DCG Series Submittal Data Form 3- to 6-Ton Self-Contained Packaged Gas / Electric Job Name Location Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: ■ Standard Features • • • • • • • • • • • • • Patented tubular heat exchanger High-efficiency scroll compressor High and low-pressure switches Copper tube / aluminum fin coils Contactor with lugs High-capacity, steel-cased filter drier 24-volt terminal strip Convertible airflow orientation Easy to service Built-in filter rack with standard 2” filters Bottom utility entry Complies with California Low NOx emissions standards Units meet the performance outlined in Table 6.8.1A of ASHRAE Standard 90.1-2010 • AHRI Certified; ETL Listed ■ Cabinet Features • Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish • Full Perimeter Rail • Sloped drain pan • Curb Fit *Complete warranty details available from your local dealer or at www.daikincomfort.com. SS-DCG3 www.daikincomfort.com 6/15 Supersedes 7/13 Job Name Location Performance Data Cooling Performance Tota Capacity MBH Sensible Capacity MBH Outdoor Design TMP ºF DB / WB Air Temp entering Evaporator Coil ºF Power Input Required kW (less blower motor) Heating Performance Total Heating Capacity kW BTU/h Supply Air Blower Performance Total Supply Air CFM Ext. Static Pressure IWG Blower Speed RPM Power Output Required BHP Motor Ratings HP Power Input Required kW Electrical Data Power Supply Total Unit Amps Amps Max Overcurrent Device: Fuse 2 Breaker Amps www.daikincomfort.com SS-DCG3 Job Name Location MOD 3 TON GAS, HT PUM 4 TON GAS, HT PUM 5 TON GAS, HT PUM 6 TON GAS, HT PUM Dimensions CONDENSATE DRAIN BOTTOM EXIT 19.470 5.104 12.000 SUPPLY AIR DUCT 17.000 48.312 23.442 20.905 11.000 6.192 5.558 25.000 RETURN AIR DUCT 74.061 BASE PAN VIEW (VIEWED FROM TOP) CONDENSATE DRAIN BOTTOM EXIT MODEL TONNAGES 3 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 4 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 5 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER 6 TON COMMERCIAL GAS, HT PUMP, AIR CONDITIONER "A" "B" "C" 38.840 16.555 26.055 38.840 16.555 26.055 38.840 16.555 26.055 42.840 20.555 30.055 7.984 LINE WIRE ENTRANCE "A" "C" "B" 8.555 TSTAT WIRE ENTRANCE 5.872 10.372 LEFT END VIEW ETURN AIR DUCT 74.061 BASE PAN VIEW SS-DCG3 www.daikincomfort.com 3 Job Name Location Accessories List (Detailed specifications begin on the following page.) Item # Description Fits Model Sizes FieldInstalled 14CURB3672 14" Roof Curb 3-6 tons √ D25FD3672 25% Manual Fresh Air Damper 3-6 tons √ D25MFD3672 25% Motorized Fresh Air Damper 3-6 tons √ DDNBBS3672 Burglar Bar Sleeves with Supply & Return 3-6 tons √ CDK36 Concentric Duct Kit 3 tons √ CDK4872 Concentric Duct Kit 4-6 tons √ HAILGD03D Condenser Coil Hail Guard 3-5 tons √ HAILGD04D Condenser Coil Hail Guard 6 tons √ Convenience Outlet: Non Powered All Models √ Convenience Outlet: Powered All Models √ Disconnect Switch All Models √ DDNECNJ3672 Downflow Economizer 3-6 tons √ DDNECNJ3672NR Downflow Economizer w/o Barometric Relief 3-6 Tons √ DDNSQRD3616 Downflow Square-to-Round Adapter (16" Round) 3 tons √ DDNSQRD487218 Downflow Square-to-Round Adapter (18" Round) 4-6 tons √ HAKT36300 High-Altitude Kit All Models √ HSKT036B High-Static Kit (230/460v) 3 tons √ HSKT036B-7 High-Static Kit (575v) 3 tons √ HSKT048B High-Static Kit (230/460v) 4 tons √ HSKT048B-7 High-Static Kit (575v) 4 tons √ HSKT060B High-Static Kit (230/460v) 5 tons √ HSKT060B-7 High-Static Kit (575v) 5 tons √ HSKT072B High-Static Kit (230/460v) 6 tons √ HSKT072B-7 High-Static Kit (575v) DHZECNJ3672 Horizontal Economizer 6 tons √ 3-6 tons √ GHRC-1 Hurricane Restraint Clips All Models √ DBRD3672 Barometric Relief Damper 3-6 tons √ LAKT01 Low-Ambient