Light–Duty Vehicle OBD Project

advertisement
EURO6
Light–Duty Vehicle OBD Project
Evaluation and Assessment of Proposed EOBD
Emission Thresholds
Q51760
2nd November 2010
RD.10/320201.4
Simon Finch
Bohumil Hnilicka
Hector Sindano
Authors:
Approved:
Dr Andy Noble
Project Director
Ricardo UK Limited Cambridge Technical Centre 400 Science Park Milton Road Cambridge CB4 0WH UK
Telephone: +44 (0) 1223 223200 Facsimile: +44 (0) 1223 223300 Registered in England No. 2815682
Registered Office: Shoreham Technical Centre Shoreham-by-Sea West Sussex BN43 5FG UK
RD.10/320201.4
TABLE OF CONTENTS
EXECUTIVE SUMMARY........................................................................................................3
1.
INTRODUCTION ........................................................................................................6
2.
TEST OBJECTIVES...................................................................................................6
3.
TEST STRUCTURE ...................................................................................................7
3.1
Emission Thresholds ......................................................................................8
3.2
Test Vehicles ..................................................................................................9
3.3
Test Cycle.....................................................................................................10
3.4
Component Degradation...............................................................................10
3.5
In-Use Performance......................................................................................17
4.
TEST RESULTS.......................................................................................................23
4.1
Upstream Oxygen Sensors (Gasoline)..........................................................23
4.2
Upstream & Downstream Lambda Sensors (Diesel LNT) .............................28
4.3
Downstream Lambda Sensors (Gasoline).....................................................43
4.4
3-Way Catalytic Converter (Gasoline)...........................................................48
4.5
Misfire Monitor (Gasoline).............................................................................54
4.6
Fuel System Monitor (Gasoline)....................................................................61
4.7
VVT System Monitor (Gasoline)....................................................................69
4.8
MAF Sensor Monitor (Gasoline)....................................................................75
4.9
Exhaust Gas Recirculation (Diesel)...............................................................79
4.10 EGR Cooler / ByPass (Diesel) ....................................................................104
4.11 NSC/LNT Monitor (Diesel) ..........................................................................107
4.12 Oxidation Catalyst (Diesel) .........................................................................118
4.13 Particulate Filter (Diesel).............................................................................129
4.14 SCR Monitor (Diesel) ..................................................................................157
5.
SUMMARY.............................................................................................................169
5.1
Gasoline Results.........................................................................................170
5.2
Diesel Results.............................................................................................171
6.
Conclusions..........................................................................................................172
6.1
Gasoline .....................................................................................................172
6.2
Diesel .........................................................................................................172
2 November 2010
© Ricardo plc 2010
Page 2
RD.10/320201.4
EXECUTIVE SUMMARY
The purpose of this report is to provide independently assessed information that will
support the necessary legislative process to confirm the Euro 6 OBD thresholds. The
capability of sensor technology and technology currently under development to achieve
reliable and robust detection of failures at the Euro 6 OBD thresholds which have been
proposed by the Commission, but which the Commission notes should be subject to
impact assessment by September 2010, are assessed in this report.
ACEA is of the opinion that the feasibility of technical measures to monitor against the
proposed Euro 6 OBD thresholds must be reviewed as soon as possible in order to
support the legislative process that will implement the appropriate Euro 6 OBD thresholds
while also providing sufficient industrial lead-time for compliance.
This report details the procedures and results of tests that were carried out by ACEA
members within confidential OBD development programs with their suppliers, in order to
evaluate and assess the feasibility of technical solutions needed to monitor against the
Euro 6 OBD thresholds proposed by the Commission and within the available lead-times
running up to the Euro 6 emissions stage which is mandatory from 2014.
Five vehicles from five different manufacturers were tested as part of this specific program.
Details of the vehicles tested are provided in Section 3.0 of this report.
The conclusions that can be drawn from the tests on spark-ignition engines are as
follows:
1. The proposed Euro 6 OBD thresholds were exceeded for NOx and NMHC with the
degraded catalysts used. Compared to the proposed Euro 6 OBD thresholds of
100 mg/km (NMHC) and 90 mg/km (NOx), detection was achieved with the current
calibration at 277 mg/km (NMHC) and 136 mg/km (NOx). However, further work is
required with less aggressively aged catalysts in order to make a definitive statement
about the feasibility of the monitoring techniques to detect failures at, or close to,
thresholds corresponding to those proposed for Euro 6.
2. The proposed Euro 6 OBD threshold was exceeded for NMHC with the 6 % misfire
level tested (277 mg/km versus proposed 100 mg/km). However, further work is
required with a reduced calibration threshold and lower misfire rate to make a definitive
statement about the robustness of the monitoring technique to detect failures at the
proposed Euro 6 threshold.
3. VVT System Monitoring successfully detected a Total Functional Failure (TFF),
however emissions exceeded the proposed EU6 EOBD thresholds (177 mg/km versus
proposed 100 mg/km). Further investigation would be required with revised monitor
thresholds and partial VVT failure to confirm that detection at the proposed threshold
level would not result in false fault detection.
4. Although PN and PM measurements were taken, in each case a specific trend was not
obvious and the proposed OBD and type approval thresholds were not exceeded in
any of the test measurements made.
2 November 2010
© Ricardo plc 2010
Page 3
RD.10/320201.4
The conclusions that can be drawn from the tests on compression-ignition engines
are as follows (note that these conclusions reflect the results from the different
compression-ignition vehicles tested):
1. The EGR low flow monitor was able to distinguish the baseline result (without a
malfunction) from a failure at the proposed EU6 EOBD emissions level (140 mg/km
NOx). However, to reduce the risk of false failure detection with partial degradation
and emissions within the type approval emission limit, more separation is required
between the type approval and EOBD thresholds.
2. None of the EGR high flow faults resulted in significant increase in emissions due to
the DPF effectively removing any additional PM. This failure is not a significant factor
in the determination of the EU6 OBD thresholds.
3. Neither the proposed Euro 6 NOx OBD threshold (140mg/km) nor the type approval
threshold (80 mg/km) was exceeded during an EGR Cooler / By-Pass total functional
failure. This failure is not a significant factor in the determination of the EU6 OBD
thresholds.
4. The NOx threshold achieved on the vehicle tested for NSC/LNT monitor was
approximately the proposed EU6 threshold (140mg/km). However, on the application
tested this represented a large scale failure of the NSC/LNT because of the relatively
low engine out NOx level. Additional work is required to confirm a threshold that can
be robustly detected by all engines.
5. In the case of DOC monitoring, emissions results for complete failure were below the
proposed Euro 6 OBD thresholds. However, this corresponded to total failure of the
DOC because tailpipe emissions were below 140 mg/km in this condition. The spread
of emissions results suggests that a partially failed DOC could not be robustly detected
for this vehicle.
6. DPF monitoring based on the current method of measuring differential pressure across
the DPF produced a best achievable PM threshold of 33.4 mg/km, which is over 3
times the proposed Euro 6 PM OBD threshold of 9 mg/km.
7. The best achievable PN threshold for DPF monitoring based on differential pressure
across the DPF was 41×1012/km, which is more than 30 times the proposed Euro 6 PN
OBD threshold of 1.2×1012/km.
8. DPF monitoring based on using prototype resistive PM sensor technology produced a
best achievable PM threshold of 14.5mg/km, which is 1.6 times the proposed Euro 6
PM OBD threshold of 9mg/km.
9. The best achievable PN threshold for DPF monitoring based on prototype resistive PM
sensor technology was 85×1012/km, which is more than 70 times the proposed Euro 6
PN OBD threshold of 1.2×1012/km.
2 November 2010
© Ricardo plc 2010
Page 4
RD.10/320201.4
10. The NOx threshold achieved on the vehicle tested for SCR monitor was approximately
the proposed EU6 threshold. However, on the application tested this represented a
large scale failure of the SCR system because of the relatively low engine out NOx
level. Additional work is required to confirm a threshold that can be robustly detected
by all engines.
In conclusion from the test program:
1. The Euro 6 OBD thresholds (CO, NMHC and NOx) proposed by the commission for
positive-ignition (gasoline) engines appear achievable for the majority of systems and
components, however, further testing of some monitors (e.g. misfire, 3WC, VVT) is
recommended to confirm robustness for production.
2. Where PN and PM measurements were acquired for positive-ignition engines, they
showed that the proposed OBD and type approval thresholds were not exceeded for
the faults considered (misfire, fuel system rich/lean). Therefore it is a low priority to set
PM and PN OBD thresholds for these faults.
3. The proposed PN OBD threshold for compression-ignition (diesel) engines is more
than an order of magnitude too low for monitoring by current and near-term sensor
technologies of differential pressure and resistive soot sensors.
4. Analysis of monitoring using prototype soot sensors appears to suggest that such
sensors could achieve a lower OBD PM threshold than differential pressure sensing
monitoring. However, the achievable threshold is higher than the proposed EU6 OBD
level.
In addition
1. PM (soot) sensors are in development and although some durability data was provided
in this report, a longer term evaluation of sensor durability in real driving conditions and
the effects of fuel quality and biodiesel content requires further consideration.
2. The effect of “intrusive” monitors on CO2 (and possibly other) emissions, has not been
addressed in this study. If intrusive monitors are required, it is recommended that the
effects on CO2 and other emissions be assessed as part of any impact assessment.
3. In addition, the effect of reducing OBD thresholds on the achievement of In Use
Performance Ratio (IUPR) requirements needs to be further considered, particularly
given the trend towards certain applications (e.g. hybrids, start-stop systems) expected
to have less frequent monitoring opportunities.
2 November 2010
© Ricardo plc 2010
Page 5
RD.10/320201.4
1.
INTRODUCTION
Regulations 715/2007(1) and 692/2008(2) set the Euro 5 and 6 emission requirements for
light duty vehicles. One major part of the Euro 5 and Euro 6 legislation relates to On Board
Diagnostics (OBD).
These Regulations specify the Euro 5 OBD requirements and also a Euro 6- diesel NOx
OBD threshold that might be used for incentivising early Euro 6 diesel vehicles. In mid2008, the Commission proposed(3) a set of positive-ignition and compression-ignition OBD
thresholds for Euro 6 that it intended to review by September 2010 based on an impact
assessment on the technical feasibility of achieving the proposed thresholds.
ACEA is of the opinion that the feasibility of technical measures to monitor against the
proposed Euro 6 OBD thresholds must be reviewed as soon as possible in order to
support the legislative process that will implement the appropriate Euro 6 OBD thresholds
while also providing sufficient industrial lead-time for compliance.
This document details the procedures and results of tests that were carried out by ACEA
members as part of confidential OBD development programs in order to evaluate and
assess the feasibility of technical solutions needed to monitor against the OBD thresholds
proposed by the Commission and within the available lead-times running up to the Euro 6
stage that applies from 2014.
2.
TEST OBJECTIVES
The purpose of the tests described in this document was to provide the sensitivity of the
monitored parameter and the tailpipe emissions in relation to the EOBD thresholds. This is
summarised in the following list:
•
The change in the OBD judgement variable in relation to the change in emissions,
resulting from component degradation. This is indicated by the trend line and ∆ in
the Figure below.
Judgement
variable
used for
OBD
Trend
ε
∆
Detectable
failure
ε
NOT Detectable
failure
Emissions
certification limit
(1)
(2)
(3)
Potential
OBD limit
NEDC
Emissions
Official Journal of the European Union, L171, 29.6.2007, p.1.
Official Journal of the European Union, L199, 28.7.2008 p.1.
Official Journal of the European Union, C182, 19.7.2008, p.17.
2 November 2010
© Ricardo plc 2010
Page 6
RD.10/320201.4
•
The capability of existing sensor technology and technology currently under
development to achieve detection at the Euro 6 OBD thresholds aspired to by the
Commission, taking into consideration the likely spread (dispersion) in the data as
indicated by ε in the Figure above.
•
Where the proposed EU6 thresholds cannot be achieved, the report has sought to
highlight what is the ‘best achievable’ OBD thresholds taking into account the
change in emissions, ∆, compared to the likely dispersion, ε, as shown in the
Figure above.
OBD monitors can be either “passive”, meaning that they perform within natural operating
conditions dictated by the driver’s behaviour or “intrusive”, meaning that they perform
under actively generated and precisely controlled test conditions. This study considers
mainly “passive” monitors. For most of the systems tested here, to investigate whether
OBD thresholds could be improved with intrusive monitoring techniques would require
development and prototyping of new software strategies and is outside the scope of this
study. It is expected that intrusive monitors may result in an increase in CO2 and
potentially other emissions, however this impact is not examined as part of this report.
Durability evaluation of sensors was not part of this study but remains a significant aspect
to consider for the application and integration of sensors in vehicle emission control
systems, especially in relation to real-driving performance and capability with different
biofuel blends.
3.
TEST STRUCTURE
As part of this project, five ACEA members conducted engine test programs following test
procedures produced by Ricardo, in conjunction with ACEA to investigate the relationship
between
•
Degradation of critical emissions control systems and the resulting increase in
emissions over the NEDC.
