VARIABLE FREQUENCY DRIVE |Pump |Metal Processing Machinery |Conveyor Belt Machinery |Textile Machinery |Other Industries VARIABLE FREQUENCY DRIVE RM6E .Pump .Metal Processing Machinery .Conveyor Belt Machinery .Textile Machinery .Other Industries RHYMEBUS CORPORATION No. 17, Taichung Industrial park 33rd Road, Taichung City, Taiwan 40768 TEL: +886-4-23595237 FAX: +886-4-23595235 Website: www.rhymebus.com.tw E-mail: inverter@mail.rhymebus.com.tw 2011.03.31/ XB200078 Copyright 2011 RHYMEBUS. All rights reserved. Specifications subject to change without notice. www.rhymebus.com.tw www.rhymebus.com.tw VARIABLE FREQUENCY DRIVE GREEN TECH, GREEN LIFE www.rhymebus.com.tw FEATURES & THE DESCRIPTION OF NOMENCLATURE Suitable for the constant/ variable torque load- mixer, conveyor, fan, pump, etc. |Pump|Metal Processing Machinery |Conveyor Belt Machinery |Textile Machinery|Other Industries The drive can control and start the synchronous motor. FEATURES & THE DESCRIPTION OF NOMENCLATURE 02 SPECIFICATIONS 03 GENERAL SPECIFICATIONS 04 TERMINALS DEFINITION 06 Adjustable responding time of the digital input signal. One set of programmable relays. Multifunctional special key (SPEC). External digital keypad (KP-601) for remote control. Data duplicating and memory functions. Energy saving option for light duty load. Temperature and fan control. RS-485 Modbus RTU with the communication function (optional). PLC automatic operation, PID control, Build-in DBU. The description of nomenclature RM6E 2 001 B 1 Input voltage phase 1: 1PH 3: 3PH Brake type B: Build-in braking transistor Horse Power Code Horse Power 0P5 0.5 (HP) 001 1 1P5 1.5 002 2 003 3 005 5 Horse power (please refer to the chart on the right ) VARIABLE FREQUENCY DRIVE 01 Input voltage 1: AC100V~120V 2: AC200V~240V 4: AC380V~480V Type name 02 VARIABLE FREQUENCY DRIVE SPECIFICATIONS GREEN TECH, GREEN LIFE A. 1ψ100V Series GENERAL SPECIFICATIONS A. Control and operational characteristics Model No.-RM6E 10P5 1001 Maximum Applicable Motor (HP/KW) 0.5/0.4 1/0.75 Rated Output Capacity (KVA) 1.0 1.5 Rated Output Current (A) 2.5 4.0 3ψ, 200-240V Rated Output Voltage (V) 1ψ, 100-120V, 50/60Hz Power Source (ψ, V, Hz) Input Current (A) 10.2 18.9 Permissible Voltage Fluctuation Natural cooling Fan cooling B. 1ψ200V Series Model No.-RM6E 20P5 2001 2002 2003* Maximum Applicable Motor (HP/KW) 0.5/0.4 1/0.75 2/1.5 3/2.2 1.1 1.6 2.3 4.0 3 4.2 7.5 10.5 Rated Output Capacity (KVA) Rated Output Current (A) Control characteristics ±5% Cooling Method Input Current (A) 7.9 12.5 2002 2003* 2005* Maximum Applicable Motor (HP/KW) 0.5/0.4 1/0.75 2/1.5 3/2.2 5/3.7 1.1 1.6 3 4.2 6.5 3 4.2 8 11 17 3ψ, 200-240V 400.00Hz 3ψ, 200-240V, 50/60Hz Power Source (ψ,V, Hz) 5.4 6.8 12.8 Permissible Voltage Fluctuation 14 18 176V-264V Permissible Frequency Fluctuation ±5% Natural cooling Fan cooling Natural cooling Fan cooling D. 3ψ400V Series 4001* 4002* 4003* 4005* 1/0.75 2/1.5 3/2.2 5/3.7 Rated Output Capacity (KVA) 1.9 3.0 4.6 6.9 Rated Output Current (A) 2.5 4 6 9 0.015~19200000 sec (Acceleration from 0 to 60Hz, 222 days) Acc/constant speed stall prevention (Stall prevention current 30~200%) and Decelerating stall prevention Slip compensation, automatic torque compensation, automatic constant pressure overload detection level, DC brake, dynamic brake duty control, PLC control, timer management, setting duplication Frequency setting signal 8 12 Fan cooling Fan cooling Analog signal: (DC 0-10V/2-10V)/0~100% or (DC 0-20mA/4-20mA)/0~100% Digital signal: Jog speed, 16-speed control can be selected RS-485 Modbus communication Keypad (include KP-601controller):RUN / STOP Operation setting signal