low voltage QL - Series Miniature Circuit Breakers DIN mount (grey body) Dual mount (black body) Dual mount + Auxiliary (black body) Features Applications • • • • • • • • • • • • • • • • • • • • • • • • • • AC Circuit Breaker Hydraulic-Magnetic technology 100% rating capability, independent of ambient temperature One, two and three pole (UL). One, two, three pole and 1+N, 3+N (VDE). VDE and CCC approved, CE certified UL listed (CSA / UL 489) Ratings 0.1 to 25 A Optional Auxiliary Switch / Trip Alarm - factory fitted (6.5 mm wide) Optional Shunt Trip (no approvals) Wide range of time delays and operating currents Precision tripping characteristics Ultra compact – 13 mm wide module Trip indication with mid-trip handle Reset immediately after overload DIN mount product in grey shells Dual mount product in black shells Current limiting capability Ring terminal ready (terminal screw is removable) Suitable to use for electrical isolation Auxiliary Switch,Trip Alarm & Combo: Features • • • • • • AC branch circuit protection Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Power conditioning equipment Optional Accessories • • AC and DC voltages • UL 489 listed (Auxiliary Switch: 6 A 250 V AC, • 0.5 A 80 V DC) • IEC 60947-5-1 approved (Auxiliary Switch: 6 A 240 V AC, 0.5 A 110 V DC; Trip Alarm: 6 A 240 V AC, 0.5 A 110 V DC) • • Factory fitted • Attached to right hand side of Circuit Breaker Auxiliary Switch Auxiliary Switch + Trip Alarm Trip Alarm Handle lock Surface mounting clips Busbar 57 mm Escutcheon blank 57 mm Safety blank Compact 6.5 mm width QL-SERIES-DAT DEC 2014 Data Sheet Page 1 of 8 low voltage QL - Series Miniature Circuit Breakers Technical Data Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Interrupting Capacity Operating Temperature Range Mounting Options Time Delay Curves Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Interrupting Capacity Operating Temperature Range Mounting Options Time Delay Curves 1 1 Pole & 2 Pole Data Sheet Page 2 of 8 IEC / EN 60947-2, VDE 2 240 V AC 3 415 V AC UL 489 1 120 V AC 1 240 V AC 2 120 / 240 V AC 3 240 V AC 25 A 10 kA 25 A 5 kA 0.1 A 25 A 10 kA 20 A 5 kA -40oC to +85oC DIN Rail, Dual mounting (DIN & Mini), surface mounting clip 1, 9, KM, OP CCC 1 2 (1+N) 2 240 V AC 240 V AC 240 V AC 0.1 A 25 A 25 A 25 A 6 kA -40oC to +85oC DIN Rail, Dual mounting (DIN & Mini), surface mounting clip 1, 9, KM, OP Wire Size mm² (IEC) Wire Gauge (UL) Torque (IEC) Torque (UL) 0.75 - 35 mm² 18 – 2 – AWG 2.5 Nm 20 in-lb QL-SERIES-DAT DEC 2014 4 (3+N) 0.1 A 25 A 6 kA -40oC to +85oC DIN Rail, Dual mounting (DIN & Mini), surface mounting clip 1, 9, KM, OP Approvals Number of Poles Operating Voltages Minimum Current Rating Maximum Current Rating Interrupting Capacity Operating Temperature Range Mounting Options Time Delay Curves Breaker QL 2 (1+N) Comments Pozidriv #2 Combi head low voltage QL - Series Miniature Circuit Breakers Long Code Example Code: QL---AT-3(13)-D-KM-15A-------Z Group 1 2 3 4 5 6 7 8 9 10 11 12 QL Frame Switch / Neutral Auxiliary + Trip Alarm Triple pole 13 mm module width DIN Rail Medium delay curve KM 15 A Future use No Shunt Trip Future use Parallel bridged (by customer) Long Code QL - AT 3 (13) D KM 15A - - - Z Group 1: Frame Type Code Description Comments QL 13 mm wide Miniature Circuit Breaker UL 489A, IEC / EN 60947-2,VDE, CE, CCC Requirement Group 2: Code Switch/Neutral Group 3: Auxiliary Group 4: No of Poles Description Comments Not applicable Overload poles do not have any further coding N Neutral Code Description Comments - Not applicable Use this code if no Auxiliary used A Auxiliary Switch (1 x Aux in 1 module) 6.5 mm module fitted on right-hand side T Trip Alarm (1 x Trip Alarm in 1 module) 6.5 mm module fitted on right-hand side AT Auxiliary Switch + Trip Alarm combo (combined in 1 module) 6.5 mm module fitted on right-hand side Code Description Comments 1 Single pole 2 Double pole 3 Triple pole 2 pole or1+N 4 Four pole 3+N only Group 5: Module Width Code Description Comments (13) 13 mm module width 13 mm per pole Group 6: Mounting Code Description Comments D DIN rail mount – 45 mm Escutcheon, grey body DIN mount supplied in grey only DM Dual mount – 57 mm Escutcheon, black body Group 7: Time Delays Code Description Instantaneous Trip Point (x In) Comments 1 Long time delay, high instantaneous trip 10 – 20 Orange handle Dual mount supplied in black only 9 Long time delay 7 – 12 White handle KM Medium time delay 6 – 12 White handle OP Instantaneous None White handle Group 8: Current Ratings Code / Description Comments Ratings available vary