•
Performance of the OBD monitoring techniques currently available and the
degradation of the emissions control system
2 November 2010
© Ricardo plc 2010
Page 7
RD.10/320201.4
3.1
Emission Thresholds
3.1.1
Gasoline Vehicles
LIMITS
CO
(mg/km)
THC
(mg/km)
NMHC
(mg/km)
NOx
(mg/km)
PM
(mg/km)*
PN
12
(x10 /km)
EU6 Type Approval
1000
100
68
60
5 / 4.5
+
EU Commission Proposed
EU6 EOBD
1500
-
100
90
9
++
50
-
50
-
EU6 Interim EOBD
EU5 EOBD
1900
-
250
300
+ PM limit only applies to GDI engines
++ ×2 threshold to be considered once limit is set
* The 4.5 mg/km emission limit for PM shall be effective from 1 September 2011 for the
type-approval on new types and from 1 January 2013 for all new vehicles. A new
measurement procedure shall be introduced before the application of the limit value
3.1.2
Diesel Vehicles
LIMITS
CO
(mg/km)
THC
(mg/km)
NMHC
(mg/km)
NOx
(mg/km)
PM
(mg/km)*
PN
12
(x10 /km)
EU6 Type Approval
500
-
-
80
5 / 4.5
0.6
EU Commission Proposed
EU6 EOBD
750
-
140
140
9
1.2
EU6 Interim EOBD
1900
-
320
240
50
-
EU5 EOBD
1900
-
320
540
50
-
2 November 2010
© Ricardo plc 2010
Page 8
RD.10/320201.4
3.2
Test Vehicles
Five vehicles from 5 Manufacturers were tested as part of this program. These are detailed
below
Vehicle
Manuf 1
Components
Tested
•
Euro 5 certified
Oxygen Sensor
•
Emission control & After-treatment Equipment: EGR,
3WC
3WC
Fuel System
VVT
MAF
Manuf 2
Manuf 3
•
Euro 6, Emission
λ-sensor
•
Emission control & After-treatment Equipment: EGR,
NSC/DOC, DPF
LNT/NSC
•
Euro 6 (certified)
EGR
•
Emission control & After-treatment Equipment: EGR &
Cooler, DOC+DPF+SCR
EGR Cooler Bypass
DOC
DPF
SCR
Manuf 4
Manuf 5
2 November 2010
© Ricardo plc 2010
•
Euro 6 development state
•
Emission control & After-treatment Equipment:
DOC+DPF+SCR
•
Euro 4 emissions level (matches Euro 6 PM)
•
Emission control & After-treatment Equipment: EGR,
DOC, DPF
DPF
DPF
Page 9
RD.10/320201.4
3.3
Test Cycle
3.3.1
Pre-Conditioning
Before each test, pre-conditioning was carried out. This was dependent on the type of
vehicle and also the algorithm used to detect the malfunction. The following is a list of the
pre-conditioning cycles used:
3.3.2
Vehicle
Manufacturer
DPF
Regen
No. of
NEDC
No. of
EUDC
Cold
Soak
Manuf 1
1
-
Manuf 2
-
3
Manuf 3
1
-
Manuf 4
-
3
Manuf 5
-
3
Actual Test
•
Two NEDC tests from cold start were carried out for each level of system
degradation
•
Cold Start NEDC = 20 – 30°C
•
Additionally, in some cases each level was tested over 3x NEDC cycles starting
with a warm engine
•
Also to ensure accuracy of results in some cases 2 iterations of testing were
carried out.
3.4
Component Degradation
3.4.1
Oxygen Sensors (Gasoline & Diesel)
Real world experience suggests that the most likely failure mode that is not detectable by
electrical circuit continuity monitors is a gradual degradation of the sensor with age
resulting in slow response.
•
Manipulation of sensors in order to generate a slow response can be done by
installing a thimble over the tip of the sensing element.
•
Slower response sensors are generated by having fewer/smaller holes in the
thimble.
•
Level of degradation is defined by the number and size of holes in the thimble.
•
A range of parts are tested until the emissions threshold is exceeded.
2 November 2010
© Ricardo plc 2010
Page 10
RD.10/320201.4
3.4.2
3.4.3
3.4.4
Downstream Lambda Sensors (Gasoline)
•
Slow response lambda sensors are generated by using hardware simulation (Slug
box = 1.3)
•
A set of 2 or 3 tests was repeated to attain more consistent results
3-Way Catalyst (Gasoline)
•
Limit Catalysts - Artificially aged catalyst
•
A set of 3 to 6 tests was repeated to attain more consistent results
Misfire Monitor (Gasoline)
The following levels of degradation was implemented through internal EMS misfire
generator function
•
Misfire 2 % - Intermittent walking misfire across all cylinders
•
Misfire 6 % - Intermittent walking misfire across all cylinders
A set of 3 to 4 tests was repeated to attain more consistent results
3.4.5
Fuel System Monitor (Gasoline)
The following levels of degradation were implemented
•
Lean Fuel - Injector characteristic curve was multiplied by 0.8 to simulate fuel
system leaner than target by 20 %
•
Rich Fuel - Injector characteristic curve was multiplied by 1.2 or by 1.24 to simulate
fuel system richer than target by 20 %.
–
PN testing was conducted at a later date and so corresponds to a different
rich shift 1.2.
A set of 3 tests was repeated to attain more consistent results
3.4.6
Variable Valve Timing (VVT) Monitor (Gasoline)
The following levels of degradation were implemented
2 November 2010
© Ricardo plc 2010
Page 11
RD.10/320201.4
•
•
•
Slow response – Inlet and exhaust cam VVT set to 1 %
–
Closed loop control maps calibrated to simulate slow response to changing
target position
–
Principal effect observed on exhaust cam since inlet cam is parked at
NEDC operating points
Stuck 100 % - Inlet cam VVT stuck 100 %
–
Inlet cam target position map calibrated to 100% to simulate a cam phaser
stuck in the most advanced position
–
Inlet cam moves to maximum advance about 2 seconds after start following
sufficient oil pressure to mechanically unlock the cam phaser mechanism
Stuck 0 % - Exhaust cam VVT stuck 0 %
–
3.4.7
Slave exhaust cam phaser (stuck at 0%) fitted to test vehicle
MAF Sensor Monitor (Gasoline)
The following levels of degradation were implemented
•
Sensor drift (cold tests)
–
2 November 2010
© Ricardo plc 2010
MAF sensor characterisation calibration was multiplied by 1.3 to simulate
MAF sensor signal drift
Page 12
RD.10/320201.4
3.4.8
Exhaust Gas Recirculation (Diesel)
The following levels of degradation were implemented
•
High flow:
–
EGR valve position manipulated by an additional simulation block between
EGR valve and the ECU to:
•
Limit closing position of EGR valve by modifying the demand PWM
signal from the ECU, to simulate permanently open valve or valve
not seating properly
•
Modify the position feedback signal to the ECU to mimic the valve
being in the correct position and avoid a position sensor fault.
•
The following degradation levels of EGR low flow tests were
evaluated:
+ 15% => Valve closing point limited to 15 % of full travel
+ 25% => Valve closing point limited to 25 % of full travel
•
•
Low flow – alternative methods used:
–
2 November 2010
© Ricardo plc 2010
Higher levels of degradation could not be tested due to DPF
clogging and damage
Orifice plate was inserted after EGR valve to restrict flow
Page 13
RD.10/320201.4
•
The following degradation levels of EGR low flow tests were
evaluated:
base (0 %)
14 mm restrictor (-33 % reduction in EGR flow rate)
9 mm restrictor (-67 % reduction)
no flow, i.e. 0 mm restrictor (-100 %)
Two NEDC tests from cold start were carried out for each level of system degradation
3.4.9
NSC/LNT Monitor (Diesel)
Ageing of catalyst by extended high temperature operation on test bench engine
•
NSC’s were tested with the following levels of degradation:
–
0 % (new NSC)
–
1 % loss of efficiency
–
60 % loss of efficiency
–
95 % loss of efficiency
•
Emissions degradation was measured over 3x NEDC cycles
•
Additionally, each level was tested over 3x NEDC cycles starting with a warm
engine
3.4.10 EGR Cooler By-Pass (Diesel)
Two levels of EGR cooler performance were tested:
•
Baseline normal operation (0 % degradation)
•
Major/Total functional failure (100 % degradation)
Total function failure of the EGR cooler was simulated by bypassing the coolant circuit of
the EGR cooler
3.4.11 Oxidation Catalyst (Diesel)
A single level of DOC degradation was tested, simulated by an empty DOC can
Testing was carried out over the normal NEDC for measurement of emissions and
separately over an NEDC cycle with a DPF regeneration active in order to assess the
monitor judgement
2 November 2010
© Ricardo plc 2010
Page 14
RD.10/320201.4
3.4.12 Particulate Filter (Diesel)
To degrade the DPFs plugs were removed from the back face of the DPF. Different
removal strategies were followed by each Manufacturer. These are shown in the subsections below.
3.4.12.1
Manufacturer 3
The following levels of degradation were evaluated
3.4.12.2
•
9 % rearward area
•
50 % rearward area
•
Empty DPF Can, i.e. a major failure
Manufacturer 4
Plugs were removed from the face of the DPF as shown below:
DPFs were tested with the following levels of degradation applied:
2 November 2010
© Ricardo plc 2010
Page 15
RD.10/320201.4
DPF Ageing
3.4.12.3
% Degradation
Baseline: No plugs removed
(aged to FUL)
0
180 plugs removed
4
365 plugs removed
9
512 plugs removed
12
722 plugs removed
17
1800 plugs removed
43
Empty DPF can
100
Manufacturer 5
To degrade the DPFs used for testing, plugs were removed from the rear face of the DPF.
DPFs were tested with the following levels of degradation:
•
Baseline, no plugs removed
•
Plugs removed to target 6 mg/km PM emissions
•
Plugs removed to target 12 mg/km PM emissions
•
Empty DPF can (approximately 16 mg/km expected)
3.4.13 SCR Catalyst (Diesel)
It is assumed that low catalyst conversion efficiency has the same symptoms, regardless
of whether this is caused by degradation of the catalyst, dosing unit or regent quality.
The SCR catalyst conversion degradation is simulated by reducing the urea dosing
quantity without feedback to ECU.
The following levels of degradation were evaluated
•
50 % dosing
•
10 % dosing
2 November 2010
© Ricardo plc 2010
Page 16
RD.10/320201.4
•
3.5
0 % dosing, i.e. major functional failure
In-Use Performance
The Euro 6 legislation requires that OBD monitors meet minimum “in-use performance
ratios” are met and reported in service.
The In-Use Performance ratio is defined as the number of drive cycles in which the monitor
makes a judgement (numerator) to the number of drive cycles that meet legislated
minimum conditions (denominator)
•
Numerator conditions:
–
•
Monitor has completed all decisions that would be necessary to make a fail
judgement on this drive cycle
Denominator conditions:
–
10 minutes duration
–
5 minutes accumulated above 40 km/h
–
30 seconds uninterrupted (continuous) idle
–
And, other conditions for some specific monitors:, e.g.
•
•
3.5.1
for diesel particulate filter and oxidation catalyst, cumulative 800 km
driven since last time drive cycle was denominator was incremented
Minimum average ratio must be achieved:
–
0.336 for most monitors
–
Alternative targets for some specific monitors, e.g. gasoline evap/purge and
SAI
Model-Based Evaluation
In order to assess the capability of any OBD monitoring strategy, it is important to consider
whether the conditions required to make a judgement will allow the numerator to be
incremented with sufficient frequency in the typical range of real world driving
Ricardo have used a model based approach to assess this capability
•
Parametric model of vehicle coded in Simulink
–
Data used for a ‘typical’ diesel passenger car
•
Model of OBD monitor enable conditions for each monitor
•
The model does not take into account the effect of changes in ambient conditions
(i.e. model conditions are restricted to 20°C, constant altitude, and other ambient
variables).
•
2 November 2010
© Ricardo plc 2010
–
The effect of real ambient condition changes on engine operation may
reduce the frequency with which monitor enable conditions can be met
–
At some ambient conditions, in-use enablement could be significantly worse
than predicted by this model
Model is run over operating profiles from Ricardo database, developed to represent
different typical drive cycles:
Page 17
RD.10/320201.4
–
City driving cycles
•
London, Paris, Stuttgart, Turin
–
Rural drive cycle
–
Highway drive cycle
•
The simulation will show whether we would expect a monitor to increment the
numerator on each drive cycle, under the assumed ambient conditions.
•
If the numerator can be incremented in all the cycles, then we would expect that
the numerator will be incremented with sufficient frequency in real world use under
similar ambient conditions.
•
The following figure shows typical results that are obtained for each simulated drive
cycle (city specific or rural or highway) – in this case the results are based on use
of Manufacturer 2’s vehicle in London City Cycle
The graph which shows the duration when the monitor is enabled is the most important
one from the four graphs and therefore this is the only one that is provided in this
report, together with the detailed results for each monitor where data to allow this
evaluation to be carried out was available.
The reason for choosing the 4 European cities is as follows:
•
•
Paris
–
well known for its severe daily congestion
–
commuting patterns
London
–
2 November 2010
© Ricardo plc 2010
has been labelled the most congested city in Europe
Page 18
RD.10/320201.4
–
•
•
2 November 2010
© Ricardo plc 2010
has implemented congestion charging zone
Turin
–
representative of a large Italian city
–
sophisticated traffic control system
Stuttgart
–
traffic calming in the centre of town
–
a good public transport network
–
congestion in Stuttgart is typical of a German city of this size
Page 19
RD.10/320201.4
The following parameters have been used to construct the city cycles:
Paris
London
Stuttgart
Turin
10.1
5.3
5.77
5.7
Total time (sec)
1745.0
1076.5
1075.7
1075.3
Driving time (%)
84.8
83.2
82.9
76.6
Cruising time (%)
5.25
4.72
5.67
4.72
Standing time (%)
15.2
16.8
17.1
23.4
Avg driving speed (km/h)
22.7
20.9
22.8
23.5
Avg trip speed (km/h)
19.4
17.4
18.9
18.4
Maximum speed (km/h)
72.2
52.9
61.7
63.3
No. of stops per km
2.39
2.37
2.18
2.77
0.490
0.651
0.502
0.534
Avg. (-) accel (m/s )
-0.451
-0.555
-0.473
-0.500
No. of accels per km
15.7
18
16.4
13.3
Total distance (km)
2
Avg. (+) accel (m/s )
2
2 November 2010
© Ricardo plc 2010
Page 20
RD.10/320201.4
Client Confidential
The graphs below show an example of typical results for a specific monitor.
