F06) 2 Heat−2 Cool NIGHT THERMOSTAT 1 Heat/1 Cool NON SWITCHING SUBBASE (12F99) (13F16) NO 24 HOUR TIME CLOCK SWITCHING SUBBASE (13F17) NO BLOWER PROVE SWITCH DIRTY FILTER SWITCH (30K49) (30K48) ELECTRONIC THERMOSTAT Electronic Thermostat − Any two stage heat/ two stage cool electronic thermostat may be used. . . . . . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 7 day operation, indicates day and night periods, 2 hour increments, battery back-up . . . . . . . . . . . . . . . . . . . . . . . . . Time Clock − 24 hour night setback operation, 15 minute increments, battery back-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blower Proving Switch − Monitors blower operation, locks out unit in case of blower failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . STOP See Price Book See Price Book See Price Book 30K49 30K48 LESS ECONOMIZER NO NO START 7 DAY TIME CLOCK *ELECTRONIC ROOM THERMOSTAT 2 Heat−2 Cool WITH ECONOMIZER 24 HOUR TIME CLOCK * Any 2 stage heat/ 2 stage cool electronic thermostat may be used. See Lennox Price Book, Thermostats and Controls, Tab for selection. BLOWER PROVE SWITCH DIRTY FILTER SWITCH (30K49) (30K48) STOP NO PROGRAMMABLE COMMERCIAL THERMOSTAT Thermostat − Programmable, internal or optional remote temperature sensing (sensor required), touch sensitive keyboard, automatic switching, _F or _C readout, no anticipator, droop/no droop selection, indicator LED’s, hour/day programming, override capabilities, time and operational mode readout, stage status indicators, battery back-up, subbase choice, manual system switch (Heat-Off-Auto-Cool), fan switch (Auto-On) . . Subbase − Selectable staging, indicator LED’s, auxiliary relay output for economizer operation 2 Heat / 2 Cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Heat / 3 Cool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − Room temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sensor − Room temperature with 3 hour override and setpoint adjustment . . . . . . . . . . . . . . . . . . . . . . Sensor − Return air temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Blower Proving Switch − Monitors blower operation, locks out unit in case of blower failure . . . . . . Dirty Filter Switch − Senses static pressure increase indicating a dirty filter condition . . . . . . . . . . . . 59N27 37L55 37L53 58C92 86G67 27C40 30K49 30K48 NO SWITCHING SUBBASE (37L55) 2 Heat−2 Cool START ROOM TEMPERATURE SENSOR (59N27) (86G67) SWITCHING SUBBASE NO (58C92) ROOM TEMPERATURE SENSOR W/OVERRIDE T7300 THERMOSTAT NO (37L53) RETURN AIR TEMPERATURE SENSOR 3 Heat−3 Cool (27C40) BLOWER PROVE SWITCH DIRTY FILTER SWITCH (30K49) (30K48) STOP L Series Packaged Gas/Electric − 13 to 30 Tons / Page 61 WEIGHT DATA − 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) Shipping lbs. kg 2555 1159 2760 1252 2685 1218 2880 1306 2735 1241 2940 1334 Net Model Number lbs. 2355 2560 2485 2680 2535 2740 156H/180 Base Unit 156H/180 Max. Unit 210 Base Unit 210 Max. Unit 240/300S Base Unit 240/300S Max. Unit kg 1070 1161 1127 1216 1150 1243 OPTIONS / ACCESSORIES Weight CEILING DIFFUSERS Step−Down p Flush Transitions ECONOMIZER / OUTDOOR AIR / EXHAUST Economizer Barometric Relief Down−Flow Barometric Relief Dampers Horizontal Barometric Relief Dampers Outdoor Air Dampers Damper Section (down−flow) − Motorized Damper Section (down−flow) − Manual Outdoor Air Hood (down−flow) Power Exhaust HEAT EXCHANGER High Fire Heat Exchanger PACKAGING LTL Packaging (less than truck load) ROOF CURBS − STANDARD Down−Flow 14 in. (356 mm) height 24 in. (610 m) height Horizontal 26 in. (660 mm) height 37 in. (940 mm) height 30 in. (762 mm) height 41 in. (1041 mm) height ROOF CURBS − CLIPLOCK 1000 Down−Flow 14 in. (356 mm) height 18 in. (457 mm) height 24 in. (610 mm) height Horizontal 26 in. (660 mm) height 37 in. (940 mm) height 30 in. (762 mm) height 41 in. (1041 mm) height lbs. kg. RTD11−185 RTD11−275 FD11−185 FD11−275 LASRT18 LASRT21/24 392 403 289 363 80 75 178 183 135 165 36 34 LAREMD18/24 86 39 LAGED18/24 LAGEDH18/24 30 20 14 9 LAOADM18/24 52 24 LAOAD18/24 LAOAH18/24 LAPEF18/24 49 65 62 22 29 28 80 36 280 127 LARMF18/36−14 LARMF18/36−24 160 220 73 100 LARMFH18/24−26 LARMFH18/24−37 LARMFH30/36−30 LARMFH30/36−41 420 580 445 725 191 263 202 329 LARMF18/30S−14 LARMF18/30S−18 LARMF18/30S−24 165 193 234 75 88 106 LARMFH18/24S−26 LARMFH18/24S−37 LARMFH30/36S−30 LARMFH30/36S−41 457 491 456 480 207 223 207 218 Base Unit − The unit with low fire heat exchanger NO OPTIONS. Max. Unit − The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Economizer, Power Exhaust Fans, Controls) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 62 WEIGHT DATA − 21, 25, and 30 TON (248H, 300H, and 360H) Shipping lbs. kg 3230 1465 3450 1565 3540 1606 3750 1701 Net Model Number lbs. 3020 3340 3330 3640 248H/300H Base Unit 248H/300H Max. Unit 360 Base Unit 360 Max. Unit kg 1370 1515 1510 1651 OPTIONS / ACCESSORIES Weight lbs. kg. LARTD30/36 LAFD30/36 LASRT30/36 437 414 85 198 188 39 LAREMD30/36 119 54 LAGED30/36 LAGEDH30/36 45 20 20 9 LAOADM30/36 72 33 LAOAD30/36 LAOAH30/36 68 76 31 34 LAPEF30/36 50% High Static − LAPEB30/36DY 100% High Static with or without VFD − LAPEB30/36 99 400 465 45 181 211 80 36 300 136 LARMF18/36−14 LARMF18/36−24 160 220 73 100 LARMFH30/36−30 LARMFH30/36−41 445 725 202 329 LARMF30/36S−14 LARMF30/36S−18 LARMF30/36S−24 149 204 248 68 93 112 LARMFH30/36S−30 LARMFH30/36S−41 456 480 207 218 CEILING DIFFUSERS Step−Down Flush Transitions ECONOMIZER/OUTDOOR AIR Economizer Barometric Relief Down−Flow Barometric Relief Dampers Horizontal Barometric Relief Dampers Outdoor Air Dampers Damper Section (down−flow) − Motorized Damper Section (down−flow) − Manual Outdoor Air Hood (down−flow) Power Exhaust Power Exhaust HEAT EXCHANGER High Fire Heat Exchanger PACKAGING LTL Packaging (less than truck load) ROOF CURBS − STANDARD Down−Flow 14 in. (356 mm) height 24 in. (610 m) height Horizontal 30 in. (762 mm) height 41 in. (1041 mm) height ROOF CURBS − CLIPLOCK 1000 Down−Flow 14 in. (356 mm) height 18 in. (457 mm) height 24 in. (610 mm) height Horizontal 30 in. (762 mm) height 41 in. (1041 mm) height Base Unit − The unit with low fire heat exchanger NO OPTIONS. Max. Unit − The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Economizer, Power Exhaust Fans, Controls) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 63 DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) CORNER WEIGHTS Model Number AA BB CENTER OF GRAVITY CC DD EE FF lbs. kg lbs. kg lbs. kg lbs. kg inch mm inch 156H/180 Base Unit 470 213 470 213 650 295 650 295 50 1270 38−1/2 978 156H/180 Max. Unit 580 263 590 268 700 318 690 313 54 1372 41-1/2 1054 210 Base Unit 480 218 460 209 680 308 710 322 52-1/2 1334 37 940 210 Max. Unit 610 277 590 268 730 331 750 304 52-1/2 1334 41 1041 240/300S Base Unit 490 222 520 236 740 336 710 322 54-1/2 1384 37-1/2 953 349 53 1346 40-1/2 1029 240/300S Max. Unit 610 277 610 277 750 304 770 mm BB AA 4-1/4 (108) 12-3/8 (314) 15 (381) 18 (457) BOTTOM RETURN AIR OPENING BOTTOM SUPPLY AIR OPENINGS 28 (711) 20 (508) 12-3/8 (314) 60-1/2 (1537) 4-1/2 (114) 28 (711) 20 (508) EE CENTER OF GRAVITY FF 4 (102) DD CC BOTTOM POWER ENTRY 5 X 8 inches (127 X 203 mm) 4 (102) TOP VIEW OPTIONAL DISCONNECT (Factory Installed) 132-5/8 (3369) GAS SUPPLY INLET (For Bottom Gas Supply Only) 90-1/8 (2289) OPTIONAL 115 VOLT OUTLET (Factory Installed Inside Unit) 54-1/4 (1378) FLUE OUTLET 51 (1295) 19-3/8 (492) 1-1/2 (38) 5-3/8 (137) 31-1/2 (800) SIDE ELECTRICAL INLETS 3-1/4 (83) CONDENSATE DRAIN 91-1/8 (2315) END VIEW L Series Packaged Gas/Electric − 13 to 30 Tons / Page 64 GAS SUPPLY INLET OPTIONAL OUTDOOR GRILLE KIT (Field Installed) (Both Sides) 5-7/8 (149) LIFTING HOLES (For Rigging Front and Back) FORKLIFT SLOTS (Front and Left Side Only) 107-3/4 (2737) SIDE VIEW 25-3/8 (645) ACCESSORY DIMENSIONS − INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 16 (406) OPTIONAL OUTDOOR AIR HOOD (Factory or Field Installed) Required with Economizer or Outdoor Air Damper 1 OPTIONAL STANDARD STATIC POWER EXHAUST FANS HOOD (Field Installed) 1 Field Installed in Return Air Duct for Horizontal Applications. HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal return air duct adjacent to unit) 31−5/8 (803) 29−1/2 (749) 6-1/2 (165) FRONT VIEW SIDE VIEW 1 14-1/2 (368) 1 13 (330) NOTE − Two furnished per order no. 1 NOTE − Opening size required in return air duct. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 65 ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) STANDARD ROOF CURBS − DOUBLE DUCT OPENING 1-13/16 (46) 1-13/16 (46) 102-1/8 (2594) 98-1/2 (2502) Frame Opening 8−1/4 (210) 61−1/2 (1562) 16 (406) NAILER STRIP (Furnished) CURB RETURN AIR OPENING 17 (432) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 3/4 (19) Typ. 82-5/8 (2099) 86-1/8 (2188) 1-13/16 (46) Frame Opening 102-1/2 (2604) 61-1/2 (1562) 8−1/4 (210) NOTE Roof deck may be omitted within confines of curb. CURB SUPPLY AIR OPENING 21 (533 ) SIDE VIEW 1-13/16 (46) A 1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 A NAILER STRIP (Furnished) 2 (51) SECTION A-A 1-13/16 (46) TOP VIEW CLIPLOCK 1000 ROOF CURBS − DOUBLE DUCT OPENING 16" (406.4) 86−1/4" (2190.75) 21" (533.4) 102−1/8" (2593.975) 8−1/4" (209.55) 81−1/2" (2070.1) 61−1/2" (1562.1) 17" (431.8) 98−1/2" (2501.9) RETURN AIR OPENING 8−1/4" (209.55) SUPPLY AIR OPENING 14 (356) 18 (457) 24 (610) 61−1/2" (1562.1) DISCARD DUCT SUPPORT WHEN USING FOR OTHER THAN LARMF − 18/36 2" MIN. FACTORY INSTALLED PERIMETER WOOD NAILER STRIP CORNER DETAIL TOP EDGE WOOD NAILER STRIP BOTTOM FLANGE TYPICAL SLOT TYPICAL LOCKING TAB L Series Packaged Gas/Electric − 13 to 30 Tons / Page 66 ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) STANDARD ROOF CURBS WITH SUPPLY & RETURN AIR TRANSITIONS FOR CEILING DIFFUSERS 1-13/16 (46) 102-1/8 (2594) 98-1/2 (2502) 1-13/16 (46) Frame Opening 69-1/4 (1759) 1-13/16 (46) TRANSITION DETAIL 26-1/2 (673) LASRT RETURN TRANSITION Frame Opening RETURN AIR OPENING SUPPORT ANGLE (Furnished with Transitions) A B 8 (203) 54 (1372) 4-1/2 (114) 82-5/8 (2099) 69-1/4 (1759) A SUPPLY AIR OPENINGS 86-1/8 (2188) A 2 (51) B 1-1/2 Typ. (38) B LASRT SUPPLY TRANSITION 1-13/16 (46) 1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 NAILER STRIP (Furnished) 3/4 Typ. (19) A TRANSITION OPENING SIZES A 2 (51) SECTION A-A 1-13/16 (46) TOP VIEW INSULATION (Furnished) 10 8 (203) (254) NAILER STRIP (Furnished) 2 (51) A B Model Number inch mm inch mm LASRT18 18 457 36 914 LASRT21/24 24 610 48 1219 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 102-1/2 (2604) NOTE Roof deck may be omitted within confines of curb. SIDE VIEW ROOF CURB SPECIFICATIONS TYPICAL FLASHING DETAIL FOR ROOF CURBS Roof Curb is rigid enough to be spanned over its entire length or cantilevered if supported on both sides of center of gravity. Roof Curb 1 Moment of inertia (I) (in.4) (cm4) 1 Section modulus I (in.3) (cm3) C Curb weight. (lb/ft) (kg/m) of length Design strength (psi) (kPa) 1 UNIT BASE BOTTOM LARMF18/36-14 LARMF18/36-24 39 (1634) 160 (6639) 5.5 (90) 13.1 (512) 5.5 (8.2) 8.5 (12.7) 20,000 (137,900) UNIT BASE RAIL FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) Includes both sides of curb. CANT STRIP (Field Supplied) ROOFING MATERIAL RIGID INSULATION (Field Supplied) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 67 ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) HORIZONTAL ROOF CURBS − Requires Optional Horizontal Return Air Panel Kit 102-1/8 (2594) 1-13/16 (46) 1-13/16 (46) 98-1/2 (2502) 1-13/16 (46) Frame Opening NOTE LARMFH18/24-26 and LARMFH30/36-30 are designed for horizontal discharge when unit is mounted on a slab. LARMFH18/24-37 and LARMFH30/36-41 are designed for horizontal discharge when unit is mounted on a rooftop. Opening Frame 1-13/16 (46) 1 2 3 4 1 (25) 26 (660) 37 (940) 30 (762) 41 (1041) A A NAILER STRIP (Furnished) 2 (51) PANEL TO COVER RETURN AIR OPENING IN BOTTOM OF UNIT (Furnished With Optional Horizontal Return Air Panel Kit) SECTION A-A 82-5/8 (2099) 98-1/2 (2502) 86-1/8 (2188) 54 (1372) SUPPLY AIR TURNING VANE (Furnished) SIDE VIEW NOTE − Roof deck may be omitted within confines of curb. 1,2 3,4 TOP VIEW 1-13/16 (46) (PACKAGED UNIT) 8-1/4 (210) 13-1/4 (337) NAILER STRIP (Furnished) 86-1/4 (2191) 102-1/8 (2594) 5-1/2 (140) 1 2 3 4 75 26 (660) 37 (940) 30 (762) 41 (1041) CURB SUPPLY (1905) AIR OPENING With 1-1/2 in. (38 mm) FLANGE 1,2 3,4 1,3 2,4 SUPPLY AIR TURNING VANE (Furnished) 14 (356) 18 (457) 6-1/2 (165) 17-1/2 (445) 86-5/8 (2200) 102-1/2 (2604) FRONT VIEW 2 1 LARMFH18/24-26 LARMFH18/24-37 3 SUPPLY DUCT PANELS (Furnished) SIDE VIEW 4 LARMFH30/36-40 LARMFH30/36-30 (used with 300S/300H/360 Models) (used with 300S/300H/360 Models) HORIZONTAL SUPPLY AND RETURN AIR OPENINGS WITH HORIZONTAL ROOF CURB OPTIONAL RETURN AIR PANEL KIT (Required For Horizontal Applications) 54-1/4 (1378) 1 2 3 4 76-1/4 (1937) 87-1/4 (2216) 80-1/4 (2038) 91-1/4 (2318) 12-3/8 (314) 60-1/2 (1537) 15 (381) HORIZONTAL RETURN AIR OPENING 2 (51) 1 2 3 4 22 (559) 33 (838) 26 (660) 37 (940) NOTE − Top of Roof Curb extends 4 inch (102 mm) inside bottom of unit base. See Typical flashing detail. 30-3/8 (772) 75 (1905) HORIZONTAL 1,2 14 (356) SUPPLY AIR OPENING 3,4 18 (457) HORIZONTAL ROOF CURB (Required For Horizontal Applications) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 68 1 2 3 4 1,3 2,4 6-1/2 (165) 17-1/2 (445) LARMFH18/24-26 LARMFH18/24-37 LARMFH30/36-30 (used with 300S Models Only) LARMFH30/36-40 (used with 300S Models Only) 1,2 3,4 8-1/4 (210) 13-1/4 (337) ACCESSORY DIMENSIONS − INCHES (MM) 13, 15, 17.5, 20, and 25 TON (156H, 180, 210, 240, and 300S) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS STEP-DOWN CEILING DIFFUSER H FLUSH CEILING DIFFUSER E 4−5/8 (117) G G F 4−13/16 (122) F 2 (51) C 4−5/8 (117) E B E D 4−13/16 (122) 2 (51) A A C K G B D Model Number A B C D E F G H K RTD11−185 RTD11−275 in. 34 40 mm 864 1016 in. 23−7/8 28−7/8 mm 606 225 in. 10−1/8 11−1/8 mm 257 283 in. 47−5/8 59−5/8 mm 1210 1514 in. 45−5/8 57−7/8 mm 1159 1470 in. 36 48 mm 914 1219 in. 18 24 Model Number A B C D E F in. FD11−185 FD11−275 30−1/8 36−1/8 mm 613 918 in. 47−5/8 59−5/8 mm 1210 1514 in. 45−5/8 57−5/8 mm 1159 1464 in. 36 48 mm 914 1219 in. 18 24 mm 457 610 in. 45−5/8 57−5/8 mm 457 610 mm 1159 1464 in. 45−5/8 57−5/8 in. 47−5/8 59−5/8 mm 1159 1464 mm 1210 1521 in. 47−5/8 59−5/8 mm 1210 1521 G L Series Packaged Gas/Electric − 13 to 30 Tons / Page 69 DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) Shown With Optional Economizer Dampers, Power Exhaust Fans, Convenience Outlet, Unit Disconnect CORNER WEIGHTS Model Number AA BB CENTER OF GRAVITY CC DD EE FF lbs. kg lbs. kg lbs. kg lbs. kg inch mm inch 248H/300H Base Unit 588 267 630 286 932 423 870 395 62-5/8 1591 36-3/4 mm 933 248H/300H Max. Unit 716 325 743 337 958 335 923 419 61-1/4 1556 39-3/4 1010 360 Base Unit 656 298 639 290 1004 455 1031 468 59-3/4 1518 35-3/8 899 360 Max. Unit 785 356 740 336 1025 465 1090 494 58-7/8 1495 38-1/4 972 ACCESSORY SHIPPING WEIGHTS (add to base unit weight) High Fire Heat Exchange 80 lbs. 36 kg Power Exhaust 90 lbs. 41 kg Economizer + Hood 195 lbs. 88 kg LTL Packaging (less than truck load) 300 lbs. 136 kg Outdoor Air Damper + Hood 148 lbs. 67 kg Base Unit − The unit with low fire heat exchanger NO OPTIONS. Max. Unit − The unit with ALL OPTIONS Installed. (High Input Heat