DCG Series
Submittal Data Form
3- to 6-Ton Self-Contained
Packaged Gas / Electric
Job Name
Location
Purchaser
Order No.
Engineer
Unit No.
Model No.
Unit Designation
Performance Data Certified By:
■ Standard Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Patented tubular heat exchanger
High-efficiency scroll compressor
High and low-pressure switches
Copper tube / aluminum fin coils
Contactor with lugs
High-capacity, steel-cased filter drier
24-volt terminal strip
Convertible airflow orientation
Easy to service
Built-in filter rack with standard 2” filters
Bottom utility entry
Complies with California Low NOx emissions standards
Units meet the performance outlined in Table
6.8.1A of ASHRAE Standard 90.1-2010
• AHRI Certified; ETL Listed
■ Cabinet Features
• Heavy-gauge, galvanized-steel cabinet
with UV-resistant powder-paint finish
• Full Perimeter Rail
• Sloped drain pan
• Curb Fit
*Complete warranty details available from your local dealer or at www.daikincomfort.com.
SS-DCG3
www.daikincomfort.com
6/15
Supersedes 7/13
Job Name
Location
Performance Data
Cooling Performance
Tota Capacity
MBH
Sensible Capacity
MBH
Outdoor Design TMP
ºF DB / WB
Air Temp entering
Evaporator Coil
ºF
Power Input Required
kW
(less blower motor)
Heating Performance
Total Heating Capacity
kW
BTU/h
Supply Air Blower Performance
Total Supply Air
CFM
Ext. Static Pressure
IWG
Blower Speed
RPM
Power Output Required
BHP
Motor Ratings
HP
Power Input Required
kW
Electrical Data
Power Supply
Total Unit Amps
Amps
Max Overcurrent Device:
Fuse
2
Breaker
Amps
www.daikincomfort.com
SS-DCG3
Job Name
Location
MOD
3 TON
GAS, HT PUM
4 TON
GAS, HT PUM
5 TON
GAS, HT PUM
6 TON
GAS, HT PUM
Dimensions
CONDENSATE
DRAIN
BOTTOM EXIT
19.470
5.104
12.000
SUPPLY AIR DUCT
17.000
48.312
23.442
20.905
11.000
6.192
5.558
25.000
RETURN AIR DUCT
74.061
BASE PAN VIEW
(VIEWED FROM TOP)
CONDENSATE
DRAIN
BOTTOM EXIT
MODEL TONNAGES
3 TON COMMERCIAL
GAS, HT PUMP, AIR CONDITIONER
4 TON COMMERCIAL
GAS, HT PUMP, AIR CONDITIONER
5 TON COMMERCIAL
GAS, HT PUMP, AIR CONDITIONER
6 TON COMMERCIAL
GAS, HT PUMP, AIR CONDITIONER
"A"
"B"
"C"
38.840
16.555
26.055
38.840
16.555
26.055
38.840
16.555
26.055
42.840
20.555
30.055
7.984
LINE WIRE
ENTRANCE
"A"
"C"
"B"
8.555
TSTAT WIRE
ENTRANCE
5.872
10.372
LEFT END VIEW
ETURN AIR DUCT
74.061
BASE PAN VIEW
SS-DCG3
www.daikincomfort.com
3
Job Name
Location
Accessories List (Detailed specifications begin on the following page.)
Item #
Description
Fits
Model Sizes
FieldInstalled
14CURB3672
14" Roof Curb
3-6 tons
√
D25FD3672
25% Manual Fresh Air Damper
3-6 tons
√
D25MFD3672
25% Motorized Fresh Air Damper
3-6 tons
√
DDNBBS3672
Burglar Bar Sleeves with Supply & Return
3-6 tons
√
CDK36
Concentric Duct Kit
3 tons
√
CDK4872
Concentric Duct Kit
4-6 tons
√
HAILGD03D
Condenser Coil Hail Guard
3-5 tons
√
HAILGD04D
Condenser Coil Hail Guard
6 tons
√
Convenience Outlet: Non Powered
All Models
√
Convenience Outlet: Powered
All Models
√
Disconnect Switch
All Models
√
DDNECNJ3672
Downflow Economizer
3-6 tons
√
DDNECNJ3672NR
Downflow Economizer w/o Barometric Relief
3-6 Tons
√
DDNSQRD3616
Downflow Square-to-Round Adapter (16" Round)
3 tons
√
DDNSQRD487218
Downflow Square-to-Round Adapter (18" Round)
4-6 tons
√
HAKT36300
High-Altitude Kit
All Models
√
HSKT036B
High-Static Kit (230/460v)
3 tons
√
HSKT036B-7
High-Static Kit (575v)
3 tons
√
HSKT048B
High-Static Kit (230/460v)
4 tons
√
HSKT048B-7
High-Static Kit (575v)
4 tons
√
HSKT060B
High-Static Kit (230/460v)
5 tons
√
HSKT060B-7
High-Static Kit (575v)
5 tons
√
HSKT072B
High-Static Kit (230/460v)
6 tons
√
HSKT072B-7
High-Static Kit (575v)
DHZECNJ3672
Horizontal Economizer
6 tons
√
3-6 tons
√
GHRC-1
Hurricane Restraint Clips
All Models
√
DBRD3672
Barometric Relief Damper
3-6 tons
√
LAKT01
Low-Ambient Kit
3-6 tons
√
LPM-06
LP Conversion Kit
3-6 tons
√
LPT-00A
LP Conversion Kit (DCG036045 only)
3 tons
√
DPE36722
Power Exhaust (208/230 Volt)
3-6 tons
√
DPE36724
Power Exhaust (460 Volt)
3-6 tons
√
DPE36727
Power Exhaust (575v)
3-6 tons
√
IP3672
Roof Curb Insulated Panels
3-6 Tons
√
Smoke Detector
4
FactoryInstalled
All Models
www.daikincomfort.com
✔
√
√
√
SS-DCG3
Job Name
Location
Roof Curb — #D14CURB3672
3-D View
Top View
Insulated
Panels
70¾
40¼
14 x 20
Supply Opening
14
31⅝ x 14
Return Opening
¾
15/6
14
1⅜
Specifications
•
•
•
•
•
18-Gauge Construction
1 x 4 Wood Nailer attached to top of the curb
Shipped knocked down with all hardware
Gasket included
Bed-Rail style corners
Note: outside duct dimension should be ½” less than opening dimensions above.