2 November 2010
© Ricardo plc 2010
Page 21
RD.10/320201.4
Client Confidential
European Automobile Manufacturers Association (ACEA)
A summary table is produced showing the number of times the monitor was
enabled during each of the cycles considered. The following notes should be
taken into consideration when interpreting these results:
•
The model considers monitoring enable conditions not only for enabling of the
monitor, but also that the conditions are enabled for sufficient time to make a
judgement.
•
At least one judgement made on each cycle:
•
2 November 2010
© Ricardo plc 2010
–
The monitor can be enabled over a sufficiently wide rage of conditions
–
We would expect it to be able to achieve minimum ratio requirements
–
Multiple judgements improves confidence
No judgements on a particular drive cycle:
–
The required monitoring conditions may be too selective
–
Minimum ratio requirements may be difficult to meet
Page 22
RD.10/320201.4
Client Confidential
4.
TEST RESULTS
4.1
Upstream Oxygen Sensors (Gasoline)
The table below gives NEDC emission results:
The tables below shows emissions for CO, NOx, NHMC, and PM components did not exceed proposed EU6 OBD emission threshold
for all levels of degradation tested
2 November 2010
© Ricardo plc 2010
Page 23
RD.10/320201.4
Client Confidential
Emissions vs. 'level of degradation'
Manuf 1
EU6 prop OBD
EU5 OBD
250
200
150
100
Manuf 1
EU6 prop OBD
EU5 OBD
1500
CO [mg/km]
300
NOx [mg/km]
Emissions vs. 'level of degradation'
2000
1000
500
50
0
Base
0
Slow response
Degradation
Base
Emissions vs. 'level of degradation'
Emissions vs. 'level of degradation'
300
NMHC [mg/km]
200
150
100
Manuf 1
EU6 prop OBD
EU5 OBD
40
30
20
10
50
0
50
PM [mg/km]
Manuf 1
EU6 prop OBD
EU5 OBD
250
Slow response
Degradation
Base
Slow response
Degradation
2 November 2010
© Ricardo plc 2010
0
Base
Slow response
Degradation
Page 24
RD.10/320201.4
Client Confidential
4.1.1
Evaluation of OBD Monitor Strategy
Vehicle speed [km/h]
Upstream lambda sensor monitoring is achieved by inducing fuelling oscillation and measuring sensor response. A fault is set if the
calculated lambda rate of response is above a calibratable threshold. The figure below shows the target lambda values for response
rate thresholds measured over an NEDC.
Vehicle speed
Base
Slow response
100
50
0
0
200
400
600
800
1000
1200
1000
1200
1000
1200
Target lambda (bank 1)
Lambda [-]
1.2
1
0.8
0
200
400
600
800
Target lambda (bank 2)
Lambda [-]
1.2
1
0.8
0
2 November 2010
© Ricardo plc 2010
200
400
600
Time [s]
800
Page 25
RD.10/320201.4
Client Confidential
Vehicle speed [km/h]
The figure below shows the lambda sensor response rate monitor parameter measured over an NEDC
Vehicle speed
100
Base
Slow response
50
0
0
200
400
600
800
1000
1200
1000
1200
1000
1200
Upstream O2 sensor lambda (bank 1)
Lambda [-]
2
1.5
1
0.5
0
200
400
600
800
Upstream O2 sensor lambda (bank 2)
Lambda [-]
2
1.5
1
0.5
0
2 November 2010
© Ricardo plc 2010
200
400
600
Time [s]
800
Page 26
RD.10/320201.4
Client Confidential
The figure below shows the lambda sensor response rate monitor output measured over an NEDC
2 November 2010
© Ricardo plc 2010
Page 27
RD.10/320201.4
Client Confidential
4.1.2
4.2
Conclusion
•
The proposed EU6 EOBD emissions thresholds were not exceeded for any emissions species (NOx, CO, NMHC and PM) with
slow response faults on the upstream lambda sensor
•
A monitoring strategy (using an induced fuelling oscillation and measuring the sensor response) was capable of identifying the
degraded component for upstream sensor
•
Sensor accuracy has not been studied because of data were not available
•
Analysis of the likely monitor enabled conditions over typical real world driving cycles has not been carried out because of data
were not available
•
The proposed EU6 OBD limits would be achievable for monitoring of lambda sensor
•
Where the work indicates that a lower fault threshold is required then in order to set diagnostic thresholds for production
vehicles, it will be necessary to consider the robustness of the monitor results on correctly functioning vehicles
Upstream & Downstream Lambda Sensors (Diesel LNT)
In this case both lambda sensors are used for after-treatment emission control.
•
Upstream lambda sensor is used for Closed-loop control of air/fuel ratio for the rich mixture required during regeneration
•
Downstream lambda sensor is used for the Diagnosis of degraded NSC/LNT efficiency for OBD by comparing with upstream
lambda measurement during regeneration
•
Downstream lambda sensor is used to sense the end state of NSC regeneration in normal operation
The table below gives NEDC emission results.
2 November 2010
© Ricardo plc 2010
Page 28
RD.10/320201.4
Client Confidential
All emissions species remained within the type approval limits with the degraded components installed.
2 November 2010
© Ricardo plc 2010
Page 29
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 30
RD.10/320201.4
Client Confidential
4.2.1
Evaluation of OBD Monitor Strategy
Analysis of the monitor capability is based on Manuf 2 existing lambda monitoring algorithm. This outlined below:
•
•
2 November 2010
© Ricardo plc 2010
Monitor enable conditions
–
DeNOx regeneration activated
–
Dew detection released
Monitor strategy
–
Evaluation of lambda sensor delay time if monitoring is enabled
–
If delay times ( ∆t Us→Ds , ∆t Ds→ Us) exceeded the threshold values (∆t thres, Us→ Ds , ∆t thres, Ds→ Us) then the error counter is
incremented
–
A given number of increments is needed to detect slow response sensors
–
Lambda monitoring is done immediately after switching into rich mixture for NSC regeneration
Page 31
RD.10/320201.4
Client Confidential
–
If the value of one lambda sensor falls below lambda threshold a timer starts. Time will be stopped if the value of the
second lambda sensor also falls below lambda threshold. The passed time is a judgement parameter for lambda monitor
and is compared with a given threshold time.
–
If the delay of the slower lambda sensor is too high a lambda control fault will be set (monitoring strategy up/down
counter).
For the purpose of this report a judgment parameter is defined by the time delay of the first regeneration because the following time
delays (corresponding to the next regenerations) are influenced by the time length between the following regenerations. The following
figures show analysis using this monitor judgement parameter.
The first figure shows results of the baseline test, with upstream and downstream lambda sensors set to 0 % degradation
2 November 2010
© Ricardo plc 2010
Page 32
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 33
RD.10/320201.4
Client Confidential
The next figure below shows results with upstream lambda sensor degraded by 100 %
2 November 2010
© Ricardo plc 2010
Page 34
RD.10/320201.4
Client Confidential
And finally the figure below shows results with downstream lambda sensor degraded by 100 %
2 November 2010
© Ricardo plc 2010
Page 35
RD.10/320201.4
Client Confidential
All these results are summarised in the following set of graphs to illustrate performance against the proposed OBD thresholds.
Calculated judgement parameter shows good separation between normal and degraded components for both upstream and
downstream lambda sensors. Ability to detect faulty components on the NEDC cycle is good.
4.2.1.1
Upstream Sensor Monitor Robustness
We have assumed a typical lambda sensor tolerance of up to 0.05 λ at lean air/fuel ratios
The effect of lambda sensor tolerance on the time delay of the first regeneration can be seen below to be small compared to the
separation between the normal and faulty component.
2 November 2010
© Ricardo plc 2010
Page 36
RD.10/320201.4
Client Confidential
•
The tolerance effect is much smaller than the other test to test variations in the data
–
•
2 November 2010
© Ricardo plc 2010
The effect of sensor tolerance cannot be seen in the graph
There is good separation between results with baseline and faulty parts
Page 37
RD.10/320201.4
Client Confidential
–
4.2.1.2
Monitoring should be robust to tolerance effects
Downstream Sensor Monitor Robustness
We have assumed a typical lambda sensor tolerance of up to 0.05 λ at lean air/fuel ratios
The effect of the lambda sensor tolerance on the time delay of the first regeneration can be seen below to be small compared to the
separation between the normal and faulty component
2 November 2010
© Ricardo plc 2010
Page 38
RD.10/320201.4
Client Confidential
•
The tolerance effect is much smaller than the other test to test variations in the data
–
•
There is good separation between results with baseline and faulty parts
–
4.2.2
The effect of sensor tolerance cannot be seen in the graph
Monitoring should be robust to tolerance effects
Evaluation of Monitor IUMPR
The Ricardo model was calibrated over the NEDC test cycle so that the modelled monitor enable conditions were met at the same time
in the cycle as the Manuf 2 monitor is enable in the test data
•
The lambda sensor monitor is enabled only during NSC regeneration
•
The in-use performance model was modified to simulate NSC regeneration frequency and estimated NSC regeneration enable
conditions to match the NSC regeneration conditions encountered in the NEDC test data
•
The enable conditions for lambda sensor monitoring were:
–
DeNOx regeneration activated
–
900 rev/min < Engine speed < 3000 rev/min
–
Vehicle speed > 30 km/h
–
Torque up to just below full power, torque < 240 Nm
–
Dew detection of lambda downstream (lambda controlled DeNOx mode), enable time > 450 s
•
•
2 November 2010
© Ricardo plc 2010
Dew release is strongly dependant on general vehicle load and driving conditions
–
Gear > 1
–
Time required for monitor judgement 3 s
The following figures show the results for each simulated drive cycle
Page 39
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 40
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 41
RD.10/320201.4
Client Confidential
The table below summarises in-use performance ratio assessment from the above results.
CYCLE
Number of
Judgements
London
1
Paris
1
Stuttgart
4
Turin
2
Rural
3
Highway
7
The monitor was enabled over all the conditions evaluated. We would therefore expect this monitor to achieve minimum ratio
requirements robustly. Best monitoring robustness is achieved under highway driving conditions.
4.2.3
Conclusion
•
The proposed EU6 EOBD emissions threshold were not exceeded for any emissions species with slow response faults on either
the upstream or downstream lambda sensors used for NSC control
•
A monitoring strategy based on time delay measurement between lambda output signals during NSC regeneration was capable
of identifying the degraded components for both upstream and downstream sensors
•
Sensor accuracy has a minimum influence on the robustness of the suggested strategy indicating that the judgement parameter
is capable of making a robust detection over a real fleet in real world conditions
2 November 2010
© Ricardo plc 2010
Page 42
RD.10/320201.4
Client Confidential
4.3
•
Analysis of the likely monitor enabled conditions over typical real world driving cycles suggests that the monitor is capable of
meeting the legislated minimum in-use performance ratio requirements
•
The proposed EU6 OBD limits would be achievable for monitoring of lambda sensors upstream and downstream of NSC
Downstream Lambda Sensors (Gasoline)
This refers to HEGO sensors located downstream of the catalyst for the purpose of monitoring the performance of the catalyst. The
table below gives NEDC emission results:
The tables below shows emissions for CO, NOx, NHMC, and PM components did not exceed proposed EU6 OBD emission threshold
for all levels of degradation tested
2 November 2010
© Ricardo plc 2010
Page 43
RD.10/320201.4
Client Confidential
Emissions vs. 'level of degradation'
Emissions vs. 'level of degradation'
2000
Manuf 1
EU6 prop OBD
EU5 OBD
NOx [mg/km]
250
200
150
100
Manuf 1
EU6 prop OBD
EU5 OBD
1500
CO [mg/km]
300
1000
500
50
0
Base
0
Slow response
Base
Emissions vs. 'level of degradation'
Emissions vs. 'level of degradation'
300
NMHC [mg/km]
200
150
100
Manuf 1
EU6 prop OBD
EU5 OBD
40
30
20
10
50
0
50
PM [mg/km]
Manuf 1
EU6 prop OBD
EU5 OBD
250
Slow response
Degradation
Degradation
Base
Slow response
Degradation
2 November 2010
© Ricardo plc 2010
0
Base
Slow response
Degradation
Page 44
RD.10/320201.4
Client Confidential
4.3.1
Evaluation of OBD Monitor Strategy
Downstream O2 sensor monitoring is performed by evaluating sensor response during rich to lean transitions when fuel cut is activated.
A fault is set if the measured sensor response time is greater than a calibratable threshold.
The figure below shows the target lambda values for response rate thresholds measured over an NEDC.
2 November 2010
© Ricardo plc 2010
Page 45
RD.10/320201.4
Vehicle speed [km/h]
Client Confidential
Vehicle speed
Base
Failure catalyst
100
50
0
0
200
400
600
800
1000
1200
1000
1200
1000
1200
Catalyst monitor fuelling control active (bank 1)
Flag [-]
1
0.5
0
0
200
400
600
800
Catalyst monitor fuelling control active (bank 2)
Flag [-]
1
0.5
0
0
2 November 2010
© Ricardo plc 2010
200
400
600
Time [s]
800
Page 46
RD.10/320201.4
Client Confidential
4.3.2
Conclusion
•
The proposed EU6 EOBD emissions thresholds for NOx, CO, NMHC and PM were not exceeded for all slow response faults
induced in the downstream O2 sensor
•
A monitoring strategy (evaluating sensor response during rich to lean transitions when fuel cut is activated) was capable of
identifying the degraded component for downstream sensor
•
Sensor accuracy has not been studied because data were not available
•
Analysis of likely monitor enabled conditions over typical real world driving cycles has not been carried out because data were
not available
•
The proposed EU6 OBD limits would be achievable for monitoring of the downstream O2 sensor
•
Where the work indicates that a lower fault threshold is required then in order to set diagnostic thresholds for production
vehicles, it will be necessary to consider the robustness of the monitor results on correctly functioning vehicles
2 November 2010
© Ricardo plc 2010
Page 47
RD.10/320201.4
Client Confidential
4.4
3-Way Catalytic Converter (Gasoline)
The table below gives NEDC emission results:
The next two sets of results show that while emissions for CO and PM did not exceed proposed EU6 OBD emission threshold for all
levels of degradation evaluated, nevertheless those for NOx and NMHC emissions exceeded proposed EU6 OBD emission threshold
when failure cats were fitted.