Digital signal: FWD/REV control, 3-line sustaining circuit RS-485 Modbus communication 4sets programmable input terminals: X1-X4 Multi-function inputs Reaction time (1~255, Unit: 1ms) Please refer to function settings 1set analog input terminal: AI(0-10V/2-10V or 0-20mA/4-20mA) Analog inputs Analog filter (0~255, Unit: 5ms), analog frequency dead zone, variable gain and bias Please refer to function settings Multi-function outputs 1set programmable output terminals:Ta/Tc Please refer to function settings 1set analog output:FM(0-10V/2-10V or 0-20mA/4-20mA) Analog outputs variable gain and bias Please refer to function settings 400.00Hz Maximum Output Frequency (Hz) 3ψ, 380-480V, 50/60Hz Power Source (ψ,V, Hz) 3.5 5 Permissible Voltage Fluctuation 332V-528V Permissible Frequency Fluctuation ±5% Natural cooling Fan cooling *:Under development 03 0 second (coast to stop), 0.0-3200.0 seconds (acc/dec independent setting ) 3ψ, 380-480V Rated Output Voltage (V) Cooling Method Stall prevention Fan cooling *:Under development Input Current (A) Acc. / dec. times Keypad (include KP-601controller):▲ ▼ Operational Characteristics 2001 Maximum Applicable Motor (HP/KW) V/F curve: V independent adjustment (Independent V acc/dec adjustment) Fan cooling 20P5 Maximum Output Frequency (Hz) The power of 1.5, 1.7, 2 curve frequency, upper and lower frequency limits, 16 preset speeds, Model No.-RM6E Rated Output Voltage (V) About 20% (with braking resistor, braking torque can reach about 100%) acceleration/deceleration switching, S curve acceleration/deceleration, fan control Fan cooling Natural cooling Holding power 0~150% rated current V/F curve (2 turning points) V/F curve ±5% Natural cooling Start/stop holding time 0~60.0 secs, stop holding frequency 0.1~60Hz function, PID control, RS-485 Modbus communication, jump frequency, holding C. 3ψ200V Series Model No.-RM6E Braking torque * *:Under development Cooling Method 150% drive rated current for 1 minute 176V-264V Permissible Frequency Fluctuation Input Current (A) 0.01Hz Overload protection compensation, restart after instantaneous power failure/flying start, speed searching, 18.3 Permissible Voltage Fluctuation Analog input:0.06Hz/60Hz Resolution of output frequency Other functions 1ψ, 200-240V, 50/60Hz Power Source (ψ,V, Hz) Keypad:0.01Hz(0.01~99.99Hz/100.0~400.0Hz) output adjustment, automatic energy saving operation, automatic voltage 400.00Hz Maximum Output Frequency (Hz) Rated Output Current (A) 0.1-400.0Hz 3ψ, 200-240V Rated Output Voltage (V) Rated Output Capacity (KVA) Sinusoidal PWM method (V/F control ), switching frequency: 0.8~16kHz Range of frequency setting DC brake functions 88V-132V Permissible Frequency Fluctuation Control method Resolution of frequency setting 400.00Hz Maximum Output Frequency (Hz) Cooling Method www.rhymebus.com.tw VARIABLE FREQUENCY DRIVE 04 www.rhymebus.com.tw VARIABLE FREQUENCY DRIVE GREEN TECH, GREEN LIFE B. Display, protections, environment TERMINALS DEFINITION A. Terminals of main circuit Terminals IGBT module error (Fot) - note1, grounding fault protection (GF), drive over-current protection Power source overload protection setting (OLO), overload voltage protection (OE), high voltage (Hv), low Warning/Fault protection voltage (LE and LE1), drive overheat (OH, Ht), motor overheat (OH1, OH2), PID feedback signal error (noFb), FWD/REV simultaneous operation (dtF), external fault (EF), output interrupt (bb), free run (Fr), keypad disconnected during drive setting duplication (PAdF), drive inter-duplication with different software versions (wrF), keypad disconnected (Err_00、Err_01), RS-485 Modbus communication overtime (Cot) Environment Display Diagnostics Main Circuit Protections (OC with short circuit protection), motor overload (OL), drive overload (OL1), current limit (OL2), AD converter failure (AdEr), Drive memory error (EEr1, EEr2),EEPROM error (EEr) Motor Power and braking Symbol Function Name R,S,T Descriptions Three phase power source Input AC voltage (L1,L2,L3) U,V,W (T1,T2,T3) P(+),N(-) PR Single phase power source: R,S(L1,L2) terminal Drive output voltage Three phase variable frequency and voltage output to motor Dynamic braking terminal Connect to the dynamic brake unit External braking resistor P and PR terminal connect to an external braking resistor (optional) Ground the inverter in compliance with the national or local electric Grounding Grounding code 4digits 7-steps display, 8 status indicator LED, 8 keys, 1analog pot Build-in control panel 8 types of displays: output frequency, setting frequency, output voltage, DC voltage, output current, 3types of displays (programmable) External display IP level Atmosphere B. Terminals of control circuit External connected to KP-601controller IP20 Terminals The installation space can not have corrosiveness, conductive gas and liquid. It can not have Symbol X1 dust either. Surrounding temperature Storage temperature -10℃~+40℃(no dew and frost) Relative humidity Under 90%RH (no dew) (note 1) Vibration Under 5.9m/sec2(0.6G) X3 Altitude Altitude 1000 meter (below 3280 feet) (note 1) X2 -20℃~+60℃ (note 1) Input terminals ψ5 (note 1) Control Circuit COM (note 2) GND (Factory setting: FWD command) Multi-function input X2 and COM is short-circuit, the function depends on settings. terminal 2 (Factory setting: REV command) Multi-function input X3 and COM is short-circuit, the function depends on settings. terminal 3 (Factory setting: Jog command) Multi-function input X4 and COM is short-circuit, the function depends on settings. terminal 4 (Factory setting: Reset command) Common of input terminal Common of input terminal signals command) Analog input terminals DC 0~10V/2~10V(20KΩ) Power terminal for control signal DC+12V input, maximum 20mA. Grounding terminal for Grounding terminal (COM and GND use the same terminal ) control signal The function depends on settings. (Factory setting: output frequency) (note 3) Analog output terminals DC 0~10V/2~10V(Max 1mA) DC 0~20mA/4~20mA(Max 500Ω) Output terminals R 2.5 The function depends on settings. Ta 5.0 X1 and COM is short-circuit, the function depends on settings. terminal 1 DC 0~20mA/4~20mA(250Ω) 12V FM Overall dimension (Unit: mm) Descriptions Multi-function input The function depends on settings. (Factory setting: frequency AI Power source 158.0 146.0 X4 Name (Factory setting: error signal detection) Multi-function terminals Relay type (Capacity AC250V, 0.2A Max, COSθ=0.3) Common terminal for Ta Tc 76.0 76.0 2-M4 88.0 Note 1:SINK/SOURCE choice depends on JP2 (Factory setting: SINK) Note 2:V/I choice depends on JP1 (Factory setting: V) Note 3:FMV/FMI choice depends on JP3 (Factory setting: FMV) C. Communication connector (RJ-45) 146.0 140.1 Terminal Type RS-485 Modbus communication /KP communication Terminal Location Communication transfer port (DX+) RS-485 Differential inputs (note 1) 2 Communication transfer port (DX-) RS-485 Modbus communication only uses location 1 and 2 3 KP power port (+16V) Specific for KP connection 4 KP automatic detection port Specific for KP connection Reserved Reserved KP power common port (0V) Specific for KP connection 5 6 8 05 Descriptions 1 7 Note 1:Only 100/200V under 2hp has Fot protection Terminal Name Note 1: Terminal resistance 100Ω choice depends on DSW1 (Factory setting: ON) 06