Kit 3-6 tons √ LPM-06 LP Conversion Kit 3-6 tons √ LPT-00A LP Conversion Kit (DCG036045 only) 3 tons √ DPE36722 Power Exhaust (208/230 Volt) 3-6 tons √ DPE36724 Power Exhaust (460 Volt) 3-6 tons √ DPE36727 Power Exhaust (575v) 3-6 tons √ IP3672 Roof Curb Insulated Panels 3-6 Tons √ Smoke Detector 4 FactoryInstalled All Models www.daikincomfort.com ✔ √ √ √ SS-DCG3 Job Name Location Roof Curb — #D14CURB3672 3-D View Top View Insulated Panels 70¾ 40¼ 14 x 20 Supply Opening 14 31⅝ x 14 Return Opening ¾ 15/6 14 1⅜ Specifications • • • • • 18-Gauge Construction 1 x 4 Wood Nailer attached to top of the curb Shipped knocked down with all hardware Gasket included Bed-Rail style corners Note: outside duct dimension should be ½” less than opening dimensions above. No Curb Adapter Required when Replacing Carrier & Bryant Models No curb adapter is required when replacing an existing Carrier or Bryant RTU with a Goodman RTU in these situations; the footprints and locations of the return and supply duct work match. SS-DCG3 New Unit Existing Carrier Existing Bryant 3 to 6 Tons 48/50 TJ, LJ, DJ, QJ 48/50 TM, HJ 004 - 007 580C-D, 558C-D, 548C-D 580F, 558F, 581B 036 - 072 www.daikincomfort.com 5 Job Name Location Manual Fresh Air Damper — #D25FD3672 Motorized Fresh Air Damper — #D25MFD3672 Specifications Manual Damper • Provides up to 25% fresh air • Locking selection knob provides constant opening • Painted to match the unit • Fits all 3- to 5-ton package units in all fuels Motorized Damper • 24 VAC Damper motor with spring return • Fully assembled and factory wired • Painted to match the unit • Fits all 3- to 5-ton package units in all fuels Hail Guard — #HailGD0* Specifications • Condenser coil protection • Prevents hail damage • Easy to remove and clean • Powder paint finish 6 www.daikincomfort.com SS-DCG3 Job Name Location Downflow Economizer — #DDNECNJ3672 Specifications • Fully modulating • Up to 100% fresh air • Integral barometric relief • Hoods painted to match unit • Honeywell economizer control • Single adjustable enthalpy control convertible to dual enthalpy • Adjustable minimum fresh air • Factory wired • Fits all 3- to 5-ton models SS-DCG3 www.daikincomfort.com 7 Job Name Location Horizontal Economizer — #DHZECNJ3672 Specifications • Fully modulating • Up to 100% fresh air • Honeywell economizer control • Single adjustable enthalpy control convertible to dual enthalpy • Adjustable minimum fresh air • Factory wired • Fits all 3- to 5-ton models 8 www.daikincomfort.com SS-DCG3 Job Name Location Barometric Relief Damper — #DBRD3672 Hurricane / Seismic Clip — DHRC-1 Specifications • 14-gauge construction • Location and quantity of clips dictated by unit need • Clips are fastened to the unit and curb using sheet-metal screws • Seismic angle is fastened with approved fastener SS-DCG3 www.daikincomfort.com 9 Job Name Location Concentric Duct Kit — #CDK36 / #CDK4872 Commercial T-Bar Ceiling Light Commercial T-Bar Ceiling Specifications • All-aluminum diffuser with aluminum return air egg crate • Built-in anti-sweat gasket • Molded fiberglass transition (through five tons) • Built-in hanging supports • Diffuser box constructed of fiberglass duct board (through 7½ tons) or sheet metal Hanging Support from the Diffuser Turing Vane to Ensure Proper Airflow Aluminum Egg Crate Molded Fiberglass Transition 10 www.daikincomfort.com SS-DCG3 Job Name Location 3-Ton Square-to-Round — #DDNSQRD3616 4- to 6-ton Square-to-Round — #DDNSQRD487218 SS-DCG3 www.daikincomfort.com 11 Job Name Location Notes Our continuing commitment to quality products may mean a change in specifications without notice. © 2015 • Houston, Texas • Printed in the USA. 12 www.daikincomfort.com SS-DCG3