2 November 2010
© Ricardo plc 2010
Page 48
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 49
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 50
RD.10/320201.4
Client Confidential
4.4.1
Evaluation of OBD Monitor Strategy
The catalyst monitor operates by cycling fuelling rich and lean under certain operating conditions. Upstream and downstream oxygen
sensor signals are analysed to determine the level of oxygen storage in the catalyst hence inferring catalyst efficiency
2 November 2010
© Ricardo plc 2010
Page 51
RD.10/320201.4
Vehicle speed [km/h]
Client Confidential
Vehicle speed
Base
Failure catalyst
100
50
0
0
200
400
600
800
1000
1200
1000
1200
1000
1200
Catalyst monitor fuelling control active (bank 1)
Flag [-]
1
0.5
0
0
200
400
600
800
Catalyst monitor fuelling control active (bank 2)
Flag [-]
1
0.5
0
0
2 November 2010
© Ricardo plc 2010
200
400
600
Time [s]
800
Page 52
RD.10/320201.4
Client Confidential
4.4.2
Conclusion
•
The proposed EU6 EOBD emissions thresholds for NOx and NMHC were exceeded for tests carried out with degraded catalysts
•
Proposed EU6 EOBD emissions thresholds for CO and PM were not exceeded for all tests carried out
•
A monitoring strategy (based on the analysis of the upstream and downstream oxygen sensor signals) was capable of identifying
the degraded catalyst used in these tests
•
Catalyst monitor accuracy has not been studied because data were not available
•
Analysis of the likely monitor enabled conditions over typical real world driving cycles has not been carried out because data
were not available
•
A less aggressively aged catalyst (giving NOx and NMHC just below the proposed EU6 OBD threshold) was not available for
testing
•
In order to make a definitive statement about the feasibility of monitoring techniques for EU6 OBD tests, a less aggressively
aged catalyst is required.
•
Where the work indicates that a lower fault threshold is required then in order to set diagnostic thresholds for production
vehicles, it will be necessary to consider the robustness of the monitor results on correctly functioning vehicles
2 November 2010
© Ricardo plc 2010
Page 53
RD.10/320201.4
Client Confidential
4.5
Misfire Monitor (Gasoline)
The table below gives NEDC emission results:
2 November 2010
© Ricardo plc 2010
Page 54
RD.10/320201.4
Client Confidential
The set of results below show that emissions for NOx and CO did not exceed proposed EU6 OBD emission threshold for all levels of
degradation evaluated.
Emissions vs. 'level of degradation'
Manuf 1
EU6 prop OBD
EU5 OBD
NOx [mg/km]
250
200
150
100
Manuf 1
EU6 prop OBD
EU5 OBD
1500
CO [mg/km]
300
Emissions vs. 'level of degradation'
2000
1000
500
50
0
Base
Misfire 2 %
Degradation
Misfire 6 %
0
Base
Misfire 2 %
Degradation
Misfire 6 %
Results for PM emissions were also similar in that they did not exceed proposed EU6 OBD emission threshold for all levels of
degradation evaluated.
However results for NMHC exceeded the proposed EOBD thresholds at the level of degradation of 6% misfire.
2 November 2010
© Ricardo plc 2010
Page 55
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 56
RD.10/320201.4
Client Confidential
PN results were also measured although the EU have not as yet proposed a limit for this in GDI applications. These results are given in
the graph below.
Emissions vs. 'level of degradation'
6
PN [x1012/km]
5
4
3
2
Manuf 1
EU6 prop OBD (to be defined)
EU5 OBD (not defined)
1
0
4.5.1
Base
Misfire 2 %
Degradation
Misfire 6 %
Evaluation of OBD Monitor Strategy
Misfire detection is made by analysis of changes in Crankshaft Speed Fluctuations (CSF), since a misfire will cause a fall in speed after
a faulty firing event. An adaptive algorithm is used to reduce engine to engine effects. Multiple methods of detection are used to improve
detection capability.
2 November 2010
© Ricardo plc 2010
Page 57
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 58
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 59
RD.10/320201.4
Client Confidential
4.5.2
Conclusion
•
Misfire at 2 % and 6 % did not cause emissions to exceed proposed EU6 OBD emission threshold limits (CO, PM, NOx)
•
NMHC emissions exceeded proposed EU6 OBD emission threshold with a 6 % misfire rate
•
A misfire monitor strategy based on the analysis of changes in crankshaft speed was shown to be capable of identifying the 6 %
misfire fault. No fault detection was possible in the case of 2 % misfire because this was below the calibrated threshold (although
misfires were correctly identified)
•
The results suggest that a monitor calibration target of less than 6 % misfire rate may be necessary. This increases the risk of
false fault detection, however, misfire monitor accuracy and robustness under normal driving conditions has not been studied in
this work.
•
PN emissions are not sensitive to this failure mode
2 November 2010
© Ricardo plc 2010
Page 60
RD.10/320201.4
Client Confidential
4.6
Fuel System Monitor (Gasoline)
The table below gives NEDC emission results:
2 November 2010
© Ricardo plc 2010
Page 61
RD.10/320201.4
Client Confidential
Results below show CO emissions exceeded proposed EU6 OBD emission threshold when a rich fuelling fault is induced. PM and NOx
emissions did not exceed proposed EU6 OBD emission threshold limit under both lean and rich fuelling conditions.
2 November 2010
© Ricardo plc 2010
Page 62
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 63
RD.10/320201.4
Client Confidential
Although NMHC emissions did not exceed proposed EU6 OBD emission threshold limit under both lean and rich fuelling conditions,
nevertheless the results were very close to the limit under rich conditions – this requires further investigation to ensure robustness of
any monitoring techniques.
Again PN results are included for completeness – but no thresholds are defined yet.
4.6.1
Evaluation of OBD Monitor Strategy
Fuel system monitoring strategy is based on analysis of the long-term fuel system adaptations. If long-term adaptations exceed the
calibrated thresholds for a pre-determined time then a fault is set. Separate thresholds are calibrated for rich and lean sided faults.
The figures below show examples of Fuel System monitor performance:
2 November 2010
© Ricardo plc 2010
Page 64
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 65
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 66
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 67
RD.10/320201.4
Client Confidential
4.6.2
Conclusion
The following general trends were observed for the lean and rich air/fuel mixture faults:
•
CO emissions increase when the rich air/fuel mixture fault occurs, and exceed proposed EU6 OBD threshold limits
•
There is no significant change in NOx and PM emissions when either rich or lean faults are introduced, in comparison to the
base configuration
•
NMHC emissions increase when the rich air/fuel mixture fault occurs
•
Emissions of NOx, NMHC and PM did not exceed proposed EU6 OBD thresholds for either rich or lean air/fuel mixture faults
•
The monitoring strategy based on analysis of long-term fuel system adaptations is capable of identifying lean and rich fuel
system malfunctions
•
Monitor accuracy and robustness over a wide range of typical real world driving cycles has not been analyzed due to data not
being available
•
Based on the results in this report, however, the proposed EU6 OBD limits would be achievable for fuel system monitoring based
on analysis of long-term fuel system adaptations
•
PN emissions are not sensitive to rich mixture malfunctions tested
•
Where the work indicates that a lower fault threshold is required then in order to set diagnostic thresholds for production
vehicles, it will be necessary to consider the robustness of the monitor results on correctly functioning vehicles
2 November 2010
© Ricardo plc 2010
Page 68
RD.10/320201.4
Client Confidential
4.7
VVT System Monitor (Gasoline)
The table below gives NEDC emission results:
NMHC emissions exceed proposed EU6 OBD emission threshold when inlet VVT cam is stuck at 100 % . CO emissions did not exceed
proposed EU6 OBD emission threshold limit under all levels of degradation for VVT cam. The CO emissions are quite high when 100 %
stuck degradation is introduced, although less than the proposed OBD threshold.
NOx and PM emissions did not exceed proposed EU6 OBD emission threshold limits under all levels of degradation for VVT cam
2 November 2010
© Ricardo plc 2010
Page 69
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 70
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 71
RD.10/320201.4
Client Confidential
4.7.1
Evaluation of OBD Monitor Strategy
If the cam position error is higher than a threshold then a time counter is incremented. When the time counter value exceeds a
calibrated threshold (set to 10 seconds presently) then the VVT monitor detects a malfunctioning system.
The first set of results show performance of VVT monitor when valve is stuck open at 100%
Note that both banks detect a fault during the pre-conditioning cycle.
2 November 2010
© Ricardo plc 2010
Page 72
RD.10/320201.4
Client Confidential
The next set of results below show performance of VVT monitor when valve is stuck open at 0%. In this case the fault gets detected
within 500 seconds of the NEDC test cycle.
The final set of results show the effect of a slow actuator response malfunction. The monitor was able to detect the fault on bank 1 in
726 seconds, but the fault was not detected on Bank 2.
2 November 2010
© Ricardo plc 2010
Page 73
RD.10/320201.4
Client Confidential
4.7.2
Conclusion
•
Faults caused by the VVT slow response and VVT stuck 0 % do not cause emissions to exceed proposed EU6 OBD threshold
limits for all emissions (NOx, CO, NMHC, PM)
•
Fault caused by the VVT stuck in 100 % position causes NHMC emissions to exceed proposed EU6 OBD threshold limit
•
A change to the monitor detection threshold may be all that is required. However this needs to be verified
•
A VVT monitor strategy is inherently robust because it is based on a direct measurement of cam position error. However monitor
accuracy has not been studied in this report because data were not available
2 November 2010
© Ricardo plc 2010
Page 74
RD.10/320201.4
Client Confidential
4.8
•
Analysis of the likely monitor enabled conditions over typical real world driving cycles has not been done because of data were
not available
•
A VVT monitoring strategy based on the analysis of cam position error is capable of detecting faults to the level of proposed EU6
OBD thresholds
•
Where the work indicates that a lower fault threshold is required then in order to set diagnostic thresholds for production
vehicles, it will be necessary to consider the robustness of the monitor results on correctly functioning vehicles
MAF Sensor Monitor (Gasoline)
The table below gives NEDC emission results:
2 November 2010
© Ricardo plc 2010
Page 75
RD.10/320201.4
Client Confidential
The results are plotted below showing that NOx, NMHC, PM and CO emissions did not exceed proposed EU6 OBD emission threshold
limit for all levels of degradation evaluated (base and sensor reading drifted high).
Emissions vs. 'level of degradation'
Emissions vs. 'level of degradation'
Manuf 1
EU6 prop OBD
EU5 OBD
NOx [mg/km]
250
200
150
100
250
NMHC [mg/km]
300
200
150
100
50
50
0
Manuf 1
EU6 prop OBD
EU5 OBD
0
Base
Rich
Base
Degradation
Emissions vs. 'level of degradation'
Emissions vs. 'level of degradation'
2000
CO [mg/km]
1000
500
0
© Ricardo plc 2010
Manuf 1
EU6 prop OBD
EU5 OBD
40
30
20
10
Base
Rich
Degradation
2 November 2010
50
PM [mg/km]
Manuf 1
EU6 prop OBD
EU5 OBD
1500
Rich
Degradation
0
Base
Rich
Degradation
Page 76
RD.10/320201.4
Client Confidential
4.8.1
Evaluation of OBD Monitor Strategy
MAF sensor monitoring is achieved by comparing the measured airflow with an estimated airflow which is calculated from a model. A
fault is detected if the measured value deviates from the modelled value by more than a calibratable threshold
Engine air flow (from air charge estimation)
70
Base
Rich
Air flow [g/s]
60
50
40
30
20
10
0
0
200
400
600
800
1000
1200
800
1000
1200
Vehicle speed
Vehicle speed [km/h]
120
100
80
60
40
20
0
0
2 November 2010
© Ricardo plc 2010
200
400
600
Time [s]
Page 77
RD.10/320201.4
Client Confidential
4.8.2
Conclusion
•
All pollutants are insensitive to a rich airflow malfunction on the MAF sensor
•
A monitoring strategy based on comparing the measured airflow with an estimated (modelled) airflow is capable of detecting a
drift in MAF sensor signal reading high by 30% or more
•
Sensor accuracy has not been studied because data were not available
•
In order to fully evaluate the capability of MAF sensor monitoring techniques with regard to their feasibility for detecting proposed
EU6 OBD limits, data covering a wider range of failure needs to be analysed (e.g. MAF sensor signal drifting low)
•
However based on the results presented in this report, MAF sensor malfunctions to the level proposed in EU6 OBD can be
diagnosed using model-based diagnostic strategies
•
Where the work indicates that a lower fault threshold is required then in order to set diagnostic thresholds for production
vehicles, it will be necessary to consider the robustness of the monitor results on correctly functioning vehicles
2 November 2010
© Ricardo plc 2010
Page 78
RD.10/320201.4
Client Confidential
4.9
Exhaust Gas Recirculation (Diesel)
The tables below give NEDC emission results from manufacturer 3 that carried out EGR flow monitor tests.