Exchanger, Economizer, Power Exhaust Fans, Controls) EE 4-1/4 (108) AA 5-3/4 (146) BB 15 (381) 78-1/2 (1994) 18 (457) 17-1/2 (445) BOTTOM RETURN AIR OPENING CENTER OF GRAVITY 28 28 (711) (711) 4-1/2 20 (508) 20 (508) (114) FF BOTTOM SUPPLY AIR OPENINGS 4 (102) DD CC BOTTOM POWER/GAS ENTRY 5 X 8 inches (127 X 203 mm) 4 (102) TOP VIEW OPTIONAL 115 VOLT OUTLET (Factory Installed Inside Unit) 145 (3683) 90-1/8 (2289) OPTIONAL DISCONNECT (Factory Installed) 65 (1651) SIDE ELECTRICAL INLETS 61-3/4 (1568) CONDENSATE DRAIN 91-1/8 (2315) END VIEW L Series Packaged Gas/Electric − 13 to 30 Tons / Page 70 FLUE OUTLET OPTIONAL OUTDOOR GRILLE KIT (Field Installed) (Both Sides) 5-3/4 (146) 5-3/8 (137) 31-1/2 (800) GAS SUPPLY INLET (For Bottom Gas Supply Only) 3-1/4 (83) 4 (102) FORKLIFT SLOTS (Front and Left Side Only) 119−3/4 (3042) SIDE VIEW LIFTING HOLES (For Rigging Front and Back) 25-3/4 (654) ACCESSORY DIMENSIONS − INCHES (MM) OPTIONAL OUTDOOR AIR HOOD DETAIL WITH STANDARD STATIC POWER EXHAUST FANS 16 (406) OPTIONAL OUTDOOR AIR HOOD (Factory or Field Installed) Required with Economizer or Outdoor Air Damper 1 OPTIONAL STANDARD STATIC POWER EXHAUST FANS HOOD (Field Installed) 1 Field Installed in Return Air Duct for Horizontal Applications. OPTIONAL HIGH STATIC POWER EXHAUST FANS DETAIL 13−3/4 (349) 28 (711) OPTIONAL HIGH STATIC POWER EXHAUST FANS (Field Installed) HORIZONTAL BAROMETRIC RELIEF DAMPERS (Field installed in horizontal return air duct adjacent to unit) 54−1/2 (1384) 52−1/2 (1334) 6-1/2 (165) 1 14-1/2 (368) 1 13 (330) FRONT VIEW SIDE VIEW NOTE − Two furnished per order no. 1 NOTE − Opening size required in return air duct. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 71 ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) STANDARD ROOF CURBS − DOUBLE DUCT OPENING 1-13/16 (46) 1-13/16 (46) 1-13/16 (46) 102-1/8 (2594) 98-1/2 (2502) Frame Opening 79-1/2 (2019) Frame Opening 1-3/4 (44) CURB RETURN AIR OPENING 16 (406) 17 (432) NAILER STRIP (Furnished) 3/4 (19) Typ. 82-5/8 (2099) 86-1/8 (2188) 13-1/4 (337) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 61-1/2 (1562) 21 (533) CURB SUPPLY AIR OPENINGS 102-1/2 (2604) NOTE Roof deck may be omitted within confines of curb. 1-13/16 (46) 1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 A SIDE VIEW A NAILER STRIP (Furnished) 2 (51) SECTION A-A 1-13/16 (46) TOP VIEW CLIPLOCK 1000 ROOF CURBS − DOUBLE DUCT OPENING 1−3/4" (44.45) 16" (406.4) 86−1/4" (2190.75) 21" (533.4) 114" (2895.6) 81−1/2" (2070.1) 79−1/2" (2019.3) 17" (431.5) 110−3/8" (2803.525) RETURN AIR OPENING 13−1/4" (336.55) SUPPLY AIR OPENING 14 (356) 18 (457) 24 (610) 61−1/2" (1562.1) FACTORY INSTALLED PERIMETER WOOD NAILER STRIP CORNER DETAIL TOP EDGE WOOD NAILER STRIP 2" MIN. (50.8) BOTTOM FLANGE TYPICAL SLOT TYPICAL LOCKING TAB L Series Packaged Gas/Electric − 13 to 30 Tons / Page 72 ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) STANDARD ROOF CURBS WITH SUPPLY & RETURN AIR TRANSITIONS FOR CEILING DIFFUSERS 102-1/8 (2594) 1-13/16 (46) 1-13/16 (46) 98-1/2 (2502) ROOF CURB DETAIL 1-13/16 (46) Frame Opening 80-3/4 (2051) 1-13/16 (46) B 28 (711) 60 (1524) 82-5/8 (2099 ) LASRT RETURN TRANSITION Frame Opening RETURN AIR OPENING 1 (25) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 SUPPORT ANGLE (Furnished with Transitions) 2 (51) 54 (1372) SECTION A-A 4-1/2 (114) SUPPLY AIR OPENINGS 28 (711) TRANSITION DETAIL LASRT SUPPLY TRANSITION 60 (1524) 86-1/8 (2188) 1-1/2 Typ. (38) 3/4 Typ. (19) A B 14 12 (305) (356 ) A 26-1/2 (673) 26-1/2 (673) LASRT SUPPLY TRANSITION LASRT RETURN TRANSITION 2 (51) 28 (711) TOP VIEW 1-13/16 (46) NAILER STRIP (Furnished) 4-1/2 (114) 28 (711) SECTION B-B INSULATION (Furnished) 14 12 (305) (356 ) 2 (51) NAILER STRIP (Furnished) 14 (356) LARMF18/36-14 24 (610) LARMF18/36-24 102-1/2 (2604) NOTE Roof deck may be omitted within confines of curb. SIDE VIEW ROOF CURB SPECIFICATIONS TYPICAL FLASHING DETAIL FOR ROOF CURBS Roof Curb is rigid enough to be spanned over its entire length or cantilevered if supported on both sides of center of gravity. Roof Curb 1 Moment of inertia (I) (in.4) (cm4) 1 Section modulus I (in.3) (cm3) C Curb weight. (lb/ft) (kg/m) of length Design strength (psi) (kPa) 1 UNIT BASE BOTTOM LARMF18/36-14 LARMF18/36-24 39 (1634) 160 (6639) 5.5 (90) 13.1 (512) 5.5 (8.2) 8.5 (12.7) 20,000 (137,900) UNIT BASE RAIL FIBERGLASS INSULATION (Furnished) COUNTER FLASHING (Field Supplied) NAILER STRIP (Furnished) ROOF CURB (Extends around entire perimeter of unit) Includes both sides of curb. CANT STRIP (Field Supplied) ROOFING MATERIAL RIGID INSULATION (Field Supplied) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 73 ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) HORIZONTAL ROOF CURBS − Requires Optional Horizontal Return Air Panel Kit 102-1/8 (2594) 1-13/16 (46) 1-13/16 (46) 98-1/2 (2502) 1-13/16 (46) Frame Opening NOTE LARMFH30/36-30 is designed for horizontal discharge when unit is mounted on a slab. LARMFH30/36-41 is designed for horizontal discharge when unit is mounted on a rooftop. 1 2 3 4 Opening Frame 1-13/16 (46) 1 (25) 26 (660) 37 (940) 30 (762) 41 (1041) A A NAILER STRIP (Furnished) 2 (51) PANEL TO COVER RETURN AIR OPENING IN BOTTOM OF UNIT (Furnished With Optional Horizontal Return Air Panel Kit) SECTION A-A 82-5/8 (2099) 98-1/2 (2502) 86-1/8 (2188) 54 (1372) SUPPLY AIR TURNING VANE (Furnished) SIDE VIEW NOTE − Roof deck may be omitted within confines of curb. 1-13/16 (46) (PACKAGED UNIT) 1,2 3,4 TOP VIEW 8-1/4 (210) 13-1/4 (337) NAILER STRIP (Furnished) 86-1/4 (2191) 102-1/8 (2594) 5-1/2 (140) 1 2 3 4 26 (660) 37 (940) 30 (762) 41 (1041) 75 (1905) CURB SUPPLY AIR OPENING With 1-1/2 in. (38 mm) FLANGE 1,3 2,4 1,2 3,4 SUPPLY AIR TURNING VANE (Furnished) 14 (356) 18 (457) 6-1/2 (165) 17-1/2 (445) 86-5/8 (2200) 102-1/2 (2604) FRONT VIEW 1 LARMFH18/24-26 2 LARMFH18/24-37 3 SUPPLY DUCT PANELS (Furnished) SIDE VIEW LARMFH30/36-30 (used with 248H/300S/300H/360 Models) 4 LARMFH30/36-40 (used with 248H/300S/300H/360 Models) HORIZONTAL SUPPLY AND RETURN AIR OPENINGS ROOFTOP UNIT WITH HORIZONTAL ROOF CURB OPTIONAL RETURN AIR PANEL KIT (Required For Horizontal Applications 65 (1651) 91 (2311) LARMFH30/36-30 102 (2591) LARMFH30/36-41 78-1/2 (1994) 15 (381) HORIZONTAL RETURN AIR OPENING 5-1/4 (133) 2 (51) 1 26 (660) LARMFH30/36-30 37 (9401) LARMFH30/36-41 75 (1905) 1 1 NOTE − Top of Curb extends 4 inch (102 mm) inside bottom of unit base. See Typical Flashing Detail. HORIZONTAL SUPPLY AIR OPENING 42-7/8 (1089) HORIZONTAL ROOF CURB (Required For Horizontal Applications) SIDE VIEW (Horizontal Openings) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 74 18 (457) 13-1/4 (337) 6-1/2 (165) LARMFH30/36-30 17-1/2 (445) LARMFH30/36-41 ACCESSORY DIMENSIONS − INCHES (MM) 21, 25, and 30 TON (248H, 300H, and 360H) COMBINATION CEILING SUPPLY AND RETURN DIFFUSERS LARTD30/36 STEP-DOWN CEILING DIFFUSER 63−5/8 (1616) 4−5/8 (117) 28 28 (711) (711) 63−5/8 (1616) 1−13/16 60 (46) (1524) LAFD30/36 FLUSH CEILING DIFFUSER 2 (51) 63−5/8 (1616) 4−5/8 (117) 28 28 (711) (711) 63−5/8 (1616) 1−13/16 60 (46) (1524) 38−7/8 51 (987)(1295) 2 (51) 46 (1168) 12−1/8 (308) 65−5/8 (1667) 65−5/8 (1667) 65−5/8 (1667) 65−5/8 (1667) L Series Packaged Gas/Electric − 13 to 30 Tons / Page 75 GUIDE SPECIFICATIONS This MANU−SPEC® utilizes the Construction Specifications Institute (CSI) Manual of Practice, including MasterFormatt, SectionFormatt and PageFormatt. A MANU−SPEC is a manufacturer−specific proprietary product specification using the proprietary method of specifying applicable to project specifications and master guide specifications. Optional text is indicated by brackets [ ]; delete optional text in final copy of specification. Specifier