depending on certification 0.1, 0.2, 0.3, 0.5, 1, 2, 3, 4, 5, 6, 7, 8 ,9, 10, 12, 15, 16, 20, 25 A * Other ratings are available as special orders. Check availability. For future use (-) Group 9: Code Group 10: Shunt Trip Code Description Comments - Not applicable Use this code if no Shunt Trip is used V0 100 – 480 V AC Fly leads (approximately 60 mm long) V5 100 – 480 V AC Internally connected (not certified, only offered as special order) Other voltages are available as special orders. Check availability. Group 11 Code Group 12: Special Termination Code Description Comments - Not applicable Use this code if no special terminations are used For future use (-) P Plug-in Z Bridged unit (bridge to be fitted by customer) ZL Bridged unit (factory fitted) For options not listed, please contact CBI for assistance QL-SERIES-DAT DEC 2014 Data Sheet Page 3 of 8 low voltage QL - Series Miniature Circuit Breakers Time Delay Curves 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE 1 Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 4000 5000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Maximum % Rated Current 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE 9 Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 % Rated Current Data Sheet Page 4 of 8 QL-SERIES-DAT DEC 2014 4000 5000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Maximum low voltage QL - Series Miniature Circuit Breakers Time Delay Curves 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE KM Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 5000 4000 3000 2000 1500 1000 500 400 300 200 150 100 0.001 125 Maximum % Rated Current 1500 100000 OPERATING CHARACTERISTICS 10000 CURVE OP Tripping Time (Seconds) 1000 100 10 1 0.1 Maximum 0.01 5000 4000 3000 2000 2500 1500 1000 500 400 300 200 130 100 105 0.001 150 Maximum % Rated Current * The published time delay curves are generated at 30oC ambient temperature with the Circuit Breaker mounted in the up-right position. The “must hold”, “must trip” and “instantaneous trip” current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. QL-SERIES-DAT DEC 2014 Data Sheet Page 5 of 8 low voltage QL - Series Miniature Circuit Breakers Internal Impedance vs Current Rating Q-Range impedance values 10,000 Impedance (m Ω ) 1,000 100 10 Maximum 1 0.1 Maximum 0 5 10 15 20 25 30 35 Amp rating 40 45 Auxiliary Switch / Trip Alarm Auxiliary available (6.5 mm module width) to match the unit to which it is attached. Available types as listed in Group 3: • • • Type T - Trip Alarm as shown in outline drawings (fitted on a Dual mount product) Type AT - Auxiliary Switch + Trip Alarm (as shown) Type A - Auxiliary Switch Data Sheet Page 6 of 8 QL-SERIES-DAT DEC 2014 50 55 60 65 low voltage QL - Series Miniature Circuit Breakers 57.0 97.2 Typical outline of Auxiliary Switch / Trip Alarm Typical outline for an Auxiliary module attached to a Dual mount single pole Circuit Breaker All dimensions in mm Tolerance ± 0.2 unless otherwise specified All widths are maximum 69.8 35.5 19.3 AUXILIARY/ TRIP ALARM (AT) 18.0 6.0 Circuit Diagrams Trip Alarm Switch 16 18 11 12 15 16 15 18 16 11 12 Auxiliary Switch 14 A005438 S Q-AUX V D E TEST BUTTON (not on Auxiliary) Uimp = 2.5kV Icw = 0.1kA UTIL. CAT. AC12/DC12 POLLUTION DEGREE 3 RoHS 15 TRIP ALARM SWITCH AUXILIARY SWITCH 110 VDC : 0,5A 110 VDC : 0,5A 240 VAC : 6A 240 VAC : 6A EN/IEC 60947-5-1 18 11 12 14 14 11.7 6.5 18.0 37.8 1.4 0.8 0.5 2.3 6.8 45° 2.80 CONNECTING TERMINALS DETAIL (COMMON TO ALL) QL-SERIES-DAT DEC 2014 Data Sheet Page 7 of 8 low voltage QL - Series Miniature Circuit Breakers Outline Dimensions: Dual mount 69.1 2.720 61.0 13.0 2.400 19.6 1.024 39.0 1.536 2.801 71.2 3.827 97.2 (Ref) 2.244 57.0 3.244 0.772 82.4 26.0 0.512 19.6 13.0 0.772 5.0 0.512 45.0 0.197 1.772 All dimensions in mm [ inch ] Tolerance ± 0.2 [ 0.008 ] unless otherwise specified All widths are maximum 64.8 2.551 Outline Dimensions: DIN mount 68.1 2.681 60.0 2.362 18.6 1.024 39.0 1.536 2.803 3.827 97.2 (Ref) 1.772 45.0 71.2 0.512 3.244 82.4 26.0 13.0 0.732 18.6 13.0 0.732 5.0 0.512 44.0 0.197 1.732 63.8 2.512 All dimensions in mm [ inch ] Tolerance ± 0.2 [ 0.008 ] unless otherwise specified All widths are maximum Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 90 Fairbank Road Clayton South Melbourne Victoria 3169 Australia Tel: + 61 39590 3500 Fax: +61 3 9551 1051 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au Data Sheet Page 8 of 8 QL-SERIES-DAT DEC 2014 SOUTH AFRICA CBI-electric: low voltage Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com A member of the Group