The main emission species of interest are NOx for EGR low flow and CO and NMHC for EGR high flow. PM is not the main focus here
because the DPF is not damaged.
•
NOx emissions were very close to proposed EU6 EOBD threshold with 9 mm EGR flow restrictor
•
CO emissions are well below proposed EU6 EOBD threshold
•
NMHC emissions are well below proposed EU6 EOBD threshold. There is overall a slight increase in NHMC with EGR high flow,
although the results are not consistent over both test iterations
2 November 2010
© Ricardo plc 2010
Page 79
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 80
RD.10/320201.4
Client Confidential
4.9.1
4.9.1.1
Evaluation of EGR OBD Monitor Strategy
Manufacturer 2
Details of the Manuf 2 EGR flow monitoring strategies were not available and monitor parameters were not logged during the testing
•
Manuf 2 have previously certified the same EGR monitor to detect the levels of malfunction tested in the program
•
Both the EGR high and EGR low flow monitors successfully detected the degraded components tested during this program
•
Tailpipe NOx emissions do not increase significantly until NSC overload occurs:
–
Significant levels of EGR flow reduction can be tolerated before the OBD limits are exceeded
–
Monitoring of the EGR flow rate at this level over the NEDC is possible to detect
–
Real world emissions may be considerably worse since the NEDC is mainly low speed and load operation
•
4.9.1.2
The NSC will become overloaded sooner at higher speed load conditions
Manufacturer 3
Analysis of the monitor capability based on Manuf 3 existing EGR high and low flow monitoring algorithms is outlined below
•
2 November 2010
© Ricardo plc 2010
EGR Low flow:
–
Monitoring using mass air flow sensor
–
Judgement parameter is difference between desired and actual air mass flow
Page 81
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 82
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 83
RD.10/320201.4
Client Confidential
•
2 November 2010
© Ricardo plc 2010
EGR High Flow
–
Monitoring using mass air flow sensor during overrun
–
Judgement parameter is ratio of modelled air flow (using intake air pressure and temperature, engine speed and volume)
to measured mass air flow from sensor
Page 84
RD.10/320201.4
Client Confidential
Four steady state speed and load conditions of the NEDC cycle were considered for evaluating the performance both the low flow and
the high flow monitors:
•
Vehicle speed stable conditions defined by Ricardo: a), b), c) and d)
•
These conditions do not necessarily reflect Manuf 3 current calibration of monitor enable conditions but were chosen to assess
the potential for the monitor to be calibrated in these condition
The figures below show EGR low flow monitor judgment parameter versus NEDC NOx at each steady state condition
2 November 2010
© Ricardo plc 2010
Page 85
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 86
RD.10/320201.4
Client Confidential
In the figure below the low flow monitor judgment parameter versus NEDC NOx is presented showing results from only three steady
state conditions a), c) and d) from the previous figure
Condition b) is excluded as the fault could not be distinguished and a false pass would be possible. There is good separation between 9
mm and 14 mm restrictors to allow detection at the EU6 threshold at conditions a), c) and d)
2 November 2010
© Ricardo plc 2010
Page 87
RD.10/320201.4
Client Confidential
The air mass governor deviation was generally below the currently calibrated lower threshold limit of –100 mg/stroke when the monitor
was enabled during the NEDC cycle with 9 mm restrictor. The monitor would have detected the fault during this test with the current
calibration
2 November 2010
© Ricardo plc 2010
Page 88
RD.10/320201.4
Client Confidential
The EGR high flow monitor is enabled during overrun fuel cut-off with a warm engine. It is enabled three times during NEDC: conditions
a), b) and c). The results are shown below:
2 November 2010
© Ricardo plc 2010
Page 89
RD.10/320201.4
Client Confidential
The figure below shows the EGR high flow monitor judgment parameter (ratio) during conditions (a) and (b) of NEDC:
2 November 2010
© Ricardo plc 2010
Page 90
RD.10/320201.4
Client Confidential
The figure below shows the EGR high flow monitor judgment parameter (ratio) during conditions (c) of NEDC:
2 November 2010
© Ricardo plc 2010
Page 91
RD.10/320201.4
Client Confidential
The figures below show EGR high flow monitor judgment parameter versus NEDC NOx at each steady state condition, giving Mean and
standard deviation of judgment parameters at each separate occurrence of monitor enabling. Results shown are from 1st iteration of
testing. Emissions measurement was inconsistent but significantly below EOBD limit
2 November 2010
© Ricardo plc 2010
Page 92
RD.10/320201.4
Client Confidential
4.9.1.3
Monitor Robustness
The following tolerance data was provided by Manuf 3 for the OBD monitor input parameters
•
EGR low flow monitor
System
•
Tolerance
Air Flow Sensor
7%
Engine Displacement Volume
5%
EGR high flow monitor
System
Tolerance
Air Flow Sensor
7%
Engine Displacement Volume
5%
Intake Manifold Air Temperature Sensor
2%
Intake Manifold Pressure Sensor
2%
The next figure is a repeat of the results presented earlier, but with tolerance bands applied
2 November 2010
© Ricardo plc 2010
Page 93
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 94
RD.10/320201.4
Client Confidential
•
Plot below shows tolerance analysis of mean value of air mass governor deviation for a vehicle speed of 32 km/h
•
Assuming that the Worst Performing Acceptable (WPA) is at the type approval emissions limit and the Best Performing
Unacceptable (BPU) at the EU6 emissions limit, there is overlap between the upper and lower envelopes of the judgement
parameter
•
There is no overlap between the BPU and the lower tolerance envelope of the baseline data
•
Presented monitor strategy is capable to detect low flow at the EU6 emissions limit but there may be risk of early MIL activation
for a partially degraded system, at less than the type approval threshold, with components near to limit tolerances
2 November 2010
© Ricardo plc 2010
Page 95
RD.10/320201.4
Client Confidential
•
Plot below shows mean value and error bars based on the given tolerances for High Flow EGR
•
At the maximum EGR high flow fault tested, there is significant overlap between the Best Performing Unacceptable (BPU) and
Worst Performing Acceptable (WPA)
•
The maximum EGR high flow fault that could be tested without risk of clogging DPF was well below the proposed EU6 EOBD
thresholds for all emissions species
2 November 2010
© Ricardo plc 2010
Page 96
RD.10/320201.4
Client Confidential
4.9.2
4.9.2.1
Evaluation of Monitor IUMPR
Low Flow EGR Monitor
Ricardo IUMPR model was calibrated to monitor enable conditions similar to Manuf 3 EGR low flow monitor in the test data
•
Engine speed > 1000 rev/min
•
Accelerator pedal position > 1.5 %
•
Steady state operation : defined as follows
•
2 November 2010
© Ricardo plc 2010
–
engine speed rate of change within ±40 RPM/s
–
accelerator pedal rate of change < 5 %/s
Monitor enable conditions met for a continuous (un-interrupted) time of 5 seconds in order to make a judgement
Page 97
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 98
RD.10/320201.4
Client Confidential
The table below summarises EGR Low-Flow in-use performance ratio assessment from the above results.
CYCLE
Number of
Judgements
London
23
Paris
18
Stuttgart
8
Turin
12
Rural
19
Highway
46
The monitor was enabled several times over all the conditions evaluated. We would therefore expect this monitor to achieve minimum
ratio requirements robustly. Best monitoring robustness is achieved under highway driving conditions.
4.9.2.2
High Flow EGR Monitor
The following monitor enable conditions were programmed into the Ricardo IUMPR Model to analyse Manuf 3’s strategy:
•
Coolant temperature > 80 degC
•
In overrun
2 November 2010
© Ricardo plc 2010
–
Engine speed > 1100 rev/min
–
Accelerator pedal position < 1.5 %
Page 99
RD.10/320201.4
Client Confidential
•
Monitor enable conditions met for a continuous (un-interrupted) time of 5 seconds in order to make a judgment
The following histograms show the high flow EGR monitor enable profiles for Rural and Highway drive cycles:
Corresponding profiles for city driving are given on the following page for the 4 representative European cities.
2 November 2010
© Ricardo plc 2010
Page 100
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 101
RD.10/320201.4
Client Confidential
The table below summarises EGR High-Flow in-use performance ratio assessment from the above results.
CYCLE
Number of
Judgements
London
14
Paris
12
Stuttgart
10
Turin
11
Rural
10
Highway
14
The monitor was enabled several times over all the conditions evaluated. We would therefore expect this monitor to achieve minimum
ratio requirements robustly. Best monitoring robustness is achieved under highway driving conditions.
4.9.3
4.9.3.1
Conclusion
Low Flow EGR Monitor
•
2 November 2010
© Ricardo plc 2010
For Manuf 3 the proposed EU6 EOBD emissions threshold of NOx was exceeded with the low EGR flow system degraded with a
restrictor of less than 9 mm diameter.
Page 102
RD.10/320201.4
Client Confidential
•
4.9.3.2
A monitor judgment parameter using MAF, intake air temperature and pressure was shown to be capable of distinguishing the
baseline result (without a malfunction) from the proposed EU6 EOBD emissions threshold result over the NEDC test.
–
Analysis of likely tolerances on the judgement parameter suggests that the judgement parameter is capable of making a
robust distinction at the proposed EU6 EOBD threshold over a real fleet in real world conditions
–
There may be a risk of early MIL activation at close to the type approval NOx emissions level when component tolerances
are close to the limits
•
Analysis of likely monitor enable conditions over typical real world driving cycles suggests that the EGR low flow monitor is
capable of meeting the legislated minimum in-use performance ratio requirements
•
The proposed EU6 OBD limit of 140 mg/km NOx would be achievable for EGR monitoring using difference between desired and
actual air mass flow
High Flow EGR Monitor
•
The proposed EU6 EOBD emissions thresholds were not exceeded for any emissions species with the maximum level of EGR
high flow degradation evaluated.
–
Higher levels of EGR flow could not be tested due to risk of damage (clogging) of the DPF
•
A monitor judgement parameter using the MAF, intake air temperature and pressure was shown to be capable of distinguishing
the baseline result from the proposed EU6 EOBD emissions threshold result over the NEDC test
•
Analysis of likely tolerances on the judgement parameter suggests that the judgement parameter is not capable of making a
robust distinction between the level of degradation tested and the baseline system
•
2 November 2010
© Ricardo plc 2010
–
Higher levels of EGR degradation may be robustly detectable
–
High EGR flow may be indirectly monitored by detection of clogging in the DPF system, as this was the limiting factor
during the testing
Analysis of the likely monitor enabled conditions over typical real world driving cycles suggests that the Manuf 3 EGR high flow
monitor strategy is capable of meeting the legislated minimum in-use performance ratio requirements
Page 103
RD.10/320201.4
Client Confidential
Both EGR low and high flow monitors were capable of detecting the levels of degradation tested. The monitor strategies used have
been previously certified and are in production with this level of threshold detection.
For the Manuf 2 system (EGR with NSC and DPF after-treatment), monitoring of the EGR system for high and low flow to the proposed
EU6 thresholds is feasible with current monitoring strategies and technology
4.10 EGR Cooler / ByPass (Diesel)
The table below gives NEDC emission results.
The proposed EU6 EOBD emissions threshold for NOx was not exceeded even with an EGR cooler/bypass major failure
2 November 2010
© Ricardo plc 2010
Page 104
RD.10/320201.4
Client Confidential
The figure below is a zoom-in of the above graph to show the increase in emissions between the baseline (no malfunction) and the
totally failed cooler.
2 November 2010
© Ricardo plc 2010
Page 105
RD.10/320201.4
Client Confidential
4.10.1 Evaluation of OBD Monitor Strategy
Details of an EGR Cooler flow monitoring strategies were not provided and therefore monitor capabilities were not assessed. The results
presented are only an assessment of the impact of a major functional failure on NOx emissions on the specific vehicle tested by Manuf 3
4.10.2 Conclusion
•
The proposed EU6 EOBD emissions threshold for NOx was not exceeded even with an EGR cooler/bypass major failure
•
For the vehicle tested, monitoring of the EGR cooler would not be required to meet the proposed EU6 EOBD limits as emissions
do not exceed the OBD threshold
2 November 2010
© Ricardo plc 2010
Page 106
RD.10/320201.4
Client Confidential
•
Feasibility of a monitoring strategy to detect major functional failure of the EGR cooler has not been assessed as part of this
report
4.11 NSC/LNT Monitor (Diesel)
The table below gives NEDC emission results.
NOx emissions were very close to proposed EU6 EOBD threshold at 95 % degradation of NSC
CO emissions exceeded the proposed EOBD threshold with the 95 % degraded NSC. Both CO and NMHC emissions also showed
significant increases with degraded NSC.
2 November 2010
© Ricardo plc 2010
Page 107
RD.10/320201.4
Client Confidential
Emissions vs. 'level of degradation' (with hot starts)
Emissions vs. 'level of degradation'
600
Manuf 2
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
400
300
Manuf 2
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
500
NOx [mg/km]
500
NOx [mg/km]
600
200
100
400
300
200
100
0
0
20
40
60
Degradation [%]
80
0
0
100
20
Emissions vs. 'level of degradation'
NMHC [mg/km]
300
250
200
80
100
80
100
Emissions vs. 'level of degradation'
2000
Manuf 2
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
Manuf 2
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
1500
CO [mg/km]
350
40
60
Degradation [%]
150
100
1000
500
50
0
0
2 November 2010
© Ricardo plc 2010
20
40
60
Degradation [%]
80
100
0
0
20
40
60
Degradation [%]
Page 108
RD.10/320201.4
Client Confidential
4.11.1 Evaluation of OBD Monitor Strategy
Analysis of the monitor capability is based on Manuf 2 existing NSC monitoring algorithm. Details of the monitoring strategy provided by
Manuf 2 are given on the following pages. The basic functionality can be summarized as follows:
•
Regeneration using rich fuelling mixture entering the NSC
•
The NSC efficiency is calculated from the ratio between ‘slipped rich fuelling mixture’ and ‘supported rich fuelling mixture’. This
calculation is based on a measurement of upstream and downstream lambda values.