Notes typically precede specification text; delete notes in final copy of specification. Trade/brand names with appropriate symbols typically are used in Specifier Notes; symbols are not used in specification text. Metric conversion, where used, is soft metric conversion. This MANU−SPEC specifies Lennox L Series® Rooftop Units. These products are manufactured by Lennox Industries Inc. Revise MANU−SPEC section number and title below to suit project requirements, specification practices and section content. Refer to CSI MasterFormat for other section numbers and titles. SECTION 15730 UNITARY AIR CONDITIONING EQUIPMENT PART 1 GENERAL PART 1.01 A. SUMMARY Section Includes: Packaged rooftop units and commercial packaged, gas/electric and electric/electric heat pumps. Specifier Note: Revise paragraph below to suit project requirements. Add section numbers and titles per CSI MasterFormat and specifier’s practice. B. Related Sections: Specifier Note: Article below may be omitted when specifying manufacturer’s proprietary products and recommended installation. Retain Reference Article when specifying products and installation by an industry reference standard. If retained, list standard(s) referenced in this section. Indicate issuing authority name, acronym, standard designation and title. Establish policy for indicating edition date of standard referenced. Conditions of the Contract or Division 1 References Section may establish the edition date of standards. This article does not require compliance with standard, but is merely a listing of references used. Article below should list only those industry standards referenced in this section. Retain only those reference standards to be used within the text of this Section. Add and delete as required for specific project. PART 1.02 A. B. C. REFERENCES American National Standards Institute (ANSI): 1. ANSI/ASHRAE 15 Safety Standard for Refrigeration Systems. 2. ANSI/ASHRAE/IESNA 90.1 Energy Efficient Design of New Buildings Except Low−Rise Residential Buildings. 3. ANSI Z21.47 Gas−Fired Central Furnaces. Air−Conditioning and Refrigeration Institute (ARI): 1. ARI 210/240 Unitary Air−Conditioning and Air−Source Heat Pump Equipment. 2. ARI 270 Sound Rating of Outdoor Unitary Equipment. 3. ARI 340/360 Commercial and Industrial Unitary Air−Conditioning and Heat Pump Equipment. 4. ARI 370 Sound Rating of Large Outdoor Refrigerating and Air Conditioning Equipment. American Society of Heating, Refrigerating, and Air−Conditioning Engineers, Inc. (ASHRAE): 1. ASHRAE 52.2 Method of Testing General Ventilation Air−Cleaning Devices for Removal Efficiency by Particle Size (ANSI approved). 2. ASHRAE 62.1 Ventilation for Acceptable Indoor Air Quality. D. U.S. Energy Policy Act of 1992 (EPACT). E. U.S. National Appliance Energy Conservation Act (NAECA): 1. F. National Fire Protection Association (NFPA): 1. G. NAECA 1988. NFPA 90A Installation of Air Conditioning and Ventilation Systems. Underwriters Laboratories, Inc. (UL): 1. UL 1995 Standard for Safety for Heating and Cooling Equipment. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 76 GUIDE SPECIFICATIONS Specifier Note: Article below should be restricted to statements describing design or performance requirements and functional (not dimensional) tolerances of a complete system. Limit descriptions to composite and operational properties required to link components of a system together and to interface with other systems. PART 1.03 SYSTEM DESCRIPTION A. Design Requirements: Provide products and systems that have been manufactured, fabricated and installed to following criteria: 1. ANSI/ASHRAE/IESNA 90.1. 2. ANSI Z21.47. 3. UL 1995. B. Performance Requirements: 1. Packaged Gas Electric: a. Natural Gas Supply Pressure: 7 in. w.c. (1.7 kPa). b. LPG/Propane Supply Pressure: 11 in. w.c. (2.7 kPa). Specifier Note: Specify 208/230 V or 460 V or 575 V, 3−phase for L Series® units from 6 − 30 ton (21.1 − 105.6 kW). Specify 208/230 V, 1−phase, 208/230 V, 460 V, or 575 V, 3−phase for L Series® units from 3 − 5 ton (10.6 − 17.6 kW). 2. Packaged Cooling: a. Electrical Requirements for Direct Drive Blowers: 60 hz, [208/230 V, 1−phase] [208/230 V, 3−phase] [460 V, 3−phase] [575 V, 3−phase]. Specifier Note: For belt drive blowers from models LCC072S, LCA072H, LCC090S, LCA090H, LCC102S, LCA102H, LCC156H, LCC180S, LCC180H, LCC210S, LCC210H, LCC240S, LCA240H, LCC300S, LCC300H, LCA360H, and LCC360H single phase is not an option. b. Electrical Requirements for Belt Drive Blowers: 60 hz, [208/230 V, 1−phase] [208/230 V, 3−phase] [460 V, 3−phase] [575 V, 3−phase]. Specifier Note: Available Heat Pump units include LHA090, LHC090, LHA240 and LHC240 only. 3. Packaged Heat Pumps: a. Electrical Requirements: 60 hz, [208/230 V, 3−phase] [460 V, 3−phase] [575 V, 3−phase]. 4. ARI Rated Net Cooling Efficiency: To meet or exceed ASHRAE Standard 90.1 at rated airflow not less than 350 cfm/ton. Specifier Note: Article below includes submittal of relevant data to be furnished by Contractor before, during or after construction. Coordinate this article with Architect’s and Contractor’s duties and responsibilities in Conditions of the Contract and Division 1 Submittal Procedures Section. PART 1.04 SUBMITTALS A. General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures. B. Product Data: Submit product data, including manufacturer’s SPEC−DATA® product sheet, for specified products. C. Shop Drawings: 1. Submit shop drawings in accordance with Section 01330 − Submittal Procedures. 2. Indicate: a. Equipment, piping and connections, together with valves, strainers, control assemblies, thermostatic controls, auxiliaries and hardware, and recommended ancillaries which are mounted, wired and piped ready for final connection to building system, its size and recommended bypass connections. b. Piping, valves and fittings shipped loose showing final location in assembly. c. Control equipment shipped loose, showing final location in assembly. d. Dimensions, internal and external construction details, recommended method of installation with proposed structural steel support, mounting curb details, sizes and location of mounting bolt holes; include mass distribution drawings showing point loads. e. Detailed composite wiring diagrams for control systems showing factory installed wiring and equipment on packaged equipment or required for controlling devices or ancillaries, accessories and controllers. f. Details of vibration isolation. g. Estimate of sound levels to be expected across individual octave bands in dB. h. Type of refrigerant used. D. Quality Assurance: 1. Test Reports: Certified test reports showing compliance with specified performance characteristics and physical properties. 2. Certificates: Product certificates signed by manufacturer certifying materials comply with specified performance characteristics and criteria and physical requirements. 3. Manufacturer’s Instructions: Manufacturer’s installation instructions. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 77 GUIDE SPECIFICATIONS Specifier Note: Coordinate paragraph below with Part 3 Field Quality Requirements Article herein. Retain or delete as applicable. E. Manufacturer’s Field Reports: Manufacturer’s field reports specified. F. Closeout Submittals: Submit the following: 1. Warranty: Warranty documents specified. 2. Operation and Maintenance Data: Operation and maintenance data for installed products in accordance with Division 1 Closeout Submittals (Maintenance Data and Operation Data) Section. Include methods for maintaining installed products and precautions against cleaning materials and methods detrimental to finishes and performance. Include names and addresses of spare part suppliers. 