SOLA/ HEVI-DUTY General Purpose Transformers Selection Tables: Single Phase Listed Group IA - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz (Encapsulated) . Certified Height (inch) Width (inch) Depth (inch) Ship Weight Approx. (Ibs) Design Style Elec Conn Primary Amps Secondary Amps HS1B50 7 4 3 3 2 1 .208/.104 .416/.208 .075 HS1B75 7 4 3 3 2 1 .31 21. 156 .625/.312 .100 HS1B100 7 4 3 4 2 1 .417/.208 .833/.417 .150 HS1B150 7.5 5 4 5 2 1 .625/.313 1.25/.625 .250 HS1B250 7.5 5 4 8 2 1 1.04/.512 2.08/1.04 .500 HS1F500B 10 6 5 22 3 1 2.08/1.04 4.16/2.08 .750 HS1F750B 10 6 5 23 3 1 3.13/1.56 6.25/3.13 Catalog Number KVA .050 HS1F1BS 10 6 5 28 3 2 4.17/2.08 8.33/4.17 HS1F1.5AS 13 10 7 39 4 2 6.25/3.13 12.5/6.25 2 HS1F2AS 13 10 7 47 4 2 8.33/4.17 16.7/8.33 3 HS5F3AS 13 10 7 55 4 3 12.5/6.25 25.0/12.5 5 HS5F5AS 17 14 9 104 4 3 20.8/10.4 41 .6/20.8 1 1.5 7.5 HS5F7.5AS 17 14 9 135 4 4 31.3/15.6 62.5/31.3 10 HS5F10AS 28 14 9 156 4 4 41 .7/20.8 83.3741. 7 Ship Weight Approx. (Ibs) Design Style Elec Conn Primary Amps Note: See Section 7 for Higher KVA encapsulated units. Group IB - 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz KVA Catalog Number NEMA3R Weather Shield Height (inch) Width (inch) Depth (inch) •Secondary Amps 15 S5H15S WS-01 23 14 16 160 1 5 62.5/31.3 125/62.5 25 S5H25S WS-15 28 16 16 230 1 5 104/52.1 208/104 37.5 S5H37S WS-17 31 18 18 310 1 5 156/78 313/156 50 S5H50S WS-17 31 18 18 380 1 5 208/104 416/208 75 S5H75S WS-09 44 23 21 555 1 5 313/156 625/313 100 S5H100S WS-09 44 23 21 650 1 5 41 7/208 833/417 167 S5H167S WS-16 46 26 24 905 1 5 695/348 1 392/695 250* S5H250S N/A 65 36 35 1580 1 5 1042/521 2083/1042 Design Style Elec Conn Primary Amps* Secondary Amps * Not UL or CSA Approved Group II - 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz NEMA3R Weather Shield Height (inch) HS12F1BS N/A HS12F1.5AS N/A 2 HS12F2AS 3 5 Width (inch) Depth (inch) Ship Weight Approx. (Ibs) 10 6 5 29 3 9 3.6 8.33/4.17 13 10 7 40 4 10 5.4 12.5/6.25 N/A 13 10 7 60 4 10 7.2 16.7/8.33 HS12F3AS N/A 13 10 7 66 4 10 10.8 25.0/12.5 HS12F5AS N/A 17 14 9 104 4 10 18.0 41 .6/20.8 7.5 HS12F7.5AS N/A 17 14 9 135 4 10 27.1 62.5/31.3 10 HS12F10AS N/A 17 14 9 156 4 10 36.1 83.3/41.7 KVA 1 1.5 Catalog Number 15 S12H15S WS-01 23 14 16 200 1 11 54.2 125/62.5 25 S12H25S WS-15 28 16 16 250 1 11 90.3 208/104 * Amperage calculated at 277 Volts on primary. 72 Fax-on-Demand #: (877) 888-9329, Document #: 8332 Contact Technical Services at (800) 377-4384 with any questions. General Purpose Transformers • Copper lead wire terminations. Single Phase: .05-.250 KVA Features • Units 1 -10 KVA are encapsulated with electrical grade silica sand and epoxy for rugged applications. • Nonmetallic nameplates list all rating data. Wiring diagram strategically located on inside of wiring compartment cover. • UL-3R enclosure for indoor or outdoor service. • Fast, easy installation. Mounting holes built into the enclosure. • Low temperature rise, UL class 105°C insulation system, 55°C temperature rise under full load. Can be banked for three phase service. • Nonmetallic nameplates list all rating data. Wiring diagram strategically located on inside of wiring (Ml Listed compartment cover. Single Phase: 15-250 KVA Three Phase: 15-500 KVA Features Certified • Conduit knockouts for side entry into roomy wiring compartment. • Copper lead wire terminations. • Quiet operation. Single Phase: .500-10 KVA Three Phase: 3-9 KVA Features • UL-3R enclosures for indoor or outdoor service. • Fast, easy installation. • Electrostatically shielded for quality power on sizes 1 KVA and larger. • Efficient operation. UL class 180°C insulation system, 115°C temperature rise under full load. Can be banked for three phase service. • Conduit knockouts for side entry into roomy wiring compartment. • UL class 220°C insulation system, 