•
If the NSC becomes less efficient the ratio value increases
•
The value of this ratio is used as the judgement parameter of NSC efficiency
Calibration parameters were tuned to give the best monitor judgement possible with the available data
•
•
2 November 2010
© Ricardo plc 2010
Monitor enable conditions
–
DeNOx regeneration activated
–
‘Reageant consumption’ greater than a threshold
Monitor strategy
–
Evaluation of rSlip2Supply if monitoring is enabled
–
If rSlip2Supply exceeds a threshold rSlip2Supply, thres then an error counter is incremented
–
The threshold rSlip2Supply, thres depends on the exhaust gas temperature
Page 109
RD.10/320201.4
Client Confidential
Reagant consumption
Supplied reagant
Reagant slip
For the purpose of this report a judgement parameter is defined by the ratio value 3 s after the first starting regeneration
This is done to allow a consistent comparison between different tests, since the ratio value is not constant throughout regeneration and
the length of each regeneration event is not consistent across tests
The following figures show analysis using this monitor judgement parameter. The first figure shows results of the test, with 1 %
degradation
2 November 2010
© Ricardo plc 2010
Page 110
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 111
RD.10/320201.4
Client Confidential
The next figure shows results with 60% degradation
2 November 2010
© Ricardo plc 2010
Page 112
RD.10/320201.4
Client Confidential
And finally the figure below shows results of a component degraded by 95%
2 November 2010
© Ricardo plc 2010
Page 113
RD.10/320201.4
Client Confidential
Plot below shows calculated judgement parameter versus NOx emissions as NSC is degraded. As NSC is degraded there is a clear
trend and a significant separation between the result at the type approval threshold and the results obtained at the OBD threshold.
Judgement parameter vs. emissions
0.7
0.6
ratio r Slip2S ply [-]
0.5
0.4
0.3
NSC - 1 % degradation
NSC - 60 % degradation
NSC - 95 % degradation
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
0.2
0.1
0
0
20
40
60
80
100
120
140
160
NOx [mg/km]
2 November 2010
© Ricardo plc 2010
Page 114
RD.10/320201.4
Client Confidential
Plot below shows calculated judgement parameter versus CO emissions as NSC is degraded. As NSC is degraded there is a clear trend
and a significant separation between the result at the type approval threshold and the results obtained at the OBD threshold
Judgement parameter vs. emissions
0.7
0.6
ratio r Slip2S ply [-]
0.5
0.4
0.3
NSC - 1 % degradation
NSC - 60 % degradation
NSC - 95 % degradation
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
0.2
0.1
0
0
200
400
600
800
1000
1200
CO [mg/km]
2 November 2010
© Ricardo plc 2010
Page 115
RD.10/320201.4
Client Confidential
4.11.1.1
Monitor Robustness
•
Ricardo experience is a typical lambda sensor tolerance of up to 0.01 λ at stoichiometric and rich air/fuel ratios
•
Figure shows variations of judgement parameter when recalculated for upper and lower tolerance limits of both lambda sensors
•
Distinction is still possible between worst performing acceptable and best performing unacceptable parts after taking into account
sensor tolerances
•
The minimal estimated damage rate that could be detected robustly is 93 % and it corresponds to 128 mg/km NOx emissions
Judgement parameter vs. emissions
ratio r Slip2S ply [-]
0.8
0.6
0.4
NSC - 1 % degradation
NSC - 60 % degradation
NSC - 95 % degradation
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
0.2
0
0
20
40
60
80
100
120
140
160
NOx [mg/km]
2 November 2010
© Ricardo plc 2010
Page 116
RD.10/320201.4
Client Confidential
4.11.2 Evaluation of Monitor IUMPR
The following parametric information were used run the Ricardo IUMPR model
•
The NSC monitor is enabled only during NSC regeneration
•
The in-use performance model was modified to simulate NSC regeneration frequency and estimated NSC regeneration enable
conditions to match the NSC regeneration conditions encountered in the NEDC test data
•
The enable conditions for NSC regeneration and monitoring were:
–
900 rev/min < Engine speed < 3000 rev/min
–
Vehicle speed > 30 km/h
–
Torque up to just below full power, torque < 240 Nm
–
Dew detection of lambda downstream (lambda controlled DeNOx mode), enable time > 450 s
–
Gear > 1
–
Regeneration duration > 4 s
–
Time required for monitor judgement 3 s
The results here are exactly identical to those under Lambda Sensor monitor given in Section 4.2.2. Therefore the same conclusion can
be drawn regarding robustness of the monitor.
2 November 2010
© Ricardo plc 2010
Page 117
RD.10/320201.4
Client Confidential
4.11.3 Conclusion
•
The proposed EU6 EOBD threshold for NOx was reached (although the test results did not exceed the limit) with the NSC
degraded to 95 %
•
The proposed EU6 EOBD threshold for CO was exceeded with the NSC degraded to 95 %
•
The raw emissions are below the proposed Euro 6 OBD threshold (see page 106)
•
A monitor judgement parameter based on the NSC efficiency using the upstream and downstream lambda measurement is
capable of distinguishing the baseline result from the proposed EU6 EOBD emissions threshold result over the NEDC test
•
Analysis of likely tolerances on the judgement parameter suggests that the judgement parameter is capable of making a robust
distinction at the proposed EU6 EOBD threshold over a real fleet in real world conditions
•
Analysis of expected monitor enable conditions suggests that monitor enable conditions should be met over a wide range of
driving conditions and so the monitor should be capable to meet the minimum in-use performance ratio requirements
4.12 Oxidation Catalyst (Diesel)
Only NMHC and CO emissions are considered in this case. The table below gives NEDC emission results.
2 November 2010
© Ricardo plc 2010
Page 118
RD.10/320201.4
Client Confidential
The table below shows NMHC emissions versus degradation level
4.12.1 Evaluation of OBD Monitor Strategy
Analysis of the monitor capability is based on Manuf 3 existing DOC monitoring algorithm. The basic functionality of the monitoring
strategy provided by Manuf 3 is summarized below.
•
DOC provides oxidation of HC’s during normal operation and is used to provide high temperature feed-gas to the DPF during
regeneration.
•
Monitor judgement is based on a comparison of temperature sensors at DOC inlet and outlet during DPF regeneration, where a
significant temperature rise is expected at the DOC outlet.
2 November 2010
© Ricardo plc 2010
Page 119
RD.10/320201.4
Client Confidential
A functional diagram of the DOC monitor strategy is given below
2 November 2010
© Ricardo plc 2010
Page 120
RD.10/320201.4
Client Confidential
An example showing the monitor output during a regeneration of the DPF is illustrated in the figure below.
2 November 2010
© Ricardo plc 2010
Page 121
RD.10/320201.4
Client Confidential
The next 2 pages show examples of typical monitor results operating over an NEDC, first with a normal and then with a failed catalyst
2 November 2010
© Ricardo plc 2010
Page 122
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 123
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 124
RD.10/320201.4
Client Confidential
The figure below demonstrates the monitor capability over NEDC cycle.
2 November 2010
© Ricardo plc 2010
Page 125
RD.10/320201.4
Client Confidential
4.12.1.1
Monitor Robustness
The following tolerance data was provided by Manuf 3 for the DOC monitor input parameters
System
Tolerance
(estimates)
Temperature Sensor (Ups/Dns of DOC)
5%
Air Massflow Sensor
7%
Fuel Injection Mass
10%
Unburnt Fuel in Exhaust Gas
20%
The tolerances were applied as follows:
•
•
Measured heat calculation (numerator)
–
Air flow sensor
–
Temperature sensor (upstream of DOC)
–
Temperature sensor (downstream of DOC)
Simulated heat calculation (denominator)
–
Fuel injection mass
–
Unburned fuel
Since the monitor is using temperature difference, the absolute temperature sensor tolerance for each sensor was calculated from the
normal temperature during regeneration
2 November 2010
© Ricardo plc 2010
Page 126
RD.10/320201.4
Client Confidential
•
The charts below show the results of the Ricardo tolerance analysis compared to the Manuf 3 tolerance analysis, showing the
tolerance range of the judgement parameter compared to the emissions results
•
The results are not identical, however are very similar and both confirm that there is sufficient separation in the judgement
parameter between the normal and degraded DOC system
•
Differences are probably due to the estimation of the absolute temperature sensor tolerance being slightly different
2 November 2010
© Ricardo plc 2010
Page 127
RD.10/320201.4
Client Confidential
4.12.2 Evaluation of Monitor IUMPR
In order to assess capability of any OBD monitoring strategy, it is necessary to consider whether enable conditions required to make a
judgement will be met with sufficient frequency in the typical range of real world driving
•
DOC monitoring only takes place during DPF regeneration
In case of DOC, the denominator may wait 800 km in between incrementing
•
To meet the target minimum in-use performance ratio of 0.336, monitoring is needed only once every 2400 km
Therefore, meeting the minimum in-use performance ratio should be possible provided that:
•
The frequency of needing to regenerate the DPF is not very low
•
There is a good chance for monitoring to be completed during each regeneration
–
Regeneration is not easily interrupted
–
Monitoring is enabled in most regeneration conditions
The monitor appears to complete a judgement during the 3x UDC parts of NEDC test, when vehicle speed is low and stationary
•
This gives good confidence that monitoring complete frequently in real world use
4.12.3 Conclusion
•
The proposed EU6 EOBD emission threshold for NMHC was not exceeded with the total removal of the DOC
•
A monitor judgement using the temperature sensors at DOC inlet and outlet during DPF regeneration was capable of
distinguishing the baseline result from the total failure result over the NEDC test for the vehicle tested
•
Analysis of likely tolerances suggests that the monitor would be capable of making a robust distinction between the baseline
failure and the total failure
•
The proposed EU6 OBD limit of 140 mg/km NMHC was achievable for DOC monitoring for the vehicle tested here, however:
2 November 2010
© Ricardo plc 2010
Page 128
RD.10/320201.4
Client Confidential
•
–
This corresponded to total failure of the DOC because tailpipe emissions were below 140 mg/km in this condition
–
The spread of emissions results suggests that a partially failed DOC could not be robustly detected for this vehicle
–
Data from vehicles with different after-treatment layouts and engine out emissions would need to be assessed, at DOC
degradation levels in between normal and total failure in order to confirm the feasibility of a 140 mg/km limit for all
vehicles
Analysis of the likely monitor enable conditions over typical real world driving cycles suggests that the DOC monitor is capable of
meeting the legislated minimum in-use performance ratio requirements
4.13 Particulate Filter (Diesel)
The table and the two graphs below give NEDC emission results obtained by Manufacturer 3
The figures below show PM and PN increase due to DPF degradation
2 November 2010
© Ricardo plc 2010
Page 129
RD.10/320201.4
Client Confidential
The table and figures below give NEDC emission results obtained by Manufacturer 4
2 November 2010
© Ricardo plc 2010
Page 130
RD.10/320201.4
Client Confidential
Results obtained by Manufacturer 5 are given in the table and figures below. Emission test results are shown for NEDC test cycles from
both cold and hot starts
2 November 2010
© Ricardo plc 2010
Page 131
RD.10/320201.4
Client Confidential
Note that NOx emissions in the above table are above the Euro 6 threshold for all tests. This is because the engine under test is
certified to Euro 4 and so NOx is not considered in this analysis.
2 November 2010
© Ricardo plc 2010
Page 132
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 133
RD.10/320201.4
Client Confidential
4.13.1 Evaluation of Manuf 3 DPF Monitor Strategy
The basic functionality of the monitoring strategy provided by Manuf 3 is summarized below.
•
Differential pressure measured directly by the ECU using a sensor connected immediately upstream and downstream of the DPF
An example showing the monitor output is illustrated in the figure below.
2 November 2010
© Ricardo plc 2010
Page 134
RD.10/320201.4
Client Confidential
The set of figures on the next 4 pages illustrate the operation of the monitor functionality over an NEDC cycle.
2 November 2010
© Ricardo plc 2010
Page 135
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 136
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 137
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 138
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 139
RD.10/320201.4
Client Confidential
The OBD judgment parameter defined as the ratio of measured to simulated values of soot is shown in the figure below vs. PM
emissions.
2 November 2010
© Ricardo plc 2010
Page 140
RD.10/320201.4
Client Confidential
4.13.1.1
Monitor Robustness
The following tolerances were provided by Manuf 3 for the inputs into the monitoring strategy
System
Tolerances
Differential Pressure Sensor
<5%: ±11-17 hPa depending on sensor type
(@ 10 – 85 °C, 0-750 hPa) partially
compensated by drift adaption
Exhaust Gas Volume Flow Model
10% (estimation. Involved components:
HFM, T5, T6, injection mass)
Engine-out Particulate Matter Model
25% (estimation)
Unrecognised CRT effects
<5%
Manuf 3 approach: The Gaussian failure calculation for failures with statistical distribution was applied as follows:
2 November 2010
© Ricardo plc 2010
Page 141
RD.10/320201.4
Client Confidential
The charts below show the tolerance impact on the judgement parameter using the data provided by Manuf 3
•
Left plot:
Absolute tolerances
•
Right plot: Gaussian statistical analysis by Manuf 3
For the purpose of identifying the best achievable OBD threshold, the analysis will continue using the Gaussian statistical method
2 November 2010
© Ricardo plc 2010
Page 142
RD.10/320201.4
Client Confidential
The charts below show Gaussian tolerance analysis for the monitor judgement results versus PM and PN emissions. The following
labels are used
BPU = Best Performing Unacceptable
WPA = Worst Performing Acceptable
Robust monitoring can be achieved where there is no overlap between BPU and WPA. Based on this analysis the graphs show
monitoring capability to detect particulate emissions levels for this vehicle of:
Particulate Matter (PM):
33.4 mg/km
Particulate Number (PN): 41.3x1012 parts/km
which is equivalent to a particulate reduction rate of:
Particulate Matter (PM):
2 November 2010
© Ricardo plc 2010
33.3 %
Particulate Number (PN): 18.2 %
Page 143
RD.10/320201.4
Client Confidential
4.13.2 Evaluation of Manuf 4 & Manuf 5 DPF Monitor Strategy
Monitor strategy assessed by both Manuf 4 and Manuf 5 were based on installation of a Particulate sensor located downstream of the
DPF. Both manufacturers used prototype resistive-type Particulate Matter sensor technology in the recommended position in the
exhaust for homogeneous soot dispersion.