3. Provide brief description of unit, with details of function, operation, control and component service. 4. Commissioning Report: Submit commissioning reports, report forms and schematics in accordance with Section 01810 − Commissioning. PART 1.05 A. QUALITY ASSURANCE Qualifications: 1. Installer experienced in performing work of this section who has specialized in installation of work similar to that required for this project. 2. Manufacturer Qualifications: Manufacturer capable of providing field service representation during construction and approving application method. Specifier Note: Paragraph below should list obligations for compliance with specific code requirements particular to this section. General statements to comply with a particular code are typically addressed in Conditions of the Contract and Division 1 Regulatory Requirements Section. Repetitive statements should be avoided. Current data on building code requirements and product compliance may be obtained from filter manufacturer technical support specialists. B. C. Regulatory Requirements: Provide [Packaged gas electric] [Packaged cooling] [Packaged heat pump] that complies with the following requirements: 1. ARI 210/240. 2. ARI 270. 3. ARI 340/360. 4. ASHRAE 52.2. 5. NFPA 90A. Preinstallation Meetings: Conduct preinstallation meeting to verify project requirements, manufacturer’s installation instructions and manufacturer’s warranty requirements. Comply with Division 1 Project Management and Coordination (Project Meetings). PART 1.06 DELIVERY, STORAGE & HANDLING A. General: Comply with Division 1 Product Requirements. B. Ordering: Comply with manufacturer’s ordering instructions and lead time requirements to avoid construction delays. C. Packing, Shipping, Handling and Delivery: D. PART 1.07 A. 1. Deliver materials in manufacturer’s original, unopened, undamaged containers with identification labels intact. 2. Ship, handle and unload units according to manufacturer’s instructions. Storage and Protection: 1. Store materials protected from exposure to harmful weather conditions. 2. Factory shipping covers to remain in place until installation. PROJECT CONDITIONS Installation Location: [Confirm design conditions and temperature.]. Specifier Note: Coordinate article below with Conditions of the Contract and with Division 1 Closeout Submittals (Warranty). PART 1.08 WARRANTY A. Project Warranty: Refer to Conditions of the Contract for project warranty provisions. B. Manufacturer’s Warranty: Submit, for Owner’s acceptance, manufacturer’s standard warranty document executed by authorized company official. Manufacturer’s warranty is in addition to, and not a limitation of, other rights Owner may have under Contract Documents. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 78 GUIDE SPECIFICATIONS Specifier Note: Coordinate paragraph below with manufacturer’s warranty requirements. C. Warranty: Commencing on Date of Installation. 1. Compressors: 5 years (limited). 2. Integrated Modular Control: 3 years (limited). 3. Other System Components: 1 year (limited). 4. Aluminized Heat Exchangers: 10 years (limited). 5. Stainless Steel Heat Exchangers: 15 years (limited). PART 2 PRODUCTS Specifier Note: Retain article below for proprietary method specification. Add product attributes, performance characteristics, material standards and descriptions as applicable. Use of such phrases as or equal" or or approved equal" or similar phrases may cause ambiguity in specifications. Such phrases require verification (procedural, legal and regulatory) and assignment of responsibility for determining or equal" products. PART 2.01 A. ROOFTOP UNITS Manufacturer: Lennox Industries Inc. 1. B. Contact: 2100 Lake Park Blvd., Richardson, TX 75080; Telephone: (800) 453−6669; website: www.lennox.com. Proprietary Products/Systems: Lennox L Series® Unitary Air Conditioning Equipment, including the following equipment: 1. Cabinet: Weatherproofing tested and certified to AGA [Rain test standards] and soundproofing tested to ARI 270, dbA at [______] y (______) y (______) m free field. a. Heavy gauge steel panels and full perimeter heavy gauge galvanized steel base rails. b. Raised edges around duct and power entry openings in bottom of unit. c. Airflow Configuration: [Down−flow (vertical) return air] [Horizontal return airflow with Horizontal Roof Mounting Frame] [And Horizontal Return Air Panel Kit (required when converting down−flow configured unit to horizontal airflow)]. d. Power Entry: Electrical [And gas] lines brought through unit base or through horizontal access knockouts. e. Exterior Panels: Constructed of heavy gauge, galvanized steel with 2−layer enamel paint finish. f. Insulation: All panels adjacent to conditioned air fully insulated with non−hygroscopic fiberglass insulation. Unit base fully insulated. g. Base Rail: Full perimeter base rail with rigging holes; 3 sides with fork slots. h. Access Panels: Hinged for compressor/controls/heating areas, blower access and air filter/economizer access; and, sealed with quarter−turn latching handles and tight air and water seal. 2. Compressor: 3. Fans, General: Centrifugal, forward curved impellers, statically and dynamically balanced. [Multi] V−belt drive with adjustable variable pitch motor pulley. a. Copeland scrollt type, hermetically sealed. a. Condenser Fan: Low sound operating, PVC coated fan guard, direct drive propeller type fans to discharge vertically. b. Condenser Fan Motor: Permanently lubricated, permanent split capacitor; totally enclosed from weather, dust and corrosion; permanently lubricated ball bearings; resiliently mounted; overload protected. 4. Evaporator Coils: Pressure and leak tested to 500 psi (3445 kPa), nonferrous coils with enhanced aluminum fins mechanically bonded to durable copper tubes. 5. Condenser Coils: a. Pressure and leak tested to 500 psi (3445 kPa), nonferrous coils with enhanced aluminum fins mechanically bonded to durable copper tubes. Specifier Note: Specify slab construction for L Series® over 6 tons (21.1 kW), excluding heat pumps. b. 6. [Formed construction] [Slab construction]. Air Distribution: a. Equipment capable of down−flow (vertical) or side (horizontal) handling of conditioned air. b. Optional Equipment: L Series Packaged Gas/Electric − 13 to 30 Tons / Page 79 GUIDE SPECIFICATIONS Specifier Note: The following kit is required for horizontal air handling for L Series® 3 − 12 ton (10.6 − 42.2 kW) models. 1) Horizontal conversion kit for horizontal air handling. Specifier Note: The following kit is required for horizontal air handling for L Series®, 13 − 30 ton (45.8 − 105.6 kW) models. 2) 7. Horizontal return air panel kit and horizontal roof mounting frame for horizontal air handling. Filters: To meet NFPA 90A, air filter requirements [Type Class 1] [Type Class 2]; [______]% efficiency, metal framed, [Replaceable media] [Throwaway] [Standard to unit manufacturer]. a. Disposable 2 inch (51 mm) pleated MERV 7 rated. b. Disposable 2 inch (51 mm) pleated MERV 11 rated. 8. Heat Exchanger: Removable for servicing; stainless steel optional for applications where mixed air temperature below 45 degrees F (7 degrees C); E.T.L./C.S.A. design certified for outdoor installation. 9. Gas Heating System: a. Tubular heat exchanger and inshot type gas burners constructed of aluminized steel. b. Direct spark ignition; electronic flame sensor controls; flame rollout switch; limit controls and automatic redundant dual gas valve with staging control and combustion air proving switch on combustion air inducer. Specifier Note: When LPG/propane is required, specify optional kit. 10. 