150°C temperature rise under full load. • Electrostatically shielded for quality power. • Front connected terminal board and spacious wiring compartment. • UL-3R outdoor enclosures when used with optional weather shields (order separately). • Panel enclosure design reduces labor time. Remove only two bolts for entry. Wiring diagram on inside front cover. • Core and coil completely isolated from enclosure by means of vibration dampening pads to provide quiet operation. Accessories and Design Styles • Wall mounting brackets - for ventilated design units, single and three phase, 15 to 75 KVA. The catalog number for all wall brackets is WB-1C. • Totally enclosed non-ventilated designs are available for sizes 15 KVA and larger. • Core and coil designs are available for sizes 15 KVA and larger. • Surge Suppression Devices (page 5) provide additional protection and longevity to any electronic equipment. • Weather Shields. Design Styles w W H H CD Style 1 70 Style 2 Fax-on-Demand #: (877) 888-9329, Document #: 8331 Contact Technical Services at (800) 377-4384 with any questions. SOLA/ HEVI-DUTY General Purpose Transformers Construction Features • Free Shielding • Easy Installation UL-3R Enclosures Fast Delivery • 10 Years+2 Warranty High impact powder paint finish UL-3R Enclosure (with optional weather srueld) Shielded for quality power Remove two bolts for interior access, front or rear. Easily accessed tap connections. Coils Vibration and sound dampening pad. Fiberglass terminal board relieves cable stress. Enclosure bottom designed for ventilation and rodent protection. Large, easy to read wiring diagram inside front cover. Flexible ground strap (included but not shown). Fax-on-Demand #: (877) 888-9329, Document #: 8331 Contact Technical Services at (800) 377-4384 with any questions. 71 General Purpose Transformers Electrical Connections (Single Phase) H1 240 X 480 Volt Primary 120/240 Volt Secondary Taps: 2, 21/2% FCAN & FCBN 240 X 480 Volt Primary 120/240 Volt Secondary Taps: None 240 X 480 Volt Primary 120/240 Volt Secondary Taps: None 1 H3 H1 H2 H3 H4 H5 L>^A_A_X_A_X>J Connect Lines to Primary Voltage Interconnect H1 to H3 Connect Lines to H1 to H3 H2 to H4 H2 to H4 Secondary Voltage Connect Lines to Secondary Vottage Interconnect X1 to X3 X1 & X4 X2 to X4 240 X 480 Volt Primary, 120/240 Volt Secondary Taps: 2, 21/2% FCAN; 4, 21/2% FCBN H1 H2H3H4H5 A H1 H6H7H8H9 H10 240 X 480 Volt Primary, 1 20/240 Volt Secondary Taps: 2, 21/2% FCAN; 4, 21/2% FCBN LAJv-A-XJ UUJv-Aj X1 X3 X2 Interconnect Connect Lines to 504 H5 to H6 H1 & H10 492 H4 to H6 H1 & H10 480 H4 to H7 H1 & H10 468 H3 to H7 H1 & H10 456 H3 to H8 444 Connect Lines to 504 H4 to H5 H1 & H8 492 H3 to H5 H1 & H8 480 H3 to H6 H1 & H8 468 H2 to H6 H1 & H8 456 H2 to H7 H1 & H8 H1 to H5 H1 & H8 H4 to H8 240 H1 to H6 H3 to H8 H1 & H8 228 H1 to H7 H2 to H8 H1 & H8 Secondary Voltage Interconnect Connect Lines to X1 & X4 X2 to X3 X1 , X2 & X4 H1 H2 120 X1 to X3 X2 to X4 X1 & X4 (1 0 2 4 6 8 ^_A_/^^AAAA_AA>J V>^AAAAAAAAAA_. \(' X1 Primary Voltage X3 SHIELD X2 600 Volt Primary, 120/240 Volt Seco ndary Taps: None X4 Interconnect Connect Lines to 1 to 2 H1 & H2 2 to 3 H1 & H2 480 3 to 4 H1 & H2 468 4 to 5 H1 &H2 H1 & H10 456 5 to 6 H1 & H2 H2 to H8 H1 & H10 444 6 to 7 H1 & H2 432 H2 to H9 H1 & H10 432 7 to 8 H1 & H2 252 H1 to H6 H5to H10 H1 & H10 252 H1 to 2 H2to1 H1 & H2 240 H1 to H7 H4to H10 H1 & H10 240 H1 to 4 H2to3 H1 & H2 H3to H10 Interconnect X2 to X3 504 H1 to H8 X4 240 492 228 X2 120/240 X4 Primary Voltage '1 I SHIELD i* ** 7 5 3 1 -L o^rVv^, rv-vVv^ ~ ^xr SHIELD I r-^S I 3 Primary Voltage Connect Lines to 120/240 rv'YVv'V'w^ X3 252 X1 to X3 X2 to X4 H8 r^S X1 Primary Voltage H7 UV>LA_/LA^AJ prv>^rS^w~\ I H6 H1 t• H2 4i >~A_A^A_^A-A^A_A^VAA-A--VA^ t X1 Primary Vottage i X3 X2 Interconnect X4 Connect Lines to 600 H1 & H10 