Sensor current increases as particulate matter accumulates on the sensor electrodes
The particulate sensor is still under development and so a mature monitoring strategy is not available. Any monitor judgement of the
soot level downstream of the DPF (and hence failure of the DPF) would be based on the sensor response time:
•
•
Time taken for the sensor current to reach regeneration threshold
–
After every engine start the sensor must first reach it’s dew point and then it has to be regenerated (as preconditioning)
before a measurement can be made
–
The sensor is then regenerated by an internal heating element to burn off the accumulated particulate matter. After the
regeneration, the sensor is ready to accumulate particulate matter and possibly make another judgement
The “response time” of the sensor decreases as DPF leakage increases
Key Particulate Matter (PM) Sensor Characteristics are illustrated on the figure below with respect to a cold start NEDC.
2 November 2010
© Ricardo plc 2010
Page 144
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 145
RD.10/320201.4
Client Confidential
The key criteria for OBD monitoring is that soot accumulation on the sensor reaches the regeneration threshold at least once within the
NEDC test
•
This must include the time for the sensor to reach it’s dew point and complete the preconditioning regeneration as well as the
actual sensor response time
•
Ideally, two soot accumulation and regeneration events would be preferred within the NEDC test, to prevent false MIL activation
Data was provided from 2 sensor locations in the exhaust system as part of ongoing investigations by Manuf 4 to find the best position.
The two locations are indicated on the schematic below.
•
Location S1 - Just after DPF
•
Location S2 - Downstream of SCR catalyst
2 November 2010
© Ricardo plc 2010
Page 146
RD.10/320201.4
Client Confidential
The figures below shows sensor regeneration and response times vs Particulate Mass (PM) Emissions for the two sensor locations
indicated above.
Similar results for Particulate Number (PN) emissions are shown for the NEDC over the same sensor locations.
2 November 2010
© Ricardo plc 2010
Page 147
RD.10/320201.4
Client Confidential
The test vehicle used by Manufacturer 5 was EU4 specification and therefore did not have NOx after-treatment equipment installed.
Therefore the results presented below from Manufacturer 5 are equivalent to location S1 Manuf 4’s results above.
2 November 2010
© Ricardo plc 2010
Page 148
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 149
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 150
RD.10/320201.4
Client Confidential
Based on the results from Manuf 5, the only fault level that was capable of being detected during the NEDC cycle from a cold start was
the empty DPF can
•
This may not be representative of a leaking DPF with similar PM emissions, faster warm up to sensor dew point may be due to
lack of DPF substrate thermal inertia
When started with a hot engine, a regeneration event was possible with all levels of degraded DPF tested
•
A number of the hot start tests achieved 2 regeneration events within the test cycle
The limiting factor appears to be the time taken for the sensor to reach it’s dew point when the engine is started from cold
•
A sensor location further upstream in the exhaust system would benefit, however, the position in this test was as per the sensor
manufacturer’s recommendation for homogeneous mixing
•
The capability of the sensor is very dependant on the specific engine/vehicle on test, e.g. the thermal inertia of other exhaust
after-treatment components
–
The test vehicle here was EU4 specification and had no NOx after-treatment that would likely delay the dew point further
The dew point times achieved in this set of tests appear longer than Ricardo would expect
4.13.2.1
Monitor Robustness
Additional testing (data not included in this report) was carried out by Manuf 4 to determine robustness of PM sensor response time to
exhaust flow distribution
•
Comparing locations S1 and S2
•
Comparing results with the same % failure of DPF but with plugs removed from different locations across the face
Based on that analysis, the following conclusions were made:
2 November 2010
© Ricardo plc 2010
Page 151
RD.10/320201.4
Client Confidential
•
Location S1 is most favourable for regeneration time, due to early dew point detection
•
Monitor based on sensor location S1 would not be robust because:
•
–
Results are inconsistent depending on the location of the removed plugs on the DPF face
–
This may cause either false MIL or false pass due to poor soot dispersion
Manuf 4 recommendation is that a position further away from the DPF with good dispersion of soot, i.e. S2, is necessary.
Based on the results from location S2, a regeneration during the NEDC cycle was first possible with 12 % DPF failure, equivalent to:
•
12.3 mg/km Particulate Matter (PM): 1.4 times the proposed EU6 EOBD limit
•
38.3x1012 /km Particulate Number (PN): > 30 times the proposed limit
In order to improve robustness the monitor result should be based on 2 successive regenerations. Using sensor location S2, this was
only achieved on the NEDC with a DPF failure level of 100 % (i.e. empty DPF can)
•
It does not seem likely that robust monitoring will be possible to an adequate emissions sensitivity if 2 regenerations are required
in one NEDC
•
Ricardo recommendation would be to use a single regeneration and then make best use of the pre-conditioning cycles allowed in
the legislated test procedure
–
Pending code set on 1st and 2nd cycles (2 pre-conditioning cycles allowed)
–
MIL activated on 3rd cycle (actual test cycle)
Data provided by the particulate sensor supplier shows results of repeatability and durability testing of the sensor (on testbench only):
•
Typical repeatability of single sensor of ±3 % response time
•
29 sensors aged to 3000 hrs showed response time calculations varied by ±25 %
The charts below show the effective regeneration times using sensor location S2 with error bars reflecting regeneration time tolerance of
±126 seconds
•
2 November 2010
© Ricardo plc 2010
±68 secs equivalent to ±25 % tolerance of the average response time
Page 152
RD.10/320201.4
Client Confidential
•
Additional ±58 secs for the tolerance of sensor dew point time during the tests
Based on these results, the following observations are made:
•
Best performing ‘malfunctioning’ DPF may not be detected at 12 % DPF failure
•
Best achievable monitor threshold would be approximately 14 % DPF failure, at which point estimated emissions would be:
–
PM = 13.7 mg/km
–
PN = 43.4x1012 parts/km
The analysis contained in this report only considers sensor response time during NEDC testing.
•
2 November 2010
© Ricardo plc 2010
PM sensor response time will depend on engine out particulates, hence engine speed and load
Page 153
RD.10/320201.4
Client Confidential
•
Therefore a monitoring strategy must implement a variable response time threshold
–
Necessary upper limit to give a test pass result for the monitor
–
Will have to be a function of the speed/load ‘history’ since the last PM sensor regeneration
–
This may lead to additional real world tolerances not yet considered
Since the test data provided by manufacturer 5 do not show any regeneration events possible within the NEDC test cycle from cold
start, a proper tolerance assessment of the robustness of any potential monitor strategy is not possible
Accurate prediction of the sensor response times are difficult because they will depend on the speed/load conditions of the engine while
the soot accumulation is in progress
If a regeneration is made just before the end of the NEDC, the soot accumulation will mainly be during the highest speed part of the
cycle
•
•
The best indication of sensor response time in this part of the cycle is the hot NEDC data for 75 % failed DPF:
–
Average response time = 327 s and 3σ = 9 %
–
Equivalent cold NEDC PM emissions were 13.2 mg/km average
Extrapolating for PM emissions at the proposed threshold of 9 mg/km this implies a worst case (mean + 3σ) sensor response
time of 523 seconds
–
So for regeneration to occur before the final deceleration of the NEDC, the sensor dew point must always be achieved
within the first 600 seconds of the cycle
With the sensor dew point not being reached until later than 1000 seconds from cold start, as in these test, a monitoring strategy using
this prototype soot sensor is not feasible. If some development of the system was possible to improve the exhaust warm up and achieve
a sensor dew point at 800 seconds, this would imply:
•
An average sensor response time of 298 seconds, after applying a 3σ tolerance
•
Extrapolating from the 75 % failed DPF data, achievable OBD thresholds of:
–
2 November 2010
© Ricardo plc 2010
14.5 mg/km for PM
Page 154
RD.10/320201.4
Client Confidential
–
84.8x1012 parts/km PN
The analysis contained in this report only considers sensor response in the NEDC
•
Real world PM sensor response time will depend on engine out particulates, hence engine speed and load
•
Therefore a monitoring strategy must implement a variable response time threshold
–
Necessary upper limit to give a test pass result for the monitor
–
Will have to be a function of the speed/load ‘history’ since the last PM sensor regeneration
–
This may lead to additional real world tolerances not yet considered
4.13.3 Evaluation of Monitor IUMPR
Manuf 4 & 5 monitoring strategy will essentially operate under all conditions after the sensor dew point is reached after each engine
start. The likely difficulty with real world in-use monitor performance ratio will be the time taken to run the monitor:
•
Monitor takes around 1000 seconds to complete a judgement on the NEDC cycle
–
•
This could be similar for vehicle warm up at slow driving conditions (same temperature)
The performance ratio denominator may increment after 600 seconds of driving
–
It may be possible for the denominator to increment before the monitor can complete
The concern above is mitigated by the following:
•
Denominator for DPF monitoring is allowed to wait 800 km driving in between incrementing
–
•
2 November 2010
© Ricardo plc 2010
Unlikely that a drive cycle longer than 1000 seconds will not have occurred in that time
It seems unlikely that drive cycles of this specific combination of speed/load and duration to be frequent for a statistically
significant number of drivers
Page 155
RD.10/320201.4
Client Confidential
4.13.4 Conclusion
•
The proposed EU6 EOBD emissions threshold for PM was exceeded with approximately 8 % DPF degradation
•
The threshold for PN was exceeded with the DPF degradation exceeding 0.14 % (estimated by linear interpolation)
•
There was a measured difference in monitor judgement parameter between the baseline test and that at the proposed EU6
EOBD PM
•
Analysis of likely tolerances on the judgement parameter suggests that the judgement parameter is not capable of making a
robust distinction at the proposed EU6 EOBD threshold over a real fleet in real world conditions
•
The table below summarises the test results obtained by all 3 manufacturers who carried out tests on DPF, showing the best
achievable EOBD thresholds for monitoring of the DPF.
•
2 November 2010
© Ricardo plc 2010
PM
(mg/km)
PN
12
(x10 parts/km)
Comments
9
1.2
←Proposed OTL
Manuf 3
33.4
41.3
Using enhanced ∆p strategy
Manuf 4
13.7
43.4
Using resistive PM sensor
Manuf 5
14.5
85
Using resistive PM sensor
Analysis of the likely monitor enabled conditions over typical real world driving cycles suggests that the DPF monitor is capable
of meeting the legislated minimum in-use performance ratio requirements
Page 156
RD.10/320201.4
Client Confidential
4.14 SCR Monitor (Diesel)
The table below gives NEDC emission results. NOx emissions were very close to EU6 threshold with 10 % or lower SCR dosing rate.
Emissions vs. 'level of degradation'
Manuf 3 - 1st iteration
EU6 TA
EU6 prop OBD
EU6 int OBD
EU5 OBD
Manuf 3 - 2nd iteration
NOx [mg/km]
500
400
300
200
100
0
Base
50 % dosing
10 % dosing
Degradation
0 % dosing
4.14.1 Evaluation of OBD Monitor Strategy
Analysis of the monitor capability is based on Manuf 3 existing SCR monitoring algorithm. The basic functionality of the monitoring
strategy provided by Manuf 3 is summarized below.
•
SCR efficiency monitor is based on the monitoring of high tailpipe NOx caused by poor SCR conversion efficiency.
•
The efficiency is monitored by a single NOx sensor downstream of the SCR catalyst, compared to modelled engine out NOx
2 November 2010
© Ricardo plc 2010
Page 157
RD.10/320201.4
Client Confidential
A functional diagram of the SCR monitor strategy is given below
2 November 2010
© Ricardo plc 2010
Page 158
RD.10/320201.4
Client Confidential
The figure below shows a plot of the Judgment variable vs. NOx
2 November 2010
© Ricardo plc 2010
Page 159
RD.10/320201.4
Client Confidential
•
Results are plotted from tests with cold and hot engine start
•
Judgement results for hot tests are plotted against the NOx measured with the equivalent level of degradation from the cold test
2 November 2010
© Ricardo plc 2010
Page 160
RD.10/320201.4
Client Confidential
4.14.1.1
Monitor Robustness
The following tolerances were provided by Manuf 3 for the inputs into the monitoring strategy
System
Tolerances
NOx Sensor
15 ppm (c<100 ppm), 15% (c>100 ppm), aged
Engine-out NOx Model
30% (Estimation)
Tolerances were applied to the judgement efficiency (ratio) calculation as follows:
•
±15 % tolerance to the numerator (measured value)
•
±30 % tolerance to the denominator (modelled value)
Worst case tolerances were considered when either the numerator is at its upper limit and the denominator is at its lower limit, or the
numerator at the lower limit and denominator at the upper limit.
The charts below show tolerance range of the judgement parameter compared to the emissions results, comparing Ricardo analysis
with Manuf 3 analysis.