11. c. Able to use LPG/propane [With optional kit]. d. Complete service access provided for controls and wiring. Electric Heating System: a. Available for factory or field installation. b. Heating elements of Nichrome bare wire exposed directly to airstream. Refrigeration System: a. Self−sealing, discharge, suction and liquid line service gauge ports, freeze−stats, expansion valves and full refrigerant charge. b. Copper tubing not to touch sharp metal surfaces. c. Compressor Circuits: Automatic reset, high pressure switch; automatic reset, low pressure switch; liquid line filter−drier. Cooling system capable of operating down to 0 deg. F outdoor temperature as shipped from the factory. d. 12. 13. Capable of operating down to 0 degrees F (−17 degrees C) without installation of additional controls. Supply Air Blower: a. [Constant air volume with adjustable pulleys] [Variable air volume with fixed pulleys and variable frequency drive] [Variable air volume with fixed pulleys and variable frequency drive with bypass]. b. Centrifugal supply air blower with [Permanently lubricated ball bearings and adjustable belt drive] [Sleeve bearings and multi−speed direct drive motor]. c. Blower assembly [Slides out of unit] [Is accessible] for servicing. d. Blower wheel statically and dynamically balanced. Integrated Modular Control (IMC): a. Solid−state control board to operate unit. b. Built−in functions include: blower on/off delay; built−in control parameter defaults; service relay output; dirty filter switch input; dehumidistat input, economizer control; [Gas valve delay between stages]; [ETM compatible]; [DDC compatible]; unit diagnosis; diagnostics code storage; indoor air quality input; low ambient controls; minimum run time; night setback mode; smoke alarm mode; low pressure control; thermostat bounce delay; 3−digit display; degrees F or degrees C display, 2−stage heat/3−stage cool thermostat compatible and warm−up mode; [Electric heat staging]. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 80 GUIDE SPECIFICATIONS 14. 15. 16. Gas Heating Controls: a. Remote thermostat[s] as indicated. b. Built−in [Un] fused disconnect switch. c. Two stages of heating control from [Thermostat] [DDC]. d. Supply fan to turn on [40] seconds after heating demand is received with 8 − 60 second adjustable time delay. e. Supply fan to turn off [120] seconds after heating demand has ended with 80 − 300 second adjustable time delay. f. Adjustable delay time of [30] [Value between 30 − 160] seconds between low and high fire of 2−stage gas valve system. g. Heat off delay of [100] [Value between 30 − 300] seconds after thermostat heating demand has ended. h. To turn off heat and keep supply air fan running if overheat limit occurs. i. Adjustable maximum overheat limit trip count during heating cycle of [3] [Value between 1 − 15], with digital output, limit indicator. j. To report error with each occurrence of overheat limit trip and to identify limit that tripped. Error code stored in nonvolatile memory. k. To shut off gas heat if flame rollout occurs and to report error identifying rollout switch. l. Maximum flame rollout switch trip count of [3] during heating cycle, with digital output, limit indicator. Maximum count limit adjustable from 1 − 6 counts. m. To turn off heat if induced airflow is too low and to report error identifying pressure switch. n. Maximum induced airflow pressure switch trip count of [3] during heating cycle, with digital output, limit indicator. Maximum count limit adjustable from 1 − 6 counts. o. Error reported if gas valve not energized 2 minutes after heating demand; gas valve identified. p. Maximum ignition failure count of [3] with digital output, limit indicator. Maximum count limit adjustable from 1 − 6 counts. q. To shut off gas valve if flame not sensed. Error reported and stored in nonvolatile memory. r. Delay between stages on gas valve. s. To shut off unit if gas valve is energized with no demand for heat. Error reported and stored in nonvolatile memory. Electric Heating Controls: a. Panel board with [______] stage controller. b. Remote thermostat[s] as indicated. c. Built−in [Un] fused disconnect switch. d. Supply Fan: Start before electric elements are energized and continue operating until bonnet temperature reaches minimum setting. Include switch for continuous fan operation. e. Two stages of heating control from [Thermostat] [DDC]. f. Supply fan to turn off [20] seconds after heating demand has ended. Time delay adjustable from 0 − 300 seconds. g. With delay time of [12] seconds between low and high heat stages. Time delay adjustable from 12 − 60 seconds. h. To turn off heat and keep supply air fan running if overheat limit occurs. i. Adjustable maximum overheat limit trip count of [3] during heating cycle with digital output, limit indicator. Maximum count limit adjustable from 1 − 15 counts. j. Error reported and identified if overheat limit tripped. Error code stored in nonvolatile memory. Cooling Controls: a. Provide [Smoke detectors in return] [Smoke detectors in supply]. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 81 GUIDE SPECIFICATIONS Specifier Note: Specify b, c or d below. b. c. [Manual] [Automatic] outside [And return] air dampers for fixed outside air quantity. Remote controlled outside [And return] air dampers with damper operator and means for adjusting outside air quantity. d. Motorized outside, return and [Automatic] [Power exhaust] [Gravity] relief dampers with spring return damper operator and control package to automatically vary outside air quantity. Outside air and exhaust air dampers, normally closed. e. Tight−fitting parallel blade dampers with neoprene or suitable gaskets, synthetic bushings and 1% maximum leakage. f. Damper Operation: 24 V, spring return motor with gear train sealed in oil. g. Mixed Air Controls: [Maintain 55 degrees F (13 degrees C)] [Indicated] mixed air temperature (adjustable). h. Up to 2 stages of cooling from [Thermostat] [External DDC controller] without need for additional controls. i. Up to 3 stages of cooling when used with relay and [3−stage thermostat] [DDC controller]. Specifier Note: Specify article j" when used with Lennox L Connection Network Building Automation System. j. k. l. m. n. o. p. q. r. s. t. u. v. w. x. y. z. Up to 4 stages of cooling. To allow blower on delay of up to 60 seconds after cooling demand is received. Default value of zero. To allow blower off delay of up to 240 seconds after cooling demand has ended. Default value of zero. Minimum compressor on time of [240] seconds on 3−phase units, adjustable between 60 − 510 seconds. Minimum compressor off time of [300] seconds on single−phase units, adjustable from 60 − 510 seconds. Default maximum high pressure switch trip occurrence during cooling or dehumidification cycle of [3]. Trip occurrence limit adjustable from 1 − 8 occurrences. If maximum limit reached, compressor locked out and digital output for service activated. Default maximum low pressure switch trip occurrence during cooling or dehumidification cycle of [3]. Trip occurrence limit adjustable from 1 − 8 occurrences. If maximum limit reached, compressor locked out and digital output for service activated. Low pressure trip read delay of [5] minutes if compressor off time has been less than 4 hours and outdoor temperature is less than 70 degrees F (21 degrees C). Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Low pressure trip read delay of [15] minutes if compressor off time has been 4 hours or greater and outdoor temperature is less than 70 degrees F (21 degrees C). Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Low pressure trip read delay of [2] minutes if compressor off time has been less than 4 hours and outdoor temperature is 70 degrees F (21 degrees C) or greater. Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Low pressure trip read delay of [8] minutes if compressor off time has been 4 hours or greater and outdoor temperature is 70 degrees F (21 degrees C) or greater. Delay adjustable from 0 − 34 minutes. Temperature set point adjustable from 10 degrees F (−12 degrees C) to 100 degrees F (38 degrees C). Compressor off time adjustable from 1 − 6 hours. Each pressure switch trip occurrence (either high or low) to record error in nonvolatile memory and identify compressor circuit. Low outdoor air temperature compressor lockout set point of 0 degrees F (−18 degrees C) for each compressor circuit. Low outdoor temperature limit set point individually adjustable for each compressor circuit from 80 degrees F (27 degrees C) to −30 degrees F (−34 degrees C). Maximum allowable evaporator freeze−stat trip occurrence of [3] during cooling demand with limit adjustable from 1 − 4 occurrences. Control to shut off compressor each time freeze−stat trip occurs and record error code in nonvolatile memory. If maximum limit reached, compressor locked out and digital output for service activated. Condenser Fan Control: 1) On units with multiple condenser fans, [6] second time delay between condenser fan shutoff and restart to prevent reverse rotation of fan. Time delay adjustable between 0 − 16 seconds. 2) On units with 4 condenser fans, first stage low outdoor temperature set point of 55 degrees F (13 degrees C) that reduces airflow through condenser by turning off some fans. Set point adjustable between 60 degrees F (16 degrees C) and 10 degrees F (−12 degrees C). 3) On units with 6 condenser fans, second stage low outdoor temperature set point of 40 degrees F (4 degrees C) to reduce airflow through condenser by turning off all fans. Set point adjustable between 60 degrees F (16 degrees C) and 10 degrees F (−12 degrees C). 4) On units with 6 condenser fans, condenser fan on delay of [2] seconds. Adjustable between 0 − 240 seconds. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 82 GUIDE SPECIFICATIONS Specifier Note: Edit article below to suit project requirements. If substitutions are permitted, edit text below. Add text to refer to Division 1 Project Requirements (Product Substitutions Procedures) Section. PART 2.02 A. PRODUCT SUBSTITUTIONS Substitutions: No substitutions permitted. PART 3 EXECUTION PART 3.01 MANUFACTURER’S INSTRUCTIONS Specifier Note: Article below is an addition to the CSI SectionFormat and a supplement to MANU−SPEC. Revise article below to suit project requirements and specifier’s practice. A. Compliance: Comply with manufacturer’s written data, including product technical bulletins, product catalog installation instructions, product carton installation instructions and manufacturer SPEC−DATA® sheets. PART 3.02 A. EXAMINATION Site Verification of Conditions: Verify substrate conditions, which have been previously installed under other sections, are acceptable for product installation in accordance with manufacturer’s instructions. PART 3.03 INSTALLATION A. Install [Packaged rooftop units] [And] [Commercial packaged, gas/electric and electric/electric heat pumps] in accordance with manufacturer’s instructions, on roof curbs [Provided by manufacturer] [As indicated]. B. Run drain line from cooling coil condensation drain pan to discharge [Over roof drain]. PART 3.04 FIELD QUALITY CONTROL Specifier Note: Use the following Articles only when manufacturer’s field services are desired to verify the quality of the installed components. Establish the number and duration of periodic site visits required by Manufacturer and specify below. Consult Manufacturer for services required. Delete if field services are not required. A. Have manufacturer of products supplied under this Section review Work involved in handling, installation/application, protection and cleaning of its product[s], and submit written reports in acceptable format to verify compliance of Work with Contract. B. Manufacturer’s Field Services: Provide manufacturer’s field services consisting of product use recommendations and periodic site visits for inspection of product installation in accordance with manufacturer’s instructions. C. Schedule site visits to review Work at stages listed: D. 1. After delivery and storage of products, and when preparatory Work on which Work of this Section depends is complete, but before installation begins. 2. [Twice] during progress of Work at [25%] and [60%] complete. 3. Upon completion of Work, after cleaning is carried out. Obtain reports within [3] days of review and submit. L Series Packaged Gas/Electric − 13 to 30 Tons / Page 83 GUIDE SPECIFICATIONS PART 3.05 PERFORMANCE VERIFICATION Specifier Note: Commissioning must ensure performance verification of every part of the unit including, but not necessarily limited to, the following components, as a factory−built and packaged unit: (a) mixing chamber or plenum with outside air and return air dampers; filters; either (i) heating coil or (ii) gas−fired heating unit; DX refrigeration system (generally with air−cooled condenser DX cooling coil with drain pan); humidifier; supply fan with motor and drive; exhaust air dampers; weatherproof curbs [Incorporating vibration isolators]. A. General: 1. Perform rooftop air handling unit verification in accordance with Section 01750 Starting and Adjusting supplemented as follows: 2. Settings: a. Set outside air and return air dampers for minimum outside air. b. Set outside air and return air dampers for percentage of outside air required by design and repeat measurements of fan capacity. 3. Measurements: a. Measure supply fan capacity. b. Measure pressure drop of each component of air handling unit. c. Measure DBT, WBT of SA, RA, EA. d. Measure air cooled condenser discharge DBT. e. Measure flow rates (minimum and maximum) of SA, RA, EA. f. Measure radiated and discharge sound power levels under maximum heating demand and under maximum cooling demand with compressors running. g. Measure DX refrigeration system performance as specified. 4. Simulations: a. Simulate maximum cooling load and measure refrigerant hot gas and suction temperatures and pressures. b. Simulate maximum heating load and: 1) Verify temperature rise across heat exchanger. 2) Perform flue gas analysis. 3) Verify combustion airflow to heat exchanger. 4) Simulate minimum heating load and repeat measurements. 5. Control Strategies: a. Verify operating control strategies, including: 1) Heat exchanger operating and high limit. 2) Early morning warm−up cycle. 3) Freeze protection. 4) cycle operation, temperature of changeover. 5) Alarms. 6) Voltage drop across thermostat wiring. 7) Operation of remote panel, including pilot lights, failure modes. 