228 H1 to 6 H2to5 H1 & H2 6 H1 & H2 Secondary Voltage Interconnect Connect Lines to 240 X2 to X3 X1 & X4 216 H1 to H9 H2to H10 H1 & H10 216 H1 to 8 H2to 7 H1 & H2 120/240 X2 to X3 X 1 , X2& X4 Secondary Voltage Interconnect Connect Lines to Secondary Voltage Interconnect Connect Lines to 120 240 X2 to X3 X1 & X4 240 X2 to X3 X1 & X4 120/240 X2 to X3 X1.X2&X4 120/240 X2 to X3 X1.X2&X4 X1 &X4 120 X1 to X3 X2 to X4 X1 &X4 120 78 X1 to X3 X2 to X4 X1 to X3 X2 to X4 Note: 1 through 2 KVA units have electrostatic shielding. Fax-on-Demand #: (877) 888- 9329, Document #: 8334 Contact Technical Services at (800) 377-4384 with any questions. X1 &X4 SOLA/ HEVI-DUTY General Purpose Transformers Specification Guide for Low Voltage, General Purpose, Dry Type Transformers (600 Volt Class) -15 KVA and larger General Single and three phase distribution transformers (600 Volt and below) • Provide and install, as referenced on the electrical plans, enclosed dry type transformers as manufactured by Sola/Hevi-Duty or approved equal. Standards • Transformers must be listed by Underwriters Laboratory, certified with Canadian Standards Association and designed, constructed and rated in accordance with NEMA ST 20, ANSI C89.2 and applicable IEEE & OSHA specifications. Construction Cores • All transformer cores shall be constructed of low loss, high quality, electrical grade laminate steel. By design, the flux density is to be kept well below the saturation level to reduce audible sound level and minimize core losses. The core volume shall allow operation at 10% above rated primary voltage at no load without exceeding the temperature rise of the unit. Coils • Coil conductors shall be either aluminum or copper and must be continuous. The entire core and coil assembly shall be impregnated with a thermal setting varnish and cured to reduce hot spots in the coils and seal out moisture. Coils with exposed magnet wire will not be acceptable. Transformers shall have common core construction. • All transformers shall incorporate a faraday (electrostatic) shield between primary and secondary windings for the attenuation of voltage spikes, line noise and voltage transients. • Transformers shall be provided with six 2.5% full capacity taps - two above and four below primary rated voltage. Enclosures • Transformer enclosures shall be constructed of heavy gauge sheet steel and coated with a grey powder paint finish (ANSI 6 1 ) . Ventilated transformer enclosures shall be UL/NEMA Type 2 rated and UL/NEMA Type 3R rated for outdoor use with the addition of a weathershield. This information must be listed on the transformer nameplate. • Maximum transformer enclosure temperature will not exceed 65°C rise above a 40°C ambient under full load. • Transformers must have vibration isolators located between the core and coil assembly and the transformer enclosure to reduce audible sound levels caused from magnetostriction of the transformer core. No externally located vibration dampening pads shall be used as they tend to increase audible noise. Ventilated transformers are to be floor mounted to a concrete pad. • The transformer enclosure must be grounded by the installer in accordance with the latest edition of the National Electric Code and any local codes or ordinances. Performance • Audible sound levels will not exceed limits established in NEMA/ANSI Standard C89.2: 10 to 50 KVA 51 to 150 KVA 151 to 300 KVA 301 to 500 KVA • Transformers, 15 KVA to 500 KVA, shall incorporate a UL recognized 220°C insulation system and exhibit a maximum 150°C temperature rise above a maximum ambient of 40°C under full load. • General purpose transformers are classified as isolation transformers. 84 45 db 50 db 55 db 60 db Fax-on-Demand #: (877) 888-9329, Document #: 8336 Contact Technical Services at (800) 377-4384 with any questions.