No Curb Adapter Required when Replacing Carrier & Bryant Models
No curb adapter is required when replacing an existing Carrier or Bryant RTU with a Goodman RTU
in these situations; the footprints and locations of the return and supply duct work match.
SS-DCG3
New Unit
Existing Carrier
Existing Bryant
3 to 6 Tons
48/50 TJ, LJ, DJ, QJ
48/50 TM, HJ
004 - 007
580C-D, 558C-D, 548C-D
580F, 558F, 581B
036 - 072
www.daikincomfort.com
5
Job Name
Location
Manual Fresh Air Damper — #D25FD3672
Motorized Fresh Air Damper — #D25MFD3672
Specifications
Manual Damper
• Provides up to 25% fresh air
• Locking selection knob
provides constant opening
• Painted to match the unit
• Fits all 3- to 5-ton package
units in all fuels
Motorized Damper
• 24 VAC Damper motor
with spring return
• Fully assembled and factory wired
• Painted to match the unit
• Fits all 3- to 5-ton package
units in all fuels
Hail Guard — #HailGD0*
Specifications
• Condenser coil protection
• Prevents hail damage
• Easy to remove and clean
• Powder paint finish
6
www.daikincomfort.com
SS-DCG3
Job Name
Location
Downflow Economizer — #DDNECNJ3672
Specifications
• Fully modulating
• Up to 100% fresh air
• Integral barometric relief
• Hoods painted to match unit
• Honeywell economizer control
• Single adjustable enthalpy control
convertible to dual enthalpy
• Adjustable minimum fresh air
• Factory wired
• Fits all 3- to 5-ton models
SS-DCG3
www.daikincomfort.com
7
Job Name
Location
Horizontal Economizer — #DHZECNJ3672
Specifications
• Fully modulating
• Up to 100% fresh air
• Honeywell economizer control
• Single adjustable enthalpy control
convertible to dual enthalpy
• Adjustable minimum fresh air
• Factory wired
• Fits all 3- to 5-ton models
8
www.daikincomfort.com
SS-DCG3
Job Name
Location
Barometric Relief Damper — #DBRD3672
Hurricane / Seismic Clip — DHRC-1
Specifications
• 14-gauge construction
• Location and quantity of clips dictated by unit need
• Clips are fastened to the unit and curb using sheet-metal screws
• Seismic angle is fastened with approved fastener
SS-DCG3
www.daikincomfort.com
9
Job Name
Location
Concentric Duct Kit — #CDK36 / #CDK4872
Commercial
T-Bar Ceiling
Light Commercial
T-Bar Ceiling
Specifications
• All-aluminum diffuser with
aluminum return air egg crate
• Built-in anti-sweat gasket
• Molded fiberglass transition (through five tons)
• Built-in hanging supports
• Diffuser box constructed of
fiberglass duct board (through
7½ tons) or sheet metal
Hanging Support
from the Diffuser
Turing Vane to
Ensure Proper Airflow
Aluminum
Egg Crate
Molded
Fiberglass
Transition
10
www.daikincomfort.com
SS-DCG3
Job Name
Location
3-Ton Square-to-Round — #DDNSQRD3616
4- to 6-ton Square-to-Round — #DDNSQRD487218
SS-DCG3
www.daikincomfort.com
11
Job Name
Location
Notes
Our continuing commitment to quality products may mean a change in specifications without notice.
© 2015
• Houston, Texas • Printed in the USA.
12
www.daikincomfort.com
SS-DCG3
Download