The results are very similar and both confirm that there is sufficient separation in the judgement parameter between the normal and
threshold degraded SCR system
The differences are because:
•
2 November 2010
© Ricardo plc 2010
Ricardo analysis uses 15 %, rather than 15 ppm NOx sensor tolerance at low concentrations, and so underestimates the
tolerance for the baseline result. Using 15 ppm at low NOx concentrations would only affect baseline result and would make no
difference to conclusion.
Page 161
RD.10/320201.4
Client Confidential
•
The Manuf 3 analysis uses one set of test results while the Ricardo analysis is based on the average of all results
Engine-out NOx emissions vary in relation to the engine concept, the vehicle weight, and drive resistance. The vehicle tested in this
study has quite low engine out NOx levels and so the proposed EOBD threshold appears to be achievable.
With a rough graphical interpolation, the Best Unacceptable SCR catalyst, whose tolerance region would not overlay with the Worst
Acceptable catalyst (at Type Approval Limits) would be 50 % + 24.4 % about 75 % damaged.
2 November 2010
© Ricardo plc 2010
Page 162
RD.10/320201.4
Client Confidential
Therefore, a simple estimation of the robust monitoring threshold can be calculated:
(engine out emissions – EU6 standard) * 0.75 + EU6 standard
To predict a realistic forecast of EU6 engine out emissions, all diesel participants of the ACEA EU6 study were requested to provide
their expected range.
2 November 2010
© Ricardo plc 2010
Page 163
RD.10/320201.4
Client Confidential
•
The table below shows the range of engine out NOx emissions of manufacturers taking part in the study, along with the
respective predictions of an achievable NOx OBD threshold using the calculation above
•
This simple prediction shows that a NOx OBD threshold that can be robustly achieved by the whole range of EU6 diesel vehicles
has to be higher than the proposed 140 mg/km
–
•
For some vehicles, even the interim EU6 NOx OBD threshold of 240 mg/km may not be robust
This forecast is based on a very simple analysis
–
A more accurate prediction of the monitor capability for higher engine out levels of NOx is very difficult because of
assumptions that must be made about the overall SCR system performance and the NOx emissions at the time that
monitoring is active
–
It is recommended that further testing would be required with a vehicle giving higher engine out NOx to confirm the
accuracy of this prediction before considering a further reduction to the OBD NOx threshold
4.14.2 Evaluation of Monitor IUMPR
Ricardo model was calibrated over the NEDC test cycle with enable conditions to match Manuf 3’s enable conditions in the test data:
•
Engine speed > 1500 rev/min
•
Engine temperature > 80 degC
•
Engine torque: (note: a full load torque maximum is 270 Nm)
2 November 2010
© Ricardo plc 2010
Page 164
RD.10/320201.4
Client Confidential
•
–
> 62 Nm
–
> 70 Nm
Monitor enable conditions met for a cumulative time of 60 s in order to make a judgement
The analysis was repeated with two threshold engine torque limits, as shown above, to assess the sensitivity during the city cycles
where engine load is generally lower. The results below show the output using the 62 Nm torque threshold:
2 November 2010
© Ricardo plc 2010
Page 165
RD.10/320201.4
Client Confidential
2 November 2010
© Ricardo plc 2010
Page 166
RD.10/320201.4
Client Confidential
The table below summarises the in-use performance ratio assessment
CYCLE
Number of Judgements
62 Nm
70 Nm
London
1
1
Paris
1
0
Stuttgart
1
0
Turin
0
0
Rural
3
3
Highway
8
7
The above analysis suggests that there is a high risk of the monitor not achieving minimum ratio requirements robustly under all
operating conditions.
•
Monitor enable conditions must be matched to the SCR system dosing enable conditions
•
This means that sufficient speed and load are required for operating temperature of the SCR catalyst
•
Monitor enablement and final in-use performance will be dependent on the specific vehicle and it’s SCR control system
calibration
2 November 2010
© Ricardo plc 2010
Page 167
RD.10/320201.4
Client Confidential
4.14.3 Conclusion
•
Emissions of NOx were at or very close to the proposed EU6 EOBD threshold with the SCR system degraded to 10 % or less of
the normal urea dosing rate
•
A monitor judgement parameter using a NOx sensor downstream of the SCR catalyst was capable of distinguishing the baseline
result from the proposed EU6 EOBD emissions threshold result over the NEDC test for the vehicle tested
•
Analysis of likely tolerances on the judgement parameter for this vehicle suggests that the monitor would make a robust
distinction at the proposed EU6 EOBD threshold of 140 mg/km NOx, however:
•
2 November 2010
© Ricardo plc 2010
–
This corresponds to near total failure of the SCR system because the basic engine out emissions from the vehicle tested
are low compared to the proposed EOBD threshold
–
Analysis of the best achievable EOBD threshold for the range of engine out NOx levels for the manufacturers involved in
this study suggests that the best achievable threshold may need to be as high as 280 mg/km in some cases
–
Further testing with several representative EU6 vehicles with higher engine out NOx is proposed, before considering a
lower EOBD NOx threshold
Analysis of the likely monitor enable conditions over typical real world driving cycles suggests that there may be a risk of limited
monitor enablement in some low speed/load driving conditions.
Page 168
RD.10/320201.4
Client Confidential
5.
SUMMARY
The table below summarises results obtained for each of the components evaluated. The first column (sect) gives the section number
within the document where results for this component are discussed.
The IUMPR column is used to indicate whether the likely monitor enable conditions over typical real world driving cycles at normal
ambient conditions will achieve minimum ratio requirements robustly under all operating conditions and, where indicated in the table
below, in respect of the best achievable thresholds. This is only done where data was provided to make this analysis possible.
In the case of gasoline engines, although analysis of the likely monitor enable conditions over typical real world driving cycles has not
been carried out, nevertheless these monitors have been engineered for the California ULEV II emission standards and are fully
compliant with the associated OBD regulations including minimum IUMPR requirements. However, this is not the case for compressionignition engines
Table key for Sections 5.1 and 5.2:
none
n/a
Data not available
Pollutant is not sensitive or degradation is not significant relative to the OBD threshold
An emissions threshold is not applicable because the pollutant was not sensitive to the fault
EU6
TFF
The proposed EU6 EOBD threshold is achievable
Total Functional Failure
2 November 2010
© Ricardo plc 2010
Page 169
RD.10/320201.4
Client Confidential
Sect
Gasoline Results
Component (Fuel)
Monitor Evaluated in this Report
on NEDC
Achievable Threshold on NEDC (mg/km)
12
except PN (x10 /km)
Maximum Observed Degradation
12
(mg/km) except PN (x10 /km)
CO
NM
HC
NOx
PM
PN
CO
NM
HC
NOx
PM
PN
IUMPR
5.1
4.1
Linear O2 Sensors
(upstream)
Inducing fuelling oscillation and
measuring sensor response
282
none
47.6
2.69
-
EU6
n/a
EU6
EU6
-
-
4.3
Lambda Sensors
(downstream)
Evaluating sensor response during
rich to lean transitions when fuel cut
is activated
none
none
none
none
-
n/a
n/a
n/a
n/a
-
-
4.4
3W Catalytic
Converter
Cycling fuelling rich and lean to
determine oxygen storage
978
277
136
none
-
Not
regulated
277*
136*
Not
regulated
Not
regulated
-
4.5
Misfire Monitor
Crankshaft Speed Fluctuation (CSF)
method
956
216
64
3.6
none
EU6
216
EU6
n/a
n/a
-
4.6
Fuel System Monitor
Analysis of long-term fuel
adaptations
1764
90
61
3.9
none
1764
EU6
EU6
EU6
n/a
-
4.7
VVT System Monitor
Direct measurement of cam position
error
1298
177
46
none
-
EU6
-
EU6
n/a
-
-
4.8
MAF Sensor Monitor
Measured vs Modelled Airflow
none**
none**
none**
none**
-
n/a
n/a
n/a
n/a
-
-
* NOx and NMHC were exceeded for tests carried out with degraded catalysts. A less aggressively aged catalyst (giving NOx and NMHC just below the proposed EU6 OBD
threshold) is required in order to make a definitive statement about the feasibility of monitoring techniques for EU6 OBD tests
** Lambda Feedback is assumed to compensate for the MAF sensor having a rich bias. This makes the fault insensitive to small deviations in MAF sensor reading
Regarding IUMPR, refer to explanation in Section 5 above
2 November 2010
© Ricardo plc 2010
Page 170
RD.10/320201.4
Client Confidential
Sect
Diesel Results
Component (Fuel)
Monitor Evaluated in this Report
on NEDC
Maximum Observed Degradation
12
(mg/km) except PN (x10 /km)
Achievable Threshold on NEDC
12
(mg/km) except PN (x10 /km)
CO
NM
HC
NOx
PM
PN
CO
NM
HC
NOx
PM
PN
IUMPR
5.2
4.2
Lambda Sensors
(linear)
Comparing sensor delay times
against threshold values
174
none
56.2
2
0.0014
EU6
n/a
n/a
n/a
n/a
4.9
Low Flow EGR
difference between desired and
actual air mass flow
none
none
1146
-
-
n/a
n/a
EU6
n/a
n/a
4.9
High Flow EGR
using MAF, intake air temperature
and pressure
163
23.5
none
-
-
n/a
n/a
n/a
n/a
n/a
4.10
EGR Cooler / ByPass
No monitor evaluated
none
none
none
-
-
-
-
-
-
-
-
4.11
NSC/LNT Monitor
using upstream and downstream
lambda measurement
1071
102
133
2.5
none
TFF
EU6
TFF§
n/a
n/a
-
4.12
Oxidation Catalyst
using temperature sensors
none
none
none
none
none
n/a
n/a
n/a
n/a
n/a
4.13
Particulate Filter
Differential pressure across DPF
-
-
-
58.8
53
n/a
n/a
n/a
33.4
41
none
none
none
50.3
103
n/a
n/a
n/a
14.5
85
-
-
136
-
-
n/a
n/a
TFF§
n/a
n/a
Prototype resistive-type PM
sensor
4.14
SCR Monitor
By NOx sensor downstream of
SCR catalyst, compared to
modelled engine out NOx
§ Note that this engine’s engine out emissions are lower than the OBD threshold and therefore a TFF is specified.
2 November 2010
© Ricardo plc 2010
Page 171
RD.10/320201.4
Client Confidential
6.
CONCLUSIONS
The impact of reduced OBD thresholds or intrusive monitoring techniques on CO2 emissions are not examined in this report.
Durability evaluation of sensors was not part of this study but remains a significant aspect to consider for the application and integration
of sensors in vehicle emission control systems, especially in relation to real-driving performance and capability with different biofuel
blends.
6.1
Gasoline
The main points that need to be highlighted for Gasoline engines are as follows:
1. OBD Monitor thresholds were exceeded for NOx and NMHC with the degraded catalysts used. Work is required with less
aggressively aged catalysts in order to make a definitive statement about the feasibility of the monitoring techniques to detect a
threshold component.
2. Misfire detection using Crankshaft Speed Fluctuation (CSF) method successfully detected a 6 % misfire, however in some tests this
caused emissions above the proposed EU6 thresholds. Further investigation would be required with revised monitor thresholds and
a lower misfire rate to confirm that detection at the proposed threshold level would not result in false misfire detection.
3. VVT System Monitoring successfully detected a Total Functional Failure (TFF), however emissions exceeded the proposed EU6
EOBD thresholds. Further investigation would be required with revised monitor thresholds and partial VVT failure to confirm that
detection at the proposed threshold level would not result in false fault detection.
4. Although PN and PM measurements were taken, in each case a specific trend was not obvious and the proposed OBD and type
approval thresholds were not exceeded in any of the test measurements made.
6.2
Diesel
With regard to Diesel vehicle emissions, the following conclusions are drawn:
2 November 2010
© Ricardo plc 2010
Page 172
RD.10/320201.4
Client Confidential
1. The EGR low flow monitor was able to distinguish the baseline result (without a malfunction) from a failure at the proposed EU6
EOBD emissions level. However, to reduce the risk of false failure detection with partial degradation and emissions within the type
approval emission limit, more separation is required between the type approval and EOBD thresholds.
2. None of the EGR high flow faults resulted in significant increase in emissions due to the DPF effectively removing any additional PM.
3. Total EGR Cooler / By-Pass failure did not cause the proposed EU6 EOBD thresholds to be exceeded.
4. The NOx threshold achieved on the vehicle tested for NSC/LNT monitor was approximately the proposed EU6 threshold. However,
on the application tested this represented a large scale failure of the NSC/LNT because of the relatively low engine out NOx level.
Additional work is required to confirm a threshold that can be robustly detected by all engines.
5. Emissions for DOC failures examined were below the proposed OBD thresholds. However, this corresponded to total failure of the
DOC because tailpipe emissions were below 140 mg/km in this condition. The spread of emissions results suggests that a partially
failed DOC could not be robustly detected for this vehicle.
6. The best achievable PM threshold for DPF monitoring based on differential pressure across the DPF was over 3 times the proposed
EU6 threshold.
7. The best achievable PN threshold for DPF monitoring based on differential pressure across the DPF was over 30 times the
proposed EU6 threshold.
8. The best achievable PM threshold for DPF monitoring based on resistive soot sensor was over 1.6 times the proposed EU6
threshold.
9. The best achievable PN threshold for DPF monitoring based on resistive soot sensor was over 70 times the proposed EU6
threshold.
10. The NOx threshold achieved on the vehicle tested for SCR monitor was approximately the proposed EU6 threshold. However, on
the application tested this represented a large scale failure of the SCR system because of the relatively low engine out NOx level.
Additional work is required to confirm a threshold that can be robustly detected by all engines.
2 November 2010
© Ricardo plc 2010
Page 173