Catalog Number Notes FEATURES & SPECIFICATIONS INTENDED USE — For entrances, stairwells, corridors and other pedestrian areas. Certain airborne contaminants can diminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses. Type Small Vandal-Resistant Wall-Pack CONSTRUCTION — Housing is white polyester powder painted steel backplate on which electrical components are mounted. Cast housing (PE option) is rugged, lightweight cast aluminum with dark bronze polyester powder finish. Electrical components are mounted to the cast housing for maximum heat dissipation. Closed-cell gasketing between the backplate and the mounting surface seals the junction. Stainless steel external hardware includes slotted and tamper-proof Torx-head fasteners. TWL Finish: Dark bronze (DDB) corrosion-resistant polyester powder. OPTICS — Front cover/refractor is injection-molded, one-piece, UV-stabilized polycarbonate. The optical system is sealed and gasketed to inhibit the entrance of outside contaminants. TRIPLE-TUBE FLUORESCENT 26W, 32W, 42W 6' to 12' Mounting ELECTRICAL — Multi-volt (120-277) high power factor, solid state, electronic ballast is standard. (Requires 4-pin lamp.) Electronic components are mounted to the housing, providing easy access during servicing. Four-pin, positive-latch thermoplastic socket. Requires four-pin lamp. Four-pin tri-tube lamp included. INSTALLATION — Designed to be mounted to a 4" round or 4" square outlet box. Surface conduit mount requires exterior collar accessory (standard version). Cast housing (PE option) has 3/4" threaded hub for surface conduit. LISTINGS — UL Listed for wet locations. Listed and labeled to comply with Canadian and Mexican Standards (see Options). WARRANTY — 1-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx 10-3/4 (27.3) 10-1/2 (26.7) For installed Rough Service Product(s), Acuity warrants that, for the lifetime of the product(s), the polycarbonate lens and/or polycarbonate housing will withstand breakage resulting from occasional physical abuse and rough handling (the “Rough Service Warranty”), notwithstanding the vandalism exclusion set forth at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx. Note: Actual performance may differ as a result of end-user environment and application. Specifications subject to change without notice. 6-3/4 (17.1) 3-7/8 (9.8) 7-1/8 (18.1) Steel WeighBackplate t: 4 lbs (1.8 kg) 7-3/4 (19.7) Cast Housing Weight: 8.5 lbs (3.9 kg) Specifications Steel backplate Cast housing Length: 10-1/2 (26.7) 10-3/4 (27.3) Width: 6-3/4 (17.1) 7-1/8 (18.1) Depth: 3-7/8 (9.8) 7-3/4 (19.7) Weight: 3lbs (1.4kg) 4lbs (1.8kg) ORDERING INFORMATION All dimensions are inches (centimeters) unless otherwise indicated. Example: TWL 32TRT 120 LPI Lead times will vary depending on options selected. Consult with your sales representative. TWL Series Wattage/Lamp Voltage Ballast TWL 26TRT 32TRT 42TRT 120 277 MVOLT1 (blank) Options Standard ballast GMF PE CSA NOM Finish Internal slow-blow fuse2 Photoelectric cell2,3 Meets Canadian standards Meets Mexican standards (consult factory) (blank) DNA DBL DMB DWH DSS Lamped Dark bronze Natural aluminum Black Medium bronze White Sandstone LPI L/LP Lamp included as standard Less lamp Accessories: Order as separate catalog number. RK1 PEB1 RK1 PEB1 CSA RK1 PEB2 TWLMB TWLWG TWAWG TWLEP1 TWLEP2 Photocell kit (120V only) Photocell kit (120V only) Photocell kit (277V) Cast aluminum mounting box Wireguard; use with steel backplate4 Wireguard; use with cast housing Extension collar 1-1/2" deep5 Extension collar 2-1/8" deep5 Notes 1 Standard multi-volt electronic ballast (for 32TRT & 42TRT lamps only) capable of operating on any line voltage from 120V to 277V. 2 Not available with MVOLT. 3 Requires cast back box. 4 Not available with cast housing, TWLMB or PE; use TWAWG. 5 120V NPF units only. INDUSTRIALTWL-TRT TWL Triple-Tube Fluorescent Wall-Pack PHOTOMETRICS See www.lithonia.com. Housing Configuration Compact Fluorescent Steel backplale 26TRT ■ Cast housing For wire guard, requires TWAWG ■ ■ ■ ■ ■ ■ 26TRT PE 32TRT ■ 32TRT PE 42TRT ■ 42TRT PE ELECTRICAL CHARACTERISTICS Wattage/ballast Primary voltage Maximum line current (amps) Input watts Power factor % Fluorescent 1-26TRT 120 277 0.22 0.09 26 HPF Fluorescent 1-32TRT 120 277 0.30 0.13 36 HPF Fluorescent 1-42TRT 120 277 0.39 0.17 47 HPF Mounting Height Correction Factor (Multiply the fc level by the correction factor) Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field measurements. Dimensions and specifications on this sheet are based on the most current available data and are subject to change without notice. 10ft. = 0.36 12ft. = 0.25 TWL-TRT INDUSTRIAL: 8ft. = 0.56 One Lithonia Way Conyers, GA 30012 Phone: 800-315-4963 www.lithonia.com © 1993-2016 Acuity Brands Lighting, Inc. All rights reserved. Rev. 07/07/2016