6. Operation and Adjustment: a. Check for smooth, vibrationless correct rotation of supply fan impeller. b. Adjust impeller speed as necessary and repeat measurement of fan capacity. c. Reduce differences between fan capacity at minimum and maximum outside air less than [5]%. d. Reduce difference between fan capacity at full cooling and fan capacity at full heating to less than [5]%. e. OAD: Verify for proper travel. f. Use smoke test to verify no short−circuiting of EA, relief air to outside air intake. g. Check for smooth, vibrationless, correct rotation of power exhaust impeller. h. Check capacity of heating unit. i. Refer to other sections of these specifications for PV procedures for other components. PART 3.06 COMPLETION AND CLEANUP A. Upon completion and verification of performance of installation, remove surplus materials, excess materials, rubbish, tools and equipment. END OF SECTION L Series Packaged Gas/Electric − 13 to 30 Tons / Page 84 APPLICATION GUIDE CONTROLS IMC M1−7 AFTERMARKET ZONING SYSTEM INTERFACE Introduction Lennox’ seventh generation premium rooftop unit (RTU) controller, the Integrated Modular Controller (IMC) version M1−7, along with a variable frequency drive (VFD) option on certain L Series® and S−Classt RTUs, increases the ability of premium Lennox RTUs to be applied to a variety of zoning systems. The type of zoning system to be used dictates the type of RTU and the requirements for the zoning control system. The following explains each basic system and how the IMC must interface with an aftermarket zoning control system to meet the requirements of each application. Lennox units in single zone and constant volume bypass applications may utilize an aftermarket unit controller as supervisory controller for the RTU. The IMC runs in thermostat mode and is primarily useful for diagnostic purposes, allowing the aftermarket controller to directly monitor and control heat/cool staging, the bypass damper, zone dampers, economizer damper, etc. When the IMC is used in thermostat mode, a maximum of two stage heating and three stage cooling are available. An optional Four Stage Control (FS1) board may be added to allow four stages of heating and cooling control. Supervisory control must be provided by the Lennox IMC to minimize complication and standardize control on Lennox VFD−controlled variable air volume (VAV) RTUs. In this configuration, the IMC controls the VFD based on static pressure in the supply duct. It controls the economizer, and stages compressors based on discharge air temperature. The aftermarket controller simply sends calls for cooling or heating based on setpoint and schedule conditions. The IMC also has many options for controlling single−stage, 50% power exhaust fans; two−stage, 100% Power exhaust fans; or modulating power exhaust fans. NOTE − Please refer to the IMC Manual (M1−7 Version 5.0x) for additional details. Interface Definition With a aftermarket control system interface, the IMC requires four digital inputs to control the rooftop unit: G (blower enable), OCP (occupied), Y1 (enables discharge cooling), and W1 (enables discharge heating). This application minimizes the controls expertise required to create a viable interface. Further, it creates a consistent, standardized approach conducive to support and trouble−shooting on a broad basis without the need for substantial knowledge of the IMC, VFD, bypass, or aftermarket controllers or systems. SG − Packaged Gas / Electric − 40 Ton / Page 85 APPLICATION GUIDE CONTROLS IMC M1−7 AFTERMARKET ZONING SYSTEM INTERFACE Constant Volume Bypass RTU Wiring Summary (Aftermarket Supervisory Control) 24VAC Digital Signals Ventilation Demand G Occupied Demand Aftermarket RTU Controller L Series / S-Class RTU w/M1-6 or M1-7 IMC TB1 OCP Cooling Demand Y1 Heating Demand TB18 W1 Common C Bypass Damper 2-10V , 2V Full Open Supply Static Pres. Sensor Optional Building Static Pres. Switch or Sensor Variable Air Volume RTU Wiring Summary (IMC Supervisory Control) 24VAC Digital Signals Ventilation Demand Aftermarket RTU Controller L Series / S-Class RTU w/ M1-7 IMC TB1 G Occupied Demand OCP Cooling Demand Heating Demand Common Y1 W1 TB18 C Variable Frequency Drive 2-10V , 10V Full Open (or Bypass Damper as Shown Above ) SG − Package Gas / Electric − 40 Ton / Page 86 Supply Static Pres. Sensor Optional Building Static Pres. Switch or Sensor APPLICATION GUIDE CONTROLS IMC M1−7 AFTERMARKET ZONING SYSTEM INTERFACE Sequence of Operation IMC Supervisory Control Operation when IMC blower (G) input is energized When a G signal is present, the IMC controls the VFD or bypass damper to hold a constant supply duct static pressure based on the input from the IMC pressure sensor using a PID control loop. For increased flexibility, the IMC has separate adjustable static pressure setpoints for ventilation, cooling, heating and smoke alarms. These set points reside in the memory of the IMC, have factory default settings, and may be adjusted in the field prior to start up. Operation when IMC occupied (OCP) input is energized When an OCP signal is present the IMC adjusts the fresh air damper to either a fixed minimum position or allows it to modulate based on a CO2 sensor. The CO2 sensor can be wired directly to the IMC, to another controller that can monitor the sensor and pass a signal to the IMC for damper control, or to both the IMC and another device for monitoring through the desired man−machine interface while the IMC maintains damper control. During morning warm−up/cool−down the IMC keeps the fresh air damper closed based on the IMC configuration settings selected. The set points for minimum and maximum damper position setting and CO2 control reside in the memory of the IMC, have factory default settings, and may be adjusted at start up. They cannot be adjusted using the aftermarket controls system. Operation when IMC first stage cooling (Y1) input is energized When a Y1 signal is present the IMC controls up to 4 stages of cooling (depending on RTU size) to maintain a cooling discharge air temperature setpoint. These stages include mechanical cooling, or outdoor air for cooling with an economizer. The discharge air temperature setpoint resides in the IMC, has a factory default setting, and may be adjusted at start up. It cannot be adjusted using the aftermarket controls system. The IMC has advanced discharge−air cooling reset options selected at start up based on return air temperature and/or outside air temperature. Outside air reset saves energy by gradually increasing the discharge air set point as outside air temperature decreases. Return air reset reduces potential for overcooling if the zoning system is misapplied or has an abnormal condition or dominant zone. The reset gradually increases discharge air temperature as return air temperature decreases. Operation when IMC first stage heating (W1) input is energized When a W1 signal is present, the IMC controls up to 4 stages of heating (depending on RTU size) to maintain a heating discharge air temperature. The heating discharge air temperature set point resides in the IMC, has a factory default setting, and may be adjusted at start up. It cannot be adjusted using the aftermarket controls system. The IMC has advanced discharge air heating reset options based on return air temperature and/or outside air temperature. Outside air reset saves energy by gradually decreasing the discharge air set point as outside air temperature increases. Return air reset reduces possibility of overheating if the zoning system is misapplied, has an abnormal condition or dominant zone. The reset gradually decreases discharge air temperature as return air temperature decreases. Power Exhaust Fan Operation The IMC has many power exhaust fan control options that include single−stage, two−stage and modulating control depending on how the unit is equipped. Stage control options can be triggered based on fresh air damper positions, pressure switches, or a pressure analog sensor. Modulating control for units with VFD powered exhaust fans are typically modulated to maintain return or building static pressure, but can be staged. Set points and operation settings for controlling power exhaust fans reside in the IMC, have factory default settings, and may be adjusted at start up. They cannot be adjusted using the aftermarket controls system. SG − Packaged Gas / Electric − 40 Ton / Page 87 Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at 1−800−4−LENNOX